Loading...
HomeMy WebLinkAboutLA206743-APPROVED - Rindels Engineering Letter FlatBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2  'RPXVVWUXFWXUDO#JPDLOFRP dŽ͗ ůƵĞZĂǀĞŶ^ŽůĂƌ ϭϰϬϯEŽƌƚŚZĞƐĞĂƌĐŚtĂLJ͕ƵŝůĚŝŶŐ: KƌĞŵ͕hd͘ϴϰϬϵϳ ^ƵďũĞĐƚ͗ ĞƌƚŝĨŝĐĂƚŝŽŶ>ĞƚƚĞƌ ZŝŶĚĞůƐZĞƐŝĚĞŶĐĞ ϭϭϮϮϬ<ĞŶŽƌĂtĂLJ >ĂŬĞǀŝůůĞ͕DE͘ϱϱϬϰϰ dŽtŚŽŵ/ƚDĂLJŽŶĐĞƌŶ͕ ĞƐŝŐŶƌŝƚĞƌŝĂ͗ භ ƉƉůŝĐĂďůĞŽĚĞƐсϮϬϭϴ/ͬ/Z͕^ϳͲϭϲ භ ZŽŽĨĞĂĚ>ŽĂĚсϳƉƐĨ;DWϭͿ භ ZŽŽĨ>ŝǀĞ>ŽĂĚсϮϬƉƐĨ භ tŝŶĚ^ƉĞĞĚсϭϭϱŵƉŚ;sƵůƚͿ͕džƉŽƐƵƌĞ භ භ ^ŝŶĐĞƌĞůLJ͕ :ŽŚŶĂůǀĞƌƚ͕W͘͘ WƌŽũĞĐƚŶŐŝŶĞĞƌ ^ĞƉƚĞŵďĞƌϭϵ͕ϮϬϮϮ dŚĞƌŽŽĨƐƚƌƵĐƚƵƌĞŽĨ;DWϭͿĐŽŶƐŝƐƚƐŽĨĐŽŵƉŽƐŝƚŝŽŶƐŚŝŶŐůĞŽŶƌŽŽĨƉůLJǁŽŽĚƚŚĂƚŝƐƐƵƉƉŽƌƚĞĚďLJƉƌĞͲŵĂŶƵĨĂĐƚƵƌĞĚƚƌƵƐƐĞƐƚŚĂƚ ĂƌĞƐƉĂĐĞĚĂƚΛϮϰΗŽ͘Đ͘͘dŚĞƚŽƉĐŚŽƌĚƐ͕ƐůŽƉĞĚĂƚϯϬĚĞŐƌĞĞƐ͕ĂƌĞϮdžϰƐĞĐƚŝŽŶƐ͕ƚŚĞďŽƚƚŽŵĐŚŽƌĚƐĂƌĞϮdžϰƐĞĐƚŝŽŶƐĂŶĚƚŚĞǁĞď ŵĞŵďĞƌƐĂƌĞϮdžϰƐĞĐƚŝŽŶƐ͘dŚĞƚƌƵƐƐŵĞŵďĞƌƐĂƌĞĐŽŶŶĞĐƚĞĚďLJƐƚĞĞůŐƵƐƐĞƚƉůĂƚĞƐ͘dŚĞŵĂdžƵŶƐƵƉƉŽƌƚĞĚƉƌŽũĞĐƚĞĚŚŽƌŝnjŽŶƚĂů ƚŽƉĐŚŽƌĚƐƉĂŶŝƐĂƉƉƌŽdžŝŵĂƚĞůLJϲΖͲϬΖΖ͘ dŚĞĞdžŝƐƚŝŶŐƌŽŽĨĨƌĂŵŝŶŐƐLJƐƚĞŵŽĨ;DWϭͿŝƐũƵĚŐĞĚƚŽďĞĂĚĞƋƵĂƚĞƚŽǁŝƚŚƐƚĂŶĚƚŚĞůŽĂĚŝŶŐŝŵƉŽƐĞĚďLJƚŚĞŝŶƐƚĂůůĂƚŝŽŶŽĨƚŚĞ ƐŽůĂƌƉĂŶĞůƐ͘EŽƌĞŝŶĨŽƌĐĞŵĞŶƚŝƐŶĞĐĞƐƐĂƌLJ͘ 'ƌŽƵŶĚ^ŶŽǁ>ŽĂĚсϱϬƉƐĨͲZŽŽĨ^ŶŽǁ>ŽĂĚсϯϱƉƐĨ dŚĞƐƉĂĐŝŶŐŽĨƚŚĞƐŽůĂƌƐƚĂŶĚŽĨĨƐƐŚŽƵůĚďĞŬĞƉƚĂƚϰϴΗŽ͘Đ͘ĨŽƌůĂŶĚƐĐĂƉĞĂŶĚϮϰΗŽ͘Đ͘ĨŽƌƉŽƌƚƌĂŝƚŽƌŝĞŶƚĂƚŝŽŶ͕ǁŝƚŚĂƐƚĂŐŐĞƌĞĚ ƉĂƚƚĞƌŶƚŽĞŶƐƵƌĞƉƌŽƉĞƌĚŝƐƚƌŝďƵƚŝŽŶŽĨůŽĂĚƐ͘ ũŽďƐŝƚĞŽďƐĞƌǀĂƚŝŽŶŽĨƚŚĞĐŽŶĚŝƚŝŽŶŽĨƚŚĞĞdžŝƐƚŝŶŐĨƌĂŵŝŶŐƐLJƐƚĞŵǁĂƐƉĞƌĨŽƌŵĞĚďLJĂŶĂƵĚŝƚƚĞĂŵŽĨůƵĞZĂǀĞŶ^ŽůĂƌĂƐĂ ƌĞƋƵĞƐƚĨƌŽŵŽŵƵƐ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌŝŶŐ͘ůůƌĞǀŝĞǁŝƐďĂƐĞĚŽŶƚŚĞƐĞŽďƐĞƌǀĂƚŝŽŶƐĂŶĚƚŚĞĚĞƐŝŐŶĐƌŝƚĞƌŝĂůŝƐƚĞĚďĞůŽǁĂŶĚ ŽŶůLJĚĞĞŵĞĚǀĂůŝĚŝĨƉƌŽǀŝĚĞĚŝŶĨŽƌŵĂƚŝŽŶŝƐƚƌƵĞĂŶĚĂĐĐƵƌĂƚĞ͘ KŶƚŚĞĂďŽǀĞƌĞĨĞƌĞŶĐĞĚƉƌŽũĞĐƚ͕ƚŚĞƌŽŽĨƐƚƌƵĐƚƵƌĂůĨƌĂŵŝŶŐŚĂƐďĞĞŶƌĞǀŝĞǁĞĚĨŽƌĂĚĚŝƚŝŽŶĂůůŽĂĚŝŶŐĚƵĞƚŽƚŚĞŝŶƐƚĂůůĂƚŝŽŶŽĨ ƚŚĞƐŽůĂƌWsĂĚĚŝƚŝŽŶƚŽƚŚĞƌŽŽĨ͘dŚĞƐƚƌƵĐƚƵƌĂůƌĞǀŝĞǁŽŶůLJĂƉƉůŝĞƐƚŽƚŚĞƐĞĐƚŝŽŶŽĨƚŚĞƌŽŽĨƚŚĂƚŝƐĚŝƌĞĐƚůLJƐƵƉƉŽƌƚŝŶŐƚŚĞƐŽůĂƌ WsƐLJƐƚĞŵĂŶĚŝƚƐƐƵƉƉŽƌƚŝŶŐĞůĞŵĞŶƚƐ͘dŚĞŽďƐĞƌǀĞĚƌŽŽĨĨƌĂŵŝŶŐŝƐĚĞƐĐƌŝďĞĚďĞůŽǁ͘/ĨĨŝĞůĚĐŽŶĚŝƚŝŽŶƐĚŝĨĨĞƌ͕ĐŽŶƚƌĂĐƚŽƌƚŽ ŶŽƚŝĨLJĞŶŐŝŶĞĞƌƉƌŝŽƌƚŽƐƚĂƌƚŝŶŐĐŽŶƐƚƌƵĐƚŝŽŶ͘ dŚĞƐĐŽƉĞŽĨƚŚŝƐƌĞƉŽƌƚŝƐƐƚƌŝĐƚůLJůŝŵŝƚĞĚƚŽĂŶĞǀĂůƵĂƚŝŽŶŽĨƚŚĞĨĂƐƚĞŶĞƌĂƚƚĂĐŚŵĞŶƚ͕ƵŶĚĞƌůLJŝŶŐĨƌĂŵŝŶŐĂŶĚƐƵƉƉŽƌƚŝŶŐ ƐƚƌƵĐƚƵƌĞŽŶůLJ͘dŚĞĂƚƚĂĐŚŵĞŶƚΖƐƚŽƚŚĞĞdžŝƐƚŝŶŐƐƚƌƵĐƚƵƌĞĂƌĞƌĞƋƵŝƌĞĚƚŽďĞŝŶĂƐƚĂŐŐĞƌĞĚƉĂƚƚĞƌŶƚŽĞŶƐƵƌĞƉƌŽƉĞƌĚŝƐƚƌŝďƵƚŝŽŶ ŽĨůŽĂĚŝŶŐ͘ůůƉĂŶĞůƐ͕ƌĂĐŬŝŶŐĂŶĚŚĂƌĚǁĂƌĞƐŚĂůůďĞŝŶƐƚĂůůĞĚƉĞƌŵĂŶƵĨĂĐƚƵƌĞƌƐƉĞĐŝĨŝĐĂƚŝŽŶƐĂŶĚǁŝƚŚŝŶƐƉĞĐŝĨŝĞĚĚĞƐŝŐŶ ůŝŵŝƚĂƚŝŽŶƐ͘ůůǁĂƚĞƌƉƌŽŽĨŝŶŐƐŚĂůůďĞƉƌŽǀŝĚĞĚďLJƚŚĞŵĂŶƵĨĂĐƚƵƌĞƌ͘ŽŵƵƐ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌŝŶŐĂƐƐƵŵĞƐŶŽƌĞƐƉŽŶƐŝďŝůŝƚLJĨŽƌ ŵŝƐƵƐĞŽƌŝŵƉƌŽƉĞƌŝŶƐƚĂůůĂƚŝŽŶŽĨƚŚĞƐŽůĂƌWsƉĂŶĞůƐŽƌƌĂĐŬŝŶŐ͘ WůĞĂƐĞĐŽŶƚĂĐƚŵĞǁŝƚŚĂŶLJĨƵƌƚŚĞƌƋƵĞƐƚŝŽŶƐŽƌĐŽŶĐĞƌŶƐƌĞŐĂƌĚŝŶŐƚŚŝƐƉƌŽũĞĐƚ͘ EŽƚĞ͗^ĞŝƐŵŝĐĐŚĞĐŬŝƐŶŽƚƌĞƋƵŝƌĞĚƐŝŶĐĞ^Ɛф͘ϰŐĂŶĚ^ĞŝƐŵŝĐĞƐŝŐŶĂƚĞŐŽƌLJ;^Ϳф ƚƚĂĐŚŵĞŶƚ͗ϭͲϱͬϭϲĚŝĂ͘ůĂŐƐĐƌĞǁǁŝƚŚϮ͘ϱŝŶĐŚŵŝŶ͘ĞŵďĞĚŵĞŶƚ ĚĞƉƚŚ͕ĂƚƐƉĂĐŝŶŐƐŚŽǁŶĂďŽǀĞ͘ 5LQGHOV/DNHYLOOH01 I hereby certify that this plan, specification or report was prepared by meor under my direct supervision and that I am a duly Licensed ProfessionalEngineer under the laws of the State of Minnesota.John A. Calvert,License No. 52823 Expiration Date: 30-June-2024 Digitally signed by John A. Calvert Date: 2022.09.19 10:11:09 -06'00' Provide copy of city approved plans on the job site for the inspector Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 09/26/2022dpfannenstein ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2  'RPXVVWUXFWXUDO#JPDLOFRP 50 psf (ASCE7 - Eq 7-1) 1 (ASCE7 - Table 7-2) 1 (ASCE7 - Table 7-3) 1 35.0 psf (ASCE7 - Eq 7-2) 1 35.0 psf 3.46 psf 3.0 psf 2.00 ft 6.08 ft 12.17 sft 37 lb 4.00 2.00 0.73 0.00 (Ceiling Not Vaulted) 0.27 7.0 psf 8.1 psf *UDYLW\/RDGLQJ PV System Weight Weight of PV System (Per Blue Raven Solar) X Standoff Spacing = Y Standoff Spacing = Note: PV standoffs are staggered to ensure proper distribution of loading 2x4 Top Chords @ 24"o.c. I = Importance