Loading...
HomeMy WebLinkAboutLA209506 - 17072 Draft Horse Blvd Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014CCC1'-0"1'-4"1'-0"1'-4"6:126:128' RIDGE VENT1'-0"1'-4"1'-0"1'-4" 1'-0"1'-4"1'-0"1'-4"6:126:126:128:128:12AABBBBAACC36' RIDGE VENT16' RIDGE VENT 8:128:129' RIDGE VENT 1'-4"ROOF PLAN1/8"=1'-0"AT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" TRIM 3 1/2" TRIM 5" TRIM5" TRIM1-1/2"1"HARDBOARD TRIMHARD BOARD SIDINGHARD BOARD SIDING2-SIDED OUTSIDE CORNER2-3/4" .96"3-1/2"SHEATHINGHDBD TRIM 1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-72725465-B-3.0HARRISON5465 B-FRONTHARRISONTOTAL FRONT FASCADE: 607 SQ FTSTONE: 152 SQ FT- 25.1%VINYL SHAKES: 90 SQ FT-14.8%DRAWN: 12-4-2015-AWSPEC HOMECUST:PC#842: 1-1-2021-LLPC#984,971,967: 3-29-2022-RKPC#1038,1039: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AFREFAVINYL LAP SIDINGPRODUCTCBD5/4X6 CEMENT BD. TRIMREFMATERIAL LEGENDECEMENT BD. SIDINGPRODUCTGFHCEMENT BD. SHAKES5/4X8 CEMENT BD TRIMNOT USEDNOT USEDC.B. BOARD-N-BATTENA6:12 PITCH8" TRIM1xXXXXXADDRESS NUMBERSTEEL PANEL OVERHEAD DOORICE & WATERALUMINUM FLASHINGBEHIND STOOPBA1'-4"10 3/16"8126:12 PITCH6:12 PITCHD1'-0"8" TRIM2"AT ALL GABLES, OROSB SHEATHINGWHEREVER SHAKES& BOARD-N-BATTENMATERIAL IS USEDRAIN DIVERTER6'-4"1'-4"2'-0"3'-2" WOODGRAIN PANEL5/4" x 5" - WOODGRAIN5/4" x 10" - WOODGRAINWOODGRAIN PANEL4/4" x 3" - WOODGRAIN(FRONT & REAR)6x6 POSTBLOCKING2x4 TREATED1/2" OSB4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)4/4" x 2" - WOODGRAINCORNER TRIM11 1/4" AT TOP 11 1/4" AT TOP1'-4"11 1/4"3'-5"1/2" OSBOVER 2xTREATED FRAMEBEAM1/2" OSBOVER 2xTREATED FRAMEWOODGRAINPANELWOODGRAIN5/4" x 10"FLASHINGSTONE CAPSTONE CAPTAPERED COLUMN WITHSTONE PIER1/4"=1'-0"1/4"=1'-0"2"=1'-0"2"=1'-0"(SIDES)16" AT BASE16" AT BASE30°29'-8 11/16"B1x CEDAR1'-0"1'-0"6:12 PITCHLEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"FLASH OVER ALL EXT OPGSASPHALT SHINGLESA6:12 PITCHA1'-0"40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.26126121'-4"7 7/16"1'-4"7 7/16"A8:12 PITCH6121'-4"7 7/16"6128:12 PITCH42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEMAINTAIN 6" MIN SEPARATION WOOD to EARTH1'-0"7 7/16"1'-4"7 7/16"612612A1'-4"A1261'-4"PERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIRESecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/28/2022dmathews 4'-4"EGRESS WDW4'-3"DROP EGRESS FOUNDATION 6"SLEEVEDRAIN TILE36'-0"6'-8" 42'-8"24'-4"39'-0"6'-0"4'-2"8'-2"11'-10"4'-4 1/2"13'-6 1/2"13'-7 1/4"3 1/2"FUTUREFAMILY RMUP16RUNEXCAVATED3'-8"15'-10"FUTUREBEDRMBASEMENT PLAN1/4"=1'-0"TYP. WINDOW HEAD HEIGHT AT 7'-0" U.N.O.NOTE:8'-4" HIGH POURED CONC. FOUNDATION WALL TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR18" MFD FLOOR TRUSSES INSTALL PER MFRS SPECS 16"x8" CONC. FTG.NOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONS10" TREAD CUT POURED CONC. WALL8" THICK, 8'-4" HIGH16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE16'-0"6'-0"POURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGHANCHORS AT 6'-0" O.C.BLOCK AT MIDPOINT14x8 CONC FTG6" HALF-HIGH CURBTREATED BOTTOM PLATE2x6 STUDS AT 16" O.C.2x6 BRNG WALL2x6 BRNG WALL2-8HDR4'-2"These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C2.0X18" MFD FLOOR TRUSSES INSTALL PER MFRS SPECS 16'-6"19'-6" 12'-0" COCK SILLSUMP WHF.D.MECH./STORAGEACHV8'-2"12'-2"2-68'-0"3'-10"4'-0"154 SQ. FT.34x48FBGL SHWR36"2'-6"5-0R/I3/4B68 SQ. FT.2-6HDR2-48"9'-9 1/4"5'-4 3/4"2X2 FURRWALL2'-1"6x6 TREATED POSTMIN. 3'-6" BELOW GRADE1/2"=1'-0"FRONT PORCH LEDGER SECTION5 3/47 1/4"7 1/4"FLASHING ABOVEDOORTHRESHOLDGRADETOP OF SUBFLOORTO TOP OF JOIST5 3/4" FROM1 1/2"AND BELOW TREATED2x8 LEDGERSTRTD 2x8 JOISTS16" O.C.