Loading...
HomeMy WebLinkAboutLA208411 - Solar Electric ELECTRICAL PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only ___________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total DATE YOUR E-MAIL ADDRESS SITE ADDRESS TENANT SUITE NO. THE APPLIANT IS: RESIDENT OWNER CONTRACTOR RESIDENT OWNER NAME_________________________________________________________________________ ADDRESS______________________________________________________________________ CITY _____________________________ STATE_____________ ZIP _____________________ DAYTIME PHONE # WHERE YOU CAN BE REACHED ______________________________ CONTRACTOR Company name must be as appears on State License COMPANY NAME_______________________________________LICENSE #EA___________ ADDRESS_____________________________________________________________________ CITY _____________________________ STATE_____________ ZIP _____________________ OFFICE PHONE # ________________________ FAX #_______________________________ CONTACT NAME______________________________________ PHONE__________________ PERMIT TYPE SINGLE FAMILY TWO FAMILY TOWNHOUSE Meter Bank Single Meter MULTI-FAMILY COMMERCIAL / INDUSTRIAL MANUFACTURED HOME (Contractor Only) INSTITUTIONAL SWIMMING POOL UNDEFINED FIRE ALARM POWER SIGN OTHER (see description) Residential Addition/ Remodel Permits Available on-line TYPE OF WORK NEW MAINTENANCE/REPAIR ADDITION TENANT FINISH ALTER / REMODEL DEMOLITION Only Licensed Electrical Contractors can do work in a Townhouse that has meter bank instead of single meters attached to the units. Only Licensed Electrical Contractors can do work in Manufactured Home Parks. RESIDENTIAL FEES: New Construction: $135.00 + $1.00 State Surcharge (up to three trips) Repairs: + $1.00 State Surcharge (one trip) Additions, Remodel, Lower Level: $70.00 + $1.00 State Surcharge (two trips) COMMERCIAL FEES: Minimum of + $1.00 State Surcharge (one trip) JOB COST: $ Example: $12,000 Job Cost 1-1/2% of contract cost up to $10,000 $10,000.00 x 1.5% = $150.00 1% of cost above $10,000 plus surcharge + $ 2,000.00 x 1% = + 20.00 (Surcharge = Contract Cost x .0005) + $12,000 x.0005 = + 6.00 TOTAL = = $176.00 I hereby apply for an electrical permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Lakeville and with the Minnesota Electrical Act; that I understand this is not a permit but only an application for a permit and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of all work which requires review and approval of plans. NAME OF APPLICANT (Please Print) SIGNATURE OF APPLICANT: PLEASE NOTE: SEPARATE PERMITS ARE REQUIRED FOR ANY BUILDING, MECHANICAL & PLUMBING WORK www.lakevillemn.gov $40.00 $40.00 Submit to: permits@lakevillemn.gov FOR OFFICE USE ONLY: TYPE OF WORK INSPECTIONS NEW FINAL ADDITION FIRE ACCEPTANCE TEST ALTER/REMODEL IN FOOR HEAT ROUGH-IN SERVICE TRENCH PERMIT FEE PERMIT FEE: $ SURCHARGE: $ OTHER: $ TOTAL: $ PERMIT ISSUED BY: DATE: 1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. Q.PEAK DUO BLK-G10+ 350-370 ENDURING HIGH PERFORMANCE PRELIMINARY DETAIL A 16 mm 8.5 mm21.25 mm 980 mm 1717 mm 4 × Mounting slots (DETAIL A) Frame 1045 mm 32 mm 8 × Drainage holes 368.5 mm EN 4 × Grounding points ø 4.5 mm Label ≥ 1150 mm ≥ 1150 mm 1002.5 mm EN RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 155 2520010 98 86 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²] α [% / K]+0.04 β [% / K]−0.27 γ [% / K]−0.34 NMOT [°C]43 ± 3 [V]1000 [A]20 C / TYPE 2 [Pa]3600 / 2660 −40 °C - +85 °C [Pa]5400 / 4000 350 355 360 365 370 [W]350 355 360 365 370 [A]10.97 11.00 11.04 11.07 11.10 [V]41.11 41.14 41.18 41.21 41.24 [A]10.37 10.43 10.49 10.56 10.62 [V]33.76 34.03 34.31 34.58 34.84 [%]≥ 19.5 ≥ 19.8 ≥ 20.1 ≥ 20.3 ≥ 20.6 [W]262.6 266.3 270.1 273.8 277.6 [A]8.84 8.87 8.89 8.92 8.95 [V]38.77 38.80 38.83 38.86 38.90 [A]8.14 8.20 8.26 8.31 8.37 [V]32.24 32.48 32.71 32.94 33.17 Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power dur- ing first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toler-ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G10+_350-370_2021-08_Rev01_ENPROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Class II Maximum Reverse Current IR Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 MECHANICAL SPECIFICATION Format 1717 mm × 1045 mm × 32 mm (including frame) Weight 19.9 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mmProtection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 1150 mm, (−) ≥ 1150 mm Connector Stäubli MC4; IP68 TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature QUALIFICATIONS AND CERTIFICATES Quality Controlled PV - TÜV Rheinland; IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. QCPV Certification ongoing. The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell/144 half-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-08-12 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell/120 half-cell PV modules only 60-cell/120 half-cell and 72-cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters