Loading...
HomeMy WebLinkAboutItem 05 Relive Health Elite Wellness 1 City of Lakeville Planning Department M EMORANDUM To : Planning Commission From: Frank Dempsey, AICP, Associate Planner Date: April 14, 2023 Subject: Packet Material for the April 20, 2023 Planning Commission Meeting Agenda Item: Jacob Berg (Relive Health Elite Wellness) Conditional Use Permit Action Deadline: June 3, 2023 INTRODUCTION Jacob Berg, representing Relive Health Elite Wellness, has submitted a conditional use permit application and plans proposing to establish an indoor commercial recreation facility in the I-1, Light Industrial District located in a multi-tenant industrial building in Interstate South Logistics Park located at 9583 – 217th Street. Section 11-86-7.D allows commercial recreation facilities in the I-1 District subject to approval of a conditional use permit. The facility is proposed as a wellness and fitness gym. Outdoor GreatRoom, an outdoor yard equipment manufacturer, and Dalsin Industries, a metal fabricator, occupy the remaining spaces in the multiple tenant building. EXHIBITS A. Location and Zoning Map B. Aerial Photo Map C. Application Narrative and Floor Plan (2 pages) D. Property Site Plan (2 Pages) 2 STAFF ANALYSIS Zoning. The subject property is zoned I-1, Light Industrial District. The multiple tenant building on the property is 158,000 square feet in area. The proposed wellness/fitness facility will include a first floor and mezzanine level totaling 21,000 square feet. The space will include gym equipment, locker rooms, administrative offices, meeting rooms, health and nutritional guidance, accessory sales of related health products, and spa services including massage therapy and classroom space. City Code requires that massage therapy practitioners be licensed by the City. Section 11-86-7.D of the Zoning Ordinance allows commercial recreation facilities in the I-1 District subject to compliance with five listed criteria. The five criteria and my analysis of each are as follows: 1. The architectural appearance and function plan of the building and the site shall be designed with a high standard of architectural and aesthetic compatibility with surrounding properties. Building materials, orientation, colors, height, roof design, lighting, signage and site landscaping shall be designed to complement the surrounding industrial properties and demonstrate potential industrial reuse. All sides of the principal and accessory structures are to have essentially the same or a coordinated, harmonious exterior finish treatment. The existing exterior building appearance and interior functional plan will not be altered with the proposed commercial recreation facility. The masonry exterior of the multiple tenant building meets the requirements of the I-1 District. 2. A commercial recreational use shall not be located within a shared tenancy building containing a use classified as an "H" occupancy as defined by Minnesota state building code, as may be amended. According to the building owner and City of Lakeville Building Inspection records, there are no H (Hazardous) occupancy tenants in the subject building. No future H classified tenant may occupy the subject building while the commercial recreation use occupies the same principal building. 3. In multiple occupancy buildings, a material safety data sheet (MSDS) shall be required identifying all materials stored or used in the operation of the tenant businesses. Any change in building tenants shall require that the MSDS be updated and provided to all other tenants in the multi-tenant building. 3 A recommended stipulation will require that the property owner or future tenants in the multiple tenant building provide material safety data sheets to determine there are no hazardous (H occupancies) and no hazardous materials present that could endanger use of the proposed commercial recreation space as proposed by Relieve Health, or any future commercial recreation facility tenant occupying the same space subject to this conditional use permit. 4. A commercial recreational use in a shared tenancy building shall have its own exterior entrance and exit. An individual separate entrance is the only entrance into the tenant space proposed by this conditional use permit. 