Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA208675-APPROVED - Manikanta Valluru REVA Permit Pack
1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480COVER SHEETPV1GENERAL NOTESCODE AND STANDARDSSITE NOTES / OSHA REGULATION5. NO. OF SHINGLE LAYERS : 3+SOLAR CONTRACTOREQUIPMENT LOCATIONSAERIAL VIEWDESIGN CRITERIAWIND SPEED:115 mphGROUND SNOW LOAD:50 lb/ft²WIND EXPOSURE FACTOR:CSEISMIC DESIGN CATEGORY:BSITE SPECIFICATIONSCONSTRUCTION - V-BZONING: RESIDENTIALSHEET INDEXPV1 - COVER SHEETPV2 - SITE PLANPV3 - ROOF PLANPV4 - STRUCTURALPV5 - ELECTRICAL 3-LINE DIAGRAMPV6 - ELECTRICAL CALCULATIONSPV7 - WARNING LABELS AND LOCATIONS(ALL OTHER SHEETS AS REQUIRED)SS - PRODUCT SPEC. SHEETSUTILITY COMPANY:Dakota Electric AssociationPERMIT ISSUER:City of LakevillePROJECT INFORMATION:NUMBER OF STORIES:2CONDUIT RUN:InteriorECOBEE QTY:0LIGHT BULB QTY:0PV METER:Utility PV Meter RequiredROOF TYPE (1) INFORMATION:ROOF TYPE:Comp ShingleFRAMING TYPE:Manufactured TrussSHEATHING TYPE:OSBATTACHMENT:SFM Infinity Switchblade FlashkitRACKING:Unirac SFM Infinity @ 24" OC Portrait / 48" OC LandscapeNUMBER OF ATTACHMENTS:43ROOF TYPE (2) INFORMATION (IF APPLICABLE):*SEE PV4.2SCOPE OF WORKINSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANYNECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION.SYSTEM TO BE INSTALLED INFORMATION:DC SYSTEM SIZE:6.4 kW DCAC SYSTEM SIZE:4.64 kW ACMODULE TYPE: (16) REC Solar REC400AA PureINVERTER TYPE:Enphase IQ8PLUS-72-2-USMONITORING:Enphase IQ Combiner 4 X-IQ-AM1-240-4Sealed ForExisting Roof &Attachment OnlyI hereby certify that this plan, specification or report was prepared by me orunder my direct supervision and that I am a duly Licensed ProfessionalEngineer under the laws of the State of Minnesota.John A. Calvert, LicenseNo. 52823 Expiration Date: 30-June-202412/5/2022Digitally signed by John A. Calvert Date: 2022.12.05 09:06:23 -07'00' MSPACPVMDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACCB1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480SITE PLANPV2SCALE: 1/16" = 1'-0"MMSPACCBLCSUBPVTSMAIN SERVICE PANELUTILITY METERAC DISCONNECTCOMBINER BOXLOAD CENTERSUBPANELPV METERTRANSFER SWITCHJUNCTION BOXLEGENDFIRE SETBACKTRENCHINGPROPERTY LINEESSHUBRPOSUNPOWER ESSSUNPOWER HUB+REMOTE POWER OFFPV SYSTEM SPECIFICATIONSTOTAL NUMBER OF MODULES:16MODULE MAKE AND MODEL:REC Solar REC400AA PureMODULE WATTAGE:400W DCINVERTER MAKE AND MODEL:Enphase IQ8PLUS-72-2-USINVERTER TYPE: Microinverter (1 Inverter per PV Module)INVERTER CURRENT OUTPUT:1.21A ACINVERTER NOMINAL VOLTAGE: 240VINVERTER WATTAGE:290W ACFRONT OF HOME7680 205TH ST WAASealed ForExisting Roof &Attachment OnlyI hereby certify that this plan, specification or report was prepared by me orunder my direct supervision and that I am a duly Licensed ProfessionalEngineer under the laws of the State of Minnesota.John A. Calvert, LicenseNo. 52823 Expiration Date: 30-June-202412/5/2022 MSPACPVMDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACCB1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480ROOF PLANPV3SCALE: 1/8" = 1'-0"MMSPACCBLCSUBPVTSMAIN SERVICE PANELUTILITY METERAC DISCONNECTCOMBINER BOXLOAD CENTERSUBPANELPV METERTRANSFER SWITCHJUNCTION BOXLEGENDFIRE SETBACKTRENCHINGPROPERTY LINEESSHUBRPOSUNPOWER ESSSUNPOWER HUB+REMOTE POWER OFFPV SYSTEM SPECIFICATIONSTOTAL NUMBER OF MODULES:16MODULE MAKE AND MODEL:REC Solar REC400AA PureMODULE WATTAGE:400W DCINVERTER MAKE AND MODEL:Enphase IQ8PLUS-72-2-USINVERTER TYPE: Microinverter (1 Inverter per PV Module)INVERTER CURRENT OUTPUT:1.21A ACINVERTER NOMINAL VOLTAGE: 240VINVERTER WATTAGE:290W ACFRONT OF HOMEPOINT OF INTERCONNECTIONUNDERGROUND SERVICE LINEMP1# OF MODULES: 16AZIMUTH: 174PITCH: 26TSRF: 99%AREA: 755 ft.²1'-6"1'-6"3'AASealed ForExisting Roof &Attachment OnlyI hereby certify that this plan, specification or report was prepared by me orunder my direct supervision and that I am a duly Licensed ProfessionalEngineer under the laws of the State of Minnesota.John A. Calvert, LicenseNo. 52823 Expiration Date: 30-June-202412/5/2022Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/06/2022dpfannensteinNo less than 18 inch clearsetback is required on bothsides of a horizontal ridge,valley, or hipFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side. ATTACHMENT SPACING- SIDE VIEWDSCALE: 1/2" = 1'-0"BALANDSCAPEPORTRAITABMODULEWIDTHMODULEWIDTHPV MODULEROOF STRUCTURE26°PV MODULEUNIRAC SFM 2" MICRORAILUNIRAC SFM 6.5" SPLICEPV MODULEUNIRAC SFM 2" MICRORAIL"MAX.48" MAX.MAX."24" MAX.ATTACHMENT SPACING- FRONT VIEWCSCALE: 3/4" = 1'-0"LANDSCAPEPORTRAIT-RACKING ATTACHMENTS TO BE STAGGEREDBY SHIFTING EACH SUBSEQUENT ROW OFATTACHMENTS OVER ONE RAFTER.UNIRAC SFM 8"ATTACHED SPLICEBOTTOM STANDOFF DETAILBSCALE: 3" = 1'-0"MIDDLE/TOP STANDOFF DETAILASCALE: 3" = 1'-0"UNIRAC SFM INFINITYREC SOLAR REC400AA PUREPV MODULEUNIRAC SFM MICRORAIL/ SPLICE(E) ROOFSHEATHINGFLASHINGUNIRAC SFM SLIDER(1) 5/16" STAINLESS STEEL LAG BOLTWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER(E) BUILDING STRUCTURE212" MIN. EMBED.REC SOLAR REC400AA PUREPV MODULE(E) ROOFSHEATHINGFLASHINGUNIRAC SFM SLIDER ANDTRIMRAIL ROOF ATTACHMENT(1) 5/16" STAINLESS STEEL LAG BOLTWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER(E) BUILDING STRUCTURE212" MIN. EMBED.UNIRAC SFM TRIMRAIL1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480STRUCTURALPV4STRUCTURAL INFORMATION:ROOF TYPE (1):ROOF TYPE: Comp ShingleSHEATHING TYPE: OSBFRAMING TYPE: Manufactured TrussFRAMING SIZE: 2x4 @ 24" OCCEILING JOIST SIZE: 2x4 @ 24" OCATTACHMENT: SFM Infinity Switchblade FlashkitRACKING: Unirac SFM Infinity@ 24" OC Portrait / 48" OC LandscapeNUMBER OF ATTACHMENTS: 43PV MODULE COUNT: 16 ModulesTOTAL ARRAY AREA: 326.4 ft² (20.4ft²/panel)TOTAL ROOF AREA: 2987 ft²ARRAY/ROOF AREA: 10.9%ARRAY WEIGHT: 800 lbs (50 lbs/panel)DISTRIBUTED LOAD: 2.45 lbs/ft²POINT LOAD: 18.6 lbs/attachmentSTRUCTURAL NOTES:None*NOTE: LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARYBASED ON FIELD CONDITIONS. MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PERENGINEER OF RECORD SPECIFICATIONS.ASealed ForExisting Roof &Attachment OnlyI hereby certify that this plan, specification or report was prepared by me orunder my direct supervision and that I am a duly Licensed ProfessionalEngineer under the laws of the State of Minnesota.John A. Calvert, LicenseNo. 