Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA207207-17902 Hidden Creek Tr Permit Pack
CANNOT HOOK TO CITY SEWER/WATER RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: FIRST FLOORTOTAL3,094 SF--GARAGEBASEMENTFLOOR AREAFINISHED-648 SFUNFINISHED200 AMP SERVICEGARAGE RIGHTSECOND FLOOR1,204 SF-SIDEWALK58 SFGARAGE SLABBASEMENT SLABFLATWORK SQUARE FOOTAGE941 SF614 SF2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"DE862 SFBASEMENTHIGHVIEW RIDGELOT 9, BLOCK 317902 HIDDEN CREEK TRAILINVENTORY HOMELAKEVILLE, MN 55044ELEVATION BNOTED OTHERWISE ON PLANS.ALL HEADERS ARE (2) 2x10 TYPICAL UNLESSWITH DIMENSIONS TO BE VERIFED SHALLTRUSS DESIGN BY MFG. TRUSSES NOTEDHEADERS:TRUSSES:BE FIELD MEASURED BY TRUSS SUPPLIER6'-11-3/8"1,028 SF166 SF6'-5-1/2"2018 BUILDING CODE2015 ENERGY CODE2'-018"4'-038"14'-438"4'-038"1'-434"1'-434"3'-6"2'-014"9'-118"3'-214"SHEETROCK6'-312"2'-018"LINE OFLINE OFFIREPLACESHEETROCK4'-51 8"4'-8" 4'-8"2'-014"FIREPLACE / ENTERTAINMENT CENTERSCALE: 1/4" = 1'-0"TILE1'-5"6"2'-614"2'-178"GreatRoom4'-818"GAS FIREPLACE6'-0"B24x24 FIXED24x24" FIXED(2) 2x10(2) 2x1015'-1"2'-3"6'-0"2'-178"4'-478"1'-5"T.O. RIM6x6 POST12" CONC. PIER1x6 LP TRIM1x6 LP TRIM2'-0"T.O. FTG.VARIEST.O. WALL1'-2"SCALE: 3/4" = 1'-0"COLUMN #2 - 14" STRAIGHT1'-4"5/4" CEDAR DECKING2x10 DROPPEDHEADER2x8 DECK JOISTCEDARMILL TEXTURELP PANEL WITH3/8" BEAD VULKEM CAULKINGALL 4 SIDES& BACK OF COLUMN1x3 LP TRIM ON FRONT1x2 ON EACH SIDEALUMINUM SOFFIT1'-8"714"20" WIDE X 7-1/4" TALLSOFFITEL. 107'-0"GaragePorchWOOD666'-6"4'-0"2'-6"2'-0"SIDEWALK 58 SF3'-6"4'-0"12'-0"FRAMERS - MAKE SURE THERE IS ICE & WATER SHIELD BEHIND PORCH FRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETE& DECK LEDGERSYOUNGFIELD SERIESEXTERIOR FOUNDATION INSULATION8'-4" TALL FOUNDATION WALLSSCALE: 1-1/2" = 1'-0"DUCT CHASE AT FLOOR TRUSS1A-11'-8" FLOOR TRUSS 3/4" SUB-FLOOR1-1/2" TOP CHORD8" x 8"DUCT1-1/2" SPRAY FOAM (R-10)1-1/2" BOTTOM CHORDFILL 20" FLOOR TRUSS WITHLOOSE FILL FIBERGLASS INSULATION9" = R-23 6" ROUND PIPE07-28-22A-0COVER SHEETROCKFORD 3 - 4 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode09/27/2022dmathews SCALE: 1/4" = 1'-0"A-11FRONT ELEVATION - B - 4TH BEDROOM OPT.8'-4"9'-118"T.O. SLABELEV.100'-4"T.O. FTG.ELEV.100'8'-118"12812" RAKE END OVERHANG1'-0"4:128'-5"1'-6"1'-6"FOR BRACED WALL REQUIREMENTSBOTH GARAGE PIERSUSE 1/2" OSB SHEATHING6" HARDIE FREEZE BD.6" HARDIE FREEZE BD.WOOD DECKDOWN 7" FROM SUB-FLOORFRAME WOOD PORCH(6" AFTER DECKING)12" RAKEVINYL SHAKES6" WINDOW TRIMHARDIE COLORPLUSHARDIE SKIRT1ST FLRSUBFLOORELEV.109'-6 18""T.O. MAINFND. WALLELEV.108'-4"WALL PLATEELEV.118'-7 1/4"2ND FLRSUBFLOORELEV.119'-7 7/8"WALL PLATEELEV.127'-9"1ST FLRSUBFLOORELEV.109'-6 18""1'-6"1281'-6"1286:12128VINYL SIDINGVINYL SIDINGSHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVES)GARAGE PLATEPLATE 117'-11-1/8"FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWNON ATTACHED DETAILS.4:128" TRIM BD.8:128'-0"16'-0"8'-0"8'-0"07-28-22ELEVATIONSROCKFORD A-1TWO STORY 4 BEDROOM LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 SCALE: 1/8" = 1'-0"LEFT ELEVATION3A-2A-2RIGHT ELEVATION2SCALE: 1/8" = 1'-0"A-21REAR ELEVATIONSCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"ROOF PLANA-241ST FLOORELEV. 109'-6-1/8"2ND FLRELEV.119'-7 7/8"9'-118"T.O. SLABELEV.100'-4"GAS F.P.VENT8:1230'-0"1'-0"1'-6"WALL PLATEELEV.127'-9"1'-0"8:121'-0"8:12EGRESSWINDOW4:121'-0"1261ST FLOORELEV. 109'-6-1/8"2ND FLRSUBFLOORELEV.119'-7 7/8"9'-11 8"WALL PLATEELEV.118'-7 1/4"1'-0"HARDIESIDINGT.O. SLABELEV.100'-4"1'-6"22'-0"8:1222'-6"1'-0"21'-6"GARAGE WALL PLATE117'-11-1/8"1'-0"1264:12GARAGEWALLPLATE117'-11-1/8"6:121ST FLOOR2ND FLRELEV.119'-7 7/8"T.O. SLABELEV.100'-4"WALL PLATEELEV.127'-9"ELEV. 109'-6-1/8"1281'-0"128ELEV. 109'-6-1/8"1ST FLOOR8 ROOF VENTS1'-0"1'-0"1'-6"8:128:128:126:126:12 8:128:124:12 1'-0"8:128:124:12 18" MIN.1'-0" 1'-0" 1'-0" 5'-0"1'-6"HARDIESIDINGHARDIESIDINGROCKFORD07-28-22ELEVATIONSA-24 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670ELEVATION - B Secure door closed until deck isconstructed with a separate permit. BASEMENT PLANA-31SCALE: 1/4" = 1'-0"FURN.WATERHEATERMechanicalRoom4" CONC. SLAB166 SFFLR.DRN.SUMPBedroom #5CARPETHVAC SOFFIT40'-0"11-7/8" TJI JOISTS @ 16" O.C.T.O. 6" CURBEL. 108'-4"T.O. FOOTINGELEV. 100'-0"T.O. 6" CURBEL. 108'-4"Unexcavated4" CONC. SLABFamily RoomCARPET30'-0"18'-0"6'-0" 44'-0" 22'-6" 8" 21'-6" 15'-1" 8'-83 4" 22'-0" SLOPE SLAB FOR DRAINAGEVARIES T.O. SLABT.O. 8" WALLEL. 107'-8"T.O. 6" CURBEL. 108'-4"EL. 108'-4"EL. 108'-4"T.O. 6" CURBEL. 108'-4"T.O. 8" WALLEL. 104'-4"T.O. FTG.EL. 107'-8"T.O. 6" CURBT.O. 6" CURB2'-0"1'-412"16'-3" M.O.1'-412"1'-412"8'-3" M.O.1'-412"T.O. 2" LEDGEEL. 107'-8"EL. 104'-4"T.O. FTG.19'-0"11'-0"4" DRAINTILE ATFOOTINGS ON EACHWALL AS MARKED6'-0"48'-0"30'-0"(2) 2x101'-0"5'-0"FIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTEDEL. 100'-0"T.O. FTG.EL. 108'-4"T.O. 8" WALL8'-0" (3) 2x10 2'-6" 60x42 SLIDER D4'-0"66-1/2" M.O.2" BRICK LEDGEEL. 107'-8"36"x36"x12" FTG. PADHOSEBIBHOSEBIB2x8 PORCH LEDGERF TG S . T YP . 2 4 " x 2 4 "LINE OF PORCH ABOVE7'-0"10'-0"2'-0"2'-0"1'-0"5'-0"(2) 2x108'-0"UP 15R28"Stairs4'-3"BEAM POCKET6'-612"4'-6"HALF WALL17'-2" 6'-214" 32"4' BI-FOLD4'-7"11'-712"8'-214"13'-934"6" CURB ON TOP OFFOOTINGS AT INTERIORBEARING WALLS (TYPICAL)TOP OF CURB FLUSH WITHTOP OF BASEMENT SLAB10'-234"11'-934"6'-4" 8'-4" TALL FOUNDATION WALLT.O. SLABEL. 