Loading...
HomeMy WebLinkAbout18120 Hinckley Ave SurveyU E U N:178015.59 E:520369.62 HINCKLEY AVENUE3 I I I I I I >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>GGGGGGN00°46'19"W70.00S01°00'25"E70.00N89°13'41"E 151.79 S89°13'41"W 152.079.709.7010.3010.3030.004.0010.756.00 Planned TrailDrain Tile Cleanout 103 1 . 5 0 1025. 7 2 10 2 3 . 5 2 1030.77N:178000.10 E:520358.55 1031. 2 0 10 2 9 . 0 1 1029 . 8 2 1030. 5 1 1031. 3 3 Only offsets were staked - construction materials on lot Building Setback Drainage and Utility Easement5 35 10 5772522 28PROPOSED HOUSE PROPOSED DRIVEWAY 7.2% SLOPE PROPOSED GARAGE 78.3 25.5 PORCHPlanned Walk10311031102410231022 10221023102410251025102710321031 10 3 1 1 0 3 0 1 0 2 9 102510231 0 2 2 102510301032 103310311031 10311025102610271028Planned Storm Structure23.114.00 1025.851033.131 0 3 3 . 3 1 103 3 . 4 0 1033.331031.0 4 10 3 1 . 7 51030.34 1025. 2 9 1030. 6 6 1030 . 6 5 1 0 2 3 . 2 0SWAL E 1024.13SWALE1024.35 H.P. SWALE 1025.34 1024.801025.30 1025.171025.65 1024.891 0 2 4 . 1 9 10 3 1 . 9 2 1 03 2 . 3 2 1026.891026.851 0 2 9 . 1 6 1 0 2 9 . 1 1 1024. 8 0 18120 Hinckley Ave 1025102410241026 1034 1030102721.54 10.0026.4620.0012.466.00 8.00 17.5434.00 9.5040.006.00 25303 L3B4 DATE REVISION SCHEDULE DESCRIPTION BY PROJECT NO. CAD FILE NAME DRAWN BY DESIGNED BY ORIGINAL ISSUE DATE CLIENT PROJECT NO. REVIEWED BY PROJECT SHEET TITLE WITHOUT PRIOR WRITTEN CONSENT. INC. AND MAY NOT BE USED, COPIED OR DUPLICATED THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,FILE LOCATION: S:\PROJECTS\25000 PROJ\25300-25399\25303 STREEFLAND PROPERTY - LENNAR - LAKEVILLE MN\25303 CIVIL-SURVEY\SURVEY PRODUCTION DRAWINGS\LOT CERTS\BLOCK 4\LOT 3\25303 L3B4.DWG 1OF CERTIFICATE OF SURVEY 1 - 21-25303 2/8/23 LAKEVILLE MINNESOTA JW - MAS LENNAR CORPORATION CASLANO LOT 3, BLOCK 4 CONSTRUCTION NOTES: 1.Install rock construction entrance. 2.Install silt fence as needed for erosion. 3.Sidewalks shall drain away from house a minimum of 1%. 4.Contractor must verify driveway design. 5.Contractor must verify service elevation prior to construction. 6.Add or remove foundation ledge as required. GENERAL NOTES: 1.Grading plan by ISG last dated May 9, 2022 was used to determine proposed elevations shown hereon. 2.This survey does not purport to show improvements or encroachments, except as shown, as surveyed by ISG or under my direct supervision. 3.Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4.No specific soil investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5.If building footprint exceeds the building pad, additional earthwork and testing will be required to meet the requirements as outlined within the geotechnical report. 6.This certificate does not purport to show easements other than those shown on the recorded plat. 7.Bearings shown are based on the Final Plat. 8.Site address is 18120 Hinckley Avenue, Lakeville, MN 55044 9.House/Basement type: Sinclair EH01 K3 - Right - Walkout 10.Building dimensions shown are based on First Floor Plan. 11.Proposed Contours are shown hereon. 12.Topographic survey was completed on January 19, 2023. BENCHMARK: Top nut fire hydrant located in the NE quadrant of Hideaway Trail and Highview Avenue. Elevation = 1038.03 feet AREA TABLE: House/Garage Area =1,864 sq. ft. Porch Area = 164 sq. ft. Driveway/Walk Area = 791 sq. ft. Total Impervious Area = 2,819 sq. ft. Lot Area = 10,635 sq.ft. Impervious Coverage = 26.5% HOUSE ELEVATIONS:Proposed/As-Built Garage Floor = 1033.4 Top of Foundation = 1033.7 Lowest Floor = 1025.7 Lowest Opening = 1025.7 I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE LIC. NO.2/8/23 45817 MARK A, SCHWANZ LEGEND Proposed Building Sanitary Line Water Line Storm Line Underground Gas Line Curb Stop Fire Hydrant Water Valve Manhole/Catch Basin Transformer > >> I Set Lath at Property Corner Offset Iron Existing Contour Proposed Contour Proposed Elevation Proposed Spot Elevation Existing Spot Elevation Surface Drainage Direction Proposed Tree/Shrub Utility Marker Utility Pedestal 982.2 982 982 . 5 985.0 5 GI GS PA PB PS QB G U E GRADING QUANTITIES (CY) Common Cut -105 Common Fill 510 Total (±)405 Note: Cut and fill quantities include building excavation, driveway, and lot grading. 0 SCALE IN FEET 10 20 Zoning = RS-4 FY - 20' House, 25' Garage SY - 7' Interior, 20' Corner RY - 30' SY Buffer - 30' RY Buffer - 50' The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection. *Maintain 6" between bottom of siding and sod. *No structures in easements. EROSION CONTROLMUST BE INSTALLED BEFORE EXCAVATION *Draintile connection required. ENGINEERING REVIEWED Date:__________________02/24/2023 asobottka