Loading...
HomeMy WebLinkAboutLA206862 - APPROVED - Bldg Permit App PlansRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov DE Email 9-28-2022 $201.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: X solar X 200.00 1.00 201.00 V-b 2020 IRC-1 RS-3 Rooftop Solar (16 Panels) DP 9/29/22 :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ  6XEMHFW 2EHUJ5HVLGHQFH    WK6W:   /DNHYLOOH01  7R:KRP,W0D\&RQFHUQ  7KHIROORZLQJUHIHUHQFHVWKH2EHUJ5HVLGHQFHLQ/DNHYLOOH01  ([LVWLQJURRIIUDPLQJ 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUW DOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDG PRGXOHVSOXVPRXQWLQJKDUGZDUH  SVIJURXQGVQRZORDG SVIURRIPDWHULDOV SVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV  ([SRVXUH&DWHJRU\%PSKZLQG VHF   7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG  7KDQN\RX  :HVWVKRUH'HVLJQ(QJLQHHUV            -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU  '0DLQOLQH'U  :HVWILHOG0$  'DWH6HSWHPEHU 5HI  Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 09/29/2022dpfannenstein Provide copy of city approved plans on the job site for the inspector UMCBACDMSP ~98.25'~145.87'~98.25'~145.87' 38'-3"32'-2"16'-7"55'-2"SITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMEDAVID OBERG 9554 208TH ST W, LAKEVILLE, MN 55044 USA APN# 227585703160 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359METER NUMBER : 13623236CASE NUMBER : NAUTILITY PHONE NUMBER FORSHUTDOWN : (800) 895-4999TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309SITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:A. ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC.SHALL NOT BE INSTALLED WITHIN 3’ OF THEGAS METERS’ SUPPLY OR DEMAND PIPING.NOTES:1. LOCATION OF SERVICE PANEL AND ELECTRICALEQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE.2. LOCATION OF SERVICE PANEL AND ADDITIONALELECTRICAL EQUIPMENT NOT DRAWN TO SCALE.3. PV INTERCONNECTION IS A SECONDARYINTERCONNECTION4. AC DISCONNECT IN READILY ACCESSIBLE LOCATIONWITHIN 10' OF MAIN READILY SERVICEMETER/BI-DIRECTIONAL METER. 24/7 UNESCORTEDKEYLESS ACCESS TO BE PROVIDED FOR UTILITY ACDISCONNECT & BI-DIRECTIONAL METER.5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEWITH NEC 690 AND POSTED WITH APPLICABLEWARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10,690-17, & 690-64 (b)(5).6. THERE ARE NO CLEARANCE ISSUES DUE TOOVERHEAD POWERLINES.LABELS LOCATED ON BI- DIRECTIONAL METER, ACDISCONNECT (S), INVERTER(S), AND APPROPRIATELABELS ON MAIN ELECTRIC SERVICE. ALL LABELS AREPERMANENT, WEATHERPROOF.INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ7A-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45AOPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METER(16) REC SOLAR REC400AA PURE BLACK (400W) MODULES(16) ENPHASE IQ7A-72-2-US MICRO-INVERTERS(02) BRANCHES OF 08 MODULES CONNECTED IN PARALLELDISTANCESSOLAR PANELS - INVERTERS: 2'INVERTERS - IQ COMBINER PANEL: 55' MAXIQ COMBINER PANEL - UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT - MAIN ELECTRIC SERVICE: 2' MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 2'208TH ST WTWO- STORYHOUSE(E) STRUCTURE(E) TREES (TYP.)(E) FENCEROOF #1(16) REC SOLAR REC400AA PUREBLACK (400W) MODULES(E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 3(E) 150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER (INSIDE)(N) 60A UTILITY NON-FUSED ACDISCONNECT VISIBLE-OPEN TYPE,LOCKABLE, READILY ACCESSIBLEEXISTINGPATHWAYPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEINDIA AVE.No less than 18 inch clearsetback is required on bothsides of a horizontal ridgeor hipFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode09/29/2022dpfannenstein 2'-5"12'-5"1'-2"2'-0"21'-8"21'-8"UMCBACDMSP REVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMEDAVID OBERG 9554 208TH ST W, LAKEVILLE, MN 55044 USA APN# 227585703160 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359 METER NUMBER : 13623236 CASE NUMBER : NAUTILITY PHONE NUMBER FOR SHUTDOWN : (800) 895-4999 TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309ROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"1MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 16 MODULESMODULE TYPE = REC SOLAR REC400AA PURE BLACK (400W) MODULESMODULE WEIGHT = 45.0 LBS / 20.5 KG.MODULE DIMENSIONS = 71.7"X 40.0" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSF(E)2"X4" TRUSSES @ 24" O.C. (TYP.)NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS & TRUSSES(OR SEAM) LOCATIONS MAY VARY. INSTALL PERMANUFACTURER(S) INSTALLATION GUIDELINES ANDENGINEERED SPANS FOR ATTACHMENTSLEGENDUM- UTILITY METERMSP- MAIN SERVICE PANELACD- AC DISCONNECTCB- COMBINER BOX- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT-TRUSSESR324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:1921 sqftAREA OF ARRAYS:71.7"X 40.0" ( PANEL DIMENSIONS)71.7"X 40.0" = 19.92 sqft (PER PANEL)19.92 sqftpanel X 16 panels = 318.67 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(318.67 sqft / 1921 sqft)(100)= 16.59%∴ THE PANELS USE 16.59% OFTHE TOTAL ROOF AREA3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAYBILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONRAIL16SNAPNRACK UR-40 RAILSPLICE08RAIL SPLICEMID CLAMP24 MODULE MID CLAMPEND CLAMP16MODULE END CLAMPATTACHMENT 52 SNAPNRACK SPEEDSEAL DECKFOOTGROUNDING LUG 04 GROUNDING LUGROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#120° 180°2"X4"24" O.C.18" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY 208TH ST WFRONT YARD71.7"40.0"PHOTOVOLTAIC MODULESREC SOLAR REC400AA PURE BLACK(400W)REAR YARD(N) (52) SNAPNRACK SPEEDSEAL DECKFOOTATTACHMENTS SPACED AT 48" O.C.