Loading...
HomeMy WebLinkAboutLA208763THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION: Please complete a separate application form for each sign. Payment for amount of permit. For freestanding/monument/pylon sign - a site plan with setback from property line dimensions and art work with dimensions of sign, and engineered design for footings and foundation. For wall sign, art work with dimensions of sign and drawings of building façade showing location of sign. If illuminated or if electrical services are needed, a separate electrical permit is required. If leased space, need to include a letter of approval from the property owner. SIGN LOCATION Name__________________________________________________________________________________ Address___________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ PROPERTY OWNER Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN CONTRACTOR Company Name _________________________________________________________________________ Address________________________________________________________________________________ City ___________________________________ State___________________ Zip _____________________ Contact ________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN DESCRIPTION Electronic ($100 per sign plus completion of electronic sign license, see Page 2) (1000.4114) Permanent ($75 per sign) (1000.4114) Temporary ($50 per event, up to 60 days per year. Max of one temp sign displayed at a time.) (1000.4114) Temporary sign displayed dates: START DATE ________________________ END DATE ________________________ Sign Type and Dimensions Wall Sign: Width ____________ Height: _______________ Square feet _____________________________ Freestanding: Face Width_________ Height____________ Sq. ft__________ Overall Sign Height _________ Setbacks: Front _________ Side ____________ Temporary Width___________ Height ______________ Sign Square Feet______________________ Display location _______________________ Illuminated Sign: Internally illuminated Externally illuminated Not illuminated Type of Work: New Sign Replacement Sign Alter Existing Sign Changeable Copy: No Changeable Copy Manual Changeable Copy Electronic Changeable Copy (Electronic sign will require annual license review & renewal, see Page 2) Applicant Signature: ____________________________________________Date:_________________ Applicant Printed Name: _______________________________________________________________ SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION City of Lakeville – Planning Department 20195 Holyoke Avenue - Lakeville, MN 55044 952.985.4420 - www.lakevillemn.gov WaterWerks Car Wash _20275 Heritage Dr Lakeville MN 55423 Schad Tracy Signs mmarshall@schadtracy.com 952-855-8659 Schad Tracy Signs 1610 E Cliff Road Burnsville MN 55337 _____Rick Ballantyne ________ mmarshall@schadtracy.com 952-855-8659 25' 6"46"97.75 LA208763 Rick Ballantyne 11/15/22 Stak Properies, LLC 6901 Laurel Ave Golden Valley MN 55426 kalthoff@londoinc.com 763-591-7522Karla Althoff SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION Page 2 Electronic Display/Changeable Copy Sign License By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every seven (7) seconds. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9.The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED APRIL 2022) X X X PUD X $75.00 $75.00 1 December 2022 *Email kjenson@lakevillemn.gov after installation for final inspection. SCALE: N/A 325 MINNESOTA AVE. N. P.O. BOX 357 ORONOCO, MN 55960 PHONE / 507-367 -2631 FAX / 507-367-2633 1610 E. CLIFF RD. BURNSVILLE, MN 55337 PHONE / 952-894-2421 FAX / 952-894-2748 Client: 00-00 NA NA NA NA NA NA 00-00 00-00 00-00 00-00 00-00 THIS IS AN ORIGINAL DRAWING PROVIDED AS PART OF A PLANNED PROJECT AND IS NOT TO BE EXHIBITED COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF SCHAD TRACY SIGNS OR IT’S AUTHORIZED AGENTS. ALL RIGHTS RESERVED. Date: Drawing Number: Sales Person: Scale: S U M M A R Y: CHANNEL LETTERS SPECIFICATIONS: FONT USED: LOGO D E A C B TRIM CAP L.E.D. UNITS WIRE CONNECTOR PENETRATIONS SEALED WITH SILICONE ACRYLIC FACE .040 ALUMINUM RETURN .050 ALUMINUM BACK 7.5”X3”RACEWAY PAINTED TO MATCH MOUNTING SURFACE POWER SUPPLY 120 VOLT SERVICE MOUNTING HARDWARE CONNECTOR LOW VOLTAGE WIRE GROMMET CHANNEL LETTER TYPICAL L.E.D. RACEWAY MOUNT CHANNEL LETTER SECTION DETAIL TRANS. VINYL COLORS WATERWERKS LOGO AND CAR WASH WATERWERKS LOGO AND CAR WASH 325 MINNESOTA AVE. N. P.O. BOX 357 ORONOCO, MN 55960 PHONE / 507-367 -2631 FAX / 507-367-2633 1610 E. CLIFF RD. BURNSVILLE, MN 55337 PHONE / 952-894-2421 FAX / 952-894-2748 Client: 00-00 NA NA NA NA NA NA 00-00 00-00 00-00 00-00 00-00 THIS IS AN ORIGINAL DRAWING PROVIDED AS PART OF A PLANNED PROJECT AND IS NOT TO BE EXHIBITED COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF SCHAD TRACY SIGNS OR IT’S AUTHORIZED AGENTS. ALL RIGHTS RESERVED. Date: Drawing Number: Sales Person: Scale: PROPOSED SIGNAGE PROPOSED EXISTING 13'-9 1/2" 24" 31"8" CHANNEL LETTERS SPECIFICATIONS: FONT USED: LOGO D E A C B TRIM CAP L.E.D. UNITS WIRE CONNECTOR PENETRATIONS SEALED WITH SILICONE ACRYLIC FACE .040 ALUMINUM RETURN .050 ALUMINUM BACK 7.5”X3”RACEWAY PAINTED TO MATCH MOUNTING SURFACE POWER SUPPLY 120 VOLT SERVICE MOUNTING HARDWARE CONNECTOR LOW VOLTAGE WIRE GROMMET CHANNEL LETTER TYPICAL L.E.D. RACEWAY MOUNT CHANNEL LETTER SECTION DETAIL REMOVE 42” 32” 17'-7"7'-0"24'-0 3/4" 3/16” PROPOSED EXISTING 34”46” 60” 11 5/8”45 1/4” 20'-0” 25'-6” SIGN A 11.14.2022 Marketing Manager LA208763