Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA207884 - APPROVED - Greg Roberts - PERMIT-PE LETTER-PLANS
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov LH - Email 10.28.2022 $201.00 Bldg and Elect Total $242.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: X X (solar) 200.00 1.00 201.00 DP Rooftop Solar (12 Panels) IRC-1 V-B 2020 RS-3 10/28/22 :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW 5REHUWV5HVLGHQFH WK6W: /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH5REHUWV5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUW DOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD 6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU '0DLQOLQH'U :HVWILHOG0$ 'DWH2FWREHU 5HI Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 10/28/2022dpfannenstein Provide copy of city approved plans on the job site for the inspector For each roof plane with a photo-voltaic array, a 36 inch wide pathway shall be provided from lowest roof edge to ridge on the same roof plane, on adjacent roof planes. One shall be on street/driveway side. No less than 18 inch clear setback is required on both sides of a horizontal ridge, valley, or hip Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 10/28/2022dpfannenstein LG370N1K-A6 About LG Electronics USA, Inc. LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group’s vast experience in the semi-conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully released its first MonoX® series to the market, which is now available in 32 countries. The NeON® (previous MonoX® NeON), NeON®2, NeON®2 BiFacial won the “Intersolar AWARD” in 2013, 2015 and 2016, which demonstrates LG’s leadership and innovation in the solar industry. 60 When you go solar, ask for the brand you can trust: LG Solar 370W Features Enhanced Performance Warranty LG NeON® 2 Black has an enhanced performance warranty. After 25 years, LG NeON® 2 Black is guaranteed at least 90.6% of initial performance. Roof Aesthetics LG NeON® 2 Black has been designed with aesthetics in mind using thinner wires that appear all black at a distance. Solid Performance on Hot Days LG NeON® 2 Black performs well on hot days due to its low temperature coefficient. 25-Year Limited Product Warranty The NeON® 2 Black is covered by a 25-year limited product warranty. In addition, up to $450 of labor costs will be covered in the rare case that a module needs to be repaired or replaced. yrs25 Warranty The LG NeON® 2 is LG’s best selling solar module and one of the most powerful and versatile modules on the market today. The cells are designed to appear all-black at a distance, and the performance warranty guarantees 90.6% of labeled power output at 25 years. I-V Curves General Data Cell Properties (Material/Type)Monocrystalline/N-type Cell Maker LG Cell Configuration 60 Cells (6 x 10) Number of Busbars 12EA Module Dimensions (L x W x H)1,740mm x 1,042mm x 40 mm Weight 18.6 kg Glass (Material)Tempered Glass with AR coating Backsheet (Color)Black Frame (Material)Anodized Aluminium Junction Box (Protection Degree)IP 68 with 3 Bypass Diodes Cables (Length)1,100mm x 2EA Connector (Type/Maker)MC 4/MC Electrical Properties (NMOT) Model LG370N1K-A6 Maximum Power (Pmax)[W]277 MPP Voltage (Vmpp)[V]33.3 MPP Current (Impp)[A]8.32 Open Circuit Voltage (Voc)[V]39.4 Short Circuit Current (Isc)[A]8.81 Temperature Characteristics NMOT*[°C] 42 ± 3 Pmax [%/°C]-0.35 Voc [%/°C]-0.26 Isc [%/°C] 0.03 *NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 LG370N1K-A6 LG Electronics USA, Inc.Solar Business Division2000 Millbrook DriveLincolnshire, IL 60069 www.lg-solar.com Product specifications are subject to change without notice. LG370N1K-A6_AUS.pdf 020221 © 2021 LG Electronics USA, Inc. All rights reserved. 1042.0 / 41.0 (Size of Short Side)320.0 / 12.61002.0 / 39.4 (Distance between Grounding & Mounting Holes) 175.0 / 6.9 1100 / 43.3 Cable Length 40.0 / 1.57 105.0 / 4.1220.0 / 8.616 - 8.0 x 3.0 / 0.3 x 0.1 Drain Holes 8 - Ø4.3 / 0.2 Grounding Holes 8 - 8.5 x 12.0 / 0.3 x 0.5 Mounting Holes Junction Box 1100.0 / 43.3 (Distance between Mounting Holes)1300.0 / 51.2 (Distance between Mounting Holes)1740.0 / 68.5 (Size of Long Side)200W 400W 600W 800W 1000W Voltage [V]Current [A]12.0 10.0 8.0 6.0 4.0 2.0 0.0 0.0 10.05.0 20.015.0 30.025.0 45.040.035.0 Operating Conditions Operating Temperature [°C] -40 ~+85 Maximum System Voltage [V]1,000 (UL/IEC) Maximum Series Fuse Rating [A]20 Mechanical Test Load* (Front)[Pa/psf]5,400 Mechanical Test Load* (Rear)[Pa/psf]4,000 Mechanical Test Loads 6,000Pa/5,400Pa based on IEC 61215:2005 *Based on IEC 61215-2 : 2016 (Test Load = Design Load x Safety Factor (1.5)) Packaging Configuration Number of Modules per Pallet [EA]25 Number of Modules per 40' Container [EA]650 Number of Modules per 53’ Container [EA]850 Packaging Box Dimensions (L x W x H)[mm]1,790 x 1,120 x 1,213 Packaging Box Dimensions (L x W x H)[in]70.5 x 44.1 x 47.8 Packaging Box Gross Weight [kg]500 Packaging Box Gross Weight [lb]1,102 Dimensions (mm/inch) Certifications and Warranty Certifications* IEC 61215-1/-1-1/2 : 2016, IEC 61730-1/2 : 2016, UL 61730-1 : 2017, UL 61730-2 : 2017 ISO 9001, ISO 14001, ISO 50001 OHSAS 18001 Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Ammonia Corrosion Test IEC 62716:2013 Module Fire Performance Type 2 (UL 61730) Fire Rating Class C (UL 790, ULC/ORD C 1703) Solar Module Product Warranty 25 Year Limited Solar Module Output Warranty Linear Warranty* *Improved: 1st year 98.5%, from 2-24th year: -0.33%/year down, 90.6% at year 25 *STC (Standard Test Condition): Irradiance 1000 W/m2, cell temperature 25°C, AM 1.5 Measurement Tolerence of Pmax: 3%+- Electrical Properties (STC*) Model LG370N1K-A6 Maximum Power (Pmax)[W]370 MPP Voltage (Vmpp)[V]35.5 MPP Current (Impp)[A]10.43 Open Circuit Voltage (Voc 5%)[V]41.9 Short Circuit Current (Isc 5%)[A]10.96 Module Efficiency [%]20.4 Power Tolerance [%]0 ~ +3 +- +- IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SP-DS-0002-01-EN-US-2021-10-19 DATA SHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/ module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current2 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.5 97.6 CEC weighted efficiency %97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-DS-0002-01-EN-US-2021-10-19 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 1.00 4.20 .30 3.25 1.00 1.00SLOT 1.50 2.781.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM .35 1.80 105° DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³