Loading...
HomeMy WebLinkAboutLA211242 - 19921 Harrisburg Way - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND *ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERwritten consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cBERRES RIDGE MODEL #11#23-006SMA1102023STONE COTTAGE CONSTRUCTION, INC. FRONT ELEVATION 1/4" = 1'-0" 7127125126"WOOD PORCH9' POURED FOUNDATION9' CEILING @ FIRST FLOORTOTAL2nd FLR.1st FLR.1,149 SQ. FT.1,314 SQ. FT.2,463 SQ. FT.ANDERSEN 100 SERIESFRONT ONLYGRIDS IN WDWS.STONE AS SHOWNFRONT & SIDESWINDOWS9" BOXEDCEDAR BEAM4" TRIMFRONT ONLY4" VINYL SIDINGSIDES & REARLP PANEL SIDINGFRONT ONLY12x12 BOXED CEDARCOL. ON 16x16x54STONE BASE161216127124'-6"SSALL SIDESALUM. SOFFIT & FASCIATOTALBSM'T816 SQ. FT.3,279 SQ. FT.8" TRIM4" TRIM4" TRIM1'-6"SSSS4" TRIM FRONT DOOR TRIM Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode04/13/2023dmathews Planco MN, Inc.C#23-006SMA2102023 REAR ELEVATION 1/8" = 1'-0" SIDINGVINYL VINYLCORNERS1'-3"DECKLEDGER1'-158"101271271216127121'-0" LEFT ELEVATION 1/8" = 1'-0" 712SIDINGVINYL SIDINGVINYL VINYLCORNERS1'-0"WRAPSTONE 10"161210121'-9"1'-9"712WDW. WELLEGRESSLPPANEL RIGHT ELEVATION 1/8" = 1'-0" 3'-4"STAIRLANDINGSIDINGVINYL VINYLCORNERSLPPANELLPPANELSecure door closed until deck isconstructed with a separate permit. Planco MN, Inc.C#23-006SMA3102023 BASEMENT PLAN 1/4" = 1'-0" UP16 R(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG. UNEXCAVATED WHFURNF.D.92%SUMP4834 FAMILY ROOM *CARPET BEDROOM #5 *CARPET MECH/STORAGE *UNFINISHED2-9 1/2" LSL2'-8"2'-6"2'-4"4'-0"2-11 7/8" LSL FLUSHTREATED 4x6 CURB2x6 - 16" O.C.20x8 FTG.TREATED 4x6 CURB2x6 - 16" O.C.20x8 FTG.TREATED 4x4 CURB2x4 - 16" O.C.20x8 FTG.TREATED 2x8 16" O.C.TRD. 3-2x8 FLUSHTRD. 3-2x8 FLUSH62'-0"15'-0"15'-0"14'-0"49'-0"19'-6"42'-6"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 6'-0"6" 1'-0"44'-0"24'-6"24'-6"2'-0"22'-6"11'-6"13'-0"4'-6"5'-10"9'-8"3'-8"3'-8" 14'-0"8'-0"9"9'-6"9"5'-10"10'-6"14'-6"24'-0"18'-0"2" LEDGE9' POURED FOUNDATIONWALLEDGEWALLEDGE5'-0"48"11 7/8" I JST. 19.2" O.C. 11 7/8" LSL 19.2" O.C. 11 7/8" LSL 19.2" O.C.2-2x10TREATED 4x4 CURB2x4 - 16" O.C.20x8 FTG.20'-8" 11 7/8" I JST. 19.2" O.C.10"2'-6"10'-6"5'-10"2'-6"11 7/8" I JST. 16" O.C. 18'-10"1/2 WALL2-11 7/8" LSL FLUSH42x48x12 CONC.PAD FTG. W/2-#4 REBAR EACH WAY4'-0"RADONVENTTREATED 4x6 CURB2x6 - 16" O.C.20x8 FTG.”),1,6+('64)76" CANT.11'-0"20'-0"11'-6"7'-11" 3'-9" 3'-7" 2-2x10 5/0x4/0 SL 4'-0"1 PIECE FIB.F*VINYL7'-4" 6'-8"UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Planco MN, Inc.C#23-006SMA4102023 FIRST