Loading...
HomeMy WebLinkAboutLA208867- 20467 Gargoyle Ln Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov CANNOT HOOK TO CITY SEWER/WATER RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 10'-0 1/4" 9'-1 1/8"T.O. FTN1st FLR.T.O. FTN1st FLR.2'-4"8'-1 1/8"2nd FLR.T.O. PLATET.O. PLATE1288122T/GAR. PL.8121288121283RIPPEDSTONE VENEERFACE APPLIEDSTONE WATERTABLEFACE APPLIED2JAMBINNER6'-0"DETAILSEE COLUMNCOMPOSITIONSHINGLES6:12 PITCH8:12 PITCH8:12 PITCHFLASHING4:12 PITCHFLASHING2HORIZONTALSIDING, TYP.6:12 PITCH128ADDRESSLOCATION1'-2 1/8"8" TRIM10" TRIM8" TRIM6" TRIM4" TRIM 4" TRIM4" TRIM4" TRIM 4" TRIM 4" TRIM 4" TRIM 4" TRIM, TYP.4" TRIM 4" TRIM4" TRIM8" TRIMSHAKE SIDING10" TRIM181261212312126812HORIZONTAL SIDING8:12 PITCH8:12 PITCH6:12 PITCH6128" TRIM9'-1 1/8"8'-1 1/8"T/FNDTN1st FLR.T/PL.T/PLATE2nd FLR.ROOF VENTS6:12 6:128:128:128:128:124:12 8:128:128:12 8:126:12 6:12 2'-0" 1'-11 1/4"EXTEND CRICKET18" PAST HOUSEROOF VENTS BY ROOFINGCONTRACTOR6' TYPICAL ICE & WATERSHIELD FOR EXTERIOR WALLS& 3' AT ROOF VALLEYS12" RAKE O.H. AT SIDE ELEV'S12" AT FRONT & REAR - TYP.SLOPE T.B.D.IN FIELDSTONE CAPFACE APPLIEDSTONE VENEERPIER24" x 16"5'-6 3/8"(FIELD VERIFY HEIGHT)8'-8 3/8"T/PORCH SLAB2'-0"2'-4"(+/-)3'-0"(+/-)(4-1/2 BLK CRS'S)8"4"8"8" SQUARECOLUMN, PVC OREQ. WRAP1x4 CAP TRIM, PVCOR EQ.1x6 BASE TRIM, PVCOR EQ.1 x 61 x 41 x 81 x 10CORNERS, GABLE RAKE, WINDOW APPLICATIONSGARAGE INNER JAMBS, WINDOW SILLS, GABLE RAKE, FASCIADOOR KICK PLATEKEYNOTE SYMBOLMATERIAL ON TRIM KEY1LOCATION OF MATERIAL1234EXTERIOR TRIM KEYFRIEZE, RETURNSSIDING MATERIALS PER COMMUNITY SPECIFICATIONS. STYLE PERPLAN.REPLACE 1/2" BUILT-RITE SHEATHING WITH 1/2" O.S.B. SHEATHINGBEHIND ALL VINYL AND LP BOARD & BATTEN AND / OR SHAKE SIDING.ALUMINUM FASCIA & SOFFIT ON ALL SIDES OF HOME, INCLUDES PORCHCEILINGALL TRIM MATERIALS SHOWN TO BE PER COMMUNITY SPECIFICATIONS.TRIM SIZED PER PLAN.PER PLAN AND COMMUNITY SPECIFICATIONS ONLY:WRAP ALL WINDOWS AT SIDES & REAR OF HOME W/ TRIMINSTALL HOUSE WRAP AROUND ENTIRE HOME, SEE DETAIL ON A4 FORINSTRUCTIONS ON WRAPPING THE WINDOWS11312661212881234126'-0"STOOPHORIZONTAL SIDING8:12 PITCH8:12 PITCHSTONE RETURNS 2' 28121282128COMPOSITIONSHINGLES6:12 PITCH6:12HORIZONTAL SIDING28121282128COMPOSITIONSHINGLES6:12 PITCH6:12T/BASEMENT SLABHORIZONTAL SIDING28121282128COMPOSITIONSHINGLES6:12 PITCH6:12HORIZONTAL SIDINGT/SLAB AND REAR FOUNDATION WALLSEE 10/A27'-7 1/4"28121282128COMPOSITIONSHINGLES6:12 PITCH6:12T/BASEMENT SLABHORIZONTAL SIDINGTRADITIONS SERIESEN06 E3 - SPRINGFIELDFOUNDATION PLAN & DETAILS ELEVATIONS, ROOF PLAN, NOTESSECTIONS ELECTRICAL PLANSA6MAIN AND SECOND FLOOR PLANS A2A3A5A1DETAILSA4F1FIREPLACE DETAILSL1LOWER LEVEL FINISH PLANSA7MORNING ROOM OPTIONGENERAL NOTES AND DETAILSS-0BASEMENT FOUNDATION PLANS-32ND FLOOR FRAMING PLANSS-4BRACED WALL & MISC. DETAILSSD-1BRACED WALL DETAILSSD-2FOUNDATION GUIDES1-S2ROOF FRAMING PLANS-5SCALE:A11FRONT ELEVATION1/4" = 1'- 0"SCALE:A12ROOF PLAN1/8" = 1'- 0"SCALE:A13SIDE ELEVATION1/8" = 1'- 0"SCALE:A14SIDE ELEVATION1/8" = 1'- 0"SCALE:A16COLUMN DETAIL1/2" = 1'- 0"SCALE:A15REAR ELEVATION-FULL FOUND.1/8" = 1'- 0"SCALE:A15BREAR ELEVATION-GARDEN FOUND.1/8" = 1'- 0"SCALE:A15CREAR ELEVATION-LOOKOUT 1/8" = 1'- 0"SCALE:A15DREAR ELEVATION-WALKOUT1/8" = 1'- 0"GARAGEMAIN FLOOR 636 SF1,214 SFSECOND FLOOR 1,225 SFTOTAL2,439 SFMORNING ROOM OPTION170 SFFIN. LOWER LEVEL OPTION1,033 SFBASEMENT UNFINISHED1,214 SFFIN. LL RECREATION RM. OPTION711 SFFACE APPLIED STONE VENEERVINYL SIDING ON FRONT ELEVATION.FACE APPLIED STONE VENEERSHAKE SIDINGHORIZONTAL LAP SIDINGVINYL SIDING ON SIDE AND REAR ELEVATIONS. 20467 Gargoyle Lane Cedar Hills-3rd AdditionSHAKE SIDINGHORIZONTAL LAP SIDINGMORNING ROOM SEE PAGE A7Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode10/27/2022dmathews W 8 x 13 x 19'-2" LSTL. BM. ABV.4" DIA. AFCO '4X' ADJ.STL. COLUMN ON36"x36"x16" DP. CONC.FOOTING. ADJUSTABLEPORTIONS OF COLUMNTO BE ENCASED INCONCRETE.4" DIA. AFCO '4X' ADJ. STL.COLUMN ON 30"x30"x12" D.CONC. FOOTING.ADJUSTABLE PORTIONS OFCOLUMN TO BE ENCASED INCONCRETE.10'-9"10'-0 1/2"HOLD T/WALLDN 12" TYP.SLAB ABOVE4" CONC. PORCH10'-6"17'-9"4'-4 1/2" 51'-10 1/2" 16'-0"15'-0"14'-6"45'-0"8"6"6'-1 1/2" 28'-7" 29'-9" SYSTEM ABOVE PRE-ENG FLOOR 6"8"SYSTEM ABV. PRE-ENG. FLRSUMP 8"15'-11"21'-0 3/4"6"18'-7"1'-11 1/4"1'-11 1/4"16'-1 1/2"20'-0"6" 2'-11"3'-7 1/8"3'-8 5/8"4'-4 1/2"SLOPE SLAB 4" TO DOOR CJCJ 17'-5 1/2"5'-10"3'-3"CJ SYSTEM ABV PRE-ENG FLR.3'-1"3'-1"5'-7"3'-1" CJ 20" WIDE X 8" DEEP(5,000 P.S.I.) TYP.CONT. CONC. FOOTING8"5'-3 1/2"6" ELEC. SLEEVE WATER SLEEVE 4" CONC. SLAB OVER6 MIL. VAPOR BARRIEROVER DEPTH OF FOOTING GRAVEL BASE (2500 P.S.I.)BASEMENT SLAB(3500 P.S.I.)GARAGE SLAB4" CONC. SLABFPHBSUB-SLABVENTSUMP PIT DISCHARGEFPHBTHICKNESS ANDNOTE:BASEMENT WALLREINFORCING PERIRC SEC. R404BATHROUGH-INPRE-ENG FLOOR SYSTEM ABOVE PRE-ENG FLOOR SYSTEM ABOVE 39'-9"33'-3"8"8"4'-6"8"5'-10"2'-11"DROP PIT 8"PIT DRAIN18'-4 1/2"PLACE WEEP TUBESEVERY 6' IN FOOTINGF.D.WHFURNAIR EXCHANGER5'-4"5'-11"12'-8 1/2"16'-7"8"x4"x8 1/4" D.BM. POCKET(TYPICAL)EGRESS PITLADDERINTERIOR STUD BEARING WALLW/ 2x6 STUDS AT 16" O.C., DBLTOP PLATE AND P.T. SILL PLATEON 17" W x 8" DP. CONC. FOOTING5 1/2"ADD R-10 RIGID INSULATION7'-1 1/4"1'-4"4" 28'-8 1/2"6" 49'-10 1/2" 20'-1"9'-9 1/2" 4'-4"8" 3'-8"8"10'-0"11 1/4"8'-1 1/2"11 1/4"19'-6"6"1'-6"6" 2'-0"5'-1 1/2"OPTIONAL WET BAR ROUGH-IN 4'-10 1/2"6'-8"UP (15) EQ. RISERS (16 R. W/ AT 9' FOUND.)W/ 10" TREADS1 1/2" OVERHANG OF FLOOR ABOVEINSTALL 2" R-10 RIGID INSULATIONAROUND PERIMETER OF HOUSEFOUNDATION, TYP.POUR GARAGE SLAB FLUSH45°6"2"4" LEDGE AT GARAGE COMMON WALL2" LEDGE AT GARAGE WALL-TYPICAL1 1/2"4"6"2"6"10"2'-11"6'-2 1/4"1 1/2"21'-5 1/2"3'-5"4'-1 1/2"GARAGE DOORDROP FDTN 8" AT22'-0"1 1/2"GARAGE DOORDROP FDTN 8" ATSTUD BEARING WALL W/ 2x4STUDS AT 16" O.C., DBL TOPPLATE AND P.T. SILL PLATE ON17" W x 8" DP. CONC. FOOTING℄(2) 1 3/4"x11 7/8" LSLW/ (1) JACK EA. ENDSYSTEM ABOVE PRE-ENG FLR.2838CSMT. WDW.WD. FRAMINGAT HATCHED AREAHATCHED AREADEFINES 80 S.F.UNPROTECTEDFLOOR AREA5'-8"EL.= 0'-0"(FULL HEIGHT)T/ FDN.EL.= MINUS 3'-10"T/ FDN.(1) JACK EA END(3) 2x10 HDR W/4636 SLIDER8'-5"T/ FDN.EL.= 0'-0"EL.= MINUS 3'-10"T/ FDN.2x8 STUD KNEE WALL W/ STEM FNDTN WALLSTUDS AT 16" O.C. ON 3'-6" HIGH(3) 2x10 HDR. W/4636 SLIDER25'-8"(1) JACK EA ENDEXTEND FULL HT.CONC. WALL TO REARCORNEREXTEND FULL HT.CONC. WALL TOREAR CORNER39'-9"SUMP PIT DISCHARGEPT. LOAD AT ELEV. E8" 7 1/4"1 1/2"8"1 1/2"INSIDE FACE OF FOUNDATIONWALL BELOW(MINUS 4'-6" AT9' BSMT. OPT.)(MINUS 4'-6" AT9' BSMT. OPT.)CORRUGATED STEEL EGRESS WELL75"W. x12"H. x 36"5'-6"MINUS 5'-6" @ 9' FND.MINUS 4'-10 @ 8'-4" FND.2'-3"MINUS 4'-6" @ 9' FND.MINUS 3'-10" @ 8'-4" FND.20'-2"MINUS 4'-6" @ 9' FND.MINUS 3'-10" @ 8'-4" FND.5'-6"MINUS 5'-6" @ 9' FND.MINUS 4'-10 @ 8'-4" FND.5'-0"MINUS 4'-6" @ 9' FND.MINUS 3'-10" @ 8'-4" FND.FPHBADD R-5 "THERMAX"INSUL. TO SIDEWALLS4" GRANULAR FILL20" x 8" CONC. FTG.W/ SILL SEALER(TR) 2x6 SILL PLATEGRADER-20 BATT INSUL.BOLT AT 72" O.C.1/2" DIA. x 10" ANCHOR8" T. POURED CONC.FOUNDATION WALL CONC. SLABPER PLANEXT. FIN. PER PLANDOUBLE TOP PLATEHEADER AT WIN.4 MIL POLY8"2"TYVEK WITH SIDINGPER PLAN FL. SYSTEM(EXT. PER PLAN)VAPOR BARRIERR-10 RIGID INSUL.OR APPROV. STRAPMIN. 42"WATERPROOFINGREQ'D. @ TOP OFFDN. WALLR-20 INSUL. @ RIMRIM BOARDCONC. SLAB20" x 8" CONC. FOOTINGFOUNDATION WALLDOUBLE TOP PLATEPER PLANFL. SYSTEM8" T. POURED CONC.1/2" DIA. x 10" ANCHORBOLT AT 72" O.C.R-20 BATT INSUL.2x8 (TR.) SILL PLATEW/ SILL SEALERGRADEEXT. FIN. PER PLANOR APPROV. STRAP3'-6"R-20 SPRAY FOAM INSUL.RIM BOARDR-10 EXT. FDN. INSUL.1/2" SHEATHINGR-5 RIGIDINSULATIONWATERPROOFINGTOP OF FDN. WALLCANT PLATE 1 1/2"SQUASH BLOCKS@ ALL POINT LOADS2x8 STUDS @ 16" O.C.SIDE WALLWALKOUTFDN. ONLY4" WEEPS EVERY 6'WATERPROOFINGAT FOUNDATION4" D. x 8" H. LEDGEPER PLANSUBFLOORFLOOR SYSTEMRIM BOARDCONC. STOOP8" FIN. FLR. MAX. TO10"30 MIL PVC MEMBRANESEAL ALL SEAMS,CORNERS & EDGES W/35 MIL POLYETHYLENEBACKED SYNTHETICBUTYL RUBBERADHESIVE MEMBRANE1/2" SHEATHING(2") R-10 EXTERIORR-20 SPRAY FOAM INSUL.WATERPROOFINGREQ'D.@ TOP FDN.FOUNDATION INSULATION2x8 SILL PLATEW/ ANCHOR BOLTS1 1/2" CANT'D. ALIGN W/ FDN. WALLSUBFLOORFLOOR JSTS/TRUSSES20"x8" CONC. FOOTING2x6 TOP PLATECONC. SLABPER PLANPER PLAN16" O.C. (TYP)2x6 STUDS @2x6 TREATEDPLATESECURED W/POWDEREDACTUATEDFASTENERS@ 24" O.C.1"4"x1/2" TRT'D.PLYWOOD,HOLD UP 1"FROM FTG.EACH SIDEU.N.O. BY ENGINEERGRADEWINDOW WELL WITH8" POURED CONCRETEPER PLANEGRESS WELLDRAIN FIELDBATT INS.(TR) 2x8" SUBFRAMESOCKED DRAINTILE CONNECTSTO INTERIORN.T.S.MIN. PER EGRESSNOTE:44" MAX. FROMT.O. SLAB TOWIN. EGRESSLADDERPER PLAN HEADER PER PLAN42"4'-4"WATERPROOFINGPER PLANFL. SYSTEMRIM BOARD (BY MFG.)EXT. FIN. PER PLANRIGID INSUL.R-10 EXT. FDN.1/2" EXT. SHEATHINGWATERPROOFING2X8 SILL PLATECANT. 