Loading...
HomeMy WebLinkAboutItem 05 Keswick Medical Addition1 City of Lakeville Planning Department Memorandum To : Planning Commission From: Frank Dempsey, AICP, Associate Planner Date: October 12, 2022 Subject: Packet Material for the October 20, 2022 Planning Commission Meeting Agenda Item: Keswick Medical Addition preliminary and final plat Application Action Deadline: January 27, 2023 INTRODUCTION Ross Hedlund of Frauenshuh, Incorporated, representing Hack Family, LLC, has submitted applications for a preliminary plat and final plat of 5.5 acres of property in conjunction with the proposed development of a 44,255 square foot, two story medical office building located at 21074 Keswick Loop, south of 210th Street (CSAH 70) and west of Interstate 35. The medical office building will be constructed by Twin Cities Orthopedics (TCO). TCO has 35 locations including five in Wisconsin. The proposed Lakeville location is anticipated to employ approximately 40 people. The preliminary and final plat plans have been reviewed by Planning Department, Engineering Division and Parks and Recreation Department staff and the Dakota County Plat Commission. EXHIBITS A. Location and Zoning Map B. Aerial Photo C. Project Narrative D. Preliminary Plat (2 Pages) E. Final Plat 2 F. Site Plan G. Grading and Drainage Plan H. Stormwater Plan I. Utility Plan J. Landscape Plan (2 Pages) K. Exterior Elevations and Floor Plans (3 Pages) L. Dakota County Plat Commission letter, dated September 2, 2022 PLANNING A NALYSIS P RELIMINARY AND FINAL PLAT Background. The subject property totals 5.5 acres of which 0.47 acres will be dedicated as public street right-of-way. The parcel was created from the parent parcel that is being developed for United Christian Academy located south of Keswick Loop. Existing Conditions. The subject parcel is an un-platted metes and bounds described property with a moderate south to north slope. A private stormwater basin on the northwest corner of the property was constructed in 2015 with the construction of the Candlewood Suites. Comprehensive Plan. The 2040 Comprehensive Land Use Plan guides the property for commercial development. The proposed TCO use of the property is consistent with the guided commercial land use designation of the property. Zoning. The property is zoned C-3, General Commercial District which allows medical and professional office buildings as a permitted use. Surrounding Land Uses and Zoning North – 210th Street (CSAH 70) South – Keswick Loop and UCA Development (RM-2 and C-3 Districts) East – Compeer Financial Credit Union (C-3 District) West – Candlewood Suites hotel (C-3 District) MUSA. The preliminary and final plat of Keswick Medical Addition is within the current MUSA (Metropolitan Urban Service Area) and can be served with City sanitary sewer, water and storm sewer infrastructure. Premature Subdivision Criteria. A preliminary and/or final plat may be deemed premature if any of the criteria listed in Chapter 10-2-4-1 of the Subdivision Ordinance apply. The criteria are primarily 3 related to the ability to provide sewer, water, storm sewer and transportation facilities. Staff has determined that the Keswick Medical Addition is not a premature subdivision. Lot Requirements. Lots within the C-3 District must provide 20,000 square feet of lot area and 100 feet of lot width as measured at the front setback line. The net area of proposed Lot 1, Block 1, Keswick Medical Addition is 5.08 acres. The lot width at the front setback line along Keswick Loop is 606 feet. Outlot. No outlots are proposed with Keswick Medical Addition. Streets and Access. Keswick Medical Addition abuts two public streets. 210th Street (CSAH 70) is an A-minor arterial roadway under the jurisdiction of Dakota County. Keswick Loop is classified as a major collector roadway. Right-of-way being dedicated for 210th Street (CSAH 70) totals 0.47 acres. No additional right-of-way dedication is required for Keswick Loop. Trails and Sidewalks. A 10-foot wide bituminous trail is located along the south side of 210th Street. United Christian Academy will construct an eight foot wide bituminous trail on the north side of Keswick Loop adjacent to Keswick Medical Addition. TCO will construct a private sidewalk from the parking lot north to the sidewalk abutting the medical office building. Park Dedication. The City’s Park and Open Space Plan does not identify any park land needs in the area of the Keswick Medical Addition preliminary and final plat. Therefore, park dedication requirements are to be satisfied as a cash fee in lieu of land as required by the Subdivision Ordinance. Park dedication fees are due at the time of final plat approval. The park dedication fee is calculated as follows: 5.55 acres - 0.47 acres x $8,078/acre = $41,036.24 Area of Lot 1, Block 1 Less ROW Dedication Commercial Park Total Dedication Fee Rate Tree Preservation. There are no significant trees located on the property. Wetlands. The wetland delineation provided for the development of Candlewood Suites in 2015 identified two wetlands, one of which is on the subject property. No changes or impacts are proposed with the preliminary and final plat of Keswick Medical Addition. Grading and Utilities. Grading, drainage, erosion control and utility plans have been submitted to the Engineering Division for review. Sewer utilities serving the Keswick Medical Addition plat are located along the south side of 210th Street. 4 All grading, drainage and erosion control items must be completed as outlined in the attached October 12, 2022 engineering report. SITE P LAN The TCO building will be situated near the east property line on the site with parking located south and west of the building. Setbacks. Setbacks for buildings and parking within the C-3 District are as follows: Yard Abutting Streets Sides (interior) Parking (abutting streets) Parking (interior) Setback 30 feet 10 feet (east) 15 feet 5 feet The building and parking lot comply with the setback requirements. Access. Site access will be from two driveways at Keswick Loop. The west driveway access will be shared with the Candlewood Suites hotel. Parking. The proposed 44,255 square foot office building requires a minimum of 199 parking spaces at a ratio of one space for each 200 square feet of gross building floor area, minus an allowable 10% floor area credit. Parking requirements are calculated as follows: 44,255 sf – 10% = 39,829 / 200 = 199 parking spaces A total of 214 parking spaces are proposed on the site plan, however, staff recommends that the four parking spaces west of the west driveway entrance drive and three parking spaces at the east side of the east driveway entrance drive be removed to reduce potential traffic conflicts at those driveway entrances. This would reduce the proposed number of parking spaces to 207. The parking aisles, stall width and stall depth all meet the minimum size and dimension requirements of the Zoning Ordinance as follows: Stall Width: Nine feet Stall Depth: 20 feet or 18 feet with a two-foot overhang Aisle Width: 24 feet 5 Building Design/Height. The exterior materials of the building include dark and light brick face and stone inlay architectural pre-cast concrete panels, glazing (glass) (Grade A), precast concrete buff-acid etch as the smooth texture wall materials (Grade B), and pre-finished ornamental metal panels as roof-top mechanical screening (Grade C). The building will be 30 feet tall at the top roof line with a 2 foot tall parapet and an eight foot tall mechanical equipment screening wall. The parapet wall and screening wall are not included in the overall building height. The Zoning Ordinance allows a maximum building height of 35 feet. The proposed building materials and height meet Zoning Ordinance requirements. Trash and Recyclables Storage. The site plan proposes an outdoor trash/recycling container in the northwest corner of the site. The enclosure must be designed in accordance with Zoning Ordinance design standards for height and exterior materials including a durable maintenance free material gate. The architectural plans show an eight foot tall enclosure with foundation and wall materials consistent with the exterior materials on the principal building. Metal wall panels are proposed for the gate material. Landscaping. The landscape plan consists of a mixture of evergreen and deciduous trees and various shrubs throughout the site, parking lot, and building foundation. The plan proposes 23 deciduous trees, five spruce trees, and four ornamental trees including various shrubs and grasses. An in-ground irrigation system for landscaping maintenance is proposed as required by the Zoning Ordinance. The proposed landscaping is consistent with Zoning Ordinance requirements and the Corridor and Gateway Design Study standards. A financial security totaling $30,000 shall be submitted as a condition of final plat approval to guarantee installation of the landscaping per the approved landscape plan. Signage. The property is located in the Freeway Corridor District which allows additional area and height for a freestanding sign. Each commercial property is allowed one freestanding sign (pylon or monument) not to exceed 150 square feet in area for each side and 30 feet in height. Two wall signs up to 150 square feet in area are allowed on a through (double frontage) lot. The sign plan proposes wall signs on the north, south, and east walls of the building. One of the wall signs will have to be removed to comply with Zoning Ordinance requirements. A 10 foot tall monument sign mounted on a three foot tall brick base is proposed near the east driveway entrance. A sign permit is required prior to installation of any signage. Lighting. The exterior lighting plan includes both parking lot and building exterior lighting. All lights will be downcast LED fixtures. The plan includes nine light poles with 11 light fixtures in the parking lot area. Wall mounted canister type light fixtures will be installed on the building to light the building exterior and entrances. The lighting plan and fixtures are comparable to the lighting at Candlewood Suites to the west and Compeer Financial to the east. None of the foot 6 candle measurements exceed 1.0 fc at the public road right-of-way as required by the Zoning Ordinance. RECOMMENDATION Planning Department staff recommends approval of the Keswick Medical Addition preliminary and final plat subject to the following stipulations: 1. The site shall be developed in accordance with the approved preliminary and final plat plans and in compliance with Zoning Ordinance requirements. 2. The site shall be developed in accordance with the recommendations listed in the October 12, 2022 engineering report. 3. The property owner shall be responsible for maintenance of all landscaping, including within the boulevard. A financial security of $30,000 shall be submitted to guarantee installation of the landscaping per the approved landscape plan. 4. Site lighting shall be installed in accordance with the approved lighting plan and shall meet the requirements of the Zoning Ordinance. 5. All signage on the property must meet the requirements of Section 11-23 of the Zoning Ordinance. A sign permit is required prior to the installation of any signs. 6. Snow storage shall not occur within required parking spaces and vehicle driving lanes. 7. Modify the site plan to remove the four parking spaces west of the west driveway entrance drive and three parking spaces at the east side of the east driveway entrance drive prior to City Council consideration of the preliminary and final plat. 8. Prior to City Council consideration, the final plat must be revised to include a permanent drainage and utility easement over the public utilities being extended through the site to serve the UCA Development. I-35210TH ST (CSAH 70) Proposed Location City of Lakeville Zoning Map Keswick Medical Add. EXHIBIT AKEOKUK AVERST-2 C-3 C-3 C-3 RH-2 RA RH-2 P/OS RM-2 C-3 KEOKUK AVEKESWICK LOOP RH-2 C-3 M-1 C-3 Keswick Medical Addition Preliminary and Final Plat Disclaimer: Map and parcel data are believed to be accurate, but accuracy is not guaranteed. This is not a legal document and should not be substituted for a title search,appraisal, survey, or for zoning verification. Map Scale 1 inch = 600 feet 10/3/2022 Project Narrative 6442 City West Parkway, Suite 300, Eden Prairie, MN 55344 952.996.9662 8/1/2022 Twin Cities Orthopedics (TCO) Medical Office Building Lakeville, MN SRa #:21-009 Project Description Twin Cities Orthopedics (TCO) is planning to develop a new medical office building that is located along the South side of County Rd 70 (210th Street West). The medical office building will house Physical Therapy & Athletic Training Services, Hand Therapy Services, Orthopedic Clinic services, and Imaging (see Operation Description below for additional information). The medical office building will be a 2-story building. The total building area is 44,255 sf. The building will be serviced by mechanical roof top units that will be located in a screened area on the roof. The roof will be drained internally with overflow drains that daylight above grade. There is an exterior enclosure for trash and recycling to be collected with easy access for trucks to traverse the site. The site has previously been graded to prepare for building development and there are no significant trees on site. A new landscape plan has been developed and included in the documentation. The overall Floor Area was calculated with a 10% reduction of area as allowed in 11-19-7 for the General Provisions for Ch 19 Off Street Parking Requirements. The site has been designed to allow for patient and staff parking with a total of 214 parking stalls including 8 accessible parking stalls. This provides a total of 5.37 parking stalls per 1,000 SF (44,255 sf x 90% = 39,830 sf/1000 = 39.83 x 5 stalls per 1000 sf = 199.15 or 200 required stalls), which is more than adequate for other TCO locations. Operation Description The facility will house a traditional physical therapy and occupational therapy clinic that supports outpatient ambulatory surgical and non-surgical rehabilitation. These services are conducted in a 1:1 provider (therapist) to patient ratio. The Facility will also be suited for use in areas such as athletic medicine and personal training. These activities may be conducted in 1:1 trainer to client ratio. Twin Cities Orthopedics would expect to have up to 40 employees at the facility in a given day, likely not more than 30 at a time. TCO expects up to 300 total patients a day. Thus, during peak hours of a particular day, we could expect to see up to 80 individuals at the facility. The primary business will occur between the hours of 7 a.m. to 5:30 p.m. Monday through Friday; however, the Facility will likely have certain appointments scheduled as early as 6:00 a.m. and as late as 7:00 pm. One provider will work on Saturdays. The facility will be closed Sundays other than for special appointments. C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 08 /01 / 2022 1:1 PMW:\2022\22267\CADD DATA\SURVEY\_dwg Sheet Files\S22267-PPLATOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDIC 21219 Keokuk Avenue Lakeville, MN 55044 SRA SPERIDES REINER ARCHITECTS 6442 City West Parkway Suite 300 Eden Prairie, MN 55344 License No. Date I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of VICINITY MAP Field Crew Max L. Stanislowski - PLS 48988 Project Lead Drawn By Checked By Loucks Project No. Minnesota. 22267 MLS NJL MLS BRS 08/01/22 08/01/22 SURVEY ISSUED SITE FOUND 1/2 MONUMENT, MARKED "23189" FOUND CAST IRON MONUMENT FOUND PK NAIL TOP NUT HYDRANT HYDRANT UNLESS SHOWN OTHERWISE LEGENDGENERAL NOTES SURVEYOR: Loucks 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55330 763-424-5505 1.Prepared July x, 2022. 2.The address, as disclosed in documents provided to the surveyor, obtained by the surveyor, or observed while conducting the fieldwork is 21219 Keokuk Avenue, Lakeville, MN 55044. 3.The bearings for this survey are based on the Dakota County Coordinate System NAD 83 (1986 Adjust). 3.Benchmark: MnDOT 1980 C 1: At Lakeville, 3.3 miles south of the junction of Trunk Highway 50 and Interstate Highway 35, 1.5 miles north of the Dakota-Scott County line, in the southeast corner of northbound Interstate Highway 35 bridge number 19844 over County Road 64 and a bike path. Elevation = 1062.17 feet (NGVD29) Site Benchmark: Top nut of hydrant on the west side of the property, 186.0± feet north of the bituminous edge of Keswick Loop and 4.6± feet east of the existing back of curb. Elevation = 1115.13 feet (NGVD29) 4.This property is contained in Zone X (areas determined to be outside the 0.2% annual chance floodplain) per Flood Insurance Rate Map No. 27037C0193E, Community Panel No. 2701070193E, effective date of 12/02/11. 5.See sheet 2 for the existing conditions and the proposed site plan overlay. 6.The field work was completed on 06/06/22. OWNER/DEVELOPER: Frauenshuh Commercial Real Estate 7101 West 78th Street, Suite 100 Bloomington, MN 55439 952-829-3480 Current Zoning: XXX Any current zoning classification, setback requirements, height and floor space area restrictions, and parking requirements, shown hereon, are per a report or letter by ________ , dated ____________ , for the subject property are as follows: Any zoning classification, setback requirements, height and floor space area restrictions, and parking requirements, shown hereon, was researched to the best of our ability and is open to interpretation. Per the City of ______________ Zoning Map and City Code, on ________ , information for the subject property is as follows: Current Setbacks: Front XX feet Side XX feet Rear XX feet Height XX feet Proposed Zoning: XXX Proposed Setbacks: Front XX feet Side XX feet Rear XX feet Height XX feet ZONING INFORMATION Areas: Right of Way Dedication Area = 20,333 +/- square feet or 0.47 +/- acres Net Property Area = 221,413 +/- square feet or 5.08 +/- acres Total Property Area = 241,746 +/- square feet or 5.55 +/- acres SITE DATA (Per Schedule A of the herein referenced Title Commitment) That part of the East Half of the Northeast Quarter of Section 35, Township 114, Range 21, Dakota County, Minnesota, described as follows: Beginning at the southeast corner of said East Half of the Northeast Quarter; thence west on the south line thereof a distance of 477.93 feet; thence north parallel with the east line of said East Half of the Northeast Quarter a distance of 435.60 feet; thence west parallel with said south line of the East Half of the Northeast Quarter a distance of 502.92 feet to the east line of the west 329.02 feet of said East Half of the Northeast Quarter; thence north on said east line of the west 329.02 feet a distance of 888.63 feet to the north line of the Southeast Quarter of the Northeast Quarter; thence west on the north line of said Southeast Half of the Northeast Quarter a distance of 329.04 feet to the west line of said East Half of the Northeast Quarter; thence north on said west line a distance of 779.14 feet to the south line of the north 544.50 feet of said East Half of the Northeast Quarter; thence east on said south line of the north 544.50 feet a distance of 280.03 feet to the east line of the west 280.00 feet of said East Half of the Northeast Quarter; thence north on said east line of the west 280.00 feet a distance of 544.55 feet to the north line of said East Half of the Northeast Quarter; thence east on said north line a distance of 370.02 feet to a point 660.00 feet west of the northeast corner of said East Half of the Northeast Quarter; thence south parallel with the east line of said East Half of the Northeast Quarter a distance of 660.06 feet; thence east, parallel with the north line of said East Half of the Northeast Quarter, a distance of 660.00 feet to the east line of said East Half of the Northeast Quarter; thence south on said east line a distance of 1991.62 feet to the point of beginning. That lies northerly of the northerly line of Parcel 31 (identified as Keokuk Avenue) as shown on Dakota County Road Right of Way Map No. 300A. Abstract Property LEGAL DESCRIPTION PRELIMINARY PLAT KESWICK MEDICAL ADDITION 1 OF 2SCALE IN FEET 0 N100 200 PROPOSED PROPERTY DESCRIPTION Lot 1, Block 1, KESWICK MEDICAL ADDITION, Dakota County, Minnesota. 444444444444 4 4 4 8888888888884PROPOSED BUILDING C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 08 /01 / 2022 12:27 PMW:\2022\22267\CADD DATA\SURVEY\_dwg Sheet Files\S22267-PPLATOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDIC 21219 Keokuk Avenue Lakeville, MN 55044 SRA SPERIDES REINER ARCHITECTS 6442 City West Parkway Suite 300 Eden Prairie, MN 55344 License No. Date I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of VICINITY MAP Field Crew Max L. Stanislowski - PLS 48988 Project Lead Drawn By Checked By Loucks Project No. Minnesota. 22267 MLS NJL MLS BRS 08/01/22 08/01/22 SURVEY ISSUED SITE SCALE IN FEET 0 40 80 N PRELIMINARY PLAT KESWICK MEDICAL ADDITION 2 OF 2 PROPOSED PROPERTY DESCRIPTION Lot 1, Block 1, KESWICK MEDICAL ADDITION, Dakota County, Minnesota. BEING 10 FEET IN WIDTH, UNLESS OTHERWISE INDICATED, AND ADJOINING RIGHT-OF-WAY LINES, AND PLAT BOUNDARY LINES, AS SHOWN ON THE PLAT. DRAINAGE AND UTILITY EASEMENTS ARE SHOWN THUS: (NOT TO SCALE) SPOT ELEVATIONSIGN CATCH BASIN CONTOUR CONCRETE CURB STORM SEWER SANITARY SEWER CONCRETE ELECTRIC TRANSFORMER TELEPHONE PEDESTAL ELECTRIC MANHOLE ELECTRIC METER HAND HOLE CULVERT GUARD POST ELEV @ THRESHOLD OUTLET CONTROL STRUCTURE FLARED END SECTION TOP OF CURB FOUND 1/2 MONUMENT, MARKED "23189" FOUND CAST IRON MONUMENT FOUND PK NAIL TOP NUT HYDRANT WATER LINE SERVICE CLEANOUT EXISTING BUILDING STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE UNLESS SHOWN OTHERWISE SANITARY MANHOLE STORM MANHOLE CATCH BASIN MAPPED SANITARY SEWER MAPPED WATERMAIN MAPPED UNDERGROUND FIBER OPTIC MAPPED UNDERGROUND ELECTRIC MAPPED UNDERGROUND GAS LIGHT POLE RIP-RAP LEGEND MAPPED UNDERGROUND UTILITY TE TE TE SPRUCE MAPLE CONIFEROUS TREE DECIDUOUS TREE 1 SCHEDULE B II ITEM STRUCTURE RIM & INVERT TE PROPOSED TEMPORARY EASEMENT INFORMATION AS SHOWN ON PLANS NOT FIELD VERIFIED PROPOSED LEGEND WATERMAIN SANITARY MANHOLE CONCRETE CURB BUILDING NO PARKING SANITARY SEWER SERVICE 3PARKING SETBACK LINE BUILDING SETBACK LINE 3ACCESSIBLE PARKING STALL SURVEY REPORT 1.The purpose of this sheet is to show the proposed Civil Site Plan overlaid onto the existing conditions and the proposed plat. 2.See sheets 1 and 2 for the ALTA/NSPS Land Title Survey. LOUCKS SECTION 35, TOWNSHIP 114, RANGE 21 DAKOTA COUNTY, MINNESOTA VICINITY MAP N NOT TO SCALE (CSAH NO 70) SHEET 2 OF 2 SHEETS 210TH ST W INTERSTATE NO 35215TH ST W KEOKUK AVEKESWICK LOOPSITE BEING 5 FEET IN WIDTH, UNLESS OTHERWISE INDICATED AND ADJOINING LOT LINES, AND BEING 10 FEET IN WIDTH, UNLESS OTHERWISE INDICATED, AND ADJOINING RIGHT-OF-WAY LINES, AND PLAT BOUNDARY LINES, AS SHOWN ON THE PLAT. DRAINAGE AND UTILITY EASEMENTS ARE SHOWN THUS: (NOT TO SCALE) BEARINGS ARE BASED ON THE SOUTH LINE OF THE EAST HALF OF THE NORTHEAST QUARTER OF SECTION 35, TOWNSHIP 114, RANGE 21, HAVING A BEARING OF S89°46'18"W.NDENOTES FOUND "PK NAIL" SCALE IN FEET 0 DENOTES FOUND 1/2 INCH IRON MONUMENT, MARKED "23189", UNLESS OTHERWISE SHOWN (D)DENOTES DEED DISTANCE 100 200 DENOTES FOUND DAKOTA COUNTY MONUMENT NO PARKINGNO PARKINGNO PARKINGNO PARKINGFFE=1112.5 NWL: 1091.0 10-YR: 1093.03 HWL: 1094.11 FILTRATION BASIN BOT: 1091.0 10-YR: 1092.59 HWL: 1093.86 NO PARKINGWETLAND 1 10-YR: 1089.67 100-YR: 1091.31 7 16 99999999 13 13 13 13 3 27 4 8-VAN ACCESSIBLE HC STALLS 20.024.0 20.020.0 24.0 20.020.0 24.0 18.0 18.0 24.0 18.024.0 20.0 20.0 24.0 18.0 10.3 18.024.020.020.024.020.020.024.018.0 TRASH ENCLOSURE 8.0 14.0 TCO 148.9 181.3 24.0 10.0 5.0 5.0 33.0 MONUMENT SIGN 25 RETAINING WALL LIGHT POLE, TYP. CONCRETE APRON 12'x12' CONCRETE TRANSFORMER PAD INGRESS & EGRESS EASEMENT PER DOC. NO. 3086870 SEE PLAT FOR DETAIL ADA RAMP BY OTHERS N SCALE IN FEET 0 30 60 C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 09 /09 / 2022 3:52 PMW:\2022\22267\CADD DATA\CIVIL\_dwg Sheet Files\C2-1 - SITE PLANOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDICS LAKEVILLE, MINNESOTA TCO REAL ESTATE FUND 3 4200 DAHLBERG DRIVE SUITE #300 GOLDEN VALLEY, MN 55422 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 22267 VJV TRG VJV 09-09-22 09-09-22 CITY SUBMITTAL 07-29-22 REVISED CITY SUBMITTAL 09-09-22 C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 STORM WATER POLLUTION PREVENTION PLAN C3-3 STORM WATER POLLUTION PREVENTION NOTES & DETAILS C4-1 UTILITY PLAN C8-1 DETAIL SHEET L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS SITE PLAN C2-1 1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND STATE/LOCAL JURISDICTION REQUIREMENTS. 2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND LOCAL/STATE REQUIREMENTS. 3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. 5.TYPICAL FULL SIZED PARKING STALL IS 9' X 18' UNLESS OTHERWISE NOTED. 6.ALL CURB RADII SHALL BE 5.0' UNLESS OTHERWISE NOTED. 7.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. 8.REFER TO ARCHITECTURAL SITE PLAN FOR BUILDING SETBACKS. SITE NOTES 1.MINNESOTA STATE STATUTE REQUIRES NOTIFICATION PER "GOPHER STATE ONE CALL" PRIOR TO COMMENCING ANY GRADING, EXCAVATION OR UNDERGROUND WORK. 2.THE CONTRACTOR SHALL FIELD VERIFY LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM THE PLANS. 3.THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASE OF THIS PROJECT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGES TO ADJACENT PROPERTIES OCCURRING DURING THE CONSTRUCTION PHASE OF THIS PROJECT. 