(8) 10d COMMON NAILSTREATED 2x8(TOP OF FOUND TOBOTTOM OF DECK JOIST)5/4" DECKINGRIM BOARD1-1/8" OSB18" FLOOR TRUSSES(4) PER DECK, RATED AT 750 # EACHSPACED EVENLY, MAX. 24" FROM END OF LEDGERLATERAL LOAD CONNECTION:USP LTS19-TZ w/ LBP12-TZ WASHER1x10 CEDAR SKIRTAT DROPPED BEAM1x10 CEDAR SKIRTAT DECK RIM JOISTBLOCKING AS REQ.FOR SKIRT SUPPORTDROPPED BEAMUSP LTS19-TZ BRACINGAND WOOD BLOCKINGSEE PAGE 5 FOR DETAILS2x12 BLOCKING2x12 BLOCKINGPORCH SKIRT DETAIL1/4"=1'-0"1081 SQ. FT.425 SQ. FT.20'-2"TPH 24" TOWEL BAR3'-0"HARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AF4'-4"7'-2"8'-0"13'-8"14'-6"BRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEM4'-0"4'-0"BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEM4'-0"4'-0"MAX.LOOKOUT &FULL BSMNTFBS AT:LOOKOUT &FULL BSMNTFBS AT:BRACING ATFULL BSMT ONLYFOUNDATIONBRACING ATFULL BSMT ONLYFOUNDATIONWINDOW & DOOR SCHEDULE-FULLCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC2540 CSMT0.2728 3/4" X 48 1/2"#1BEDROOM0.255040 SLIDER0.2960" X 48"1FAMILY ROOM0.322540 CSMT.16'-0"24'-0"42'-0"49'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE4'-0"10'-0"POINT LOAD ABOVE30x30x12 CONC. FTG10'-0"49'-0"22x22x12CONC. PAD FTG.1/2"=1'-0"FRONT PORCH LEDGER DETAIL18" FLOOR TRUSSES 3/4" 1st FLOOR WALLSSUBFLOOR 9'-1 1/8" BASEMENT WALLS 3/4" SUBFLOOR6 1/4"7-1/4"2x8 PORCHLEDGER2x6 EXTERIOR WALL. 2""MIN...5 1/4" 2" FROM TOPLAG SCREW TO BEMIN. 2" FROM EDGE16" O.C. UNDER 10'-0" SPAN12" O.C. OVER 10'-0" SPANSUBFLOOR TOTOP OF LEDGEROF LEDGER19.2" O.C.FLOOR TRUSSESBLOCKING, LAID FLAT(2) TRTD 2x12(8) 16D NAILS ON INSIDEBLOCKING, LAID FLATTRTD (2) 2x12(8) 16D NAILS PER SIDE(8) 30D NAILS ON OUTSIDELAG SCREWS1/2" DIAMETERINSTALLED STAGGERED IN 2 ROWSLAG SCREWS W/ WASHER TO BEUSP LTS19-TZ STRAPS TO BE ATTACHED TO DECK JOISTOR 2X12 BLOCKING AND ANCHORED INTO FLOOR TRUSS.(4) STRAPS PER DECK/PORCH, RATED AT 750# EACH,TO BE SPACED EVENLY. MAX 24" FROM END OF DECK LEDGERMINIMUM 3" PENETRATION THRU OSB RIM & FLOOR TRUSS18'-4"20'-8"2'-2 1/2"2'-2 1/2"16'-3"10'-0"2'-0"6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK16"x8" FTG.POURED CONC. WALLMIN. 3'-6" BELOW GRADE16'-3" M.O.7 1/2"8'-3"1'-1 1/2"2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.18'-4"8"7'-6"10'-2"3-2x8 FLUSH BEAM3-2x8 FLUSH BEAMTREATED 2x8's 16" ON CENTER 6x6 TREATED POST18" CONC. PIER FTG.MIN. 3'-6" BELOW GRADEPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE8'-7"5'-5"8"8"CANT. JOISTSPOINT LOAD ABOVE30x30x12 CONC. FTG4'-0"POINT LOAD ABOVE30x30x12 CONC. FTGSILL COCK12'-0"(MIN. 21" DIAMETER IF CLAY SOILS)RADONVENT PIPE2'-1"30x30x12CONC. PAD FTG.SIMPSON DTT1Z ORSIMPSON DTT1Z ORSIMPSON DTT1Z OR6'-4"EGRESS WINDOWS4'-4"DROP WELL FOUNDATION 6"5040 SLIDERSLEEVEDRAIN TILEPERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIREPLAN OPTIONS2ND EGRESS WINDOW WELLUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.(2)7-1/4 Versa-LamInterior BWP Above(2)7-1/4 Versa-Lam WALL SECTION 2F1 RETAINING WALL TYPESTAIRWAY FOUNDATION WALL(3) #4 LONGITUDINAL BARSAT TOP OF FOOTING#4 HORIZ. BARS@ 24" O.C.8" MIN. C.I.P.CONCRETE WALLVERTICAL BAR OPTIONS:#5 BARS @ 24" O.C.OR #6 BARS @ 36" O.C.#4 BARS @ END &BEND OF HOOK5'-0" HOOK OPTIONS:#5 HOOKS @ 12" O.C. OR#6 HOOKS @ 18" O.C.TRANSVERSE BARS OPTIONS:#5 BARS @ 24" O.C. OR#6 BARS @ 36" O.C.10" THICK C.I.P.CONCRETE FOOTING1'-6"3'-6"2" TO VERTICAL BARS & HOOKS1'-6"4'-0"2"3"8'-4" MAX.SLAB-ON-GRADE WOOD WALL12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 48" O.C. MAX. OR EQUIV.FRAME WALL ABOVESLAB-ON-GRADE &INSULATION BY OTHERS6" MIN. C.I.P. CONCRETESTEM WALL KIT.HD-FLR6'-1 1/2"UP16RDN16R15'-10" 16'-0"6'-0" 20'-0" 36'-0"6'-0" 42'-0" 12'-0"19'-6"39'-0"20'-8"2'-8"2'-0"10'-4"10'-4"1ST FLOOR PLAN1/4"=1'-0"1081 