100'-4"8" x 20" - TYPICALCONCRETE FOOTINGS5,000 LB. FOOTINGSTRENGTH MIX12" CONC. PIERSSHOULD BE THEPORCH FOOTINGSSAME HEIGHT AS THEHOUSE FOOTINGSIF SOIL IS UNDISTURBEDMAKE FOOTINGS 42" DEEP11-7/8" LSL JOISTS @ 16" O.C.CDS8" x 20" - TYPICALCONCRETE FOOTINGS5,000 LB. FOOTINGSTRENGTH MIX1A-61A-78'-21 4" 2'-0" VOID ALLOW FOR SEWER24" VOID TOBathVINYL40 SF (FLR)28"30"48x34 11'-834"(2) 9-1/2" LSL 3x5 PSLDROPPED11'-834"ELEVATION B ADD36"x36"x12" FTG. PAD14'-11"6" WIDE x 12-1/2" TALL(3) 1-3/4" x11-7/8" LVL - DROPPED36"x36"x12" FTG. PAD8'-0"ADD FOOTING W/ELEVATION B(1) 1-3/4" x11-7/8" LVL (1) 1-3/4" x11-7/8" LVL11-7/8" TJI JOISTS @ 16" O.C.BEDROOMSTAIRREC ROOMBATHMECHANICALTOTAL178 SF86 SF524 SF79 SF161 SF1,028 SFROOM SIZESMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"DE6'-11-3/8"6'-5-1/2"BASEMENT PLANA-307-28-22TWO STORY ROCKFORD LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. SCALE: 1/4" = 1'-0" FIRST FLOOR PLAN A-4 1 ELEVATION B2'-614"2'-178"(2) 36"x66" MULLED Garage@ 19.2" O.C.20" FLR TRUSSUPPER LEVEL WALL LINE @ ELEV. C Great Room CARPET Foyer WOOD 20 MINUTE FIRE RATED DOOR RO0F TRUSSES @ 24" O.C.MONO TRUSSES@ 24" O.C.30'-0" 8'x8' O.H. DOOR6'-0"9'-0"5'-11"30'-0"8'-7"22'-0"4'-3"22'-6"6'-0"9'-91 2" 18'-0" 8'-0" 1'-6"16'-0" 19'-0" 1'-6" (2) 1-3/4"x11-7/8" LSL - CONT. 16'x8' O.H. DOOR 1'-6"1'-6"8'-0" 11'-0"44'-0"2'-0"ROOF GIRDER4'-818"GAS FIREPLACE6'-0"(2) 2x10 B A24x24 FIXED24x24" FIXED(2) 2x10RAILING TO LANDING 48'-0"6'-0"6'-0"6'-0" 6 6 Porch WOOD 7'-0"10'-0" 1'-0"5'-0"6'-0"5'-0"3'-6" (2) 1-3/4"x7-1/4" LSL 66 (2) 1-3/4"x7-1/4" LSL 32"Stairs 5'-93 4"3'-214"2'-0"2'-0" 12'-0"14'-0"(2) 2x10(2) 2x10 (4) 2x6(2) 20" LVL'S 11'-9"15'-1"BOTTOM OF GARAGE DOOR SHOULD BE SET 4" DOWN FROM TOP OF POURED WALL START SLAB AT TOP OF WALL AT BACK OFOF WALL AT BACK OF GARAGE PORTAL FRAME4'-838"36"32"(3) 2x6PANELACCESSATTIC22x30LINE OF 2ND FLR.8'-0"8'-0"Study CARPET 24" 11'-934"SEE FRAMING PLAN11-7/8" TJI JOISTS SEE FRAMING PLAN11-7/8" TJI JOISTS6'-0"18'-0"8'-214"24"Pantry WOOD BENCH5'-0" BI-FOLDMud Room VINYL 36" DRYWALLOPENING (+96") 28"REF.GASRANGEBath WOOD 37 SF (FLR)5'-0"24"7'-21 4" 24"17'-8"(2) 1-3/4x 11-7/8" LSL - FLUSH ROD & SHELF 2'-7"3'-4"ROD & SHELF2'-6" 6'-81 4" 40'-0" D.W.3'-9"4'-2"2'-0"69"x 24"ISLAND TOP SIZE 72x42 5'-9"3'-6"(2) 4" LEGS 7'-0"4'-012"1'-412"6'-0" X 8'-0" PATIO 12'-3"12'-2"3'-314 "Dining Room WOOD 4'-8"12'-4"2'-3"6'-0"2'-178"11'-8" 2'-6" 4'-61 2" 4'-9"8'-214"4'-358"4'-2"6'-0"10'-134" 15'-0"(2) 2x104'-3"1'-8"B 20'-0"36x48 SH C 54x66 FIXED (2) 2x10 30x6630x66 2-2x62-2x6B Kitchen WOOD (2) 11-7/8" LSL - FLUSH(1) 11-7/8 LSL - FLUSH O.C. (LANDING) 2x8 @ 16" DN UP 1/2" SHEATHING - EXT. TYPICAL GARAGE WALL 2x4 & 2x6 STUD WALLS @ 16" O.C. W/ 2x6 STUD WALLS @ 16" O.C. W/ (R=21) FIBERGLASS BATT INSULATION 4 MIL POLY VAPOR BARRIER & 1/2" GYP. BD. TYPICAL EXT. WALL INSIDE AND 1/2" SHEATHING - EXT. 2x6 WALL 18'-31 2" S 14'-11"24x24" FIXEDWINDOW SILLS MORE THAN 6" ABOVE FINISHED GRADE (SURFACE BELOW) OR LESS THAN 24" FROM FINISHED FLOOR SHALL REQUIRE A WINDOW OPENING CONTROL DEVICE. DROP GARAGE 8-1/8" FOR 2ND FLOOR OVER GARAGE (2) 2x10 1'-0"(1) 1-3/4" x 11-7/8" LSL(1) 1-1/2" x 11-7/8" LSL(2) 2x10 (2) 2x10 (2) 9-1/2" LSL (2) 2x6(3) 2x67'-1114"(2) 2X12 (3) 2x6(2) 2x6(2) 2x62x4 INTERIOR WALLS 2x6 INTERIOR WALLS SHEATHING - INSULATED CONCRETE WALLS BRICK / BRICK LEDGE 2x6 EXTERIOR WALL WITH 1/2" FUTURE FINISH WALL LEGEND FINISHED ROOM SIZES STUDY - CARPET GREAT ROOM - CARPET 76 SF 197 SF STAIRS - CARPET 78 SF KITCHEN/DINE/FOYER - WOOD 426 SF MUD ROOM & W.I.C. - VINYL 81 SF POWDER BATH - WOOD 31 SF ELEVATION - A MIN. TREAD 10" STAIR REQUIREMENTS MAX. RISE 7-3/4" 10"734"MIN. NOSING 3/4" MAX. NOSING 1-1/4" 1-1/4" HEADER HEIGHT SCHEDULE A B C 6'-11-1/4" 8'-0" 7'-6" D E 6'-5-1/2" 6'-11-3/8"ROCKFORD07-28-22 FIRST FLOOR PLAN A-44 BEDROOMTWO STORYLAKEVILLE, MN 5504422260 DODD BLVD.Phone (952) 469-4066YOUNGFIELD HOMESCOUNTRY JOE HOMESLIC. # BC6276705 5 5 5 5 5 5 PFH PFH 5 5 5 BWPs Above DN 16RRO0F TRUSSES@ 24" O.C.30'-0"5'-0"11'-112"5'-41 2" 31'-0"11'-734"22'-0" 22'-6" 8'-11 4"11'-734"18'-0"8'-0"SCALE: 1/4" = 1'-0"FIRST FLOOR PLAN - ELEV. BA-5119'-0"11'-0"44'-0"WINDOW SILLS MORE THAN 6" ABOVEFINISHED GRADE (SURFACE BELOW) ORLESS THAN 24" FROM FINISHED FLOORSHALL REQUIRE A WINDOW OPENINGCONTROL DEVICE.48'-0"6'-0" 5'-0"6'-0"5'-0"Stairs6'-0"3'-0"12'-0"14'-0" 11'-11"START SLAB AT TOPOF WALL AT BACK OFOF WALL AT BACK OFGARAGE8'-2"6'-0" 8'-0"11'-734"1A-718'-0"7'-91 2"4'-6"7'-134"6'-812"40'-0"4'-334"14'-312"7'-8"42"HIGH WALLW/ WOOD CAPS(2) 9-1/2" LSL60x3230"30"30"28"WD11'-734"32"4' BI-FOLD4' BI-FOLDROD & SHELFW.I.C.Carpet3'-1134"30"2'-0"SAME HEIGHT AS PLATE (8'-1-1/8")(+8") STEP UP CEILING8'-9-1/8")2'-7"28"28"(2) 36X60 MULLED(2) 2x10A6'-0"6'-0"(2) 36X60 MULLED(2) 2x10AROD & SHELF24x2412'-0"3'-0"6'-0"36x60(2) 2x10A30X48A2'-114"Bedroom #2CARPETBedroom #3CARPET1A-66'-6"Bedroom #4CARPETSSSSCDPrimaryBedroomCARPETBathVINYL35 SF (FLR)LaundryVINYL57 SF (FLR)13'-1034"6'-5"HallCARPET(2) 2x105'-612"6'-114"6'-5"(2) 2x102'-0" 22'-0" 8'-11 4"6'-9"3'-41 4"30x48(2) 2X10A2'-0"ROD & SHELF28"W.I.C.Carpet28"PrimaryBathVINYL65 SF (FLR)60x3476" VANITY5'-312"2'-414"7'-734"6'-414"5'-312"ROD & SHELF36x60A1'-1134"2'-034"4"10'-3"4"36x60A1'-103 4"1'-103 4"EFRAME WALL (+42")W/ QUARTZ CAP2'-0"ROOF GIRDER (2) 9-1/2" LSL(3) 2x6PANELACCESSATTIC22x309'-111 4"60" VANITY(2) 2x102x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"HEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6-11-3/8"E6-5-1/2"ELEVATION B - STANDARDFINISHED ROOM SIZESPRIMARY BEDROOM - CARPETLAUNDRY - VINYLPRIMARY BATH - VINYL185 SF57 SF93 SFHALLWAY - CARPET98 SFBEDROOM # 2 - CARPET142 SFBEDROOM # 3 - CARPET152 SFBATH - VINYL56 SFPRIMARY W.I.C. - CARPET83 SFTHE TOTALS FOR FLOORING ARE ON FLOOR PLANBEDROOM # 4 - CARPET151 SFROCKFORD07-28-22SECOND FLOORA-54 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670Temper6333-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). SCALE: 1/4" = 1'-0"BUILDING SECTION - ELEV. BA-618" x 20" CONC. FTG'S4" CONCRETE SLABTYPICAL11-7/8" LSL JOISTS @ 16" O.C.8'-4" 7'-8"T.O. 6" CURBELEV. 