4.THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TRAFFIC CONTROL DEVICES SUCH AS BARRICADES, WARNING SIGNS, DIRECTIONAL SIGNS, FLAGMEN AND LIGHTS TO CONTROL THE MOVEMENT OF TRAFFIC WHERE NECESSARY. PLACEMENT OF THESE DEVICES SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE APPROPRIATE MINNESOTA DEPARTMENT OF TRANSPORTATION STANDARDS. 5.IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 6.THE DUTY OF THE ENGINEER OR THE DEVELOPER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTORS SAFETY MEASURES IN, OR NEAR THE CONSTRUCTION SITE. 7.BEFORE BEGINNING CONSTRUCTION THE CONTRACTOR SHALL INSTALL EROSION AND SEDIMENTATION CONTROL MEASURES IN ACCORDANCE WITH NPDES PERMIT REQUIREMENTS, BEST MANAGEMENT PRACTICES, STATE AND LOCAL REQUIREMENTS AND THE DETAILS SHOWN ON THE DETAIL SHEET(S) OF THE PROJECT PLANS. 8.ALL CONSTRUCTION PERMITS, APPLICATIONS AND FEES ARE THE RESPONSIBILITY OF THE CONTRACTOR. 9.ALL ENTRANCES AND CONNECTIONS TO CITY STREETS SHALL BE CONSTRUCTED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND NOTIFICATIONS AS REQUIRED. 10.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. 11.ADJUST ALL EXISTING STRUCTURES, BOTH PUBLIC AND PRIVATE TO THE PROPOSED GRADES WHERE DISTURBED AND COMPLY WITH ALL REQUIREMENTS OF THE UTILITY OWNERS. STRUCTURES BEING RESET TO PAVED AREAS MUST MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING. 12.EXISTING TOPOGRAPHY PROVIDED BY LOUCKS INC, TOPOGRAPHIC SURVEY DATED 06-06-22. 13.SUBGRADE PREPARATION SHALL BE PERFORMED IN ACCORDANCE WITH MNDOT 2112. THE TOP 3 FEET SHALL BE COMPACTED TO 100% OF THE STANDARD PROCTOR DENSITY. 14.AGGREGATE BASE SHALL BE MNDOT 2211 CLASS 5. COMPACTION SHALL BE BY THE QUALITY COMPACTION METHOD. 15.PLANT MIXED BITUMINOUS PAVEMENT SHALL BE CONSTRUCTED IN ACCORDANCE WITH MNDOT 2360 WITH MIX DESIGN AS SHOWN ON THE DETAILS. COMPACTION SHALL BE BY THE ORDINARY COMPACTION METHOD. 16.CONCRETE CURB & GUTTER SHALL BE PERFORMED IN ACCORDANCE WITH MNDOT 2531. CURING SHALL BE BY THE MEMBRANE CURING METHOD. EXPANSION JOINTS EVERY 200 FEET AT ALL FIXED OBJECTS. CONTRACTIONS JOINTS EVERY 10 FEET. 17.CONCRETE WALK SHALL BE PERFORMED IN ACCORDANCE WITH MNDOT 2521. CURING SHALL BE BY THE MEMBRANE CURING METHOD. EXPANSION JOINTS AT ALL FIVES OBJECTS. CONTRACTION JLINTS EVERY 5 FEET. 18. WORKING HOURS ARE 7 AM - 7 PM (MONDAY - FRIDAY) AND 9 AM - 7 PM ( SATURDAY.) A 48 HOUR NOTICE IS REQUIRED FOR SATURDAY WORK. 19.THE CONTRACTOR MUST HAVE A CITY LICENSE. 20.A CITY RIGHT-OF-WAY PERMIT IS REQUIRED TO WORKING WITHIN CITY ROW. GENERAL NOTES TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. PARKING SUMMARY INTERIOR STALLS - 9'x20' EXTERIOR STALLS - 9'x18' 206 STALLS 8 HC STALLS 214 TOTAL STALLS PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 PAVEMENT TYPES BITUMINOUS PAVEMENT CONCRETE SIDEWALK HEAVY DUTY BITUMINOUS PAVEMENT NO PARKINGNO PARKINGNO PARKINGNO PARKINGFFE=1112.5 888888888888888888818.14 EX. 17.27 EX. 16.21 EX.15.58 EX. 16.41 18.34 14.35 14.00 14.35 13.70 12.90 14.00 13.70 14.25 14.00 14.55 15.25 14.12 14.64 15.71 EX.15.12 EX.15.54 15.30 13.70 13.67 13.64 13.63 13.60 13.75 13.24 12.9012.90 13.24 14.13 14.13 10.20 11.30 11.55 11.4311.42 10.7511.00 11.90 12.25 12.50 12.15 12.30 12.00 12.1511.85 12.00 11.60 12.50 12.50 12.50 12.25 10.20 10.55 10.8011.15 11.40 10.80 10.2011.30 11.00 11.1511.15 10.20 11.10 10.70 10.50 10.65 12.00 12.20 10.00 10.70 10.20 10.40 10.35 10.50 10.90 9.70 10.10 9.70 11.45 11.3511.20 11.20 10.75 10.75 11.00 10.50 10.50 11.10 10.85 11.15 11.40 11.10 10.10 10.70 10.40 10.40 10.50 10.75 10.75 11.00 12.00 11.59 11.82 12.50 12.50 12.5012.10 11.30 11.20 11.55 11.45 12.00 11.60 10.40 12.25 12.50 12.00 11.75 11.75 11.85 12.25 TW=1106.50 TW=1112.00 TW=1110.40TW=1110.40TW=1110.35 TW=1110.40 TW=1112.20 TW=1110.75TW=1111.25 TW=1110.00 GW=1110.00 GW=1107.00 GW=1100.00 GW=1101.00 GW=1094.00 GW=1094.00 GW=1094.00 GW=1103.50 GW=1105.00 GW=1106.00 1 1 1 0 1110111 2 1 1 1 2 111 4 1 1 1 4 11 1 21112 11.58 11.78 NWL: 1091.0 10-YR: 1093.03 HWL: 1094.11 FILTRATION BASIN BOT: 1091.0 10-YR: 1092.59 HWL: 1093.86 x 1095.4 EOF 2.2%1.1%1.4%0.4%2.9%3.3%3.3%3.3%3.0%NO PARKINGWETLAND 1 10-YR: 1089.67 100-YR: 1091.31 x 1095.5 EOF x 1093.8 EOF N SCALE IN FEET 0 30 60 C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 09 /09 / 2022 3:54 PMW:\2022\22267\CADD DATA\CIVIL\_dwg Sheet Files\C3-1 - GRADING AND DRAINAGE PLANOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDICS LAKEVILLE, MINNESOTA TCO REAL ESTATE FUND 3 4200 DAHLBERG DRIVE SUITE #300 GOLDEN VALLEY, MN 55422 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 22267 VJV TRG VJV 09-09-22 09-09-22 CITY SUBMITTAL 07-29-22 REVISED CITY SUBMITTAL 09-09-22 C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 STORM WATER POLLUTION PREVENTION PLAN C3-3 STORM WATER POLLUTION PREVENTION NOTES & DETAILS C4-1 UTILITY PLAN C8-1 DETAIL SHEET L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS GRADING & DRAINAGE PLAN C3-1 TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 1.SPOT ELEVATIONS REPRESENT FINISHED SURFACE GRADES, GUTTER/FLOW LINE, FACE OF BUILDING, OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2.CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH BASINS IN GUTTERS SHALL BE SUMPED 0.10 FEET. RIM ELEVATIONS SHOWN ON PLANS DO NOT REFLECT SUMPED ELEVATIONS. 3.ALL DISTURBED UNPAVED AREAS ARE TO RECEIVE MINIMUM OF 4 INCHES OF PREMIUM TOP SOIL AND SEED/MULCH OR SOD. THESE AREAS SHALL BE WATERED/MAINTAINED BY THE CONTRACTOR UNTIL VEGETATION IS ESTABLISHED. VERIFY WITH LANDSCAPE PLAN. 4.FOR SITE RETAINING WALLS "TW" EQUALS SURFACE GRADE AT TOP FACE OF WALL (NOT TOP OF WALL), "GW" EQUALS SURFACE GRADE AT BOTTOM FACE OF WALL (NOT BOTTOM OF BURIED WALL COURSES). 5.REFER TO THE REPORT OF GEOTECHNICAL EXPLORATION AND REVIEW FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS. 6.STREETS MUST BE CLEANED AND SWEPT WHENEVER TRACKING OF SEDIMENTS OCCURS AND BEFORE SITES ARE LEFT IDLE FOR WEEKENDS AND HOLIDAYS, OR AS DIRECTED BY CITY. A REGULAR SWEEPING SCHEDULE MUST BE ESTABLISHED. 7.DUST MUST BE ADEQUATELY CONTROLLED. 8.SEE SWPPP FOR ADDITIONAL EROSION CONTROL NOTES AND REQUIREMENTS. 9.SEE UTILITY PLAN FOR WATER, STORM AND SANITARY SEWER INFORMATION. 10.SEE SITE PLAN FOR CURB AND BITUMINOUS TAPER LOCATIONS. 11.A STREET SWEEPER MUST BE AVAILABLE WITHIN 3 HOURS UPON NOTICE FROM THE CITY THAT THE STREETS NEED TO BE SWEPT. 12.THE CONTRACTOR ALONG WITH THE OWNER SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM GOVERNING AUTHORITIES, INCLUDING ANY CITY PERMITS AND THE NPDES PERMIT FROM THE MPCA. 13.INSTALL EROSION CONTROL AND TREE PROTECTION MEASURES BEFORE BEGINNING SITE GRADING ACTIVITIES. SOME EROSION CONTROLS SUCH AS BALE CHECKS AND TEMPORARY SILT PONDS MAY BE INSTALLED AS GRADING OCCURS IN SPECIFIC AREAS. MAINTAIN EROSION CONTROLS THROUGHOUT THE GRADING PROCESS AND REMOVE WHEN TURF HAS BEEN ESTABLISHED. 14.THE CONTRACTOR SHALL ADHERE TO ALL REQUIREMENTS OF THE MPCA NPDES PERMIT. THE AREA TO BE DISTURBED SHALL BE MINIMIZED AND TURF SHALL BE ESTABLISHED WITHIN THE TIME REQUIRED. 15.GRADES SHOWN ARE FINISHED GRADES. 16.FINAL GRADING TOLERANCES ARE +/-0.1 FEET TO FINISH GRADES. 17.UNDER PAVEMENTS COMPACT THE UPPER 3 FEET OF SUBGRADE TO 100% STANDARD PROCTOR DENSITY AT OPTIMUM MOISTURE CONTENT AND 95% STANDARD PROCTOR DENSITY BLOW THE UPPER 3 FEET OF SUBGRADE. OUTSIDE PAVEMENT AREAS COMPACT EMBANKMENTS TO 95% STANDARD PROCTOR DENSITY. 18. WORKING HOURS ARE 7:00 AM - 10:00 PM, MONDAY - SATURDAY. A 48 HOUR NOTICED IS REQUIRED FOR SATURDAY WORK. 19.THE CONTRACTOR MUST HAVE A CITY LICENSE. 20.A CITY RIGHT-OF-WAY PERMIT IS REQUIRED PRIOR TO WORKING WITHIN CITY ROW. 21.TURF REINFORCEMENT MAT (TRM) SHALL BE LANDLOK 450, AS MANUFACTURED BY PROPEX GEOSOLUTIONS, OR APPROVED EQUAL. THE CONTRACTOR SHALL FOLLOW ALL OF THE MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. 22.STRUCTURAL RETAINING WALL, FENCING AND HANDRAIL DESIGN BY OTHERS. REFER TO ARCHITECTURAL PLANS. GRADING, DRAINAGE & EROSION CONTROL SPECIFICATIONS PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 444444444444444 4 4 4 4 NO PARKINGNO PARKINGNO PARKINGNO PARKINGFFE=1112.5 888888888888888888818.14 EX. 17.27 EX. 16.21 EX.15.58 EX. 16.41 18.34 14.35 14.00 14.35 13.70 12.90 14.00 13.70 14.25 14.00 14.55 15.25 14.12 14.64 15.71 EX.15.12 EX.15.30 13.70 13.67 13.64 13.63 13.60 13.75 13.24 12.9012.90 13.24 14.13 14.13 10.20 11.30 11.55 11.4311.42 10.7511.00 11.90 12.25 12.50 12.15 12.30 12.00 12.1511.85 12.00 11.60 12.50 12.50 12.50 12.25 10.20 10.55 10.8011.15 11.40 10.80 10.2011.30 11.00 11.1511.15 10.20 11.10 10.70 10.50 10.65 12.00 12.20 10.00 10.70 10.20 10.40 10.35 10.50 10.90 9.70 10.10 9.70 11.45 11.3511.20 11.20 10.75 10.75 11.00 10.50 10.50 11.10 10.85 11.15 11.40 11.10 10.10 10.70 10.40 10.40 10.50 10.75 10.75 11.00 12.00 11.59 11.82 12.50 12.50 12.5012.10 11.30 11.20 11.55 11.45 12.00 11.60 10.40 12.25 12.50 12.00 11.75 11.75 11.85 12.25 TW=1106.50 TW=1112.00 TW=1110.40TW=1110.40TW=1110.35 TW=1110.40 TW=1112.20 TW=1110.75TW=1111.25 TW=1110.00 4GW=1110.00 GW=1107.00 GW=1100.00 GW=1101.00 GW=1094.00 GW=1094.00 GW=1094.00 GW=1103.50 GW=1105.00 GW=1106.00 1 1 1 0 1110111 2 1 1 1 2 111 4 1 1 1 4 11 1 21112 11.58 11.78 NWL: 1091.0 10-YR: 1093.03 HWL: 1094.11 FILTRATION BASIN BOT: 1091.0 10-YR: 1092.59 HWL: 1093.86 x 1095.4 EOF 2.2%1.1%1.4%0.4%2.9%3.3%3.3%3.3%3.0%NO PARKINGWETLAND 1 10-YR: 1089.67 100-YR: 1091.31 x 1095.5 EOF x 1093.8 EOF INLET PROTECTION TYP ROCK CONSTRUCTION ENTRANCE INLET PROTECTION TYP SILT FENCE SILT FENCE N SCALE IN FEET 0 30 60 C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 09 /09 / 2022 3:55 PMW:\2022\22267\CADD DATA\CIVIL\_dwg Sheet Files\C3-2 - SWPP PLANOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDICS LAKEVILLE, MINNESOTA TCO REAL ESTATE FUND 3 4200 DAHLBERG DRIVE SUITE #300 GOLDEN VALLEY, MN 55422 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 22267 VJV TRG VJV 09-09-22 09-09-22 CITY SUBMITTAL 07-29-22 REVISED CITY SUBMITTAL 09-09-22 C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 STORM WATER POLLUTION PREVENTION PLAN C3-3 STORM WATER POLLUTION PREVENTION NOTES & DETAILS C4-1 UTILITY PLAN C8-1 DETAIL SHEET L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS STORM WATER POLLUTION PREVENTION PLAN C3-2 TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 1.SEE SHEET C3-3 FOR SWPP NOTES AND DETAILS. NOTES SWPPP LEGEND INLET PROTECTION SILT FENCE EXISTING DRAINAGE PATTERN PROPOSED DRAINAGE PATTERN BIO ROLLS EROSION CONTROL BLANKET 444444444444444 4 4 4 4 NO PARKINGNO PARKINGNO PARKINGNO PARKINGFFE=1112.5 88888888888888888884NO PARKING6" C900 PVC WATER CONNECT TO SANI. MH W/AN OUTSIDE DROP AND NEW 6" SERVICE CB RIM= 1110.20 INV= 1106.20 CBMH RIM= 1110.20 INV= 1105.46 124 LF 12 IN RCP @ 0.6%126 LF 15 IN RCP @ 0.6% 12 LF 12 IN RCP @ 0.6% CBMH RIM= 1110.20 INV= 1105.39 CBMH RIM= 1110.20 INV= 1104.63 71 LF 15 IN RCP @ 0.6% CBMH RIM= 1109.70 INV= 1104.20 63 LF 18 IN RCP @ 0.6% CBMH RIM= 1109.70 INV= 1103.82 60 LF 24 IN RCP @ 0.6%CBMH RIM= 1109.70 INV(S)= 1103.46 INV(N)=1094.55 SUMP= 1090.55 31 LF 24 IN RCP @ 5.0% FES= 1093.0 127 LF 12 IN PVC @ 1.0% ROOF LEADER INV= 1105.09 SANITARY SEWER AND WATER LINES TO BE INSTALLED BY OTHERS SANITARY SEWER AND WATER LINES TO BE INSTALLED BY OTHERS 6" COMBINED DOMESTIC AND FIRE SERVICE FDC 45° BEND 6" WET-TAP & GV 43 LF 6" PVC @ 5.0% INV-1103.5 45° BEND 10.3 ADJUST CASTING TO MATCH SITE GRADES INV-1093.24 E INV-1093.34 W ADJUST CASTING TO MATCH SITE GRADES INV-1094.04 E INV-1094.14 S ADJUST CASTING TO MATCH SITE GRADES INV-1095.03 N INV-1095.13 S LIGHT POLE, TYP. LIGHT POLE, TYP. ADJUST CASTING TO MATCH SITE GRADES INV-1095.86 N INV-1095.96 S PROPOSED EASEMENT N SCALE IN FEET 0 30 60 C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 09 /09 / 2022 4:3 PMW:\2022\22267\CADD DATA\CIVIL\_dwg Sheet Files\C4-1 - UTILITY PLANOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDICS LAKEVILLE, MINNESOTA TCO REAL ESTATE FUND 3 4200 DAHLBERG DRIVE SUITE #300 GOLDEN VALLEY, MN 55422 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 22267 VJV TRG VJV 09-09-22 09-09-22 CITY SUBMITTAL 07-29-22 REVISED CITY SUBMITTAL 09-09-22 C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 STORM WATER POLLUTION PREVENTION PLAN C3-3 STORM WATER POLLUTION PREVENTION NOTES & DETAILS C4-1 UTILITY PLAN C8-1 DETAIL SHEET L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS UTILITY PLAN C4-1 TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. UTILITY NOTES 1.BACKGROUND INFORMATION IS BASED ON A FIELD SURVEY BY LOUCKS AND RECORD UTILITY DRAWINGS FROM THE CITY. LOUCKS DOES NOT GUARANTEE THE ACCURACY OF INFORMATION PROVIDED BY OTHERS. 2.ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS, THE MINNESOTA PLUMBING CODE, THE CITY AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 2013 EDITION. HDPE PIPE CONNECTIONS INTO ALL CONCRETE STRUCTURES SHALL BE MADE WITH WATER TIGHT MATERIALS, UTILIZING AN A-LOK OR WATERSTOP GASKET OR BOOT, CAST-IN-PLACE RUBBER BOOT, OR APPROVED EQUAL. WHERE THE ALIGNMENT PRECLUDES THE USE OF THE ABOVE APPROVED WATERTIGHT METHODS, CONSEAL 231 WATERSTOP SEALANT, OR APPROVED EQUAL WILL ONLY BE ALLOWED AS APPROVED BY THE ENGINEER. ALL SANITARY SEWER MAIN LINE SHALL BE SDR 35. 3.SEE SHEETS C8-3 AND THE CONTRACT SPECIFICATIONS FOR SPECIFIC UTILITY DETAILS AND UTILITY SERVICE DETAILS. 4.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL PER THE REQUIREMENTS OF THE CITY. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION. 5.THE CONTRACTOR SHALL NOTIFY GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS PRIOR TO PERFORMING ANY EXCAVATION OR UNDERGROUND WORK. 6.ADJUST ALL EXISTING STRUCTURES, BOTH PUBLIC AND PRIVATE TO THE PROPOSED GRADES WHERE DISTURBED AND COMPLY WITH ALL REQUIREMENTS OF THE UTILITY OWNERS. STRUCTURES BEING RESET TO PAVED AREAS MUST MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING. 7.PROPOSED PIPE MATERIALS: 7.1.WATER SERVICE 6" PVC C900 7.5' BURY DEPTH, ASTM D1785, ASTM D 2464 7.2.SANITARY SERVICE 6" PVC SCHEDULE 40 SERVICE, ASTM D2665 8.STORM SEWER PIPE SHALL MEET OF EXCEED AASHTO M294 MINIMUM PIPE STIFFNESS PER ASTM D2412 60PSI FOR 8"-18". 9.PROPOSED GAS, TELEPHONE & ELECTRIC SERVICES ARE APPROXIMATE LOCATIONS ONLY. COORDINATE EACH SERVICE WITH THE UTILITY OWNER AND GENERAL CONTRACTOR. IF ANY PROPOSED SERVICE LOCATION VARY SIGNIFICANTLY OR CONFLICT, THE ENGINEER MUST BE NOTIFIED PRIOR TO THE INSTALLATION OF THE SERVICE. 10.THE REMOVAL OF EXISTING SERVICES WITHIN THE CONSTRUCTION LIMITS SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AND UTILITY OWNER. ADDITIONAL SERVICES MAY EXIST. 11.ALL WATER SERVICES MUST BE INSTALLED AT A 7.5-FT BURY DEPTH. 11.1.INSULATE ALL CROSSINGS INVOLVING WATER AND SEWER WITH SEPARATION OF 18" OR LESS. 12.PVC SANITARY SEWERS MUST MEET ONE OF THE FOLLOWING ASTM STANDARDS: D3034, F789, D2665, OR F891. ASTM D2241 PIPE MAY BE USED FOR SEWERS 6-INCH AND LARGER. THE INSTALLATION MUST COMPLY WITH ASTM D2321, WHICH REQUIRES INSTALLATION BY OPEN TRENCH ON A CONTINUOUS GRANULAR BED (SEE CURRENT MINNESOTA RULES, PART 4714). 13.RCP STORM SEWERS MUST COMPLY WITH ASTM C76 (SEE CURRENT MINNESOTA RULES, PART 4714). 14.HIGH-DENSITY POLYETHYLENE (HDPE) STORM DRAINS MUST COMPLY WITH CURRENT MINNESOTA RULES, PART 4714: 14.1.PIPES 4-INCH TO 10-INCH IN SIZE MUST COMPLY WITH AASHTO M252. 14.2.PIPES 12-INCH TO 60-INCH IN SIZE MUST COMPLY WITH ASTM F2306. 14.3.ALL FITTINGS MUST COMPLY WITH ASTM D3212. 14.4.WATER-TIGHT JOINTS MUST BE USED AT ALL CONNECTIONS INCLUDING STRUCTURES. 15.ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT (SEE CURRENT MINNESOTA RULES, PART 4714). APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, AND OTHER STRUCTURES. 16.WATER SERVICE LINES MUST BE INSTALLED AT LEAST 10-FEET HORIZONTALLY FROM ANY MANHOLE, CATCHBASIN, OR OTHER SOURCE OF CONTAMINATION, MEASURED FROM OUTER EDGE OF THE PIPE TO THE OUTER EDGE OF THE CONTAMINATION SOURCE (SEE CURRENT MINNESOTA RULES, PART 4714). 17.THE BOTTOM OF WATER SERVICE PIPES LOCATED WITHIN 10-FEET OF THE SEWER CROSSING MUST BE AT LEAST 12-INCHES ABOVE THE TOP OF THE SEWER. WHEN THIS IS NOT FEASIBLE, THE SEWER PIPE MUST BE CONSTRUCTED OF MATERIALS LISTED IN CURRENT MINNESOTA RULES, PART 4714. THE WATER SERVICE SHOULD NOT CONTAIN ANY JOINTS OR CONNECTIONS WITHIN 10-FEET OF A CROSSING. 18.ALL PORTIONS OF THE STORM SEWER SYSTEM LOCATED WITHIN 10-FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED IN ACCORDANCE WITH CURRENT MINNESOTA RULES, PART 4714. 4444444444444444 4 4 4 4 NO PARKINGNO PARKINGNO PARKINGNO PARKING888888888888888888841 1 1 0 1110111 2 1 1 1 2 111 4 1 1 1 4 1112 11 1 21112NWL: 1091.0 10-YR: 1093.03 HWL: 1094.11 FILTRATION BASIN BOT: 1091.0 10-YR: 1092.59 HWL: 1093.86 NO PARKINGWETLAND 1 10-YR: 1089.67 100-YR: 1091.31 TCO 18" MAINTENANCE STRIP WITH ROCK MULCH AROUND BUILDING 18" MAINTENANCE STRIP WITH ROCK MULCH AROUND ENTIRE RETAINING WALL - BOTH TOP AND BOTTOM OF WALL ROCK MULCH BETWEEN BACK OF CURB AND TOP OF RETAINING WALL SOD (TYP.) SEED (TYP.) SEED (TYP.) SOD (TYP.)SOD (TYP.) LIGHT POLES (TYP.) WOOD MULCH (TYP.) SOD (TYP.) SEED (TYP.) WOOD MULCH (TYP.) ENTRY SIGN PLANTINGS ORNAMENTAL TREE (TYP.) CONIFEROUS TREE (TYP.) OVERSTORY TREE (TYP.) FRONT ENTRY PLANTINGS EDGER (TYP.) EDGER (TYP.) IRRIGATION LIMITS (TYP.) IRRIGATION LIMITS (TYP.) SOD (TYP.) SOD - PLACE SIX (6') FEET BEHIND BACK OF CURB SEED (TYP.)SOD (TYP.)N SCALE IN FEET 0 30 60 C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 09 /09 / 2022 12:47 PMW:\2022\22267\CADD DATA\LANDSCAPE\_dwg Sheet Files\L1-1 - LANDSCAPE PLANOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDICS LAKEVILLE, MINNESOTA TCO REAL ESTATE FUND 3 4200 DAHLBERG DRIVE SUITE #300 GOLDEN VALLEY, MN 55422 CITY SUBMITTAL 07-29-22 REVISED CITY SUBMITTAL 09-09-22 C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 STORM WATER POLLUTION PREVENTION PLAN C3-3 STORM WATER POLLUTION PREVENTION NOTES & DETAILS C4-1 UTILITY PLAN C8-1 DETAIL SHEET L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. Project Lead Drawn By Checked By Loucks Project No. Chad E. Feigum - LA 46508 22267 VJV CEF CEF 09-09-22 09-09-22 LANDSCAPE PLAN L1-1 TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. GENERAL NOTES: CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID. HE SHALL INSPECT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS RELATING TO THE NATURE AND SCOPE OF WORK. VERIFY LAYOUT AND ANY DIMENSIONS SHOWN AND BRING TO THE ATTENTION OF THE LANDSCAPE ARCHITECT ANY DISCREPANCIES WHICH MAY COMPROMISE THE DESIGN AND / OR INTENT OF THE PROJECT'S LAYOUT. ASSURE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS GOVERNING THE WORK OR MATERIALS SUPPLIED. CONTRACTOR SHALL PROTECT ALL EXISTING ROADS, CURBS / GUTTERS, TRAILS, TREES, LAWNS AND SITE ELEMENTS DURING PLANTING OPERATIONS. ANY DAMAGE TO SAME SHALL BE REPAIRED AT NO COST TO THE OWNER. CONTRACTOR SHALL VERIFY ALIGNMENT AND LOCATION OF ALL UNDERGROUND AND ABOVE GRADE UTILITIES. CONTRACTOR TO PROVIDE THE NECESSARY PROTECTION FOR THE UTILITIES BEFORE CONSTRUCTION / MATERIAL INSTALLATION BEGINS. CONTRACTOR TO NOTIFY GENERAL CONTRACTOR OF ANY CONCERNS PRIOR TO INSTALLATION OF PLANTINGS. EXISTING CONTOURS, TRAILS, VEGETATION, CURB / GUTTER AND OTHER EXISTING ELEMENTS BASED UPON INFORMATION SUPPLIED TO LANDSCAPE ARCHITECT BY OTHERS. CONTRACTOR SHALL VERIFY ANY AND ALL DISCREPANCIES PRIOR TO CONSTRUCTION AND NOTIFY LANDSCAPE ARCHITECT OF SAME. THE ALIGNMENT AND GRADES OF THE PROPOSED WALKS, TRAILS AND / OR ROADWAYS ARE SUBJECT TO FIELD ADJUSTMENT REQUIRED TO CONFORM TO LOCALIZED TOPOGRAPHIC CONDITIONS AND TO MINIMIZE TREE REMOVAL AND GRADING. ANY CHANGE IN ALIGNMENT MUST BE APPROVED BY LANDSCAPE ARCHITECT. REFER TO SHEET L2-1 LANDSCAPE DETAILS FOR PLANTING SCHEDULE, PLANTING NOTES, AND IRRIGATION NOTES. LANDSCAPE DATA: ALL EXPOSED GROUND AREAS, INCLUDING STREET BOULEVARDS, AND AREAS NOT DEVOTED TO OFF STREET PARKING, DRIVES, SIDEWALKS, PATIOS OR OTHER SUCH IMPROVEMENTS SHALL BE LANDSCAPED WITH GRASS, SHRUBS, TREES (EXCEPT BOULEVARD PORTIONS OF THE PUBLIC RIGHT OF WAY) OR OTHER ORNAMENTAL LANDSCAPE MATERIALS WITHIN ONE YEAR FOLLOWING THE DATE OF BUILDING OCCUPANCY, AS DETERMINED BY THE CERTIFICATE OF OCCUPANCY. REQUIRED LANDSCAPING FOR NEW COMMERCIAL OR INSTITUTIONAL USES SHALL INCLUDE PLANTINGS AT THE PROPERTY PERIMETER, OFF STREET PARKING PERIMETER LANDSCAPING AND INTERIOR LANDSCAPE PLANTINGS. PLANTINGS PROVIDED: OVERSTORY TREES:23 CONIFEROUS TREES: 5 ORNAMENTAL TREES: 4 SHRUBS:86 ORNAMENTAL GRASSES:32 PERENNIALS:40 DECIDUOUS TREES CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE AE 8 ACCOLADE ELM Ulmus `Morton`B & B 2.5"Cal BO 6 BURR OAK Quercus macrocarpa B & B 2.5"Cal CH 5 COMMON HACKBERRY Celtis occidentalis B & B 2.5"Cal GD2 4 KENTUCKY COFFEETREE ESPRESSO Gymnocladus dioica 'Espresso'B & B 2.5"Cal EVERGREEN TREES CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE BS 5 BLACK HILLS SPRUCE FULL FORM Picea glauca `Densata`B & B 8` HGT ORNAMENTAL TREES CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE SSC 4 SPRING SNOW CRABAPPLE Malus x `Spring Snow`B & B 2"Cal SHRUBS CODE QTY COMMON NAME BOTANICAL NAME MIN CONT MIN SIZE SPACING AH 5 ANNABELLE HYDRANGEA Hydrangea arborescens `Annabelle`5 gal 24" HGT 48" o.c. AD 23 ARCTIC FIRE DOGWOOD Cornus sericea `Artic Fire`5 gal 24" HGT 48" o.c. GF 15 GRO-LOW FRAGRANT SUMAC Rhus aromatica `Gro-Low`5 gal 24" SPRD 48" o.c. LPS 18 LITTLE PRINCESS SPIREA Spirea japonica `Little Princess`5 gal 24" HGT 36" o.c. RGD 9 RED GNOME DOGWOOD Cornus alba sibirica `Red Gnome`5 gal 24" HGT 60" o.c. SNS 6 SNOWMOUND SPIREA Spirea nipponica `Snowmound`5 gal 24" HGT 48" o.c. GRASSES CODE QTY COMMON NAME BOTANICAL NAME MIN CONT MIN SIZE SPACING BBL 9 BIG BLUESTEM Andropogon gerardii 1 gal 24" o.c. LIB 10 LITTLE BLUESTEM Schizachyrium scoparium 1 gal 18" o.c. SSG 16 SHENANDOAH SWITCH GRASS Panicum virgatum `Shenendoah`1 gal 36" o.c. CONIFEROUS SHRUBS CODE QTY COMMON NAME BOTANICAL NAME MIN CONT MIN SIZE SPACING ARJ 7 ARCADIA JUNIPER Juniperus sabina `Arcadia`5 gal 18" SPRD 60" o.c. MJJ 9 MINT JULEP JUNIPER Juniperus chinensis `Monlep`5 gal 18" SPRD 60" o.c. PERENNIALS CODE QTY COMMON NAME BOTANICAL NAME MIN CONT MIN SIZE SPACING ASD 24 APRICOT SPARKLES DAYLILY Hemerocallis x 'Apricot Sparkles'1 gal 18" o.c. RSD 16 RUBY STELLA DAYLILY Hemerocallis x `Ruby Stella`1 gal 24" o.c. GROUND COVERS CODE QTY COMMON NAME BOTANICAL NAME SM 1 2,904 sf ROCK MULCH GREY DRESSER TRAP ROCK 2.5" SIZE, TYPE 804, AT 3" DEPTH FROM ADJACENT FINISHED GRADE WM 1 3,149 sf WOOD MULCH SHREDDED HARDWOOD MULCH SOD/SEED CODE QTY COMMON NAME BOTANICAL NAME SEED 20,628 sf TURF SEED SOD 25,985 sf TURF SOD PLANT SCHEDULE C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he C onsultant . With t he Cons ultant's appr oval, ot hers may be per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 09 /09 / 2022 12:50 PMW:\2022\22267\CADD DATA\LANDSCAPE\_dwg Sheet Files\L2-1 - LANDSCAPE DETAILSOUCKSL CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS TWIN CITIES ORTHOPEDICS LAKEVILLE, MINNESOTA TCO REAL ESTATE FUND 3 4200 DAHLBERG DRIVE SUITE #300 GOLDEN VALLEY, MN 55422 CITY SUBMITTAL 07-29-22 REVISED CITY SUBMITTAL 09-09-22 C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 STORM WATER POLLUTION PREVENTION PLAN C3-3 STORM WATER POLLUTION PREVENTION NOTES & DETAILS C4-1 UTILITY PLAN C8-1 DETAIL SHEET L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. Project Lead Drawn By Checked By Loucks Project No. Chad E. Feigum - LA 46508 22267 VJV CEF CEF 09-09-22 09-09-22 LANDSCAPE DETAILS L2-1 GENERAL NOTES COORDINATE THE PHASES OF CONSTRUCTION AND PLANTING INSTALLATION WITH OTHER CONTRACTORS WORKING ON SITE. NO PLANTING WILL BE INSTALLED UNTIL ALL GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA.ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. REMOVE ALL FLAGGING AND LABELS FROM PLANTS. IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY DEFICIENCIES IN THE PLANT SELECTIONS, SOIL CONDITIONS OR ANY OTHER SITE CONDITION WHICH MIGHT NEGATIVELY AFFECT PLANT ESTABLISHMENT, SURVIVAL OR GUARANTEE, HE MUST BRING THESE DEFICIENCIES TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT AND / OR INSTALLATION. PROTECT ALL EXISTING TREES ON SITE SCHEDULED TO REMAIN. IF EXISTING TREES ARE DAMAGED IN ANY MANNER, ABOVE OR BELOW GROUND IN THE ROOT SYSTEM, AN ASPHALTIC TREE PRUNING PAINT SHOULD BE APPLIED IMMEDIATELY AFTER WOUNDING. SOIL & GROUNDCOVER ALL PLANTING AREAS RECEIVING GROUND COVER, PERENNIALS, ANNUALS, AND / OR VINES SHALL RECEIVE A MINIMUM OF 12" DEPTH OF PLANTING SOIL CONSISTING OF AT LEAST 45 PARTS TOPSOIL, 45 PARTS PEAT OR MANURE AND 10 PARTS SAND. WHERE SOD / SEED ABUTS PAVED SURFACES, FINISHED GRADE OF SOD / SEED SHALL BE HELD 1" BELOW SURFACE ELEVATION OF TRAIL, SLAB, CURB, ETC. SEED ALL AREAS DISTURBED DUE TO GRADING OTHER THAN THOSE AREAS NOTED TO RECEIVE SOD. SEED SHALL BE INSTALLED AND MULCHED AS PER MNDOT SPECS. SOD ALL DESIGNATED AREAS DISTURBED DUE TO GRADING. SOD SHALL BE LAID PARALLEL TO THE CONTOURS AND SHALL HAVE STAGGERED JOINTS. ON SLOPES STEEPER THAN 3:1 OR IN DRAINAGE SWALES, THE SOD SHALL BE STAKED TO THE GROUND. LANDSCAPE CONTRACTOR SHALL VERIFY THAT SOIL AND COMPACTION CONDITIONS ARE ADEQUATE TO ALLOW FOR PROPER DRAINAGE AT AND AROUND THE BUILDING SITE. PLANTINGS INFO ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK, AMERICAN ASSOCIATION OF NURSERYMEN. UNLESS NOTED OTHERWISE, ALL SHRUBS SHALL HAVE AT LEAST 5 CANES AT THE SPECIFIED MINIMUM SHRUB HEIGHT OR WIDTH. ORNAMENTAL TREES SHALL HAVE NO V CROTCHES AND SHALL BEGIN BRANCHING NO LOWER THAN 3' ABOVE ROOT BALL. STREET AND BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER THAN 5' ABOVE FINISHED GRADE. ANY CONIFEROUS TREE PREVIOUSLY PRUNED FOR CHRISTMAS TREE SALES SHALL NOT BE USED. ALL CONIFEROUS TREES SHALL BE FULL FORM, NATURAL TO THE SPECIES, WITHOUT PRUNING. PRIOR TO PLANTING, FIELD VERIFY THAT THE ROOT COLLAR / ROOT FLAIR IS LOCATED AT THE TOP OF THE BALLED & BURLAP TREE. IF THIS IS NOT THE CASE, SOIL SHALL BE REMOVED DOWN TO THE ROOT COLLAR / ROOT FLAIR. WHEN THE BALLED & BURLAP TREE IS PLANTED, THE ROOT COLLAR / ROOT FLAIR SHALL BE EVEN OR SLIGHTLY ABOVE FINISHED GRADE. ALL PROPOSED PLANTS SHALL BE LOCATED AND STAKED AS SHOWN ON PLAN. ADJUSTMENTS IN LOCATION OF PROPOSED PLANT MATERIALS MAY BE NEEDED IN FIELD. SHOULD AN ADJUSTMENT BE ADVISED, THE LANDSCAPE ARCHITECT MUST BE NOTIFIED. PLAN TAKES PRECEDENCE OVER PLANT SCHEDULE IF DISCREPANCIES IN QUANTITIES EXIST. SPECIFICATIONS TAKE PRECEDENCE OVER NOTES. NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL IS REQUESTED OF THE LANDSCAPE ARCHITECT BY THE LANDSCAPE CONTRACTOR PRIOR TO THE SUBMISSION OF A BID AND / OR QUOTATION. WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN CALIPER THAN THE TREE BEING PROTECTED OR QUALITY, HEAVY, WATERPROOF CREPE PAPER MANUFACTURED FOR THIS PURPOSE. WRAP ALL DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12-1 AND REMOVE ALL WRAPPING AFTER 5-1. FERTILIZER ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH A 27-3-3 SLOW RELEASE FERTILIZER MIXED IN WITH THE PLANTING SOIL PER THE MANUFACTURER'S INSTRUCTIONS. PLANTS MAY BE TREATED FOR SUMMER AND FALL INSTALLATION WITH AN APPLICATION OF GRANULAR 27-3-3 AT 6 OZ PER 2.5" CALIPER PER TREE AND 3 OZ PER SHRUB WITH AN ADDITIONAL APPLICATION OF 27-3-3 THE FOLLOWING SPRING IN THE TREE SAUCER. EDGING FOR PLANTING BEDS BLACK METAL EDGER TO BE USED TO CONTAIN SHRUBS, PERENNIALS, AND ANNUALS WHERE BED MEETS SOD / SEED UNLESS NOTED OTHERWISE. PLANTING BED PREPARATION ALL ANNUAL AND PERENNIAL PLANTING BEDS TO RECEIVE 3" DEEP SHREDDED HARDWOOD MULCH WITH NO WEED BARRIER. ALL SHRUB BED MASSINGS TO RECEIVE 3" DEEP SHREDDED HARDWOOD MULCH AND FIBER MAT WEED BARRIER. ALL TREES NOT IN PLANTING BEDS TO RECEIVE 4" DEEP SHREDDED HARDWOOD MULCH RING WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK. SPREAD GRANULAR PRE EMERGENT HERBICIDE (PREEN OR EQUAL) PER MANUFACTURER'S RECOMMENDATIONS UNDER ALL MULCHED AREAS. MAINTENANCE STRIPS TO HAVE EDGER AND ROCK MULCH AS SPECIFIED / INDICATED ON DRAWING OR IN SPECIFICATION. MAINTENANCE STRIPS SHALL BE 18" AROUND BUILDING AND AROUND RETAINING WALLS - BOTH TOP AND BOTTOM OF WALLS. INSPECTION AND WARRANTY CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR THE OWNER ACCEPTANCE INSPECTION OF ALL LANDSCAPE AND SITE IMPROVEMENTS. CONTRACTOR IS RESPONSIBLE FOR ON-GOING MAINTENANCE OF ALL NEWLY INSTALLED MATERIALS UNTIL TIME OF OWNER ACCEPTANCE. ANY ACTS OF VANDALISM OR DAMAGE WHICH MAY OCCUR PRIOR TO OWNER ACCEPTANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL PROVIDE THE OWNER WITH A MAINTENANCE PROGRAM INCLUDING, BUT NOT NECESSARILY LIMITED TO, PRUNING, FERTILIZATION AND DISEASE / PEST CONTROL. CONTRACTOR SHALL GUARANTEE NEW PLANT MATERIAL THROUGH ONE (1) CALENDAR YEAR FROM THE DATE OF OWNER ACCEPTANCE. WARRANTY (ONE (1) FULL GROWING SEASON) FOR LANDSCAPE MATERIALS SHALL BEGIN ON THE DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT AFTER THE COMPLETION OF PLANTING OF ALL LANDSCAPE MATERIALS. NO PARTIAL ACCEPTANCE WILL BE CONSIDERED. TIMING OF INSTALLATION UNLESS NOTED OTHERWISE THE APPROPRIATE DATES FOR SPRING PLANT MATERIAL INSTALLATION AND SEED / SOD PLACEMENT IS FROM THE TIME GROUND HAS THAWED TO JUNE 15. FALL SODDING IS GENERALLY ACCEPTABLE FROM AUGUST 15 - NOVEMBER 1. FALL SEEDING FROM AUGUST 15 - SEPTEMBER 15; DORMANT SEEDING IN THE FALL SHALL NOT OCCUR PRIOR TO NOVEMBER 1. FALL CONIFEROUS PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND DECIDUOUS PLANTING FROM THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE THESE DATES IS NOT RECOMMENDED. ANY ADJUSTMENT MUST BE APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. TREES ARE NOT TO BE PRUNED, REMOVED OR TRANSPLANTED BETWEEN APRIL 15 AND JULY 1. NOTIFY LANDSCAPE ARCHITECT IF THESE DATES ARE UNAVOIDABLE. REFER TO SHEET L1-1 LANDSCAPE PLAN FOR PLANTING LOCATIONS, LANDSCAPE DATA, AND GENERAL NOTES. IRRIGATION NOTES: VERIFY EXISTING / PROPOSED IRRIGATION SYSTEM LAYOUT AND CONFIRM COMPLETE LIMITS OF IRRIGATION PRIOR TO SUPPLYING SHOP DRAWINGS. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN IRRIGATION LAYOUT PLAN AND SPECIFICATION AS A PART OF THE SCOPE OF WORK WHEN BIDDING. THESE SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO ORDER AND / OR INSTALLATION. IT SHALL BE THE LANDSCAPE CONTRACTORS RESPONSIBILITY TO INSURE THAT ALL SODDED / SEEDED AND PLANTED AREAS ARE IRRIGATED PROPERLY, INCLUDING THOSE AREAS DIRECTLY AROUND AND ABUTTING BUILDING FOUNDATION. THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE OWNER WITH AN IRRIGATION SCHEDULE APPROPRIATE TO THE PROJECT SITE CONDITIONS AND TO PLANT MATERIAL GROWTH REQUIREMENTS. IRRIGATION SYSTEM IS NOT TO SPRINKLE ACROSS PAVEMENT NOR SHALL THE SYSTEM SPRINKLE THE BUILDING. THE SYSTEM SHALL INCORPORATE A RAIN SENSOR INTO IRRIGATION SYSTEM. PLANTINGS OUTSIDE THE LIMITS OF IRRIGATION ARE TO BE WATERED REGULARLY UNTIL PLANTING / SOD / SEED HAS BEEN ESTABLISHED. LANDSCAPE INSTALLATION: LOUCKS Deciduous Tree Planting.dwgN.T.S. 2x ROOT BALL WIDTH NOTE: CONTRACTOR IS RESPONSIBLE FOR TESTING PERCOLATION RATES PRIOR TO PLANTING. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF POOR DRAINAGE EXISTS. DECIDUOUS TREE PLANTING SET PLANT ON UNDISTURBED NATIVE SOIL SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING EDGE VARIES WOOD STAKE BACKFILL WITH IN SITU TOPSOIL MULCH - 4" DEEP. NO MULCH IN CONTACT WITH TRUNK - SEE NOTES OR SPECS. ROOT FLARE EVEN WITH OR JUST ABOVE GRADE SAFETY FLAGGING - ONE PER WIRE TREE WRAP TO FIRST BRANCH 16"X2" POLYPROPYLENE OR POLYETHYLENE STRAP NOTES: THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL TREES IN A PLUMB POSITION THROUGH THE WARRANTY PERIOD. STAKING IS SUGGESTED, BUT NOT REQUIRED. ANY STAKING MUST CONFORM WITH PRACTICES AS DEFINED IN A.N.A. GUIDELINES FOR STANDARD PRACTICES. PRUNE DAMAGED AND CROSSING BRANCHES AFTER PLANTING IS COMPLETE. CUT BACK WIRE BASKET. WATER TREE THOROUGHLY DURING PLANTING OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND SATURATE SOIL WITH WATER. DO NOT COMPACT MORE THAN NECESSARY TO MAINTAIN PLUMB. 1 CONIFEROUS TREE PLANTING LOUCKS Coniferous Tree Planting.dwgN.T.S. 2 x ROOT BALL WIDTH NOTE: CONTRACTOR IS RESPONSIBLE FOR TESTING PERCOLATION RATES PRIOR TO PLANTING. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF POOR DRAINAGE EXISTS. ROOT BALL SET ON UNDISTURBED SUBGRADE SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING EDGE VARIES - SEE PLAN WOOD STAKE (OPTIONAL) BACKFILL WITH IN SITU TOPSOIL MULCH - 4" DEEP - SEE NOTES OR SPECS. MULCH MUST NOT BE IN CONTACT WITH TRUNK. SAFETY FLAGGING - ONE PER WIRE 16" x2" POLYPROPYLENE OR POLYETHYLENE STRAP NOTES: THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL TREES IN A PLUMB POSITION THROUGH THE WARRANTY PERIOD. STAKING IS SUGGESTED, BUT NOT REQUIRED. ANY STAKING MUST CONFORM WITH PRACTICES AS DEFINED IN A.N.A. GUIDELINES FOR STANDARD PRACTICES. PRUNE ANY DAMAGED BRANCHES AFTER PLANTING IS COMPLETE. WATER TREE THOROUGHLY DURING PLANTING OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND SATURATE SOIL WITH WATER. DO NOT COMPACT MORE THAN NECESSARY TO MAINTAIN PLUMB. 2 REFER TO PLAN 18" MIN. LOOSEN ROOTS OF ALL CONTAINERIZED PLANTS. SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTINGBUILDING WALL (TYP)SHRUB PLANTING LOUCKS Shrub Planting.dwgN.T.S. EDGE VARIES - REFER TO PLAN EDGING MATERIAL - SEE NOTES OR SPEC. LANDSCAPE FABRIC - SEE NOTES OR SPEC. MULCH - 3" DEPTH - SEE NOTES OR SPEC. PLANTING SOIL - SEE NOTES OR SPEC. SHRUBS TO BE PLACED SO THAT TOP OF CONTAINER SITS FLUSH WITH PROPOSED GRADE 3 VARIES SEE PLAN NOTE: LOOSEN ROOTS OF PLANT MATERIAL PRIOR TO PLANTING PERENNIAL PLANTING LOUCKS Perennial Planting.dwgN.T.S.BUILDING WALL (TYP)12" DEPTH (MIN) LOAM PLANTING SOIL SEE NOTES EDGE VARIES - REFER TO PLAN EDGING MATERIAL - SEE NOTES MULCH - 3" MIN. DEPTH - SEE NOTES 4 LEVEL 1 100' -0" LEVEL 2 115' -0" ROOF 130' -0" FIELDHOUSE ROOF 125' -0" PC-3PRECAST CONCRETE - BUFF -FORMLINER PC-2PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT BPC-2 PRECAST CONCRETE - THIN BRICK -IVORY BLEND ASF-1 ALUMINUM FRAMED STOREFRONT - THERMALLY BROKEN PFMF-2PRE-FINISHED METAL FLASHING -DARK GRAY PC-1 PRECAST CONCRETE - BUFF -ACID ETCH MPC-1 METAL PANEL - VANCOUVER COPPER MP-1 4" CORRUGATED T15 METAL WALL PANEL 63 SF SIGNAGE AREA 5' - 0"4' - 0"25' - 0"1' - 0"35' - 0"33' - 0"MPC-2METAL PANEL -BLACK PC-3PRECAST CONCRETE - BUFF -FORMLINER BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PFMF-2PRE-FINISHED METAL FLASHING -DARK GRAY PC-2PRECAST CONCRETE - BUFF -SANDBLAST ACW-1GLAZED ALUMINUM CURTAIN WALL ACW-1 GLAZED ALUMINUM CURTAIN WALL PFMF-3 PRE-FINISHED METAL FLASHING -SHERWIN WILLIAMS NOMADIC DESERT 6107 2' - 0"13' - 0"14' - 0"4' - 0"LEVEL 1 100' -0" LEVEL 2 115' -0" ROOF 130' -0" FIELDHOUSE ROOF 125' -0" PC-3PRECAST CONCRETE - BUFF -FORMLINER PC-2PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT BPC-2 PRECAST CONCRETE - THIN BRICK -IVORY BLEND ASF-1 ALUMINUM FRAMED STOREFRONT - THERMALLY BROKEN PFMF-2PRE-FINISHED METAL FLASHING -DARK GRAY PC-1PRECAST CONCRETE - BUFF -ACID ETCH MPC-1METAL PANEL - VANCOUVER COPPER ACW-1GLAZED ALUMINUM CURTAIN WALL 35' - 0"5' - 0"29' - 0"1' - 0"35' - 0"2' - 0"5' - 0"8' - 0"14' - 0"4' - 0"33' - 0"MP-1 4" CORRUGATED T15 METAL WALL PANEL MPC-2 METAL PANEL -BLACK PC-3 PRECAST CONCRETE - BUFF -FORMLINER BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PFMF-2 PRE-FINISHED METAL FLASHING -DARK GRAY PC-2 PRECAST CONCRETE - BUFF -SANDBLAST ACW-1 GLAZED ALUMINUM CURTAIN WALL PFMF-3 PRE-FINISHED METAL FLASHING -SHERWIN WILLIAMS NOMADIC DESERT 6107 24' - 9 1/2"2' - 8"4' - 1 1/2"14' - 0"4' - 0"LT-1 6" ROUND 2 DIRECTION WALL MOUNT LIGHT 4' - 0"4' - 0"8' - 0"7' - 0"6"PC-2PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PC-3PRECAST CONCRETE - BUFF -FORMLINER MPC-2METAL PANEL -BLACK MP-14" CORRUGATED T15 METAL WALL PANEL 4' - 0"4' - 0"8' - 0"PC-2 PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PC-3 PRECAST CONCRETE - BUFF -FORMLINER MPC-2 METAL PANEL -BLACK 4' - 0"4' - 0"8' - 0"PC-3 PRECAST CONCRETE - BUFF -FORMLINER PC-2 PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT MPC-2 METAL PANEL -BLACK PC-2PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PC-3PRECAST CONCRETE - BUFF -FORMLINER MPC-2METAL PANEL -BLACK 4' - 0"4' - 0"8' - 0"BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT 7' - 0"3' - 0"10' - 0"PROJECT NO: DRAWN BY: CHECKED BY:6442 CITY WEST PARKWAYSUITE 300EDEN PRAIRIE, MINNESOTA 55344PH: 952-996-9662WWW.SRA-MN.COMCOPYRIGHT 2020SPERIDES REINERS ARCHITECTS, INCCPRELIMINARYNOT FOR CONSTRUCTIONSRaARCHITECTURE + INTERIORS8/1/2022 1:34:00 PM DK/BW DM 21-009 A302.1TCO LakevilleEXTERIOR ELEVATIONS 21219 KEOKUK AVENUE,LAKEVILLE, MN 55044SCALE:1/8" = 1'-0"A302.1 1 SOUTH ELEVATION - CITY SUBMITTAL SCALE:1/8" = 1'-0"A302.1 2 WEST ELEVATION - CITY SUBMITTAL SCALE:1/8" = 1'-0"A302.1 3 TRASH ENCLOSURE SOUTH ELEV SCALE:1/8" = 1'-0"A302.1 4 TRASH ENCLOSURE EAST ELEV SCALE:1/8" = 1'-0"A302.1 5 TRASH ENCLOSURE NORTH ELEV SCALE:1/8" = 1'-0"A302.1 6 TRASH ENCLOSURE WEST ELEV SCALE:1/8" = 1'-0"A302.1 7 MONUMENT SIGN ELEVATION ISSUE RECORDISSUE # DATE DESCRIPTION08/01/2022 CITY SUBMITTAL LEVEL 1 100' -0" LEVEL 2 115' -0" ROOF 130' -0" FIELDHOUSE ROOF 125' -0" PC-1PRECAST CONCRETE - BUFF -ACID ETCH PC-3PRECAST CONCRETE - BUFF -FORMLINER PC-2PRECAST CONCRETE - BUFF -SANDBLAST BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT BPC-2 PRECAST CONCRETE - THIN BRICK -IVORY BLEND ASF-1 ALUMINUM FRAMED STOREFRONT - THERMALLY BROKEN ACW-1GLAZED ALUMINUM CURTAIN WALL PFMF-2PRE-FINISHED METAL FLASHING -DARK GRAY PC-2PRECAST CONCRETE - BUFF -SANDBLAST ASF-1 ALUMINUM FRAMED STOREFRONT - THERMALLY BROKEN 65 SF SIGNAGE AREA MP-14" CORRUGATED T15 METAL WALL PANEL BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PC-3PRECAST CONCRETE - BUFF -FORMLINER PC-2PRECAST CONCRETE - BUFF -SANDBLAST PFMF-2PRE-FINISHED METAL FLASHING -DARK GRAY 24' - 9 1/2"33' - 0"2' - 0"13' - 0"14' - 0"4' - 0"33' - 0"35' - 0"LT-16" ROUND 2 DIRECTION WALL MOUNT LIGHT LEVEL 1 100' -0" LEVEL 2 115' -0" ROOF 130' -0" FIELDHOUSE ROOF 125' -0" ACW-1GLAZED ALUMINUM CURTAIN WALL BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT PC-3PRECAST CONCRETE - BUFF -FORMLINER PC-2PRECAST CONCRETE - BUFF -SANDBLAST PFMF-2PRE-FINISHED METAL FLASHING -DARK GRAY MP-14" CORRUGATED T15 METAL WALL PANEL MP-14" CORRUGATED T15 METAL WALL PANEL 135 SF SIGNAGE AREA 24' - 9 1/2"33' - 0"35' - 1 5/8"PC-1PRECAST