HomeMy WebLinkAboutLA206862 - APPROVED - Bldg Permit App PlansRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
Submit to: permits@lakevillemn.gov
DE Email
9-28-2022
$201.00
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
X solar
X
200.00
1.00
201.00
V-b
2020
IRC-1
RS-3
Rooftop Solar (16 Panels)
DP 9/29/22
:(676+25(
'(6,*1(1*,1((563&
100 GREAT OAKS BLVD. ͿSUITE 115
ALBANY Ϳ NEW YORK Ϳ 12203
:HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ
6XEMHFW 2EHUJ5HVLGHQFH
WK6W:
/DNHYLOOH01
7R:KRP,W0D\&RQFHUQ
7KHIROORZLQJUHIHUHQFHVWKH2EHUJ5HVLGHQFHLQ/DNHYLOOH01
([LVWLQJURRIIUDPLQJ
3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUW
DOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW
5RRI/RDGLQJ
SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH
SVIJURXQGVQRZORDG
SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV
([SRVXUH&DWHJRU\%PSKZLQGVHF
7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV
ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%&
DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ
DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV
VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG
7KDQN\RX
:HVWVKRUH'HVLJQ(QJLQHHUV
-RKQ(LEHUW1LFRODV1LWWL3(
3URMHFW&RRUGLQDWRU3UHVLGHQW
7R $OO(QHUJ\6RODU
'0DLQOLQH'U
:HVWILHOG0$
'DWH6HSWHPEHU
5HI
Concept Approval ONLYSubject to Field Inspection
Inspector Date
2020
MN Bldg
Code
09/29/2022dpfannenstein
Provide copy of city approved plans
on the job site for the inspector
UMCBACDMSP
~98.25'~145.87'~98.25'~145.87'
38'-3"32'-2"16'-7"55'-2"SITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMEDAVID OBERG
9554 208TH ST W,
LAKEVILLE, MN 55044 USA
APN# 227585703160
UTILITY: XCEL ENERGY
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359METER NUMBER : 13623236CASE NUMBER : NAUTILITY PHONE NUMBER FORSHUTDOWN : (800) 895-4999TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309SITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:A. ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC.SHALL NOT BE INSTALLED WITHIN 3’ OF THEGAS METERS’ SUPPLY OR DEMAND PIPING.NOTES:1. LOCATION OF SERVICE PANEL AND ELECTRICALEQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE.2. LOCATION OF SERVICE PANEL AND ADDITIONALELECTRICAL EQUIPMENT NOT DRAWN TO SCALE.3. PV INTERCONNECTION IS A SECONDARYINTERCONNECTION4. AC DISCONNECT IN READILY ACCESSIBLE LOCATIONWITHIN 10' OF MAIN READILY SERVICEMETER/BI-DIRECTIONAL METER. 24/7 UNESCORTEDKEYLESS ACCESS TO BE PROVIDED FOR UTILITY ACDISCONNECT & BI-DIRECTIONAL METER.5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEWITH NEC 690 AND POSTED WITH APPLICABLEWARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10,690-17, & 690-64 (b)(5).6. THERE ARE NO CLEARANCE ISSUES DUE TOOVERHEAD POWERLINES.LABELS LOCATED ON BI- DIRECTIONAL METER, ACDISCONNECT (S), INVERTER(S), AND APPROPRIATELABELS ON MAIN ELECTRIC SERVICE. ALL LABELS AREPERMANENT, WEATHERPROOF.INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ7A-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45AOPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METER(16) REC SOLAR REC400AA PURE BLACK (400W) MODULES(16) ENPHASE IQ7A-72-2-US MICRO-INVERTERS(02) BRANCHES OF 08 MODULES CONNECTED IN PARALLELDISTANCESSOLAR PANELS - INVERTERS: 2'INVERTERS - IQ COMBINER PANEL: 55' MAXIQ COMBINER PANEL - UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT - MAIN ELECTRIC SERVICE: 2' MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 2'208TH ST WTWO- STORYHOUSE(E) STRUCTURE(E) TREES (TYP.)(E) FENCEROOF #1(16) REC SOLAR REC400AA PUREBLACK (400W) MODULES(E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 3(E) 150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER (INSIDE)(N) 60A UTILITY NON-FUSED ACDISCONNECT VISIBLE-OPEN TYPE,LOCKABLE, READILY ACCESSIBLEEXISTINGPATHWAYPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEINDIA AVE.No less than 18 inch clearsetback is required on bothsides of a horizontal ridgeor hipFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode09/29/2022dpfannenstein
