HomeMy WebLinkAboutLA207753 - APPROVED - Blake Wengenroth Solar Drawings wStamp 10.24.2022EXISTINGSNAPNRACKSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAM ATTACHMENT LAYOUTSYSTEM LABELING DETAILENPHASE RAPID SHUTDOWNINVERTER DATA SHEETSHEET INDEXPROPERTY PLANMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0PV 2.0PV 4.0PV 5.1D 6.0D 7.0D 8.0D 9.0D 10.0D 11.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE PANEL BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:Truss 2 x 4 @ 24" O.C.Comp ShingleVICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record print to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.150A150A10/24/2022Property Address:Owner:Blake WengenrothProperty Type:Single Family ResidenceDrawn by:New@engineerinc.ioDate: HANWHA 400 WATT MODULESWITH IQ8+ MICROINVERTERS17184 Gage Way Farmington, MN 55024CONTRACTORAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comTHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2020 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESINVERTER CERTIFICATIOND 13.0PV 3.1ENPHASE AC COMBINER BOXD 12.0PV INSPECTION CHECKLIST ATTACHMENT DETAILPV 5.2SURGE PROTECTIOND 14.0PLACARDPV 3.2DC 10.00 KW STCAC 7.25 KW STC25MILBANK DATA SHEETD 15.0GDate Certified andSigned: 10/24/2022 EMT type ConduitSolar Module(N) Junction BoxJB.................................................................................MSP(E) Main Service Panel150AINDEXAC.................... (N) 60A Utility AC(N) MicroinverterNOTE: Conduit in attic shallbe minimum 18 inches from roof sheatingSITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Drawn by:New@engineerinc.ioProject Name:Property Address:10/24/2022Blake Wengenroth17184 Gage WayFarmington, MN 55024DATE:CONTRACTORECB(N) Enphase Combiner Box....Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENT(E) Main MeterMM...................Fire Setback Line.............SECONDARY INTERCONNECTIONFMT type Conduit.............SOLAR MODULES___HANWHA 400 WattModel #Q.PEAK DUO BLK ML-G10+2525INVERTERINVERTER TYPE: Micro:___ Enphase IQ8PLUSModel # IQ8PLUS-72-2-US(240V) Dakota ElectricEQUIPMENT ELEVATIONECB Utility ACDisconnect4'10"From roofMainServicePanel<10"PerformanceMeter(N) Performance MeterPM.............Total Roof Area:2908Total Module Area:55018.91% of CoverageOutsideInsideInsideOutsideMainMeterNOTE: No clearance issue Distance between all equipments is maximum 10"<10'Note:Keep 3ft clearance from gas meter and AC unit.Gage WayJB1JB2MSPMMPMACECBaaaaaaaaaaaababbbbbbbbbbbSolar PV Array25-Hanwha 400 W Modules25 - IQ8+ MicroinvertersPitch: 20 DegOrientation: 181 DegSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNENo less than 18 inch clearsetback is required on bothsides of a horizontal ridge,valley, or hipFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode10/26/2022dpfannenstein (3) #8 AWG THWN/THWN-23/4" SCH 80 PVC, 2 FEETENPHASE Q CABLE(2) #12 AWG PV WIRE(1) #6 AWG EGCFREE IN THE AIRPV 2.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024ELECTRICAL 1-LINE DIAGRAMCONTRACTOREnphasePV MONITORING DEVICEENPHASE IQ COMBINER 4120/240V, 1P,3W NEMA 3R(2) #14 AWG THWN/ THWN-210A 2-POLENote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDesign meet National Electric Code(NEC codes)60A FUSED AC DISCONNECT,WITH 40A FUSES UTILTY AC DISCONNECT VISIBLE-OPENLOCKABLE, READILY ACCESSIBLENEMA3R120 / 240V 1P,3WINSTALL (2)20A PV2-POLE C/B EXISTING______ MAINSERVICEPANEL120/240V,1P, 3WGEC(E) GROUNDINGELECTRODE SYSTEM150ASECONDARY INTERCONNECTIONREFERENCE POINT OF APPLICABILITY (4) #12 AWG THWN/THWN-2 (1) #12 AWG GND 3/4'' EMT, 7 FEETSurge ProtectionMNSPD-300-ACDrawn by:New@engineerinc.io10/24/2022DATE:1-PHASE MICRO-INVERTER UL1741HANWHA 400 WATT MODULES2525ENPHASE IQ8PLUS MICROINVERTERSSYSTEM RATING AND DER POWER OUTPUTINVERTER:ENPHASE IQ8PLUS-72-2-USINVERTER MAXIMUM CONTINUOUS OUTPUT:290VASYSTEM POWER OUTPUT:ENPHASE IQ8PLUS MICROINVERTERS1 PHASE 290VAMAXIMUM OUTPUT CURRENT 1.21AAC PORT BACKFEED CURRENT 0ADC SHORT CIRCUIT CURRENT 15ADC 10.00 KW STCAC 7.25 KW STCDC 10.00 KW STCAC 7.25 KW STC Dakota Electric30.25A30.25A25x 290 =7.25Utility PV production meter socket withstamped brass aluminium or stainlesssteel tag labeled in accordance with NECand AHJ requirments located within 5' ofmain. Inverter output wired to load sideterminal of meter 1 phase 3-wire120/240V30.25ALoad(3) #8 AWG THWN/THWN-23/4" SCH 80 PVC, 2 FEETPV Production meter socket must have leverbypass/bypassProduction meter is required based on the der sizeand program under which the application is submittedNo loads or energy storage systems shall beconnected on the DER side of the production meterNOTE: AC DISCONNECT VISIBLE AND LOCKABLE (3) #8 AWG THWN/THWN-2 (1) #8 AWG GND 3/4'' SCH 80 PVC, 7 FEETMAIN METER120/240V1P,3W(1) #6 AWG GND(NEW)GECAdd 2nd Ground rod andtie it to the existing ground rod.14.52A1BRANCHCIRCUIT-A2 15.73A13Line SIde TapJ BOX2NEMA3R1BRANCHCIRCUIT-B212 EXISTINGNON CENTER _____MAIN C/B150AAtticWall (4) #12 AWG THWN/THWN-2 (1) #12 AWG GND 3/4'' FMT, 10 FEETLoadLineNote:Keep 3ft clearance from gas meter and AC unit.J BOX1NEMA3RProperty Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:30.25APV 3.1SYSTEM LABELING DETAILProduction MeterLABEL 1PV ARRAYJ BOXPV SUB-PANELACDISCONNECTMAIN SERVICEPANELMETER233331716218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTRATED MAX POWER-FONT CURRENTRATED MAX POWER-FONT VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTMAX RATED OUTPUT CURRENT OFTHE CHARGE CONTROLLER IF INSTALLEDLABEL 21***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECT21PerformanceMeter13SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSProperty Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com PLACARDPV 3.