52823 Expiration Date: 30-June-202412/5/2022 UTILITY COMPANY:Dakota Electric AssociationPERMIT ISSUER: City of Lakeville120/240 VAC60HZ1 PHASETO UTILITYGRIDL2L1NELECTRICAL NOTES:DESIGNER NOTES:LOAD SIDE BREAKER IN MSP BEHIND METER PER 2020 NEC, THE AC DISCONNECT MUST REQUIRE A TOOL TO OPEN. USE A NUT AND BOLT TOFASTEN THE DISCONNECT COVER.UTILITY PVPRODUCTIONMETEREGCL1L2N15PV AC DISCONNECTNON-FUSEDLOCKABLE, VISIBLE OPEN30A, 240V, 2-POLEL1L2NEGC15(1) CIRCUIT OF8 MODULES(1) CIRCUIT OF8 MODULESJB-1L1L2EGCL1L2(N) 20A / 2PL1L2EGC12JBJB-1L1L2EGCL1L2(N) 20A / 2PL1L2EGC12EGCNG15A / 2PENVOY(16) REC Solar REC400AA PureUL 1703 COMPLIANT(16) Enphase IQ8PLUS-72-2-USUL 1741 COMPLIANTENPHASE IQ COMBINER 4X-IQ-AM1-240-4(SOLAR LOAD ONLY)3JB-1 EZ SOLARJUNCTION BOX4"x4"x4" PVCJUNCTION BOX(E) 200A / 2P(N) 30A / 2P(E) LOADS(E) GROUNDINGELECTRODE(S)L2L1NEGC(E) 225A MAIN SERVICE PANEL(E) 200A / 2P MAIN BREAKERNG15*PV BREAKER TO BE LOCATEDAT OPPOSITE END OF BUSSINGFROM MAIN BREAKERINTERCONNECTION NOTES705.12(B)(3) THE FOLLOWING METHOD(S) SHALL BE USED TODETERMINE THE RATINGS OF BUSBARS: (2) WHERE TWO SOURCES,ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWERSOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THATCONTAINS LOADS, THE SUM OF 125 PERCENT OF THEPOWER-SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OFTHE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOTEXCEED 12O PERCENT OF THE AMPACITY OF THE BUSBAR.(2) NEW 58" COPPER GROUNDROD, 8' LONG, SPACED MIN. 6'APART.GEC INSTALLED PER NEC250.64: 6 OR 4 AWG SOLIDCOPPER GEC PROTECTED BYRMC/PVC/EMT1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480ELECTRICALPV5A GROUNDING NOTES1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690.47] AND [NEC 250.50-60] SHALL BEPROVIDED. PER [NEC 690.47], THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BEUSED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, ORINADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BEUSED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP.2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEENTHE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIREPER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FORSPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64(C)].3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWGCOPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METALPARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46].5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42].6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF AMODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE.7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THEMANUFACTURER'S INSTALLATION INSTRUCTIONS.8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHENGROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS.9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISESEXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL.10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHENEXPOSED.11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE AMINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TODAMAGE).12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKEDGREEN IF 4 AWG OR LARGER).13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVEGROUNDED BUSHINGS AT BOTH ENDS.14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZEDACCORDING TO [NEC 250.166], MINIMUM 8 AWG WHEN INSULATED, 6 AWG WHEN EXPOSED TO DAMAGE.15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, ANDCONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH [NEC 250.134] OR [NEC 250.136(A)]REGARDLESS OF VOLTAGE.WIRING & CONDUIT NOTES1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITEAPPLICATIONS.2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USEPOLARIS BLOCK OR NEUTRAL BAR).3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVELIVE PARTS, MEYERS HUBS RECOMMENDED4. UV RESISTANT CABLE TIES (NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOFSURFACE IN ACCORDANCE WITH [NEC 110.2,110.3(A-B)].5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIREMANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS.6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED ANDIDENTIFIED AS PV WIRE, TYPE TC-ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES ASREQUIRED.7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8] FOR MULTIPLECONDUCTORS.8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHTSHALLBEINSTALLEDATLEAST7/8"ABOVETHEROOFSURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE310.15(B)(3)(A)],& [NEC 310.15(B)(3)(C)].9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND ULLISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARPEDGES.10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED,WET AND UV RESISTANT, RATED FOR 