Loading...
HomeMy WebLinkAboutLA208532THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION: Please complete a separate application form for each sign. Payment for amount of permit. For freestanding/monument/pylon sign - a site plan with setback from property line dimensions and art work with dimensions of sign, and engineered design for footings and foundation. For wall sign, art work with dimensions of sign and drawings of building façade showing location of sign. If illuminated or if electrical services are needed, a separate electrical permit is required. If leased space, need to include a letter of approval from the property owner. SIGN LOCATION Name_______________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ PROPERTY OWNER Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN CONTRACTOR Company Name _________________________________________________________________________ Address________________________________________________________________________________ City ___________________________________ State___________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN DESCRIPTION Electronic ($100 per sign plus completion of electronic sign license, see Page 2) (1000.4114) Permanent ($75 per sign) (1000.4114) Temporary ($50 per event, up to 60 days per year. Max of one temp sign displayed at a time.) (1000.4114) Temporary sign displayed dates: START DATE ________________________ END DATE ________________________ Sign Type and Dimensions Wall Sign: Width ____________ Height: _______________ Square feet _____________________________ Freestanding: Face Width_________ Height____________ Sq. ft__________ Overall Sign Height _________ Setbacks: Front _________ Side ____________ Temporary Width___________ Height ______________ Sign Square Feet______________________ Display location _______________________ Illuminated Sign: Internally illuminated Externally illuminated Not illuminated Type of Work: New Sign Replacement Sign Alter Existing Sign Changeable Copy: No Changeable Copy Manual Changeable Copy Electronic Changeable Copy (Electronic sign will require annual license review & renewal, see Page 2) Applicant Signature: ____________________________________________Date:_________________ Applicant Printed Name: _______________________________________________________________ SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION City of Lakeville – Planning Department 20195 Holyoke Avenue - Lakeville, MN 55044 952.985.4420 - www.lakevillemn.gov Premier Martial Arts 20137 Idealic Ave Lakeville MN 55044 Rana Kuebker 651-357-1125 rkuebker@signartusa.com Signart Co Inc 2170 Dodd Rd Mendota Heights MN 55120 Rana Kuebker 651-357-11258 rkuebker@signartusa.com Rana Kuebker 11/21/2022 515 CONGRESS AVE STE 1925 78701Austin TX JASON MADDOX P: 602.278.6286 dane@royalsign.net Dan Alvold - Tenant Agent 14' 5 1/2"2'- 5 1/8" 35.08 LA208532 SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION Page 2 Electronic Display/Changeable Copy Sign License By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every seven (7) seconds. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9.The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED APRIL 2022) PUDX X X $75.00 $75.00 23 November, 2022 X *Email kjenson@lakevillemn.gov after installation for final inspection. 2631 N. 31st Ave. Phoenix, AZ 85009 602-278-6286 royalsign.net Client: Location: Sheet Title Page Number Project Manager: E-Mail: 221366Project Approval Signatures Client Landlord This original unpublished drawing is submitted solely for the project being planned. It is not to be copied or shown to persons outside of your organization without express written authorization from ROYAL SIGN COMPANY.All specified details on these drawings are subject to change due to the availability of materials and/or changes in the method of fabrication. ROYAL SIGN COMPANY will do their best to maintain the design intent of these drawings at all times. If the owner or owners’ representative wishes to receive detail drawings on all changes during the fabrication process, ROYAL SIGN COMPANY must be advised in writing prior to the start of fabrication. Customer is responsible for providing a dedicated electrical circuit within six feet of each sign location and any desired electrical timing devices. Dane Alvord dane@royalsign.net Exterior 2 6of n/a n/a n/a n/a n/a n/a n/a n/a n/a 20137 Idealic Ave Lakeville, MN 55044 Premier Martial Arts (Lakeville) X X 1 2 3 4 5 6 7 8 9 10 31 OCT 22 TD Southeast Elevation Scale 1/8” = 1’-0” INTERNALLY-ILLUMINATED PAN CHANNEL DISPLAYA Scale: 1/2” = 1’-0” Sign Area 35.08 sf Fabricate and install one (1) internally-illuminated, aluminum, pan channel wall display; 3” deep returns (black); white acrylic faces w/ black trim cap. Faces to be overlaid w/ custom GREEN vinyl. Illuminate using white LEDs to raceway-mounted power supplies (see detail). *Size allowance: NTE 36” overall height, 80% frontage length Sign Area PERSPECTIVE VIEW NIGHTTIME VIEW THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLIABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. U.L. LISTED A B C D E F G H I J custom alum. raceway(w/disconnect) building fascia low voltage wiring trim cap .080 aluminum back acrylic face weep holes mounting system L.E.D. circuit boards L.E.D. power supply 3”5” E I F D PC Letter / LEDs - Cross Section Detail J B H A G C Primary power (provided by others) Raceways to be painted SW 6627 Emberglow 2'-5 1/8" 29.12" 14'-5 1/2" 173.49" 7 7/8" 7.89" 1'-4 1/16" 16.08" 50'-5" frontage 18'-1" 18'-7"+/- to sidewalk 28.00" from soldier bricksto soft lighting (behind archway) 7'-0 1/2" 84.50" LA208532