SQ. FT.NOTE:9'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 8'-0" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRGREATROOM39'-0"6'-4"13'-4"FOYERHD-FLR16x7 OVERHEAD DOORWOOD PORCH18'-4"These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C3.0XHARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AF20'-2"10' TREAD CUT 3-03050-2 SH20 AMP.MICRO HOODCIRCUITRANGE11'-4"4'-8"3'-4"4'-2"FLUSH LVL BEAMREF.2'-3"2-0DINETTEHD-FLR4'-6" 14" MFD I-JOISTS INSTALL PER MFRS SPECS 14" MFD I-JOISTS INSTALL PER MFRS SPECS 4'-8 1/2"6'-7 1/2"2'-4"1'-4"6'-8"8'-0"4-05'-0"6'-4"10'-7 3/4"7'-0"6'-0 1/2"6'-4 1/4" DW SINK 2X4 WALLS FRAMED35" A.F.F.12" OVERHANG 6068 SGDTYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN16" TAPERED TO 12" BOXED COLUMNOVER 16" (FRAMED) SQUARE STONE BASE126 SQ. FT.14" MFD I-JOISTS INSTALL PER MFRS SPECS 3'-1"3 1/2"2x6WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC3-0 DOOR0.31#1FOYER0.232W 3050 SH1STUDY2W 3050 SH1GREAT ROOM0.310.3172 1/8" X 60 1/4"0.310.3172 1/8" X 60 1/4"3040 SH1W.I.C.0.3136 1/4" X 48"0.312'-8"3'-6"3'-3"3'-7"6'-8"4'-9 1/4"3040 SH7'-6"2-85'-9"2-44'-7 3/4"3-0 x 8-0 OPG 9'-11"1/2 BHD-FLR6'-8" TPH 24" TOWEL BARHD-FLRW.I.C.2-89'-5"9'-5"MUD RMHD-FLRPED.5'-10"2X63050-2 SH2-416'-0"24'-0"42'-0"49'-0"GARAGESLOPE TO DOORS4" CONC FLOOR686 SQ. FT.TYPICAL 2x6 GARAGE WALLS8x7 OVERHEAD DOORMFD TRUSSES AT 24" O.C. FLUSH BEAM 2'-0"10'-0"5'-3"4'-9"4'-0"10'-0"49'-0"ON ALL WALLS & CEILINGGYP. BOARDNOTE: OPTIONAL 45"COAT RACKFLOORING ATTOP LANDING TOMATCH GREAT RMDROPPED BEAM16" WIDE DROPPED SOFFIT(SEE SECTION)7'-6"10'-2"8"6'-4"6'-0"FLOOR LINE ABOVEGIRDER TRUSSPOINT LOAD FROM ABOVEDROPPED BEAM22'-0" 4'-0"CHANGE INWALL HEIGHTS22x30ATTICACCESS2'-3"RADONVENT PIPE2x66'-10 1/4" INSIDE FRAMING 0.3172 1/8" X 80"0.326068 SGDDINING18"STUDYCPT.(2) 2-65'-8 1/8"5'-8 1/8" VENT HOOD TO OUTSIDE 38.25" X 83.25"IRRIGATIONSYSTEMWOOD RAILING4'-8 1/2"HD-FLRWASTE BASKETGASTILE BACKSPLASH 1/2 OFFSET TILE BACKSPLASH 1/2 OFFSET PERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIREPLAN OPTIONSGREAT ROOM HD-FLRKITCHEN TILE BACKSPLASH - 1/2 OFFSETWASTE BASKETSTAIR RAILINGIRRIGATION SYSTEM BWP AboveBWP Above(2)9-1/2 Versa-Lam(2)7-1/4 Versa-Lam(3)14" Versa-Lam(1)14" Versa-Lam(1)14" Versa-Lam(2)14" Versa-Lam(2)9-1/2 Versa-Lam(2)11-7/8 Versa-Lam(3)18" Versa-Lam(2)7-1/4 Versa-Lam6.5666Shearwall55566PFHPFHPROVIDE 14" x 4" CONCRETESCREWS @ 16" O.C. THRU SILLPLATE INTO FOUNDATION ATTHIS WALL PORTION INADDITION TO ANCHOR BOLTSPROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY SUPPLIERHATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSTYPICAL 2x6 STUDS @ 16" O.C.FASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"PERFORATED SHEARWALL RAISEDABOVE FLOOR SYSTEM2S2FRAMING DETAILNOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.FASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSSIMPSON STHD14RJ EMBEDDEDHOLDOWN ANCHOR AT LOCATIONSSHOWN (REFER TO 3/S2 FORALTERNATIVE OPTION-TO BEUSED w/ SILL PLATE OVERHANG)BLOCK THROUGH FLOORSYSTEM AT HOLDOWNLOCATIONS AS REQ'D3.3(2)9-1/2 Versa-Lam 39'-0"3'-6"11'-4"7'-1"7'-6"2'-6"14'-7"7'-10"36'-0"4'-0" 40'-0" 11'-8"12'-6"11'-10" 2'-6"13'-2" 40'-0" 8'-6 3/4"15'-9 1/4"39'-0"20'-8"5'-6"5'-6"18'-4"6'-0"BEDRM #1CPT.2ND FLOOR PLAN1/4"=1'-0"BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR1441 SQ. FT.LIVING AREANOTE:8'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-10 1/2" U.N.O.MFD TRUSSES AT 24" O.C.GIRDER TRUSSThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C4.0XHARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AF72"W.I.C.CPT.BEDRM #3CPT.BEDRM #4CPT.BEDRM #5CPT.GAMEROOMCPT.10'-2" 5'-8" 7'-8" 3'-6" 