600V11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUNDMARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS.12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DCPOSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY)15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED:DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK)16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED,PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY* USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE** USE-2 IS AVAILABLE AS UV WHITE17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES.18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT,FMC, OR MC CABLE IFDC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTINGMEANS SHALL COMPLY WITH [NEC 690.13] AND [NEC 690.15].19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH [NEC230.6(4)] AND SECURED NO GREATER THAN 6' APART PER [NEC 330.30(B)].1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480ELEC CALCSPV6 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480LABELSPV7ADDITIONAL LABELS*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUALREPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTEDMAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINEDIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK.UTILITYMETERMAINSERVICE PANEL1623IF BREAKERIS USED4810OROR PLACARDSUBPANEL(IF INTERCONNECTIONIS MADE HERE)162349ACDISCONNECT1279OR PLACARDPV COMBINERBOX125811PVMETERLABELING NOTES1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACTREQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.2) LABELING REQUIREMENTS BASED ON THE 2017 & 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535.3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ.4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BEHANDWRITTEN [NEC 110.21]LABEL 1FOR PV SYSTEM DISCONNECTING MEANS WHERE THELINE AND LOAD TERMINALS MAY BE ENERGIZED IN THEOPEN POSITION.[2017 NEC 690.13(B)][2020 NEC 690.13(B)]LABEL 2SHALL BE MARKED AT AN ACCESSIBLE LOCATION ATTHE DISCONNECTING MEANS AS A POWER SOURCEAND WITH THE RATED AC OUTPUT CURRENT AND THENOMINAL OPERATING AC VOLTAGE.[2017 NEC 690.54][2020 NEC 690.54]LABEL 3IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABELANYWHERE THAT IS POWERED BY BOTH THE UTILITYAND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANELAND SUBPANELS.[2017 NEC 705.12(B)(3)][2020 NEC 705.12(B)(3)]LABEL 4APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENTTO THE BACK-FED BREAKER FROM THE POWERSOURCE.[2017 NEC 705.12(B)(2)(3)(b)][2020 NEC 705.12(B)(3)(2)]LABEL 5APPLY TO THE PV COMBINER BOX[2017 NEC 705.12(B)(2)(3)(c)][2020 NEC 705.12(B)(3)(3)]LABEL 6BUILDINGS WITH PV SYSTEMS SHALL HAVE APERMANENT LABEL LOCATED AT EACH SERVICEEQUIPMENT LOCATION TO WHICH THE PV SYSTEMSARE CONNECTED OR AT AN APPROVED READILYVISIBLE LOCATION AND SHALL INDICATE THE LOCATIONOF RAPID SHUTDOWN INITIATION DEVICES.[2017 NEC 690.56(C)(1)(a)][2020 NEC 690.56(C)]LABEL 7SIGN LOCATED AT RAPID SHUT DOWN DISCONNECTSWITCH[2017 NEC 690.56(C)(3)][2020 NEC 690.56(C)(2)]LABEL 8PERMANENT PLAQUE OR DIRECTORY DENOTING THELOCATION OF ALL ELECTRIC POWER SOURCEDISCONNECTING MEANS ON OR IN THE PREMISESSHALL BE INSTALLED AT EACH SERVICE EQUIPMENTLOCATION AND AT THE LOCATION(S) OF THE SYSTEMDISCONNECT(S) FOR ALL ELECTRIC POWERPRODUCTION SOURCES CAPABLE OF BEINGINTERCONNECTED.[2017 NEC 705.10][2020 NEC 705.10]LABEL 9PERMANENT PLAQUE OR DIRECTORY DENOTING THELOCATION OF ALL ELECTRIC POWER SOURCEDISCONNECTING MEANS ON OR IN THE PREMISESSHALL BE INSTALLED AT EACH SERVICE EQUIPMENTLOCATION AND AT THE LOCATION(S) OF THE SYSTEMDISCONNECT(S) FOR ALL ELECTRIC POWERPRODUCTION SOURCES CAPABLE OF BEINGINTERCONNECTED.[2017 NEC 705.10][2020 NEC 705.10]LABEL 10PERMANENT PLAQUE OR DIRECTORY TO BELOCATED AT MAIN SERVICE EQUIPMENT DENOTINGTHE LOCATION OF THE RAPID SHUTDOWN SYSTEMDISCONNECTING MEANS IF SOLAR ARRAY RAPIDSHUTDOWN DISCONNECTING SWITCH IS NOTGROUPED AND WITHIN LINE OF SITE OF MAINSERVICE DISCONNECTING MEANS.[2017 NEC 705.10 AND 690.56(C)(1)(a)][2020 NEC 705.10 AND 690.56(C)]LABEL 11PERMANENT PLAQUE OR DIRECTORY TO BELOCATED AT AC COMBINER PANEL.[2017 NEC 110.21(B)][2020 NEC 110.21(B)]ELECTRIC SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNING!PHOTOVOLTAIC SYSTEMAC DISCONNECT!!240 VNOMINAL OPERATING AC VOLTAGERATED AC OUTPUT CURRENT 19.36 ADUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEMWARNING!POWER SOURCE OUTPUT CONNECTIONDO NOT RELOCATETHIS OVERCURRENTDEVICEWARNING!THIS EQUIPMENT FED BY MULTIPLESOURCES. TOTAL RATING OF ALLOVERCURRENT DEVICES, EXCLUDINGMAIN SUPPLY OVERCURRENTDEVICE, SHALL NOT EXCEEDAMPACITY OF BUSBAR.WARNING!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMMAIN DISTRIBUTION UTILITY DISCONNECT(S)POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM A ROOF MOUNTED SOLAR ARRAY WITHA RAPID SHUTDOWN DISCONNECTING MEANSGROUPED AND LABELED WITHIN LINE OF SITEAND 10 FT OF THIS LOCATIONWARNING!POWER TO THIS BUILDING IS ALSOSUPPLIED FROM MAIN DISTRIBUTIONUTILITY DISCONNECT LOCATEDWARNING!POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM A ROOF MOUNTED SOLAR ARRAY. SOLARARRAY RAPID SHUTDOWN DISCONNECT ISLOCATED OUTSIDE NEXT TO THE UTILITY METER.WARNING!PHOTOVOLTAIC SYSTEMCOMBINER PANELDO NOT ADD LOADSWARNING!STANDARD LABELS MSPCBACM1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Manikanta Valluru7680 205th St WLakeville, Minnesota 55044AC SYSTEM SIZE: 4.64 kW ACDC SYSTEM SIZE: 6.4 kW DCDRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:Erik ArmstrongDecember 4, 2022652701ACERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS800-377-4480PLACARDPV8DIRECTORY PLACARD NOTES[NEC 705.10] A PERMANENT PLAQUE OR DIRECTORY DENOTING THELOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ONOR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENTLOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FORALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEINGINTERCONNECTED. THE MARKING SHALL COMPLY WITH [110.21(B)]. 