FLOOR PLAN 1/4" = 1'-0" 1,149 SQ. FT.9' CEILING @ FIRST FLOOR62'-0"15'-0"15'-0"14'-0"PED 49'-0"REF'GUP17 RDN16 R16" S.B.x8'-0"2'-6"9/0x5/0 SL3-9 1/2" LSL3-9 1/2" LSL 6'-0" P.D.2'-4"2'-4"2'-4"2'-8"FIREDOORPANTRY*VINYL16" SH'S2'-8" C.O. FOYER *WOOD*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM OFFICE *CARPET*4" CONC. FLOOR GARAGE WOOD PORCH 19'-6"42'-6"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 5'-6"1'-0"1'-0"44'-0"8'-0"7'-0"7'-6"7'-6"8'-0"6'-0"2'-0"4'-0"2-2x102/0x2/0 AWN24'-6"11'-6"13'-0"6'-2"5'-4"24'-0"18'-0"6'-0"8'-4"9'-8"5'-0"7'-0"*VINYL*VINYL W.I.C. *VINYL5'-3"6'-6"5'-3"2'-0"3'-6"8'-0" CAB.3'-6"7'-1"3'-6"2'-10"6'-6"3'-8"3'-8"4'-6"6'-8"10"WALLEDGEWALLEDGE2x62x6RAIL2'-6"4'-10"7'-2" 11'-0"3'-6516"GYP. BD.5'-6"4'-3"9"9'-6"9"FSD14'-0"8'-0"CHASE30" SLIP-IN RANGE W/ HOODVENT1'-0"2/6x5/0-2 SH2-9 1/2" LSL20" FLR.TRUSS 19.2" O.C. 2'-10"2'-10" 2/6x2/0 FX 2-2x10 2/6x2/0 FX 2-2x10 20" FLR.TRUSS 19.2" O.C. GIRDER GIRDER 3-11 7/8" LSL FLUSH2-11 7/8" LSL FLUSH 24" CANT.TRUSSES 24" O.C. GIRDER F.T.2-2x1020" FLR.TRUSS 19.2" O.C.6'-0"2-9 1/2" LSL FLUSH2-2x103-7 1/4" LSL3-7 1/4" LSLRADONVENT*2x6 WALLSTRUSSES24" O.C. 4'-9"2-9 1/2" LSL7/6x5/0 SL2'-8"GASF.P.2x61'-0"2'-6"2'-6"12x12 BOXED CEDARCOL. ON 16x16x42STONE BASEREF'GRECESS1'-212"4'-2"RAISE 6"OFF FLOOROVEN/MICRO3"9x8 OVH. DR.11'-0"20'-0"11'-6"5'-10"5'-2"10'-0"10'-0"5'-4"6'-2"9x8 OVH. DR.16x8 OVH. DR.24'-6"2'-0"22'-6"3'-0"BUILT-INSBUILT-INS 4'-3"TRUSSES24" O.C.GIRDER TRUSSES 24" O.C.1'-0"5'-0"2-11 7/8" LSL2-11 7/8" LSL3-11 7/8" LVL2-2x10BWPsAbove993332.57103384.5PFHPFHPFHHold-down Planco MN, Inc.C#23-006SMA5102023 SECOND FLOOR PLAN 1/4" = 1'-0" 1,314 SQ. FT.DN17 R5'-0" TUB & SHOWER 1 PIECE FIB.2'-6"66"2'-4"2'-6"2'-6"5'-0"2'-8"5'-0"2'-4" C.O.2'-4"2-2x107/6x5/0 SL*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET BEDROOM #4 *CARPET W.I.C. *CARPET*VINYL*VINYL5/0x6/0 FIXED 2-2x10 40" OFF LANDING TEMP 44'-0"15'-0"15'-0"14'-0"12'-10"2'-2"7'-6"7'-6"43'-0" 1'-0"38'-0"4'-0" 11'-0"2'-8"7'-4"5'-8"11'-4"WALLEDGEWALLEDGE8'-138"9'-5 5 16"3'-6"18'-0" 13'-1"4'-11"44'-0"26'-0"18'-0"12'-0"14'-0"6'-0"6'-0"7'-0"7'-0"4'-6"5'-10"5'-11"3'-8"3'-8" 15'-6"F3-2x106/0x4/6 SL2/6x4/6CSMT6'-7"6'-3"SD/COSDSDSDSDACCESS ATTIC 2'-6"1/2 WALLW/ WD. CAP2'-0"2'-0"10'-1"3'-9"5'-4"GIRDERTRUSSES 24" O.C. TRUSSES 24" O.C.TRUSSES24" O.C.GIRDERTRUSSES24" O.C.6'-5"2x62x6RADONVENTLIN.2'-0"5'-0"11'-2"2'-10"2'-0"7'-9"GIRDER3'-0"3'-9"4'-2 5 16"TRUSSES24" O.C.3'-8"3'-8"WD11'-35 16"1/2 WALLW/ WD. CAP7'-1"2'-4"PKT.7'-9" 2'-0"2'-0"*BOX VAULT6'-8"27"LT2/6x4/6FX2-2x102/6x4/6CSMT3"3"3"2/6x4/6-2 CSMT2-2x102'-4"112"7'-6"6'-6"12'-0" 3'-8"8'-4"12'-0"6'-0"FF2-2x105/0x4/0 FX TEMP4'-1"3'-5"1'-11"4'-7"2-2x102/6x4/0 SHPKT.FREESTANDINGTUB6454*C.T.2'-8"2'-6"*C.T.