HomeMy WebLinkAboutLA209065 - 18253 Glacier Way Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. HOUSE FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARGE PLATE HEIGHT 10' - 7 1/8"ALUMINUM SOFFIT & FASCIA TYP.6" SMARTSIDETRIM TYP.VINYL BOARD & BATTEN TYP.VINYLLAP SIDING TYP.SEE COLUMNDETAIL, SHEET A-501CULTURED STONEW/ CONCRETE CAP 3' - 6"ADDRESS STONE3 PHOTO CELL LIGHTS @ FRONTGARAGE PLATE10' -1 1/8"6" SMARTSIDE FREIZE BOARD TYP. T.O. GARAGE FOUNDATION-0' -6"0' - 6"7" / 12"6" / 12"8" 12"8" 12"0' - 8 1/4"24" RETURNS7" 12"8" / 12"7" / 12"7" / 12"8" / 12"ALUMINUM SOFFIT& FASCIAVINYL SIDING& CORNERS7" / 12"7" 12"7" 12"7" 12"7" / 12"8" / 12"8" / 12"6" 12"7" / 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNERMUSTVERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:TOTAL:LOWER:REV.6REV. 7REV. 8REV. 9REV. 10REV. 11PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337952-953-4000ONETENTENHOMES.COMRELEASED11/30/2022 2:26:21 PMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-201OTT33211.23.22 CB12111195887329311.17.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR10.12.22 CBTHE PAYTON PLATINUM-TRADITIONAL1/8" = 1'-0"A-2012LEFT ELEVATION1/8" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014RIGHT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-404 MAIN FLOORA-405 UPPER FLOORA-501 ROOF PLAN/ DETAILS/ SCHEDULEConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/28/2022dmathews
27' - 6"22' - 6"25' - 4"1' - 10"19' - 10"17' - 4"31' - 2"48' - 6"30' - 2"19' - 10"16' - 8"11' - 10"0' - 4"1' - 4 1/2"8' - 3" M.O.1' - 4 1/2"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"2' - 0"20' - 6"14' - 0"5' - 10"28' - 2"2' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.50' - 0"50' - 0":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE14' - 0"29' - 6"5' - 0"43' - 6"48' - 6"4' - 0 5/8"6' - 9 3/8"15' - 6"15' - 7 3/4"3' - 10 3/4"3' - 10 3/4"20' - 0 3/4"28' - 4"11' - 0"20' - 2"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.* ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATION* ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATION15' - 6"1' - 0"11' - 8"0' - 2"LEAVE A 12" GAP IN FOOTING FOR PLUMBING 8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 14" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN FOOTING FOR PLUMBING 10' - 2 3/4"3' - 6"0' - 3 1/4"9' - 3 1/4"20' - 2 3/4"2' - 0"3' - 9 1/4"7' - 9 1/4"TOP OF GARAGE FOUNDATION TO DROP 6" FROM THE TOP OF HOUSE FOUNDATIONTO OF GARAGE FOUNDATION WALL TO MATCH TOP OF HOUSE FOUNDATION WALL18' - 2"6'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.VERIFY ON SITE 8' - 0"5' - 9 1/4"2' - 4 3/4"25' - 9 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAYØ14"Ø20"Ø20"6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 5'-0" BELOW GRADE (TYP.)THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNERMUSTVERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:TOTAL:LOWER:REV.6REV. 7REV. 8REV. 9REV. 10REV. 11PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337952-953-4000ONETENTENHOMES.COMRELEASED11/30/2022 2:26:22 PMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-401OTT33211.23.22 CB12111195887329311.17.