108'-4"BOTTOM OF ALL FOOTINGS TO BE 42" MINIMUMBELOW FINISH GRADE RESTING ON UNDISTURBED SOIL1288'-5"1'-6"9'-218"10'-134" 8'-11 8"TYPICAL STAIR CONSTRUCTION NOTES:* 6'-10" MINIMUM HEADROOM* (3) 11-7/8" STAIR STRINGERS W/* 11" TREADS* PROVIDE 36" HIGH HANDRAILS & GUARD RAILS PER CODE.~ MINIMUM TREAD DEPTH 10" - MAX RISE 7-3/4"MINIMUM NOSING 34" MAX. NOSING 1-1/4"20" FLOOR TRUSSESHVAC SOFFITBEYONDBEDROOM #4BEDROOM #2FoyerGarage4" CONCRETE SLAB PITCHEDTOWARDS OVERHEAD DOORS5/8" TYPE X GYP. BRD.ON ALL COMMON WALLS &CEILINGS.MUD ALL JOINTS1/2" SHEATHING - EXT.TYPICAL GARAGE WALL2x6 STUD WALLS @ 16" O.C. W/R-49 ROOF INSULATIONTRUSSES @ 24" O.C.PRE-ENGINEERED ROOFR-49 ROOF INSULATIONTRUSSES @ 24" O.C.PRE-ENGINEERED ROOFBASEMENT11-7/8" TJI JOISTS @ 16" O.C.9'-11 8"DROP GARAGE WALL 8-1/8"81 8"5,000 LB. FOOTINGSTRENGTH MIX8'-4" 1'-15 8" HEEL HALLStudy1'-0"1286:121281'-218"1'-058"1ST FLRSUBFLOORELEV.109'-6 18""2ND FLRSUBFLOORELEV.119'-7 7/8"WALL PLATEELEV.127'-9"T.O. MAINFND. WALLELEV.108'-4"WALL PLATEELEV.118'-7 1/4"SHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVESMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"73 4"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"ROCKFORD07-28-22SECTIONA-64 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 BUILDING SECTION2A-7SCALE: 3/8" = 1'-0"8'-118"4" CONCRETE SLAB8" x 20" CONC. FTG'SPLATE W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILL8'-512"ELEV. 100'-0"TOP OF FOOTINGELEV. 118'-7-1/4"ELEV. 119'-7-7/8"TOP OF PLATE2ND FLOORTOP OF 8" CONC.ELEV. 108'-4"ELEV. 109'-6-1/8"1ST FLOOR9'-118"1178" 34" 34" 117 8"ELEV. 127'-9"2ND FLOOR CLG.BOISE RIM BOARD1-1/8" OSB RIM BOARDWATERPROOFING1) COAT EXTERIOR W/ POLYUREA WATER-2x6 STUD WALLS @16" O.C. W/ (R=21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE BOISE RIM BOARD1-1/8" OSB RIM BOARD2x6 STUD WALLS @16" O.C. W/ (R=21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE 11-7/8" TJI JOISTS @ 16" O.C.BLOCKING AT FOUNDATIONWALLS PARALLEL TO FRAMINGSEE DETAIL 3/A-7PROOFINGDUCTSPACEBLOCKBLOCKOR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.R-49 ROOF INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.OR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.MIN. 6" ENERGY HEALSEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTIONR-20 SPRAY FOAM @ RIMR-20 SPRAY FOAM @ RIM(R-20)(R-20)5,000 LB. FOOTINGSTRENGTH MIX2) FOAM W/ POLYURETHANE (R-15)6 MIL POLY SLIP SHEET OVERFOAM PRIOR TO BACKFILLAS REQUIRED PER CITY8'-4" CONCRETE WALLS3/4" OSB FLOOR SHEATHINGGLUED AND NAILED3/4" OSB FLOOR SHEATHINGGLUED AND NAILEDMAINTAIN A MIN. CL.OF 6" FROM GRADETO BOTTOM OF SIDINGRIGID METAL FLASHING INSTALLED BY SIDERPROTECTION TO6" BELOW GRADE1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)1/2" EXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISE1/2" EXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISESHINGLES OVER 15#15/32" OSB ROOF SHEATHINGBUILDING PAPER(ICE DAM EAVES8'-4" WALLS - (1) 2x6 TOP PLATE FIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARD WITH80 SQUARE FEET UNPROTECTED3" EXTERIOR FOAM INSULATION ATLOOKOUT/WALKOUT SIDE WALLS. 2"FOAM AT FULL BASEMENT & 4' FROSTFOOTINGS.11-7/8" LSL JOISTS(UNFINISHED BASEMENT)3) APPLY ABOVE GRADEFOUNDATION COATINGROCKFORD07-28-22SECTIONA-7TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 &GUETKRVKQP&CVG4GXKUKQP2TQLGEV0WODGT&CVG55JGGVUQH2TKPV0COG5KIPGF.KEGPUG0WODGT0KEM*CPUQP&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC;QWPIHKGNF*QOGU+PE&QFF$QWNGXCTF.CMGXKNNG/0-KNOGT.CPG05WKVG2N[OQWVJ/06GNÄÄYYYJCPUQPITQWROPEQO2.#055*190.+)*6+0$#%-)4170'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)41725&'5+)0%12;4+)*6*#0510)4172..%,WPGÄÄ4QEMHQTF/QFGN'NGXCVKQPU# $)CTCIG4KIJV/KPPGUQVC%QPUVTWEVKQP2#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#05'%6+105#6$4#%'&9#..2#0'.5#$18'%#06+.'8'4'&(.114(4#/+0)6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'/#+09+0&(14%'4'5+56+0)5;56'/(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)41725&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;176411(64755'5$4#%'&9#..2#0'.(.#6Z"1% /+0 2'4$4#%'&9#..2#0'.5+/2510#(4#/+0)#0).''#%*'0& Z0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'. Z0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'. Z0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565$4#%'&9#..2#0'. Z0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0 2'4$4#%'&9#..2#0'.(.#6Z"1% /+0 2'4$4#%'&9#..2#0'.(.#6Z"1% /+0 2'4$4#%'&9#..2#0'.$4#%'&9#..2#0'. Z0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0 2'4$4#%'&9#..2#0'.$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10 411(64755'5 (.114,1+565 (.11464755'5&'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19 144'2.#%'Y#&'37#6'&'26*Z/'/$'4Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.;Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.;':6'4+14$'#4+0)9#..4'24'5'065(+)74'4 +0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'=%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'7*190+06*'&'6#+.5*''65 /+0.'0)6*+0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14�%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19 /+0.'0)6*Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5411(64755'5(#56'0'&612.#6'5Y Z61'0#+.5 5+/2510*%.+20#+.$1661/2.#6'614+/,1+56$.1%-+0)Y F0#+.5'8'4;0#+.$1661/2.#6'614+$$10$4#%'64755Y F0#+.5'8'4;0#+.'#%*,1+56616122.