Loading...
HomeMy WebLinkAboutLA208924 - APPROVED - Solar Bldg Permit AppRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov 12-19-2022 DE Email $201.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: (SOLAR)X X 200.00 1.00 200.00 V-B 2020 IRC-1 PUD DP 12/19/22 Rooftop Solar (15 Panels) :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ  6XEMHFW /DNVKPLQDUD\DQDQ5HVLGHQFH   +DUWOLQ$YH   /DNHYLOOH01  7R:KRP,W0D\&RQFHUQ  7KHIROORZLQJUHIHUHQFHVWKH/DNVKPLQDUD\DQDQ5HVLGHQFHLQ/DNHYLOOH01  ([LVWLQJURRIIUDPLQJ 5RRIV 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLV FDSDEOHWRVXSSRUWDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDG PRGXOHVSOXVPRXQWLQJKDUGZDUH  SVIJURXQGVQRZORDG SVIURRIPDWHULDOV SVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV  ([SRVXUH&DWHJRU\%PSKZLQG VHF   7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG  7KDQN\RX  :HVWVKRUH'HVLJQ(QJLQHHUV  ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD  6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU     -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU  '0DLQOLQH'U  :HVWILHOG0$  'DWH'HFHPEHU 5HI  Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 12/14/2022dpfannenstein Please provide a copy of the City Approved plans on site at final inspection. For each roof plane with a photo-voltaic array, two pathways not less than 36" wide shall be provided from the lowest roof edge to ridge on the same roof plane as the array,on an adjacent roof plane, or straddling the same and adjacent roof planes. Not fewer than one pathway shall be provided on the street or driveway side of the house. Not less than an 18" clear setback is required on both sides of a horizontal ridge. Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 12/19/2022dpfannenstein COMPACT PANEL Size 9 A module Current compatible with MLPE rec Alpha Pure-R SERIES Product Specifications α experience performance wp430 20.7 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT22.3%Efficiency Ref: PM-DS-12-06-Rev- B 08.22www.recgroup.com GENERAL DATA Cell type:80 half-cut REC bifacial, heterojunction cells with lead-free, gapless technology Glass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:4-part, 4 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (4 mm²) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 67 + 67 in (1.7 + 1.7 m) in accordance with EN 50618 Dimensions:68.1 x 44.0 x 1.2 in (20.77 ft2) / 1730 x 1118 x 30 mm (1.93 m2) Weight:47.4 lbs (21.5 kg) Origin:Made in Singapore Specifications subject to change without notice.Measurements in inches [mm] LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply Irradiance (W/m²)Rel. Efficiency (%)TEMPERATURE RATINGS* Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-free acc. to RoHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 MAXIMUM RATINGS Operational temperature:-40 ... +85°C System voltage:1000 V Test load (front): + 7000 Pa (146 lbs/ft2)* Test load (rear):- 4000 Pa (83.5 lbs/ft2)* Series fuse rating:25 A Reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) STC NMOTFounded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Lead-Free ELECTRICAL DATA Product Code*: RECxxxAA PURE-R Power Output - PMAX (Wp) 400 410 420 430 Watt Class Sorting - (W)0/+10 0/+10 0/+10 0/+10 Nominal Power Voltage - VMPP (V) 48.8 49.4 50.0 50.5 Nominal Power Current - IMPP (A) 8.20 8.30 8.40 8.52 Open Circuit Voltage - VOC (V) 58.9 59.2 59.4 59.7 Short Circuit Current - ISC (A) 8.73 8.81 8.89 8.97 Power Density (W/ft2)19.26 19.74 20.22 20.7 Panel Efficiency (%) 20.7 21.2 21.8 22.3 Power Output - PMAX (Wp)305 312 320 327 Nominal Power Voltage - VMPP (V) 46.0 46.6 47.1 47.6 Nominal Power Current - IMPP (A) 6.64 6.70 6.78 6.88 Open Circuit Voltage - VOC (V) 55.5 55.8 56.0 56.3 Short Circuit Current - ISC (A) 7.05 7.12 7.18 7.24 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GR GR GR GR GR 11±0.2[0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2[0.24±0.01] 1700 [67]1700 [67] Lorem ipsum 1730±2.5 [68.1±0.1] 880 [34.6]425 [16.7]1077±2.5 [42.4±0.1]22.5 [0.9] 594±3 [23.4±0.12] 1118±2.5 [44.0±0.1]17 [0.7]45 [1.8] 30 [1.2]DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:858 (26 pallets) Panels per 53 ft truck:858 (26 pallets) REC Alpha PURE-R Series Product SPECIFICATIONS Available from: The high-powered smart grid-ready Enphase IQ 7X Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase IQ System, the IQ 7X Micro integrates seamlessly with the Enphase IQ Envoy™, Enphase Q Aggregator™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7X Microinverter To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: US Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 96-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7X is required to support 96-cell modules. PRELIMINARY / US 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-01-23 INPUT DATA (DC)IQ7X-96-2-US Commonly used module pairings¹320 W - 460 W + Module compatibility 96-cell PV modules Maximum input DC voltage 80 V Peak power tracking voltage 53 V - 64 V Operating range 25 V - 80 V Min/Max start voltage 30 V / 80 V Max DC short circuit current (module Isc)10 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) Peak output power 320 VA Maximum continuous output power 315 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.31 A (240 VAC)1.51 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit 12 (240 VAC)10 (208 VAC) Overvoltage class AC port III AC port backfeed current 0 A Power factor setting 1.0 Power factor (adjustable)0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V CEC weighted efficiency 97.5 %96.5 % MECHANICAL DATA Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring optionsCompatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7X Microinverter snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience SnapNrack Umbrella Sealing Technology • Innovative Flashing Elevates Protection. New fl ashing uses a fully formed raised cone to prevent any potential water from getting into penetration. Feel secure as the fl ashing is one piece and doesn’t rely on multiple parts sealing together. • Mechanical Design Creates a Lifelong Seal. Patented Umbrella technology utilizes unique Umbrella Washer to seal lag bolt, L Foot, and fl ashing and prevent any potential roof leaks. Technology passes UL 2582 Wind Driven Rain Test without a rubber seal, however rubber gasket is included for extra peace of mind. • Single Fastener Eliminates Extra Steps. Utilize one lag bolt with Umbrella Washer to secure the entire mount assembly and fl ashing. No longer necessary to attach a base, then a fl ashing, then a mount as all are secured in one step. • Single Tool Installation. SnapNrack was the fi rst in the industry to develop a complete system that only requires a single tool. That tradition is continued as a ½” socket is still the only tool necessary to secure the mount as well as all other parts of the system. snapnrack.com Featuring New Innovative Flashing Smaller 9”x12” size allows for easier insertion under shingles Alignment markers make it easy to locate pilot holes Rounded corners make for easier insertion & eliminate corner points from folding up Note: Flashing shown in yellow for illustration purposes only. © 2018 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com snapnrack.com Ultra Rail, UR-40 Rail System Spans Wind (mph) 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 Snow (psf)0 5 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 120 System Span Key 6 ft Spans 4 ft Spans 2 ft Spans This table was prepared in compliance with applicable engineering codes and standards. Values are based on the following: • ASCE 7-10 • Chapter 30 Wind Loads & Chapter 7 Snow Loads • Roof Slope: 7 - 27 deg • Roof Height: 0 - 30 ft • Exposure: B • Roof Zone: 1 • Module Orientation: Portrait • Module Type: 60 Cell Modules • Roof Type: Comp Industry Leading Spans for a Light Rail Solution Visit SnapNrack.com for detailed span tables and certifi cations. Certifi cations SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 for wind-driven rain. Raised Cone Flashing Single Lag Secures Mount to Roof Pre-assembled Ultra Rail L Foot & Clamp Pre-assembled Ultra Rail