LA208649 - APPROVED - Solar Bldg Permit App - 20940 Goodhue Way
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov DE Email 12-2-2022 $201.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: X X (SOLAR) 200.00 1.00 201.00 V-B 2020 IRC-1 RST-2 DP 12/2/22 Rooftop Solar (31 Panels) :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW *DUORFN5HVLGHQFH *RRGKXH:D\ /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH*DUORFN5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 5RRIV 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLV FDSDEOHWRVXSSRUWDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD 6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU '0DLQOLQH'U :HVWILHOG0$ 'DWH1RYHPEHU 5HI Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 12/02/2022dpfannenstein Provide copy of city approved plans on the job site for the inspector MSPUMCBACDPVMACD~173.92'~102.72'~107.25'~36.05'~104.72'9'-9"52'-8"41'-4"47'-5"SHEET NUMBERPV-1 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-4991194-6METER NUMBER : 17845745PREMISE NUMBER : 304496649CASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR11/12/2022INITIAL RELEASESHEET NAMEPROJECT NAMERICH GARLOCK 20940 GOODHUE WAY, LAKEVILLE, MN 55044 USA APN# 221674005070 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (612) 207-8347SITE PLAN WITHROOF PLANSITE PLAN WITH ROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:A. ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC.SHALL NOT BE INSTALLED WITHIN 3’ OF THEGAS METERS’ SUPPLY OR DEMAND PIPING.INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ7A-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45AOPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METER(E) UTILITY METER(N) ENPHASE IQ COMBINER BOX 3(E)200A MAIN SERVICE PANEL WITH(E)200A MAIN BREAKER (INSIDE)(31) REC SOLAR REC400AA PURE BLACK (400W) MODULES(31)ENPHASE IQ7A-72-2-US MICRO-INVERTERS(02) BRANCHES OF 11 MODULES &(01) BRANCH OF 09 MODULES CONNECTED IN PARALLEL(N) XCEL ENERGY PRODUCTIONMETER 120/240V, 200A WITHBYPASS 1-PHASE, 3-WIRENOTES:1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN.FINAL LOCATION MAY CHANGE.2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENTNOT DRAWN TO SCALE.3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION4. AC DISCONNECT AND PRODUCTION METER IN READILY ACCESSIBLELOCATION WITHIN 10' OF MAIN READILY SERVICE METER/BI-DIRECTIONALMETER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITYAC DISCONNECT, PV PRODUCTION METER, & BI-DIRECTIONAL METER.5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 ANDPOSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC705-10, 690-17, & 690-64 (b)(5).LABELS LOCATED ON PV PRODUCTION METER,BI- DIRECTIONAL METER, AC DISCONNECT (S),INVERTER(S), AND APPROPRIATE LABELS ON MAINELECTRIC SERVICE. ALL LABELS ARE PERMANENT,WEATHERPROOF, AND DURABLE THERE ARE NOCLEARANCE ISSUES DUE TO OVERHEAD POWERLINES.OPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METERROOF #1(31)REC SOLAR REC400AA PUREBLACK (400W) MODULESEXISTINGDRIVEWAYTWO- STORYHOUSE(E) TREES (TYP.)10'MAX(N) SERVICE AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLE(N) UTILITY AC DISCONNECTVISIBLE-OPEN TYPE, LOCKABLE,READILY ACCESSIBLEDISTANCESSOLAR PANELS - INVERTERS: 5'INVERTERS - IQ COMBINER PANEL: 25'IQ COMBINER PANEL - UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT - PV PRODUCTION METER: 2'PV PRODUCTION METER - SERVICE AC DISCONNECT: 2' SERVICE AC DISCONNECT - MAIN ELECTRIC SERVICE: 2' MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 2'PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEGOODHUE WAY210TH ST W (~270') MSPUMCBACDPVMACDSHEET NUMBERPV-2 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-4991194-6METER NUMBER : 17845745PREMISE NUMBER : 304496649CASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR11/12/2022INITIAL RELEASESHEET NAMEPROJECT NAMERICH GARLOCK 20940 GOODHUE WAY, LAKEVILLE, MN 55044 USA APN# 221674005070 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (612) 207-8347ROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"171.7"40"PHOTOVOLTAIC MODULESREC SOLAR REC400AA PURE BLACK (400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 31 MODULESMODULE TYPE = REC SOLAR REC400AA PURE BLACK(400W) MODULESMODULE WEIGHT = 45 LBS / 20.5 KG.MODULE DIMENSIONS = 71.7"X 40" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSFNOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAYR324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:3377.03 sqftAREA OF ARRAYS:71.7"X 40" ( PANEL DIMENSIONS)71.7"X 40" = 19.92 sqft (PER PANEL)19.92 sqftpanel X 31 panels = 617.42 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(617.42 sqft / 3377.03 sqft)(100)= 18.28%∴THE PANELS USE 18.28% OFTHE TOTAL ROOF AREABILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL20SNAP N RACK UR-40 RAILSPLICE10RAIL SPLICEMID CLAMP48MODULE MID CLAMPEND CLAMP28MODULE END CLAMPATTACHMENT77SNAP N RACK SPEEDSEALDECKFOOTGROUNDING LUG07GROUNDING LUGLEGENDUM- UTILITY METERMSP- MAIN SERVICE PANELACD- AC DISCONNECTCB- COMBINER BOX 3- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- TRUSSESPVM- PRODUCTION METER(N) XCEL ENERGY PRODUCTION METER120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE(N) SNAP N RACK UR-40 RAIL(E) 2"X4" TRUSSES @ 24" O.C. (TYP.)(N) ENPHASE IQ COMBINER BOX 3(E) 200A MAIN SERVICE PANEL WITH(E) 200A MAIN BREAKER (INSIDE)(E) COMP SHINGLE ROOF (TYP.)