#6'5Y Z0#+.5Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y Z0#+.5'#%*0#+.'#%*64755616122.#6'5Y Z61'0#+.5411(64755(#56'0'&612.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y F0#+.5'8'4;0#+.4+/6122.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'61.#&&'464755Y F0#+.5'8'4;0#+..#&&'464755616122.#6'5YZ0#+.5"1%+06'4+149#..2'42'0&+%7.#461(4#/+0)+06'4+149#..2#4#..'.Y(4#/+0)Z$.1%-+0)$'69''0411(64755'50#+.'&616122.#6'5Y Z0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y Z0#+.5'#%*0#+.'#%*,1+56616122.#6'Y Z0#+.50#+.$1661/2.#6'61$.1%-+0)Y F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y Z0#+.5'#%*0#+.'#%*64755616122.#6'Y Z61'0#+.52418+&'411(64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'61$.1%-+0)Y F0#+.5'8'4;2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'61$.1%-+0)Y F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YZ61'0#+.5"1%/#6'4+#.59#..567&5 14.'5552(567&)4#&'14$'66'49#..567&5 18'452(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*7.6+/#6'':2$%1&'/+00'516#4'5+&'06+#.%1&'5%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14�%'9+6*6*+5&1%7/'0656#0&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952#0&%5Ä952#ZZ567&552#%'&$;5722.+'401661':%''&1%$':6'4+145*'#6*+0)/+05647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)#..+06'4+149#..5#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+#701#Z14Z567&552#%'&"1%$9#..5*'#6*+0)/+0);257/5*'#6*+0)(#56'0'&61(4#/+0)YF%11.'40#+.5"1%/#:146;2'599#..$1#4&5%4'95"1%/#: /+0+/7/567&2'0'64#6+10#..(.1145#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+##(.114(4#/+0)52#%'#/#:+/7/1(1%$(.1145*'#6*+0)5647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'57221465#..411(5#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+##411((4#/+0)52#%'#/#:+/7/1(1%$(#56'0#..411((4#/+0)616122.#6'59+6*5+/2510*%.+214'37+8#.'06#0& Z61'0#+.5%411(5*'#6*+0)5647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)#.10).'0)6*1(9#..5.#29#..6122.#6'5#/+0+/7/1(#0&(#56'061)'6*'49+6* Z+0.#2<10'#6%140'45#0&+06'45'%6+105.#22.#6'5#0&2418+&' Z(#%'0#+.5%100'%6+10501652'%+(+%#..;016''61$'+0#%%14�%'9+6*%1&'6#$.'4 6*''064;214%*+5%105+&'4'&61$'#24+/#4+.;12'0010Ä'55'06+#.2146+101(6*'5647%674'#0&+5':%.7&'&(41/6*'18'4#../#+09+0&(14%'5;56'/1(6*'*1/'2418+&'%1&'4'37+4'&72.+(6%100'%6+105#6#..21565#0&6'05+10%100'%6+105#6.'&)'45$4#%'&9#..2#0'.(#56'0$1661/2.#6'61,1+56$.1%-+0)Y F0#+.5'8'4;1%%#06+.'8'4'&(.114,1+56$;5722.+'4(4#/'9#..$4#%'&9#..2#0'.$'.19$.1%-+0)$'69''0,1+565#5(1..195x(.#6Z612 $1661/14,1+56/#6'4+#.145#90$.1%-+0)x2.;911&5*''60#+.'&61ZUY F0#+.5612 $1661/x%+4%7.#4*1.'7261/#;$'%76+061%'06'41(2.;911&0#+.(.1145*'#6*+0)61$.1%-+0)YF0#+.5"1%(#56'0$1661/ZY F0#+.5'8'4;1%2156Ä+056#..'&*1.&190126+105(4#/+0)&'6#+.5(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.ÄÄ/#:*'+)*6 (#56'06122.#6'61*'#&'4Y 4195F5+0-'40#+.5"1% ZZ$'#4+0)567& ZZ(7..*'+)*6567&'#%*'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0Ä(41/%'06'41(*'#&'4*'+)*6#54'3& Z51.+&$.1%-+0)4'37+4'A*'#6*+0),1+06 ZZ$'#4+0)567&5/+0 8'4+(;Y5722.+'42418+&'ZZ+0(+..9#..#$18'*'#&'4#54'3&5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190 4'('4615(14#.6'40#6+8'126+105(170+109#..$'.19.'0)6*1(%106+07175*'#&'4#0%*14$1.6 /+0'/$'&YZZ2.#6'9#5*'40#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5 0#+.5*'#6*+0)#4170&2'4+/'6'4Y 4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1%5+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55(#56'0-+0)567&61*'#&'4Y 4195F5+0-'40#+.5"1%.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&0#+.+0)2418+&'(#56'0+0)1(#$18'(4#/+0)'37#.616*#6&'6#+.'&(14$4#%'&9#..2#0'.5%106+07175.5..8.*'#&'46157221468'46+%#..1#&5$;5722.+'4 /+09+&6* /+0&'26*4'3&ÄÄ%10%4'6'(170+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*190YZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*146*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;619#.-176(170+1056*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;61.11-176(170+105722'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0$#6*411/126+10'.'8#6+10$/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6$4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6$4#%'& 9#...+0'%105647%62146#.(4#/'#55*190+05 Ä(6 Ä(6 Ä(6$4#%'&9#...+0' Ä(6 $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6$4#%'&9#...+0' Ä(6 Ä(6$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6$4#%'&9#...+0' Ä(6$4#%'& 9#...+0' Ä(6 $4#%'& 9#...+0' Ä(6 Ä(6 Ä(6 Products PlotID Length Product Plies Net Qty 1-11.875" LVL-22' 22' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 1 1 3-11.875" LVL-12' 12' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 3 3 3x5 PSL 10' 0" 3 1/2" x 5 1/4" 1.8E Parallam PSL 1 1 TS1 30' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 13 TS2 22' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 8 TS3 14' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 8 1-11.875" LSL-10' 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 2-9.5" LSL-8' 8' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 Rim 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 9 2-2x10 Trtd. 12' 0" 2 X 10 SP No.1 P 2 2 2-2x10 Trtd. 8' 0" 2 X 10 SP No.1 P 2 2 Start Joist Layout Here. 16" o/c Framing Connector Summary PlotID Qty Manuf Product Face Nails Top Nails Member Nails Web Stiff H1 1 Simpson HU9 18- 10dx1.5 - 6- 10dx1.5 No H2 4 Simpson LUS210 8- 10dx1.5 - 4- 10d No Wall Framing PlotID Length Product Plies Net Qty BBOHd1-3 6' 0" 2 x 10 SPF No.1/No.2 3 3 CS CS CS CSCS 3-11.875" LVL-12' 2-9.5" LSL-8' 1-11.875" LSL-10' 3x5 PSL 2-2x10 Trtd. 2-2x10 Trtd.RimRimRimRim RimRim Rim 1-11.875" LVL-22'Solid Blocking Rim Round holes