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSSIQ8 and IQ8+ MicroinvertersOur newest IQ8 Microinverters are the industry’s first microgrid-forming, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down*• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesMicrogrid-forming• Complies with the latest advanced grid support**• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) requirements© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change.IQ8SP-DS-0002-01-EN-US-2022-03-17* Only when installed with IQ System Controller 2, meets UL 1741. ** IQ8 and IQ8Plus supports split phase, 240V installations only.DATA SHEET(1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8 and IQ8+ MicroinvertersINPUT DATA (DC) IQ8-60-2-US IQ8PLUS-72-2-USCommonly used module pairings1W235 – 350 235 – 440Module compatibility 60-cell/120 half-cell60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cellMPPT voltage rangeV27 – 37 29 – 45Operating rangeV25 – 48 25 – 58Min/max start voltageV30 / 48 30 / 58Max input DC voltageV50 60Max DC current2 [module Isc]A15Overvoltage class DC portIIDC port backfeed currentmA0PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ8-60-2-US IQ8PLUS-72-2-USPeak output powerVA245 300Max continuous output powerVA240 290Nominal (L-L) voltage/range3V240 / 211 – 264Max continuous output currentA1.0 1.21Nominal frequencyHz60Extended frequency rangeHz50 – 68AC short circuit fault current over 3 cycles Arms2Max units per 20 A (L-L) branch circuit416 13Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed currentmA30Power factor setting1.0Grid-tied power factor (adjustable) 0.85 leading – 0.85 laggingPeak efficiency%97.5 97.6CEC weighted efficiency%97 97Night-time power consumptionmW60MECHANICAL DATAAmbient temperature range -40ºC to +60ºC (-40ºF to +140ºF)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (HxWxD) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesPollution degreePD3Enclosure Class II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure rating NEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8SP-DS-0002-01-EN-US-2022-03-17IQ8PLUS-72-2-US235 – 44060-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell29 – 4525 – 5830 / 5860IQ8PLUS-72-2-US3002901.211397.697 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.SHEET NAME:PAGE NUMBER:REVISION:0CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSSS 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSSrec Alphơ®pure Series ơexperienceperformancewp410222w M2Product SpecificationsELIGIBLELEAD-FREErohs cOMPLIANTCOMPACT PANEL SizeRef: PM-DS-12-06-Rev- E 11.21GR GR GR GRGR 1821±2.5 [71.7±0.1]901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3]1200 [47.2]30 [1.2]22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2[0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02]6.0±0.2[0.24±0.01]28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] 153.7 [6.05]153.7 [6.05]www.recgroup.comGENERAL DATACell type:132 half-cut REC heterojunction cells with lead-free, gapless technology, 6 strings of 22 cells in seriesGlass:3.2 mm solar glass with anti-reflective surface treatmentin accordance with EN 12150Backsheet: Highly resistant polymer (black)Frame: Anodized aluminum (black)Junction box:3-part, 3 bypass diodes, lead-freeIP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (4 mm²)in accordance with IEC 62852, IP68 only when connectedCable:4 mm² solar cable, 1.1 m + 1.2 min accordance with EN 50618Dimensions: 1821 x 1016 x 30 mm (1.85 m2)Weight: 20.5 kgOrigin: Made in SingaporeSpecifications subject to change without notice.Measurements in mm [in]LOW LIGHT BEHAVIOURTypical low irradiance performance of module at STC:WARRANTYStandardREC ProTrustInstalled by an REC Certified Solar ProfessionalNo Yes YesSystem Size All ≤25 kW25-500 kWProduct Warranty (yrs)2025 25Power Warranty (yrs)2525 25Labor Warranty (yrs)025 10Power in Year 1 98% 98% 98%Annual Degradation 0.25% 0.25% 0.25%Power in Year 25 92% 92% 92%See warranty documents for details. Conditions apply Irradiance (W/m²)Rel. Efficiency (%)TEMPERATURE RATINGS*Nominal Module Operating Temperature: 44°C (±2°C)Temperature coefficient of PMAX:-0.26 %/°CTemperature coefficient of VOC:-0.24 %/°CTemperature coefficient of ISC:0.04 %/°C*The temperature coefficients stated are linear valuesCERTIFICATIONSIEC 61215:2016, IEC 61730:2016, UL 61730IEC 62804 PIDIEC 61701 Salt MistIEC 62716 Ammonia ResistanceISO 11925-2 Ignitability (Class E)IEC 62782 Dynamic Mechanical LoadIEC 61215-2:2016 Hailstone (35mm)IEC 62321 Lead-freeacc. to RoHS EU 863/2015ISO 14001, ISO 9001, IEC 45001, IEC 62941DELIVERY INFORMATIONPanels per pallet: 33Panels per 40 ft GP/high cube container: 792 (24 pallets)Panels per 13.6 m truck: 924 (28 pallets)Panels per 53 ft truck: 891 (27 pallets)MAXIMUM RATINGSOperational temperature: -40 ... +85°CMaximum system voltage: 1000 VMaximum test load (front): + 7000 Pa (713 kg/m²)*Maximum test load (rear): - 4000 Pa (407 kg/m²)*Max series fuse rating: 25 AMax reverse current: 25 A* See installation manual for mounting instructions.Design load = Test load / 1.5 (safety factor) STC NMOTFounded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific.859095100105 200100 300 400 500 600 700 800 