Loading...
HomeMy WebLinkAboutLA201707 PlansEXIST'G ROOF STRUCTURE 4:12 NEW ROOF STRUCTURE REMOVE EXIST'G HIP SET ADD NEW ROOF FRAMING TO TIE IN NEW ADDITION 12 6 24" O.H. GARAGE ADDITION FRONT ELEVATION SCALE: 1/4" = 1'-0" 1 1 EXIST'G BRICK FIREPLACE CHASE NEW BOARD & BATTEN ALUM. SOFFIT & FASCIA 6" TRIM BRDS. NEW LAP SIDING 8" TRIM BRD. LEFT ELEVATION SCALE: 1/8" = 1'-0" 2 1 NEW LAP SIDING 6:12 6:12 EXIST'G ROOF EXIST'G BRICK F.P. CHASE NEW ASPHALT SHINGLES NEW STONE VENEER REAR ELEVATION SCALE: 1/8" = 1'-0" 3 1 NEW LAP SIDING 12 6 EXIST'G ROOF STRUCTURE 4:12 NEW ROOF STRUCTURE -----MILINER RESIDENCEPROJECT:BONUS ROOMTOTALUPPER FLOORMAIN FLOORLOWER FLOORFINISHED SQ.FT.PAGE#:REVISION RECORD:16274 GANNON AVE WROSEMOUNT, MN 55068119/22/22To the best of my knowledge these plans are drawn to comply with owner'sand/ or builder's specifications and any changes made on them after printsare made will be done at the owner's and / or builder's expense andresponsibility. The contractor shall verify all dimensions and encloseddrawing. JRO Drafting & Design is not liable for errors once constructionhas begun. While every effort has been made in the preparation of this planto avoid mistakes, the maker can not guarantee against human error. Thecontractor of the job must check all dimensions and other details prior toconstruction and be solely responsible thereafter.DATE:4-24-225-2-229-22-22Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 09/23/2022dmathews REVISED PLANS Original permit plans approved 5/6/22, revised beam at connection to existing. 17'-9 1/4"16'-4"42'-0"16'-4"12'-1 3/4" 2'-1"12'-2"2'-1"18'-0"2'-0"4'-5"9'-2"4'-5"DEMO EXIST'G CURB @ FDN WALL WALL BELOW SLAB TO REMAIN FOUNDATION - GARAGE ADDITION SCALE: 1/4" = 1'-0" 1 2 UNEXCAVATED 1crs. 6" CMU BLOCK ON 5crs. 8" CMU BLOCK ON 16" x 8" CONT. CONC. FTG. REBAR PER CODE 1crs. 6" CMU BLOCK ON 5crs. 8" CMU BLOCK ON 16" x 8" CONT. CONC. FTG. REBAR PER CODE WALL LEGEND = EXISTING FRAMING WALL = NEW FRAMING WALL = EXISTING CONCRETE WALL = NEW CONCRETE WALL = DEMO'D WALL EXISTING FOUNDATION EXISTING FOUNDATIONM.O. FOR 9' O.H. DOOR ABOVEM.O. FOR 12' O.H. DOOR ABOVE -----MILINER RESIDENCEPROJECT:BONUS ROOMTOTALUPPER FLOORMAIN FLOORLOWER FLOORFINISHED SQ.FT.PAGE#:REVISION RECORD:16274 GANNON AVE WROSEMOUNT, MN 55068229/22/22To the best of my knowledge these plans are drawn to comply with owner'sand/ or builder's specifications and any changes made on them after printsare made will be done at the owner's and / or builder's expense andresponsibility. The contractor shall verify all dimensions and encloseddrawing. JRO Drafting & Design is not liable for errors once constructionhas begun. While every effort has been made in the preparation of this planto avoid mistakes, the maker can not guarantee against human error. Thecontractor of the job must check all dimensions and other details prior toconstruction and be solely responsible thereafter.DATE:4-24-225-2-229-22-22 EXIST'G 3068NEW 9' x 7' O.H. DOOREXIST'G 2668EXIST'G 2668 NEW 12' x 8' O.H. DOORRE-USE EXIST'G 9' x 7' O.H. DOOR HERE5'-7 1/2"12'-1 3/4"16'-4"2'-0"22'-0"18'-0"3'-1"7'-10 3/4" 1'-11 1/2"21'-4"42'-0"4'-6"12'-0"18'-0"12'-0"16'-4"17'-9 1/4" 2'-1"12'-2"2'-1"3'-11"2'-0"4'-10"7'-7 3/4" 8'-2"8'-2"18'-0"9'-0"9'-0"EXIST'G GARAG E EXIST'G HDR2-11 7/8" LVL2-2x12 