4'-8"6'-6"6'-6"4'-9"1'-9"3'-8"7'-0"2'-6"3'-8"2'-8"2'-6"13'-2"3'-8"11'-6"9'-2"4'-8"6'-4"12'-6"2-42-42-62-42-62-62-65-04-04-04-0HD-FLRBATH #2DN16RMFD TRUSSES AT 24" O.C.34x60 FBGLSHWR72"BATH #1HD-FLR2-442x60FBGL TUB3'-9"3040 SHTEMP GL2'-7 3/4"5'-1 3/4"2'-6"3 1/2"5'-1 3/4"3050 SH3050 SH6'-10"6'-4"3050-2 SH3050 SH42" HIGH HALF WALL W/ WOOD CAP4'-7"7'-0"5-0TUB/SHWR2x6 WALL 5'-10"1'-11"1'-9"2'-9"6'-2"2-8HD-FLRLAU.WASHDRY2x6 WALL3'-11"2-46" SPLASH7'-1 3/4"1'-6"3'-4 1/2"135° 135°135°RADONVENT PIPETPH24" TOWEL BAR TPH 24" TOWEL BAR WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#1BEDRM #42W 3050 SH1BEDROOM #13050 SH1GAME ROOM3050 SH1BEDRM #33040 SH1BATH #13050 SH1BEDRM #50.310.310.310.3172 1/8" X 60 1/4"0.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 48"0.312W 3020 FX3050 SH2'-6"9'-2"3050 SH36 1/4" X 60 1/4"1BEDRM #40.310.312W 3020 FX72 1/8" X 24"6'-2 1/2"INSIDE FRAMING22x30ATTICACCESSW.S.PERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIREPLAN OPTIONSNO OPTION SELECTED(2)7-1/4 Versa-Lam(2)7-1/4 Versa-Lam-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).35Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing. FUTUREFAMILY RMUNEXCAVATEDFUTUREBEDRMThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C5.0X1/4"=1'-0"ELECTRICAL PLANUNFINISHED BASEMENTA/CWPLOW VOLTAGESYSTEM RECEPTACLESDSEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLE15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEGFISUMPWHF.D.ACHVMECH./STORAGER/I3/4BHARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AFRADONVENT PIPESSWATER SOFTRECEPTACLEPERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIREPLAN OPTIONS2ND EGRESS WINDOW WELL KIT.1/4"=1'-0"FOYERGARAGEPORCHThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6.0XHARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AFDINETTEELECTRICAL PLAN1ST FLOORDISP.DWUSBSTCHIME SWPSSSWPSGFICEILING FANROUGH-INS SS SDSDSDSSSD/CMDCSSBEDRM #11/4"=1'-0"BEDRM #3BEDRM #4W.I.C.BEDRM #5GAMEROOMBATH #2LAU.ELECTRICAL PLAN2ND FLOORS SDSSSD/CMDSS S GFIS GFI22x30ATTICACCESSFANLFANLLLRADONVENT PIPESFANBATH #1LLLLLL1/2 BSFANSGFI CS SSSMUDROOMSPRINKLERSYSTEMRECEPTACLE SSS W.I.C.SHCPGFISSSMART HOMESYSTEM RECEPTACLE22x30ATTICACCESSLLLLLLLLLLLLLLLLLRADONVENT PIPESDROUGH-INBLANK PLATELGREATROOMSS LLLLSSSTUDYS LLLLSSD VENT HOOD TO OUTSIDELLL PEND.PEND.4'-0"7'-8 1/2"7'-9"IRRIGATIONSYSTEMCD CDPERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIREPLAN OPTIONSGREAT ROOM HD-FLRKITCHEN TILE BACKSPLASH - 1/2 OFFSETWASTE BASKETSTAIR RAILINGIRRIGATION SYSTEM PLAN OPTIONSNO OPTION SELECTED These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C7.0XHARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AF1/4"=1'-0"CROSS SECTION A-A1/4"=1'-0"CROSS SECTION B-B9'-1 1/8" 10'-3 7/8"CONC WALL9'-8 1/4" 8'-1 1/2"8'-1 1/8"3/4" 250 SUBFLOOR3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORMFD TRUSS1'-4"6127 7/16"MFD TRUSS36'-0"9'-1 1/8" 10'-3 7/8"CONC WALL9'-8 1/4" 8'-1 1/2"8'-1 1/8"3/4" SUBFLOOR3/4" SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR14" MFD I-JOISTSMFD TRUSS1'-4"6127 7/16"MFD TRUSS61236'-0"4" CONC. FLOORGIRDER TRUSS4'-0"1'-4"612GARAGEFOYERGAMEROOMGREATROOM1'-4"9 7/8"6126'-0"DROPPED BEAMGREATROOMBEDRM #4FLUSH BEAMBEDRM #3BEDRM18" MFD FLOOR TRUSSES14" MFD I-JOISTS9 7/8"16" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZE1'-4"POURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE2x8 JOISTS5/4" DECKING3-2x8DROPPED BEAM6'-0"6'-8"TOP OF THRESHOLDTO TOP OF JOIST5-3/4" FROMSET ON 6" THICKPOURED CONC. WALLCONC. SIDEWALKCANT.JOISTS8"WOODPORCH18" MFD FLOOR TRUSSES7 7/16"1'-4"6122'-0"10'-5 3/8"1'-4"1'-1 7/8"1'-1 7/8"UNDERSIDEFRAME UP TOOF STAIRSPERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIRE These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C8.0XHARRISON 5465-B-3.1PC#1028: 8-24-2022-RKPC#1038,1039: 9-13-2022-RKPC#1040,1041,1042: 9-13-2022-RKPERMIT/CONSTRUCT:12-13-22-AFGARAGE SLAB LEDGE DETAIL1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL1/2"=1'-0"THE SLOPING OF THE FLOORBE PROTECTED WHEREVER4" CONC. GARAGE FLOORRIGID INSULATION MUSTCREATES AN EXPOSURE.5/8" GYP. BD.TYPICAL WALL SECTION1/2"=1'-0"9'-1 1/8"TRUSSES PER PLAN3/4" SUBFLOORVARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R C H U T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806EXT. SPRAY-ON WATERPROOFINGTREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)16x8 CONC. FTG.RUN INTO SUMP BASKETCONTINUOUS DRAIN TILEWHERE APPLICABLETREATEDSILL PLATEVERTICAL REINFORCINGAS SOIL COND. REQUIREW/ SILL SEALERMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL8" THICK, 8'-4" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.8" THICK, 42" HIGHPOURED CONC. WALL16x8 CONC. FTG.TREATED BOTTOM PLATE2x6 WALKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.POURED CONC. WALL(6" CURB, 2" INT. LEDGE)16x8 CONC. FTG.TREATED BOTTOM PLATE8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.JOISTS PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIASEALANT BY CARPENTERPRIOR TO SHEATHINGPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)W/ VAPOR BARR.5/8" GYP. BD.APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"TO EACH SIDE OF "T" FITTING IN AGGREGATE10' SECTION OF PERFORATED PIPE CONNECTED1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEFINISHED GRADEWILL VARYJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALLR-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=203.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20GYP. BD. EXCEPT 80 SF AT1/2" SAG-RESISTANTRUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTERALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER5000 PSI TESTED -OR-APPROVED ADMIXTURETHE MECHANICAL ROOMOF FOUNDATION WALL16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTURE(IF REQUIRED PER FOUNDATIONEXTEND OVER SILL PLATER-5 RIGID INSULATION(AT RIGHT AND LEFT SIDEOF HOME ONLY)SEALED AND TAPED AT TOPCALCULATIONS, R402.2.8.A)R-5 RIGID INSULATION(AT SIDE LOOKOUT FOUNDATION ONLY,NOT AT REAR LOOKOUT WALLS)R-5 RIGID INSULATION-ON INSIDETAPE & SEAL AT TOPFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEDRAINTILE AT WALKOUT WALLS(HILLCREST ONLY)W/ R-10 DRAINAGE BOARDROLL-ON WATERPROOFINGWALL EDGE, ACROSS THE TOP, ANDEXTEND FROM TOP INTERIOR6" DOWN THE EXTERIOR WALL FACE(SEE HANSON ENGINEERING)9'-1 1/8" 10'-3 7/8"9'-8 1/4" 8'-1 1/2"8'-1 1/8"39'-0"3 1/2" CONC. FLOOR6'-8"MIN HEADROOM HAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATA3/4" 250 SUBFLOOR14" MFD I-JOISTS3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL18" MFD FLOOR TRUSSES1/4"=1'-0"CROSS SECTION C-CLAU.BATH#26'-8"MIN HEADROOM LIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLE14" TO TOP OF STONE VENEER 1"=1'-0"WALL DETAILLOOKOUT FINISH2x6 TREATEDSILL PLATE1x6SILL PLATE2x4 INTERIORWALL2x_ TREATEDBLOCKING1/2" GYP. BD.1/2" GYP BD LEDGE6-1/2" CAP BOARDSHOE PERIMETERWINDOW FRAMEEXTERIOR SHEATHINGR-10 EXTERIORINSULATIONR-5 INTERIORINSULATION (IFREQ'D PER CODE)1/2"=1'-0"FLOOR DETAILR-30 BLOWN-IN3/4" SUBFLOOR6" ROUND DUCTWORKMANUFACTURED I-JOISTSR-8 INSULATION WRAPGYP. BD.SPRAY FOAM INSUL.AROUND DUCTWORKCLOSED CELL1" CLOSED CELLSPRAY FOAMINSULATIONPERMIT/CONSTRUCT PLANS17072 DRAFT HORSE BLVDLOT 19 BLOCK 7 - BROOKSHIRE FOUNDATION DETAILAT FOOTING STEP LOCATIONS1S1DescriptionDateRevisionProject Number:Date:S11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20211.0011-1-212021 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2S1WALL SECTIONLOOKOUT WALL CONDITION3S1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4S1WALL SECTIONFULL HEIGHT WALL CONDITION5S1REBAR TABLE6S1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2021©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS: F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE: SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE 1,500 PSF MINIMUMGENERAL NOTES1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3. 