900 1000REC Alpha Pure Series Product SPECIFICATIONStake-e-way WEEE-compliant recycling schemeLead-FreeELECTRICAL DATA Product Code*: RECxxxAA PurePower Output - PMAX (Wp) 385 390 395 400 405 410Watt Class Sorting - (W) 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 42.7Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 9.61Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 49.0Short Circuit Current - ISC (A) 10.18 10.19 10.20 10.25 10.30 10.35Power Density (W/m2) 208 211 214 216 219 222Panel Efficiency (%) 20.8 21.1 21.4 21.6 21.9 22.2Power Output - PMAX (Wp)293 297 301 305 309 312Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 40.2Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 7.76Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 46.2Short Circuit Current - ISC (A) 8.16 8.20 8.24 8.28 8.32 8.36Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C), based on a production spread with a tolerance of PMAX, VOC & ISC±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 20°C, windspeed 1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.SHEET NAME:PAGE NUMBER:REVISION:0CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSSS 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.SHEET NAME:PAGE NUMBER:REVISION:0CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSSS15-20 in-lbsUL Standard 1741, Nema Type 3RUL Standard 1741, Nema Type 3R 1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.SHEET NAME:PAGE NUMBER:REVISION:0CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSSS SFMSUNFRAMEMICRORAIL™PAGESYSTEM BONDING & GROUNDINGSE-W BONDING PATH: (:PRGXOHWRPRGXOHERQGLQJLVDFFRPSOLVKHGZLWKSUHLQVWDOOHGERQGLQJSLQVZKLFKHQJDJHRQWKHVHFXUHVLGHRIWKH0LFURUDLO70DQGVSOLFHTRIMRAIL BONDING PATH:7ULPUDLOWRPRGXOHERQGLQJLVDFFRPSOLVKHGZLWKERQGLQJFODPSZLWKLQWHJUDOERQGLQJSLQDQGERQGLQJ7EROW(refer also to alternate method )N-S BONDING PATH:16PRGXOHWRPRGXOHERQGLQJLVDFFRPSOLVKHGZLWKERQGLQJFODPSZLWKLQWHJUDOERQGLQJSLQV(refer also to alternate method )System bonding is accomplished through modules. System grounding accomplished by attaching DJURXQGOXJWRDQ\PRGXOHDWDORFDWLRQRQWKHPRGXOHVSHFLʳHGE\WKHPRGXOHPDQXIDFWXUHULUG DETAIL & TORQUE INFOIlsco Lay-In Lug (GBL-4DBT)•PRXQWLQJKDUGZDUH•7RUTXH IWOE•$:*6ROLGRU6WUDQGHGLUG DETAIL & TORQUE INFOIlsco Flange Lug(SGB-4)•ȧPRXQWLQJKDUGZDUH•7RUTXH LQOE•$:*6ROLGRU6WUDQGHGLUG DETAIL & TORQUE INFOWiley WEEBLug (6.7)•ȧPRXQWLQJKDUGZDUH•7RUTXH IWOE•$:*6ROLGRU6WUDQGHGNOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSIONTERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs8 AWG: 25 in-lbs10-14 AWG: 20 in-lbsTERMINAL TORQUE,Install Conductor and torque to the following: 6-14 AWG: 7ft-lbsTERMINAL TORQUE,Install Conductor and torque to the following: 4-14 AWG: 35in-lbsWEEBLUGSingle Use OnlyStar Washer isSingle Use OnlyÑ$OWHUQDWHPHWKRG$OWHUQDWHPHWKRGINSTALLATION GUIDE1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMHEREIN CONTAINED SHALL NOT BEEXCEPT BLUE RAVEN SOLAR NORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDWITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:CERTIFIEDScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700CONFIDENTIAL- THE INFORMATIONUSED FOR THE BENEFIT OF ANYONESHALL IT BE DISCLOSED IN WHOLE ORUSE OF THE RESPECTIVE EQUIPMENT,DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----NABCEPPV INSTALLATIONPROFESSIONALSPEC SHEETSS SFMSUNFRAMEMICRORAIL™PAGEUL CODE COMPLIANCE NOTES TSYSTEM LEVEL FIRE CLASSIFICATION7KHV\VWHPʳUHFODVVUDWLQJUHTXLUHVLQVWDOODWLRQLQWKHPDQQHUVSHFLʳHGLQWKH681)5$0(0,&525$,/6)0,QVWDOODWLRQ*XLGH6)0KDVEHHQFODVVLʳHGWRWKHV\VWHPOHYHOʳUHSRUWLRQRI8/7KLV8/FODVVLʳFDWLRQKDVEHHQLQFRUSRUDWHGLQWRWKH8/SURGXFWFHUWLʳFDWLRQ6)0KDVDFKLHYHG&ODVV$% &V\VWHPOHYHOSHUIRUPDQFHIRUORZVORSH VWHHSVORSHGURRIVZKHQXVHGLQFRQMXQFWLRQZLWKW\SHDQGW\SHPRGXOHV&ODVV$% &V\VWHPOHYHOʳUHUL2703 TEST MODULES6HHSDJHV9DQG:IRUDOLVWRIPRGXOHVWKDWZHUHHOHFWULFDOO\DQGPHFKDQLFDOO\WHVWHGRUTXDOLʳHGZLWKWKH681)5$0(0,&525$,/6)0FRPSRQHQWVRXWOLQHGZLWKLQWKLV,QVWDOODWLRQ*XLGH•0D[LPXP$UHDRI0RGXOH VTIW•8/'HVLJQ/RDG5DWLQJVD 'RZQZDUG3UHVVXUHȡ36)3DE 8SZDUG3UHVVXUHȡ36)3DF 'RZQ6ORSH/RDGȡ36)3D•7HVWHG/RDGVD 'RZQZDUG3UHVVXUHȡ36)3DE 8SZDUG3UHVVXUHȡ36)3DF 'RZQ6ORSH/RDGȡ36)3D•0D[LPXP6SDQ IW•8VHZLWKDPD[LPXPRYHUFXUUHQWSURWHFWLRQGHYLFH2&3'RI$•6\VWHPFRQIRUPVWR8/6WGFHUWLʳHGWR/75$(•5DWHGIRUDGHVLJQORDGRI3D3DZLWKLQFKVSDQ•39PRGXOHVPD\KDYHDUHGXFHGORDGUDWLQJLQGHSHQGHQWRIWKH6)0ORDGUDWLQJ3OHDVHFRQVXOWWKH39PRGXOHPDQXIDFWXUHU VLQVWDOODWLRQJXLGHIRUPRUHLQIRUPDWLRQ•'RZQ6ORSHGHVLJQORDGUDWLQJRI36)3DIRUPRGXOHDUHDVRIVTIWRUOHVVModule Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation RequiredType 1 and Type 26WHHS6ORSH /RZ6ORSH &ODVV$% & (DVW:HVW /DQGVFDSH253RUWUDLWNone RequiredSHUIRUPDQFHLVLQKHUHQWLQWKH6)0GHVLJQDQGQRDGGLWLRQDOPLWLJDWLRQPHDVXUHVDUHUHTXLUHG7KHʳUHFODVVLʳFDWLRQUDWLQJLVYDOLGIRUDQ\URRISLWFK7KHUHLVQRUHTXLUHGPLQLPXPRUPD[LPXPKHLJKWOLPLWDWLRQDERYHWKHURRIGHFNWRPDLQWDLQWKH&ODVV$% &ʳUHUDWLQJIRU6)0681)5$0(0,&525$,/TM FRPSRQHQWVVKDOOEHPRXQWHGRYHUDʳUHUHVLVWDQWURRIFRYHULQJUDWHGIRUWKHDSSOLFDWLRQINSTALLATION GUIDE1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS SFMSUNFRAMEMICRORAIL™PAGETESTED / CERTIFIED MODULE LIST VAleo P-Series$VWURQHUJ\&+603&+603+9&+600&+600+9&+600%/%)+)&+600+&Auxin$;107$;137$;107 $;137$[LWHF$;,EODFNSUHPLXPPP$;,SRZHUPP$;,SRZHUPP$;,SUHPLXPPP$;,SUHPLXPPP$SWRV'1$%)0)'1$%)0)%RYLHW%90%90%<' 3. 0+.6HULHVCanadian Solar&6+.8<06&6./8&6.0%$*&6.063&6106&680%$*&68063&6:&6$0&6.8&6.03&6.06&6303&6803&690&6;3&HQWURVRODU$PHULFDC-Series & E-Series&HUWDLQ7HHG&7[[0[[&7[[3[[&7[[[0[[&7[[[0&7[[[0[[&7[[[+&'HKXL '+0Manufacture Module Model / SeriesEco Solargy Orion 1000 & Apollo 1000ET Solar(70%+[[[7:)UHH9ROWMono PERCGCL GCL-P6 & GCL-M6 Series+DQVRO7'$17'$18%$18'$1+HOLHQH 0030 36HULHV+76RODU+701'9)+703+\XQGDL.*0*7*5,5*7,0,+, .,6HULHV+L$6[[[+*,7(. L7L7+( L76(6HULHVJapan Solar JPS-60 & JPS-72 SeriesJA Solar-$3[[[-$0[[[6,-$0.[[[-$3N[[[%%-$36<<[[[==-$3N[[[%%-$36<<[[[==-$0N[[[==-$06<<[[[==-$0N[[[==-$06<<[[[==L<<LL==6&35%3+L7,%0:05-LQNR-.0 -.066HULHV(DJOH-.0[[[0-.0[[[0+/9.\RFHUD .86HULHV/*(OHFWURQLFVLGxxxN2T-A4/*[[[$&(&(.1&1.171:4&4.6&6:$LGxxxN2T-B5/*[[[1.%/*[[[$&0&0.1&1.4&4.4$&4$.$/*[[[1&1.171:(/*[[[1&1.1:6&6:*LGxxxN2T-J5/*[[[1.1:171://*[[[1&4&4.1/*[[[1&1.1:4&4.9LONGi/5+,%+,++3%+3+[[[0/5+,++3+[[[0/5%3+%'+,%'[[[0PP/5%.3(+3%+3+[[[0PP/5%.3(3%3+[[[0PP/5%3+%'+,%'[[[0PP/5+9%.3(3+3%+3+[[[0PP/5%.+93(3%3+[[[0PPMission Solar Energy MSE Series0LWVXELVKLMJE & MLE Series1HR6RODU3RZHU&R '0 '36HULHVManufacture Module Model / SeriesManufacture Module Model / Seriesȫ 8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ȫ ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,'ȫ 6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,'ȫ 3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDW8QLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0ȫ 6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJH/IRUIXUWKHULQIRUPDWLRQINSTALLATION GUIDE1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS SFMSUNFRAMEMICRORAIL™PAGETESTED / CERTIFIED MODULE LIST WPanasonic9%+1[[[6$ 6$9%+1[[[6$ 6$9%+1[[[6$(* 6$(9%+1[[[.$ .$ .$9%+1[[[=$9%+1[[[=$9%+1[[[=$9%+1[[[=$Peimar6*[[[0)%%)Phono Solar3636Prism Solar P72 Series4&HOOV3OXV3UR3HDN******3UR3HDN/*/*/*/*/*43($.'82%/.*43($.'82%/.*7643($.'82%/.*43($.'82/*%))43($.'82%/.0/*43($.'82;/***43($.'82%/.0/*43($.'82;/*FGREC$OSKD%ODFN3XUH13HDN%ODFN13HDN%ODFN3($.(QHUJ\6HULHV3($.(QHUJ\%/.6HULHV3($.(QHUJ\6HULHVManufacture Module Model / Series5(&FRQW7ZLQ3HDN6HULHV7ZLQ3HDN6HULHV7ZLQ3HDN%/.6HULHV7ZLQ3HDN60;97ZLQ3HDN6HULHVPP73%ODFNRenesola9LWUXV6HULHV 6HULHVRisen5600'*0560S-Energy61 616HULHVPPSeraphim SEG-6 & SRP-6 SeriesSharp NU-SA & NU-SC Series6LOIDE6/$6/*%&6HULHV 6,/[[[%/1/17+/0/%.1;18+&Solaria3RZHU;7[[[5$&3'%'3RZHU;7[[[&3'3RZHU;7[[[530$&SolarWorld6XQPRGXOH3URWHFWSunmodule PlusSonali SS 230 - 2656XQWHFKSTP6XQLYD 096HULHV 2SWLPXV6HULHV6XQ(GLVRQ)OH[WURQLFV )6HULHV56HULHV )/(;);66HULHVSunPower;6HULHV(6HULHV 36HULHVTalesun7373737373+LSRU06PDUWTesla6&6&%6&%6&%TxxxSTrina3$3''''(''3(3'3('''('('(3(+Upsolar830[[[3%830[[[0%URE'0[[[+$'0.[[[+$)$.[[[&*(*)$0[[[(*%%)$0[[[(*%%9LNUDP(OGRUD6ROLYRSomeraWaaree AC & Adiya SeriesWinaico WST & WSP SeriesYingli YGE & YLM SeriesZN Shine=;0Manufacture Module Model / SeriesManufacture Module Model / Seriesȫ 8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ȫ ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,'ȫ 6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,'ȫ 3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDW8QLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0ȫ 6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJH/IRUIXUWKHULQIRUPDWLRQINSTALLATION GUIDE1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS AUTHORIZATION TO MARKApplicant:Manufacturer:Address:Address:Country: Country:2Standard(s):Product:Brand Name:Models:Unirac, Inc1411 Broadway Blvd NE Albuquerque, NM 87102USAParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Intertek Testing Services NA, Inc., Lake Forest, CAControl Number:5003705Authorized by: for L. Matthew Snyder, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:29May2019]PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020]Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2021NOV29Unirac SFMUniracThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Coveredsection when made in accordance with the conditions set forth in the Certification Agreement andListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of theListingReport.Thisdocument is the property of Intertek Testing Services and is not transferable. The certification mark(s) maybeappliedonly at the location of the Party Authorized To Apply Mark.nc., Lake Forest, CAforLMatthew SnyderCertificationPage 1 of 4 ATM for Report 102393982LAX-002 ATM Issued: 7-Jan-2022ED 16.3.15 (16-Oct-2021) MandatoryAUTHORIZATION TO MARKApplicant:Manufacturer:Address:Address:Country: Country:223524 3Standard(s):Product:Brand Name:Models:Unirac, Inc1411 Broadway Blvd NE Albuquerque, NM 87102USAParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Intertek Testing Services NA, Inc., Lake Forest, CAControl Number:5014989Authorized by: for L. Matthew Snyder, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:29May2019]PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020]Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2021NOV29UniracUnirac SFMThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Coveredsection when made in accordance with the conditions set forth in the Certification Agreement andListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of theListingReport.Thisdocument is the property of Intertek Testing Services and is not transferable. The certification mark(s) maybeappliedonly at the location of the Party Authorized To Apply Mark.LakeForest,CAMatthew SnyderCertificationManPage 2 of 4 ATM for Report 102393982LAX-002 ATM Issued: 7-Jan-2022ED 16.3.15 (16-Oct-2021) Mandatory1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS AUTHORIZATION TO MARKApplicant:Manufacturer:Address:Address:Country: Country:4Standard(s):Product:Brand Name:Models:Unirac, Inc1411 Broadway Blvd NE Albuquerque, NM 87102USAParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Intertek Testing Services NA, Inc., Lake