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR10.12.22 CBTHE PAYTON PLATINUM-TRADITIONAL1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UNEXCAVATEDFURNACESUMPW. H.F. D.62/8 x 6/8R.O. 2' -10" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"FAMILY ROOMBEDROOM #5CLOSETMECH. /STORAGE27' - 6"22' - 6"18' - 2"25' - 4"1' - 10"19' - 10"20' - 2"11' - 0"17' - 4"31' - 2"48' - 6"30' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.SMOKEDET.20' - 3 1/2"3' - 8"3' - 8"15' - 10 1/2"0' - 4"2' - 0"20' - 6"BATH52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"11' - 8"16' - 10"14' - 0"5' - 10"28' - 2"2' - 0"11' - 8"16' - 6"UNEXCAVATED50' - 0"50' - 0"48' - 6"5' - 0"43' - 6"14' - 0"29' - 6"7' - 11 1/4"2' - 4"R & SH.10' - 0 1/4"3' - 8"76036 NVPWGR.O. 6' -0" x 3' -6"H.H. 6' -10"6' - 9"7' - 3"20' - 9"8' - 9"65036E NVG1R.O. 5' -0" x 3' -6"H.H. 6' -10"3-2x10 W/2 TRIMMERSSMOKEDET.0' - 2"INSULATE BETWEEN WALL & SLAB8' - 2 1/2"3' - 5 1/2"3' - 10 1/4"12' - 9 3/4"32/4 x 6/8R.O. 2' -6" x 6' -11"28' - 4"4'-6" VANITY48" F.G. SHWR22/0 x 6/8R.O. 2' -2" x 6' -11"LINEN2-9 1/2" LSLW/ 2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x1043' - 6" BRACED WALL LINE SPACING26' - 0" BRACED WALL LINE SPACINGB.W.P.4' - 0"B.W.P.2' - 8"B.W.P.4' - 0"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGAIR EX.SCREEN PORCH ABOVE 2x10 TRT'D@ 16" O.C.20' - 0"10' - 0"3' - 6"10' - 0"0' - 2 3/4"9' - 6 1/2"0' - 2 3/4"3' - 3 1/4"0' - 2 3/4"0' - 2 3/4"7' - 9 1/4"8' - 0"TOP OF GARAGE FOUNDATION TO DROP 6" FROM THE TOP OF HOUSE FOUNDATIONW.S.3' - 9 1/4"2' - 2 3/4"6' - 0"2-2x62-2x63 TRIMMERS 2-2x103-2x10 TRT'D2-2x10 TRT'D2-2x10 TRT'DB.W.P.2' - 8"0' - 6"3-2x63-2x66x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 5'-0" BELOW GRADE (TYP.)THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNERMUSTVERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:TOTAL:LOWER:REV.6REV. 7REV. 8REV. 9REV. 10REV. 11PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337952-953-4000ONETENTENHOMES.COMRELEASED11/30/2022 2:26:24 PMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-402OTT33211.23.22 CB12111195887329311.17.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR10.12.22 CBTHE PAYTON PLATINUM-TRADITIONAL1/4" = 1'-0"A-4021LOWER FLOOR PLANFAN
30' - 0"20' - 0"50' - 0"6' - 0"29' - 6"14' - 0"48' - 6"93/0 x 6/8R.O. 3' -2" x 6' -10 1/4"32/4 x 6/8R.O. 2' -6" x 6' -11"36" REFKITCHENDINING ROOMGREAT ROOMFOYEROFFICESINKDWGARAGEPORCH23050 NVH2R.O. 6' -0" x 5' -0"H.H. 6' -10"2' - 0"28' - 0"17' - 4"31' - 2"20' - 2"11' - 0"9' - 0"18' - 6"2' - 0"6' - 3"7' - 9"50' - 0"6' - 0"48' - 6"2' - 1"16' - 0"2' - 1"1' - 6"8' - 0"1' - 6"0' - 6"10' - 2"6' - 8"SMOKEDET.4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSGARAGE PLATE HEIGHT TO BE 10' -7 1/8"1616' x 8' O.H. GARAGE DOOR158' x 8' O.H. GARAGE DOOR2-11 7/8" LSL3' - 4 3/4"7' - 0"3' - 6"6' - 0"4' - 0"134/0 x 6/8 OPG.12" CANT. ABOVE3' - 10"8' - 3"5' - 9"SEE COLUMNDETAIL, SHEET A-50125' - 8"17' - 10"8' - 2"17' - 6"4' - 4"5' - 10"0' - 10"15' - 0"15' - 10 1/2"3' - 8"3' - 8"20' - 3 1/2"11' - 6"16' - 6"6' - 0 1/4"7' - 1 1/2"2' - 6"3-11 7/8" LVL FLUSH2-2x10 DROPPED 17' - 6"12" x 12" GYP.BD. SOFFITPOWDERPED. SINK43636 NVH1R.O. 3' -6" x 3' -6"H.H. 6' -10"55" ELECTRIC FIREPLACE SET18" A.F.F. & STANDARD MANTLE27' - 6"22' - 6"72/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"16' - 8"11' - 4"PANTRY32/4 x 6/8R.O. 2' -6" x 6' -11"2' - 0"20' - 6"2-2x1222' - 4"5' - 8"16" SH.5' - 0"43' - 6"KNEE WALL W/ 14"PAINTED SPINDLES1' - 4"4' - 0"2' - 0"20' - 0"145/0 x 6/8R.O. 5' -2" x 6' -11"24" CAN'T. ABOVE28' - 0"R & SH.6' - 0"14' - 0"7' - 5 3/4"EQEQ124/0 x 6/8R.O. 4' -2" x 6' -11"7' - 0"0' - 6"5' - 6"2-2x10 W/2 TRIMMERS2-2x102-2x10 W/2 