EXIST'G 2-PLY GIRDEREXIST'G ROOF TRUSSESNEW ROOF TRUSSES DEMO EXIST'G EXTERIOR WALL DEMO EXIST'G MONO TRUSSES TO THIS SIDE OF GIRDER 672 SQ FT GARAGE ADDITION SCALE: 1/4" = 1'-0" 1 348" x 24" PIC2-2x102-2x1048" x 24" PICGARAGE ADDITION SPACING PER MANUF. CONC. FLR SLOPED TO O.H. DOORS OPT. FLOOR DRAIN WALL LEGEND = EXISTING FRAMING WALL = NEW FRAMING WALL = EXISTING CONCRETE WALL = NEW CONCRETE WALL = DEMO'D WALL CONC. APRON CONC. APRON NEW CONC STEP NEW CONC STEPSTONE VENEER STONE VENEERSTONE RETURN1 2 1 2 2-2x10 48" x 24" PIC NEW ROOF TRUSSESMATCH EXIST'GSITE VERIFYNEW 3-ply 14" LVL ROOF BEAMNEW ROOF TRUSSES SPACING PER MANUF.7'-0" HEAD HGT.7'-0" HEAD HGT.7'-0" HEAD HGT.-----MILINER RESIDENCEPROJECT:BONUS ROOMTOTALUPPER FLOORMAIN FLOORLOWER FLOORFINISHED SQ.FT.PAGE#:REVISION RECORD:16274 GANNON AVE WROSEMOUNT, MN 55068339/22/22To the best of my knowledge these plans are drawn to comply with owner'sand/ or builder's specifications and any changes made on them after printsare made will be done at the owner's and / or builder's expense andresponsibility. The contractor shall verify all dimensions and encloseddrawing. JRO Drafting & Design is not liable for errors once constructionhas begun. While every effort has been made in the preparation of this planto avoid mistakes, the maker can not guarantee against human error. Thecontractor of the job must check all dimensions and other details prior toconstruction and be solely responsible thereafter.DATE:4-24-225-2-229-22-22 ASPHALT SHINGLES ON 15# ROOF FELT 1/2" O.S.B. SHEATHING w/ H-CLIPS INSTALL WIND WASH & 4' OF ICE & WATER SHIELD VENT 1/300 OF ATTIC 50% AT RIDGE 50% AT SOFFIT 7'-0"EXIST'G 2-PLY GIRDER EXIST'G ROOF NEW ROOF GIRDER DEMO EXIST'G EXTERIOR WALL & CONC. CURB 4:12 PITCH - SITE VERIFY 12 6 1crs. 6" CMU BLOCK ON 5crs. 8" CMU BLOCK ON 16" x 8" CONT. CONC. FTG. REBAR PER CODE R-49 CEILING INSULATION 4mil VAPOR BARRIER 5/8" GYP. BOARD MIN. 1" AIR SPACE @ EAVE R-49 CEILING INSULATION 4mil VAPOR BARRIER 5/8" GYP. BOARD MIN. 1" AIR SPACE @ EAVE EXIST'G GARAGEGARAGE ADDT'N EXIST'G HOUSE 1/2" GYP. BOARD 4mil. VAPOR BARRIER 2x4 STUDS @ 16" O.C. R-13 BATT INSULATION 7/16" OSB SHEATHING SIDING PER ELEVATION NEW CONC. FLR SLOPED TO OH DOORS NEW CONC. FLR SLOPED TO OH DOORS EXIST'G FDN WALLS FTG DEPTH UNKNOWN ENGINEERED ROOF TRUSSES @ 24" O.C. BY MANUFACTURER 24" O.H.WDW HGT.BUILDING SECTION SCALE: 1/4" = 1'-0" 1 4 NEW 3-PLY 14" LVL ROOF BEAM NOTE: ALL GIRDERS & BEAMS RELATIVE TO THE ROOF STRUCTURE ARE TO BE ENG. & DESIGNED BY THE TRUSS MNF. REFER TO THE SPEC/LAYOUT SHEETS PROVIDED BY THE TRUSS MNF. 2'1'2' 2'2'1'2'EXIST'G4:12EXIST'G4:12NEW 4:12NEW 4:126:12 6:12 6:12 6:12 6:12 6:12 ROOF PLAN SCALE: 1/8" = 1'-0" 2 4 EXIST'G 4:12 EXIST'G 4:12 EXIST'G BRICKF.P. CHASE10'13.6' 4 2.0' 2.0'16.3'16.3' 18 .0'GARAGE ADDT'N 0.3'-----MILINER RESIDENCEPROJECT:BONUS ROOMTOTALUPPER FLOORMAIN FLOORLOWER FLOORFINISHED SQ.FT.PAGE#:REVISION RECORD:16274 GANNON AVE WROSEMOUNT, MN 55068449/22/22To the best of my knowledge these plans are drawn to comply with owner'sand/ or builder's specifications and any changes made on them after printsare made will be done at the owner's and / or builder's expense andresponsibility. The contractor shall verify all dimensions and encloseddrawing. JRO Drafting & Design is not liable for errors