2'-5"12'-5"1'-2"2'-0"21'-8"21'-8"UMCBACDMSP
REVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMEDAVID OBERG
9554 208TH ST W,
LAKEVILLE, MN 55044 USA
APN# 227585703160
UTILITY: XCEL ENERGY
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359 METER NUMBER : 13623236 CASE NUMBER : NAUTILITY PHONE NUMBER FOR SHUTDOWN : (800) 895-4999 TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309ROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"1MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 16 MODULESMODULE TYPE = REC SOLAR REC400AA PURE BLACK (400W) MODULESMODULE WEIGHT = 45.0 LBS / 20.5 KG.MODULE DIMENSIONS = 71.7"X 40.0" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSF(E)2"X4" TRUSSES @ 24" O.C. (TYP.)NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS & TRUSSES(OR SEAM) LOCATIONS MAY VARY. INSTALL PERMANUFACTURER(S) INSTALLATION GUIDELINES ANDENGINEERED SPANS FOR ATTACHMENTSLEGENDUM- UTILITY METERMSP- MAIN SERVICE PANELACD- AC DISCONNECTCB- COMBINER BOX- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT-TRUSSESR324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:1921 sqftAREA OF ARRAYS:71.7"X 40.0" ( PANEL DIMENSIONS)71.7"X 40.0" = 19.92 sqft (PER PANEL)19.92 sqftpanel X 16 panels = 318.67 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(318.67 sqft / 1921 sqft)(100)= 16.59%∴ THE PANELS USE 16.59% OFTHE TOTAL ROOF AREA3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAYBILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONRAIL16SNAPNRACK UR-40 RAILSPLICE08RAIL SPLICEMID CLAMP24 MODULE MID CLAMPEND CLAMP16MODULE END CLAMPATTACHMENT 52 SNAPNRACK SPEEDSEAL DECKFOOTGROUNDING LUG 04 GROUNDING LUGROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#120° 180°2"X4"24" O.C.18" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY 208TH ST WFRONT YARD71.7"40.0"PHOTOVOLTAIC MODULESREC SOLAR REC400AA PURE BLACK(400W)REAR YARD(N) (52) SNAPNRACK SPEEDSEAL DECKFOOTATTACHMENTS SPACED AT 48" O.C.(N)SNAPNRACK UR-40 RAILROOF #1(16)REC SOLAR REC400AA PUREBLACK (400W) MODULES(E)COMP SHINGLE ROOF (TYP.)36" FIRE PATHWAY (E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 3(E)150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER (INSIDE)(N) 60A UTILITY NON-FUSED ACDISCONNECT VISIBLE-OPEN TYPE,LOCKABLE, READILY ACCESSIBLEINDIA AVE.
REVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMEDAVID OBERG
9554 208TH ST W,
LAKEVILLE, MN 55044 USA
APN# 227585703160
UTILITY: XCEL ENERGY
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359 METER NUMBER : 13623236 CASE NUMBER : NAUTILITY PHONE NUMBER FOR SHUTDOWN : (800) 895-4999 TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309ATTACHMENTDETAILSNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOFMOUNTING ONTO WOOD DECKING5REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLERAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"NUMBER ON THIS DRAWING(X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBEDFULLY INTO WOOD DECKREFER TO SNAPNRACK INSTALLATION MANUAL FOR 5HARDWARE TORQUE SPECIFICATIONS16"RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT.SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THESLOPE OF THE ROOFFOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACKDETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENTDETAIL, ULTRA RAIL LEVELING SPACER"SNAPNRACK, SPEEDSEALDECKFOOT BASE, SEALINGSNAPNRACK, UR MOUNTTHRUSNAPNRACK, UR MOUNTTAPPEDEXPLODEDSNAPNRACK, ULTRA RAILTOPCOMP SHINGLE ROOFING, TYP.3.86016"-18 X 13COIL SPRING FOR 34" BOLT,SERRATED FLANGE, S.S.8"BOLT, S.S. (OPTIONAL)5.200MODULE HEIGHT, MAX:UR-40 = 438"COMP SHINGLE ROOFING, TYP.ROOF DECKING, TYP.SCREW HEIGHTOFF ROOF:916"112"158"UR-40 RAILFOR USE WITH SNAPNRACK ULTRA SERIES RAILSMINIMUM DECK THICKNESS:PLYWOOD:15/32"ATTACHMENT DETAILSECTION VIEWOSB: 716"(4X) #14 FULLY THREADEDWOOD SCREW. S.S. MUST EMBEDFULLY INTO WOOD DECKINSTALLATION OVERVIEWROOF DECKING, TYP.