TRIMMERS 2-2x102-2x1082/8 x 6/8 FULL VIEWR.O. 2' -10" x 6' -11"56' - 0"44' - 6" BRACED WALL LINE SPACING18' - 0" BRACED WALL LINE SPACING28' - 0" BRACED WALL LINE SPACING17' - 4" BRACED WALL LINE SPACING27' - 2" BRACED WALL LINE SPACING18' - 0" BRACED WALL LINE SPACING28' - 0" BRACED WALL LINE SPACINGMETHOD GB WALL PANELSNAILS OR SCREWS PER TABLER702.3.5 @ 7" O.C. IN FIELD& AT PANEL EDGES (BOTHSIDES OF FRAMING)B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.6' - 8"B.W.P.6' - 8"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.2' - 8"(METHOD G.B.)4' - 0" B.W.P.(METHOD G.B.)15' - 0" B.W.P.2' - 0"2' - 0"9" HEAT DUCT33060 NVH3 ER.O. 9' -0" x 6' -0"H.H. 8' -0"113/0 x 6/8 SCREEN DOORSCREEN PORCH20' - 0"10' - 0"13' - 6"0' - 6"HALF WALL W/ SCREEN ABOVE 30" ELECTRIC RANGE W/ WOOD HOOD ABOVE 3' - 0"1' - 0"MFG. ROOF TRUSSES@ 24" O.C.103/0 x 6/8 FULL VIEWR.O. 3' -1" x 6' -8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.6' - 8"R & SH.8' - 0"3' - 6"MUD ROOM2' - 7"6' - 11 3/4"10' - 6"3:5/12 VAULTBENCH W/HOOKSFAN2-2x1018" FLOOR TRUSSESPER MFG. SPACING2-2x10 FULL LENGTH 2-2x10 FULL LENGTH 2-2x10 W/ 2 TRIMMERS 3-9 1/2" LSL 2-2x62-2x62-2x103-2x63-2x63-2x63-2x6PFH2' - 1"PFH2' - 1"PFH1' - 6"56' - 0"5' - 0"5' - 0"4' - 0"4' - 0"B.W.P.6' - 0"B.W.P.2' - 8"B.W.P.4' - 0"1/4" = 1'-0"A-4041MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNERMUSTVERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:TOTAL:LOWER:REV.6REV. 7REV. 8REV. 9REV. 10REV. 11PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337952-953-4000ONETENTENHOMES.COMRELEASED11/30/2022 2:26:27 PMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-404OTT33211.23.22 CB12111195887329311.17.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR10.12.22 CBTHE PAYTON PLATINUM-TRADITIONALBWPsAboveBWPsAboveFANLet porch beaminto house wall tobear on foundation.
OFFICE #2BEDROOM #3OWNER'S SUITEHALL11' - 6"8' - 10"23' - 2"43' - 6"R & SH.53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"1/2 WALL W/ CAP5' - 6"6' - 8 1/4"8' - 6 3/4"8' - 9"7' - 0"7' - 0"29' - 6"14' - 0"5' - 9"5' - 9"4' - 5"4' - 5"SMOKEDET.SMOKEDET.SMOKEDET.EN SUITE6' VANITYRAILING52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"12424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"28' - 0"2' - 0"1' - 0"2' - 0"15' - 10"0' - 10"5' - 0"4' - 4"13' - 7 3/4"9' - 2 1/4"4' - 0"6' - 0"10' - 8"9' - 1 3/4"4' - 1 1/8"7' - 0 5/8"5' - 7 3/4"2' - 4"3' - 8"BEDROOM #211' - 0"2' - 6"14' - 6"CO DET.SMOKEDET.ATTICACCESS2-2x1011' - 4"7' - 8"10' - 0"53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"43' - 6"28' - 0"32/4 x 6/8R.O. 2' -6" x 6' -11"42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"5'-6" VANITY42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"5' TUB/SHWRJ&J BATH124/0 x 6/8R.O. 4' -2" x 6' -11"LAUNDRY6' - 0"7' - 7 3/4"2' - 2 3/4"L.T.HEAD 3-2x10 W/2 TRIMMERS3-2x10 W/2 TRIMMERS26' - 0" BRACED WALL LINE SPACING43' - 6" BRACED WALL LINE SPACING2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.4' - 0" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.31' - 0"29' - 0"31' - 0"TYP.2' - 0"BOX VAULT 32/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.R & SH.R & SH.3' - 10"2' - 9"3' - 3 1/2"6' - 0"20' - 3 1/2"3' - 8"3' - 8"15' - 10 1/2"2' - 4"CURBCONTROL TILE SHOWER 145/0 x 6/8R.O. 5' -2" x 6' -11"R & SH.R & SH.5' - 0 1/4"2' - 6"8' - 10"12424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"32/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.R & SH.CLOSETOWNER'SCLOSETMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.GIRDER TRUSS MFG. ROOF TRUSSES@ 24" O.C.1LINEN53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"SMOKEDET.WASHERDRYERGIRDER TRUSS 2x62-2x102-2x102-2x103-2x63-2x63-2x63-2x62' - 3" B.W.P.2' - 0" B.W.P.