larger than 3-5/8" up to 7-1/4" max. in 1.5" x 11-7/8" 1.5E TimberStrand LSL joist only Edge of large holes need to be at least 4 times the diameter of the largest hole (for a 7-1/4" hole, the closest distance allowed to the next hole is 29", even if the next hole is a small 12" diameter hole). The hole must be centered within the joist vertically. No square or rectangular holes No more than (2) holes between 3-5/8" and 7-1/4" diameter allowed per span. See chart below for minimum distance from inside face of bearing to edge of hole for holes larger than 3-5/8" but not greater than 7.25" Minimum distance from edge of hole to inside face of bearing (end or intermediate) 4"5" *6.5" * 7.25" * 2'-0"2'-0" 3'-0"3'-6" * Allowable spans shown in TB-711 must be reduced by 9" with these size holesBBOHd1-3H1 TS1 16" O.C. TS3 16" O.C. TS2 16" O.C. H2 4-2x6 Customer:Job Name:Address/Lot:Youngfield HomesInventory Home17092 Hidden Creek TrailCity, State:Lakeville, MNPlan/Model #:Rockford BJob Number:25695Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 1 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:8/17/22Revised By:Revision Date:Revision #:SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Framing Connector Summary PlotID Qty Manuf Product Face Nails Top Nails Member Nails Web Stiff H1 1 Simpson HU9 18- 10dx1.5 - 6- 10dx1.5 No H2 2 User HUCQ1.81/11-SDS Not Required H5 21 Simpson IUS2.06/11.88 10- 10dx1.5 - 2- Strong-Grip No Products PlotID Length Product Plies Net Qty F32' 32' 0" 11 7/8" TJI 210 joist 1 8 F22' 22' 0" 11 7/8" TJI 210 joist 1 5 F18' 18' 0" 11 7/8" TJI 210 joist 1 5 F14' 14' 0" 11 7/8" TJI 210 joist 1 16 F8' 8' 0" 11 7/8" TJI 210 joist 1 3 2-20" LVL-16' 16' 0" 1 3/4" x 20" 2.0E Microllam LVL 2 2 2-11.875" LSL-20' 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 1-11.875" LSL-18' 18' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 1-11.875" LSL-10' 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 2-11.875" LSL-8' 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 TS1 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 2-11.875" LSL-6' 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 TS2 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 2-7.25" LSL-20' 20' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 2 2 Rim 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 9 2x8 Flat Blocking 10' 3 1/2" 2x8 blocking (11 7/8" joist depth) 1 1 2-2x12-12' 12' 0" 2 x 12 SPF No.1/No.2 2 2 Wall Framing PlotID Length Product Plies Net Qty TSHd1-2 4' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 BBOHd1-2 12' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd2-2 8' 0" 2 x 10 SPF No.1/No.2 2 4 BBOHd3-2 4' 0" 2 x 10 SPF No.1/No.2 2 12 Start Joist Layout Here. 16" o/c CS CS CS 2-11.875" LSL-8'RimRimRimRimRim Rim Rim 2x8 Flat Blocking 1-11.875" LSL-10'TS21-11.875" LSL-18'TS1BBOHd1-2 BBOHd3-2BBOHd3-2BBOHd3-2BBOHd2-2 BBOHd3-2 BBOHd2-2 BBOHd3-2 2-11.875" LSL-6' 2-11.875" LSL-20' E1 Alt 2' TJI® JOIST 2" 2x6 (min.) solid sawn or 4 12" wide Timberstrand® LSL rim board, full length in bay and tight to each joist flange. Connect to plate with 8d (0.113" x 2 38") nails at 6" on-center. 2416 span rated sheathing (716" Min.). Attach with 8d (0.113" x 2 38") nails at 6" on-center along panel edges and in field. Use pressure treated plywood for ground level cantilevers.E1 ALT Timberstrand ® LSL rim board to match TJI® depth WARNING Joists are unstable until braced laterally, Safety bracing required during installation. Lateral load transfer for this detail is 180 PLF (pounds per lineal foot). Additional connections may be required to transfer lateral loads from wall above. 2-7.25" LSL-20' TSHd1-2 2-20" LVL-16'Rim Girder Truss BBOHd3-2 2-2x12-12'H2H1 H21' 1"1' 7" F14' 16" O.C. F14' 16" O.C. F14' 16" O.C. F32' 16" O.C. F18' 16" O.C. F8' 16" O.C. F22' 16" O.C.H5 H5 H5 H5 H5 2 Trimmers 2 Trimmers 4-2x6 2-2x6 2-2x6 3-2x6 ← Floor Trusses →3-2x6 9893# 3-2x6 Customer:Job Name:Address/Lot:Youngfield HomesInventory Home17092 Hidden Creek TrailCity, State:Lakeville, MNPlan/Model #:Rockford BJob Number:25695Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 2 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:8/17/22Revised By:Revision Date:Revision #:SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Wall Framing PlotID Length Product Plies Net Qty TSHd1-2 4' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 BBOHd1-2 8' 0" 2 x 10 SPF No.1/No.2 2 4 BBOHd2-2 4' 0" 2 x 10 SPF No.1/No.2 2 10 BBOHd1-2 BBOHd2-2 BBOHd2-2 BBOHd2-2 TSHd1-2 BBOHd1-2 Girder TrussBBOHd2-2 BBOHd2-22 Trimmers 3-2x6 Customer:Job Name:Address/Lot:Youngfield HomesInventory Home17092 Hidden Creek TrailCity, State:Lakeville, MNPlan/Model #:Rockford BJob Number:25695Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 3 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:8/17/22Revised By:Revision Date:Revision #:SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. License Number:1-1-21 46665Date: SCOPE OF DRAWINGS: THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2021. 2021 FOUNDATION GUIDE: DRAWING INDEX: SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE DETAIL S15 COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 150 1.001 January 1, 2021 S0 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS SCOPE, INDEX, & CERTIFICATION Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 DRAWING USE GUIDELINES AND LIMITATIONS THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. LIMITATIONS 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST OR STRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED. 