*C.T.TRUSSES 24" O.C.24"LIN.3'-4"2x2TRUSSES 24" O.C.*11'-8"x10'4"*10'-6"x12'-4"3'-0"-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.103333333243 Planco MN, Inc.C#23-006SMA6102023 CROSS SECTION 3/8" = 1'-0" 17 RISERS 9'-11 8"3/4" T & G FLOORCURBTREATED 4x416 RISERS  “11 7/8" I JST. @ 19.2" O.C. CURB2X6- 16" O.C.TREATED 4x63 1/2" CONC. FLOOR2X4- 16" O.C.CURB2X6- 16" O.C.TREATED 4x68'-11 8"5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.2x6R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-49 INSUL.11'-8"2x6- 16" O.C.1/2" GYP. BD.R-21 INSUL.1/2" GYP. BD.2x6- 16" O.C.3/4" T & G FLOOR2x42x6VBR-21 INSUL.W/ V.B.5/8" GYP. BD.VB2'-0"R-20 SPRAY FOAM20" FLOOR TRUSSES @ 19.2" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDDRAIN TILE R-20 SPRAY FOAMR-20 SPRAY FOAMENERGY HEEL6'-6"(DESIGNED BY MFR)TRUSSES @ 24" O.C.DECKING2x8 JTS. @ 16" O.C.6x6 POST35'-0"3'-0"GIRDERR-20 SPRAY FOAM3-7 1/4" LSL1251'-0"6'-0"50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTIC1/2" SHTG.15# FELTSHINGLES1'-9"712R-30 INSUL.MIN.PROOFINGWATERR-10 W/ <2.6 ACHINSUL.24x24 PADFOOTING12x16 PIERFOOTING3-2x8GRADEVENTEDSOFFITFASCIAALUM. ALUM.TRT. 6x6 POSTSIDINGSHEATHING7/16" OSBHOUSE WRAP9" BOXEDCEDAR BEAM20X820X820X8FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSWATER PROOFINGGRADEDRAIN TILE 11 7/8" LSL @ 19.2" O.C. 5/8" GYP. BD.FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS7 7 16"6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS4- 2x12 STRINGERSTAIR NOTES:10" ROUGH CUT TREADSR-10 W/ <2.6 ACHINSUL.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATED75 8"ALUM.ALUM. FASCIASOFFITVENTED1'-9"FLASHINGAPPLY STONE TO12x12x54 TREATEDPLYWOOD BOX12x12 BOXEDCOLUMN2'-4 9 16" 11 3 16" BEDROOM #3 BEDROOM #2 GREAT ROOM OFFICE Planco MN, Inc.C#23-006SMA7102023 CROSS SECTION 3/8" = 1'-0" 9'-11 8"3/4" T & G FLOORCURBTREATED 4x6 “11 7/8" LSL @ 19.2" O.C. 3 1/2" CONC. FLOOR20X82X6- 16" O.C.8'-11 8"5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-49 INSUL.2x6- 16" O.C.1/2" GYP. BD.R-21 INSUL.1/2" GYP. BD.2x6- 16" O.C.3/4" T & G FLOORVBR-21 INSUL.W/ V.B.5/8" GYP. BD.VB4'-0"R-20 SPRAY FOAM20" FLOOR TRUSSES @ 19.2" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDPROOFINGWATERR-10 W/ <2.6 ACHINSUL.DRAIN TILE R-20 SPRAY FOAMR-20 SPRAY FOAMENERGY HEEL(DESIGNED BY MFR)TRUSSES @ 24" O.C.7'-6"DECKING2x8 JTS. @ 16" O.C.24x24 PADFOOTING12x16 PIERFOOTING3-2x8GRADE3-7 