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNERMUSTVERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:TOTAL:LOWER:REV.6REV. 7REV. 8REV. 9REV. 10REV. 11PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337952-953-4000ONETENTENHOMES.COMRELEASED11/30/2022 2:26:29 PMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-405OTT33211.23.22 CB12111195887329311.17.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR10.12.22 CBTHE PAYTON PLATINUM-TRADITIONAL1/4" = 1'-0"A-4051UPPER FLOOR PLAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FANFAN
WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTSTANDARD ENERGY HEELS & 7:12 ROOF SLOPE W/ 8:12 FASCIA LINES TO MATCH 18" OVERHANGS & 12" RAKES TYPICAL7 ROOF VENTS @ HOUSE STANDARD ENERGY HEELS @ 6:12 ROOF SLOPEW/ 8:12 FASCIA LINES TO MATCH 18" OVERHANGS & 12" RAKES TYPICAL.7" / 12"7" / 12"6" / 12"8" / 12"8" / 12"7" / 12"7" / 12"7" / 12"7" / 12"8" / 12"8" / 12"1 ROOF VENT 4 ROOF VENTS @ GARAGE 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER1' - 2"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNERMUSTVERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:TOTAL:LOWER:REV.6REV. 7REV. 8REV. 9REV. 10REV. 11PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337952-953-4000ONETENTENHOMES.COMRELEASED11/30/2022 2:26:32 PMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-501OTT33211.23.22 CB12111195887329311.17.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR10.12.22 CBTHE PAYTON PLATINUM-TRADITIONAL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2424 AWN 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 3050 NVH2 6' - 0" 5' - 0" 6' - 10"3 VECTOR ENVISION SERIES 1 3060 NVH3 E 9' - 0" 6' - 0" 8' - 0"4 VECTOR ENVISION SERIES 1 3636 NVH1 3' - 6" 3' - 6" 6' - 10"5 VECTOR ENVISION SERIES 4 3650E NVH2 7' - 0" 5' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 5036E NVG1 5' - 0" 3' - 6" 6' - 10"7 VECTOR ENVISION SERIES 1 6036 NVPWG 6' - 0" 3' - 6" 6' - 10"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR PLAN MECH. / STORAGE 201 SF 8' - 2"LOWER FLOOR PLAN FAMILY ROOM 451 SF 8' - 2" .LOWER FLOOR PLAN BEDROOM #5 183 SF 8' - 2" .LOWER FLOOR PLAN CLOSET 85 SF 8' - 2" .LOWER FLOOR PLAN BATH 48 SF 8' - 2" .MAIN FLOOR OFFICE 104 SF 9' - 1 1/8"MAIN FLOOR MUD ROOM 97 SF 9' - 1 1/8"MAIN FLOOR GARAGE 627 SF 10' - 7 7/8"MAIN FLOOR POWDER 27 SF 9' - 1 1/8"MAIN FLOOR SCREEN PORCH 68 SF 9' - 1 1/8" VAULTMAIN FLOOR KITCHEN 214 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM 211 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM 248 SF 9' - 1 1/8" .MAIN FLOOR FOYER 78 SF 9' - 1 1/8" .MAIN FLOOR PANTRY 28 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #3 107 SF 8' - 1 1/8"UPPER FLOOR HALL 114 SF 8' - 1 1/8"UPPER FLOOR BEDROOM #2 137 SF 8' - 1 1/8"UPPER FLOOR OWNER'S CLOSET 68 SF 8' - 1 1/8"UPPER FLOOR J&J BATH 60 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY 74 SF 8' - 1 1/8"UPPER FLOOR CLOSET 47 SF 8' - 1 1/8"UPPER FLOOR OFFICE #2 98 SF 8' - 1 1/8"UPPER FLOOR OWNER'S SUITE 198 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR EN SUITE 95 