Loading...
HomeMy WebLinkAboutLA208343-APPROVED - Engineering Certification of SM-MNEngineering Alliance, Inc https://www.eng-alliance.com 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757 11-November-2022 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87101 Tel: 505 242 6411 Attn.: Engineering Department Subject: Engineering Certification for the Unirac SOLARMOUNT Flush Rail System to Support Photovoltaic Panels. The Unirac SOLARMOUNT Flush-to-Roof is an extruded aluminum rail system that is engineered to hold most framed solar modules to a roof structure and installed parallel to the roof. We have reviewed the SOLARMOUNT system, a proprietary mounting system constructed from modular parts which are intended for rooftop installation of solar photovoltaic (PV) panels; and have reviewed the U-Builder 2.0 Online tool. This U- Builder 2.0 software includes analysis for the SOLARMOUNT rails (SM LIGHT rail, SM STANDARD rail, and SM HEAVY DUTY rail) with Standard and Pro Series hardware. All information, data, and analysis are in compliance with the following codes, city ordinances, and typical specifications: Codes: 1. ASCE/SEI 7-16 Minimum Design Loads for Buildings and other Structures 2. 2020 Minnesota Building Code, w/ Provisions from SEAOC PV-2 2017 3. 2020 Minnesota Residential Code, w/ Provisions from SEAOC PV-2 2017 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5. Aluminum Design Manual, 2015 & 2020 Edition Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-Builder 2.0 Engineering report. Cantilever: The maximum cantilever length is L/3, where “L” is the span noted in the U-Builder 2.0 online Tool. Clearance: 2” to 10” clear from top of roof to top of PV panel Tolerance(s): 1.0” tolerance for any specified dimension in this report is allowed for installation Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the short side. Engineering Alliance, Inc https://www.eng-alliance.com 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757 Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, 7-10 & 7-16 Component and Cladding design. Notes: 1. U-Builder 2.0 Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems and do not include roof capacity check. 2. Risk Category II per ASCE 7-16. 3. Topographic factor, kzt is 1.0. 4. Array Edge Factor ƳE = 1.5 5. Average parapet height is 0.0 ft. 6. Wind speeds are LRFD values. 7. Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder 2.0 design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-Builder 2.0 software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder 2.0 Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder 2.0 software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder 2.0 engineering report and the manufacture specifications are in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. Please feel free to call for any questions or clarifications. Prepared By: Engineering Alliance, Inc Sugar Land, TX Professional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Saddam Ahmad Date: License Number: 5538111-NOV-2022 Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 11/16/2022dpfannenstein Provide copy of city approved plans on the job site for the inspector