112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4x4'-0" HOOKS @ 24" O.C. BENT ORDRILLED AND EPOXY GROUTED3'-0"1'-0 " NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2021.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE S8 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON S11FLOOR TO SILLCONNECTION SEE S10WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2021©DescriptionDateRevisionJanuary 1, 2021Project Number:Date:1.001S21Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2146665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1S2BRICK LEDGE INFO5S2WALL SECTIONAT WINDOW WELL LOCATIONS6S2STOOP INFO7S2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2S2BLOCKING DETAILFLOOR JOIST CONDITION3S2BLOCKING DETAILFLOOR TRUSS CONDITION4S2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/S1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/S1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/S1 OR 3/S1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/S1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/S2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/S1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)FLOOR MEMBERSPACING8'-0"9'-0"10'-0"16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED,12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/A10'-0" MAX TO T.O.S. 1'-8" MAX FLASHING & WOODPROTECTION BYOTHERSFLOOR FRAMING ORBLOCKINGFLOORCONNECTIONSEE 1/S2 &2/S2C.I.P. CONCRETEWALL SEEADJACENTPLANS FORTHICKNESS &MAXIMUM WALLLENGTHSSEE FULLHEIGHT WALLSECTION 5/S1FORREINFORCINGSTOOPSLAB BYOTHERS13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL3'-0" FULL HEIGHT BASEMENTMIN FULL HEIGHT FULL HEIGHT EXAMPLE CORNEROR STRAIGHT WALLOPTIONS -TYPSTOOP AREA8" MIN C.I.P. CONCRETEWALL SEE FULL HEIGHTWALL SECTION 5/S1NOTES:1. ADD RETURN WALLS OR BUTTRESSES IN STOOP AREA AS SHOWN IF OVERALL STOOP CENTER TO CENTERWIDTH EXCEEDS DIMENSIONS SHOWN.2. STOOP WALLS REQUIRE MINIMUM 16" WIDE x 8" DEEP CONCRETE STRIP FOOTING.EXAMPLE '1'EXAMPLE '2'EXAMPLE '3'SLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.TYP * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERBACKFILL BELOWEXTERIOR STOOP SLABSWITH COMPACTEDGRANULAR MATERIALTO FROST DEPTH(4'-0" MINIMUM)NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-8" MAX 2'-6" MIN OPENING 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/S1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/S1LOOKOUTWALLSEE 3/S1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.A SECTION AD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 2 Beam by others 6' 0" 1B3 2 Beam by others 4' 0" 1UNEXCAVATEDSTAIRWAYFLOOR TRUSSESBY OTHERSPORCH FRAMINGBY OTHERSOPTIONAL EGRESSWINDOW HEADER(2) 1-3/4"X7-1/4"X6'VERSA LAM LVLB1B3B3B2B242' 0" 6' 0" 36' 0" 20' 8"18' 4"39' 0"20' 2"16' 0" 10' 0"2' 0" 24' 0" 16' 0" 10' 0"4' 0" 4' 0" ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 2B3 1 Beam by others 6' 0" 1B1B2B339' 0"16' 0" ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 1 Beam by others 8' 0" 1B3 1 Beam by others 4' 0" 1B3B2B139' 0"16' 0" UNEXCAVATED4TH STALL OPT.AT THIS AREA16' 0" 24' 0" 2' 0" 10' 0"4' 0" 20' 8"10' 0"Sheet: 1 of 4DWG: Basement