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 1/6 x 6/8 1' - 8" 6' - 11" 12 2/0 x 6/8 2' - 2" 6' - 11" 13 2/4 x 6/8 2' - 6" 6' - 11" 74 2/4 x 6/8 PKT 4' - 10" 6' - 11" 35 2/6 x 6/8 2' - 8" 6' - 11" 66 2/8 x 6/8 2' - 10" 6' - 11" 27 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 18 2/8 x 6/8 FULL VIEW 2' - 10" 6' - 11" 19 3/0 x 6/8 3' - 2" 6' - 10 1/4" 110 3/0 x 6/8 FULL VIEW 3' - 1" 6' - 8" 111 3/0 x 6/8 SCREEN DOOR 112 4/0 x 6/8 4' - 2" 6' - 11" 213 4/0 x 6/8 OPG. 114 5/0 x 6/8 5' - 2" 6' - 11" 215 8' x 8' O.H. GARAGE DOOR 116 16' x 8' O.H. GARAGE DOOR 11/8" = 1'-0"A-5011ROOF PLAN1/2" = 1'-0"A-5014TYP. WALKOUT SECTION1/2" = 1'-0"A-5015TYP. LOOKOUT SECTION1/2" = 1'-0"A-5016TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5017TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5018BEARING WALL SECTION3/8" = 1'-0"A-5019METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. HOUSE FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARGE PLATE HEIGHT 10' - 7 1/8"ALUMINUM SOFFIT & FASCIA TYP.6" SMARTSIDETRIM TYP.VINYL BOARD & BATTEN TYP.VINYLLAP SIDING TYP.SEE COLUMNDETAIL, SHEET A-501CULTURED STONEW/ CONCRETE CAP 3' - 6"ADDRESS STONE3 PHOTO CELLS LIGHTS @ FRONTGARAGE PLATE10' -1 1/8"6" SMARTSIDE FREIZE BOARD TYP. T.O. GARAGE FOUNDATION-0' -6"0' - 6"7" / 12"6" / 12"8" 12"8" 12"0' - 8 1/4"24" RETURNS7" 12"8" / 12"7" / 12"7" / 12"8" / 12"ALUMINUM SOFFIT& FASCIAVINYL SIDING& CORNERS7" / 12"7" 12"7" 12"7" 12"7" / 12"8" / 12"8" / 12"6" 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/26/2022 10:24:47 AMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-201OTT33210.13.22 CB1211119588710.13.22 CB10.18.22 CB10.26.22 CB10.12.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR3293THE PAYTON PLATINUM-TRADITIONAL1/8" = 1'-0"A-2012LEFT ELEVATION1/8" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014RIGHT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-404 MAIN FLOORA-405 UPPER FLOORA-501 ROOF PLAN/ DETAILS/ SCHEDULE
27' - 6"22' - 6"18' - 2"25' - 4"1' - 10"19' - 10"17' - 4"31' - 2"48' - 6"30' - 2"19' - 10"16' - 8"11' - 10"0' - 4"1' - 4 1/2"8' - 3" M.O.1' - 4 1/2"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"2' - 0"20' - 6"14' - 0"5' - 10"28' - 2"2' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.50' - 0"50' - 0":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE14' - 0"29' - 6"5' - 0"43' - 6"48' - 6"4' - 0 5/8"6' - 9 3/8"15' - 6"15' - 7 3/4"3' - 10 3/4"3' - 10 3/4"20' - 0 3/4"28' - 4"11' - 0"20' - 2"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.* ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATION* ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATION15' - 6"1' - 0"11' - 8"0' - 2"LEAVE A 12" GAP IN FOOTING FOR PLUMBING 8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 14" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN FOOTING FOR PLUMBING 10' - 2 3/4"3' - 6"0' - 3 1/4"9' - 3 1/4"20' - 2 3/4"2' - 0"3' - 9 1/4"7' - 9 1/4"TOP OF GARAGE FOUNDATION TO DROP 6" FROM THE TOP OF HOUSE FOUNDATIONTO OF GARAGE FOUNDATION WALL TO MATCH TOP OF HOUSE FOUNDATION WALLTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/26/2022 10:24:49 AMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-401OTT33210.13.22 CB1211119588710.13.22 CB10.18.22 CB10.26.22 CB10.12.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR3293THE PAYTON PLATINUM-TRADITIONAL1/4" = 1'-0"A-4011FOUNDATION PLAN