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. COLD WEATHER GUIDELINES: 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. MATERIALS CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM EQUIVALENT REBAR TABLE FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 151 1.001 January 1, 2021 S1 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS DRAWING LIMITATIONS & MATERIALS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GENERAL NOTES 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED IN ACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 152 1.001 January 1, 2021 S2 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS GENERAL NOTES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MINDETAIL B 3" MIN TYPCONCRETE STRIP FOOTING 11B DETAIL A 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLYELEVATION STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 153 1.001 January 1, 2021 S3 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEP FOOTING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHOR BOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 154 1.001 January 1, 2021 S4 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WALKOUT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 155 1.001 January 1, 2021 S5 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS LOOKOUT/KNEE WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4x4'-0" HOOKS @ 24" O.C. BENT OR DRILLED AND EPOXY GROUTED 3'-0"1'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 156 1.001 January 1, 2021 S6 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS UNBALANCED FOUNDATION DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING PER CODE OR BY BUILDING DESIGNER, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN BELOW 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE CLEAR HEIGHT OF 8'-0" OR LESS (2)#4xCONT. HORIZONTAL BARS CLEAR HEIGHT OF 8'-0" OR MORE (3)#4xCONT. HORIZONTAL BARS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) GENERAL STRIP FOOTING SIZE GUIDE SOIL ONE-STORY STRUCTURE TWO-STORY STRUCTURE 2000 PSF 16" WIDE x 8" THICK 20" WIDE x 8" THICK 1500 PSF 20" WIDE x 8" THICK 26" WIDE x 8" THICK THIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ON MAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHER CONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10", AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS, HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 157 1.001 January 1, 2021 S7 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BASEMENT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 158 1.001 January 1, 2021 S8 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS VERTICAL REINFORCING TABLE Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112" CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 159 1.001 January 1, 2021 S9 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BRICK LEDGE DETAILS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICK x 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS**** BACKFILL TYPECLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 8'-0" 9'-0" 10'-0" 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ** OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1510 1.001 January 1, 2021 S10 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS FLOOR BEARING CONNECTIONS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS* ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPE CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS** ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPECLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1511 1.001 January 1, 2021 S11 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS ANCHOR SPACING TABLES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1512 1.001 January 1, 2021 S12 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON BEARING JOIST BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1513 1.001 January 1, 2021 S13 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON-BEARING TRUSS BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 10'-0" MAX3'-8" MAX2'-6" MIN OPENING1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1514 1.001 January 1, 2021 S14 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WINDOW WELL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRAD E L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1515 1.001 January 1, 2021 S15 Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEPPING DOWN WALL WITH GRADE &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 Site address Date 8/19/2022 Contractor Silver Tree Plumbing & Heating, LLC By Jake Ryan Section A Square feet (Conditioned area inc. 3260 TOTAL VENTILATION 156 basement – finished or unfinished)CONTINUOUS VENTILATION 78 Number of bedrooms 5 # of BEDROOMS 1 2 3 4 5 6 Total/ Total/ Total/ Total/ Total/ Total/ continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/;83 180/90 195/98 210/105 225/113 Equation R403.5.2 2015 Mn Energy Code (0.02 x conditioned space) + (15 X (# of bedrooms + 1))= TOTAL VENTILATION RATE Sq Ft 3260 0.02 65.2 Bedrooms 5 15 75 Plus 1 bedroom 15 TOTAL VENT 155.20 CFM Section B Low cfm: High cfm: 88 158 Section D Control Set at 50%88 CFM HIGH set at 90%158 CFM (BALANCED) Table R403.5.2 2015 Minnesota Energy Code Total and Continuous Ventilation Rates (in cfm) Conditioned space (in sq. ft.) 2015 Mechanical & Energy Code – Ventilation, Makeup, and Combustion Air Calculations Ventilation Method 17902 Hidden Creek