5. The site must be accessed via a collector street. Vehicular access points shall create a minimum of conflict with through traffic movement, shall comply with chapter 19 of this title and shall be subject to the approval of the city engineer. 217th Street, the primary access to the proposed facility, is classified as a minor collector road. The property also abuts 215th Street (CSAH 70) to the north which is classified as a principal arterial road. Parking is provided on the north side of the building and accessed via a private shared driveway with the building to the south via 217th Street. The private driveway is shared with semi-truck traffic accessing the warehouse loading docks in the subject building and the building to the south. The entire building requires 200 parking spaces of which 165 spaces are striped. There are 35 deferred parking spaces along the south side of the property. The parking deferment was proposed and approved allowing building occupancy flexibility for various tenants undetermined at the time the site plan was approved. Business days and hours for the facility are proposed to be daily, 5:00 am to 11:00 pm. Findings of Fact are attached for your review and consideration. RECOMMENDATION Planning Department staff recommends approval of the conditional use permit for the Relive Health Elite Wellness indoor commercial recreation use in the I-1 District at 9583 - 217th Street, subject to the following stipulations: 4 1. No H (Hazardous) Occupancy tenants are allowed in the multiple tenant industrial building as long as the commercial recreation use is a tenant in the same building. 2. The current tenant and any future tenants of the building being jointly occupied by this commercial recreation use shall submit Material Data Safety Sheets (MSDS) to the City including and periodic updates at they might occur. EOF = 988.8' PER C801 DETAIL RIPRAP SWALE PER DETAIL 6 ON C801 (TYP.) RIPRAP SWALE PER DETAIL 6 ON C801 (TYP. 13)DRIVE INDRIVE IN25 TRAILER PARKING (FUTURE)25 90 75 FUTURE AND DEFERRED FUTURE AND DEFERRED22 13 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO 9' KO NORTH BUILDING ±157,844 SF F.F.E=±996.5'NO PARKINGNO PARKINGNO PARKINGNO PARKING70 (215TH STREET WEST)DODD BOULEVARDS0°00'00"E 978.2013 TRAILER PARKING (FUTURE) 13 RETENTION POND NWL: 987.0' 10-YR HWL: ±988.97' 100-YR HWL: ±990.90' INFILTRATION AREA BTM ELEV: 987.0' 10-YR HWL: ±988.97' TYP R 3 0 ' R10'R1 5 'R20' R3' R10' R 6 5 ' TYP. R4 7 . 5 7 ' R 3 ' TYP. 9'20'9'24'20'20'20'25' 16'7'16'7'5'60'58'30'212'750'92.46'92.33'15' 30'15'5' 10' 24'50'24'5'140 . 9 4 ' 24' 26' 14.9'113.75'20.89' 10' 10. 1 3 ' 46.27' 15' 3'40'20' 15' 5.51'5'5'5'5'15' 6'R3'R 1 5 ' 13' 11' TYP. TYP.50.56'STAIRS - SEE SHEET C-301 FOR GRADING INFORMATION - SEE ARCHITECTURAL/STRUCTURAL PLANS FOR STAIR DETAILS STAIRS - SEE SHEET C-301 FOR GRADING INFORMATION - SEE ARCHITECTURAL/STRUCTURAL PLANS FOR STAIR DETAILS R3 ' 8'20'COORDINATE GAS AND ELECTRICAL SERVICE WITH OWNER PRIOR TO PATIO CONSTRUCTION 8'26'C-101 SITE PLAN NORTH DWN BY: ISSUE DATE: PROJECT NO.:Z:\227703887\drafting\21-503 ISLP North Building\5_DESIGN\1_CAD\3 PLANSHEETS\C-103 SITE PLAN NORTH.dwg 9/3/2021 KOITA, YACOUBADESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.: SHEET TITLE:9/3/2021 4:09:33 PMCLIENT:PROJECT TITLE:CHK'D BY:APP'D BY: CERTIFICATION: 7500 OLSON MEMORIAL HWY SUITE 300 GOLDEN VALLEY, MN 55427 PHONE: 763-252-6800 FAX: 952-831-1268 WWW.WENCK.COM INTERSTATE LOGISTIC PARKNORTH BUILDINGCITY OF LAKEVILLEDAKOTA COUNTY, MINNESOTA5024-20-500 YMK PWS JTW 09/03/2021 4006/18/2018CITY SUBMITAL109/04/2018CONSTRUCTION DOCUMENTS205/05/2021SITE REVISION CD SET3407/21/202109/03/2021CITY COMMENT REVISIONSTENANT IMPROVEMENTSDate: I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. License #:48677 09/04/18 STANDARD PARKING COUNT 193 STALLS PARKING SUMMARY REQUIRED PROPOSED TOTAL PARKING COUNT ACCESSIBLE PARKING COUNT 6 STALLS 199 STALLS 200 STALLS 158 STALLS 7 STALLS OFFICE ±14,206 SF BUILDING USE 90% AREA #OF STALLS TOTAL WAREHOUSE ±127,854 SF ±142,060 SF 199 STALLS 71 STALLS 128 STALLS CODE REQ. 1 STALL/200 SF 1 STALL/1000 SF PARKING ANALYSIS *NOTE:INCLUDES FUTURE AND DEFERRED STALLS. CODE ALLOWS UP TO 50% REQUIRED STALLS TO BE DEFERRED. CALCULATIONS BASED OFF GFS-10% PER CITY CODE 11-19-7A. DEFERRED PARKING COUNT 50% MAX 35 STALLS WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. GOPHER