Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA207885 - APPROVED - Varun Jain - PERMIT-PE LETTER-PLANS
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov Bldg and Elect Total $242.00 LH - email 10.28.2022 $201.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: X X (solar) 200.00 1.00 201.00 V-B 2020 IRC-1 PUD Rooftop Solar (15 Panels) DP 10/28/22 :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW -DLQ5HVLGHQFH *OHDPLQJ&W /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH-DLQ5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUW DOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD 6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU '0DLQOLQH'U :HVWILHOG0$ 'DWH2FWREHU 5HI Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 10/28/2022dpfannenstein Provide copy of city approved plans on the job site for the inspector Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 10/28/2022dpfannenstein For each roof plane with a photo-voltaic array, a 36 inch wide pathway shall be provided from lowest roof edge to ridge on the same roof plane, on adjacent roof planes. One shall be on street/driveway side. No less than 18 inch clear setback is required on both sides of a horizontal ridge, valley, or hip rec Alphα® pure Black Series Product Specifications α experience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 385 390 395 400 405 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14 Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3 Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9 Power Output - PMAX (Wp)293 297 301 305 309 Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 132 half-cut REC heterojunction cells with lead-free, gapless technology 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm) Weight:45 lbs (20.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:-40 ... +185°F (-40 ... +85°C) Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq ft)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending) ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 The high-powered smart grid-ready Enphase IQ 7A Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7A Microinverter To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Efficient and Reliable • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility.2. CEC peak power tracking voltage range is 38 V to 43 V.3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility.5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2019-11-07 INPUT (DC)IQ7A-72-2-US Commonly used module pairings¹295 W–460 W + Module compatibility 60-cell, 66-cell, and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range²18 V–58 V Min/Max start voltage 30 V / 58 V Max DC short circuit current (module Isc)³15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT (AC)@ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211–264 V 208 V / 183–229 V Maximum continuous output current 1.45 A (240 VAC)1.39 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47–68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit5 11 (240 VAC)11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0 %96.5% MECHANICAL Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type: DC (IQ7A-72-2-US)MC4 Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection — No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring optionsCompatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7A Microinverter snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience SnapNrack Umbrella Sealing Technology • Innovative Flashing Elevates Protection. New fl ashing uses a fully formed raised cone to prevent any potential water from getting into penetration. Feel secure as the fl ashing is one piece and doesn’t rely on multiple parts sealing together. • Mechanical Design Creates a Lifelong Seal. Patented Umbrella technology utilizes unique Umbrella Washer to seal lag bolt, L Foot, and fl ashing and prevent any potential roof leaks. Technology passes UL 2582 Wind Driven Rain Test without a rubber seal, however rubber gasket is included for extra peace of mind. • Single Fastener Eliminates Extra Steps. Utilize one lag bolt with Umbrella Washer to secure the entire mount assembly and fl ashing. No longer necessary to attach a base, then a fl ashing, then a mount as all are secured in one step. • Single Tool Installation. SnapNrack was the fi rst in the industry to develop a complete system that only requires a single tool. That tradition is continued as a ½” socket is still the only tool necessary to secure the mount as well as all other parts of the system. snapnrack.com Featuring New Innovative Flashing Smaller 9”x12” size allows for easier insertion under shingles Alignment markers make it easy to locate pilot holes Rounded corners make for easier insertion & eliminate corner points from folding up Note: Flashing shown in yellow for illustration purposes only. © 2018 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com snapnrack.com Ultra Rail, UR-40 Rail System Spans Wind (mph) 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 Snow (psf)0 5 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 120 System Span Key 6 ft Spans 4 ft Spans 2 ft Spans This table was prepared in compliance with applicable engineering codes and standards. Values are based on the following: • ASCE 7-10 • Chapter 30 Wind Loads & Chapter 7 Snow Loads • Roof Slope: 7 - 27 deg • Roof Height: 0 - 30 ft • Exposure: B • Roof Zone: 1 • Module Orientation: Portrait • Module Type: 60 Cell Modules • Roof Type: Comp Industry Leading Spans for a Light Rail Solution Visit SnapNrack.com for detailed span tables and certifi cations. Certifi cations SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 for wind-driven rain. Raised Cone Flashing Single Lag Secures Mount to Roof Pre-assembled Ultra Rail L Foot & Clamp Pre-assembled Ultra Rail