20'-0"20'-4"24'-0"25'-0"REVDATEDESCRIPTIONVERSIONUR08/17/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMEDAVID OBERG
9554 208TH ST W,
LAKEVILLE, MN 55044 USA
APN# 227585703160
UTILITY: XCEL ENERGY
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012743483-2PREMISE NUMBER : 303628359METER NUMBER : 13623236CASE NUMBER : NAUTILITY PHONE NUMBER FORSHUTDOWN : (800) 895-4999TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (763) 350-6858 INSPECTOR NAME:NAINSPECTOR PH# :507-381-1791PROJECT MANAGER: LAURA HESSDESIGNER NAME:N/ACUSTOMER PO#:59309ELEVATION PLANWINDOW, (TYP.)WEST SIDEELEVATION PLANSCALE: NTS1(N) PV MODULES
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, BONDING MID CLAMP
242-02050, 242-02051, 242-02052, 242-02053,
242-02054, 242-02055, 242-02056, 242-02057
D.Ryan
Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A
REVISION:
MATERIALS:
DESIGN LOAD (LBS):
ULTIMATE LOAD (LBS):
TORQUE SPECIFICATION:
CERTIFICATION:
WEIGHT (LBS):
6000 SERIES ALUMINUM, STAINLESS STEEL
800
2400
10+ LB-FT
UL 2703, FILE E359313
0.16 - 0.18
OPTIONS:
CLEAR / BLACK ANODIZED
PARTS LIST
DESCRIPTIONQTYITEM
5/16IN-18 SS HCS BOLT, LENGTH VARIES, CLEAR / BLACK11
5/16IN SS SPLIT LOCK WASHER, CLEAR / BLACK12
SNAPNRACK, BONDING MID CLAMP, CLEAR / BLACK13
SNAPNRACK, BONDING CHANNEL NUT14
SNAPNRACK, MID CLAMP SPRING, SS15
1
2
3
4
5
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, BONDING MID CLAMP
242-02050, 242-02051, 242-02052, 242-02053,
242-02054, 242-02055, 242-02056, 242-02057
D.Ryan
Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A
REVISION:
ALL DIMENSIONS IN INCHES
X
1.75
1.50
.30
1.15
.91.16
.50 1.29
MID CLAMP PROPERTIES
SKU BOLT LENGTH (X)FINISH
242-02050 2.25"CLEAR
242-02051 2.50"CLEAR
242-02052 2.75"CLEAR
242-02053 2.25"BLACK
242-02054 2.50"BLACK
242-02055 2.75"BLACK
242-02056 3.00"CLEAR
242-02057 3.00"BLACK
.70
.32
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, ULTRA RAIL COMP KIT
SEE BELOW
mwatkins Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B
REVISION:
MATERIALS:
DESIGN LOAD (LBS):
ULTIMATE LOAD (LBS):
TORQUE SPECIFICATION:
CERTIFICATION:
WEIGHT (LBS):
6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER
405 UP, 788 DOWN, 236 SIDE
2006 UP, 4000 DOWN, 1070 SIDE
12 LB-FT
UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582
0.80
PARTS LIST
DESCRIPTIONPART NUMBERQTYITEM
SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611
SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012
SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613
3
1
2
2
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, ULTRA RAIL COMP KIT
SEE BELOW
mwatkins Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B
REVISION:
ALL DIMENSIONS IN INCHES
11.75
3.25
8.75 .45
6.75
1.00
4.20
.30
3.25
1.00
1.00SLOT
1.50
2.781.78
1.50
.38 .30
1.37
1.62
UMBRELLA L FOOT PROPERTIES
SKU DESCRIPTION
242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER
242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK
COMP FLASHING PROPERTIES
SKU DESCRIPTION
232-01375 COMP FLASHING, 9" X 12", BLACK ALUM
232-01376 COMP FLASHING, 9" X 12", SILVER ALUM
.35
1.80
105°
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, UNIVERSAL END CLAMP
242-02215
D.Ryan
Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A
REVISION:
MATERIALS:
DESIGN LOAD (LBS):
ULTIMATE LOAD (LBS):
TORQUE SPECIFICATION:
CERTIFICATION:
WEIGHT (LBS):
6000 SERIES ALUMINUM, STAINLESS STEEL
800
2400
10+ LB-FT
UL 2703, FILE E359313
0.24
OPTIONS:
PARTS LIST
DESCRIPTIONQTYITEM
SNAPNRACK END CLAMP UNIVERSAL WAVE11
SNAPNRACK, UNIVERSAL END CLAMP WEDGE12
5/16IN X 3/4IN SS FLAT WASHER13
BOLT, HEX CAP, 5/16IN-18 X 1-1/2IN, SS14
SNAPNRACK UEC PULL STRAP15
1
4
3
2
5
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, UNIVERSAL END CLAMP
242-02215
D.Ryan
Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A
REVISION:
ALL DIMENSIONS IN INCHES
.98
1.73
1.50
.60
35°.8554°
.90
4°1.07
.29
.52 1.00
1.56
.96
.95
DESCRIPTION:
PART NUMBER(S):
DRAWN BY:
SNAPNRACK, UR-40 RAIL
232-02449, 232-02450, 232-02451
mwatkins Solar Mounting Solutions
