Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA208314-APPROVED - Michael Lorenz - PERMIT APPLICATION-PLANS
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov LH - email 11.15.2022 $201.00 Bldg and Elect Total $242.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: X X (solar) 200.00 1.00 201.00 DP Rooftop Solar (12 Panels) 11/16/22 V-B 2020 IRC-1 RS-3 :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW /RUHQ]5HVLGHQFH *UHHQEULDU&W /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH/RUHQ]5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUW DOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD 6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU '0DLQOLQH'U :HVWILHOG0$ 'DWH2FWREHU 5HI Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 11/16/2022dpfannenstein Provide copy of city approved plans on the job site for the inspector ~129.27 '~85.00'~129.72 '~85.00'35'-1"17'-10"32'-7 "12'-2"MSPUMCBACDPMSITE PLAN WITH ROOF PLANSHEET NUMBERPV-1 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :200003369329METER NUMBER : 1ND90305540PREMISE NUMBER : N/ACASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR09/23/2022INITIAL RELEASESHEET NAMEPROJECT NAMEMICHAEL LORENZ 16307 GREENBRIAR CT, LAKEVILLE, MN 55024 USA APN# 221700202300 UTILITY: DAKOTA ELECTRIC ASSOCIATION AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (952) 239-5335SITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:A. ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC.SHALL NOT BE INSTALLED WITHIN 3’ OF THEGAS METERS’ SUPPLY OR DEMAND PIPING.INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8M-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45AOPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METER(12) REC SOLAR REC400AA PURE BLACK (400W) MODULES(12)ENPHASE IQ8M-72-2-US MICRO-INVERTERS(02) BRANCHES OF 06 MODULES CONNECTED IN PARALLELDISTANCESSOLAR PANELS - INVERTER: 24' MAXINVERTER - IQ COMBINER PANEL: 75' MAXIQ COMBINER PANEL - UTILITY AC DISCONNECT: 2'UTILITY AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - MAIN ELECTRIC SERVICE: 2'MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 2'NOTES:1. LOCATION OF SERVICE PANEL AND ELECTRICALEQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE.2. LOCATION OF SERVICE PANEL AND ADDITIONALELECTRICAL EQUIPMENT NOT DRAWN TO SCALE.3. PV INTERCONNECTION IS A SECONDARYINTERCONNECTION4. AC DISCONNECT AND PRODUCTION METER IN READILYACCESSIBLE LOCATION WITHIN 10' OF MAIN READILYSERVICE METER/BI-DIRECTIONAL METER. 24/7UNESCORTED KEYLESS ACCESS TO BE PROVIDED FORUTILITY AC DISCONNECT, PV PRODUCTION METER, &BI-DIRECTIONAL METER.5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEWITH NEC 690 AND POSTED WITH APPLICABLEWARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10,690-17, & 690-64 (b)(5).6. THERE ARE NO CLEARANCE ISSUES DUE TOOVERHEAD POWERLINES.LABELS LOCATED ON PV PRODUCTION METER,BI- DIRECTIONAL METER, AC DISCONNECT (S),INVERTER(S), AND APPROPRIATE LABELS ON MAINELECTRIC SERVICE. ALL LABELS ARE PERMANENT,WEATHERPROOF.(E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 4(N) XCEL ENERGY PRODUCTION METER120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE(E)125A MAIN SERVICE PANEL WITH(E)100A MAIN BREAKER (INSIDE)EXISTINGDRIVEWAY PROPERTY LINEPROPERTY LINE PROPERTY L INE PROPERTY LINEGREENBRIAR CTTWO- STORYHOUSEROOF #1(12)REC SOLAR REC400AA PUREBLACK (400W) MODULES(N) UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLE(E) STRUCTURE10' MAX(E) TREE (TYP.)GREENBRIAR LANE 2'-8"12'-0"1'- 6 "1'-4"27'-3"23'-9"MSPUMCBACDPMSHEET NUMBERPV-2 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :200003369329METER NUMBER : 1ND90305540PREMISE NUMBER : N/ACASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR09/23/2022INITIAL RELEASESHEET NAMEPROJECT NAMEMICHAEL LORENZ 16307 GREENBRIAR CT, LAKEVILLE, MN 55024 USA APN# 221700202300 UTILITY: DAKOTA ELECTRIC ASSOCIATION AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (952) 239-5335ROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 3/32" = 1'-0"171.7"40"PHOTOVOLTAIC