HomeMy WebLinkAboutLA206236 - Assessment_Greenway_Solar_21199_Ixonia_Ln_9.6.2022
Complete Building Solutions ▪ 2525 Nevada Ave North ▪ Suite 302 ▪ Golden Valley, MN 55427 1
September 8, 2022
Greenway Solar c/o Guido email: guido.palma@greenwaysolar.org
21199 Ixonia Ln,
Lakeville, MN
Re: 21199 Ixonia Ln, Lakeville, MN
Dear Greenway Solar;
On Thursday, September 1st, 2022, an engineer from Complete Building Solutions (CBS) was
brought onsite. Our assessment and analysis are summarized below.
A non-intrusive investigation was performed, as many of the structural members were hidden,
some assumptions based on traditional construction methods and visible members were taken.
Background Summary
BS was brought onsite to assess the existing roof and proposed solar panels.
Structural Assessment of Building
Conclusion:
In my professional opinion:
The existing roof is a truss system. So long as the installers follow the installation instructions
from the solar manufacturer, this roof trusses have sufficient excess capacity to support the
solar panel arrays on the multiple roof slopes. No additional reinforcement is required.
If you have any questions, please feel free to contact Complete Building Solutions at
admin@cbsmn.com to schedule additional time.
Yours truly,
Stephen Hammill, P. E.
9/8/2022
9/8/2022
Concept Approval ONLYSubject to Field Inspection
Inspector Date
2020
MN Bldg
Code
09/09/2022dpfannenstein
Provide copy of city
approved plans on the job
site for the inspector