1 1/2"2X8 STUDSPERIMETER OUTSIDE WALLSWATERPROOFING ALLWALLS BELOW GRADE4" WEEPSEVERY 6'FLR. TRUSS 20" x 8" CONC. FOOTINGPER PLANPER PLANWATERPROOFINGVAPOR BARRIER4" GRANULAR FILL4" CONC. SLAB2X4 RIBBON ATTACH TOP/BTM.1/2" EXT. SHEATHINGR-10 EXT. FDN.INSUL. ABOVE GRADE8"2" CERTI STUDR-20 SPRAY FOAMINSULATIONWATERPROOFINGREQ'D. AT TOPFDN. WALL2X8 SILL PLATEW/ ANCH. BOLT1 1/2" CANT.WITH .135"X3.5" BOX NAILSHOUSE BASELINE DIM.NOTE: NO R-5 INSUL.REQ'D. AT FULL BSMT.2X6 STUDS @ 16" O.C.R-10 EXT. FDN.INSULATION / DRAIN BOARDBELOW GRADEXP BOARD@ 6" O.C. THROUGHOUT4X2 GABLE FLOOR TRUSSSET IN 1 1/2", ALIGN W/ FDN. WALL(1) NAIL INTO EA. WEB4" WEEPS EVERY 6'SYSTEMFLR. TRUSS 20" x 8" CONC. FOOTINGPER PLANPER PLANWATERPROOFINGVAPOR BARRIER4" GRANULAR FILL4" CONC. SLAB2X4 RIBBON ATTACH TOP/BTM.1/2" EXT. SHEATHINGR-10 EXT. FDN.INSUL. ABOVE GRADE8"2" CERTI STUDR-20 SPRAY FOAMINSULATIONWATERPROOFINGREQ'D. AT TOPFDN. WALL2X8 SILL PLATEW/ ANCH. BOLT1 1/2" CANT.WITH .135"X3.5" BOX NAILSHOUSE BASELINE DIM.NOTE: NO R-5 INSUL.REQ'D. AT FULL BSMT.2X6 STUDS @ 16" O.C.R-10 EXT. FDN.INSULATION / DRAIN BOARDBELOW GRADEXP BOARD@ 6" O.C. THROUGHOUT4X2 GABLE FLOOR TRUSSSET IN 1 1/2", ALIGN W/ FDN. WALL(1) NAIL INTO EA. WEB4" WEEPS EVERY 6'SYSTEM5'-8"EL.= 0'-0"(FULL HEIGHT)T/ FDN.EL.= MINUS 4'-10"T/ FDN.(1) JACK EA END(3) 2x10 HDR W/4636 SLIDER8'-5"T/ FDN.EL.= 0'-0"EL.= MINUS 4'-10"T/ FDN.2x8 STUD KNEE WALL W/ STUDSSTEM FNDTN WALLAT 16" O.C. ON 3'-6" HIGH(1) JACKS EA END(3) 2x10 HDR. W/4636 SLIDER(3) 2x10 HDR. W/4636 SLIDER9'-9"(1) JACK EA ENDADD R-5 "THERMAX"INSUL. TO SIDEWALLSEXTEND FULL HT.CONC. WALL TO REARCORNEREXTEND FULL HT.CONC. WALL TOREAR CORNER15'-11"39'-9"SUMP PIT DISCHARGEPT. LOAD AT ELEV. E8" 7 1/4"1 1/2"8"1 1/2"INSIDE FACE OF FOUNDATIONWALL BELOW(MINUS 5'-6" AT9' BSMT. OPT.)(MINUS 5'-6" AT9' BSMT. OPT.)FPHB4" CONC. SLABFLOOR SYSTEMGARAGE SLAB SLOPE: 4"20" x 8" CONC. FOOTINGPER PLAN20" x 8" CONC. FOOTING8"PER PLANWATERPROOFINGB.O. FTG.GRADE3'-6" MIN.VAPOR BARRIER4" GRANULAR FILL4" CONC. SLABTOP OF CURBTOP OF FDN.TREATED 2x SILLPLATE W/ SILL SEALERSHEATHINGEXT. MTR'L. PER PLANRIM BOARD (BY MFG.)5/8" GYP. SHEATHINGR-10 EXTERIOR FDN.INSULATION10"6"4"2" CERTI-STUD ATFOUNDATION LEDGER-20 SPRAY FOAMINSULATIONWATERPROOFINGREQ'D. AT TOP OFFOUNDATION WALL2x6 SILL PLATEW/ ANCHOR BOLT / STRAPNO CANT. AT GARAGESTD. RIM DETAILHOUSE BASELINE DIM.GAR. OUT TO OUT DIM.NOTE: NO R-5 INSUL.REQ'D. AT GAR./HOUSEINT. COMMON WALLS4" WEEPS EVERY 6'4"(PLATE SIZE PER PLAN)(2) 2x10 HDR. W/(1) JACK EA END30 50(1) JACK EA END(2) 2x10 HDR. W/6068 SGD(2) 2x10 HEADERW/ (1) JACK EA END6'-11"W/ STUDS AT 16"O.C.2x6 BEARING WALL T/ FDN.EL.= MINUS 8'-0"EL.= 0'-0"(FULL HEIGHT)T/ FDN.EL.= MINUS 4'-6"T/ FDN.W/ STUDS AT 16" O.C.STEP FNDTN WALL2x8 STUD KNEE WALL 15'-0"18'-0" TO FOOTING STEP 18'-0" 15'-0"3'-8" FOOTING STEPT/ FDN.EL.= 0'-0"T/ FDN.EL.= MINUS 4'-6"T/ FDN.EL.= MINUS 8'-0"SEE 10/A2ON 4'-0" HIGHSTEM FNDTN WALLSUMP PIT DISCHARGE5'-8"16'-11 1/2"8"30 5010'-2 1/2"PT. LOAD AT ELEV. ELINE OF FOUNDATIONWALL BELOW39'-9"8"5 1/2"1 1/2"8"7 1/4"7 1/4"ADD R-5 "THERMAX"INSUL. TO SIDEWALLS(MINUS 8'-8" AT9' BSMT. OPT.)(MINUS 8'-8" AT9' BSMT. OPT.)(MINUS 5'-6" AT9' BSMT. OPT.)(MINUS 5'-6" AT9' BSMT. OPT.)GFIP (WP)FPHB3'-8" FOOTING STEPTO FOOTING STEP FOUNDATION NOTES:1. MAXIMUM WALL LENGTH WITHOUT A CONTROL JOINT TO BE 50'-0".2. PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOORCONSTRUCTION AT BOTH TOP AND BOTTOM OR BY ADEQUATE TEMPORARY BRACING.3. EXTERIOR WATERPROOFING SHALL COMPLY W/ R 406.2, PER 2020 MN RESIDENTIAL CODE.WATERPROOFING SHALL EXTEND FROM TOP OF INTERIOR FOUNDATION WALL, ACROSS TOP OF WALLAND DOWN THE FACE OF EXTERIOR FOUNDATION WALL TO FOOTING.4. EXTERIOR FIBER BOARD INSULATION TO BE APPLIED OVER WATERPROOFING.ABOVE GRADE TO BE 2" THICK, R-10 CERTISTUD (OR EQUAL) TO ALLOW FOR SIDING INSTALLATION.BELOW GRADE TO BE R-10 FIBERBOARD (WATCHDOG OR EQUAL), IN 2 3/8" THICKNESS. SILL PLATE TOOVERHANG FOUNDATION BY APPROX. 1 1/2" TO ALLOW FOR EXTERIOR 1/2" SHEATHING TO ALIGN WITHFOUNDATION INSULATION. A GROUND BREAKER MATERIAL TO BE USED TO TRANSITION BETWEEN 2"CERTISTUD INSULATION / 2 3/8" INSULATION BELOW AND GRADE.5. WALLS WITH EQUAL BACKFILL ON BOTH SIDES REQUIRE NO REINFORCING FOR WALL LENGTHS LESSTHAN 25'-0" LONG AND HORIZONTAL REINFORCING ONLY FOR WALLS LONGER THAN 25'-0".6.INDICATES NUMBER OF TRIM JACKS AND KING STUDS AT WINDOW OR DOOR OPENINGS.7. 2x8 FRAMED WALLS AT LOOKOUT AND WALKOUT RETURNS.2x10TREATEDBACK TO ALLOW HOLD FNDTN. WALLFOR 2x BLOCKING8"8"SCALE:A21FOUNDATION PLAN1/4" = 1'- 0"SCALE:A21AGARDEN FOUNDATION1/4" = 1'- 0"SCALE:A21BLOOKOUT FOUNDATION1/4" = 1'- 0"SCALE:A27BEARING WALL3/4" = 1'- 0"SCALE:A28DETAIL AT STOOP3/4" = 1'- 0"SCALE:A24EGRESS WELL DETAIL3/4" = 1'- 0"SCALE:A23FULL FOUND. / SIDE WALL DETAIL3/4" = 1'- 0"SCALE:A22FULL FOUND. / REAR WALL DETAIL3/4" = 1'- 0"SCALE:A25LOOKOUT DETAIL3/4" = 1'- 0"SCALE:A26WALKOUT DETAIL3/4" = 1'- 0"SCALE:A21CWALKOUT FOUNDATION1/4" = 1'- 0"SCALE:A29NON-DROPPED GARAGE / COMMON WALL3/4" = 1'- 0"SCALE:A210CORNER DETAIL @ FOUNDATION WALL3/8" = 1'- 0"8'-6"8'-6"10'-0"3'-9"5'-3"4'-9"(3) 3050 MULLED(2) 2x10 HDR6068 S.G.D. (2) 2x12 CONT. (1) JACK EA. END (1) JACK EA. ENDSYSTEM ABOVE PRE-ENGINEERED FLOOR SUMP PIT DISCHARGEW8 x 18 x 16'-8" STEEL BEAMW/ (6) JACKS EA. END42"x42"x18"D. CONC. FOOTINGW/ (5) #4 BOTT. EA. WAYPROVIDE SQUASH BLKNG@ WEB OF STL BM @BEARING LOCATIONS (TYP.)17'-0"INSIDE FACE OF FNDTN.WALL BELOWW/ STUDS AT 16"O.C.2x6 BEARING WALL 5 1/2"5 1/2"1 1/2"T/ FDN.EL.= MINUS 8'-0"EL.= MINUS 8'-0"T/ FDN.(MINUS 8'-8" AT9' BSMT. OPT.)(MINUS 8'-8" AT9' BSMT. OPT.)SCALE:A73WALKOUT FOUNDATION PLAN1/4" = 1'- 0" 16'-1 1/2"15'-5 1/2"16'x8' OVERHEAD DOOR16'-1 1/2"45'-0"20'-0"40'-0"52'-0"30'-0"12'-4 1/2"(2) 3060 MULLED(1) 2x6 JACK EA. END(2) 2x10 HDR. W/15'-0"3'-1 1/2"1'-11 1/4"3 1/2"5'-9 1/2"10'-2 1/2"22'-11 1/2"16'-1 1/2"7"13'-11"(2) JACK EA END(3) 2x10 HDR. W/1'-11 1/4"8'-6 1/2"LINE OF 2ndFLOOR ABV.(TO STOOP)6'-0"16'-0"(4) 2x6JACKSAT WALLS & CLG.ADJ. TO HOUSE1/2" GYP. BD.KITCHENBREAKFAST4'-6"1'-11"11"WALL BELOW, TYPICAL.NOTE: GARAGE DOORBEAR ON RAISED FNDTN.HEADER JACK STUDS TO6'-7 1/2"2'-2 1/2"4'-2"(2) 2x10 HDR(1)JACK EA ENDREFRSTEP DN (3) R 02A421'-8 1/2"6'-4 1/2"5'-1"3'-8 1/2"5'-3 1/2"2'-1"4'-1 1/2"3'-2"2'-1"3'-4"2'-3"2'-3"3'-8"1'-10"DW02A4(2) 1 3/4" x 11 7/8" LSLFLUSH7" 3" RANGE 3'-7"19'-9 1/2"5'-1 1/2" 19'-8 1/2" 3 1/2"3 1/2"2'-0"5'-0"10'-0"5 1/2" 52'-0"(2) 2x6 JACKS EA END(3) 1 3/4" x 11 7/8" LSLW/ (2) JACKS EA. END5 1/2"5 1/2"5 1/2"5 1/2" 5 1/2"5 1/2"29'-10" 5 1/2" EQUALEQUAL 3 1/2"21'-7"STONE VENEER17'-4"COL. BASE)(TO C.M.U.4'-6"4'-4 1/2"1'-4"4'-4 1/2"4'-10"10'-7 1/2"5'-9 1/2"5'-6"TO WALL)(C.M.U. COL. BASE14'-10"8"4"8"7'-4"6'-6"2'-0"5'-4"2'-0"TO C.M.U. COL. BASE)(C.M.U. COL. BASE4x4 P.T. POST W/ 'SIMPSON' ABA442 BASE AND BCS2-2/4 CAP (TYP.)3'-6"1'-3"(2) 2x8 HDR2"ROOF TRUSSES ABV@ 24" O.C. - TYP8'-0"JACKS(3) ROOF GIRDER TRUSS ABV 8'x8' OVHD DR(4)JACKS EA END HIP GIRDER TRUSS ABV (2) 2x6CRIPPLESROOF TRUSSES ABOVE @ 24" O.C. - TYPICAL (2) 2x4 JACKS(3) 2x12 HEADER W/W/ (2) 2x4 JACKS EA. END(2) 1-3/4"x 11-7/8" LSL3 1/2"VENEERSTONE2'-0" STONERETURN1/2" TYP. "X" GYP. BD.A.C. AREAS ONLYCONCRETE SLAB W/GARAGE@ WALLS AND CEILING @ HIP GIRDER TRUSS ABV8'-1 1/2"11 1/4"11 1/4"PORCHCONC.TRUSSES ABVMONO ROOF PRE-ENG. FLR. SYSTEMABOVE, SEE LAYOUTPRE-ENG. FLR. SYSTEMABOVE, SEE LAYOUTJOISTS ABOVECANTILEVERED FLR.FOYER2-STORY2nd FLR. LINEABOVESIDELIGHTW/ 12"3068& TRANSOM 6068 SGD30 40(3) 3050 MULLEDPOWDER2 4 6 8 24 6 82468PHPED. LAV. 1R/1S 1R/1S 2x6 WALL DROPCEILING2x6x12 DP.DROPPEDSOFFITTRFLR BRK12"OVERHANG10"SHADED WALLSINDICATE INTERIORBEARING WALLS W/STUDS AT 16" O.C.W/ DOUBLE TOPPLATEFAMILY ROOM2x STUDSTURNEDFLATWISEOPTIONAL DIRECT VENTFIREPLACE LOCATIONS (SEESHEET F1 FOR F.P. DETAILSAND STRUCTURALMODIFICATIONS)NOTE:HVAC CHASE, NOJOISTS BELOWFLOOR BREAK PER SPEC LEVEL PRE-ENG. FLR. SYSTEM ABOVE, SEE LAYOUT 1 3/4"x9 1/2" LSL 3'-1"5 1/2"11'-1"5'-10"4 SHELVES3'-1"PANTRY2668266826683'-6"3A3RAILING4'-6"9'-1"(2) 2x10 HDR/1JACK EA. END(2) 1 3/4" x 11 7/8" LSL (FL) ABV.(2) 2x6 JACKS(2) JACKS 6'-11"2'-5 3/4"3'-8 1/2"(3) 2x4 JACKS(2) JACKS 45°(4) JACKS5'-0"DN (15) R. W/ 10" T.16 R W/ 9' FND.28686'-6 1/2"MUDROOMW/ (2) 2x6 JACKS(3) 1 1/2" x 9 1/2" LSLAT EACH END3'-3"7'-0 1/2"W/ 10" TREADSUP (16) EQ. RISERS(2) 2x6 JACKS3"(3) JACKS2'-0"FLR BRK DINING ROOMOPTIONAL FLEX RM4'-2"FLR BRKHDR-DRP'D.W/ 2 JACKSEA. END(2) 2x10 CONT.ROOF GIRDER TRUSS ABOVEROOF GIRDER TRUSSROOF GIRDER TRUSS ABOVE (2) 2040 FIXEDBEDROOM #430 50BEDROOM #24068 BI-PASS(2) 3050 MULLED2668OPEN TOBELOW1R/1S@ 24" O.C. - TYPICAL ROOF TRUSSES ABOVE 5068 BI-PASS 26681R/1S BEDROOM #31R/1S 5068 BI-PASS 30 50(2) 3050 MULLED 13'-8 1/2"11'-2"40'-0"5'-9 1/2"12'-7 5/8"2'-1"10'-2 1/2"14'-9"5 1/2"5 1/2"5'-0" 32'-0" 5 1/2"9'-11"2'-1"10'-1 1/2"5 1/2"12'-0 1/2"6'-0 1/4"11'-1 1/2"6'-0 1/4"5 1/2"24'-9 1/4"5'-7"40'-0"5 1/2"3'-2 1/4"6'-7"5 1/2"2'-0"6'-9 1/2"3'-1"5'-7 1/2"3'-1"6'-3 1/2"6'-5 1/2" 3'-1" 13'-0 1/2"27'-11 1/2"(4) SH.16681'-9 1/2"WD7'-10 3/8"266813'-11"OWNER'S SUITE5'-1"9'-2 1/2"W.I.C.1R/1S 1R/1S2x6 WALL3'-4 1/2"28684036 FIXED (SAFETY)24" T.B.3'-7"24682068(4) SH.2'-0"2'-7"6'-1"PH3'-3"2x6 WALL 42" x 60"TUB6" TALL TILEBORDER(3 SIDES)4'-10"3'-10"5 1/2" 30'-0" 16'-9"5 1/2" 2'-6" 5'-0"5'-0" 1'-5 1/2"5'-1"2'-9 1/2"34"x60"SHOWER2'-10"24" T.B.HALL BATH2468266822"x30"ACCESSATTIC2'-9 1/2" 9'-0"32x60W/SH2'-6"FURR-OUTWALL 1/2"FLR BRK FLR BRKFLR BRK24682'-10"PH1'-5" ℄CASEMENTMULLED(2) 2x10 HDR (1) JACK EA END 2'-6"NOTE: ADD 3050 WDW TO ELEV. 'ET' ONLY (3) 2x10 HDR(2) JACKS EA END(1) JACK EA END(2) 2x10 HDR(2) JACKS EA END(2) 1 3/4" x 9 1/4" LSL8'-0"6'-0"(2) 2x6 JACKS(2) 2x10 HDR(1) JACK EA END(2) 2x10 HDR(1) JACK EA END(2) 2x10 HDR (1) JACK EA ENDWIRE SHELF @ 64" A.F.F.LAUNDRY2'-4"℄48" H. WALLW/ WOOD CAPRAILINGOWNER'SBATH42" H. HALFWALLW/ WOOD CAP5'-0"3'-3"4'-2 1/2"8'-5 1/2"3 1/2"60" VANITY OPT. FREESTANDING L.TUB1'-5"w/ 10" TREADSDN. (16) EQ. RISERSOPTOPTCASEMENT GENERAL NOTES:·MAIN FLOOR CEILINGS TO BE 9'-1 1/8" ROUGH CEILING HEIGHT (U.N.O.)