MODULESREC SOLAR REC400AA PURE BLACK (400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 12 MODULESMODULE TYPE = REC SOLAR REC400AA PURE BLACK(400W) MODULESMODULE WEIGHT = 45 LBS / 20.5 KG.MODULE DIMENSIONS = 71.7"X 40" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSFNOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAYR324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:2657.59 sqftAREA OF ARRAYS:71.7"X 40" ( PANEL DIMENSIONS)71.7"X 40" = 19.92 sqft (PER PANEL)19.92 sqftpanel X 12 panels = 239.00 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(239.00 sqft / 2657.59 sqft)(100)= 8.99%∴ THE PANELS USE 8.99% OF THETOTAL ROOF AREABILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONRAIL06 SNAP N RACK UR-40 RAILSPLICE02RAIL SPLICEMID CLAMP18 MODULE MID CLAMPEND CLAMP12 MODULE END CLAMPATTACHMENT 27 SNAP N RACK UMBRELLA SEALGROUNDING LUG 03 GROUNDING LUGLEGENDUM- UTILITY METERMSP- MAIN SERVICE PANELACD- AC DISCONNECTCB- COMBINER BOX 4PVM- PRODUCTION METER- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT-TRUSSESROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#122° 240° 2"X4" 24" O.C.18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY36 " F IRE PATHWAYGREENBRIAR CTFRONT YARDREAR YARD(E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 4(N) XCEL ENERGY PRODUCTION METER120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE(E)125A MAIN SERVICE PANEL WITH(E)100A MAIN BREAKER (INSIDE)(N) UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLEROOF #1(12)REC SOLAR REC400AA PUREBLACK (400W) MODULES(E)COMP SHINGLE ROOF (TYP.)(N) (27) SNAP N RACK UMBRELLA SEALATTACHMENTS SPACED AT 48" O.C.(N)SNAP N RACK UR-40 RAIL(E)2"X4" TRUSSES @ 24" O.C. (TYP.)10' MAXConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode11/16/2022dpfannensteinNo less than 18 inch clearsetback is required on bothsides of a horizontal ridge,valley, or hipFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side. SHEET NUMBERPV-3 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :200003369329METER NUMBER : 1ND90305540PREMISE NUMBER : N/ACASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR09/23/2022INITIAL RELEASESHEET NAMEPROJECT NAMEMICHAEL LORENZ 16307 GREENBRIAR CT, LAKEVILLE, MN 55024 USA APN# 221700202300 UTILITY: DAKOTA ELECTRIC ASSOCIATION AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (952) 239-5335ATTACHMENTDETAIL SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITHUMBRELLA FLASHING FOR COMPOSTION ROOFMOUNTINGMODULE HEIGHT OFF ROOF, RANGE:UR-40: 338" - 43UR-60: 4" - 5"REFER TO SNAPNRACK ENGINEERING CHARTS FORAPPLICABLE RAIL SPANS. "BIN" NUMBER ON CHARTSHOULD MATCH "BIN" NUMBER ON THIS DRAWING5OF 2116"∴ S.S. UMBRELLA LAG SCREW MUST EMBED A MIN.2" INTO STRUCTURAL MEMBERREFER TO SNAPNRACK INSTALLATION MANUAL FOR516"∴ HARDWARE TORQUE SPECIFICATIONSRAIL CAN BE MOUNTED ON EITHER SIDE OF THEL-FOOTFOR LEVELING DETAILS, REFER TO SNAPNRACKDETAIL DRAWING "SNR-DC-00332 ULTRA RAIL,COMPONENT DETAIL, LEVELING EXTENSION KIT"SNAPNRACKULTRA RAIL8"SNAPNRACK ULTRA RAILUMBRELLA L-FOOTSNAPNRACK 516"∴ S.S.UMBRELLA LAG SCREW, TYP.STRUCUTRAL MEMBER,WOOD RAFTER, TYP.COMP SHINGLE ROOFING, TYP.ROOF DECKING, TYP.SNAPNRACK EPDM UMBRELLA GASKET(SEALS UMBRELLA LAG AND UMBRELLA CONE)212" MIN. EMBEDMENTINTO WOOD MEMBERPENETRATION DETAILFLASHING SHOULD EXTENDTO END OF DOWNSLOPESHINGLE COURSESNAPNRACK UMBRELLA FLASHINGMUST SLIP BENEATH THE UPSLOPESHINGLE COURSEUMBRELLA CONE ONFLASHING TO SHIELD WATER11112"21158"UR-40 RAIL | UR-60 RAILFOR USE WITH SNAPNRACK ULTRA SERIES RAILS4"2"AROOF DECKINGDETAIL ASTRUCTURAL MEMBER (RAFTER)INSTALLED SECTION VIEW 18'-5"17'-3"23'-0"25'-0"SHEET NUMBERPV-4 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :200003369329METER NUMBER : 1ND90305540PREMISE NUMBER : N/ACASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR09/23/2022INITIAL RELEASESHEET NAMEPROJECT NAMEMICHAEL LORENZ 16307 GREENBRIAR CT, LAKEVILLE, MN 55024 USA APN# 221700202300 UTILITY: DAKOTA ELECTRIC ASSOCIATION AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (952) 239-5335ELEVATION