UNEXCAVATEDFURNACESUMPW. H.F. D.62/8 x 6/8R.O. 2' -10" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"FAMILY ROOMBEDROOM #5CLOSETMECH. /STORAGE27' - 6"22' - 6"18' - 2"25' - 4"1' - 10"19' - 10"20' - 2"11' - 0"17' - 4"31' - 2"48' - 6"30' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.SMOKEDET.20' - 3 1/2"3' - 8"3' - 8"15' - 10 1/2"0' - 4"2' - 0"20' - 6"BATH52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"11' - 8"16' - 10"14' - 0"5' - 10"28' - 2"2' - 0"11' - 8"16' - 6"UNEXCAVATED50' - 0"50' - 0"48' - 6"5' - 0"43' - 6"14' - 0"29' - 6"7' - 11 1/4"2' - 4"R & SH.10' - 0 1/4"3' - 8"76036 NVPWGR.O. 6' -0" x 3' -6"H.H. 6' -10"6' - 9"7' - 3"20' - 9"8' - 9"65036E NVG1R.O. 5' -0" x 3' -6"H.H. 6' -10"3-2x10 W/2 TRIMMERSSMOKEDET.0' - 2"INSULATE BETWEEN WALL & SLAB8' - 2 1/2"3' - 5 1/2"3' - 10 1/4"12' - 9 3/4"32/4 x 6/8R.O. 2' -6" x 6' -11"28' - 4"4'-6" VANITY48" F.G. SHWR22/0 x 6/8R.O. 2' -2" x 6' -11"LINEN2-9 1/2" LSLW/ 2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x1043' - 6" BRACED WALL LINE SPACING26' - 0" BRACED WALL LINE SPACINGB.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGAIR EX.SCREEN PORCH ABOVE 2x10 TRT'D@ 16" O.C.20' - 0"10' - 0"3' - 6"10' - 0"0' - 2 3/4"9' - 6 1/2"0' - 2 3/4"0' - 2 3/4"7' - 9 1/4"8' - 0"TOP OF GARAGE FOUNDATION TO DROP 6" FROM THE TOP OF HOUSE FOUNDATIONW.S.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/26/2022 10:24:51 AMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-402OTT33210.13.22 CB1211119588710.13.22 CB10.18.22 CB10.26.22 CB10.12.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR3293THE PAYTON PLATINUM-TRADITIONAL1/4" = 1'-0"A-4021LOWER FLOOR PLANHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***2-2x62-2x62-2x103-2x10 Trtd.2-2x10 Trtd.2-2x10 Trtd.2 Trimmers3 Trimmers
6' - 0"30' - 0"20' - 0"56' - 0"29' - 6"14' - 0"48' - 6"93/0 x 6/8R.O. 3' -2" x 6' -10 1/4"32/4 x 6/8R.O. 2' -6" x 6' -11"36" REFKITCHENDINING ROOMGREAT ROOMFOYEROFFICESINKDWGARAGEPORCH23050 NVH2R.O. 6' -0" x 5' -0"H.H. 6' -10"2' - 0"28' - 0"17' - 4"31' - 2"20' - 2"11' - 0"9' - 0"18' - 6"2' - 0"6' - 3"7' - 9"56' - 0"48' - 6"2' - 1"16' - 0"2' - 1"1' - 6"8' - 0"1' - 6"0' - 6"10' - 2"7' - 2"SMOKEDET.4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TO BE 10' -7 1/8"1616' x 8' O.H. GARAGE DOOR158' x 8' O.H. GARAGE DOOR2-11 7/8" LSL3' - 4 3/4"7' - 0"3' - 6"6' - 0"4' - 0"134/0 x 6/8 OPG.12" CANT. ABOVE3' - 10"8' - 3"5' - 9"SEE COLUMNDETAIL, SHEET A-50125' - 8"17' - 10"8' - 2"17' - 6"4' - 4"5' - 10"0' - 10"15' - 0"15' - 10 1/2"3' - 8"3' - 8"9' - 7 3/4"10' - 7 3/4"11' - 6"16' - 6"6' - 0 1/4"7' - 1 1/2"2' - 8 3/4"3-11 7/8" LVL FLUSH2-2x1017' - 6"12" x 12" GYP.BD. SOFFITPOWDERPED. SINK43636 NVH1R.O. 3' -6" x 3' -6"H.H. 6' -10"55" ELECTRIC FIREPLACE SET18" A.F.F. & STANDARD MANTLE6' - 0"27' - 6"22' - 6"72/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"16' - 8"11' - 4"PANTRY32/4 x 6/8R.O. 2' -6" x 6' -11"2' - 0"20' - 6"2-2x1222' - 4"5' - 8"16" SH.5' - 0"43' - 6"KNEE WALL W/ 14"PAINTED SPINDLES1' - 4"4' - 0"2' - 0"20' - 0"145/0 x 6/8R.O. 5' -2" x 6' -11"24" CAN'T. ABOVE28' - 0"R & SH.6' - 0"14' - 0"7' - 5 3/4"EQEQ124/0 x 6/8R.O. 4' -2" x 6' -11"7' - 0"0' - 6"5' - 6"2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-2x1082/8 x 6/8 FULL VIEWR.O. 2' -10" x 6' -11"18' - 0"28' - 0"44' - 6" BRACED WALL LINE SPACING18' - 0" BRACED WALL LINE SPACING28' - 0" BRACED WALL LINE SPACING17' - 4" BRACED WALL LINE SPACING27' - 2" BRACED WALL LINE SPACING18' - 0" BRACED WALL LINE SPACING28' - 0" BRACED WALL LINE SPACINGMETHOD GB WALL PANELSNAILS OR SCREWS PER TABLER702.3.5 @ 7" O.C. IN FIELD& AT PANEL EDGES (BOTHSIDES OF FRAMING)B.W.P.2' - 8"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.6' - 8"PFH BRACEDWALL PANELPFH BRACEDWALL PANELPFH BRACEDWALL PANELB.W.P.6' - 8"B.W.P.6' - 8"B.W.P.6' - 8"B.W.P.6' - 8"B.W.P.2' - 8"(METHOD G.B.)4' - 0" B.W.P.