HomeMy WebLinkAboutLA207572 - APPROVED - PenroseStampedPlans1.1.1PROJECT NOTES:1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONALELECTRIC CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING ANDINSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BYTHE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES.1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PVSYSTEM INSPECTED PRIOR TO PARALLEL OPERATION1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATEDWITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B)1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USEIN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMPCOEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATEDACCORDING TO NEC 690.7.1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, ANDSOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAICPOWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROMLISTING OR LABELING [NEC 110.3].1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IFEXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES ANDSIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.1.2.1 SCOPE OF WORK:1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONSOF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTORWILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TODESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OFTHE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT.1.3.1 WORK INCLUDES:1.3.2 PV ROOF ATTACHMENTS - IRONRIDGE FLASHFOOT21.3.3 PV RACKING SYSTEM INSTALLATION - IRONRIDGE XR-1001.3.4 PV MODULE AND INVERTER INSTALLATION - LG ELECTRONICS LG370N1K-E6 /ENPHASE IQ8PLUS-72-2-US1.3.5 PV EQUIPMENT GROUNDING1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX1.3.7 PV LOAD CENTERS (IF INCLUDED)1.3.8 PV METERING/MONITORING (IF INCLUDED)1.3.9 PV DISCONNECTS1.3.10 PV GROUNDING ELECTRODE & BONDING TO (E) GEC1.3.11 PV FINAL COMMISSIONING1.3.12 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODEGENERAL NOTESN2017MSCOPE OF WORKSYSTEM SIZE: STC: 33 X 370W = 12.210KWPTC: 33 X 344.1W = 11.355KW(33) LG ELECTRONICS LG370N1K-E6(33) ENPHASE IQ8PLUS-72-2-USATTACHMENT TYPE: IRONRIDGE FLASHFOOT2MSP UPGRADE: NOOWNERNAME: RACHEL PENROSEPROJECT MANAGERNAME: KEVIN VICKERSPHONE: 763-412-5714CONTRACTORNAME: GOLDEN ELECTRIC LLCPHONE: 763-412-5714AUTHORITIES HAVING JURISDICTIONBUILDING: CITY OF LAKEVILLEZONING: CITY OF LAKEVILLEUTILITY: DAKOTA ELECTRICDESIGN SPECIFICATIONSOCCUPANCY: IICONSTRUCTION: SINGLE-FAMILYZONING: RESIDENTIALGROUND SNOW LOAD: 50 PSFWIND EXPOSURE: ВWIND SPEED: 115 MPHAPPLICABLE CODES & STANDARDSBUILDING: MSBC 2020, MSRC 2020ELECTRICAL: NEC 2017FIRE: MSFC 2020PROJECT INFORMATIONNEW PV SYSTEM:DС 12.210 KWP / AC 9.570 KWPPENROSE RESIDENCE19301 IMPALA AVELAKEVILLE, MN 55044ASSESSOR'S #: 227335301110BFAD E23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:AC D EG HB CF G H1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCET-001.00COVER PAGE(SHEET 1)01AERIAL PHOTONOT TO SCALENEWS02PLAT MAPNOT TO SCALEIMPALA AVESHEET LIST TABLESHEET NUMBER SHEET TITLET-001COVER PAGEG-001 NOTESA-101SITE PLANA-102ELECTRICAL PLANA-103SOLAR ATTACHMENT PLANE-601LINE DIAGRAME-602DESIGN TABLESE-603PLACARDSS-501 ASSEMBLY DETAILSR-001 RESOURCE DOCUMENTR-002 RESOURCE DOCUMENTR-003 RESOURCE DOCUMENTR-004 RESOURCE DOCUMENTR-005 RESOURCE DOCUMENTR-006 RESOURCE DOCUMENT10.18.22 2.1.1SITE NOTES:2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM ISA UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL, OR BUILDING ROOF VENTS.2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTIONNEC 110.26.2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.2.2.1EQUIPMENT LOCATIONS:2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BYNEC 110.26.2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOREXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C)AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTERIS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNELACCORDING TO NEC APPLICABLE CODES.2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOROUTDOOR USAGE WHEN APPROPRIATE.2.3.1STRUCTURAL NOTES:2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE ADESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND AMINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS.2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS.IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED ANDSEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSEDCONTRACTOR.2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.2.4.1WIRING & CONDUIT NOTES:2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.2.4.4 VOLTAGE DROP LIMITED TO 1.5%.2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLEWIRING CLIPS.2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GRAYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGETO BE MARKED ORANGE [NEC 110.15].2.5.1GROUNDING NOTES:2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FORSUCH USE.2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 ANDMINIMUM NEC TABLE 250.122.2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURESCONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC690.45 AND MICROINVERTER MANUFACTURERS' INSTRUCTIONS.2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS ASSHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IFWEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED ATTHE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS.2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCHTHAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDINGCONDUCTOR TO ANOTHER MODULE.2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOREDGREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, ORINADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TONEC 250, NEC 690.47 AND AHJ.2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TOREDUCE FIRE HAZARDS2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCHIS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TOTHE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE ARAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCYRESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D).2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9,AND 240.2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER ORGROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B).2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTIONACCORDING TO NEC 690.11 AND UL1699B.2.7.1INTERCONNECTION NOTES:2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC705.12 (B)]2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAYNOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)].2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUITCURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITEEND OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)].2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTALRATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BEEXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C).2.7.6 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12(B)(2)(1)2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITHSERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.422.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPTFROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)].N2017M N2017M BFAD E23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:AC D EG HB CF G H1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCEG-001.00NOTES(SHEET 2)10.18.22 GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGEA-101.00SITE PLAN(SHEET 3)ENTRANCEBFAD E23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:AC D EG HB CF G H1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCE01/16" = 1'-0"SITE PLAN018' 16'NEWSNEWSIMPALA AVE AREA OF WORKPROPERTY LINEAC COMBINER BOXPV METERUTILITY AC DISCONNECTUTILITY METER12'-8"61'-3"19'-3"66'-11"10.18.22 GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGEMODULE:LG ELECTRONICSLG370N1K-E6370 WATTS41''69.6''BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCEA-102.00ELECTRICAL PLAN(SHEET 4)01/8" = 1'-0"ELECTRICAL PLAN014' 8'NEWSAMODULE STRINGINGBMODULE STRINGINGCMODULE STRINGINGFIRE CLEARANCE(N) (1) JUNCTION BOXARRAY 1 - 12.210 kW[x33] (N) MODULESTILT: 25 DEGREESROOF PITCH: 5:12AZIMUTH: 270 DEGREES(N) (1) AC COMBINER BOX(N) (1) PV METER(N) (1) UTILITY AC DISCONNECTEXTERIOR PV EQUIPMENTINTERIOR PV EQUIPMENT(E) (1) MAIN ELECTRICAL PANEL(E) (1) UTILITY METER18 IN. FIRE ACCESS PATH18 IN. FIRE ACCESS PATH3 FT. FIRE ACCESS PATHABCABCABCABCABCABCABCABCABCABCABCConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode10/19/2022dpfannensteinNo less than 18 inch clearsetback is required on bothsides of a horizontal ridge,valley, or hipFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side. GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGEMODULE:LG ELECTRONICSLG370N1K-E6370 WATTS41''69.6''BFAD E23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:AC D EG HB CF G H1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCEA-103.00SOLAR ATTACHMENT PLAN(SHEET 5)01/8" = 1'-0"SOLAR ATTACHMENT PLAN014' 8'NEWSROOF TRUSSESFLUSH MOUNT SOLAR MODULESATTACHED TO ROOF SURFACE (SEESHEET S-501 FOR MOUNTING DETAILS)ROOF MATERIAL IS ASPHALT SHINGLE37'-10"10.18.22 125A AC COMBINER BOX 4(X-IQ-AM1-240-4)120/240V, 1Ø, 3WMAX. CONTINUOUS CURRENT: 65AMAX. OCPD: 90AL1NL2ENPHASE ENVOYCOMMUNICATIONSGATEWAYGCB120A24TO UTILITYGRID (UG)L1L2N(E) GROUNDINGELECTRODEGROUNDRODNG(E)UTILITYMETERTO (E)LOADSL2L1(E)MAIN200AEQUIPMENT LEFTOF LINE IS (N) NEWUNLESS OTHERWISE NOTED.EQUIPMENT RIGHTOF LINE IS (E) EXISTINGUNLESS OTHERWISE NOTED.TAP(N) (33) ENPHASEIQ8PLUS-72-2-US240V, 1 PHASE, 3WRATED POWER: 290W(N) (33) LG ELECTRONICSLG370N1K-E6370 WATTS(N) JUNCTIONBOXCB220ACB320ACB410AIN BRANCHC11IN BRANCHB11IN BRANCHА11GSW1F1-2BLACKREDGBLACKREDBLACKRED11. PV SYSTEM EQUIPPED WITH RAPIDSHUTDOWN DISCONNECT PER NEC 690.122. SYSTEM COMPLIANT WITH NEC 690.13(Е) MAIN ELECTRICAL PANEL240/120 V 1Ø, 3WMAIN BUSS: 200A(N) AC DISCONNECT, 60 AWITH FUSES 50A(N) PV METERMILBANK 200 AMP WITHLEVER BY PASS31. DOUBLE-LUGS REQUIRED ON LINE SIDE OF EXISTING HOUSE METER.2. FUSED АС DISCONNECT SHOULD ВЕ INSTALLED IN ТНЕ OFF POSITION.3. CONTACT ERMU ТО SCHEDULE DISCONNECТ OF POWER АТ HOUSE METERWHEN READY ТО МАКЕ CONNECTIONS.4. ALL WIRING MUST МЕЕТ NEC REQUIREMENTS AND ВЕ INSPECTED PRIORТО INSTALLING ERMU PRODUCTION METER.NV TOP LUGSBOTTOM LUGSM1CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONSID TYPICALCONDUCTORCONDUITCURRENT-CARRYINGCONDUCTORS IN CONDUITOCPDEGCTEMP. CORR.FACTORCONDUIT FILLFACTORCONT.CURRENTMAX. CURRENT(125%)BASE AMP.DERATEDAMP.TERM. TEMP. RATINGAMP. @ TERMINAL1110 AWG THWN-2, COPPER0.75'' DIA EMT620A6 AWG THWN-2, COPPER0.96 (32.1 °C)0.813.31A 16.64A40A 30.72A75°C35A218 AWG THWN-2, COPPER0.75'' DIA EMT250A6 AWG THWN-2, COPPER0.96 (32.1 °C)139.93A 49.91A55A52.8A75°C50A318 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.1 °C)139.93A 49.91A55A52.8A75°C50A416 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.1 °C)139.93A 49.91A75A72A75°C65AMODULE STRINGINGCMODULE STRINGINGBMODULE STRINGINGAE-601.00LINE DIAGRAM(SHEET 6)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCE SYSTEM SUMMARYBRANCH #1BRANCH #2BRANCH #3INVERTERS PER BRANCH111111MAX AC CURRENT13.31A13.31A13.31AMAX AC OUTPUT POWER3,300W3,300W3,300WARRAY STC POWER12,210WARRAY PTC POWER11,355WMAX AC CURRENT39.93AMAX AC POWER9,570WDERATED (CEC) AC POWER9,570WDISCONNECTSINVERTERSOCPDSMODULESASHRAE EXTREME LOW-35.2°C (-31.4°F), SOURCE: AIRLAKE (44.63°; -93.22°)ASHRAE 2% HIGH32.1°C (89.8°F), SOURCE: AIRLAKE (44.63°; -93.22°)REF.QTY.RATED CURRENTMAX VOLTAGECB1-3320A240VACCB4 110A240VACF1-2 250A240VACREF.QTY.MAKE AND MODELRATED CURRENT MAX RATED VOLTAGESW1 1EATON DG222NRB OR EQUIV.60A240VACREF.QTY.MAKE AND MODELPMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATINGPM1-33 33LG ELECTRONICS LG370N1K-E6370W 344.1W 11.23A 10.68A41.4V34.7V-0.108V/°C (-0.26%/°C)20AREF.QTY.MAKE AND MODELACVOLTAGEGROUNDOCPDRATINGRATEDPOWERMAX OUTPUTCURRENTMAX INPUTCURRENTMAX INPUTVOLTAGECEC WEIGHTEDEFFICIENCYI1-33 33ENPHASE IQ8PLUS-72-2-US240VFLOATING20A 290W1.21A15A 60V97.0%BILL OF MATERIALSCATEGORYMAKEMODEL NUMBERREFQTYUNITQTY/UNITDESCRIPTIONMODULELG ELECTRONICSLG370N1K-E6PM1-33 33PIECES 1LG ELECTRONICS LG370N1K-E6 370W 120 HALF-CUT CELLS, MONOCRYSTALLINE SILICONINVERTERENPHASEIQ8PLUS-72-2-USI1-3333PIECES 1ENPHASE IQ8PLUS-72-2-US 290W INVERTERDISCONNECTEATONDG222NRBSW11 PIECE 1EATON DG222NRB, FUSED, 2-POLE, 60A, 240VAC OR EQUIVALENTPRODUCTION METERGENERIC MANUFACTURERGEN-METER-200AM11 PIECE 1ELECTRICAL METER, OWNER APPROVEDMISC ELECTRICAL EQUIPMENTGEN-CABLE-CLIPHDWR36-201 165 PIECES1GENERIC CABLE CLIPAC COMBINER PANELENPHASE-IQ4-PANELEP11 PIECE 1ENPHASE IQ COMBINER 4 (X-IQ-AM1-240-4)WIRINGENPHASEQ-12-17-240EN1-33 33PIECES 1ENPHASE ENGAGE (TM) TRUNK CABLEWIRINGENPHASEQ-TERM-10EN341BUNDLE10ENPHASE ENGAGE (TM) BRANCH TERMINATORWIRINGENPHASEQ-SEAL-10EN351BUNDLE 10ENPHASE ENGAGE (TM) WATERTIGHT SEALING CAPWIRINGGEN-10-AWG-THWN-2-CU-RDWR1135FEET 110 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-10-AWG-THWN-2-CU-BLKWR1135FEET 110 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-8-AWG-THWN-2-CU-RDWR2-3 20FEET 18 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-8-AWG-THWN-2-CU-BLKWR2-3 20 FEET18 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-8-AWG-THWN-2-CU-WHWR2-3 20FEET 18 AWG THWN-2, COPPER, WHITE (NEUTRAL)WIRINGGEN-6-AWG-THWN-2-CU-RDWR410FEET 16 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-6-AWG-THWN-2-CU-BLKWR410 FEET 16 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-6-AWG-THWN-2-CU-WHWR410FEET 16 AWG THWN-2, COPPER, WHITE (NEUTRAL)WIRINGGEN-6-AWG-THWN-2-CU-GRWR1-475 FEET16 AWG THWN-2, COPPER, GREEN (GROUND)WIREWAYENPHASEET-SPLK-05EN61BUNDLE 5ENPHASE ENGAGE (TM) ENGAGE COUPLERWIREWAYGEN-EMT-0.75'' DIAWW1-475FEET 1EMT CONDUIT, 0.75'' DIAOCPDGENERIC MANUFACTURERGEN-CB-20A-240VACCB1-33 PIECES 1CIRCUIT BREAKER, 20A, 240VACOCPDGENERIC MANUFACTURERGEN-CB-10A-240VACCB41 PIECE 1CIRCUIT BREAKER, 10A, 240VACOCPDGENERIC MANUFACTURERGEN-FU-50A-240VACF1-22 PIECES 1FUSE, 50A, 240VACTRANSITION BOXGENERIC MANUFACTURERGEN-AWB-TB-4-4XJB11 PIECE 1TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKSE-602.00DESIGN TABLES(SHEET 7)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCE (N) AC COMBINER BOXTO PV ARRAY(E) UTILITY(E) UTILITY METERNOT TO EXCEED 6'-7" FROM GRADE GRADE(N) UTILITY ACDISCONNECTTO (E) MEP(INSIDE)(N) PV METERNEWSE-603.00PLACARDS(SHEET 8)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCEEQUIPMENT ELEVATION01SCALE: NOT TO SCALE!CAUTION!POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM ROOF MOUNTED SOLAR ARRAYS WITHSAFETY DISCONNECTS AS SHOWN:LABELING NOTES1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z5351.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVINGJURISDICTION.1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENTINVOLVED.1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED.1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE REDBACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVEYELLOW BACKGROUND. [ANSI Z535]ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL 1AT EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT (2" X 4").[NEC 690.13].POWER SOURCEOUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNINGLABEL 2AT POINT OF INTERCONNECTIONOVERCURRENT DEVICE (2" X 4").[NEC 705.12(B)(2)(3)(B)].PHOTOVOLTAIC SYSTEMAC DISCONNECTRATED AC OUTPUT CURRENTNOMINAL OPERATING AC VOLTAGELABEL 3AT POINT OF INTERCONNECTION, MARKEDAT DISCONNECTING MEANS (4" X 2").[NEC 690.54]LABEL 4AT EACH AC DISCONNECTING MEANS(4" X 1").