Loading...
HomeMy WebLinkAboutLA208427 - Solar Bldg APPROVED - Orville Williamschen City of Lakeville BLDG Permit ApplicationRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov LH - email 11.22.2022 $201.00 Bldg and Elect Total $242.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: X X (solar) 200.00 1.00 201.00 V-B 2020 IRC-1 RS-3 DP Rooftop Solar (20 Panels) 11/22/22 :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ  6XEMHFW :LOOLDPVFKHQ5HVLGHQFH   *URYH7UDLO   /DNHYLOOH01  7R:KRP,W0D\&RQFHUQ  7KHIROORZLQJUHIHUHQFHVWKH:LOOLDPVFKHQ5HVLGHQFHLQ/DNHYLOOH01  ([LVWLQJURRIIUDPLQJ 5RRIV 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RFZLWK[DW´RFDERYH7KLV H[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUWDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDG PRGXOHVSOXVPRXQWLQJKDUGZDUH  SVIJURXQGVQRZORDG SVIURRIPDWHULDOV SVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV  ([SRVXUH&DWHJRU\%PSKZLQG VHF   7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG  7KDQN\RX  :HVWVKRUH'HVLJQ(QJLQHHUV  ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD  6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU      -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU  '0DLQOLQH'U  :HVWILHOG0$  'DWH1RYHPEHU 5HI  Provide copy of city approved plans on the job site for the inspector Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 11/18/2022dpfannenstein Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 11/18/2022dpfannenstein No less than 18 inch clear setback is required on both sides of a horizontal ridge, valley, or hip For each roof plane with a photo-voltaic array, a 36 inch wide pathway shall be provided from lowest roof edge to ridge on the same roof plane, on adjacent roof planes. One shall be on street/driveway side. 1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. Q.PEAK DUO BLK-G10+ 350-370 ENDURING HIGH PERFORMANCE PRELIMINARY DETAIL A 16 mm 8.5 mm21.25 mm 980 mm 1717 mm 4 × Mounting slots (DETAIL A) Frame 1045 mm 32 mm 8 × Drainage holes 368.5 mm EN 4 × Grounding points ø 4.5 mm Label ≥ 1150 mm ≥ 1150 mm 1002.5 mm EN RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 155 2520010 98 86 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²] α [% / K]+0.04 β [% / K]−0.27 γ [% / K]−0.34 NMOT [°C]43 ± 3 [V]1000 [A]20 C / TYPE 2 [Pa]3600 / 2660 −40 °C - +85 °C [Pa]5400 / 4000 350 355 360 365 370 [W]350 355 360 365 370 [A]10.97 11.00 11.04 11.07 11.10 [V]41.11 41.14 41.18 41.21 41.24 [A]10.37 10.43 10.49 10.56 10.62 [V]33.76 34.03 34.31 34.58 34.84 [%]≥ 19.5 ≥ 19.8 ≥ 20.1 ≥ 20.3 ≥ 20.6 [W]262.6 266.3 270.1 273.8 277.6 [A]8.84 8.87 8.89 8.92 8.95 [V]38.77 38.80 38.83 38.86 38.90 [A]8.14 8.20 8.26 8.31 8.37 [V]32.24 32.48 32.71 32.94 33.17 Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power dur- ing first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toler-ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G10+_350-370_2021-08_Rev01_ENPROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Class II Maximum Reverse Current IR Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 MECHANICAL SPECIFICATION Format 1717 mm × 1045 mm × 32 mm (including frame) Weight 19.9 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mmProtection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 1150 mm, (−) ≥ 1150 mm Connector Stäubli MC4; IP68 TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature QUALIFICATIONS AND CERTIFICATES Quality Controlled PV - TÜV Rheinland; IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. QCPV Certification ongoing. The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell/144 half-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-08-12 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell/120 half-cell PV modules only 60-cell/120 half-cell and 72-cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters INSTALLATION GUIDE PUB2016OCT28 SOLARMOUNT TILT LEGLOW & HIGH PROFILE 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D SOLARMOUNT TILT LEGLOW & HIGH PROFILE INSTALLATION GUIDE PAGE 11223344AABBCCDD11223344AABBCCDD11223344AABBCCDD1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D TILT LEG COMPONENTS A Properties Tilt Leg Strut Channel Square Tilt Leg Tube Units Area 0.515 0.4884 in2 Weight 0.57 0.56 plf Width 1.625 1.82 in Height 1.625 1.82 in Section Modulus (X-axis) 0.236 0.275 in3 Section Modulus (Y-axis)0.261 0.275 in3 Moment of Inertia (X-axis)0.201 0.2498 in4 Moment of Inertia (Y-axis)0.213 0.2498 in4 Radius of Gyration (X-axis)0.625 0.7152 in TILT LEG LENGTHS Total Adjustable Lengths Square Tube Strut 8" to 12"8"8" 18" to 30"18"18" 26" to 44"26"26" 40" to 72"40"40" 1 5/8" 1 13/16" 3/8" DIA. 3/8-16 X 3" HEX BOLT 3/8 X 1-1/2" X 1/8" HD FENDER WASHER L-FEET NOT INCLUDED IN LEG KITS 3/8-16 SS FLANGE NUT LEG STRUT LEG TUBESTRUT NUT 3/8" BOLT FENDER WASHER 3/8-16 X 1-1/4" SS HEX BOLT 3/8 x 1-1/2" x 1/8" HD FENDER WASHER 3/8-16 STRUT NUT 1" 1" 3/8" DIA. 1/16" 1/16"STRUT LENGTHSSQUARE TUBE LENGTHSWrenches and Torque Wrench Size Recommended Torque (ft-lbs) 3/8" Hardware 9/16"*30 w/Anti-Seize SOLARMOUNT TILT LEGLOW & HIGH PROFILE INSTALLATION GUIDE PAGE ACCEPTABLE APPLICATIONS B For more information on module placement please refer to the SOLARMOUNT installation guide. Remember to comply with module manufacturer clamping requirements A vertical leg orientation is acceptable. but DO NOT allow the bottom of the tilt legs for any application to be angled inboard towards the front of the array. PREFERRED TILT LEG ORIENTATION ACCEPTABLE TILT LEG ORIENTATION B 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D A A SOLARMOUNT TILT LEGLOW PROFILE INSTALLATION GUIDE PAGE TILT LEG GEOMETRY / ANGLE C North/south distance along the attachement surface (B) can be obtained using Unirac's U-Builder design & layout tool: http://design.unirac.com/tool/project_info/solarmount_2/ It is approximately equal to the distance up the module from bottom to the upper rail (A). NOTE: If you need to install the lower rail further above the bottom edge of the module, add a standoff under the front attachment to increase the height off the surface. For more information on module placement please refer to the SOLARMOUNT installation guide. Remember to comply with module manufacturer clamping requirements 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D B A A B NOTE: Experienced installers have been very successful with SOLARMOUNT Tilt by utilizing an easily made brace during installation. The brace is comprised of a beam (supplied by others such as a piece of strut, but could also be a piece of SOLARMOUNT rail) and four (4) L-feet. The purpose of the brace is to temporarily, but firmly, position rails perpendicular to module frame and parallel to each other at the desired tilt angle. Once modules have been properly fastened to the SOLARMOUNT rail top slot, the braces can be removed. This saves time by keeping rails positioned correctly as module installation begins. SOLARMOUNT TILT LEGLOW PROFILE INSTALLATION GUIDE PAGE ROOF & RAIL ATTACHMENT D ATTACH L-FOOT: Attach L-Foot to roof attachment assembly ASSEMBLE TILT LEG: 1) Place fender washer on 3/8" bolt 2) Loosely start strut nut on bolt ASSEMBLE TILT LEG (CONT): 3) Slide strut into tube with nut positioned as shown 4) Tighten bolt at desired leg length ATTACH L-FEET - BOTTOM RAIL: Attach L-foot to the rail as show within picture and secure to L-foot already secure to roof attachment. ATTACH TILT LEG TO L-FOOT: Add L-foot to bottom hole in tube using fender washer and 3/8" bolt and flange nut to form rear attachment. TORQUE VALUE EXCEPTION: 3/8” nut to 15 ft-lbs w/Anti-Seize (Lower torque required to avoid crushing tube) ATTACH L-FOOT TO TOP RAIL: Attach L-foot to strut using short 3/8" bolt and nut. Attach upper rail to L-foot. TORQUE VALUE: 3/8” nut to 30 ft-lbs w/Anti-Seize Y 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D 1 A SOLARMOUNT TILT LEGLOW PROFILE INSTALLATION GUIDE PAGE ROOF & RAIL ATTACHMENT E ATTACH L-FOOT: Attach L-Foot to roof attachment assembly. ALTERNATE ATTACHMENT - L-FOOT TO RAIL: Drill 3/8" hole through rail for alternate attachment. TYPICAL ATTACHMENT - L-FOOT TO RAIL: Attach L-foot to the SM rail by sliding the head of the 3/8" bolt into the slot in the rail and then through the upper hole in the L-foot and then tighten the flange nut. 