CONCRETE - BUFF -ACID ETCH PC-3PRECAST CONCRETE - BUFF -FORMLINERPC-2PRECAST CONCRETE - BUFF -SANDBLAST MPC-1METAL PANEL - VANCOUVER COPPER MPC-2METAL PANEL -BLACK BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT BPC-2 PRECAST CONCRETE - THIN BRICK -IVORY BLEND MP-14" CORRUGATED T15 METAL WALL PANEL MATERIAL LEGEND EXTERIOR ELEVATION MATIERAL QUANTITIES EAST TOTAL SF: 5,635 SF BRICK: 2,120 SF 38% METAL PANEL: 362 SF 6% GLAZING: 1,791 SF 32% FORMLINER PRECAST: 397 SF 7% PRECAST (ACID ETCH/ SANDBLASTED): 965 SF 17% NORTH TOTAL SF: 5,257 SF BRICK:1,480 SF 28% METAL PANEL:1,641 SF 31% GLAZING:1,569 SF 30% FORMLINER PRECAST: 411 SF 8% PRECAST (ACID ETCH/ SANDBLASTED): 156 SF 3% SOUTH TOTAL SF: 5,048 SF BRICK:1,545 SF 31% METAL PANEL: 551 SF 11% GLAZING:1,741 SF 34% FORMLINER PRECAST: 259 SF 5% PRECAST (ACID ETCH/ SANDBLASTED): 9,88SF 19% WEST TOTAL SF: 5,501 SF BRICK:2,295 SF 42% METAL PANEL: 671 SF 12% GLAZING:1,628 SF 30% FORMLINER PRECAST: 452 SF 8% PRECAST (ACID ETCH/ SANDBLASTED): 455 SF 8% TOTAL PERIMETER SF: 21,477 SF BRICK:7,440 SF 35% METAL PANEL:3,225 SF 15% GLAZING:6,729 SF 31% FORMLINER PRECAST:1,519 SF 7% PRECAST (ACID ETCH/ SANDBLASTED):2,564 SF 12% LEVEL 1 100' -0"4 1/2"1' - 3"6"8"6"1' - 2"6"7 1/2" TYP.5' - 0"5' - 0" 1/2" TYP.5"1' - 2" 8" 2' - 0" 6" 2' - 0" 1' - 10" 1' - 0" 6" 1' - 6" 10" 6" 1' - 8" 1' - 4" 8" 1' - 8" 1' - 8" 8" 1' - 8" 6" 1' - 6" 10" 1' - 8" 1' - 6" 1' - 4" 1' - 10" 6" 1' - 8" 1' - 8" 6" 1' - 8" 1' - 4" 8" 1' - 0" 6" 1' - 6" 10" 6" 2' - 0" 1' - 10" 1' - 2" 8" 2' - 0" 8" 1' - 8" 6" 1' - 6" 10" 1' - 0" 1' - 6" PROJECT NO: DRAWN BY: CHECKED BY:6442 CITY WEST PARKWAYSUITE 300EDEN PRAIRIE, MINNESOTA 55344PH: 952-996-9662WWW.SRA-MN.COMCOPYRIGHT 2020SPERIDES REINERS ARCHITECTS, INCCPRELIMINARYNOT FOR CONSTRUCTIONSRaARCHITECTURE + INTERIORS8/1/2022 1:33:55 PM DK/BW DM 21-009 A301.1TCO LakevilleEXTERIOR ELEVATIONS 21219 KEOKUK AVENUE,LAKEVILLE, MN 55044SCALE:1/8" = 1'-0"A301.1 1 EAST ELEVATION - CITY SUBMITTAL SCALE:1/8" = 1'-0"A301.1 2 NORTH ELEVATION - CITY SUBMITTAL EXTERIOR MATERIAL SCHEDULE MATERIAL ID SPEC SECTION MATERIAL DESCRIPTION MANUFACTURER NOTES ACW-1 084413 GLAZED ALUMINUM CURTAIN WALL EFCO BLACK MULLIONS ASF-1 084313 ALUMINUM FRAMED STOREFRONT - THERMALLY BROKEN EFCO BLACK MULLIONS BPC-1 074213 PRECAST CONCRETE - THIN BRICK - DARK IRONSPOT ENDICOTT BPC-2 074213 PRECAST CONCRETE - THIN BRICK - IVORY BLEND ENDICOTT LT-1 034100 6" ROUND 2 DIRECTION WALL MOUNT LIGHT LITON LIGHTING MP-1 074213 4" CORRUGATED T15 METAL WALL PANEL FIRESTONE OMEGA VR CLASSIC - ANODIZED ALUMINUM MPC-1 074213 METAL PANEL - VANCOUVER COPPER REYNOBOND MPC-2 074213 METAL PANEL - BLACK REYNOBOND PC-1 034100 PRECAST CONCRETE - BUFF - ACID ETCH WELLS CONCRETE PC-2 034100 PRECAST CONCRETE - BUFF - SANDBLAST WELLS CONCRETE PC-3 034100 PRECAST CONCRETE - BUFF - FORMLINER RECKLI FORMLINERS PFMF-1 076200 PRE-FINISHED METAL FLASHING - VANCOUVER COPPER FIRESTONE TO MATCH MPC-1 PFMF-2 076200 PRE-FINISHED METAL FLASHING - DARK GRAY FIRESTONE TO MATCH MPC-2 PFMF-3 076200 PRE-FINISHED METAL FLASHING - SHERWIN W ILLIAMS NOMADIC DESERT 6107 FLUROPON TO MATCH PC-4 BPC-1 PRECAST CONCRETE - THIN BRICK -DARK IRONSPOT BPC-2 PRECAST CONCRETE - THIN BRICK -IVORY BLEND PC-2PRECAST CONCRETE - BUFF -SANDBLAST PC-1 PRECAST CONCRETE - BUFF -ACID ETCH MP-1 4" CORRUGATED T15 METAL WALL PANEL MPC-2 METAL PANEL -BLACK MPC-1 METAL PANEL - VANCOUVER COPPER PFMF-3 PRE-FINISHED METAL FLASHING -SHERWIN WILLIAMS NOMADIC DESERT 6107 PC-3PRECAST CONCRETE - BUFF -FORMLINER PFMF-1 PRE-FINISHED METAL FLASHING - VANCOUVER COPPER PC-2 PRECAST CONCRETE - BUFF -SANDBLAST PFMF-2 PRE-FINISHED METAL FLASHING -DARK GRAY 1/2" = 1'-0" FORMLINER TYPE ISSUE RECORDISSUE # DATE DESCRIPTION08/01/2022 CITY SUBMITTAL UP UP UP DN DN DN - - CANOPY TWO STORY MEDICAL OFFICE BUILDING 44,255 SF TOTAL 1A301.12 A301.1 1 A302.12A302.1- ELEVATORS VESTIBULE ELEVATORS TWO STORY MEDICAL OFFICE BUILDING 44,255 SF TOTAL OPEN TO BELOW 2 A301.1 1 A302.1 1A301.12A302.11A301.12 A301.1 1 A302.12A302.13A302.14 A302.1 5A302.16 A302.1 MECHANICAL SCREEN TRASH ENCLOSURE MONUMENT SIGN SEE CIVIL PLAN PREPARED BY LOUCKS 7A302.1CODE SUMMARY MINNESOTA STATE BUILDING CODE 2020, INCLUDING: - ELECTRICAL CODE - GAS CODE - MECHANICAL CODE - FIRE PREVENTION CODE (NFPA 101) - ENERGY CODE - ACCESSIBILITY CODE APPLICABLE CODES CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS PER SECTION 503 ALLOWABLE HEIGHT AND BUILDING AREAS: OCCUPANCY TYPE:B - BUSINESS CONSTRUCTION TYPE:II-B ALLOWABLE HEIGHT:4 STORIES = 75'-0" SPRINKLER SYSTEM:BUILDING IS FULLY SPRINKLERED AREA INCREASE FACTOR DUE TO FRONTAGE, SECTION 506.3.3:F = 474 FT, P = 651 FT; If = [(474/651) - 0.25] x 24.58/30 = 0.39 ALLOWABLE AREA, SECTION 506.2.1:Aa = 69,000 + (23,000 x 0.39) x 2 = 155,940 SF PROPOSED BUILDING AREA PER FLOOR: FIRST FLOOR 25,830 S.F. SECOND FLOOR 18,425 S.F. PROPOSED TOTAL BUILDING AREA: 44,255 S.F. PROPOSED BUILDING HEIGHT: 35 FEET TO TALLEST PARAPET (HIGHEST ROOF LINE OF SLOPED FLAT ROOF 32 FEET) BUILDING TO BE EQUIPPED THROUGHOUT WITH AUTOMATIC FIRE PROTECTION SYSTEM PER IBC 903.3.1.1 NFPA 13 CHAPTER 9: FIRE PROTECTION SYSTEMS PROJECT NO: DRAWN BY: CHECKED BY:6442 CITY WEST PARKWAYSUITE 300EDEN PRAIRIE, MINNESOTA 55344PH: 952-996-9662WWW.SRA-MN.COMCOPYRIGHT 2020SPERIDES REINERS ARCHITECTS, INCCPRELIMINARYNOT FOR CONSTRUCTIONSRaARCHITECTURE + INTERIORS8/1/2022 1:33:52 PM DK/BW DM 21-009 A200.1TCO LakevilleFLOOR PLANS 21219 KEOKUK AVENUE,LAKEVILLE, MN 55044SCALE:1/16" = 1'-0"A200.1 1 FIRST FLOOR PLAN - CITY SUBMITTAL SCALE:1/16" = 1'-0"A200.1 2 SECOND FLOOR PLAN - CITY SUBMITTAL SCALE:1" = 50'-0"A200.1 3 ARCHITECTURAL SITE PLAN - CITY SUBMITTAL N N N ISSUE RECORDISSUE # DATE DESCRIPTION08/01/2022 CITY SUBMITTAL Dakota County Surveyor’s Office Western Service Center  14955 Galaxie Avenue  Apple Valley, MN 55124 952.891 -7087  Fax 952.891 -7127  www.co.dakota.mn.us September 2, 2022 City of Lakeville 20195 Holyoke Ave. Lakeville, MN 55044 Re: KESWICK MEDICAL ADDITION The Dakota County Plat Commission met on August 31, 2022, to consider the preliminary plat of the above referenced plat. The plat is adjacent to CSAH 70 (210th St. W.) and is therefore subject to the Dakota County Contiguous Plat Ordinance. The proposed site includes a medical building with access along Keswick Road (a city street). The plat meets the future right-of-way needs of 75 feet of ½ right of way along CSAH 70. Restricted access should be shown along all of CSAH 70. A quit claim deed to Dakota County for restricted access is required with the recording of the plat mylars The Plat Commission has approved the preliminary and final plat, provided that the described conditions are met, and will recommend approval to the County Board of Commissioners on September 20, 2022. Traffic volumes on CSAH 70 are 6,700 ADT and are anticipated to be 8.200 ADT by the year 2040. No work shall commence in the County right of way until a permit is obtained from the County Transportation Department and no permit will be issued until the plat has been filed with the County Recorder’s Office. The Plat Commission does not review or approve the actual engineering design of proposed accesses or other improvements to be made in the right of way. Nothing herein is intended to restrict or limit Dakota County’s rights with regards to Dakota County rights of way or property. The Plat Commission highly recommends early contact with the Transportation Department to discuss the permitting process which reviews the design and may require construction of highway improvements, including, but not limited to, turn lanes, drainage features, limitations on intersecting street widths, medians, etc. Please contact Gordon McConnell regarding permitting questions at (952) 891-7115 or Todd Tollefson regarding Plat Commission or Plat Ordinance questions at (952) 891-7070. Sincerely, Todd B. Tollefson Secretary, Plat Commission c: City of Lakeville Public Works – Engineering Division Memorandum To: Frank Dempsey, Associate Planner From: Lucas Ritchie, Civil Engineer McKenzie L. Cafferty, Environmental Resources Manager John Hennen, Parks and Recreation Director Copy: Alex Jordan, Assistant City Engineer Zach Johnson, City Engineer Jerilyn Erickson, Finance Director Gene Abbott, Building Official Tina Goodroad, Community and Economic Development Director Date: October 12, 2022 Subject: Keswick Medical Addition • Preliminary and Final Plat Review • Site Plan Review • Grading and Erosion Control Plan Review • Utility Plan Review BBAACCKKGGRROOUUNNDD Frauenshuh Commercial Real Estate, on behalf of Hack Family, LLC and Twin City Orthopedics, has submitted a preliminary and final plat named Keswick Medical Addition and plans to construct a two-story, 44,255 square-foot, medical office facility. The proposed development is located south of and adjacent to 210th Street (CSAH 70), west of Interstate 35/CSAH 70 entrance/exist ramps, and north of and adjacent to Keswick Loop. The parent parcel consists of one meets and bounds parcel zoned C-3, General Commercial District (PID No. 220350001019). The preliminary and final plats consist of one lot within one block on 5.55 acres. The proposed development will be completed by: Developer: Frauenshuh Commercial Real Estate Engineer/Surveyor: Loucks Engineering/Land Surveying KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 22 OOFF 88 SSIITTEE CCOONNDDIITTIIOONNSS The existing site contains undeveloped agricultural land that slopes from the south to the north to a privately owned and maintained stormwater basin located on the north section of the property. EEAASSEEMMEENNTTSS The following easements will remain and will not be impacted by the site development: • 75-ft wide Northern Natural Gas Company Easement per Doc. No. 1296192 • Shared Drainage and Utility Easement per Doc. No. 3086869 SSTTRREEEETT AANNDD SSUUBBDDIIVVIISSIIOONN LLAAYYOOUUTT 210th Street (CSAH 70) Keswick Medical Addition is located south of and adjacent to 210th Street (CSAH 70), a minor arterial county roadway, as identified in the City’s Transportation Plan. 210th Street is constructed as a four-lane divided roadway with bituminous trails along both sides of the roadway within 160-feet of right-of-way. The Developer has incorporated the necessary right- of-way, as shown on the final plat. The preliminary plat was reviewed for approval by the Dakota County Plat Commission at its March 2, 2022 meeting. Keswick Loop Keswick Medical Addition is located north of and adjacent to Keswick Loop, a major collector roadway, as identified in the City’s Transportation Plan. Keswick Loop is constructed as a two- lane undivided rural roadway within 80-feet of right-of-way. No additional right-of-way will be required with the final plat for Keswick Loop. Access to the Keswick Medical Addition site is proposed from two driveway entrances on Keswick Loop. An existing driveway entrance on the west side of the property on Keswick Loop will be modified to serve the Keswick Medical Addition site along side the existing entrance to the Candlewood Suites site. SSIITTEE PPLLAANN Access to the site will be from two driveway entrances along Keswick Loop, located on the south plat boundary. The driveway designs shall include a stop sign and stop bar. The Developer shall provide an $10,000 security with the final plat for the construction of a commercial driveway apron and modifications to the existing driveway entrance on the south west plat boundary. An at-grade parking lot will be constructed to provide for employee and guest parking meeting the minimum parking requirements. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 33 OOFF 88 CCOONNSSTTRRUUCCTTIIOONN AACCCCEESSSS Construction traffic access and egress for grading, utility, building and parking lot construction shall be from a single rock construction entrance on Keswick Loop. PPAARRKKSS,, TTRRAAIILLSS AANNDD SSIIDD EEWWAALLKKSS The Park Dedication requirement for the parent parcel has not been paid and will be satisfied through a cash contribution with the final plat, calculated as follows: (5.55 acres - 0.47 acres) x $8,078.00 = $41,036.24 Area of Lot 1 , Block 1 Less the area of ROW dedication Commercial Park Dedication Rate Commercial Park Dedication The United Christian Academy development includes the construction of a pedestrian trail along the north side of Keswick Loop adjacent to the parcel parent, connecting to the existing trail system along CSAH 70. UUTTIILLIITTIIEESS SSAANN IITTAARRYY SSEE WWEERR Keswick Medical Addition is located within subdistrict SC-13420 of the South Creek sanitary sewer district as identified in the City’s Comprehensive Sewer Plan. Wastewater will be conveyed via existing trunk sanitary sewer to the MCES Elko/New Market Interceptor and continue to the Empire Wastewater Treatment Facility. The downstream facilities have sufficient capacity to serve the proposed commercial development. Development of United Christian Academy (UCA) to the south of the parent parcel includes the extension of public sanitary sewer to serve upstream properties within subdistrict SC- 13420. The Developer for Keswick Medical Addition shall dedicate the necessary permanent utility easements on the final plat and connect to the extension provided by the UCA development, consistent with the City’s Comprehensive Plan. Connection to the sanitary sewer shall not be permitted until the downstream utilities have been tested and accepted by the City. The Sanitary Sewer Availability Charge will be collected for the proposed building and will be required to be paid with the application for a building permit. WWAATTEERRMMAAIINN Development of United Christian Academy (UCA) to the south of the parent parcel includes the extension of public 8” watermain through the parent parcel to serve the Keswick Medical Addition. The Developer for Keswick Medical Addition shall dedicate the necessary permanent utility easements on the final plat and connect to the watermain provided by the UCA development, consistent with the City’s Comprehensive Plan. Connection to the watermain will not be permitted until the utility has been tested and accepted by the City. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 44 OOFF 88 The parent parcel is located within a “Future Boosted Pressure Zone” as identified in the City’s Water Plan. Due to the elevation of the site and no redundancy in the City’s service, water pressures for the site are below typical adequate domestic and fire suppression requirements. In order to provide adequate service, the City plans to extend watermain from the east, providing a redundant connection the City’s high pressure trunk watermain. Additionally, the City will construct a booster station to increase service pressures. The City’s water extension and booster station improvements are expected to be completed in 2023. Any improvements necessary to construct the proposed improvements with the existing service pressures will be required to be completed by the Developer. Final locations and sizes of all sanitary sewer and watermain facilities will be reviewed by City staff with the building permit application and final construction plans. OOVVEERRHHEEAADD LLIINN EESS There are no overhead utilities adjacent to the parent parcel. DDRRAAIINNAAGGEE AANNDD GGRRAADDIINNGG Keswick Medical Addition is located within subdistrict ML-082 of the Marion Lake stormwater district as identified in the City’s Water Resources Management Plan. Development of Keswick Medical Addition includes minor rate control modifications to the existing private detention basin and filtration basin. The private basins will be located on Lot 1, Block 1 and will continue to treat the Candlewood Suites site to the west of the parent parcel along with the Keswick Medical Addition site runoff. The Developer and Candlewood Suites property owner shall sign a private shared maintenance agreement for the stormwater basins and dedicate a maintenance easement over the basin areas prior to City Council consideration of the final plat. The stormwater management design is consistent with City requirements. The final grading plan shall identify all fill lots in which the building footings will be placed on fill material. The grading specifications shall also indicate that all embankments meet FHA/HUD 79G specifications. The Developer shall certify to the City that all lots with footings placed on fill material are appropriately constructed. Building Certificates of Occupancy will not be issued until a soils report and an as-built certified grading plan have been submitted and approved by City staff. Keswick Medical Addition contains more than one acre of site disturbance. A National Pollution Discharge Elimination System General Stormwater Permit for construction activity is required from the Minnesota Pollution Control Agency for areas exceeding one acre being disturbed by grading. A copy of the Notice of Stormwater Permit Coverage must be submitted to the City upon receipt from the MPCA. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 55 OOFF 88 SSTTOORRMM SSEEWWEERR Development of Keswick Medical Addition includes minor improvements to the privately owned and maintained storm sewer system. The Trunk Storm Sewer Area Charge has not been collected on the parent parcel and must be paid with the final plat, calculated as follows: (241,746 SF - 20,333 SF) x $0.25 / SF = $55,353.25 Area of Lot 1 , Block 1 Less the area of ROW dedication Commercial Area Charge Trunk Storm Sewer Area Charge Final locations and sizes of all storm sewer facilities will be reviewed by City staff with the building permit application and final construction plans. RREETTAAIINNIINNGG WWAALLLLSS Development of Keswick Medical Addition includes the construction of a privately owned and maintained retaining wall. The proposed retaining wall will be located north of the parking lot and building adjacent to the existing private stormwater basins. Retaining walls with a combined height greater than four feet shall be designed by a registered geotechnical or structural engineer and constructed in accordance with plans and specifications consistent with MnDOT requirements. A separate building permit from the City’s Building Official is required prior to the construction of the wall. The wall shall be inspected during construction and certified by the design engineer following construction. Additionally, an encroachment agreement is required with the final plat for the retaining wall proposed within drainage and utility easements prior to recording the final plat. The Developer shall post a $100,000 security with the final plat for the construction of the wall, which will be released when the wall is completed and certified by the design engineer following construction. FEMA FLOODPLAIN ANALYSIS Keswick Medical Addition is shown on the Flood Insurance Rate Map (FIRM) as Zone X, which is not designated as a Special Flood Hazard Area (SFHA) as determined by FEMA. WWEETTLLAANNDDSS The wetland delineation and replacement plan for the site was completed with the adjacent Candlewood Suites development to the west of the parent parcel. The wetland on the site was mitigated with the Candlewood Suites development. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 66 OOFF 88 TTRREEEE PPRREESSEERRVVAATTIIOONN The site was mass graded with development of the Candlewood Suites site. There are no significant trees on the parent parcel. EERROOSSIIOONN CCOONNTTRROOLL The plans include a detailed erosion and sediment control plan. The Developer is responsible for meeting all the requirements of the MPCA Construction Permit. Additional erosion control measures may be required during construction as deemed necessary by City staff. Any additional measures required shall be installed and maintained by the Developer. An on-site preconstruction meeting shall be held with the City prior to the issuance of a building permit. The MS4 Administration Fee has not been collected on the parent parcels and must be paid with the final plat. SECURITIES The Developer shall provide a Letter of Credit as security for the Developer-installed improvements relating to Keswick Medical Addition. CONSTRUCTION COSTS Retaining Wall $100,000.00 Driveway Entrances Erosion Control, Grading and Restoration 10,000.00 15,240.00 SUBTOTAL - CONSTRUCTION COSTS $ 125,240.00 OTHER COSTS Developer’s Design (3.0%) $ 3,757.20 Developer’s Construction Survey (2.5%) 3,131.00 City’s Legal Expense (0.5%) 626.20 City Construction Observation (5.0%) 6,262.00 Developer’s Record Drawing (0.5%) 626.60 Landscaping 30,000.00 Street Lights 2,800.00 Lot Corners/Iron Monuments 100.00 SUBTOTAL - OTHER COSTS $47,302.60 TOTAL PROJECT SECURITY $ 172,542.60 The street light security totals $2,800.00 which consists of two (2) mast-arm street light at $1,400 each. The Developer shall post a security to ensure the final placement of iron monuments at property corners with the final plat. The security is $100.00 per lot and outlot for a total of $100.00. The City shall hold this security until the Developer’s Land Surveyor certifies that all irons have been placed following site grading, street and utility construction. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 77 OOFF 88 CCAASSHH FFEEEESS A cash fee for one-year of streetlight operating expenses shall be paid at the time of final plat approval and is calculated as follows: 606.93 lf x $.2832/ff/qtr. x 4 qtrs. = $687.53 Lot 1, Block 1 Keswick Loop Frontage Streetlight Operating Fee Total A cash fee for one-year of environmental resources expenses shall be paid at the time of final plat approval and is calculated as follows: 5.08 acres x $71.52/acre/year x 4.2 = $1,525.95 Lot 1, Block 1 Area Environmental Resources Fee Utility Factor Total A cash fee for the preparation of record construction drawings and for upgrading the City base map shall be paid at the time of final plat approval and is calculated as follows: 1 units x $90.00/unit = $90.00 Lots/Outlots City Base Map Updating Fee Total The Developer shall submit the final plat and construction drawings in an electronic format. The electronic format shall be in either .dwg (AutoCAD) or .dxf format. The Developer shall also pay a cash fee for City Engineering Administration. The fee for City Engineering Administration will be based on three percent (3.00%) of the estimated construction cost, or $3,757.20. CASH REQUIREMENTS Park Dedication Fee Trunk Storm Sewer Area Charge Lateral Sanitary Sewer Access Charge Lateral Watermain Access Charge MS4 Admin Fee $41,036.24 55,353.25 15,355.83 17,760.96 304.80 Streetlight Operating Fee 687.53 Environmental Resources Fee 1,525.95 City Base Map Updating Fee 90.00 City Engineering Administration (3.00%) 3,757.20 SUBTOTAL - CASH REQUIREMENTS $135,871.76 TOTAL - CASH REQUIREMENTS $135,871.76 KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 88 OOFF 88 RREECCOOMMMMEENNDDAATTIIOONN Engineering recommends approval of the preliminary and final plat, site plan, grading and erosion control plan, and utility plan for Keswick Medical Addition, subject to the requirements and stipulations within this report. City of Lakeville Public Works – Engineering Division Memorandum To: Frank Dempsey, Associate Planner From: Lucas Ritchie, Civil Engineer McKenzie L. Cafferty, Environmental Resources Manager John Hennen, Parks and Recreation Director Copy: Alex Jordan, Assistant City Engineer Zach Johnson, City Engineer Jerilyn Erickson, Finance Director Gene Abbott, Building Official Tina Goodroad, Community and Economic Development Director Date: October 12, 2022 Subject: Keswick Medical Addition • Preliminary and Final Plat Review • Site Plan Review • Grading and Erosion Control Plan Review • Utility Plan Review BBAACCKKGGRROOUUNNDD Frauenshuh Commercial Real Estate, on behalf of Hack Family, LLC and Twin City Orthopedics, has submitted a preliminary and final plat named Keswick Medical Addition and plans to construct a two-story, 44,255 square-foot, medical office facility. The proposed development is located south of and adjacent to 210th Street (CSAH 70), west of Interstate 35/CSAH 70 entrance/exist ramps, and north of and adjacent to Keswick Loop. The parent parcel consists of one meets and bounds parcel zoned C-3, General Commercial District (PID No. 220350001019). The preliminary and final plats consist of one lot within one block on 5.55 acres. The proposed development will be completed by: Developer: Frauenshuh Commercial Real Estate Engineer/Surveyor: Loucks Engineering/Land Surveying KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 22 OOFF 88 SSIITTEE CCOONNDDIITTIIOONNSS The existing site contains undeveloped agricultural land that slopes from the south to the north to a privately owned and maintained stormwater basin located on the north section of the property. EEAASSEEMMEENNTTSS The following easements will remain and will not be impacted by the site development: • 75-ft wide Northern Natural Gas Company Easement per Doc. No. 1296192 • Shared Drainage and Utility Easement per Doc. No. 3086869 SSTTRREEEETT AANNDD SSUUBBDDIIVVIISSIIOONN LLAAYYOOUUTT 210th Street (CSAH 70) Keswick Medical Addition is located south of and adjacent to 210th Street (CSAH 70), a minor arterial county roadway, as identified in the City’s Transportation Plan. 210th Street is constructed as a four-lane divided roadway with bituminous trails along both sides of the roadway within 160-feet of right-of-way. The Developer has incorporated the necessary right- of-way, as shown on the final plat. The preliminary plat was reviewed for approval by the Dakota County Plat Commission at its March 2, 2022 meeting. Keswick Loop Keswick Medical Addition is located north of and adjacent to Keswick Loop, a major collector roadway, as identified in the City’s Transportation Plan. Keswick Loop is constructed as a two- lane undivided rural roadway within 80-feet of right-of-way. No additional right-of-way will be required with the final plat for Keswick Loop. Access to the Keswick Medical Addition site is proposed from two driveway entrances on Keswick Loop. An existing driveway entrance on the west side of the property on Keswick Loop will be modified to serve the Keswick Medical Addition site along side the existing entrance to the Candlewood Suites site. SSIITTEE PPLLAANN Access to the site will be from two driveway entrances along Keswick Loop, located on the south plat boundary. The driveway designs shall include a stop sign and stop bar. The Developer shall provide an $10,000 security with the final plat for the construction of a commercial driveway apron and modifications to the existing driveway entrance on the south west plat boundary. An at-grade parking lot will be constructed to provide for employee and guest parking meeting the minimum parking requirements. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 33 OOFF 88 CCOONNSSTTRRUUCCTTIIOONN AACCCCEESSSS Construction traffic access and egress for grading, utility, building and parking lot construction shall be from a single rock construction entrance on Keswick Loop. PPAARRKKSS,, TTRRAAIILLSS AANNDD SSIIDD EEWWAALLKKSS The Park Dedication requirement for the parent parcel has not been paid and will be satisfied through a cash contribution with the final plat, calculated as follows: (5.55 acres - 0.47 acres) x $8,078.00 = $41,036.24 Area of Lot 1 , Block 1 Less the area of ROW dedication Commercial Park Dedication Rate Commercial Park Dedication The United Christian Academy development includes the construction of a pedestrian trail along the north side of Keswick Loop adjacent to the parcel parent, connecting to the existing trail system along CSAH 70. UUTTIILLIITTIIEESS SSAANN IITTAARRYY SSEE WWEERR Keswick Medical Addition is located within subdistrict SC-13420 of the South Creek sanitary sewer district as identified in the City’s Comprehensive Sewer Plan. Wastewater will be conveyed via existing trunk sanitary sewer to the MCES Elko/New Market Interceptor and continue to the Empire Wastewater Treatment Facility. The downstream facilities have sufficient capacity to serve the proposed commercial development. Development of United Christian Academy (UCA) to the south of the parent parcel includes the extension of public sanitary sewer to serve upstream properties within subdistrict SC- 13420. The Developer for Keswick Medical Addition shall dedicate the necessary permanent utility easements on the final plat and connect to the extension provided by the UCA development, consistent with the City’s Comprehensive Plan. Connection to the sanitary sewer shall not be permitted until the downstream utilities have been tested and accepted by the City. The Sanitary Sewer Availability Charge will be collected for the proposed building and will be required to be paid with the application for a building permit. WWAATTEERRMMAAIINN Development of United Christian Academy (UCA) to the south of the parent parcel includes the extension of public 8” watermain through the parent parcel to serve the Keswick Medical Addition. The Developer for Keswick Medical Addition shall dedicate the necessary permanent utility easements on the final plat and connect to the watermain provided by the UCA development, consistent with the City’s Comprehensive Plan. Connection to the watermain will not be permitted until the utility has been tested and accepted by the City. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 44 OOFF 88 The parent parcel is located within a “Future Boosted Pressure Zone” as identified in the City’s Water Plan. Due to the elevation of the site and no redundancy in the City’s service, water pressures for the site are below typical adequate domestic and fire suppression requirements. In order to provide adequate service, the City plans to extend watermain from the east, providing a redundant connection the City’s high pressure trunk watermain. Additionally, the City will construct a booster station to increase service pressures. The City’s water extension and booster station improvements are expected to be completed in 2023. Any improvements necessary to construct the proposed improvements with the existing service pressures will be required to be completed by the Developer. Final locations and sizes of all sanitary sewer and watermain facilities will be reviewed by City staff with the building permit application and final construction plans. OOVVEERRHHEEAADD LLIINN EESS There are no overhead utilities adjacent to the parent parcel. DDRRAAIINNAAGGEE AANNDD GGRRAADDIINNGG Keswick Medical Addition is located within subdistrict ML-082 of the Marion Lake stormwater district as identified in the City’s Water Resources Management Plan. Development of Keswick Medical Addition includes minor rate control modifications to the existing private detention basin and filtration basin. The private basins will be located on Lot 1, Block 1 and will continue to treat the Candlewood Suites site to the west of the parent parcel along with the Keswick Medical Addition site runoff. The Developer and Candlewood Suites property owner shall sign a private shared maintenance agreement for the stormwater basins and dedicate a maintenance easement over the basin areas prior to City Council consideration of the final plat. The stormwater management design is consistent with City requirements. The final grading plan shall identify all fill lots in which the building footings will be placed on fill material. The grading specifications shall also indicate that all embankments meet FHA/HUD 79G specifications. The Developer shall certify to the City that all lots with footings placed on fill material are appropriately constructed. Building Certificates of Occupancy will not be issued until a soils report and an as-built certified grading plan have been submitted and approved by City staff. Keswick Medical Addition contains more than one acre of site disturbance. A National Pollution Discharge Elimination System General Stormwater Permit for construction activity is required from the Minnesota Pollution Control Agency for areas exceeding one acre being disturbed by grading. A copy of the Notice of Stormwater Permit Coverage must be submitted to the City upon receipt from the MPCA. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 55 OOFF 88 SSTTOORRMM SSEEWWEERR Development of Keswick Medical Addition includes minor improvements to the privately owned and maintained storm sewer system. The Trunk Storm Sewer Area Charge has not been collected on the parent parcel and must be paid with the final plat, calculated as follows: (241,746 SF - 20,333 SF) x $0.25 / SF = $55,353.25 Area of Lot 1 , Block 1 Less the area of ROW dedication Commercial Area Charge Trunk Storm Sewer Area Charge Final locations and sizes of all storm sewer facilities will be reviewed by City staff with the building permit application and final construction plans. RREETTAAIINNIINNGG WWAALLLLSS Development of Keswick Medical Addition includes the construction of a privately owned and maintained retaining wall. The proposed retaining wall will be located north of the parking lot and building adjacent to the existing private stormwater basins. Retaining walls with a combined height greater than four feet shall be designed by a registered geotechnical or structural engineer and constructed in accordance with plans and specifications consistent with MnDOT requirements. A separate building permit from the City’s Building Official is required prior to the construction of the wall. The wall shall be inspected during construction and certified by the design engineer following construction. Additionally, an encroachment agreement is required with the final plat for the retaining wall proposed within drainage and utility easements prior to recording the final plat. The Developer shall post a $100,000 security with the final plat for the construction of the wall, which will be released when the wall is completed and certified by the design engineer following construction. FEMA FLOODPLAIN ANALYSIS Keswick Medical Addition is shown on the Flood Insurance Rate Map (FIRM) as Zone X, which is not designated as a Special Flood Hazard Area (SFHA) as determined by FEMA. WWEETTLLAANNDDSS The wetland delineation and replacement plan for the site was completed with the adjacent Candlewood Suites development to the west of the parent parcel. The wetland on the site was mitigated with the Candlewood Suites development. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 66 OOFF 88 TTRREEEE PPRREESSEERRVVAATTIIOONN The site was mass graded with development of the Candlewood Suites site. There are no significant trees on the parent parcel. EERROOSSIIOONN CCOONNTTRROOLL The plans include a detailed erosion and sediment control plan. The Developer is responsible for meeting all the requirements of the MPCA Construction Permit. Additional erosion control measures may be required during construction as deemed necessary by City staff. Any additional measures required shall be installed and maintained by the Developer. An on-site preconstruction meeting shall be held with the City prior to the issuance of a building permit. The MS4 Administration Fee has not been collected on the parent parcels and must be paid with the final plat. SECURITIES The Developer shall provide a Letter of Credit as security for the Developer-installed improvements relating to Keswick Medical Addition. CONSTRUCTION COSTS Retaining Wall $100,000.00 Driveway Entrances Erosion Control, Grading and Restoration 10,000.00 15,240.00 SUBTOTAL - CONSTRUCTION COSTS $ 125,240.00 OTHER COSTS Developer’s Design (3.0%) $ 3,757.20 Developer’s Construction Survey (2.5%) 3,131.00 City’s Legal Expense (0.5%) 626.20 City Construction Observation (5.0%) 6,262.00 Developer’s Record Drawing (0.5%) 626.60 Landscaping 30,000.00 Street Lights 2,800.00 Lot Corners/Iron Monuments 100.00 SUBTOTAL - OTHER COSTS $47,302.60 TOTAL PROJECT SECURITY $ 172,542.60 The street light security totals $2,800.00 which consists of two (2) mast-arm street light at $1,400 each. The Developer shall post a security to ensure the final placement of iron monuments at property corners with the final plat. The security is $100.00 per lot and outlot for a total of $100.00. The City shall hold this security until the Developer’s Land Surveyor certifies that all irons have been placed following site grading, street and utility construction. KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 77 OOFF 88 CCAASSHH FFEEEESS A cash fee for one-year of streetlight operating expenses shall be paid at the time of final plat approval and is calculated as follows: 606.93 lf x $.2832/ff/qtr. x 4 qtrs. = $687.53 Lot 1, Block 1 Keswick Loop Frontage Streetlight Operating Fee Total A cash fee for one-year of environmental resources expenses shall be paid at the time of final plat approval and is calculated as follows: 5.08 acres x $71.52/acre/year x 4.2 = $1,525.95 Lot 1, Block 1 Area Environmental Resources Fee Utility Factor Total A cash fee for the preparation of record construction drawings and for upgrading the City base map shall be paid at the time of final plat approval and is calculated as follows: 1 units x $90.00/unit = $90.00 Lots/Outlots City Base Map Updating Fee Total The Developer shall submit the final plat and construction drawings in an electronic format. The electronic format shall be in either .dwg (AutoCAD) or .dxf format. The Developer shall also pay a cash fee for City Engineering Administration. The fee for City Engineering Administration will be based on three percent (3.00%) of the estimated construction cost, or $3,757.20. CASH REQUIREMENTS Park Dedication Fee Trunk Storm Sewer Area Charge Lateral Sanitary Sewer Access Charge Lateral Watermain Access Charge MS4 Admin Fee $41,036.24 55,353.25 15,355.83 17,760.96 304.80 Streetlight Operating Fee 687.53 Environmental Resources Fee 1,525.95 City Base Map Updating Fee 90.00 City Engineering Administration (3.00%) 3,757.20 SUBTOTAL - CASH REQUIREMENTS $135,871.76 TOTAL - CASH REQUIREMENTS $135,871.76 KKEESSWWIICCKK MMEEDDIICCAALL AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT OOCCTTOOBBEERR 1122,, 22002222 PPAAGGEE 88 OOFF 88 RREECCOOMMMMEENNDDAATTIIOONN Engineering recommends approval of the preliminary and final plat, site plan, grading and erosion control plan, and utility plan for Keswick Medical Addition, subject to the requirements and stipulations within this report.