Forest, CAControl Number:5019851Authorized by: for L. Matthew Snyder, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:29May2019]PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020]Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2021NOV29UniracUnirac SFMThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Coveredsection when made in accordance with the conditions set forth in the Certification Agreement andListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of theListingReport.Thisdocument is the property of Intertek Testing Services and is not transferable. The certification mark(s) maybeappliedonly at the location of the Party Authorized To Apply Mark.Inc., Lake Forest, CAfor L Matthew Snyder CertificationPage 3 of 4 ATM for Report 102393982LAX-002 ATM Issued: 7-Jan-2022ED 16.3.15 (16-Oct-2021) MandatoryAUTHORIZATION TO MARKApplicant:Manufacturer:Address:Address:Country: Country:5Standard(s):Product:Brand Name:Models:Unirac, Inc1411 Broadway Blvd NE Albuquerque, NM 87102USAParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Intertek Testing Services NA, Inc., Lake Forest, CAControl Number:5021866Authorized by: for L. Matthew Snyder, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.Unirac SFMThis Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:29May2019]PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020]Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2021NOV29UniracThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Coveredsection when made in accordance with the conditions set forth in the Certification Agreement andListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of theListingReport.Thisdocument is the property of Intertek Testing Services and is not transferable. The certification mark(s) maybeappliedonly at the location of the Party Authorized To Apply Mark.,Lake Forest, CAL. Matthew Snyder, CertificationMaPage 4 of 4 ATM for Report 102393982LAX-002 ATM Issued: 7-Jan-2022ED 16.3.15 (16-Oct-2021) Mandatory1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS Listing Constructional Data Report (CDR)Report Number102393982LAX-002Original 11-Apr-2016 Revised: 2-Jan-2022Standard(s)Applicant Manufacturer 2Address AddressCountry CountryContact ContactPhone PhoneFAX FAXEmail EmailManufacturer 3Manufacturer 4Address AddressCountry CountryContact ContactPhone PhoneFAX FAXEmail EmailManufacturer 5AddressCountryContactPhoneFAX505-462-2190505-843-1418NAklaus.nicolaedis@unirac.com toddg@unirac.com1411 Broadway Blvd NE Albuquerque, NM 87102USAKlaus Nicolaedis Todd Ganshaw1.0 Reference and AddressMounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:29May2019]PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020]Unirac, IncPage 1 of 136 Listing Constructional Data Report (CDR)Report Number102393982LAX-002Original 11-Apr-2016 Revised: 2-Jan-20221.0 Reference and AddressEmailPage 2 of 1361403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS Report No. 102393982LAX-002Unirac, IncPage 4 of 136Issued: 11-Apr-2016Revised: 2-Jan-20222.0 Product DescriptionModelsModel SimilarityOther RatingsRatingsFuse Rating: 30AModule Orientation: Portrait or LandscapeMaximum Module Size: 17.98 ft²UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-SlopeTested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down SlopeTrina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical LoadingIncreased size ML test:Maximum Module Size: 22.3 ft²UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope LG355S2W-A5used for Mechanical Loading test.Mounting configuration: Four mountings on each long side of panel with the longest span of 24"UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5,LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test.Mounting configuration: Six mountings for two modules used with the maximum span of 74.5"IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 50psf/2400Pa UpliftMechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 Certifications, & Increase SFM System UL2703 Module Size:Maximum Module Size: 27.76 ft²UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-SlopeJinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24"Mamzimum module size: 21.86 ft2IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical LoadingFire Class Resistance Rating:- Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules.This system was evaluated with a 5” gap between the bottom of the module and the roof’ssurfaceSee section 7.0 illustractions # 1, 1a, 1b, and 1c for a complete list of PV modules evaluated with these racking systemsUnirac SFMNANAED 16.3.15 (16-Oct-2021) MandatoryReport No. 102393982LAX-002Unirac, IncPage 3 of 136Issued: 11-Apr-2016Revised: 2-Jan-2022Product Brand nameThe product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground.The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame (at bottom flange) to contact the metal, creating a bonded connection from module to module.The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the revision in effect in the jurisdiction in which the project resides. Any local electrical codes must be adhered in addition to the national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable.2.0 Product DescriptionPhotovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2021NOV29UniracDescriptionED 16.3.15 (16-Oct-2021) Mandatory1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS Report No. 102393982LAX-002Unirac, IncPage 42 of 136Issued: 11-Apr-2016Revised: 2-Jan-20227.0 IllustrationsIllustration 1 - Approved PV ModulesED 16.3.15 (16-Oct-2021) MandatoryReport No. 102393982LAX-002Unirac, IncPage 43 of 136Issued: 11-Apr-2016Revised: 2-Jan-20227.0 IllustrationsIllustration 1a - Approved PV Modules ContinueED 16.3.15 (16-Oct-2021) Mandatory1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS Report No. 102393982LAX-002Unirac, IncPage 44 of 136Issued: 11-Apr-2016Revised: 2-Jan-20227.0 IllustrationsIllustration 1b - Approved PV Modules ContinueED 16.3.15 (16-Oct-2021) Mandatory1403 N. Research WayOrem, UT 84097800.377.4480WWW.BLUERAVENSOLAR.COMCONFIDENTIAL- THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NORSHALL IT BE DISCLOSED IN WHOLE ORIN PART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION, EXCEPTIN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.DRAWING BY:PLOT DATE:PROJECT NUMBER:SHEET NAME:PAGE NUMBER:REVISION:----CERTIFIEDNABCEPPV INSTALLATIONPROFESSIONALScott Gurney#PV-011719-015866CONTRACTOR:BRS FIELD OPS385-498-6700SPEC SHEETSS 6+((71$0(3$*(180%(5 5(9,6,21&21),'(17,$/7+(,1)250$7,21+(5(,1&217$,1('6+$//127%(86(')257+(%(1(),72)$1<21((;&(37%/8(5$9(162/$51256+$//,7%(',6&/26(',1:+2/(25,13$577227+(562876,'(5(&,3,(17625*$1,=$7,21(;&(37,1&211(&7,21:,7+7+(6$/($1'86(2)7+(5(63(&7,9((48,30(17:,7+2877+(:5,77(13(50,66,212)%/8(5$9(162/$5//&6663(&6+((7&2175$&725%56),(/'23639,167$//$7,21352)(66,21$/6FRWW*XUQH\391$%&(3&(57,),('15(6($5&+:$<%8,/',1*-25(087:::%/8(5$9(162/$5&20SFM SUNFRAMEMICRORAIL™INSTALLATION GUIDEPAGESYSTEM COMPONENTS CTrimrailTM FlashkitSub-Components: /)RRW+H[EROW7ULGULYHQXW&KDQQHO1XW6FRFNHW+HDG&DS6FUHZ&KDQQHO6OLGHUZJURPPHW3" Wide Flashing6WUXFWXUDO6FUHZ 66(3'0:DVKHUFunctions:•$WWDFK7ULPUDLOTMWRURRIDWWDFKPHQWˊDVKLQJ•3DWHQWHGURRIVHDOLQJWHFKQRORJ\DWURRIDWWDFKPHQWSRLQWFeatures: •6ORWSURYLGHVYHUWLFDODGMXVWPHQWVWROHYHODUUD\•6OLGHUSURYLGHVQRUWKVRXWKDGMXVWPHQWDORQJWKHVORSHRIWKHURRI• Shed and Seal Technology TrimrailTM and Module ClipsSub-Components: Trim RailModule Clip 7%ROW 7UL'ULYH1XWTrimrailTMFunctions: •5HTXLUHGIURQWURZVWUXFWXUDOVXSSRUWZLWKPRGXOHFOLSV•0RGXOHPRXQWLQJ•,QVWDOODWLRQDLG•$HVWKHWLFWULPFeatures: •0RXQWVGLUHFWO\WR/IHHW•$OLJQVDQGFDSWXUHVPRGXOHOHDGLQJHGJH•6XSSRUWVGLVFUHWHPRGXOHWKLFNQHVVHVIURP38, and 40mmModule ClipsFunctions: •5HTXLUHGIURQWURZVWUXFWXUDOVXSSRUWZLWKWULPUDLO•0RGXOHPRXQWLQJFeatures: •0RXQWVWR7ULPUDLOTMZLWK7EROWDQGWULGULYHQXW•0DQXDOO\DGMXVWDEOHWRˉWPRGXOHWKLFNQHVVHVDQGPPTrimrailTM SpliceSub-Components: 6WUXFWXUDO6SOLFH([WUXVLRQ %RQGLQJ&OLSFunctions: •)URQWURZVWUXFWXUDOVXSSRUW•,QVWDOODWLRQDLG•6WUXFWXUDOO\FRQQHFWVSLHFHVRI7ULPUDLOTM•(OHFWULFDOO\ERQGVSLHFHVRI7ULPUDLOTMFeatures: •$OLJQVDQGFRQQHFWV7ULPUDLOTM pieces•7RROOHVVLQVWDOODWLRQnopqnopqrtnous 6+((71$0(3$*(180%(5 5(9,6,21&21),'(17,$/7+(,1)250$7,21+(5(,1&217$,1('6+$//127%(86(')257+(%(1(),72)$1<21((;&(37%/8(5$9(162/$51256+$//,7%(',6&/26(',1:+2/(25,13$577227+(562876,'(5(&,3,(17625*$1,=$7,21(;&(37,1&211(&7,21:,7+7+(6$/($1'86(2)7+(5(63(&7,9((48,30(17:,7+2877+(:5,77(13(50,66,212)%/8(5$9(162/$5//&6663(&6+((7&2175$&725%56),(/'23639,167$//$7,21352)(66,21$/6FRWW*XUQH\391$%&(3&(57,),('15(6($5&+:$<%8,/',1*-25(087:::%/8(5$9(162/$5&20SFMSUNFRAMEMICRORAIL™INSTALLATION GUIDEPAGESYSTEM COMPONENTSDSFM Slider FlashkitSub-Components: 6OLGHU ZJURPPHW 6WUXFWXUDO 6FUHZ 66 (3'0 ZDVKHU :LGH)ODVKLQJFunctions: •3DWHQWHG 6KHG 6HDO URRI VHDOLQJ WHFKQRORJ\ DW URRI DWWDFK-PHQW SRLQW•)RU XVH ZLWK FRPSDWLEOH 0LFURUDLO RU $WWDFKHG 6SOLFHVFeatures: •6OLGHU SURYLGHV QRUWKVRXWK DGMXVWPHQW DORQJ WKHVORSH RI WKH URRI• Shed and Seal TechnologyWire Bonding Clip w/ 8AWGFunctions: •5RZ WR URZ ERQGLQJ•0RGXOH WR 7ULPUDLOTMERQGLQJ• Single Use OnlyFeatures: 7RROOHVV LQVWDOODWLRQMLPE Mounting AssemblySub-Components: 0/3( 0RXQW %DVH 6RFNHW +HDG &DS 6FUHZ %RQGLQJ 3LQFunctions: •6HFXUHO\ PRXQWV 0/3( WR PRGXOH IUDPHV•0/3( WR PRGXOH ERQGLQJFeatures: •0RXQWV HDVLO\ WR W\SLFDO PRGXOH ˊDQJH• UL2703 Recognized0/3( 0RGXOH /HYHO 3RZHU (OHFWURQLFVHJPLFURLQYHUWHU RU SRZHU RSWLPL]HUModule-to-Module N-S BondingSub-Components: &ODPS %RQGLQJ 3LQV 6RFNHW +HDG &DS 6FUHZ &ODPS %DVHFunctions/ Features: •5RZ WR URZ ERQGLQJ• Single Use Only•)LWV PRGXOH VL]HV PPTrim -to- Module Bonding Clampand Floating Trim ClampSub-Components: :HGJH %RQGLQJ 3LQ 7%ROW 1XW &DVW %DVHFunctions/ Features: •0RGXOH WR 7ULPUDLOTMERQGLQJVLQJOH XVH RQO\•$WWDFKHV 7ULPUDLOTMWR PRGXOH ZKHQ IHZHU WKDQ UDIWHU DWWDFKPHQW SRLQWV DUH DYDLODEOH•)LWV PRGXOH VL]HV PP•)LWV PRGXOH VL]HV PPonpnqpnpoonrpoq 6+((71$0(3$*(180%(5 5(9,6,21&21),'(17,$/7+(,1)250$7,21+(5(,1&217$,1('6+$//127%(86(')257+(%(1(),72)$1<21((;&(37%/8(5$9(162/$51256+$//,7%(',6&/26(',1:+2/(25,13$577227+(562876,'(5(&,3,(17625*$1,=$7,21(;&(37,1&211(&7,21:,7+7+(6$/($1'86(2)7+(5(63(&7,9((48,30(17:,7+2877+(:5,77(13(50,66,212)%/8(5$9(162/$5//&6663(&6+((7&2175$&725%56),(/'23639,167$//$7,21352)(66,21$/6FRWW*XUQH\391$%&(3&(57,),('15(6($5&+:$<%8,/',1*-25(087:::%/8(5$9(162/$5&20SFMSUNFRAMEMICRORAIL™INSTALLATION GUIDEPAGEFLASHING & SLIDERSGPILOT HOLES: 'ULOOSLORWKROHVIRUODJVFUHZVRUVWUXFWXUDOVFUHZVDVQHFHVVDU\DWPDUNHGDWWDFKHPHQWSRLQWVFLASHINGS:3ODFHˊDVKLQJVÔINSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS:• ,QVHUWˊDVKLQJVSHUPDQXIDFWXUHULQVWUXFWLRQVNOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" •$WWDFKVOLGHUVWRUDIWHUV•9HULI\SURSHUURZWRURZVSDFLQJIRUPRGXOHVL]H0RG16•(QVXUHWKDW7ULPUDLO70URRIDWWDFKPHQWVLQHDFKURZKDYHVXIˉFLHQWHQJDJHPHQWZLWKVOLGHUGRYHWDLOVIRUSURSHUDWWDFKPHQWINSTALL SLIDERS AND ROOF ATTACHMENTS:)ROORZPDQXIDFWXUHULQVWUXFWLRQVIRUˊDVKLQJLQVWDOODWLRQSURFHGXUHVNOTE: If N-S module edge is within 1” of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required.×UP-SLOPEDOWN-SLOPE×Mod NS + 1"Mod NS + 1"N/S MODULE EDGERotate SliderCut Shingles as RequiredLess Than 1"