·T.O. MAIN FLOOR WINDOWS TO BE FRAMED AT 8'-0" (U.N.O.)·UPPER FLOOR CEILINGS TO BE 8'-1 1/8" ROUGH CEILING HEIGHT (U.N.O.)·UPPER FLOOR WINDOWS TO BE FRAMED AT 6'-11 3/8" (U.N.O.)·SEE DETAILS SHEET, DETAIL #'s 11 & 12 FOR TYPICAL WINDOW FRAMING·ALL EXTERIOR HOUSE WALLS TO BE 2x6 @ 16" O.C. (U.N.O.)·GARAGE/HOUSE COMMON WALLS TO BE 2x6 @ 16" O.C. (U.N.O.)·INTERIOR WALLS TO BE 2x4, WITH EXCEPTION TO THE 2x6 PLUMBING AND BEARINGWALLS PER PLAN (U.N.O.) ALL INTERIOR WALLS TO BE FRAMED @ 16" O.C. MAINFLOOR BEARING WALLS SHALL BE FRAMED W/ STUDS ALIGNING WITH I-JOISTSABOVE. REFER TO I-JOIST LAYOUTS·WINDOW AND DOOR HEADERS TO BE (2) 2x10 (U.N.O.)·ALL DIMENSIONS ARE TO ROUGH FRAME (U.N.O.)·S.R.O. SIZES LISTED ARE THE FINISHED SHEETROCK OPENING WIDTH AND HEIGHTPER PLAN (EXAMPLE: 2680 OR 2/6x8/0 = 2'-6"x8'-0")· INDICATES A LOAD BEARING POINT, IF NOT SHOWN ON PLAN MINIMUM BEARINGOF (2) 2x4 IS REQUIRED AT END OF ALL HEADERS.· INDICATES NUMBER OF TRIM JACKS & KING STUDS AT WINDOW HEADERS,UNLESS A 2 STORY WALL SITUATION IS PRESENT·FLOOR BREAK INDICATES CHANGE IN FLOORING MATERIAL, REFER TO THESPECIFICATIONS FOR ACTUAL FLOORING MATERIALS SELECTED·REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCES & THE APPROPRIATEELECTRIC OR GAS HOOK-UP REQUIREMENTS FOR EACH·REFER TO SPECIFICATION INFORMATION FOR ALL TUB AND SHOWER SURROUNDMATERIALS·REFER TO SPECIFICATION INFORMATION FOR ALL KITCHEN & BATH CABINETFEATURES WHERE AVAILABLE PER CABINET SUPPLIER·ALL CLOSETS, PANTRYS, & LINENS TO RECEIVE WIRE SHELVING, (U.N.O.)·BLOCK SLIDING GLASS PATIO DR TO PREVENT OPENING PAST 4" MAX·ALL WASHERS ON LEFT SIDE & ALL DRYERS ON RIGHT SIDE·WINDOW FALL PROTECTION TO BE PROVIDED IN ACCORDANCE W/ R312.2(1) KING(2) TRIMBREAKFASTREFDW10" OVERHANG4'-6 1/2"OVEN 4'-6"PANTRY4 SHELVES4'-2"8'-10 1/2"2'-6"11"DISPOSAL SWITCHDISP.6'-0"CAPPEDFIXTURE R.I. HOODGFIP LLLLLLLKITCHENGOURMET4'-6"3'-6"GFIP CHFLR BRK3 266826682x STUDSTURNEDFLATWISE5 1/2"5 1/2"TILEDSHOWERBASESHOWERCONTROL2'-9 1/2"2x6 WALL 10'-5 1/2" 2020 (4) SH.5'-1"5'-5"3'-6"2'-0"2'-7"6'-1"2'-9 1/2"PH3'-3"11'-9"2x4 WALL1'-9"RAISED PLATFORM,SEE DETAILFRAMED GLASS SHOWERSURROUND FROM 42"A.F.F. TO 92" A.F.F. LEAVE4" AIR SPACE ABOVE42" H. 2x4 TILEDHALF-WALL, SLOPEDCAP FOR DRAINAGEBULLNOSE TILEAT WINDOW ANDFRAMED GLASSOPENINGSCORNER BENCHFRAMED @ 18"HIGH TILED TOPAND FACE W/SLOPED TOPSHELF LEDGE2X6 WALLFRAMED 18"HIGH. TILED W/SLOPED TOP3'-9"1'-0 1/2"1'-1"6'-2"24" T.B.1R/1S 1R/1S2'-4"4'-10"9"2'-7"5" 7"3'-10"SAFETY GLASS FLR BRK48"H HALFWALLW/ WOOD CAP24" T.B.2x6 WALL W.I.C.246820682468LL(2) 2x10 HDR(1) JACK EA END2068206826682-STORYFOYERFLEX ROOMKITCHENPANTRYSIDELIGHTW/ 12"3068JOISTS ABOVECANTILEVERED FLR.(2) 3060 MULLED(2) 2X10 HDR. W/(1) 2x6 JACK EA. ENDFLOOR ABV.LINE OF 2ndSHADED WALLS INDICATE INTERIORBEARING WALLS W/ STUDS AT16" O.C. W/ DOUBLE TOP PLATE7"12'-4 1/2"6'-11"2'-1"11'-1"5 1/2"FRENCHDOORS2'-1"2nd FLR. LINE ABOVE 7'-3 1/2" MM 3FLR BRKFLR BRK LLLL36'-0 1/2"9'-0 5/8"ALIGN W/BOTTOM OFCABINET3'-0 1/8"SCALE:A31FIRST FLOOR PLAN1/4" = 1'- 0"SCALE:A32SECOND FLOOR PLAN1/4" = 1'- 0"SCALE:A3OPT3FLEX ROOM OPTION1/4" = 1'- 0"SCALE:A3OPT2SERENITY SHOWER OPTION1/4" = 1'- 0"SCALE:A3OPT1GOURMET KITCHEN OPTION1/4" = 1'- 0"SCALE:A33KITCHEN DETAIL AT REFRIG.3/8" = 1'- 0"-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3'-9"17'-0"8'-0 1/2"5 1/2"4'-9 1/2" 10'-0" 4'-9"8'-0 1/2"5 1/2"5 1/2"6'-6"(3) 2x12 HDR (1) JACK EA. END 6068 S.G.D.TRUSSES ABOVE AT 24" O.C.PRE-ENGINEERED ROOF(2)3050 MULLED (3) 2x12 HDR (1) JACK EA. END (3) 3050 MULLED(2) 2X10 HEADER(1) JACK EA. END6" W. x 8" D. DROPPEDSOFFITMORNING ROOM45" H. HALF WALL W/WOOD CAPNOTE:FASTEN LVL PLIES W/(3)ROWS OF 16d NAILS AT16" O.C. FROM EA. SIDE(3) 1 3/4" x 18" LVL (FLUSH)NOTE: ADD 6" W/GOURMET KIT. OPT.(3) KING EA. END(4) 2x6 JACKS(4) 2x6 JACKS3rd Car Garage - 12'-0" @ Elevation E - ADDPlotID Length Product Plies Net QtyTSHd3-3 10' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 3 33RD CAR GARAGE - 12'-0" @ ELEVATION E 11 7/8" IJST. / LSL25/32" OSB SUBFL.RIM CONST. - R-20 MIN. 2x8 TR. SILL PLATE W/ A.B.BOTTOM OF TOP CHORD11 7/8" IJST.25/32" OSB SUBFL.VAPOR BARRIERR-49 BLOWN INSULATIONEXTEND SHTG. TO5/8" DRYWALL CLG. (TYP.)CEILING(WINDWASH)MANUF. TRUSSES24" O.C.12PER PLANBATT INSULATION (R-20 MIN.)2x6 TOP & BOTTOM PLATES1/2" DRYWALL WALLS W/ 4 MIL. POLY (TYP.)1/2" BUILT-RITE SHTG TYP.VAPOR BARRIER2x6 STUDS 16" O.C.WALL CONST.VINYL SIDINGHOUSE WRAPR-20 SPRAY FOAM INSULATIONRIM CONST. - R-20 MIN. 1/2" BUILT-RITE SHTG TYP.BATT INSULATION (R-20 MIN.)2x6 TOP & BOTTOM PLATES1/2" DRYWALL WALLS (TYP.)11 7/8" RIMBOARDHOUSE WRAPVAPOR BARRIER2x6 STUDS 16" O.C.ROOF CONST.STD. ENERGY HEEL HT.ASPHALT SHINGLES PER SPECS.WATERGUARD ICE BARRIER AT EAVESVINYL SOFFIT AND ALUM FASCIAWALL CONST.VINYL SIDING7/16" OSB. SHTG.INSUL. CHUTES/EA. TRUSS SPACE15# FELT2x6 SUBFASCIAMIN. 6"1/2" BUILT-RITE SHEATHINGR-20 SPRAY FOAM INSULATION11 7/8" RIMBOARD (NOTE: SEE SHT.1/2" BUILT-RITE SHEATHINGINSTALL WINDWASHAPPROX. GRADEWINDOW FALL PROTECTIONALL WINDOWS, WITH SILLSBELOW 36" A.F.F.TO RECEIVE FALL PROTECTION,WINDOW FALL PROTECTIONALL WINDOWS, WITH SILLSBELOW 36" A.F.F. AND 72"AT REAR WALL (LOOKOUT /WALKOUT)TO RECEIVE FALL PROTECTION,ABOVE YARD GRADEPER R312.2.1PER R312.2.1NOTE: CANTILEVERS TO HAVEMIN. R-30 INSUL. IN FLR. CAVITY 2" "CERTI STUD INSUL (R-10)CANT. I JOIST 1 1/2", W/ STD. RIMADD SQUASH BLOCKS@ ALL POINT LOAD LOCATIONS.A2 FOR SIDE WALL / REAR WALL DTLS.)ADD INVERTED HANGER AT REAR WALL.XP BOARD TO GRADE6" GRAVEL FILL6 MIL POLY / LAPPED 12" 3 1/2" CONCRETE SLAB8" POURED CONC. WALLFDN. WALL CONST."WATCH DOG" WATERPROOFING2 3/8" "WATCHDOG" (R-10)NOTE: R-5 INSUL.REQUIRED AT WALKOUTSIDE WALLS ONLY20x8 CONC. FTG.ORSIZED PER STRUCT.ENGINEERINGMUDROOMBASEMENTOWNER'S W.I.CHALLBEDROOM #2DININGMIN. HEADROOM 8"8'-4"SECOND FLOOR9'-1 1/8"T.O. FOOTING8'-1 1/8"R-20 MIN.INSUL.T.O. PLATET.O. FDTN.FIRST FLR.T.O. PLATE8" (9'-0" AT 9' BSMT.) 6'-8"INSUL.R-49 MIN. HEADROOM 6'-8"OWNER'S BATHLAUNDRYCEILING TEXTURE ONHORIZONTAL PLANE ONLYCEILING CLIPPAINTED TOMATCH WALLABOVE11 7/8" LSL JOISTSSEE FLOOR JOIST LAYOUT11 7/8" LSL JOISTS11 7/8" FLOOR JOISTSCLOSED BOX STAIR(16) EQ. RISERS W/10" TREADSCLOSED BOX STAIR(15) EQ. RISERS W/10" TREADS(16) EQ. R. AT 9'BASEMENTFILTER PAPER O/DRAIN ROCKFILTER PAPER O/DRAIN ROCKHOUSE WRAP CUTTING PATTERN12CUT HOUSE WRAPPER DIAGRAM.CUT UPPER FLAP AT45.FLEX WRAPWINDOW OPENINGWRAP TO SILL OF APPLY 10" FLEXUNDER HEAD INSTALL WINDOWINSTALL JAMBSTRIPS OVERINSTALLED WINDOWHOUSE WRAP FOLDHOUSE WRAP FOLDSTRIP UNDER UPPERINSTALL HEADUPPER FOLDAND TAPE OVERCUT SEAMSOVER HEAD STRIPDROP UPPER FOLDTO SETTING WINDOWAPPY CAULK BEHINDWINDOW FINS PRIORHOLD UPPER FOLD OUT UNTIL FINAL STEPINSTALL, FOLD SIDEAFTER FLEX WRAPHOUSE WRAP FLAPSOVER FLEX WRAPAND TRIM / FASTEN.TAPETAPEWINDOW WRAP.CAP UNDERINSTALL DRIPDOWN EACH SIDE.BEND CORNERS34567895'-4 1/4"8'-0"3 1/2"2'-4 3/4"7'-9"4x4 TRTD POSTSEE A1 FORCOLUMN DETAIL℄SOFFIT / CLG(2) 2X8 BEAMT.O. WDWR-20 SPRAY FOAM INSUL. (+/- 3 1/2") THICK4122'-0"CANT.5'-2"8'-0"3 1/2"2'-7"7'-9"4x4 TRTD POSTSEE A1 FORCOLUMN DETAIL℄SOFFIT / CLG(2) 2X8 BEAMT.O. WDWR-20 SPRAY FOAM INSUL. (+/- 3 1/2") THICK4122'-0"CANT.5'-2"8'-0"3 1/2"2'-7"7'-9"4x4 TRTD POSTSEE A1 FORCOLUMN DETAIL℄SOFFIT / CLG(2) 2X8 BEAMT.O. WDWR-20 SPRAY FOAM INSUL. (+/- 3 1/2") THICK4122'-0"CANT.6'-4"8'-0"4123 1/2"2'-5"T.O. WDW℄8'-9"4x4 TRTD POSTSEE A1 FORCOLUMN DETAILR-20 SPRAY FOAM INSUL. (+/- 3 1/2") THICKSOFFIT / CLG(2) 2X8 BEAM2'-0"CANT.SCALE:A44-APORCH SECTION - ELEV. 'A' , 'AG'1/2" = 1'- 0"SCALE:A44-EPORCH SECTION - ELEV. 'E'1/2" = 1'- 0"SCALE:A44-FPORCH SECTION - ELEV. 'F'1/2" = 1'- 0"SCALE:A44-GPORCH SECTION - ELEV. 'G' , 'GG' , 'GS'1/2" = 1'- 0"SCALE:A42BUILDING SECTION (ELEV. 'A' SHOWN - OTHERS SIM.)1/4" = 1'- 0"LENNAR WILL BE INSTALLING A "PASSIVE RADON READY" SYSTEM.ALL BASEMENT SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BESEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USING POLYURETHANE CAULK ORELASTOMERIC SEALANT AT ALL OPENINGS. ALL SUMP BASKETS WILL HAVE SEALED LIDS.LENNAR WILL INSTALL A 3" GASTIGHT PVC PIPE, AND WILL BE CONNECTED TO THE DRAIN TILESYSTEM. USING A "T" FITTING, INTO THE DRAIN TILE SYSTEM. WE WILL USE THE SHORTEST ROUTETO EXIT THE ROOF SYSTEM, WITH A MAX. OF (2) 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS,THE RADON EXHAUST PIPE WILL BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED"RADON REDUCTION SYSTEM" AT ALL ACCESSIBLE LOCATIONS. ALSO, ALL RADON PIPES WILL BELABELED AT ALL FLOORS FOR FUTURE REFFERENCE.AT ROOF EXIT LOCATIONS, WE WILL MAINTAIN A 10' DISTANCE TO ANY WINDOW LOCATION, 2'BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, INTRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36"VERTICALLY. LENNAR WILL INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUSTFAN ADDITION.RADON NOTE:SCALE:A43HOUSEWRAP DETAIL AT WINDOWN.T.S.SCALE:A41TYP. WALL SECTION3/8" = 1'-0" MICROGFIP GFIP (WP)GASNOTE:NO LIGHT IN BREAKFASTAREA WITH ENLARGEDISLANDTO BSMNTSTAIR LANDINGLIGHTTO 2nd FLR LIGHTSDISPOSAL SWITCH FIREPLACEOPTION3'-0"ELECTRICALSERVICEPANEL6'-0"CAPPEDFIXTURE R.I. EVCGFIP 33 GFIP DISP.3333GFIP (WP)CLG. MNT. FOR G.D.O.GFIP GFIP 3GFIPGFIP ELEVS 'FT' & 'GT'ONLY(2) 2x10 HDR (1) JACK EA END OPTOPT TO 1st FLRSWITCHTO 1st FLRSWITCHWDOPT GFIIN VANITYW/ CFRIGFIP GAS43GFIPGFIPGFIP4 OPTIONALWET BARROUGH-INSUMPDEDICATEDCIRCUIT DEDICATEDCIRCUITGFIP 3OUTLET REQUIREDW/I 8' OF WATERMAIN3GFIP (WP)DUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETDUPLEX OUTLET IN FLOOR220 VOLT OUTLETWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHCEILING MOUNTED INCANDESCENT LIGHT FIXTURERECESSED INCANDESCENT LIGHT FIXTURELIGHT FIXTURE WITH PULL CHAINFLOURESCENT LIGHT FIXTUREEXHAUST FANCHIMESSMOKE DETECTORTHERMOSTATELECTRIC PANELPCSSS43WPELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)GFIPRECESSED INCANDESCENT EYE BALL FIXTURECARBON MONOXIDE DETECTORELECTRIC VEHICLE CHARGER ROUGH-IN (OPTIONAL)LED FIXTURELMULTI-MEDIA JACKEVCMMTCMSDCHPLUGMOLD PMAND HEATING PIPE LOCATIONS AND WOOD FRAMING MEMBERS1. THIS ELECTRICAL PLAN MAY VARY DEPENDING UPON PLUMBINGSUCH AS JOISTS, TRUSSES AND STUDS.GENERAL NOTES ELECTRICAL AND/OR GAS HOOK-UP REQUIREMENTS, THIS INCLUDES2. REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCEBUT IS NOT LIMITED TO WASHER, DRYER, RANGE/COOKTOP,MICROWAVE, OVEN AND/OR ADVANTIUM (WHERE APPLICABLE),DISHWASHER AND REFRIGERATOR.5. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & RECEPTACLESAT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR:REQUIREMENTS OF ALL GOVERNING CODES.AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE4. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS (GFI)AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.TELEVISION.........14"TELEPHONE........14"OUTLETS.............14"SWITCHES...........42"AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)3. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORSGFIP (WP)CLG. MNT. FOR G.D.O.3GFI P 3'-0"ELECTRICALSERVICEPANELEVCGFIP GFIP CLG. MNT. FOR G.D.O.SCALE:A51MAIN FLOOR ELECTRICAL PLAN W/ 2 CAR GARAGE1/4" = 1'- 0"SCALE:A53FOUNDATION ELECTRICAL PLAN1/4" = 1'- 0"SCALE:A53AWALKOUT FOUNDATION ELECTRICAL PLAN1/4" = 1'- 0"SCALE:A52SECOND FLOOR ELECTRICAL PLAN1/4" = 1'- 0"SCALE:A51AMAIN FLOOR ELECTRICAL PLAN W/ 3 CAR GARAGE1/4" = 1'- 0"NOTE:SEE FLOOR PLAN SHEETS& PANEL FOR OPTIONS HEADER1/2" GYPSUM BD.1/2" GYPSUM BD.WIN. OPNG.2x6 HEADER PLATEINSULATE1 1/4" RIM BOARD2x6 DOUBLE TOP PLATE2x6 SILL PLATESUBFL.INSULATE2" SPRAY6'-11 3/8" TO T.O. WIN. R.O.SUBFL. AT 8' CLG. 8'-0" TO SUBFL. AT 9' CLG.1x2 AT EA. SIDE OFWINDOW OPENINGSHEATHINGFOAM INSUL.FLOOR SYSTEM PER PLAN1/2" GYPSUM BD.TRUSS BTM. CHORDTOP PLATEDOUBLE WIN. OPNG.WIN. HDRS.SHEATHING2x6 HDR. PLATET.O. WIN. R.O.6'-11 3/8" TO SUBFL.INSULATEINT/EXT WALL INTERSECTIONINTERIOR WALL CORNER2x6 EXTERIOR WALL1/2" GYPSUM BOARD2x6 R.W. 2x4 R.W. 2x6 EXTERIOR WALL2x2 R.W. INSIDE CORNEROUTSIDE CORNERINSULATE STUDCAVITIES OF ALLCORNERS AND INTERSECTIONSOF OUTSIDE WALLSSIDING2x4 INTERIOR WALL 2x4 BACKINGAT MID HGT.2x4 INT. WALLSHEATHING(EXT. FIN. MAY VARY PER PLAN)PER PLANEXT. MAY VARYSHEATHING12'-0"PLYWD. DIM.ALUM. SOFFITW/ALUM.2 x 6 SPF1/2" OXBOARD SHEATHINGGABLEEND TRUSS(WHERE APPL.)2x6 FOR LOOK OUTSUSE SCRAP 2x4 ORNOTE:ENG'DFASCIA2x4 INT. WALLBOARD1/2" GYPSUM5/8" GYPSUM BD.2x4 DOUBLETOP PLATE2x6 BACKINGBOTTOM CHORDOF TRUSSINT WALL2x2 NAILER3/4" PLYWOOD1/2" GYP. BD.FIRE STOP5/8" GYP. BD.I-JOISTCABINETDOUBLE TOP PLATE1'-0"1'-3"3"5/8" GYP. BD.1/2" GYP. BD.UPPERPER PLANHANGER(2) MICROLAM BEAMSHANGER1/2" GYPSUM BD.SUBFLOORNOTE:FOLLOW MFG'S NAILINGPATTERN FOR HANGERFLOORSYSTEMPER PLANFLOORSYSTEMPER PLANFLOOR SYSTEM PER PLAN1/2" GYPSUM BD.SUBFLOOR(2) 2 x HEADERS1/2" OSBDOUBLE TOP PLATESILL PLATESILL/ TILT TO OUTSIDEHEADER(1) 2X6 TRIMMER U.N.O. VARIES 8'-1 1/8" or 9'-1 1/8" TYPICAL VARIES 7'-0" OR 8'-0" (MAIN FLOOR) / 6'-11 3/8" (2ND FLR.) (R.O.)(R.O.)ON FLOOR PLAN(REFER TO PLAN)FOR WATER DRAINAGERUN TRIMMERS TOBOTTOM OF HEADER(SEE PLAN)BOTT. PL.10"2x12 STRINGERS3'-0"10"7 3/4" MAX.(3) 2x12 STRINGERS5/8" TYPE "X" GYP.AT ENCLOSED USABLESPACE (TYPICAL)UNLESS NOTED OTHERWISE IN CONSTR. WORK ORDERPARTICLE BOARD TREADS & RISERS3"6 1/2" W. x 3/4" T.WOOD CAP5/8" TYPE "X" GYP.AT ENCLOSED USABLESPACE (TYPICAL)ALLOW 6'-8" MIN. HEADROOMNOTE:REFER TO SELECTIONS FOR REFER TO PLAN OR WORK ORDER FOR RAIL AND FINISH TYPE(S)NOTE: THIS DETAIL IS FOR FRAMING PURPOSES ONLY4"MAX.RAIL TYPE3/4" PLYWOOD1 1/4" RIMBOARDSUBFLOORFACE OF RISER3/4" PLYWOOD1 14"7 3/4" MAX.11 14"FLOORSYSTEMPER PLANMAX.MAX.1 14"11 14"MAX.MAX.2x4 TO EXTEND 1 1/2"BEYOND 2x AT EA. ENDCAULKNOTE:5 DEG.2 x W/BEV. TOP"Z" FLASHINGSMOOTH FINISH 2x4EXT. FINISH PER PLANSEE PLANVARIESROUGH OPENINGROUGH OPENINGSUBFLOORCRIPPLEHEADER PLATEDOUBLE TOP PLATE9'-1 1/8" OR 8'-1 1/8" TYPICAL STUDSNOTE: THIS DETAIL IS FOR FRAMINGPURPOSES ONLY, REFER TO SPEC'S. BOX NEWELSTARTER1 3/4" RIM BD.1/2" GYP.SUBFLR.PER PLANFLR. SYSTEM3'-0" FROM FIN. FLR.FOR RAIL & FINISH TYPES TREADPOSTSTONE CAPOR ROWLOCK BRICKFLASHING - CONT.CAULKSHEATHING15# FELT1" AIR SPACESTUD WALLSIDING PER PLANSLOPED TO DRAINSHEATHING ONCEDAR 5/4x BLOW UP DETAIL1 1/8"CAULK"Z" FLASHING"Z" FLASHING4"MINIMUM FINISH MTR'L.PER PLANPER PLANCAULK2x6 FRAMINGFINISH MTR'L.PER PLANWIN. UNIT DIM.14"WIN. ROUGH OPENINGSHEATHINGWINDOW UNITGYPSUMSPRAY FOAM SIDINGTRANS.INSULATIONTRIMSTONE/BRICK CAPSLOPED TO DRAIN(FOR STONE CAP)CAULKTO BACK OF SILLSHEATHING15# FELT1" AIR SPACEFLASHING - CONT.FLASHING - CONT.(FOR BRICK CAP)TO BACK OF SILL36"24"4"30 1/2"(2) USP B88 CLIPS W/FRAMING HEIGHT FOR BOX PIER FINISH WIDTH IS PER PLAN(6) 3/8" x 1" LAG SCREWSTOP RAIL OF RAILING1/2" OSB SHEATHINGINSTALL ICE/WATER SHEILDBEHIND B88 CLIPS2X6 BACKER AT MID POINTBOTTOM RAIL OF RAILING24" IS MOST TYPICAL WIDTH2'-0"2x6 SPF MIN. ICE BARRIERVERT. TO ROOFW/ R19 BATT INS.2x6 STUD WALLON 4 MIL POLY1/2" GYPSUM BD.SOFFITSIDING PER PLANSHINGLES, 15# FELT, 48# BASESHEATHINGTRUSS BOT. CHORD5/8" GYPSUM BD.INSULATION BAFFLES (48" L.)ENG'D TRUSSES AT 24" O.C.R-44 INSULATIONDBL. TOP PLATEON 4 MIL POLYROOF VENTS AS REQUIREDSHEATHINGICE BARRIER6"MIN.HEEL HGT.ICE BARRIER TO END THIS POINTNOTE: ICE AND WATER SHIELD TO RUNENTIRE LENGTH OF ALL VALLEYS2 ROWS OF 24" TO INSURECOVERAGE PAST PLATE LINEEXTEND SHEATHING1 1/4" PAST END OF TRUSSFOR 6/12 PITCH ROOF.REDUCE OVERLAP PERSTEEPER PITCH TRUSSES.OVERLAP W/ FASCIAICE / WATER SHIELD5/8" FIRE-RATEDGYP. BOARDEXTERIORSHEATHINGWRB CONT. ONVERTICAL &HORIZONTALPLANES ATTUCKUNDER,TAPE ALL SEAMSR-20 SPRAYFOAM AT RIM6" DIA. R-4.2 INSULATEDFLEX-DUCT, HELD TIGHTTO FLOOR ABV.TYP. EXTERIORWALL: 2x6 STUDFRAMING W/ R-21BATT. INSULATIONTHERMOPANR-19 MIN. SPRAYFOAM INSUL.PER TABLE R402.1.1WRB CONTINUOUS ONVERTICAL AND HORIZONTALPLANES AT TUCKUNDER,TAPE ALL SEAMSTUCKUNDER FLOOR CAVITIESW/O HVAC BLOWN FULL W/ 11-7/8"FIBERGLASS L-77 INSULATIONI-JOIST FLRSYSTEMGARAGEHOUSEHOUSEELASTOMERICCAULK ATCORNER(BY INSULATORS)8" MIN.PVC SHOWER PAN LINER, DONOT CUT. EXTEND UP WALL 8"MIN.CEMENT BOARD, OVER LINERCERAMIC TILEWOOD SUBFLOORGROUT SOLID W/ MORTARCERAMIC TILE, SLOPED1" VERT. TO DRAIN2-PIECE SHOWER DRAINSYSTEMTILE SHOWER WALLAND DRAIN DETAILTILE SHOWERCERAMIC TILE W/ BULLNOSEDEDGE AT LIPCEMENT BOARD, OVER LINERWOOD SUBFLOOR(2) 2x4 SLEEPERSAT 8" O.CPVC SHOWER PAN LINER, DONOT CUT. CONTINUE OVERPLATFORM 12" MIN.GROUT SOLID W/ MORTARCERAMIC TILE, SLOPED1" VERT. TO DRAINCERAMIC TILEPLATFORM FLOOR1'-0" MIN.PLATFORM DETAILTILE SHOWERCEMENT BOARD OVER (2) 2X4SLEEPERS AT 8" O.C.TILE FLOORWOOD SUBFLOOR(2) 2x4 CURBCERAMIC TILE W/BULLNOSED EDGEOWNER'S BATHROOMSERENITY SHOWERCURB DETAILNON-BEARINGN/AN/A1FLASHING DETAIL3"= 1'-0"2NAILER DET.1"= 1'-0"N/A3FLUSH BEAM1"= 1'-0"4DROP'D. BEAM1"= 1'-0"5EAVE/RAKE1"= 1'-0"8STONE SILL DETAIL1" = 1'-0"91011M. FLR. WIN. HDR.1" = 1'-0"12UPPER FLR. WIN. HDR.1" = 1'-0"13TYP. STUD LAYOUT1" = 1'-0"1516DOOR FRAMING1" = 1'-0"17WINDOW FRAMING1" = 1'-0"19RAIL DETAIL1" = 1'-0"201x2 NAILER @ WINDOW3" = 1'-0"21TRIM DETAIL3" = 1'-0"14PIER / RAIL DTL.3/4"" = 1'-0"6SOFFIT DETAIL1"= 1'-0"7STONE CAP1"= 1'-0"18STAIR FRAMING DETAIL1/2" = 1'-0"22TYPICAL OVERHANG DETAIL1" = 1'-0"23FLOOR ABV. GARAGE INSUL. DETAIL1" = 1'-0"24SERENITY SHOWER OPTION DETAILS1 1/2" = 1'-0" KITCHEN3'-9"17'-0"8'-0 1/2"5 1/2"4'-9 1/2" 10'-0" 4'-9"8'-0 1/2"5 1/2"5 1/2"6'-6"(3) 2x12 HDR (1) JACK EA. END 6068 S.G.D.TRUSSES ABOVE AT 24" O.C.PRE-ENGINEERED ROOF(2)3050 MULLED (3) 2x12 HDR (1) JACK EA. END (3) 3050 MULLED(2) 2X10 HEADER(1) JACK EA. END6" W. x 8" D. DROPPEDSOFFITMORNING ROOM45" H. HALF WALL W/WOOD CAPNOTE:OMIT ALL UPPERCABINETS AT THISLOCATION W/MORNING RM.FASTEN LVL PLIES W/(3)ROWS OF 16d NAILS AT16" O.C. FROM EA. SIDE(3) 1 3/4" x 18" LVL (FLUSH)NOTE: ADD 6" W/GOURMET KIT. OPT.3"RADIUS10" O.H.6" RADIUS10" OVERHANG6" RADIUS3" RADIUS4'-3"4'-0" 5'-10 1/2"REFR(3) KING EA. END(4) 2x6 JACKS(4) 2x6 JACKS14121ST FLR LINEROOF VARIES PERELEVATION12(TYP.)12(TYP.)9'-1 1/8"T.O. FND1ST FLRT.O. PL.2ND FLR12" RAKE O.H. AT12" O.H. AT SIDEREAR ELEV.ELEV'S.4:124:12ROOFVENTR-21 INSULATION1st FLR9'-1 1/8"8'-4" OR 9'-0"8" CONCRETEWALL (TYP.)BTM OF FTGTOP OF FTGTOP OF FOUNDATION8"GRADE2" RIGIDINSULATION R-10MORNING ROOM1st FLR PL.TYP. RIM DETAIL,SEE A4 SHEETTYP. EXT. WALLCONSTRUCTION,SEE A4 SHEETR-49 INSUL.AT CEILINGWATERPROOFINGPER CURRENTCODE4" WEEP TUBESEVERY 6' O.C. IN16" WIDE FTG.VERT. RE-BAR PERCODE4" CONC. SLAB OVER 6MIL VAPOR BARRIERAND 8" GRAVEL BASE7" HEEL HT.16'-9"STORAGECONCRETEW8 x 18 x 16'-0" STL. BEAMSYSTEM ABOVEPRE-ENGINEERED FLOOR4"X8"X8 1/4" H. BEAMPKT. (TYPICAL)42"x42"x12"D. CONC. FOOTINGW/ (5) #4 BOTT. EA. WAY3'-9"10'-0"SUMP PIT DISCHARGE(4) #4 VERT. IN CONC.WALL BELOW BEAMBEARING (TYP.)