(E) UTILITY METERROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#139°180°2"X4"24" O.C.ROOF #1(31) REC SOLAR REC400AA PUREBLACK (400W) MODULES(N) SERVICE FUSED AC DISCONNECTVISIBLE-OPEN TYPE, LOCKABLE, READILYACCESSIBLE(N) UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLEACD- AC DISCONNECTGOODHUE WAYFRONT YARD REAR YARD(N) (77) SNAP N RACK SPEEDSEALDECKFOOT ATTACHMENTSSPACED AT 48" O.C.18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY 18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY 36" FIRE PATHWAY10' MAXConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/02/2022dpfannensteinNo less than 18 inch clearsetback is required on bothsides of a horizontal ridgeFor each roof plane with a photo-voltaicarray, a 36 inch wide pathway shall beprovided from lowest roof edge to ridge onthe same roof plane, on adjacent roof planes.One shall be on street/driveway side. SHEET NUMBERPV-3 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-4991194-6METER NUMBER : 17845745PREMISE NUMBER : 304496649CASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR11/12/2022INITIAL RELEASESHEET NAMEPROJECT NAMERICH GARLOCK 20940 GOODHUE WAY, LAKEVILLE, MN 55044 USA APN# 221674005070 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (612) 207-8347ATTACHMENTDETAIL SNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOFMOUNTING ONTO WOOD DECKINGREFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLERAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"NUMBER ON THIS DRAWING(X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBEDFULLY INTO WOOD DECKREFER TO SNAPNRACK INSTALLATION MANUAL FOR 5HARDWARE TORQUE SPECIFICATIONS16"RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT.SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THESLOPE OF THE ROOFFOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACKDETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENTDETAIL, ULTRA RAIL LEVELING SPACER"SNAPNRACK, SPEEDSEALDECKFOOT BASE, SEALINGSNAPNRACK, UR MOUNTTHRUSNAPNRACK, UR MOUNTTAPPEDEXPLODEDSNAPNRACK, ULTRA RAILTOPCOMP SHINGLE ROOFING, TYP.3.860COIL SPRING FOR 3SERRATED FLANGE, S.S.8"BOLT, S.S. (OPTIONAL)5.200MODULE HEIGHT, MAX:UR-40 = 438"COMP SHINGLE ROOFING, TYP.ROOF DECKING, TYP.SCREW HEIGHTOFF ROOF:916"112"158"UR-40 RAILFOR USE WITH SNAPNRACK ULTRA SERIES RAILSMINIMUM DECK THICKNESS:PLYWOOD:15/32"ATTACHMENT DETAILSECTION VIEWOSB: 716"(4X) #14 FULLY THREADEDWOOD SCREW. S.S. MUST EMBEDFULLY INTO WOOD DECKINSTALLATION OVERVIEWROOF DECKING, TYP. 25'-0" 25'-6" 35'-2" 38'-3"SHEET NUMBERPV-4 SHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-4991194-6METER NUMBER : 17845745PREMISE NUMBER : 304496649CASE NUMBER : N/AREVDATEDESCRIPTIONVERSIONUR11/12/2022INITIAL RELEASESHEET NAMEPROJECT NAMERICH GARLOCK 20940 GOODHUE WAY, LAKEVILLE, MN 55044 USA APN# 221674005070 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLE CUSTOMER PHONE NUMBER: (612) 207-8347ELEVATION PLANELEVATION PLANSCALE: NTS1SOUTH SIDE OF HOUSE(N) PV MODULESWINDOW (TYP.) rec Alphα® pure Black Series Product Specifications α experience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 385 390 395 400 405 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14 Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3 Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9 Power Output - PMAX (Wp)293 297 301 305 309 Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 132 half-cut REC heterojunction cells with lead-free, gapless technology 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm) Weight:45 lbs (20.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:-40 ... +185°F (-40 ... +85°C) Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq ft)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending) ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 The high-powered smart grid-ready Enphase IQ 7A Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7A Microinverter To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Efficient and Reliable • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility.2. CEC peak power tracking voltage range is 38 V to 43 V.3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility.5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2019-11-07 INPUT (DC)IQ7A-72-2-US Commonly used module pairings¹295 W–460 W + Module compatibility 60-cell, 66-cell, and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range²18 V–58 V Min/Max start voltage 30 V / 58 V Max DC short circuit current (module Isc)³15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT (AC)@ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211–264 V 208 V / 183–229 V Maximum continuous output current 1.45 A (240 VAC)1.39 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47–68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit5 11 (240 VAC)11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0 %96.5% MECHANICAL Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type: DC (IQ7A-72-2-US)MC4 Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection — No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring optionsCompatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7A Microinverter MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINLESS STEEL, FOAM SEE STRUCTURAL ENGINEERING SEE STRUCTURAL ENGINEERING 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 0.65 OPTIONS: SILVER / BLACK DRAWN BY: mwatkinsSNAPNRACK, ULTRA RAIL SPEEDSEAL™ DECKFOOT REVISION: A 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.242-02173, 242-02174 PART NUMBER(S): DESCRIPTION: PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS11 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS12 SNAPNRACK, SPEEDSEAL DECKFOOT BASE, SEALING, SILVER / BLACK13 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR14 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR15 1 2 4 3 5 NOTE: CAN BE DECK-MOUNTED OR RAFTER-MOUNTED ALL DIMENSIONS IN INCHES DRAWN BY: mwatkinsSNAPNRACK, ULTRA RAIL SPEEDSEAL™ DECKFOOT REVISION: A 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.242-02173, 242-02174 PART NUMBER(S): DESCRIPTION: 1.00 1.00 1.67 1.00SLOT R.50 TYP 3.05 3.865.20 .93 .93 .93 2.781.78 4.98 3.64 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³