Loading...
HomeMy WebLinkAbout18144 Hinckley Ave SurveyHINCKLEY AVENUE6 Drainage and Utility Easement N00°46'19"W70.00S01°00'25"E 70.00S89°13'41"W 152.93>>>>>>>>>>>>>>>>>>>>Planned TrailBuilding Setback PROPOSED DRIVEWAY 6.9% SLOPE 1038.24 1039.42 1038. 7 1 1033. 4 41031.9310 3 6 . 1 3 N:177805.21 E:520375.92 Planned Trail355 10 524N:177790.09 E:520361.21 EX CB RIM=1036.18 25.5 29.524.8PROPOSED HOUSE PROPOSED GARAGE 735 25 711.0011.0030.0020.009.0048.00 9.0050.0044.00 12.004.00 5.546.00 12.462.00 1035.29 1036.74 103910391037 10381036103510331 0 3 1 10311 0 2 9 1 0 2 8 103 8 10 3 7 1035103510331031103010 2 9 10341036103210391037103510331036.621037.141027.281029.811 0 3 9 . 6 21039.091038.591037. 7 4 1039.621039.801039.701 0 3 9 . 8 0 1039.68 1031.56 1031.5 3 1039. 6 0 I I IIIIIIII II>>>>>>>>>>>>>>>>>>>>>>>>>>>>>I I I N89°13'41"E 152.65 75.2 1036. 2 3 1031. 7 8 1033 . 0 8 1038. 9 7 1 0 3 0 Drain Tile Cleanout 6.0011.1029.836.00 25303 L6B4 DATE REVISION SCHEDULE DESCRIPTION BY PROJECT NO. CAD FILE NAME DRAWN BY DESIGNED BY ORIGINAL ISSUE DATE CLIENT PROJECT NO. REVIEWED BY PROJECT SHEET TITLE WITHOUT PRIOR WRITTEN CONSENT. INC. AND MAY NOT BE USED, COPIED OR DUPLICATED THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,FILE LOCATION: S:\PROJECTS\25000 PROJ\25300-25399\25303 STREEFLAND PROPERTY - LENNAR - LAKEVILLE MN\25303 CIVIL-SURVEY\SURVEY PRODUCTION DRAWINGS\LOT CERTS\BLOCK 4\LOT 6\25303 L6B4.DWG 1OF CERTIFICATE OF SURVEY 1 - 21-25303 1/13/23 LAKEVILLE MINNESOTA LENNAR CORPORATION CASLANO LOT 6, BLOCK 4 RK --- MAS I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE LIC. NO.1/13/23 45817 MARK A. SCHWANZ 0 SCALE IN FEET 10 20 LEGEND Proposed Building Sanitary Line Water Line Storm Line Curb Stop Manhole Cleanout > >> I CONSTRUCTION NOTES: 1.Install rock construction entrance. 2.Install silt fence as needed for erosion. 3.Sidewalks shall drain away from house a minimum of 1%. 4.Contractor must verify driveway design. 5.Contractor must verify service elevation prior to construction. 6.Add or remove foundation ledge as required. GENERAL NOTES: 1.Grading plan by ISG last dated April 13, 2022 was used to determine proposed elevations shown hereon. 2.This survey does not purport to show improvements or encroachments, except as shown, as surveyed by ISG or under my direct supervision. 3.Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4.No specific soil investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5.If building footprint exceeds the building pad, additional earthwork and testing will be required to meet the requirements as outlined within the geotechnical report. 6.This certificate does not purport to show easements other than those shown on the recorded plat. 7.Bearings shown are based on the Final Plat. 8.Site address is 18144 Hinckley Avenue, Lakeville, MN 55044 9.House/Basement type: Snelling EH06 F3 - RIght - Walkout Building dimensions shown are based on First Floor Plan. 10.Proposed Contours are shown hereon. 11.Topographic survey was completed on January 6, 2023. BENCHMARK: Top nut fire hydrant located in the NE quadrant of Hideaway Trail and Highview Avenue Elevation = 1038.03 feet AREA TABLE: House/Garage Area = 2,283 sq. ft. Porch Area = 163 sq. ft. Driveway/Walk Area = 870 sq. ft. Total Impervious Area = 3,316 sq. ft. Lot Area = 10,695 sq.ft. Impervious Coverage = 31.0% HOUSE ELEVATIONS:Proposed/As-Built Garage Floor = 1039.8 Top of Foundation = 1040.1 Lowest Floor = 1032.1 Set Lath at Property Corner Offset Iron Existing Contour Proposed Contour Proposed Elevation Proposed Spot Elevation Existing Spot Elevation Surface Drainage Direction Proposed Tree/Shrub 982.2 982 982. 5 985.0 5 TT AA QE CO PB PS GRADING QUANTITIES (CY) Common Cut -202 Common Fill 220 Total (±)18 Note: Cut and fill quantities include building excavation, driveway, and lot grading. 1/17/23 Add Porch Dimensions RK Zoning = RS-4 FY - 20' House, 25' Garage SY - 7' Interior, 20' Corner RY - 30' SY Buffer - 30' RY Buffer - 50' The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected and accepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection. *Maintain 6" between bottom of siding and sod.*No structures in easements. EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATION *Draintile connection required. ENGINEERING REVIEWED Date:__________________01/24/2023 lritchie