(4) #4 VERT. IN CONC.WALL BELOW BEAMBEARING (TYP.)PROVIDE SQUASHBLKNG @ WEB OFSTL BM @ BEARINGLOCATIONS (TYP.)ROTATE OUTLET 90^ ATHALF WALL, ABV.BACKSPLASHNOTE: SEE FOUNDATION PLAN FORBASEMENT ELECT. INFO.DISP.EQ.EQ. 2'-9 1/8"FAN R.I. CAPPEDLLLLLLGFIP GFIP GFIP LT/ FDN.EL.= MINUS 5'-6"(9' BSMT.)T/ FDN.W8 x 18 x 16'-6" STL. BEAMW/ (4) 2X8 JACKS EA. END2X8 STUD KNEE WALL W/ STUDSAT 16" O.C. ON 4'-0" HIGH STEMFNDTN WALL10'-0"4636 SLIDER8'-4 1/2"8'-4 1/2"(2) 2x10 HDR W/3'-9"SYSTEM ABOVE PRE-ENGINEERED FLOOR SUMP PIT DISCHARGE(4) #4 VERT. IN CONC.WALL BELOW BEAMBEARING (TYP.)PROVIDE SQUASH BLKNG @ WEBOF STL BM @ BEARINGLOCATIONS (TYP.)42"x42"x18"D. CONC. FOOTINGW/ (5) #4 BOTT. EA. WAY(1) 2x6 JACK16'-9"T/ FDN.EL.= 0'-0"EXTEND FULL HT.CONC. WALL TO REARCORNER8"1 1/2"7 1/4"EL.= MINUS 4'-10"(MINUS 5'-6" AT9' BSMT. OPT.)8'-6"8'-6"10'-0"3'-9"5'-3"4'-9"(3) 3050 MULLED(2) 2x10 HDR6068 S.G.D. (2) 2x12 CONT. (1) JACK EA. END (1) JACK EA. ENDSYSTEM ABOVE PRE-ENGINEERED FLOOR SUMP PIT DISCHARGEW8 x 18 x 16'-8" STEEL BEAMW/ (6) JACKS EA. END42"x42"x18"D. CONC. FOOTINGW/ (5) #4 BOTT. EA. WAYPROVIDE SQUASH BLKNG@ WEB OF STL BM @BEARING LOCATIONS (TYP.)17'-0"INSIDE FACE OF FNDTN.WALL BELOWW/ STUDS AT 16"O.C.2x6 BEARING WALL 5 1/2"5 1/2"1 1/2"T/ FDN.EL.= MINUS 8'-0"EL.= MINUS 8'-0"T/ FDN.(MINUS 8'-8" AT9' BSMT. OPT.)(MINUS 8'-8" AT9' BSMT. OPT.)2(TYP.)1T/PL.T/PL1st FLR5'-6"T/FTG3'-6"T/FDTN9'-1 1/8"12(TYP.)11ST FLR LINE41212(TYP.)T/PL.T/PL1st FLR8'-8"T/FTG4'-0"T/FDTN9'-1 1/8"12(TYP.)1ST FLR LINE41217'-7 1/4"R-21 INSULATION1st FLR9'-1 1/8"8'-4" OR 9'-0"BTM OF FTGTOP OF FTGTOP OF FOUNDATION8"GRADE2" RIGID INSULATIONR-10MORNING ROOM1st FLR PL.TYP. RIM DETAIL,SEE A4 SHEETTYP. EXT. WALLCONSTRUCTION,SEE A4 SHEETR-49 INSUL. ATCEILINGWATERPROOFINGPER CURRENT CODE4" WEEP TUBESEVERY 6' O.C. IN16" WIDE FTG.VERT. RE-BAR PERCODE4" CONC. SLAB OVER 6MIL VAPOR BARRIERAND 8" GRAVEL BASE7" HEEL HT.12R-20 INSULATION MIN.41st FLR9'-1/8"8'-4" OR 9'-0"BTM OF FTGTOP OF FTGTOP OF PLATE8"GRADE2" RIGIDINSULATION R-10MORNING ROOM1st FLR PL.TYP. RIM DETAIL,SEE A4 SHEETTYP. EXT. WALLCONSTRUCTION,SEE A4 SHEETR-49 INSUL. ATCEILINGWATERPROOFINGPER CURRENT CODE4" WEEP TUBESEVERY 6' O.C. IN16" WIDE FTG.4" CONC. SLAB OVER 6MIL VAPOR BARRIERAND 8" GRAVEL BASE4'-0" 7" HEEL HT.NOTE W/ FINISHED BASEMENT:AT FINISHED BASEMENT, DELETEWALL BELOW STL. BEAM AND BUILDSOFFIT 8"W. x 12"D. ADD CARPET,CHANGE LIGHT TO (2) LEDS, AND ADD(3) OUTLETS.SCALE:A71FULL FOUNDATION PLAN1/4" = 1'- 0"SCALE:A72LOOKOUT FOUNDATION PLAN1/4" = 1'- 0"SCALE:A73WALKOUT FOUNDATION PLAN1/4" = 1'- 0"SCALE:A74SIDE ELEVATION1/8" = 1'- 0"SCALE:A75REAR ELEVATION1/8" = 1'- 0"SCALE:A76SIDE ELEVATION1/8" = 1'- 0"SCALE:A77LOOKOUT ELEVATIONS1/8" = 1'- 0"SCALE:A78WALKOUT ELEVATIONS1/8" = 1'- 0"SCALE:A79ROOF PLAN1/8" = 1'- 0"SCALE:A710WALL SECTION-FULL FOUND.1/2" = 1'- 0"SCALE:A711WALL SECTION-LOOKOUT1/2" = 1'- 0"SCALE:A712WALL SECTION-WALKOUT1/2" = 1'- 0"SCALE:A713MAIN FLOOR PLAN1/4" = 1'- 0"SCALE:A714MAIN FLOOR ELECTRICAL PLAN1/4" = 1'- 0"Secure door closed until deck isconstructed with a separate permit. Sheet:1of4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformaƟonLack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.*Conventional construction code minimum for usewith A3 only. See the Weyerhaeuser TJI®Specifier's Guide, #TJ-4000, for A3.1-A3.3installation specifications and applications.Plate nail - 16d (0.135" x 312")at 16" on-center*Floor panel nail - 8d (0.131"x 212") at 6" on-center*Toe nail - 10d (0.131" x 3")at 6" on-center*114" TimberStrand®LSL or118" TJ® rim board.*When sheathing thickness exceeds 78",trim sheathing tongue at rim boardA3A3.2A3.1 A3.3Load bearing or braced/shear wallabove (must stack over wall below)Blocking panel: 118" TJ® Rim Board, 114"or 112" TimberStrand®LSL or TJI® joist.Web stiffeners requiredon both sides at B1Wand B2W ONLYB1WB1B2B2W116"2x4 minimumsquash blocksBlocking panels may be required with braced/shearwalls above or below — see detail B1Use 2x4 minimum squash blocks totransfer load around TJI® joistCSLoad from above2x4 minimumsquash blocks116"BlockingpanelEnd of joistsat centerlineof supportB4Load bearing or shear wallabove (must stack overwall below when present)2'TJI® JOIST2"2x6 (min.) solid sawn or 4 12" wideTimberstrand® LSL rim board, full lengthin bay and tight to each joist flange. Connectto plate with 8d (0.113" x 2 38") nails at 6"on-center.2416 span rated sheathing (716" Min.).Attach with 8d (0.113" x 2 38") nails at6" on-center along panel edges and infield. Use pressure treated plywoodfor ground level cantilevers.E1 ALTTimberstrand ® LSL rim boardto match TJI® depthWARNINGJoists are unstable until braced laterally,Safety bracing required during installation.Lateral load transfer for this detail is180 PLF (pounds per lineal foot).Additional connections may be requiredto transfer lateral loads from wall above.8" diameter maximum hole for 1178" -16" deep blocking panels; 6" diametermaximum for blocking panels 912"deep or shorter than 12" long.Do not cut flanges.E1E1WWeb stiffenersrequired on bothsides at E1W ONLY118" TJ® Rim Board or114" or 112" TimberStrand® LSL.Nail with 10d (0.131" x 3")nails, one each at top andbottom flange.Variable slope joisthanger. Beveled webstiffener required eachside.LSTA24 (Simpson Strong-Tie or USP StructuralConnectors) strap with twelve 10d (0.148 x 112")nails required at H5S with slopes greater than 3:12H5H5SStrap nails:Leave 238" minimumend distanceAdditional blockingmay be requiredfor shear transfer.H5S is allowed only with joist depths < 16''_LOLDouble joistmay be requiredwhen L exceedsjoist spacing2x_ overhang. Notcharound TJI® joist topflange.Blockingas requiredEnd wallR5Beveled web stiffeners required onboth sides. Cut to match roof slope.2x4 block for soffit supportBIRDSMOUTH CUT allowed at low end of joist only 2'-0"maximumTJI® joist flangemust bear fully onplate.Birdsmouth cutmust notoverhang insideface of plate.R92x4 one side. Use 2x6 ifjoist spacing is greater than24" on-center.10d (0.128" x 3")nails at 8"on-centerBeveled 2x4 blockBeveled web stiffenerson both sidesBIRDSMOUTH CUT allowed at low end of joist only4'-0"minimum2'-0"maximumR14Strap nails:Leave 238" minimumend distanceDouble beveled bearing platewhen slope exceeds 14:12LSTA18 (Simpson Strong-Tie® or USPStructural Connectors®) strap withtwelve 10d (0.148" x 112") nailsAdditional blockingmay be required forshear transferWeb Stiffener required onboth sides at R14W ONLYWR7R7Web stiffenersrequired on bothsides at R7W ONLYBeveled bearingplate required whenslope exceeds 14:12INTERMEDIATE BEARINGBlocking panels or shear blocking may bespecified for joist stability at intermediate supportsR7STwist strap and backer block required atR7S with slopes greater than 3:12. SeeNailing Requirements at Bearing inWeyerhaeuser Installation Guide for Floorand Roof Framing, TJ-9001.R7S is allowed only with joist depths < 16''_NAILING FOR TOP & BOTTOM PLATE TO SHEATHING & CEILING/ROOF MEMBERSSHEATHING NAILING(16d PNUEMATIC NAILS)NAILS/FT16" o.c.24" o.c.NON-HURRICANE PRONE REGIONS 3 4 6HURRICANE PRONE REGIONS 4 6 8120 MPH WIND AREA 5 7 10CEILING/ROOF MEMBER SPACINGP5L13 P6Header to columnHeaderColumnColumn to Top PlateFraminganglesas requiredTrimmerStud (s)Plate widthmust equal wallthickness toprovide lateralbracing. (Platenot required ifheader widthequals the wallthickness.)Trimmerstud (s)Doubletop plateFraminganglesas requiredSolid blocking isrequired if columnand trimmer studsdo not extend tosill plateBlockingpanel asrequiredTrimmerstud (s)Framinganglesas requiredRimboardSill PlateSoleplateColumnColumn to Bottom PlateA notch and hole shall not occurin the same cross sectionMaximum diameter:*138" for 312" thick walls*2316" for 512"-1114" thick wallsMaximum notch:One hole may be cut anywwhere along the length ofthe stud or column but must be at least 58" from the edge.One notch may be cut anywhere except themiddle 13 of the length of the stud or column.*78" for 312" thick walls*138" for 512"-1114" thick walls58" Minimumedge distanceL/3L/3L/3Allowable Holes and Notches*Note: Field skewableframing angles requiredfor sloped top plateconnectionsWB2Connection of double top plate to outlooker must bedesigned to tranfer lateral load to roof.Connect outlooker to double topplate with angle clip (565 lbs min.for Load 1) at 24" o.c.2x_ outlookerContinuous tall-wall framing(from sill plate to top plate)4" o/c nailingrequired fromsheathingto outlookerBlocking betweenoutlookers asrequiredConnect outlooker to trusswith (2) 16d nails for 2x4,(3) 16d nails for 2x6 or 2x82' maxWB3Loads must be trackedto foundation by designerof recordTrusses by othersat 24" on centerConnect truss todouble top platewith one angleclip (545 lbs min.for Load 2) at24" o.c.Gable end wall2x_ solid sawn angle braces toconnect double top plate to roof @ 2'-0"o.c. along length of wall fit snug betweenthe two bays. Connect with (3) 16d nails.2x_ solid sawn connected to topof bottom chord with (3) 16d nails at2'-0" o.c. along length of wall, back 8'-0"Wall bracing is necessary if double top plate is not attacheddirectly to the roof/floor diaphragm.25° to45°Member OrientationPlate width must equal wall thicknessto provide lateral bracing (plate notrequired if header equals wall thickness)MULTIPLE MEMBER CONNECTIONS FOR POINTLOADED COLUMNS2 PLY 3 PLY 4 PLYUSE 16d (0.131" x 314") PNEUMATIC NAILS4 PLY ALTERNATE: 2 ROWS, 12" DIAMETER BOLTS AT 8" ON-CENTERMULTIPLE MEMBER CONNECTION FOR NON POINT LOADEDCOLUMNS2 PLY, USE (2) ROWS 16d PNEUMATIC NAILS AT10" O.C.3 PLY'S AND GREATER, USE (2) ROWS 16d PNEUMATIC NAILS (EACH PLY) AT 8" O.C.