BeamsFile: Plan #5466-B-GLBy: Anthony EstevezDate: 10-22-18Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5466-B-GLD.R. HORTONBASEMENT BEAMSDESIGN = L/360BASE MODELBASEMENT BEAMSWALKOUT OPTIONLOOKOUT OPTIONFOURTH STALL OPTION ProductsPlotID Net Qty ProductLength PliesJ1 2 14" BCI® 4500s-1.8 18' 0" 1J2 17 14" BCI® 4500s-1.8 16' 0" 1J3 7 14" BCI® 6000s-1.8 40' 0" 1J4 15 14" BCI® 6000s-1.8 20' 0" 1B1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2B2 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B3 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B4 4 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B5 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 22' 0" 2B6 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 20' 0" 1B7 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 18' 0" 2B8 3 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 16' 0" 3B9 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 6' 0" 1B10 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2' 0" 1B11 3 1-3/4" x 18" VERSA-LAM® 2.0 3100 SP 22' 0" 3B12 1 Beam by others 8' 0" 1B13 2 Beam by others 4' 0" 1Ca1 12 1-1/8" x 14" BC RIM BOARD OSB 12' 0" 1Pt1 1 5-1/4" x 5-1/4" VERSA-LAM® 1.8 2750 SP 12' 0" 1Pt2 1 5-1/4" x 7" VERSA-LAM® 1.8 2750 SP 12' 0" 1Pt3 2 Post by others 8' 0" 1Connector SummaryPlotID Qty Manuf ProductH1 2 Simpson HU11H2 13 Simpson IUS1.81/14H3 1 USP HDQ17112IFH4 22 USP THF23140STAIRWAYPORCH FRAMINGBY OTHERSBCI 4500s@ 19.2" OCBCI 4500s@ 19.2" OCBCI 6000s@ 19.2" OCBCI 6000s@ 19.2" OCSTART FRAMING HEREJOISTS @ 19.2" OC (U.N.O.)GARAGEOPTIONAL 6 FTWIDE WINDOW"BEAM BY OTHERS"Pt3Pt3Pt1Pt2B5B6B8B6B4B4B10B13B12B9B1B2B3B7B13B11Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1J4H3H4H4H3J3J4J2J2J1H1H1H2H320' 8"18' 4"39' 0"6' 0" 36' 0" 1' 7 3/16"1' 4"10' 0"16' 0" 10' 0"4' 0" 24' 0" 2' 0" 42' 0" GARAGE4TH STALL OPT.AT THIS AREASTAIRWAY16' 0" 10' 0"2' 0" 24' 0" 10' 0"20' 8"ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 1 Beam by others 4' 0" 1STAIRWAYSINGLETRIMMERSB1B239' 0"36' 0" 16' 0" 10' 0"Sheet: 2 of 4DWG: Upper Floor FramingFile: Plan #5465v2-B-GLBy: Anthony EstevezDate: 2-2-19Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-7-19AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5465v2-B-GLD.R. HORTONUPPER FLOOR FRAMINGDESIGN = L/480BASE MODELUPPER FLOOR FRAMINGFOURTH STALL OPTIONBED W/ BATH OPT3" PLUMBING HOLE ALLOWED WITHIN 12" OF END OF BEAM. SEE BOISE COVER SHEET FOR ADDITIONAL SPECS ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B2 1 Girder Truss by others 22' 0" 1B3 5 Beam by others 4' 0" 1Pt1 2 5-1/4" x 5-1/4" VERSA-LAM® 1.7 2650 SP 10' 0" 1STAIRWAYSINGLETRIMMERSSINGLETRIMMERSRELOCATE WINDOWHEADER AT WALK-INSHOWER OPTIONSINGLETRIMMERSSINGLETRIMMERSPt1Pt1B2B3B1B1B3B3B3B340' 0" 39' 0"36' 0" 4' 0" 18' 4"20' 8"Sheet: 3 of 4DWG: Upper Floor HeadersFile: Plan #5466-B-GLBy: Anthony EstevezDate: 10-22-18Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5466-B-GLD.R. HORTONUPPER FLOOR HEADERSDESIGN = L/360BASE MODELUPPER FLOOR HEADERSDETAIL N/A COPYRIGHT HANSON GROUP, LLC 2020©THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESSCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THE STRUCTURE AND ISEXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.DescriptionMarch 31, 2020Project Number:Date:0.144S11Sheets: of2D R Horton 20860 Kenbridge Court #100Lakeville, MN 550445465-B-GL ModelMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Ryan Mack46673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.(4-FT)(4-FT)(4-FT)(4-FT) (4-FT)(4-FT)(3-FT)(4-FT)(4-FT)BRACED WALL LINE BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINE(6-FT)(6-FT) (5-FT)(5-FT) (4-FT)(6-FT)(6-FT)(6.5-FT)(6-FT)(5-FT)(3.3-FT)(4-FT)(4-FT)BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINE(5-FT)(5-FT)(5-FT)(5-FT)(4-FT)BRACEDWALL LINEBRACED WALL LINE BRACED WALL LINE (7-FT)(7-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINE(2.5-FT)(3-FT)(6-FT)(3-FT)(3-FT)BRACED WALL LINE BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINE(3-FT)(3-FT)(2.5-FT)(3.5-FT)(4-FT)(4-FT)(4-FT)(3-FT)(6-FT)(7-FT)(6-FT)BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINEPARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONS w/ SUN ROOMTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUT FOUNDATIONS w/ SUN ROOMMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANSUN ROOM OPTION4th-STALL OPTIONUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY3S1REFERENCE PLANOPTIONALWINDOWOPTIONALWINDOWSCONSTRUCTPORTAL FRAMEAS SHOWN IN 1/S2CONSTRUCTSHEARWALL ASSHOWN IN 2/S2(5-FT)7-20-20Plan Changes7-20-201 S2FRAMING DETAILGARAGE FRONT PORTAL FRAME1NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 3/S2 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS2'-212"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)2'-212"±PROVIDE 14" x 4" CONCRETESCREWS @ 16" O.C. THRU SILLPLATE INTO FOUNDATION ATTHIS WALL PORTION INADDITION TO ANCHOR BOLTSPROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY SUPPLIERHATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSTYPICAL 2x6 STUDS @ 16" O.C.FASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"PERFORATED SHEARWALL RAISEDABOVE FLOOR SYSTEM2S2FRAMING DETAILNOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.FASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSSIMPSON STHD14RJ EMBEDDEDHOLDOWN ANCHOR AT LOCATIONSSHOWN (REFER TO 3/S2 FORALTERNATIVE OPTION-TO BEUSED w/ SILL PLATE OVERHANG)BLOCK THROUGH FLOORSYSTEM AT HOLDOWNLOCATIONS AS REQ'DALTERNATE HOLDOWNCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTIONS3S2FRAMING DETAILALTERNATE RAISED HOLDOWN12"Ø SIMPSON TITEN HD RODCOUPLER w/ 8" EMBED INTOCONCRETE (MAY OMIT &EPOXY THREADED ROD 8"DIRECTLY INTO CONCRETE)12"Ø THREADEDROD w/ NUT &WASHER ATHOLDOWN ENDSIMPSON HTT5HOLDOWN ANCHORFASTENED TODOUBLE STUDSFLOORSYSTEMCONCRETEFOUNDATIONBELOWCOPYRIGHT HANSON GROUP, LLC 2020©DescriptionMarch 31, 2020Project Number:Date:0.144S22Sheets: of2D R Horton 20860 Kenbridge Court #100Lakeville, MN 550445465 ModelAll Elevations GL & GRMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDateRevisionPrint Name:Signed: License Number:Ryan Mack3-31-2046673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota. Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 Harrison 5465 - Walkout HVAC Load Calculations for D.R. Horton Lakeville Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Wednesday, October 7, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Harrison 5465 - Walkout Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:Harrison 5465 - Walkout Designed By:Jake Ryan Project Date:10/7/2020 Project Comment: Client Name:D.R. Horton Client City:Lakeville Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Northwest Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:1,011 CFM Per Square ft.:0.281 Square ft. of Room Area:3,603 Square ft. Per Ton:1,490 Volume (ft³):30,263 Building Loads Total Heating Required Including Ventilation Air:49,641 Btuh 49.641 MBH Total Sensible Gain:22,502 Btuh 78 % Total Latent Gain:6,508 Btuh 22 % Total Cooling Required Including Ventilation Air:29,010 Btuh 2.42 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\Winston - Walkout - East - Heat Calc.rh9 Wednesday, October 7, 2020, 4:42 PM NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Alexis Flores 12/15/22 X PM