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D 1 1 2 2 3 3 4 4 A A B B C C D D CONNECT L-FOOT TO RAIL: Slide head of the 3/8" Bolt into rail slot and then through the upper hole in L-Foot and tighten with flange nut. TORQUE VALUE: 3/8” nut to 30 ft-lbs w/Anti-Seize CONNECT TILT LEG TO RAIL: Slide 3/8" Bolt into rail slot and attach to strut with flange nut. TORQUE VALUE: 3/8” nut to 30 ft-lbs w/Anti-Seize 1 1 2 2 3 3 4 4 A A B B C C D D EXPLODED ASSEMBLY VIEW: For Reference Only Y SOLARMOUNT TILT LEGHIGH PROFILE INSTALLATION GUIDE PAGE TILT LEG GEOMETRY / ANGLE F SM RAIL LENGTH (Example Spacing Values)A B 132" Rail 92"40" 168" Rail 118"50" SM HD RAIL LENGTH (Example Spacing Values)A B 144" Rail 101"43" 168" Rail 118"50" Approximate Leg Spacing for 4 Leg Supports A= 0.7 x Rail Length (N-S Leg Spacing) B= 0.3 x Rail Length (Rail Overhang) To determine which type of rail is required. Obtain a high profile tilt engineering report by submitting our eQuestionnaire. The service is free of charge. http://unirac.com/configurators/equestionnaire NOTE: DO NOT SPLICE RAILS ON HIGH PROFILE TILT APPLICATIONS For more information on module placement please refer to the SOLARMOUNT installation guide. Remember to comply with module manufacturer clamping requirements 1 1 2 2 3 3 4 4 A A B B C C D D A B A SOLARMOUNT TILT LEGHIGH PROFILE INSTALLATION GUIDE PAGE TILT LEG GEOMETRY / ANGLE G SM RAIL LENGTH (Example Spacing Values)A B C 132" Rail 52"60"20" 168" Rail 67"76"25" Approximate Leg Spacing for 4 Leg Supports A= 0.40 x Rail Length (N-S Leg Spacing) B= 0.45 x Rail Length (N-S Leg Spacing) C= 0.15 x Rail Length (Rail Overhang) SM HD RAIL LENGTH (Example Spacing Values)A B C 144" Rail 58"65"21" 168" Rail 67"76"25" 204" Rail 82"92"30" To determine which type of rail is required. Obtain a high profile tilt engineering report by submitting our eQuestionnaire. The service is free of charge. http://unirac.com/configurators/equestionnaire NOTE: DO NOT SPLICE RAILS ON HIGH PROFILE TILT APPLICATIONS For more information on module placement please refer to the SOLARMOUNT installation guide. Remember to comply with module manufacturer clamping requirements 1 1 2 2 3 3 4 4 A A B B C C D D B A B A C snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience SnapNrack Umbrella Sealing Technology • Innovative Flashing Elevates Protection. New fl ashing uses a fully formed raised cone to prevent any potential water from getting into penetration. Feel secure as the fl ashing is one piece and doesn’t rely on multiple parts sealing together. • Mechanical Design Creates a Lifelong Seal. Patented Umbrella technology utilizes unique Umbrella Washer to seal lag bolt, L Foot, and fl ashing and prevent any potential roof leaks. Technology passes UL 2582 Wind Driven Rain Test without a rubber seal, however rubber gasket is included for extra peace of mind. • Single Fastener Eliminates Extra Steps. Utilize one lag bolt with Umbrella Washer to secure the entire mount assembly and fl ashing. No longer necessary to attach a base, then a fl ashing, then a mount as all are secured in one step. • Single Tool Installation. SnapNrack was the fi rst in the industry to develop a complete system that only requires a single tool. That tradition is continued as a ½” socket is still the only tool necessary to secure the mount as well as all other parts of the system. snapnrack.com Featuring New Innovative Flashing Smaller 9”x12” size allows for easier insertion under shingles Alignment markers make it easy to locate pilot holes Rounded corners make for easier insertion & eliminate corner points from folding up Note: Flashing shown in yellow for illustration purposes only. © 2018 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com snapnrack.com Ultra Rail, UR-40 Rail System Spans Wind (mph) 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 Snow (psf)0 5 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 120 System Span Key 6 ft Spans 4 ft Spans 2 ft Spans This table was prepared in compliance with applicable engineering codes and standards. Values are based on the following: • ASCE 7-10 • Chapter 30 Wind Loads & Chapter 7 Snow Loads • Roof Slope: 7 - 27 deg • Roof Height: 0 - 30 ft • Exposure: B • Roof Zone: 1 • Module Orientation: Portrait • Module Type: 60 Cell Modules • Roof Type: Comp Industry Leading Spans for a Light Rail Solution Visit SnapNrack.com for detailed span tables and certifi cations. Certifi cations SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 for wind-driven rain. Raised Cone Flashing Single Lag Secures Mount to Roof Pre-assembled Ultra Rail L Foot & Clamp Pre-assembled Ultra Rail