(METHOD G.B.)15' - 0" B.W.P.2' - 0"2' - 0"9" HEAT DUCT33060 NVH3 ER.O. 9' -0" x 6' -0"H.H. 8' -0"113/0 x 6/8 SCREEN DOORSCREEN PORCH20' - 0"10' - 0"13' - 6"0' - 6"HALF WALL W/ SCREEN ABOVE 30" ELECTRIC RANGE W/ WOOD HOOD ABOVE 3' - 0"1' - 0"MFG. ROOF TRUSSES@ 24" O.C.103/0 x 6/8 FULL VIEWR.O. 3' -1" x 6' -8"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.6' - 8"R & SH.8' - 0"3' - 6"MUD ROOM2' - 10 1/4"6' - 11 3/4"10' - 6"3:5/12 VAULTBENCH W/HOOKSFAN1/4" = 1'-0"A-4041MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/26/2022 10:24:53 AMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-404OTT33210.13.22 CB1211119588710.13.22 CB10.18.22 CB10.26.22 CB10.12.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR3293THE PAYTON PLATINUM-TRADITIONALHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***3-2x63-2x63-2x63-2x63-9 1/2" LSL2-2x10 w/2 Trimmers2-2x10 Full Length2-2x10 Full Length2-2x10 Full LengthX X X X X X X X2 Trimmers2-2x102-2x10
OFFICE #2BEDROOM #3OWNER'S SUITEHALL11' - 6"8' - 10"23' - 2"43' - 6"R & SH.53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"1/2 WALL W/ CAP5' - 6"6' - 8 1/4"8' - 6 3/4"8' - 9"7' - 0"7' - 0"29' - 6"14' - 0"5' - 9"5' - 9"4' - 5"4' - 5"SMOKEDET.SMOKEDET.SMOKEDET.EN SUITE6' VANITYRAILING52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"12424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"28' - 0"2' - 0"1' - 0"2' - 0"15' - 10"0' - 10"5' - 0"4' - 4"13' - 7 3/4"9' - 2 1/4"4' - 0"6' - 0"10' - 8"9' - 1 3/4"4' - 1 1/8"7' - 0 5/8"5' - 7 3/4"6' - 0"BEDROOM #211' - 0"2' - 6"14' - 6"CO DET.SMOKEDET.ATTICACCESS2-2x1011' - 4"7' - 8"10' - 0"53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"43' - 6"28' - 0"32/4 x 6/8R.O. 2' -6" x 6' -11"42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"5'-6" VANITY42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"5' TUB/SHWRJ&J BATH124/0 x 6/8R.O. 4' -2" x 6' -11"LAUNDRY6' - 0"7' - 7 3/4"2' - 2 3/4"L.T.HEAD 2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS26' - 0" BRACED WALL LINE SPACING43' - 6" BRACED WALL LINE SPACING2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.4' - 0" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.31' - 0"29' - 0"31' - 0"TYP.2' - 0"BOX VAULT 32/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.R & SH.R & SH.3' - 10"2' - 9"3' - 3 1/2"6' - 0"20' - 3 1/2"3' - 8"3' - 8"15' - 10 1/2"2' - 4"CURBCONTROL TILE SHOWER 145/0 x 6/8R.O. 5' -2" x 6' -11"R & SH.R & SH.5' - 0 1/4"2' - 6"8' - 10"12424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"32/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.R & SH.CLOSETOWNER'SCLOSETMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.GIRDER TRUSS MFG. ROOF TRUSSES@ 24" O.C.1LINEN53650E NVH2R.O. 7' -0" x 5' -0"H.H. 6' -10"SMOKEDET.WASHERDRYERGIRDER TRUSS THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/26/2022 10:24:55 AMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-405OTT33210.13.22 CB1211119588710.13.22 CB10.18.22 CB10.26.22 CB10.12.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR3293THE PAYTON PLATINUM-TRADITIONAL1/4" = 1'-0"A-4051UPPER FLOOR PLANHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***3-2x102-2x103-2x103-2x63-2x63-2x63-2x62-2x102-2x10
WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTSTANDARD ENERGY HEELS & 7:12 ROOF SLOPE W/ 8:12 FASCIA LINES TO MATCH 18" OVERHANGS & 12" RAKES TYPICAL7 ROOF VENTS @ HOUSE STANDARD ENERGY HEELS @ 6:12 ROOF SLOPEW/ 8:12 FASCIA LINES TO MATCH 18" OVERHANGS & 12" RAKES TYPICAL.7" / 12"7" / 12"6" / 12"8" / 12"8" / 12"7" / 12"7" / 12"7" / 12"7" / 12"8" / 12"8" / 12"1 ROOF VENT 4 ROOF VENTS @ GARAGE 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER1' - 2"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/26/2022 10:24:58 AMTHE MORRISSEY RESIDENCEL3, B1 -GLACIER CREEK 2ND ADDITION18253 GLACIER WAYLAKEVILLE, MNA-501OTT33210.13.22 CB1211119588710.13.22 CB10.18.22 CB10.26.22 CB10.12.22 CB8' - 1 1/8"9' - 1 1/8"8'-4" POUR3293THE PAYTON PLATINUM-TRADITIONAL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2424 AWN 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 3050 NVH2 6' - 0" 5' - 0" 6' - 10"3 VECTOR ENVISION SERIES 1 3060 NVH3 E 9' - 0" 6' - 0" 8' - 0"4 VECTOR ENVISION SERIES 1 3636 NVH1 3' - 6" 3' - 6" 6' - 10"5 VECTOR ENVISION SERIES 4 3650E NVH2 7' - 0" 5' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 5036E NVG1 5' - 0" 3' - 6" 6' - 10"7 VECTOR ENVISION SERIES 1 6036 NVPWG 6' - 0" 3' - 6" 6' - 10"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR PLAN MECH. / STORAGE 201 SF 8' - 2"LOWER FLOOR PLAN FAMILY ROOM 451 SF 8' - 2" .LOWER FLOOR PLAN BEDROOM #5 183 SF 8' - 2" .LOWER FLOOR PLAN CLOSET 85 SF 8' - 2" .LOWER FLOOR PLAN BATH 48 SF 8' - 2" .MAIN FLOOR OFFICE 104 SF 9' - 1 1/8"MAIN FLOOR MUD ROOM 97 SF 9' - 1 1/8"MAIN FLOOR GARAGE 627 SF 10' - 7 7/8"MAIN FLOOR POWDER 27 SF 9' - 1 1/8"MAIN FLOOR SCREEN PORCH 68 SF 9' - 1 1/8" VAULTMAIN FLOOR KITCHEN 214 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM 211 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM 248 SF 9' - 1 1/8" .MAIN FLOOR FOYER 78 SF 9' - 1 1/8" .MAIN FLOOR PANTRY 28 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #3 107 SF 8' - 1 1/8"UPPER FLOOR HALL 114 SF 8' - 1 1/8"UPPER FLOOR BEDROOM #2 137 SF 8' - 1 1/8"UPPER FLOOR OWNER'S CLOSET 68 SF 8' - 1 1/8"UPPER FLOOR J&J BATH 60 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY 74 SF 8' - 1 1/8"UPPER FLOOR CLOSET 47 SF 8' - 1 1/8"UPPER FLOOR OFFICE #2 98 SF 8' - 1 1/8"UPPER FLOOR OWNER'S SUITE 198 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR EN SUITE 95 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 1/6 x 6/8 1' - 8" 6' - 11" 12 2/0 x 6/8 2' - 2" 6' - 11" 13 2/4 x 6/8 2' - 6" 6' - 11" 74 2/4 x 6/8 PKT 4' - 10" 6' - 11" 35 2/6 x 6/8 2' - 8" 6' - 11" 66 2/8 x 6/8 2' - 10" 6' - 11" 27 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 18 2/8 x 6/8 FULL VIEW 2' - 10" 6' - 11" 19 3/0 x 6/8 3' - 2" 6' - 10 1/4" 110 3/0 x 6/8 FULL VIEW 3' - 1" 6' - 8" 111 3/0 x 6/8 SCREEN DOOR 112 4/0 x 6/8 4' - 2" 6' - 11" 213 4/0 x 6/8 OPG. 114 5/0 x 6/8 5' - 2" 6' - 11" 215 8' x 8' O.H. GARAGE DOOR 116 16' x 8' O.H. GARAGE DOOR 11/8" = 1'-0"A-5011ROOF PLAN1/2" = 1'-0"A-5014TYP. WALKOUT SECTION1/2" = 1'-0"A-5015TYP. LOOKOUT SECTION1/2" = 1'-0"A-5016TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5017TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5018BEARING WALL SECTION3/8" = 1'-0"A-5019METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
12/15/22 X
PM