1/4" LSL7'-0"6x6 POST35'-0"4'-0"GIRDER4'-0"GIRDERCURBTREATED 4x416X82X4- 16" O.C.2-11 7/8" LSL3-11 7/8" LSLR-20 SPRAY FOAM50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTIC1/2" SHTG.15# FELTSHINGLES712R-30 INSUL.MIN.SIDINGSHEATHING7/16" OSBHOUSE WRAPSIDINGSHEATHING7/16" OSBHOUSE WRAP1'-0"15'-6"BOX VAULT @MASTER BDRM2'-0"2'-0"FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS11 7/8" I JST. @ 16" O.C. 5/8" GYP. BD.2X6- 16" O.C.APPLY STONE TO12x12x42 TREATEDPLYWOOD BOX2'-4 9 16"125FLASHING1'-0"VENTEDSOFFITFASCIAALUM. ALUM.9" BOXEDCEDAR BEAMTRT. 6x6 POST12x12 BOXEDCOLUMNWATER PROOFINGGRADEDRAIN TILE FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSR-10 W/ <2.6 ACHINSUL.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATED MASTER BEDROOM BEDROOM #4 DINING FOYER Planco MN, Inc.C#23-006SMA81020234" CONC. FLOOR GARAGE 16X8GRADEPOURED WALL2X6- 16" O.C.SLOPE TO DOORS CROSS SECTION 3/8" = 1'-0" 9'-118"3/4" T & G FLOOR “11 7/8" LSL @ 19.2" O.C. 3 1/2" CONC. FLOOR8'-118"5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-49 INSUL.2x6- 16" O.C.1/2" GYP. BD.R-21 INSUL.1/2" GYP. BD.2x6- 16" O.C.3/4" T & G FLOORVBR-21 INSUL.W/ V.B.5/8" GYP. BD.VBR-20 SPRAY FOAMR-20 SPRAY FOAM20" FLOOR TRUSSES @ 19.2" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDPROOFINGWATERR-10 W/ <2.6 ACHINSUL.DRAIN TILE R-20 SPRAY FOAMR-20 SPRAY FOAM(DESIGNED BY MFR)TRUSSES @ 24" O.C.10'-31 4"(DESIGNED BY MFR)TRUSSES @ 24" O.C.12'-0"24'-0"2'-7"ENERGY HEEL50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICVENTEDSOFFITALUM.ALUM. FASCIA1/2" SHTG.15# FELTSHINGLES1'-9"7127'-818"1/2" GYP. BD.SIDINGSHEATHING7/16" OSBHOUSE WRAPSIDINGSHEATHING7/16" OSBHOUSE WRAPFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSWATER PROOFINGGRADEDRAIN TILE R-10 W/ <2.6 ACHINSUL.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATED2'-0"1'-0"1'-2"5'-71116"GARAGEWALL5127125'-71116"PORCHBEAM6316" Planco MN, Inc.C#23-006SMA9102023 GARAGE 9'-11 8"3/4" T & G FLOOR CROSS SECTION 3/8" = 1'-0"  “11 7/8" LSL @ 19.2" O.C. 3 1/2" CONC. FLOORPROOFINGWATER5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.PER CODEWALL W/ REBAR8'-4" POUREDSILL PLATE1-2x6 TREATED4" CONC. FLOORSLOPE TO DRAIN1/2" GYP. BD.R-10 W/ <2.6 ACHINSUL.20" FLOOR TRUSSES @ 19.2" O.C.R-20 SPRAY FOAMGIRDER6'-0"5/8" GYP. BD.R-20 SPRAY FOAMR-30 INSUL.MIN.