(N)SNAPNRACK UR-40 RAILROOF #1(16)REC SOLAR REC400AA PUREBLACK (400W) MODULES(E)COMP SHINGLE ROOF (TYP.)36" FIRE PATHWAY (E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 3(E)150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER (INSIDE)(N) 60A UTILITY NON-FUSED ACDISCONNECT VISIBLE-OPEN TYPE,LOCKABLE, READILY ACCESSIBLEINDIA AVE. REVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMEDAVID OBERG 9554 208TH ST W, LAKEVILLE, MN 55044 USA APN# 227585703160 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359 METER NUMBER : 13623236 CASE NUMBER : NAUTILITY PHONE NUMBER FOR SHUTDOWN : (800) 895-4999 TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309ATTACHMENTDETAILSNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOFMOUNTING ONTO WOOD DECKING5REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLERAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"NUMBER ON THIS DRAWING(X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBEDFULLY INTO WOOD DECKREFER TO SNAPNRACK INSTALLATION MANUAL FOR 5HARDWARE TORQUE SPECIFICATIONS16"RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT.SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THESLOPE OF THE ROOFFOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACKDETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENTDETAIL, ULTRA RAIL LEVELING SPACER"SNAPNRACK, SPEEDSEALDECKFOOT BASE, SEALINGSNAPNRACK, UR MOUNTTHRUSNAPNRACK, UR MOUNTTAPPEDEXPLODEDSNAPNRACK, ULTRA RAILTOPCOMP SHINGLE ROOFING, TYP.3.86016"-18 X 13COIL SPRING FOR 34" BOLT,SERRATED FLANGE, S.S.8"BOLT, S.S. (OPTIONAL)5.200MODULE HEIGHT, MAX:UR-40 = 438"COMP SHINGLE ROOFING, TYP.ROOF DECKING, TYP.SCREW HEIGHTOFF ROOF:916"112"158"UR-40 RAILFOR USE WITH SNAPNRACK ULTRA SERIES RAILSMINIMUM DECK THICKNESS:PLYWOOD:15/32"ATTACHMENT DETAILSECTION VIEWOSB: 716"(4X) #14 FULLY THREADEDWOOD SCREW. S.S. MUST EMBEDFULLY INTO WOOD DECKINSTALLATION OVERVIEWROOF DECKING, TYP. 20'-0"20'-4"24'-0"25'-0"REVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMEDAVID OBERG 9554 208TH ST W, LAKEVILLE, MN 55044 USA APN# 227585703160 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359METER NUMBER : 13623236CASE NUMBER : NAUTILITY PHONE NUMBER FORSHUTDOWN : (800) 895-4999TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309ELEVATION PLANWINDOW, (TYP.)WEST SIDEELEVATION PLANSCALE: NTS1(N) PV MODULES DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, BONDING MID CLAMP 242-02050, 242-02051, 242-02052, 242-02053, 242-02054, 242-02055, 242-02056, 242-02057 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL 800 2400 10+ LB-FT UL 2703, FILE E359313 0.16 - 0.18 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM 5/16IN-18 SS HCS BOLT, LENGTH VARIES, CLEAR / BLACK11 5/16IN SS SPLIT LOCK WASHER, CLEAR / BLACK12 SNAPNRACK, BONDING MID CLAMP, CLEAR / BLACK13 SNAPNRACK, BONDING CHANNEL NUT14 SNAPNRACK, MID CLAMP SPRING, SS15 1 2 3 4 5 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, BONDING MID CLAMP 242-02050, 242-02051, 242-02052, 242-02053, 242-02054, 242-02055, 242-02056, 242-02057 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES X 1.75 1.50 .30 1.15 .91.16 .50 1.29 MID CLAMP PROPERTIES SKU BOLT LENGTH (X)FINISH 242-02050 2.25"CLEAR 242-02051 2.50"CLEAR 242-02052 2.75"CLEAR 242-02053 2.25"BLACK 242-02054 2.50"BLACK 242-02055 2.75"BLACK 242-02056 3.00"CLEAR 242-02057 3.00"BLACK .70 .32 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 1.00 4.20 .30 3.25 1.00 1.00SLOT 1.50 2.781.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM .35 1.80 105° DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UNIVERSAL END CLAMP 242-02215 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL 800 2400 10+ LB-FT UL 2703, FILE E359313 0.24 OPTIONS: PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK END CLAMP UNIVERSAL WAVE11 SNAPNRACK, UNIVERSAL END CLAMP WEDGE12 5/16IN X 3/4IN SS FLAT WASHER13 BOLT, HEX CAP, 5/16IN-18 X 1-1/2IN, SS14 SNAPNRACK UEC PULL STRAP15 1 4 3 2 5 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UNIVERSAL END CLAMP 242-02215 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES .98 1.73 1.50 .60 35°.8554° .90 4°1.07 .29 .52 1.00 1.56 .96 .95 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ rec Alphα® pure Black Series Product Specifications α experience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 385 390 395 400 405 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14 Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3 Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9 Power Output - PMAX (Wp)293 297 301 305 309 Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 132 half-cut REC heterojunction cells with lead-free, gapless technology 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm) Weight:45 lbs (20.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:-40 ... +185°F (-40 ... +85°C) Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq ft)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending) ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941