Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA209307-APPROVED - Moore Engineering Letter Flat
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2 'RPXVVWUXFWXUDO#JPDLOFRP dŽ͗ ůƵĞZĂǀĞŶ^ŽůĂƌ ϭϰϬϯEŽƌƚŚZĞƐĞĂƌĐŚtĂLJ͕ƵŝůĚŝŶŐ: KƌĞŵ͕hd͘ϴϰϬϵϳ ^ƵďũĞĐƚ͗ ĞƌƚŝĨŝĐĂƚŝŽŶ>ĞƚƚĞƌ DŽŽƌĞZĞƐŝĚĞŶĐĞ ϭϴϮϮϮ,ŝĚĞĂǁĂLJdƌů >ĂŬĞǀŝůůĞ͕DE͘ϱϱϬϰϰ dŽtŚŽŵ/ƚDĂLJŽŶĐĞƌŶ͕ ĞƐŝŐŶƌŝƚĞƌŝĂ͗ භ ƉƉůŝĐĂďůĞŽĚĞƐсϮϬϭϴ/ͬ/Z͕^ϳͲϭϲ භ ZŽŽĨĞĂĚ>ŽĂĚсϳƉƐĨ;DWϭΘϮͿ භ ZŽŽĨ>ŝǀĞ>ŽĂĚсϮϬƉƐĨ භ tŝŶĚ^ƉĞĞĚсϭϭϱŵƉŚ;sƵůƚͿ͕džƉŽƐƵƌĞ භ භ ^ŝŶĐĞƌĞůLJ͕ :ŽŚŶĂůǀĞƌƚ͕W͘͘ WƌŽũĞĐƚŶŐŝŶĞĞƌ :ĂŶƵĂƌLJϭϮ͕ϮϬϮϯ dŚĞƌŽŽĨƐƚƌƵĐƚƵƌĞƐŽĨ;DWϭΘϮͿĐŽŶƐŝƐƚŽĨĐŽŵƉŽƐŝƚŝŽŶƐŚŝŶŐůĞŽŶƌŽŽĨƉůLJǁŽŽĚƚŚĂƚŝƐƐƵƉƉŽƌƚĞĚďLJƉƌĞͲŵĂŶƵĨĂĐƚƵƌĞĚƚƌƵƐƐĞƐ ƚŚĂƚĂƌĞƐƉĂĐĞĚĂƚΛϮϰΗŽ͘Đ͘͘dŚĞƚŽƉĐŚŽƌĚƐ͕ƐůŽƉĞĚĂƚϮϳĚĞŐƌĞĞƐ͕ĂƌĞϮdžϰƐĞĐƚŝŽŶƐ͕ƚŚĞďŽƚƚŽŵĐŚŽƌĚƐĂƌĞϮdžϰƐĞĐƚŝŽŶƐĂŶĚƚŚĞ ǁĞďŵĞŵďĞƌƐĂƌĞϮdžϰƐĞĐƚŝŽŶƐ͘dŚĞƚƌƵƐƐŵĞŵďĞƌƐĂƌĞĐŽŶŶĞĐƚĞĚďLJƐƚĞĞůŐƵƐƐĞƚƉůĂƚĞƐ͘dŚĞŵĂdžƵŶƐƵƉƉŽƌƚĞĚƉƌŽũĞĐƚĞĚ ŚŽƌŝnjŽŶƚĂůƚŽƉĐŚŽƌĚƐƉĂŶŝƐĂƉƉƌŽdžŝŵĂƚĞůLJϲΖͲϬΖΖ͘ dŚĞĞdžŝƐƚŝŶŐƌŽŽĨĨƌĂŵŝŶŐƐLJƐƚĞŵƐŽĨ;DWϭΘϮͿĂƌĞũƵĚŐĞĚƚŽďĞĂĚĞƋƵĂƚĞƚŽǁŝƚŚƐƚĂŶĚƚŚĞůŽĂĚŝŶŐŝŵƉŽƐĞĚďLJƚŚĞŝŶƐƚĂůůĂƚŝŽŶŽĨ ƚŚĞƐŽůĂƌƉĂŶĞůƐ͘EŽƌĞŝŶĨŽƌĐĞŵĞŶƚŝƐŶĞĐĞƐƐĂƌLJ͘ 'ƌŽƵŶĚ^ŶŽǁ>ŽĂĚсϱϬƉƐĨͲZŽŽĨ^ŶŽǁ>ŽĂĚсϯϱƉƐĨ dŚĞƐƉĂĐŝŶŐŽĨƚŚĞƐŽůĂƌƐƚĂŶĚŽĨĨƐƐŚŽƵůĚďĞŬĞƉƚĂƚϰϴΗŽ͘Đ͘ĨŽƌůĂŶĚƐĐĂƉĞĂŶĚϮϰΗŽ͘Đ͘ĨŽƌƉŽƌƚƌĂŝƚŽƌŝĞŶƚĂƚŝŽŶ͕ǁŝƚŚĂƐƚĂŐŐĞƌĞĚ ƉĂƚƚĞƌŶƚŽĞŶƐƵƌĞƉƌŽƉĞƌĚŝƐƚƌŝďƵƚŝŽŶŽĨůŽĂĚƐ͘ ũŽďƐŝƚĞŽďƐĞƌǀĂƚŝŽŶŽĨƚŚĞĐŽŶĚŝƚŝŽŶŽĨƚŚĞĞdžŝƐƚŝŶŐĨƌĂŵŝŶŐƐLJƐƚĞŵǁĂƐƉĞƌĨŽƌŵĞĚďLJĂŶĂƵĚŝƚƚĞĂŵŽĨůƵĞZĂǀĞŶ^ŽůĂƌĂƐĂ ƌĞƋƵĞƐƚĨƌŽŵŽŵƵƐ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌŝŶŐ͘ůůƌĞǀŝĞǁŝƐďĂƐĞĚŽŶƚŚĞƐĞŽďƐĞƌǀĂƚŝŽŶƐĂŶĚƚŚĞĚĞƐŝŐŶĐƌŝƚĞƌŝĂůŝƐƚĞĚďĞůŽǁĂŶĚ ŽŶůLJĚĞĞŵĞĚǀĂůŝĚŝĨƉƌŽǀŝĚĞĚŝŶĨŽƌŵĂƚŝŽŶŝƐƚƌƵĞĂŶĚĂĐĐƵƌĂƚĞ͘ KŶƚŚĞĂďŽǀĞƌĞĨĞƌĞŶĐĞĚƉƌŽũĞĐƚ͕ƚŚĞƌŽŽĨƐƚƌƵĐƚƵƌĂůĨƌĂŵŝŶŐŚĂƐďĞĞŶƌĞǀŝĞǁĞĚĨŽƌĂĚĚŝƚŝŽŶĂůůŽĂĚŝŶŐĚƵĞƚŽƚŚĞŝŶƐƚĂůůĂƚŝŽŶŽĨ ƚŚĞƐŽůĂƌWsĂĚĚŝƚŝŽŶƚŽƚŚĞƌŽŽĨ͘dŚĞƐƚƌƵĐƚƵƌĂůƌĞǀŝĞǁŽŶůLJĂƉƉůŝĞƐƚŽƚŚĞƐĞĐƚŝŽŶŽĨƚŚĞƌŽŽĨƚŚĂƚŝƐĚŝƌĞĐƚůLJƐƵƉƉŽƌƚŝŶŐƚŚĞƐŽůĂƌ WsƐLJƐƚĞŵĂŶĚŝƚƐƐƵƉƉŽƌƚŝŶŐĞůĞŵĞŶƚƐ͘dŚĞŽďƐĞƌǀĞĚƌŽŽĨĨƌĂŵŝŶŐŝƐĚĞƐĐƌŝďĞĚďĞůŽǁ͘/ĨĨŝĞůĚĐŽŶĚŝƚŝŽŶƐĚŝĨĨĞƌ͕ĐŽŶƚƌĂĐƚŽƌƚŽ ŶŽƚŝĨLJĞŶŐŝŶĞĞƌƉƌŝŽƌƚŽƐƚĂƌƚŝŶŐĐŽŶƐƚƌƵĐƚŝŽŶ͘ dŚĞƐĐŽƉĞŽĨƚŚŝƐƌĞƉŽƌƚŝƐƐƚƌŝĐƚůLJůŝŵŝƚĞĚƚŽĂŶĞǀĂůƵĂƚŝŽŶŽĨƚŚĞĨĂƐƚĞŶĞƌĂƚƚĂĐŚŵĞŶƚ͕ƵŶĚĞƌůLJŝŶŐĨƌĂŵŝŶŐĂŶĚƐƵƉƉŽƌƚŝŶŐ ƐƚƌƵĐƚƵƌĞŽŶůLJ͘dŚĞĂƚƚĂĐŚŵĞŶƚΖƐƚŽƚŚĞĞdžŝƐƚŝŶŐƐƚƌƵĐƚƵƌĞĂƌĞƌĞƋƵŝƌĞĚƚŽďĞŝŶĂƐƚĂŐŐĞƌĞĚƉĂƚƚĞƌŶƚŽĞŶƐƵƌĞƉƌŽƉĞƌĚŝƐƚƌŝďƵƚŝŽŶ ŽĨůŽĂĚŝŶŐ͘ůůƉĂŶĞůƐ͕ƌĂĐŬŝŶŐĂŶĚŚĂƌĚǁĂƌĞƐŚĂůůďĞŝŶƐƚĂůůĞĚƉĞƌŵĂŶƵĨĂĐƚƵƌĞƌƐƉĞĐŝĨŝĐĂƚŝŽŶƐĂŶĚǁŝƚŚŝŶƐƉĞĐŝĨŝĞĚĚĞƐŝŐŶ ůŝŵŝƚĂƚŝŽŶƐ͘ůůǁĂƚĞƌƉƌŽŽĨŝŶŐƐŚĂůůďĞƉƌŽǀŝĚĞĚďLJƚŚĞŵĂŶƵĨĂĐƚƵƌĞƌ͘ŽŵƵƐ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌŝŶŐĂƐƐƵŵĞƐŶŽƌĞƐƉŽŶƐŝďŝůŝƚLJĨŽƌ ŵŝƐƵƐĞŽƌŝŵƉƌŽƉĞƌŝŶƐƚĂůůĂƚŝŽŶŽĨƚŚĞƐŽůĂƌWsƉĂŶĞůƐŽƌƌĂĐŬŝŶŐ͘ WůĞĂƐĞĐŽŶƚĂĐƚŵĞǁŝƚŚĂŶLJĨƵƌƚŚĞƌƋƵĞƐƚŝŽŶƐŽƌĐŽŶĐĞƌŶƐƌĞŐĂƌĚŝŶŐƚŚŝƐƉƌŽũĞĐƚ͘ EŽƚĞ͗^ĞŝƐŵŝĐĐŚĞĐŬŝƐŶŽƚƌĞƋƵŝƌĞĚƐŝŶĐĞ^Ɛф͘ϰŐĂŶĚ^ĞŝƐŵŝĐĞƐŝŐŶĂƚĞŐŽƌLJ;^Ϳф ƚƚĂĐŚŵĞŶƚ͗ϭͲϱͬϭϲĚŝĂ͘ůĂŐƐĐƌĞǁǁŝƚŚϮ͘ϱŝŶĐŚŵŝŶ͘ĞŵďĞĚŵĞŶƚ ĚĞƉƚŚ͕ĂƚƐƉĂĐŝŶŐƐŚŽǁŶĂďŽǀĞ͘ 0RRUH/DNHYLOOH01 I hereby certify that this plan, specification or report was prepared by me or under mydirect supervision and that I am a duly Licensed Professional Engineer under the laws ofthe State of Minnesota.John A. Calvert, License No. 52823 Expiration Date: 30-June-2024 Digitally signed by John A. Calvert Date: 2023.01.12 13:02:59 -07'00' Please provide a copy of the City Approved plans on site at final inspection. Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 01/13/2023dpfannenstein ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2 'RPXVVWUXFWXUDO#JPDLOFRP 50 psf (ASCE7 - Eq 7-1) 1 (ASCE7 - Table 7-2) 1 (ASCE7 - Table 7-3) 1 35.0 psf (ASCE7 - Eq 7-2) 1 35.0 psf 3.37 psf 3.0 psf 2.00 ft 6.08 ft 12.17 sft 37 lb 4.00 2.00 0.73 0.00 (Ceiling Not Vaulted) 0.27 7.0 psf 7.9 psf *UDYLW\/RDGLQJ PV System Weight Weight of PV System (Per Blue Raven Solar) X Standoff Spacing = Y Standoff Spacing = Note: PV standoffs are staggered to ensure proper distribution of loading 2x4 Top Chords @ 24"o.c. I = Importance