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.CLEATFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSDRAIN TILE GIRDER(DESIGNED BY MFR)TRUSSES @ 24" O.C.161250% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICGIRDER20'-0"5'-0" Planco MN, Inc.C#23-006SMA1010202320'-0"1'-634"1'-6"VENTEDSOFFITALUM.ALUM. FASCIA GARAGE (DESIGNED BY MFR)TRUSSES @ 24" O.C.16121/2" SHTG.15# FELTSHINGLES50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTIC1'-63 4"1'-6"VENTEDSOFFITALUM.ALUM. FASCIA CROSS SECTION 3/8" = 1'-0" ROOF PLAN 1/8" = 1'-0" 12571216121612712712712161216127121012101271216/121'-9"1'-158"1'-9"1'-0"1'-6"1'-0"1'-2"1'-0"1'-9"1'-6"1'-3"14'-0"9516"1'-6"VENTEDSOFFITALUM.ALUM. FASCIA BEDROOM #4 (DESIGNED BY MFR)TRUSSES @ 24" O.C.16121/2" SHTG.15# FELTSHINGLES50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTIC9516"1'-6"VENTEDSOFFITALUM.ALUM. FASCIA CROSS SECTION 3/8" = 1'-0" FLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FAN BASEMENT PLAN 1/4" = 1'-0" UP16 R(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG. UNEXCAVATED WHFURNF.D.92%SUMP4834 FAMILY ROOM *CARPET BEDROOM #5 *CARPET MECH/STORAGE *UNFINISHED2-9 1/2" LSL2'-8"2'-6"2'-4"4'-0"2-11 7/8" LSL FLUSHTREATED 4x6 CURB2x6 - 16" O.C.20x8 FTG.TREATED 4x6 CURB2x6 - 16" O.C.20x8 FTG.TREATED 4x4 CURB2x4 - 16" O.C.20x8 FTG.TREATED 2x8 16" O.C.TRD. 3-2x8 FLUSHTRD. 3-2x8 FLUSH62'-0"15'-0"15'-0"14'-0"49'-0"19'-6"42'-6"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 6'-0"6" 1'-0"44'-0"24'-6"24'-6"2'-0"22'-6"11'-6"13'-0"4'-6"5'-10"9'-8"3'-8"3'-8" 14'-0"8'-0"9"9'-6"9"5'-10"10'-6"14'-6"24'-0"18'-0"2" LEDGEWALLEDGEWALLEDGE5'-0"48"11 7/8" I JST. 19.2" O.C. 11 7/8" LSL 19.2" O.C. 11 7/8" LSL 19.2" O.C.2-2x10TREATED 4x4 CURB2x4 - 16" O.C.20x8 FTG.20'-8" 11 7/8" I JST. 19.2" O.C.10"2'-6"10'-6"5'-10"2'-6"11 7/8" I JST. 16" O.C. 18'-10"1/2 WALL2-11 7/8" LSL FLUSH42x48x12 CONC.PAD FTG. W/2-#4 REBAR EACH WAY4'-0"RADONVENTTREATED 4x6 CURB2x6 - 16" O.C.20x8 FTG.6" CANT.11'-0"20'-0"11'-6"6'-3"3'-9"5'-3" 2-2x10 5/0x4/0 SL 4'-0"1 PIECE FIB.F*VINYLFULL FOUNDATION - NO WOOD FRAMEPRESCRIPTIVE BRACING REQUIRED ON THIS LEVEL FIRST FLOOR PLAN 62'-0"15'-0"15'-0"14'-0"PED 49'-0"REF'GUP17 RDN16 R16" S.B.x8'-0"2'-6"9/0x5/0 SL3-9 1/2" LSL2-9 1/2" LSL 6'-0" P.D.2'-4"2'-4"2'-4"2'-8"FIREDOORPANTRY*VINYL16" SH'S2'-8" C.O. FOYER *WOOD*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM OFFICE *CARPET*4" CONC. FLOOR GARAGE WOOD PORCH 19'-6"42'-6"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 5'-6"1'-0"1'-0"44'-0"8'-0"7'-0"7'-6"7'-6"8'-0"6'-0"2'-0"4'-0"2-2x102/0x2/0 AWN24'-6"11'-6"13'-0"6'-2"5'-4"24'-0"18'-0"6'-0"8'-4"9'-8"5'-0"7'-0"*VINYL*VINYL W.I.C. *VINYL5'-3"6'-6"5'-3"2'-0"3'-6"8'-0" CAB.3'-6"7'-1"3'-6"2'-10"6'-6"3'-8"3'-8"4'-6"6'-8"10"WALLEDGEWALLEDGE2x62x6RAIL2'-6"4'-10"7'-2" 