Trail, Lakeville Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code) ☒Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery Ventilator) – cfm of unit in low must not exceed continuous ventilation rating by more than 100%. Ventilation Controls (Describe operation and control of the continuous ventilation) Page 1 of 6 Page 2 of 6 One or multiple power vent or direct vent appliances or no combustion appliances One or multiple fan- assisted appliances and power vent or direct vent appliances One atmospherically vented gas or oil appliance or one solid fuel appliance Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column A Column B Column C Column D 1.Enter the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 3260 Estimated House Infiltration (cfm): [1a x 1b]489 2. Exhaust Capacity ERV/HRV=0 a) clothes dryer (cfm)135 135 135 135 b) 80% of largest exhaust rating (cfm); (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) 240 c) 80% of next largest exhaust rating (cfm); NA (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm);375 [2a + 2b +2c] 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above)375 b) estimated house infiltration (from above)489 Makeup Air Quantity (cfm); [3a – 3b]-114 (if value is negative, no makeup air is needed) 4. For makeup Air Opening Sizing, refer to Table 501.4.2 Not required, negative number A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1, 2015 Minnesota Mechanical Code PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS (Additional makeup air will be required for combustion appliances, see KAIR method for calculations) Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. Page 3 of 6 Section E Passive (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Powered (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Interlocked with exhaust device (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Other, describe: Location of duct or system ventilation make-up air: (Determined from make-up air opening table, Table 501.4.2.) NR -114 Makeup Air Opening Table for New and Existing Dwelling Table 501.4.2, 2015 Minnesota Mechanical Code One or multiple power vent, direct vent appliances, or no combustion appliances One or multiple fan- assisted appliances and power vent or direct vent appliances One atmospherically vented gas or oil appliance or one solid fuel appliance Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column A Column B Column C Column D Duct diameter Passive opening 1 – 36 1 – 22 1 – 15 1 – 9 3 Passive opening 37 – 66 23 – 41 16 – 28 10 – 17 4 Passive opening 67 – 109 42 – 66 29 – 46 18 – 28 5 Passive opening 110 - 163 67 – 100 47 – 69 29 – 42 6 Passive opening 164 – 232 101 – 143 70 – 99 43 – 61 7 Passive opening 233 – 317 144 – 195 100 – 135 62 – 83 8 Passive opening w/motorized damper 318 – 419 196 – 258 136 – 179 84 – 110 9 Passive opening w/motorized damper 420 – 539 259 – 332 180 – 230 111 – 142 10 Passive opening w/motorized damper 540 – 679 333 – 419 231 – 290 143 – 179 11 Powered makeup air >679 >419 >290 >179 NA Notes: A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D. Powered makeup air shall be electrically interlocked with the largest exhaust system. Sections F X Size and type FLEX= RIGID= Other, describe: Not required per mechanical code (No atmospheric or power vented appliances) Make-up air for COMBUSTION Passive (see IFGC Appendix E, Worksheet E-1) Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Directions - The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method (KAIR). For new construction, 4b of step 4 is required to be filled out. The example assumes a typical 3,000 square foot home with a finished basement that has a mechanical room that is 10 feet wide by 12 feet long with an 8 foot ceiling. It also assumes installation of a 70,000 btu, 2 pipe condensing furnace; and a 40,000 Btu, power vented water heater. Make-up air for VENTILATION Size and type (round, rectangular, flex or rigid) Page 4 of 6 Furnace/Boiler: Water Heater: INPUT in BTUHS:0 CAS VOLUME:1008 Mech Room Length:18 Mech Room Width:7 Mech Room Height:8 Cubic feet INPUT (BTUH/HOUR)= TRV (ft3)= INPUT (BTUH/HOUR)=0 RVFA (Ft3)=3000 INPUT (BTUH/HOUR)=0 RVNFA (Ft3)=NONE RVFA:3000 RVNFA (Ft3)=0 3000 Ft3 RATIO=1008 DIVIDED BY 3000 EQUALS:0.34 RF = 1 minus Ratio Ratio RF=1 MINUS 0.34 EQUALS:0.66 INPUT (BTUH/HOUR)=0 CAOA=0 divided by 3000 EQUALS:0.00 BTUH/HR per in2 MIN CAOA=0.00 X 0.66 0.00 Square Inches CAOD= 1.13 X Square root Minimum CAOA=0.00 inches Step 1: Complete vented combustion appliance information. __ Draft Hood __ Fan Assisted __-Direct Vent XX FURNACE IS SEALED COMBUSTION (for Furnace, Boiler, and/or Water Heater in the Same Space) IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method Total Btu/hr input of all fan-assisted and power vent appliances Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method __ Draft Hood (Non- fan assist) __ Fan Assisted & Power Vent __ Direct Vent _X_Electric Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) Step 6: Calculate Reduction Factor (RF). (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) Total Btu/hr input of all non-fan-assisted appliances Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) Total Required Volume (TRV) = RVFA + RVNFA 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304 Minimum CAOA = CAOA multiplied by RF Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 Step 8: Calculate Minimum CAOA. If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Page 5 of 6 Input Rating (Btu/hr) 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 IFGC Appendix E, Table E-1 Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance) Standard Method Known Air Infiltration Rate (KAIR) Method (cu ft) Fan Assisted Non-Fan Assisted 1. The 1994 date refers to dwelling constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is .20 air changes per hour (ACH). 