Factor = Cs = Slope Factor = Standoff Tributary Area = ps = Cspf ps = Sloped Roof Snow Load = pf = Flat Roof Snow Load = DL Adjusted to 30 Degree Slope Roof Snow Load Calculations pg = Ground Snow Load = Ce = Exposure Factor = pf = 0.7 CeCtI pg Ct = Thermal Factor = Roof Live Load = 20 psf Roof Plywood Roof Dead Load (MP1) Composition Shingle Note: Roof live load is removed in area's covered by PV array. DL Adjusted to 30 Degree Slope Point Loads of Standoffs Miscellaneous Vaulted Ceiling Total Roof DL (MP1) PV Dead Load = 3 psf (Per Blue Raven Solar) 5LQGHOV/DNHYLOOH01 BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2  'RPXVVWUXFWXUDO#JPDLOFRP 115 mph C Gable Roof 30 degrees 20 ft 21.3 ft 0 ft (Eq. 26.10-1) 0.90 (Table 30.3-1) 1.00 (Fig. 26.8-1) 0.85 (Table 26.6-1) 1.00 115 mph (Fig. 26.5-1A) II (Table 1.5-1) qh = 25.95 Zone 1 Zone 2 Zone 3 Positive ya =0.77 0.80 0.80 0.77 GCp =   (Fig. 30.3) Uplift Pressure =SVI SVI SVI SVI (T ASD Uplift Pressure =SVI SVI SVI SVI X Standoff Spacing = 2.00 2.00 1.33 Y Standoff Spacing = 6.08 3.04166667 3.04166667 Tributary Area = 12.17 6.08 4.06 Dead Load on attachment = 37 lb 18 lb 12 lb Footing Uplift (0.6D+0.6W) = -229 lb -141 lb -139 lb Zone 1 Zone 2 Zone 3 Positive ya =0.75 0.80 0.80 0.75 GCp =   (Fig. 30.3) Uplift Pressure =SVI SVI SVI SVI (T ASD Uplift Pressure (0.6W)=SVI SVI SVI SVI X Standoff Spacing = 4.00 4.00 2.67 Y Standoff Spacing = 3.50 1.75 1.75 Tributary Area = 14.00 7.00 4.67 Dead Load on attachment = 42.00 21.00 14.00 Footing Uplift (0.6D+0.6W) = -246 lb -162 lb -156 lb -246 lb 450 lb Therefore, OK Fastener =1 - 5/16" dia. lag Number of Fasteners = 1 Embedment Depth = 2.5 Pullout Capacity Per Inch = 250 lb Fastener Capacity = 625 lb w/ F.S. of 1.5 & DOL of 1.6= 667 lb Therefore, OK Fastener Capacity Check Mean Roof Height Ground Elevation Kd (Wind