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B
REVISION:
MATERIALS:
DESIGN LOAD (LBS):
ULTIMATE LOAD (LBS):
TORQUE SPECIFICATION:
CERTIFICATION:
WEIGHT (LBS):
6000 SERIES ALUMINUM
N/A
N/A
N/A LB-FT
UL 2703, FILE E359313
5.85
OPTIONS:
CLEAR / BLACK ANODIZED
MILL FINISH
BUNDLES OF 144
BOXES OF 8
ALL DIMENSIONS IN INCHES
UR-40 RAIL
PROPERTIES
SKU FINISH
232-02449 MILL
232-02450 CLEAR
232-02451 BLACK
1.624
1.500
CENTROID
.750
.832
.792
EQUIVALENT PROPERTIES
A0.357 in²
Ixx 0.125 in⁴
Iyy 0.132 in⁴
Sx (TOP)0.150 in³
Sx (BOT)0.158 in³
Sy (LEFT)0.175 in³
Sy (RIGHT)0.175 in³
rec Alphα® pure
Black Series
Product Specifications
α experience
performance
400 wp
20.3 w ft2
ELIGIBLE
LEAD-FREE
rohs cOMPLIANT
www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy
company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality,
innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America,
Europe, and Asia-Pacific.
GR
GR
GR
GR
GR
1821±2.5 [71.7±0.1]
901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3]
1200 [47.2]
30 [1.2]
22.5 [0.9] 671 ±3 [26.4 ±0.12]
11±0.2
[0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02]
6.0±0.2
[0.24±0.01]
28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8]
Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS
WARRANTY
LOW LIGHT BEHAVIOUR
TEMPERATURE RATINGS*
MAXIMUM RATINGS
Irradiance (W/m²)
Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C)
Temperature coefficient of PMAX:-0.26 %/°C
Temperature coefficient of VOC:-0.24 %/°C
Temperature coefficient of ISC:0.04 %/°C
*The temperature coefficients stated are linear values
Standard REC ProTrust
Installed by an REC Certified Solar Professional No Yes Yes
System Size All ≤25 kW 25-500 kW
Product Warranty (yrs)20 25 25
Power Warranty (yrs)25 25 25
Labor Warranty (yrs)0 25 10
Power in Year 1 98%98%98%
Annual Degradation 0.25%0.25%0.25%
Power in Year 25 92%92%92%
See warranty documents for details. Conditions apply
ELECTRICAL DATA Product Code*: RECxxxAA Pure Black
Power Output - PMAX (Wp) 385 390 395 400 405
Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5
Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4
Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56
Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9
Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14
Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3
Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9
Power Output - PMAX (Wp)293 297 301 305 309
Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0
Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72
Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1
Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19
Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production
spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance
800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above.
GENERAL DATA
Cell type:
132 half-cut REC heterojunction cells
with lead-free, gapless technology
6 strings of 22 cells in series
Glass:0.13 in (3.2 mm) solar glass with
anti-reflection surface treatment
Backsheet:Highly resistant polymer (black)
Frame:Anodized aluminum (black)
Junction box:3-part, 3 bypass diodes, IP67 rated
in accordance with IEC 62790
Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²)
in accordance with IEC 62852
IP68 only when connected
Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m)
accordance with EN 50618
Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm)
Weight:45 lbs (20.5 kg)
Origin:Made in Singapore
STC NMOT85
90
95
100
105
200100 300 400 500 600 700 800 900 1000
Operational temperature:-40 ... +185°F (-40 ... +85°C)
Maximum system voltage:1000 V
Maximum test load (front): + 7000 Pa (146 lbs/sq ft)*
Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)*
Max series fuse rating:25 A
Max reverse current:25 A
* See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor)
Product SPECIFICATIONS
REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS
IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending)
ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941