PLANWINDOW (TYP.)FRONT SIDE OF HOUSEELEVATION PLANSCALE: NTS1PV MODULES rec Alphα® pure Black Series Product Specifications α experience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 385 390 395 400 405 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14 Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3 Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9 Power Output - PMAX (Wp)293 297 301 305 309 Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 132 half-cut REC heterojunction cells with lead-free, gapless technology 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm) Weight:45 lbs (20.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:-40 ... +185°F (-40 ... +85°C) Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq ft)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending) ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01-EN-US-2021-10-19 DATA SHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/ module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters INPUT DATA (DC)IQ8M-72-2-US IQ8A-72-2-US Commonly used module pairings1 W 260 – 460 295 – 500 Module compatibility 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 33 – 45 36 – 45 Operating range V 25 – 58 Min/max start voltage V 30 / 58 Max input DC voltage V 60 Max DC current2 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8M-72-2-US IQ8A-72-2-US Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit4 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.6 97.6 CEC weighted efficiency %97 97.5 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MA-DS-0003-01-EN-US-2021-10-19 snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience SnapNrack Umbrella Sealing Technology • Innovative Flashing Elevates Protection. New fl ashing uses a fully formed raised cone to prevent any potential water from getting into penetration. Feel secure as the fl ashing is one piece and doesn’t rely on multiple parts sealing together. • Mechanical Design Creates a Lifelong Seal. Patented Umbrella technology utilizes unique Umbrella Washer to seal lag bolt, L Foot, and fl ashing and prevent any potential roof leaks. Technology passes UL 2582 Wind Driven Rain Test without a rubber seal, however rubber gasket is included for extra peace of mind. • Single Fastener Eliminates Extra Steps. Utilize one lag bolt with Umbrella Washer to secure the entire mount assembly and fl ashing. No longer necessary to attach a base, then a fl ashing, then a mount as all are secured in one step. • Single Tool Installation. SnapNrack was the fi rst in the industry to develop a complete system that only requires a single tool. That tradition is continued as a ½” socket is still the only tool necessary to secure the mount as well as all other parts of the system. snapnrack.com Featuring New Innovative Flashing Smaller 9”x12” size allows for easier insertion under shingles Alignment markers make it easy to locate pilot holes Rounded corners make for easier insertion & eliminate corner points from folding up Note: Flashing shown in yellow for illustration purposes only. © 2018 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com snapnrack.com Ultra Rail, UR-40 Rail System Spans Wind (mph) 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 Snow (psf)0 5 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 120 System Span Key 6 ft Spans 4 ft Spans 2 ft Spans This table was prepared in compliance with applicable engineering codes and standards. Values are based on the following: • ASCE 7-10 • Chapter 30 Wind Loads & Chapter 7 Snow Loads • Roof Slope: 7 - 27 deg • Roof Height: 0 - 30 ft • Exposure: B • Roof Zone: 1 • Module Orientation: Portrait • Module Type: 60 Cell Modules • Roof Type: Comp Industry Leading Spans for a Light Rail Solution Visit SnapNrack.com for detailed span tables and certifi cations. Certifi cations SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 for wind-driven rain. Raised Cone Flashing Single Lag Secures Mount to Roof Pre-assembled Ultra Rail L Foot & Clamp Pre-assembled Ultra Rail