[NEC 690.13(B)].INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTEDPHOTOVOLTAIC SYSTEM DISCONNECT LOCATEDSOUTH SIDE OF THE HOUSEDIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICEDISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTINGMEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8").[NEC 690.56(B)]WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, ADIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PVSYSTEM DISCONNECTING MEANS.PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED INBATHROOMS[NEC 690.4(D),(E)]WARNING: PHOTOVOLTAICPOWER SOURCELABEL 9AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRINGMETHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERESEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS,OR FLOORS (5 3/4" X 1 1/8").[NEC 690.31(G)]LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND;REFLECTIVE[IFC 605.11.1.1]SOLAR PV SYSTEMEQUIPPED WITHRAPID SHUTDOWNTURN RAPID SHUTDOWN SWITCH TOTHE "OFF" POSITION TO SHUT DOWNPV SYSTEM AND REDUCE SHOCKHAZARD IN ARRAYSOLAR ELECTRICPV PANELSLABEL 6AT RAPID SHUTDOWN SYSTEM(3 3/4" X 5 1/4"). [NEC 690.56(C)(1)(A)].WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLARELECTRIC SYSTEMLABEL 7AT POINT OF INTERCONNECTION(2 3/4" X 1 5/8").[NEC 705.12(B)(3)]WARNINGSOLAR ELECTRICCIRCUIT BREAKERIS BACKFEEDPHOTOVOLTAIC SOLARAC DISCONNECTLABEL 8AT POINT OF INTERCONNECTION(2" X 1").[NEC 705.12(B)(3)]CAUTIONSOLAR ELECTRIC SYSTEM CONNECTEDLABEL 10AT UTILITY METER (5 3/4" X 1 1/8")[NEC 690.56(B)]RAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL 5AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2").[NEC 690.56(C)(3)].39.93AV240BACKFRONTMAIN DISTRIBUTIONUTILITY DISCONNECTPV ARRAY SHEET KEYNOTES1. ROOF MATERIAL: ASPHALT SHINGLE2. ROOF STRUCTURE: TRUSS3. ATTACHMENT TYPE: IRONRIDGE FLASHFOOT24. MODULE MANUFACTURER: LG ELECTRONICS5. MODULE MODEL: LG370N1K-E66. MODULE LENGTH: 69.6 IN.7. MODULE WIDTH: 41 IN.8. MODULE WEIGHT: 40.78 LBS.9. SEE SHEET A-103 FOR DIMENSION(S)10. MIN. FIRE OFFSET: 18" FROM RIDGE, 36" FROM EDGE.11. TRUSS SPACING: 24 IN. O.C.12. TRUSS SIZE: 2Х4 IN. NOMINAL13. LAG BOLT DIAMETER: 5/16 IN.14. LAG BOLT EMBEDMENT: 2-1/4 IN.15. TOTAL # OF ATTACHMENTS: 6316. TOTAL AREA: 653.95 SQ. FT.17. TOTAL WEIGHT: 1577.62 LBS.18. WEIGHT PER ATTACHMENT: 25.04 LBS.19. DISTRIBUTED LOAD: 2.41 PSF20. MAX. HORIZONTAL STANDOFF: 48 IN.21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITHMODULE MANUFACTURER'S INSTRUCTIONS22. STANDOFF STAGGERING: YES23. RAIL MANUFACTURER (OR EQUIV.): IRONRIDGE24. RAIL MODEL (OR EQUIVALENT): XR10025. RAIL WEIGHT: 0.68 PLF.26. MAX. TRUSS SPAN: 20 FT.27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.S-501D52011121413151822ROOF SLOPE 910106217S-501D4315425242382721. FIELD VERIFY ALL MEASUREMENTSGENERAL NOTESBFAD E23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:AC D EG HB CF G H1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCES-501.00ASSEMBLY DETAILS(SHEET 9)D4DETAIL (TRANSVERSE)NOT TO SCALED5DETAIL (LONGITUDINAL)NOT TO SCALED1RACKING DETAIL (TRANSVERSE)NOT TO SCALED3RACKING DETAIL (TOP)NOT TO SCALED2RACKING DETAIL (LONGITUDINAL)NOT TO SCALE10.18.22 BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCER-001.00RESOURCE DOCUMENT(SHEET 10) BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCER-002.00RESOURCE DOCUMENT(SHEET 11) BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCER-003.00RESOURCE DOCUMENT(SHEET 12) BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCER-004.00RESOURCE DOCUMENT(SHEET 13) BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCER-005.00RESOURCE DOCUMENT(SHEET 14) BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDDESIGN BY:ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:REVISIONS GOLDEN ELECTRIC LLC4250 INLAND LANE NORTHPLYMOUTH, MN 55446763-412-5714P.V.M.M.09.02.2022EA796843PAPER SIZE: 11" x 17" (ANSI B)NEW PV SYSTEM:DC 12.210 kWp / AC 9.570 kWp19301 IMPALA AVELAKEVILLE, MN 55044APN: 227335301110PENROSERESIDENCER-006.00RESOURCE DOCUMENT(SHEET 15)