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORCAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 1 OF 2CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 2 OF 2NWESNWESDrawn by:New@engineerinc.io10/24/2022DATE:17184 Gage WayFarmington, MN 5502417184 Gage WayFarmington, MN 55024Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comPERFORMANCE METERPV SYSTEM DISCONNECTFOR UTILITY OPERATIONENPHASE COMBINER BOXSERVICE POINT &UTILITY METERINGSOLAR PV ARRAYPERFORMANCE METERPV SYSTEM DISCONNECTFOR UTILITY OPERATIONENPHASE COMBINER BOXSERVICE POINT &UTILITY METERINGSOLAR PV ARRAY PROPERTY PLANLEGENDMSPMain Service Panel................PV 4.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTOREnphase Combiner BoxECB..........MMMain Meter.........................Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by:New@engineerinc.io10/24/2022DATE: Dakota ElectricPerformance MeterPM...................AC........................ AC DisconnectProperty Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comGage WayMSPMMPMACECB33'-7"87'132'109'-3"112'26'-3"43'-6"28'-5"75'-6"DrivewayPROPERTY LINESCALE:1/16" = 1'-0" 180° 90° 270°0°SWNEDate Certified andSigned: 10/24/2022G ATTACHMENTLAYOUTDESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules48.5Total Module Weight (lbs)Rack Weight (lbs)MicroInverters Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)1212.5242.559.51514.5504830.295502.75RAIL ATTACHMENTTruss 2 x 4 @ 24" O.C.2525PV 5.1PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTOR1 Layer of .Plywood & Building FeltSolar Module6"AttachmentROOF SECTION DETAILSTruss 2 x 4 @ 24" O.C.Comp ShinglePrior to the commencement of work, the contractor shall verify the existing roof and framingconditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction.Prior to the commencement of work, the contractor shall inspect framing for any damagesuch as water damage, cracked framing, etc. and These Plans are stamped for structuralcode compliance of the roof framing supporting the proposed PV installation reference only.These plans are not stamped for water leakage. PV modules, racking, and attachmentcomponents must follow manufacturer guidelines and requirements. Attachments to beinstalled in a staggered orientation to properly distribute loads.1.86"3.05"0.25"Ø2.24"2.58"1"0.17"3.20"1.37"0.38"0.30"1.08"2.78"1.78"1.50"1.99"1.21"R 1.12"Ø0.33"R 0.82"12345SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/BLACKBOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SSSNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SSSNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/BLACKSNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/BLACK12345DESCRIPTIONITEMQTI11111MATERIALS:DESIGN LOAD (LBS):ULTIMATE LOAD (LBS):TORQUE SPECIFICATION:CERTIFICATION:WEIGHT (LBS):DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINESS STEEL802 UP, 1333 DOWN, 357 SIDE2118 UP, 4006 DOWN, 1331 SIDE12 LB-FTUL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 25820.45OPTIONS:CLEAR/BLACKPARTS LISTSNAPNRACK, ULTRA RAIL SPEEDSEAL TM FOOTNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by:New@engineerinc.io10/24/2022DATE: Dakota ElectricProperty Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com20'-2"13'Date Certified andSigned: 10/24/2022G PV 5.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024ATTACHMENT DETAILCONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDate Certified andSigned: 10/24/2022G INVERTERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com ENPHASE RAPIDSHUTDOWN,COMPATIBILITY WITH PVD 7.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com MODULEDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com RACKINGDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com ATTACHMENTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 11.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORENPHASEAC COMBINER BOXDATASHEETDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 12.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORINVERTERCERTIFICATIONDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORSURGE PROTECTIONDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 14.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Blake Wengenroth17184 Gage WayFarmington, MN 55024PV INSPECTIONCHECKLISTCONTRACTORWolf RIver ElectricFarmington, MN 5502417184 Gage WayDrawn by:New@engineerinc.io10/24/2022DATE:Property Address:Wolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 15.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Blake Wengenroth17184 Gage WayFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comMILBANKDATA SHEETDrawn by:New@engineerinc.io10/24/2022DATE: