HomeMy WebLinkAboutLA209886 - APPROVED - Scott Moen Solar Drawings (2)EXISTINGSNAPNRACKSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAM ATTACHMENT LAYOUTSYSTEM LABELING DETAILENPHASE RAPID SHUTDOWNINVERTER DATA SHEETSHEET INDEXPROPERTY PLANMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0PV 2.0PV 4.0PV 5.1D 6.0D 7.0D 8.0D 9.0D 10.0D 11.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:Truss 2 x 4 @ 24" O.C.COMP SHINGLEVICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record print to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.200A200A01/17/2023Property Address:Owner:Scott MoenProperty Type:Single Family ResidenceDrawn by:New@engineerinc.ioDate: HANWHA 400 WATT MODULESWITH IQ7+ MICROINVERTERS7740 204th St W, Lakeville, MN 55044CONTRACTORAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comTHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2020 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESINVERTER CERTIFICATIOND 13.0PV 3.1MONITORING DEVICED 12.0PV INSPECTION CHECKLIST ATTACHMENT DETAILPV 5.2SURGE PROTECTIOND 14.0PLACARDPV 3.2DC 22.00 KW STCAC 15.95 KW STC55 EMT type ConduitSolar Module(N) Junction BoxJB.................................................................................MSP(E) Main Service Panel200AINDEXAC.................... (N) 100A Utility AC(N) MicroinverterNOTE: Conduit in attic shallbe minimum 18 inches from roof sheatingSITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Drawn by:New@engineerinc.ioProject Name:Property Address:01/17/2023Scott Moen7740 204th St W,Lakeville, MN 55044DATE:PVS(N) 125A PV Sub Panel...........Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENT(E) Main MeterMM........................Fire Setback Line.............SECONDARY INTERCONNECTIONFMT type Conduit.............SOLAR MODULES___HANWHA 400 WattModel #Q.PEAK DUO BLK ML-G10+5555INVERTERINVERTER TYPE: Micro:___ Enphase IQ7PLUSModel # IQ7PLUS-72-2-US(240V) Dakota ElectricEQUIPMENT ELEVATIONPVC Utility ACDisconnect4'10"From roofShopSubPanelPerformanceMeter(N) Performance MeterPM.............MainMeterPB(N) PVC Box..........................Enphase<10'PVC BoxInsideOutside Total Roof Area:2844Total Module Area:121042.54% of CoverageNOTE:A 36-inchwide pathwayshall be provided to the emergencyescape and rescue opening.* Roof access is not located in areas that require placement of ground ladders over exterior wall openings (R324.6.1)CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com204th St WSolar PV Array 125- Hanwha 400 W Modules25- IQ7+ MicroinvertersPitch 26 DegOrientation:90 DegaaaaaaaaaaaaabbbbbbbbbbbbcccccccccccddddddddddeeeeeeeMSPMMPMACPVSPBJB1JB318" fire setback18" fire setbackRoof Access36" fire PathwayedJB2Solar PV Array 224 - Hanwha 400 W Modules24 - IQ7+ MicroinvertersPitch 27 DegOrientation:270 DegSolar PV Array 36 - Hanwha 400 W Modules6 - IQ7+ MicroinvertersPitch: 20 DegOrientation: 270 DegSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNENot less than an 18" clear setbackis required on both sides of ahorizontal ridge.For each roof plane with a photo-voltaic array, twopathways not less than 36" wide shall be provided fromthe lowest roof edge to ridge on the same roof plane asthe array,on an adjacent roof plane, or straddling thesame and adjacent roof planes. Not fewer than onepathway shall be provided on the street or drivewayside of the house.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode02/15/2023dpfannenstein ENPHASE Q CABLE(2) #12 AWG PV WIRE(1) #6 AWG EGCFREE IN THE AIRPV 2.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044ELECTRICAL 1-LINE DIAGRAMEnphasePV MONITORINGDEVICE125A PV SUB PANEL120/240V, 1P,3W NEMA 3R10A 2-POLENote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDesign meet National Electric Code(NEC codes)100A FUSED AC DISCONNECT,WITH 90A FUSES UTILTY AC DISCONNECT VISIBLE-OPENLOCKABLE, READILY ACCESSIBLENEMA3R 120 / 240V 1P,3WINSTALL (5)20A PV2-POLE C/B EXISTING_____ MAINPANEL120/240V,1P, 3WGEC(E) GROUNDINGELECTRODE SYSTEMSECONDARY INTERCONNECTIONREFERENCE POINT OF APPLICABILITY13.31A (6) #12 AWG THWN/THWN-2 (1) #12 AWG GND 3/4'' EMT, 7 FEETAtticWall (6) #12 AWG THWN/THWN-2 (1) #12 AWG GND 3/4'' FMT, 20 FEETSurge ProtectionMNSPD-300-ACDrawn by:New@engineerinc.io01/17/2023DATE:HANWHA 400 WATT MODULES5555ENPHASE IQ7PLUS MICROINVERTERSSYSTEM RATING AND DER POWER OUTPUTINVERTER:ENPHASE IQ8PLUS-72-2-USINVERTER MAXIMUM CONTINUOUS OUTPUT:290VASYSTEM POWER OUTPUT:ENPHASE IQ7PLUS MICROINVERTERS1 PHASE 290VAMAXIMUM OUTPUT CURRENT 1.21AAC PORT BACKFEED CURRENT 0ADC SHORT CIRCUIT CURRENT 15ADC 22.00 KW STCAC 15.95 KW STCDC 22.00 KW STCAC 15.95 KW STC Dakota Electric66.55A66.55A55x 290 =15.95Member Supplied PV production metersocket with stamped brass aluminium orstainless steel tag labeled in accordancewith NEC and AHJ requirments locatedwithin 5' of main. Inverter output wired toload side terminal of meter 1 phase 3-wire120/240VLoadLinePV Production meter socket must have leverbypass/bypassProduction meter is required based on the der sizeand program under which the application is submittedNo loads or energy storage systems shall beconnected on the DER side of the production meterNOTE: AC DISCONNECT VISIBLE AND LOCKABLE (3) #2/0 AWG AL (1) #6 AWG GND 2" SCH 8 PVC, 2 FEETMAIN METER120/240V,1P, 3W(1) #6 AWG GND(NEW)GECAdd 2nd Ground rod andtie it to the existing ground rod. (4) #12 AWG THWN/THWN-2 (1) #12 AWG GND 3/4'' EMT, 7 FEETAtticWall (4) #12 AWG THWN/THWN-2 (1) #12 AWG GND 3/4'' FMT, 20 FEET (3) #2/0 AWG AL 2" SCH 8 PVC, 2 FEETPVC Box1BRANCHCIRCUIT-E2 7.26A1BRANCHCIRCUIT-A2 15.73A1BRANCHCIRCUIT-E2 2.42AJ BOX1NEMA3R1BRANCHCIRCUIT-B2 14.52A1BRANCHCIRCUIT-C211 J BOX2NEMA3R1-PHASE MICRO-INVERTER UL17411-PHASE MICRO-INVERTER UL1741Utility1BRANCHCIRCUIT-D211 13.31ALine Side TapNON CENTER _____MAIN C/B200A(2) #12 AWG THWN/ THWN-2(1) #12 GND3/4" Offset Nipple with3/4 Ground BushingProperty Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com (3) #2/0 AWG AL 2" SCH 8 PVC, 2 FEET66.55A13200A6J BOX3NEMA3R12 PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044Drawn by:New@engineerinc.io01/17/2023DATE:66.55APV 3.1SYSTEM LABELING DETAILProduction MeterLABEL 1PV ARRAYJ BOXPV SUB-PANELACDISCONNECTMAIN SERVICEPANELMETER233331716218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTRATED MAX POWER-FONT CURRENTRATED MAX POWER-FONT VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTMAX RATED OUTPUT CURRENT OFTHE CHARGE CONTROLLER IF INSTALLEDLABEL 21***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECT21PerformanceMeter13SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSProperty Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com PLACARDPV 3.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 1 OF 2CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 2 OF 2NWESNWESDrawn by:New@engineerinc.io01/17/2023DATE:7740 204th St W,Lakeville, MN 550447740 204th St W,Lakeville, MN 55044Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comSERVICE POINT &UTILITY METERINGPV SUB PANELPVC BOXPV SYSTEM DISCONNECTFOR UTILITY OPERATIONPERFORMANCE METERSOLAR PV ARRAYSERVICE POINT &UTILITY METERINGPV SUB PANELPVC BOXPV SYSTEM DISCONNECTFOR UTILITY OPERATIONPERFORMANCE METERSOLAR PV ARRAY PROPERTY PLANLEGENDMSPMain Service Panel................PV 4.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044PV Sub PanelPVS...........................MMMain Meter............................Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by:New@engineerinc.io01/17/2023DATE: Dakota ElectricPVC BoxPB...................................Utility AC DisconnectAC.............Performance MeterPM...................Tap BoxTB......................................Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com204th St W79'-10"136'-8"79'-10"136'-8"DrivewayPROPERTY LINEMSPMMPMACPVSPB53'-3"13'-6"51'-1"16'-2"SCALE:1/16" = 1'-0" 180° 90° 270°0°SWNE ATTACHMENTLAYOUTDESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules48.5Total Module Weight (lbs)Rack Weight (lbs)MicroInverters Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)2667.5533.5130.93331.91084830.8512102.75RAIL ATTACHMENTMODULES ON ROOFTruss 2 x 4 @ 24" O.C.5555PV 5.1PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 550441 Layer of .Plywood & Building FeltSolar Module6"AttachmentMODULES ON ROOFTruss 2 x 4 @ 24" O.C.COMP SHINGLEPrior to the commencement of work, the contractor shall verify the existing roof and framingconditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction.Prior to the commencement of work, the contractor shall inspect framing for any damagesuch as water damage, cracked framing, etc. and These Plans are stamped for structuralcode compliance of the roof framing supporting the proposed PV installation reference only.These plans are not stamped for water leakage. PV modules, racking, and attachmentcomponents must follow manufacturer guidelines and requirements. Attachments to beinstalled in a staggered orientation to properly distribute loads.1.86"3.05"0.25"Ø2.24"2.58"1"0.17"3.20"1.37"0.38"0.30"1.08"2.78"1.78"1.50"1.99"1.21"R 1.12"Ø0.33"R 0.82"12345SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/BLACKBOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SSSNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SSSNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/BLACKSNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/BLACK12345DESCRIPTIONITEMQTI11111MATERIALS:DESIGN LOAD (LBS):ULTIMATE LOAD (LBS):TORQUE SPECIFICATION:CERTIFICATION:WEIGHT (LBS):DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINESS STEEL802 UP, 1333 DOWN, 357 SIDE2118 UP, 4006 DOWN, 1331 SIDE12 LB-FTUL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 25820.45OPTIONS:CLEAR/BLACKPARTS LISTSNAPNRACK, ULTRA RAIL SPEEDSEAL TM FOOTNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by:New@engineerinc.io01/17/2023DATE: Dakota ElectricProperty Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com22'-3"19'-6" PV 5.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044ATTACHMENT DETAILDrawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com INVERTERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044Drawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com ENPHASE RAPIDSHUTDOWN,COMPATIBILITY WITH PVD 7.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044Drawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com MODULEDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044Drawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com RACKINGDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044Drawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com ATTACHMENTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044Drawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 11.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044MONITORING DEVICEDATASHEETDrawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044INVERTERCERTIFICATIONDrawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044SURGE PROTECTIONDrawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com D 14.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Scott Moen7740 204th St W,Lakeville, MN 55044PV INSPECTIONCHECKLISTWolf RIver Electric Lakeville, MN 550447740 204th St WDrawn by:New@engineerinc.io01/17/2023DATE:Property Address:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com