2. This section of the table is to be used for dwelling constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published copy. Page 6 of 6 17902 Hidden Creek Trail, Lakeville HVAC Load Calculations for Country Joe Homes 22260 Dodd Blvd Lakeville, MN 55044 Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Friday, August 19, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17902 Hidden Creek Trail, Lakeville Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:17902 Hidden Creek Trail, Lakeville Designed By:Jake Ryan Project Date:8/19/2022 Project Comment: Client Name:Country Joe Homes Client Address:22260 Dodd Blvd Client City:Lakeville, MN 55044 Client Phone:(952) 469-4066 Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces East Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:1,054 CFM Per Square ft.:0.340 Square ft. of Room Area:3,096 Square ft. Per Ton:1,235 Volume (ft³):25,796 Building Loads Total Heating Required Including Ventilation Air:44,432 Btuh 44.432 MBH Total Sensible Gain:23,382 Btuh 78 % Total Latent Gain:6,694 Btuh 22 % Total Cooling Required Including Ventilation Air:30,076 Btuh 2.51 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17902 Hidden ... eat Calc.rh9 Friday, August 19, 2022, 1:02 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17902 Hidden Creek Trail, Lakeville Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.51 1,235 3,096 23,382 6,694 30,076 44,432 523 1,054 523 1,054 1,054 System 1 Main Floor Yes 2.51 1,235 3,096 23,382 6,694 30,076 44,432 523 1,054 523 1,054 1,054 11x16 Ventilation 879 4,287 5,166 5,359 156 156 156 Supply Duct Latent 64 64 Return Duct 4 12 16 24 Humidification 6,182 Zone 1 3,096 22,498 2,331 24,829 32,866 523 1,054 523 1,054 1,054 11x16 1-Basement 1,028 1,133 0 1,133 7,737 123 53 123 53 53 1--4 2-Main Level 1,028 12,238 2,331 14,569 11,670 186 573 186 573 573 5--6 3-Upper Level 1,040 9,128 0 9,128 13,459 214 428 214 428 428 4--6 F:\ ...\17902 Hidden ... eat Calc.rh9 Friday, August 19, 2022, 1:02 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17902 Hidden Creek Trail, Lakeville Eagan, MN 55121 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Anderson 100: Glazing-Anderson 100, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.27, SHGC 0.28 174.8 4,106 0 4,788 4,788 Anderson 100: Glazing-Anderson 100, U-value 0.27, SHGC 0.28 189 4,436 0 5,550 5,550 11G: Door-Wood - Panel, U-value 0.54 20 940 0 292 292 11J: Door-Metal - Fiberglass Core, U-value 0.6 17.8 928 0 288 288 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05, above grade U-value 0.083 1120 4,872 0 0 0 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2108 11,921 0 2,233 2,233 RJ R-20 RIM JOIST: Wall-Frame, Custom, RJ R-20 RIM JOIST R-20 SPRAY FOAM, U-value 0.05 294 1,280 0 302 302 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown insulation in attic, U- value 0.02 1040 1,810 0 1,061 1,061 21A-32: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide, U-value 0.02 1028 1,789 0 0 0 20P-30: Floor-Over open crawl space or garage, Passive, R-30 blanket insulation, any cover, U-value 0.035 180 549 0 70 70 Subtotals for structure:32,631 0 14,584 14,584 People:6 1,200 1,380 2,580 Equipment:1,131 4,262 5,393 Lighting:650 2,217 2,217 Ductwork:259 76 60 136 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 156, Summer CFM: 156 5,359 4,287 879 5,166 Humidification (Winter) 16.86 gal/day :6,182 0 0 0 Total Building Load Totals:44,432 6,694 23,382 30,076 Check Figures Total Building Supply CFM:1,054 CFM Per Square ft.:0.340 Square ft. of Room Area:3,096 Square ft. Per Ton:1,235 Volume (ft³):25,796 Building Loads Total Heating Required Including Ventilation Air:44,432 Btuh 44.432 MBH Total Sensible Gain:23,382 Btuh 78 % Total Latent Gain:6,694 Btuh 22 % Total Cooling Required Including Ventilation Air:30,076 Btuh 2.51 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17902 Hidden ... eat Calc.rh9 Friday, August 19, 2022, 1:02 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17902 Hidden Creek Trail, Lakeville Eagan, MN 55121 Page 5 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces East Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement 53 60 *64 57 46 56 63 61 1--5 2 Main Level *573 530 458 538 569 547 487 554 5--6 3 Upper Level 428 390 309 400 *431 374 283 374 4--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°East *1,054 *23,382 6,694 *2.51 45°Southeast 980 21,803 6,694 2.37 90°South 831 18,611 6,694 2.11 135°Southwest 996 22,133 6,694 2.40 180°West 1,046 23,203 6,694 2.49 225°Northwest 976 21,725 6,694 2.37 270°North 834 18,680 *6,694 2.11 315°Northeast 988 21,982 6,694 2.39 * Indicates highest value of all rotations. 2.1 2.2 2.3 2.4 2.5 East Southeast South Southwest West Northwest North NortheastCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\17902 Hidden ... eat Calc.rh9 Friday, August 19, 2022, 1:02 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17902 Hidden Creek Trail, Lakeville Eagan, MN 55121 Page 6 Building Rotation Report (cont'd) 22,000 23,000 24,000 25,000 26,000 27,000 28,000 29,000 30,000 31,000 32,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest Front door faces North Front door faces Northeast F:\ ...\17902 Hidden ... eat Calc.rh9 Friday, August 19, 2022, 1:02 PM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014