11'-0"3'-6516"GYP. BD.5'-6"4'-3"9"9'-6"9"FSD14'-0"8'-0"CHASE30" SLIP-IN RANGE W/ HOODVENT1'-0"2/6x5/0-2 SH2-2x1020" FLR.TRUSS 19.2" O.C. 2'-10"2'-10" 2/6x2/0 FX 2-2x10 2/6x2/0 FX 2-2x10 20" FLR.TRUSS 19.2" O.C. GIRDER GIRDER 2-11 7/8" LSL FLUSH2-11 7/8" LSL FLUSH 24" CANT.TRUSSES 24" O.C. GIRDER F.T.2-2x1020" FLR.TRUSS 19.2" O.C.6'-0"2-9 1/2" LSL FLUSH2-9 1/2" LSL FLUSH2-7 1/4" LSL2-7 1/4" LSLRADONVENT*2x6 WALLSTRUSSES24" O.C. 4'-9"3-2x107/6x5/0 SL2'-8"GASF.P.2x61'-0"2'-6"2'-6"12x12 BOXED CEDARCOL. ON 16x16x42STONE BASEREF'GRECESS1'-212"4'-2"RAISE 6"OFF FLOOROVEN/MICRO3"9x8 OVH. DR.11'-0"20'-0"11'-6"5'-10"5'-2"10'-0"10'-0"5'-4"6'-2"9x8 OVH. DR.16x8 OVH. DR.24'-6"2'-0"22'-6"3'-0"BUILT-INSBUILT-INS 4'-3"TRUSSES24" O.C.GIRDER TRUSSES 24" O.C.1'-2"5'-0"3'3'SEE DETAIL 1/PF-140'31'31'BWL 1BWL 2BWL 3BWL 4BWL 5SEE DETAIL 2/PF-13'3'3'2'-6"10'7'9'9'8'4'4'-6" SECOND FLOOR PLAN DN17 R5'-0" TUB & SHOWER 1 PIECE FIB.2'-6"66"2'-4"2'-6"2'-6"5'-0"2'-8"5'-0"2'-4" C.O.2'-4"2-2x107/6x5/0 SL*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET BEDROOM #4 *CARPET W.I.C. *CARPET*VINYL*VINYL5/0x6/0 FIXED 2-2x10 40" OFF LANDING TEMP 44'-0"15'-0"15'-0"14'-0"12'-10"2'-2"7'-6"7'-6"43'-0" 1'-0"38'-0"4'-0" 11'-0"2'-8"7'-4"5'-8"11'-4"WALLEDGEWALLEDGE8'-138"9'-5 5 16"3'-6"18'-0" 13'-1"4'-11"44'-0"26'-0"18'-0"12'-0"14'-0"6'-0"6'-0"7'-0"7'-0"4'-6"5'-10"5'-11"3'-8"3'-8" 15'-6"F3-2x106/0x4/6 SL2/6x4/6CSMT6'-7"6'-3"SD/COSDSDSDSDACCESS ATTIC 2'-6"1/2 WALLW/ WD. CAP2'-0"2'-0"10'-1"3'-9"5'-4"GIRDERTRUSSES 24" O.C. TRUSSES 24" O.C.TRUSSES24" O.C.GIRDERTRUSSES24" O.C.6'-5"2x62x6RADONVENTLIN.2'-0"5'-0"11'-2"2'-10"2'-0"7'-9"GIRDER3'-0"3'-9"4'-2 5 16"TRUSSES24" O.C.3'-8"3'-8"WD11'-3 5 16"1/2 WALLW/ WD. CAP7'-1"2'-4"PKT.7'-9" 2'-0"2'-0"*BOX VAULT6'-8"27"LT2/6x4/6FX2-2x102/6x4/6CSMT3"3"3"2/6x4/6-2 CSMT2-2x102'-4"112"7'-6"6'-6"12'-0"3'-8"8'-4"12'-0"6'-0"FF2-2x105/0x4/0 FX TEMP4'-1"3'-5"1'-11"4'-7"2-2x102/6x4/0 SHPKT.FREESTANDINGTUB6454*C.T.2'-8"2'-6"*C.T.*C.T.TRUSSES 24" O.C.24"LIN.3'-4"2x2TRUSSES 24" O.C.*11'-8"x10'4"*10'-6"x12'-4"3'-0"BWL 6BWL 7BWL 8BWL 944'40'3'3'3'4'3'2'3'3'3'3'10' Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 115Exposure C BWL 1 2 3 4 5 6 7 8 9Spacing - ft 40 40 31 31 31 40 40 44 44Level 2 2 2 2 2 1 1 1 1Length req'd- ft 11.5 11.5 9.3 9.3 9.3 6 6 6.6 6.6per Table R602.10.3(1) Adjustments: Exposure 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3Eave to ridge Height 1.12 1.12 1.12 1.12 1.12 1.24 1.24 1.24 1.24Wall Height 0.95 0.95 0.95 0.95 0.95 0.9 0.9 0.9 0.9# of BWL 1 1 1.3 1.3 1.3 1 1 1 14" Gyp WB