Directionality Factor) = 667.2 lb capacity > 246 lb demand Ke (Ground Elevation Factor) = V (Design Wind Speed) = Risk Category = Standoff Uplift Calculations-Portrait Standoff Uplift Calculations-Landscape Standoff Uplift Check Standoff Uplift Capacity = 450 lb capacity > 246 lb demand :LQG&DOFXODWLRQV Maximum Design Uplift = Design Wind Pressure Calculations qh = 0.00256 * Kz * Kzt * Kd * Ke * V^2 Kz (Exposure Coefficient) = Kzt (topographic factor) = Wind Speed Exposure Category Roof Shape Roof Slope Effective Wind Area WĞƌ^ϳͲϭϲŽŵƉŽŶĞŶƚƐĂŶĚůĂĚĚŝŶŐ Input Variables 5LQGHOV/DNHYLOOH01 BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2  'RPXVVWUXFWXUDO#JPDLOFRP 03 PASS Dead Load 8.1 psf PV Load 3.5 psf Snow Load 35.0 psf Governing Load Combo = DL + SL Total Load 46.5 psf Fb (psi) = f'b x Cd x Cf x Cr (NDS Table 4.3.1) 900 x 1.15 x 1.5 x 1.15 Allowed Bending Stress = 1785.3 psi (wL^2) / 8 = 418.923 ft# = 5027.077 in# Actual Bending Stress = (Maximum Moment) / S = 1641.5 psi L/180 (E = 1600000 psi Per NDS) = 0.4 in Deflection Criteria Based on = (w*L^4) / (185*E*I) = = L/546 > L/180 Therefore OK Allowed Deflection (Live Load) =L/240 0.3 in (w*L^4) / (185*E*I) L/728 > L/240 Therefore OK Member Area = Fv (psi) = 180 psi (NDS Table 4A) Allowed Shear = Fv * A =Max Shear (V) = w * L / 2 =279 lb )UDPLQJ&KHFN 5.3 in^2 Check Shear w = 93 plf 2x4 Top Chords @ 24"o.c. Member Span = 6' - 0" 945 lb Allowed > Actual -- 29.6% Stressed -- Therefore, OK DF#2 Member Spacing @ 24"o.c. Maximum Moment = Check Deflection I (in^4) 5.36 Lumber Sp/Gr Actual Deflection (Live Load)= Allowed Deflection (Total Load) = Actual Deflection (Total Load) = Allowed > Actual -- 92% Stressed -- Therefore, OK Member Properties Member Size 2x4 S (in^3) 3.06 0.099 in Continuous Span 0.132 in Check Bending Stress (True Dimensions) 5LQGHOV/DNHYLOOH01