Factor = Cs = Slope Factor = Standoff Tributary Area = ps = Cspf ps = Sloped Roof Snow Load = pf = Flat Roof Snow Load = DL Adjusted to 27 Degree Slope Roof Snow Load Calculations pg = Ground Snow Load = Ce = Exposure Factor = pf = 0.7 CeCtI pg Ct = Thermal Factor = Roof Live Load = 20 psf Roof Plywood Roof Dead Load (MP1&2) Composition Shingle Note: Roof live load is removed in area's covered by PV array. DL Adjusted to 27 Degree Slope Point Loads of Standoffs Miscellaneous Vaulted Ceiling Total Roof DL (MP1&2) PV Dead Load = 3 psf (Per Blue Raven Solar) 0RRUH/DNHYLOOH01 BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2 'RPXVVWUXFWXUDO#JPDLOFRP 115 mph C Gable Roof 27 degrees 20 ft 21.3 ft 0 ft (Eq. 26.10-1) 0.90 (Table 30.3-1) 1.00 (Fig. 26.8-1) 0.85 (Table 26.6-1) 1.00 115 mph (Fig. 26.5-1A) II (Table 1.5-1) qh = 25.95 Zone 1 Zone 2 Zone 3 Positive ya =0.77 0.80 0.80 0.77 GCp = (Fig. 30.3) Uplift Pressure =SVI SVI SVI SVI (T ASD Uplift Pressure =SVI SVI SVI SVI X Standoff Spacing = 2.00 2.00 1.33 Y Standoff Spacing = 6.08 3.04166667 3.04166667 Tributary Area = 12.17 6.08 4.06 Dead Load on attachment = 37 lb 18 lb 12 lb Footing Uplift (0.6D+0.6W) = -197 lb -179 lb -174 lb Zone 1 Zone 2 Zone 3 Positive ya =0.75 0.80 0.80 0.75 GCp = (Fig. 30.3) Uplift Pressure =SVI SVI SVI SVI (T ASD Uplift Pressure (0.6W)=SVI SVI SVI SVI X Standoff Spacing = 4.00 4.00 2.67 Y Standoff Spacing = 3.50 1.75 1.75 Tributary Area = 14.00 7.00 4.67 Dead Load on attachment = 42.00 21.00 14.00 Footing Uplift (0.6D+0.6W) = -220 lb -205 lb -195 lb -220 lb 450 lb Therefore, OK Fastener =1 - 5/16" dia. lag Number of Fasteners = 1 Embedment Depth = 2.5 Pullout Capacity Per Inch = 250 lb Fastener Capacity = 625 lb w/ F.S. of 1.5 & DOL of 1.6= 667 lb Therefore, OK Fastener Capacity Check Mean Roof Height Ground Elevation Kd (Wind Directionality Factor) = 