w.block joints0.7 1 1 1 1 1 1 1 1Adjusted Length 11.1 15.9 16.7 16.7 16.7 8.7 8.7 9.6 9.6Berres Ridge Model #1119921 Harrisburg Way, Lakeville, MNSheet Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 27,469Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not ApplicableAttic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 53,407 Heating Gain Cooling Load Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville19921 Harrisburg Way BC636874 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 34,049 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Stone Cottage HVAC Load Calculations for Stone Cottage 19921 Harrisburg Way Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Thursday, March 30, 2023 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Thursday, March 30, 2023 Client Name:Stone Cottage Client Address:19921 Harrisburg Way Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Northeast Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,271 CFM Per Square ft.:0.352 Square ft. of Room Area:3,612 Square ft. Per Ton:1,273 Volume (ft³) of Cond. Space:32,508 Building Loads Total Heating Required Including Ventilation Air:53,407 Btuh 53.407 MBH Total Sensible Gain:27,469 Btuh 81 % Total Latent Gain:6,580 Btuh 19 % Total Cooling Required Including Ventilation Air:34,049 Btuh 2.84 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19921 HARRISBURG LAKEVILLE 03302023.rhv Thursday, March 30, 2023, 8:29 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 3 Miscellaneous Report System 1 Whole House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29.27 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:No No Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:650 ft./min 450 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:8 in.6 in. Maximum Height:10 in.6 in. Outside Air Data Winter Summer Infiltration Specified:0.250 AC/hr 0.130 AC/hr 92 CFM 48 CFM Infiltration Actual:0.250 AC/hr 0.130 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 22,167 X 22,167 5,542 Cu.ft./hr 2,882 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:92 CFM 48 CFM Total Building Ventilation:140 CFM 70 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.31 = (0.68 X 0.970 X 29.27 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.250 AC/hr (92 CFM), Construction: Unknown Summer Infiltration Specified:0.130 AC/hr (48 CFM), Construction: Unknown C:\ ...\19921 HARRISBURG LAKEVILLE 03302023.rhv Thursday, March 30, 2023, 8:29 AM NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 3/31/23 X PM