once constructionhas begun. While every effort has been made in the preparation of this planto avoid mistakes, the maker can not guarantee against human error. Thecontractor of the job must check all dimensions and other details prior toconstruction and be solely responsible thereafter.DATE:4-24-225-2-229-22-22 9'-9 3/8" 1'-1 1/2" 8'-7 7/8" FRONT ELEVATION HEADER PER PLAN - MIN. 3" x 11.25" FASTEN SHEATHING TO HEADER WITH 8d COMMON NAILS IN 3" GRID PATTERN AND 3" O.C. FASTEN HEADER TO KING STUD WITH (6) 16d SINKER NAILSPONYWALLHGT.MIN. LENGTH BASED ON 6:1HEIGHT TO LENGTH RATIO.FOR EXAMPLE: 16" MIN.FOR 8' HEIGHT. 1'-11" WOOD STRUCTURAL PANEL STRENGTH AXIS FOR A PANEL SPICE (IF NEEDED),PANEL EDGES SHALL BE BLOCKED,AND OCCUR WITHIN MIDDLE 24"OF WALL HEIGHT. ONE ROW OF3" NAILING IS REQUIRED AT EACH PANEL EDGE. MIN. (2) 2x4 TYP. SIMPSON STHD-14 4200# HOLD DOWN STRAP 2 @ EACH SIDE CONC. FOUNDATION PER PLAN10'-0" MAX. HEIGHT12'-0" MAX. TOTAL WALL HEIGHTSIDE ELEVATION MIN. 1000LB. TENSION STRAP CENTERED AT BOTTOM OF HEADER SHEATHING FILLER IF NEEDED WOOD STRUCTURAL PANEL MUST BE CONTINUOUS FROM TOP OF WALL TO BOTTOM OF WALL,OR FROM TOP OF WALL TO PERMITED SPLICE AREA. 3/8" MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING CORNER DETAIL 3/8" MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING FASTEN SHEATHING WITH 8d COMMON NAILS IN 3" GRID PATTERN AND 3" O.C. GARAGE PORTAL FRAME SCALE: 1/2" = 1'-0" 1 5 5'-11 3/8" 9'-9 3/8" FRONT ELEVATION HEADER PER PLAN - MIN. 3" x 11.25" FASTEN SHEATHING TO HEADER WITH 8d COMMON NAILS IN 3" GRID PATTERN AND 3" O.C. FASTEN HEADER TO KING STUD WITH (6) 16d SINKER NAILSPONYWALLHGT.MIN. LENGTH BASED ON 6:1HEIGHT TO LENGTH RATIO.FOR EXAMPLE: 16" MIN.FOR 8' HEIGHT. 1'-11" WOOD STRUCTURAL PANEL STRENGTH AXIS FOR A PANEL SPICE (IF NEEDED),PANEL EDGES SHALL BE BLOCKED,AND OCCUR WITHIN MIDDLE 24"OF WALL HEIGHT. ONE ROW OF3" NAILING IS REQUIRED AT EACH PANEL EDGE. MIN. (2) 2x4 TYP. SIMPSON STHD-14 4200# HOLD DOWN STRAP 2 @ EACH SIDE CONC. FOUNDATION PER PLAN10'-0" MAX. HEIGHT12'-0" MAX. TOTAL WALL HEIGHTSIDE ELEVATION MIN. 1000LB. TENSION STRAP CENTERED AT BOTTOM OF HEADER SHEATHING FILLER IF NEEDED WOOD STRUCTURAL PANEL MUST BE CONTINUOUS FROM TOP OF WALL TO BOTTOM OF WALL,OR FROM TOP OF WALL TO PERMITED SPLICE AREA. 3/8" MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING CORNER DETAIL 3/8" MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING FASTEN SHEATHING WITH 8d COMMON NAILS IN 3" GRID PATTERN AND 3" O.C.-----MILINER RESIDENCEPROJECT:BONUS ROOMTOTALUPPER FLOORMAIN FLOORLOWER FLOORFINISHED SQ.FT.PAGE#:REVISION RECORD:16274 GANNON AVE WROSEMOUNT, MN 55068559/22/22To the best of my knowledge these plans are drawn to comply with owner'sand/ or builder's specifications and any changes made on them after printsare made will be done at the owner's and / or builder's expense andresponsibility. The contractor shall verify all dimensions and encloseddrawing. JRO Drafting & Design is not liable for errors once constructionhas begun. While every effort has been made in the preparation of this planto avoid mistakes, the maker can not guarantee against human error. Thecontractor of the job must check all dimensions and other details prior toconstruction and be solely responsible thereafter.DATE:4-24-225-2-229-22-22