667.2 lb capacity > 220 lb demand Ke (Ground Elevation Factor) = V (Design Wind Speed) = Risk Category = Standoff Uplift Calculations-Portrait Standoff Uplift Calculations-Landscape Standoff Uplift Check Standoff Uplift Capacity = 450 lb capacity > 220 lb demand :LQG&DOFXODWLRQV Maximum Design Uplift = Design Wind Pressure Calculations qh = 0.00256 * Kz * Kzt * Kd * Ke * V^2 Kz (Exposure Coefficient) = Kzt (topographic factor) = Wind Speed Exposure Category Roof Shape Roof Slope Effective Wind Area WĞƌ^ϳͲϭϲŽŵƉŽŶĞŶƚƐĂŶĚůĂĚĚŝŶŐ Input Variables 0RRUH/DNHYLOOH01 BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'RPXV6WUXFWXUDO(QJLQHHULQJ//& 32%R[ %URRPILHOG&2 'RPXVVWUXFWXUDO#JPDLOFRP 03 PASS Dead Load 7.9 psf PV Load 3.4 psf Snow Load 35.0 psf Governing Load Combo = DL + SL Total Load 46.2 psf Fb (psi) = f'b x Cd x Cf x Cr (NDS Table 4.3.1) 900 x 1.15 x 1.5 x 1.15 Allowed Bending Stress = 1785.3 psi (wL^2) / 8 = 416.0094 ft# = 4992.112 in# Actual Bending Stress = (Maximum Moment) / S = 1630.1 psi L/180 (E = 1600000 psi Per NDS) = 0.4 in Deflection Criteria Based on = (w*L^4) / (185*E*I) = = L/550 > L/180 Therefore OK Allowed Deflection (Live Load) =L/240 0.3 in (w*L^4) / (185*E*I) L/728 > L/240 Therefore OK Member Area = Fv (psi) = 180 psi (NDS Table 4A) Allowed Shear = Fv * A =Max Shear (V) = w * L / 2 =277 lb )UDPLQJ&KHFN 5.3 in^2 Check Shear w = 92 plf 2x4 Top Chords @ 24"o.c. Member Span = 6' - 0" 945 lb Allowed > Actual -- 29.4% Stressed -- Therefore, OK DF#2 Member Spacing @ 24"o.c. Maximum Moment = Check Deflection I (in^4) 5.36 Lumber Sp/Gr Actual Deflection (Live Load)= Allowed Deflection (Total Load) = Actual Deflection (Total Load) = Allowed > Actual -- 91.4% Stressed -- Therefore, OK Member Properties Member Size 2x4 S (in^3) 3.06 0.099 in Continuous Span 0.131 in Check Bending Stress (True Dimensions) 0RRUH/DNHYLOOH01