- STAGGER 2" PER PLYDO NOT cut, notch or drillholes in headers or beamsexcept as indicated inillustrations and tables.DO NOTcut or notch flange.DO NOTcut holes in cantileverreinforcement.112" hole may be cutanywhere in web out-side of hatched zoneMin. distance from Table ANo field cutholes inhatchedzonesMinimum distance from edge of hole to inside face of nearest end supportminimum(applies to all holesexcept knockouts)Table A - End Support6"6"1L12 x D1DDL2 x Lminimum226"6"2ALLOWABLE HOLES - TJI® Joists1.3E TimberStrand®LSL allowed hole zoneddMicrollam®LVL andParallam® PSLallowed hole zonemiddle 13 span1.3E TimberStrand®LSL hole zoneMicrollam®LVLand Parallam® PSLhole zone2 x diameter of thelargest hole (minimum)d13 depth1"2"134"Maximum RoundHole SizeHeader or Beam Depth438"714"- 20"512"See illustration for Allowed Hole ZoneOther Trus Joist® Headers and Beams1.55E TimberStrand®LSL Headers and BeamsALLOWABLE HOLES - Headers and Beams13 depth2 x diameter of thelargest hole (minimum)8"See illustration for allowed hole zone1114"-11 78"14"-16"914"-912"358"458"3"No holes in headers or beams in plank orientation.Round holes onlyGeneral NotesGeneral NotesNo holes in headers or beams in plank orientation.Allowed hole zone suitable for headers and beams with uniform loads only.Round holes onlyNo holes in cantilevers.Allowed hole zone suitable for headers and beams withuniform and/or concentrated loads.Maximum RoundHole SizeHeader or Beam Depth8"Allowed hole zoneMin. distance from Table BDo not cut holes largerthan 112" in cantilever6"Closely grouped roundholes are permitted ifthe group perimetermeets requirements forround or square holes.10'-0" 11'-6"3'-0"1'-0"1'-0" 1'-6" 9'-0"9'-0"6'-6"4'-6"1'-0" 1'-0"1'-0"3601'-0"12'-0"17"13"15'-6"15'-6"SQUARE OR RECTANGULAR HOLE SIZEMinimum distance from edge of hole to inside face of nearest intermediate or cantilever support16'-6"16'-0"21'-0"20'-6"18'-0"17"17'-0"For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be locatedat the center of the joist span provided that no other holes occur in the joist.Distances are based on the maximum uniform loads from current Trus Joist specifier's guides. For other load conditions or holeconfigurations use Forte® software or contact your Weyerhaeuser representative.15"8"10"6"4" 12"17"15"12"10"8"6"4"16'-0"15'-6"Holes may be located vertically anywhere within the web. Leave 18" of web (minimum) at top and bottom of hole.Knockouts are located in web at approximately 12" on-center; they do not affect hole placement.1'-0"1'-0"1'-0"1'-0"Rectangular holes based on measurement of longest side.18"20"1'-0"5605603603601'-0"1'-0"1'-0"1'-0" 1'-6"1'-0"2'-0"3'-0"3'-0"6'-0"6'-0"12'-0"5'-6"16'-6"11'-0"15'-0"10'-0"6'-0"9'-0"6'-0"3'-0"1'-6"4'-0"1'-0"1'-0"1'-0"1'-0"16'-6"18'-0"16'-6"14'-0"8'-6"7'-0"9'-0"11'-6" 16'-6"12'-6"14'-6"19'-6"17'-6'19'-0"20'-0"19'-6"10'-0"17"11'-0"13"10'-6"ROUND HOLE SIZETable B - Intermediate or Cantilever Support11'-0"10'-0"15'-0"13'-6"4'-0" 8'-6"2'-6"2303'-0"1'-0"1'-0"1'-0"1'-0"3'-0"3'-0"1'-0"1'-0"4'-0"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"1'-0"16"14"2305603601'-0"1'-0"1'-0"2305602103601'-0"1'-0"1'-0"1'-0"1178"1'-0"2303601102105602'-0"1'-0"1'-6"3602101103'-0"1'-0"1'-0"9'-6"5'-6"1'-0" 2'-6"1'-0"1'-0"1'-0"1'-6"2'-6"3'-0"1'-0"1'-0"1'-6"2'-0"1'-0"5'-6"5'-6"3'-6"11'-0"10'-0"4'-0"7'-0"6'-6"6'-6"10'-6"13'-6"12'-6"6'-0"9'-6"3'-6"8'-6"6'-0"2'-6" 5'-0"4'-0"1'-0"4'-6"7'-0"2'-0"8'-0"5'-6"2'-0"1'-6"4'-6"4'-0"9'-0"10'-0"11'-0"4'-6"12'-0"8'-6"9'-0"8'-6"6"3"1'-0"1'-0"1'-0"1'-0"1'-0"2'-6"2'-6"912"TJI®2101102"2'-0"2'-0"18"20"1'-0"3605605603601'-0"1'-0"1'-0"5601'-0"4"4"3'-6"3'-6"612"8'-0"7'-6"878"11"1'-0" 2'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"8"10"1'-0"10'-0"5'-0"11'-0"5'-0"1'-0"2'-0"7'-0"7'-0"5'-0"12"7'-6"15"7'-6"3'-6"2'-0" 4'-6"4'-6"2'-0"1'-6"3'-6"2'-6"1'-0"1'-0"1'-0"3'-0"1'-0"1'-0"2'-0"4'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"2'-0"1'-0"3'-0"3'-0"1'-0"1'-0"13'-0"6'-0"2'-0" 10'-0"10'-6"13'-6"12'-0"11'-0"14'-6"13'-0"1'-0"3'-6"2'-0"5'-0"9'-0"7'-6"1'-0"5'-0"4'-0"2'-6" 6'-6"4'-6"10'-0"9'-0"13'-6"16'-0"14'-6"13'-6"12'-6"15'-0"14'-0"10'-0"12'-0"11'-0"10'-6"10'-0"8'-6"3'-6"5'-0"1'-0"6'-0"9'-6"5'-0"10'-6"5'-6"3'-0"2'-6"8'-0"8'-0"7'-0"12'-0"9'-0"9'-6"2'-0"6"1'-6"1'-0"1'-0"3"1'-0"3'-0"2'-6"2'-0"1'-6"2"1'-0"1'-0"1'-0"1'-0"1'-0"4"4'-0"3'-6"4"612"7'-6"6'-6"11"878"10'-0"12'-0"11'-6"11'-0"10'-0"5'-0"6'-6"4'-0"2'-6"11'-0"9'-6"8'-0"3'-0"8"4'-6"10"13'-6"14'-6"14'-6"14'-0"12'-6'11'-0"15"12"13"11'-0"11'-0"SQUARE OR RECTANGULAR HOLE SIZE13"6'-0"7'-0"ROUND HOLE SIZE1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-6"2'-0"2'-0"1'-6"1'-6"1'-0"1'-6"1'-0"2'-0"2'-6"1'-6"56016"14"1'-0"3602102305601'-0"1'-0"1'-0"2102301101'-0"1'-0"1'-0"1178"912"1102303602101'-0"1'-0"1'-6"1'-0"1102303602101'-0"1'-6"1'-6"1'-0"8'-0"3'-0" 4'-0"1'-6"1'-0"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"1'-0" 1'-0"1'-6"8'-0"5'-6"2'-6"3'-0"6'-6"3'-6"4'-0"9'-0"3'-6"4'-0"3'-0"6'-0"7'-0"5'-6"1'-6"2'-0"3'-0"2'-0"2'-0"3'-6"2'-6"2'-0"2'-0"2'-6"3'-0"2'-6"4'-0"3'-6"3'-0"3'-0"5'-6"6'-6"7'-0"6'-0"3"JOISTDEPTHTJI®2" 4" 878"11"1'-6"2'-0"1'-6"2'-6"2'-0"2'-0"3'-6"2'-6"1'-0"1'-6"1'-0"1'-0"1'-6"1'-0"1'-0"3'-0"2'-6"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"1'-6"1'-0"5'-6"4'-6" 8'-0"4'-0"2'-6"1'-0"1'-0"4'-0"2'-0"2'-0"5'-0"2'-0"1'-6"2'-0"3'-0"2'-6"2'-0"9'-6"8'-0"9'-0"8'-0"10'-0"7'-0"6'-6"9'-0"9'-0"8'-6"8'-0"7'-0"6'-0"6'-6"2'-0"3'-6"2'-6"2'-6"2'-6"4'-6"3'-6"3'-0"3'-6"3'-0"2'-6"2'-6" 3'-6"5'-0"4'-6"4'-0"7'-6"7'-0"6'-6"6'-0"3"2" 4" 11"878"612"5'-6"5'-0"5'-6"6'-0"3'-0"3'-0"4'-6"2'-6"2'-0"2'-6"1'-6"4'-6"1'-0"1'-6"3'-6"5'-6"2'-6"2'-6"612"4'-6"5'-0"5'-0"5'-6"5'-0"5'-6"6'-6"4'-6"3'-6"4'-0"4'-0"7'-0"3'-6"3'-0"6'-0"7'-0"6'-6"5'-0"3'-6"3'-6"5'-0"3'-0"2'-6"2'-6"2'-0"5'-0"1'-6"1'-6"4'-0"6'-0"3'-0"2'-6"5'-6"5'-6"6'-6"5'-0"4'-0"4'-6"5'-0"7'-6"4'-0"3'-6"6'-6"7'-6"7'-0"5'-6"5"5"7"7"1'-6"2'-6"3'-0"5"4'-6"5'-0"2'-6"3'-0"6'-6"5'-6"1'-0"5'-6"3'-6"3'-6"3'-6"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"5'-6"7"4'-6"3'-0"2'-0"3'-6"4'-0"4'-0"1'-0"6'-6"6'-0"5'-6"7'-6"2'-6"8'-6"5'-0"7"5"5'-6"6'-6"3'-6"2'-6"5'-6"4'-0"4'-0"1'-6"7'-0"5'-6"5'-0"7'-0"2'-6"8'-0"7'-6"4'-6"4'-0"6'-6"8'-0"11'-0"6'-0"9'-6"9'-0"10'-0"11'-0"5'-6"7'-6"8'-6"10'-0"6'-0"7'-0"7'-0"5"1'-0"1'-0"1'-0"1'-0"7"1'-0"1'-0"1'-0"1'-0"5" 7"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"3'-0"4'-0"5"1'-0"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"7" 5"1'-0"1'-0"3'-6"1'-6" 6'-6"4'-0"6'-0"8'-6"7"JOISTDEPTHEXTERIOR DECK ATTACHMENTStructural exterior sheathingSee fastenertable below. Maintain2" distance (minimum) fromedge of ledger to fastener.LAFlashingTreated 2x_ledger118" TJ® Rim Boardor 114" or 112"TimberStrand®LSL.(1) Corrosion-resistant fasteners required for wet-service applications.(2) Allowable load determined in accordance with ASTM D7672.(3) 118" TJ® Rim Board is allowed with joist depths < 16" only.(4) Maximum 12" shimmed air space.Fastener Allowable Load (lbs/bolt)48012" lag bolt118" TJ® Rim BoardRim Board Material1 14" TimberStrand® LSL1 12" TimberStrand® LSL61067569512" Through bolt72572512" Through boltwith Air Space615(2)(3)(4)_Load bearing wall above(must stack over wall below)Web stiffeners required onboth sides at B5W ONLYB5B5WPer IRC R502.7,blocking required ateach intermediatesupport in seismicdesign categoriesD0, D1, and D2.Blocking panels may be required with shearwalls above or below — see detail B1TJI® 560 floor joistTop ViewNAILING AT BEARING (FLOOR)134" minimum end bearingsingle-family applicationsTJI® Joist to Bearing Plate118" TJ® Rim Board,114" or 1 12" TimberStrand® LSL. or TJI® 110 rim joist:One 10d (0.131" x 3") nail intoeach flangeTJI® 210, 230, and 360 rim joist:One 16d (0.135" x 312") nail intoeach flange.With depths > 16", use TJI® 360 rim joist.Shear transfer: Connections equivalentto floor panel nailing scheduleTJI® 560 rim joist: Toenail with 10d (0.128" x 3")nails, one each side ofTJI® joist flangeRim to TJI® JoistSquash Blocks to TJI® Joist(Load bearing wall above)One 10d (0.128" x 3")nail into each flange118" TJ® Rim Board or114" or 1 12" TimberStrand® LSL.Also see detail B2Locate rim board joint between joists.134" minimum bearingOne 8d (0.113" x 212")nail each side. Drivenails at an angle atleast 112" from end.312" minimumintermediate bearing514" may be requiredfor maximumcapacityThese placement plans have been developed for the specificaƟon of productsbased on project informaƟon provided. This service is solely intended forproduct applicaƟon assurance; and, is not intended to circumvent the need fora design professional as determined by the building code. The designer ofrecord and/or builder/framer is responsible to assure these drawings arecompaƟble with the overall project.CANTILEVERS/TRUSSESDesign assumes all trusses at floor canƟlevers are connectedto the wall and NOT to the Trus Joist rimboard. If trusses needto connect to the Trus Joist rimboard, contact Weyerhaeuserfor a connecƟon detail prior to installaƟon.JOIST & BEAM HANGER FACE NAILING REQUIREMENTS* FOR3 & 4 PLY SUPPORTING MEMBERSFor IUS or THF Hangers - Use 10D (0.148") x 3" nails.For MIU, HU, HHUS, HGUS or HD, THD, THDH Hangers - Use16d (0.162") x 3 1/2" nails.*For hangers that have joist fasteners/connecƟons, fill allholes with the manufacturer's recommended fasteners. Start Framing Here.ProductsPlotID Length Product Plies Net QtyFBk1 34' 0 13/16" 11 7/8" TJI 210 joist 1 1TS4 31' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS5 30' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 17TS7 21' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS9 17' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 5TS12 11' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS13 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2TS14 9' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS15 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 3TS16 7' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1STCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 10AccessoriesPlotID Length Product Plies Net Qty23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF 1 41Optional Stone Fireplace at Egress - ADDPlotID Length Product Plies Net QtyFBk1 4' 0 5/8" 11 7/8" TJI 210 joist 1 1TS8-2 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 4TS13 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2TS17-2 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2Optional Stone Fireplace at Egress - ADDPlotID Qty Manuf Product Backer Blks Web StiffH2 2 Simpson IUS3.56/11.88 No NoOptional Stone Fireplace at Egress - REMOVEPlotID Length Product Plies Net QtyTS5 30' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2Optional Stone Fireplace - ADDPlotID Length Product Plies Net QtyFBk1 4' 0 5/8" 11 7/8" TJI 210 joist 1 1TS8-2 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 4TS13 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2Optional Stone Fireplace - REMOVEPlotID Length Product Plies Net QtyTS5 30' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2Egress @ Full Foundation - ADDPlotID Length Product Plies Net QtyTS17-2 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2Egress @ Full Foundation - ADDPlotID Qty Manuf Product Backer Blks Web StiffH3 2 Simpson IUS1.81/9.5 No NoAdditional TimberStrand for Ledger @ FULL Basement-1PlotID Length Product Plies Net Qty- 40' 0" 1-1/2" x 11-7/8"1.5E TimberStrand LSL 1 1CSCSCSB1B2B2A3A3A3A3A3A3A3CSA3A3B1B4B2TS17-2BBO2TS4TS14TS12TS13TS15TS16TS13STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1SB6SB2TS15TS7FBk11' 7 3/16"FBk1FBk1FBk11' 7 3/16"TS17-2STCa1STCa1STCa11' 7 3/16"FBk1SB9FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1TS15TS519.2" O.C.TS519.2" O.C.TS519.2" O.C.TS919.2" O.C.TS1319.2" O.C.TS519.2" O.C.TS8-219.2" O.C.H3H2Blocking per site requirements.Refer to Hanson's Detail 2/S2.An additional 8 PSF DL has been added to account fortile load on this floor and tile walls for optionalbathrooms. See architecturals for tile locations.An additional 20 PSF DL has been added to accountfor load from kitchen island counter top.An additional 40 PSF DL has been added to account forfireplace hearth at optional fireplace locations.An additional 135 PLF DL has been added to accountfor stone wall at stone fireplace options.No Material Change for Bath Options.STONE FIREPLACE @ EGRESS OPTIONSTONE FIREPLACE OPTIONALL BATH OPTIONS HAVEBEEN ACCOUNTED FOR. NOMATERIAL CHANGE NEEDED.EGRESS WINDOW @ FULL FOUNDATIONSEE DETAIL FOR DECK LEDGER ATTACHMENT@ FULL FOUNDATION WITH 2 INCH FOAM. Start Framing Here.Optional Morning Room - ADDPlotID Length Product Plies Net QtyFBk1 10' 7 7/16" 11 7/8" TJI 210 joist 1 1TS2 41' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS3 40' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 3TS6 27' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 5TS12 11' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1STCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 2Optional Morning Room - REMOVEPlotID Length Product Plies Net QtyTS4 31' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS5 30' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 3TS9 17' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 5CSCSB1A3A3B4TS21' 7 3/16"BBO26STCa1STCa1STCa1STCa1TS12FBk11' 7 3/16"1' 7 3/16"FBk1FBk1FBk1TS319.2" O.C.TS619.2" O.C.MORNING ROOM OPTIONSheet:2OF4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationWEEKES FOREST PRODUCTS, INC. * 2600 COMO AVENUE651-644-9807 * ST. PAUL, MN 55108LIVE LOAD:TOTAL LOAD:40DEFLECTION:L/480 LIVEL/240 TOTALDRAWN BY:JLT52WIND/EXP.:N/ADATE:02.16.21Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.User Defined Point LoadUser Defined Line LoadUser Defined Area LoadBeam By OthersPost By OthersConstruction Detail Callout(See Framer's Pocket Guide)Excessive Point Load(WARNING: Member design did notinclude this load. Special considerationis required by the designer of record.)Required Bearing Length(Only placed at insufficient bearinglocations.)BBOPBOPL: 12KSymbol LegendLayout Start LocationSCALE: 1/4" = 1'-0"Only header openings and roof loads which affect Weyerhaeuserproduct sizes have been denoted on this layout. In addiƟon to any 'CS'detail callouts shown, solid blocking and/or squash blocks are requiredto provide verƟcal load transfer from all concentrated load locaƟons tofoundaƟon below. See Pocket Framer's Guide for appropriate detail(s).Joists may be shiŌed up to 3" if floor panel edgeis supported and span raƟng is not exceeded.DO NOT CUT FLANGES.This layout is intended for the use of Trus Joist® engineered woodproducts only. The subsƟtuƟon of other engineered wood products withthis layout isNOT PERMITTED. Please idenƟfy the TJI®, TimberStrand®LSL, Microllam® LVL, and Parallam® PSL stamps on the product to ensurethat this layout is valid for the products actually installed.Blocking at Kitchen IslandINSTALL (4) 2X6 SQUASH BLOCKS UNDER ALL POINT LOADS. FORPOINT LOADS OVER 10,000# CONTACT LENNAR FOR DETAILS Start Framing Here.Framing Connector SummaryPlotID Qty Manuf Product Backer Blks Web StiffH1 2 Simpson HUS1.81/10 No NoH2 1 Simpson HUCQ1.81/9-SDS No NoH4 15 Simpson IUS2.37/11.88 No NoProductsPlotID Length Product Plies Net QtyR32' 32' 0" 11 7/8" TJI 360 joist 1 6R30' 30' 0" 11 7/8" TJI 360 joist 1 5R21' 21' 0" 11 7/8" TJI 360 joist 1 7R17' 17' 0" 11 7/8" TJI 360 joist 1 6R16' 16' 0" 11 7/8" TJI 360 joist 1 1R13' 13' 0" 11 7/8" TJI 360 joist 1 1R10' 10' 0" 11 7/8" TJI 360 joist 1 7RBk1 11 7/8" 11 7/8" TJI 360 joist 1 1TS2-2 13' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2TS3-2 9' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2TS4 2' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS5 10' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 1 1STCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 10Wall FramingPlotID Length Product Plies Net QtyTSHd2-3 4' 0" 1 1/2" x 9 1/2" 1.5E TimberStrand LSL 3 3AccessoriesPlotID Length Product Plies Net Qty23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 38LEVEL NOTESCurrent Date:2/16/2021File Name:SPRINGFIELD V.jvlLevel Name:2nd FloorBuilding Code - Design Methodology:IBC 2012Members with Design Overridden:TJ-Pro Rating (Weighted Average):40Minimum Level TJ - Pro Rating & Joist:TJ-Pro rating = 31, joist = R21'(i45750)Maximum Level TJ - Pro Rating & Joist:TJ-Pro rating = 61, joist = R10'(i45773)FLOORFloor Container:FC2, FC4, FC9Use/Occupancy:ResidentialLivingAreasFloor Area Loading is:40.0 lb/ft² Live Load & 10.0 lb/ft² Dead LoadOperator Added Additional LoadsMaximum Allowed Deflection:L/480 Live Load & L/240 Total LoadTJ-Pro Rating Information:Weighted Average:FC2: 41; FC4: 40; FC9: 39Directly Applied Ceiling:NoneDecking Attachment:Glue and NailDecking Material:23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FFPerpendicular Partition:NoStrapping at max 8' o.c.:NoneBlocking at max 8' o.c.:NoPoured Flooring:NoFamily Room Window Option - ADDPlotID Length Product Plies Net QtyTSHd1-3 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 3 3CSE1A3A3A3B4BBO8TS2-2TS3-2STCa1STCa1STCa1STCa1STCa1STCa1BBOBk1TS4H1TS5R16'9 3/16"1' 8 1/8"STCa1R13'RBk1BBO1-2BBO7TSHd2-31' 10 7/8"1' 4 13/16"H4H1H23"TSHd1-3R32'19.2" O.C.R17'19.2" O.C.R21'19.2" O.C.R30'19.2" O.C.R10'19.2" O.C.H4H4An additional 8 PSF DL has been added to account fortile load on this floor and tile walls for optionalbathrooms. See architecturals for tile locations.No Material Change for Bath Options.ALL BATH OPTIONS HAVEBEEN ACCOUNTED FOR. NOMATERIAL CHANGE NEEDED.FAMILY ROOM WINDOW OPTIONMorning Room Option - ADDPlotID Qty Manuf Product Backer Blks Web StiffH4 10 Simpson IUS2.37/11.88 No NoMorning Room Option - ADDPlotID Length Product Plies Net QtyM1-3 17' 0" 1 3/4" x 18" 2.0E Microllam LVL 3 3Morning Room Option - REMOVEPlotID Length Product Plies Net QtySTCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 1A31' 10 7/8"M1-3STCa1R32'19.2" O.C.R17'19.2" O.C.H4MORNING ROOM OPTIONElevation E - ADDPlotID Length Product Plies Net QtyTS1-2 21' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2TS1-2ELEVATION E3rd Car Garage - 12'-0" @ Elevation E - ADDPlotID Length Product Plies Net QtyTSHd3-3 10' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 3 3TSHd3-33RD CAR GARAGE - 12'-0" @ ELEVATION ESheet:3OF4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationWEEKES FOREST PRODUCTS, INC. * 2600 COMO AVENUE651-644-9807 * ST. PAUL, MN 55108LIVE LOAD:TOTAL LOAD:40DEFLECTION:L/480 LIVEL/240 TOTALDRAWN BY:JLT52WIND/EXP.:N/ADATE:02.16.21Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.User Defined Point LoadUser Defined Line LoadUser Defined Area LoadBeam By OthersPost By OthersConstruction Detail Callout(See Framer's Pocket Guide)Excessive Point Load(WARNING: Member design did notinclude this load. Special considerationis required by the designer of record.)Required Bearing Length(Only placed at insufficient bearinglocations.)BBOPBOPL: 12KSymbol LegendLayout Start LocationSCALE: 1/4" = 1'-0"Only header openings and roof loads which affect Weyerhaeuserproduct sizes have been denoted on this layout. In addiƟon to any 'CS'detail callouts shown, solid blocking and/or squash blocks are requiredto provide verƟcal load transfer from all concentrated load locaƟons tofoundaƟon below. See Pocket Framer's Guide for appropriate detail(s).Joists may be shiŌed up to 3" if floor panel edgeis supported and span raƟng is not exceeded.DO NOT CUT FLANGES.This layout is intended for the use of Trus Joist® engineered woodproducts only. The subsƟtuƟon of other engineered wood products withthis layout isNOT PERMITTED. Please idenƟfy the TJI®, TimberStrand®LSL, Microllam® LVL, and Parallam® PSL stamps on the product to ensurethat this layout is valid for the products actually installed. Elevation E - ADDPlotID Length Product Plies Net QtyTSHd1-3 7' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 3 3TSHd1-3BBOHd1-2ELEVATION ESheet:4OF4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationWEEKES FOREST PRODUCTS, INC. * 2600 COMO AVENUE651-644-9807 * ST. PAUL, MN 55108LIVE LOAD:TOTAL LOAD:35DEFLECTION:L/480 LIVEL/240 TOTALDRAWN BY:JLT55WIND/EXP.:N/ADATE:02.16.21Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.User Defined Point LoadUser Defined Line LoadUser Defined Area LoadBeam By OthersPost By OthersConstruction Detail Callout(See Framer's Pocket Guide)Excessive Point Load(WARNING: Member design did notinclude this load. Special considerationis required by the designer of record.)Required Bearing Length(Only placed at insufficient bearinglocations.)BBOPBOPL: 12KSymbol LegendLayout Start LocationSCALE: 1/4" = 1'-0"This layout is intended for the use of Trus Joist® engineered woodproducts only. The subsƟtuƟon of other engineered wood products withthis layout isNOT PERMITTED. Please idenƟfy the TJI®, TimberStrand®LSL, Microllam® LVL, and Parallam® PSL stamps on the product to ensurethat this layout is valid for the products actually installed. FOUNDATION DETAILAT FOOTING STEP LOCATIONS1S1DescriptionDateRevisionProject Number:Date:S11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20222.0011-1-222022 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2S1WALL SECTIONLOOKOUT WALL CONDITION3S1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4S1WALL SECTIONFULL HEIGHT WALL CONDITION5S1REBAR TABLE6S1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2022©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS: F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE: SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE 1,500 PSF MINIMUMGENERAL NOTES1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3. 112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOILPRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THERESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGNFOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW ANDCONSENT OF THE HANSON GROUP.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2022.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE S8 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON S11FLOOR TO SILLCONNECTION SEE S10WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4 x 5'-0" HOOKS @ 24" O.C.EMBEDDED IN FOUNDATIONWALL & CAST INTO SLAB(MAY REDUCE 2'-0" LEG LENGTH& DRILL IN & EPOXY 8" MIN.INTO FOUNDATION WALL)3'-0"NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)2'-0".GPPCT%QTRQTCVKQPVJ#XG05WKVG2N[OQWVJ/0 COPYRIGHT HANSON GROUP LLC 2022©DescriptionDateRevisionJanuary 1, 2022Project Number:Date:2.001S22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2246665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1S2BRICK LEDGE INFO5S2WALL SECTIONAT WINDOW WELL LOCATIONS6S2STOOP INFO7S2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2S2BLOCKING DETAILFLOOR JOIST CONDITION3S2BLOCKING DETAILFLOOR TRUSS CONDITION4S2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/S1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/S1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/S1 OR 3/S1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/S1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/S2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/S1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)FLOOR MEMBERSPACING8'-0"9'-0"10'-0"16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/ASLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.* FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERNAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/S1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/S1LOOKOUTWALLSEE S5GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.BACKFILL HEIGHT (NOT TO EXCEED 10'-0")SEE 5/S1 FOR TYPICALFOUNDATION WALL &FOOTING CONSTRUCTIONMAINTAIN MIN. 6" WIDESTEMWALL WITHEXTERIOR LEDGEWOOD FLOORSYSTEM BY OTHERSBACKFILL BELOW EXTERIORSTOOP SLABS WITH COMPACTEDGRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM)FLASHING &WATERPROOFINGBY OTHERSSTOOP SLAB BY OTHERS* SEE 1/S2 FOR FLOORTO SILL CONNECTION112" CLEARBUILD UP w/ RIGIDINSULATION BELOW SLABTO MAINTAIN 10'-0" MAX.BACKFILL HEIGHT ASREQ'D OR PROVIDE SITESPECIFIC ENGINEERING(MAY SUBTRACT 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY & CLAY SOILS DUE TO GRANULAR FILL BELOW STOOP SLAB) * MODIFIED CLEAR HEIGHT* SEE REBAR TABLE 6/S1FOR VERTICAL REBAR* SEE 2/S2 FOR ANCHOR BOLTS* FOR REBAR TABLE 6/S1, FLOOR TO SILL CONNECTION TABLE 1/S2, AND ANCHOR BOLT TABLE 2/S2USE MODIFIED CLEAR HEIGHT OF 9'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 8'-6" ANDUSE MODIFIED CLEAR HEIGHT OF 10'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 9'-6"(MAY REDUCE BACKFILL HEIGHT BY 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY AND CLAY SOILS).GPPCT%QTRQTCVKQPVJ#XG05WKVG2N[OQWVJ/0 UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. BWPsAbove3rd Car Garage - 12'-0" @ Elevation E - ADDPlotID Length Product Plies Net QtyTSHd3-3 10' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 3 33RD CAR GARAGE - 12'-0" @ ELEVATION E Elevation E - ADDPlotID Length Product Plies Net QtyTSHd1-3 7' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 3 3ELEVATION E 40,000 X X 40,000 2160 40,000 3000 3000 2160 3000 .72 .72 .28 40,000 40,000 13.33 13.33 .28 3.7 2.2 66,000 280 415 415 4001 600 600 -185 180 90 20467 Gargoyle Lane Date Certificate Posted X Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here X R-15 X X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:66,000 Capacity in Gallons:Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code X Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " round duct OR " metal duct Duct system air tightness: Heating or Cooling Ducts Outside Conditioned Spaces Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Windows & Doors Average U-Factor (excludes skylights and one door ) U: 0.31 Solar Heat Gain Coefficient (SHGC):0.29 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Nat Gas Nat Gas Elect GPVL-50 13ACXN-036 Fuel Type Manufacturer Lennox AOSmith Lennox Model ML193UH070XE36B 13 Location of duct or system: Rating or Size 50 Output in Tons:3 Efficiency SEER /EER Residential Load Calculation Heating Loss Heating Gain Cooling Load 54,342 23,089 28,865 MECHANICAL VENTILATION SYSTEM Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Select Type Heat Recover Ventilator (HRV) Capacity in cfms:180 MN License Number Lennar 1413 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply Insulation Location Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateNew Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.10/20/2022 Mailing Address of the Dwelling or Dwelling Unit City Lakeville20467 Gargoyle Lane Name of Residential Contractor Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Interior R5 + R10 Exterior Interior Interior Balanced Ventilation capacity in cfms:Mech Room Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms: 90 High: Energy Recover Ventilator (ERV) Capacity in cfms:High: Location of duct or system: 000000Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.”(NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 20467 Gargoyle Lane US Home LLC dba Lennar Jesse Schwarzrock 612-346-2648 Jesse.Schwarzrock@Lennar.com Residential Development 57174 Chad Johnson Stantec 651-325-6860 chad.johnson@stantec.com University of Minnesota 5/31/23 10/20/2022Kurt NiskaDigitally signed by Kurt Niska Date: 2022.10.20 10:30:54 -05'00' 11/8/22 X PM