STATE ONE CALL TWIN CITY AREA: 651-454-0002 TOLL FREE 1-800-252-1166 CALL BEFORE YOU DIG KEYNOTE LEGEND CONCRETE SIDEWALK. SEE DETAIL GENERAL LOCATION OF MONUMENT SIGN BY OTHERS. EXACT LOCATION AND DETAIL TO BE DETERMINED. SITE LIGHTING. REF PHOTOMETRIC PLANS. REF ARCH / MEP PLANS FOR ELECTRICAL ROUTING. MAX POLE HEIGHT 25' FLUSH CURB IN THIS AREA FOR ADA ACCESS. SEE C301 FOR DETAIL ACCESSIBLE PARKING SIGN ACCESSIBLE VAN PARKING SIGN. ACCESSIBLE AISLE STRIPING - AREA STRIPED WITH 4" SBSL @ 45° 2' O.C. 4" WHITE PAVEMENT STRIPING - DASHED OR SOLID PER PLAN DOOR LOCATION / STRUCTURAL STOOP. REFERENCE ARCH / STRUCTURAL PLANS PAVEMENT TYPE. SEE LEGEND PAVEMENT SETBACK BUILDING SETBACK BUILDING DOCK DOOR. REFERENCE ARCH / STRUCTURAL PLANS FOR DETAIL AND EXACT LOCATION. BUILDING DRIVE IN DOOR AT FFE. REFERENCE ARCH / STRUCTURAL PLANS FOR DETAIL AND EXACT LOCATION. 3' WIDE CURB CUT WITH RIPRAP TO NWL. SEE C301 FOR DETAILED GRADING. KNOCK OUT FOR FUTURE DOCK. REFERENCE ARCH / STRUCTURAL PLANS FOR DETAIL AND EXACT LOCATION 20' PUBLIC SANITARY SEWER EASEMENT PROPERTY LINE SITE LEGEND SETBACK LINE EASEMENT LINE PROPOSED B612 CURB AND GUTTER STANDARD DUTY BITUMINOUS PAVEMENTP1 P3 HEAVY DUTY CONCRETE PAVEMENT STANDARD DUTY CONCRETE SIDEWALK PAVEMENT. A LANDSCAPED AREA. REFERENCE LANDSCAPE PLANS #PROPOSED PARKING COUNT P2 HEAVY DUTY BITUMINOUS PAVEMENT PROPOSED INTEGRAL CURB GREENSPACE SUMMARY IMPERVIOUS AREA (INCL. BLDG) PROPOSED PERVIOUS AREA SETBACK SUMMARY BUILDING NORTH (FRONT YARD) 30' PARKING SOUTH (REAR YARD) WEST (SIDE YARD) 40'15' 15' 5' 5'10' 30' EAST (SIDE YARD) IMPERVIOUS AREA (INCL. BLDG) FUTURE PERVIOUS AREA FUTURE ±335,817 SF (±7.71 AC) ±146,959 SF (±3.37 AC) IMPERVIOUS COVERAGE IMPERVIOUS COVERAGE FUTURE 69.6% SITE ANALYSIS TABLE LOT 1, BLOCK 1, INTERSTATE SOUTH LOGISTICS PARK EXISTING ZONING I-1 LIGHT INDUSTRIAL LOT AREA PROPOSED ZONING I-1 LIGHT INDUSTRIAL BUILDING FOOTPRINT ±157,844 GSF OFFICE AREA ±15,784 GSF WAREHOUSE AREA ±142,060 GSF ±482,776 SF (±11.08 AC) ±320,665 SF (±7.36 AC) ±162,111 SF (±3.72 AC) 66.4% SITE NOTES 1.ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY / COUNTY REGULATIONS AND CODES, AND O.S.H.A STANDARDS. 2.CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS, AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 3.ALL DISTURBED AREAS ARE TO RECEIVE SIX INCHES OF TOPSOIL, SEED, MULCH, AND WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED. 4.ALL DIMENSIONS AND RADII ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 5.SITE BOUNDARY, TOPOGRAPHY, UTILITY, AND ROAD INFORMATION TAKEN FROM A TOPOGRAPHICAL SURVEY BY STANTEC CONSULTING SERVICES. 6.TOTAL LAND AREA IS ±11.08 ACRES. 7.CONTRACTOR SHALL REFERENCE ARCH/MEP PLANS FOR SITE LIGHTING AND ELECTRICAL PLANS. 8.REFERENCE ARCHITECTURAL PLANS FOR TRASH ENCLOSURE DETAILS AND DESIGN. 4 4 1 CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA RELIVE HEALTH ELITE WELLNESS CONDITIONAL USE PERMIT On April 20, 2023 the Lakeville Planning Commission met at their regularly scheduled meeting to consider the request of the Jacob Berg (Relive Health Elite Wellness) for a conditional use permit to allow a commercial recreation use in the I-1, Light Industrial District located at 9583 – 217th Street. The Planning Commission conducted a public hearing on the proposed conditional use permit preceded by published and mailed notice. The applicant was present and the Planning Commission heard testimony from all interested persons wishing to speak. FINDINGS OF FACT 1. The property is located in Comprehensive Planning District No. 6, which guides the property for Industrial use. 2. The property is zoned I-1, Light Industrial District. 3. The legal description of the property is: Lot 1, Block 1, Interstate South Logistics Park 4. Section 11-4-3E of the City of Lakeville Zoning Ordinance provides that a conditional use permit may not be issued unless certain criteria are satisfied. The criteria and our findings regarding them are: a) The proposed action has been considered in relation to the specific policies and provisions of and has been found to be consistent with the Official City Comprehensive Plan. Finding: The proposed commercial recreation use is consistent with the policies and provisions of Planning District 6 of the 2040 Comprehensive Land Use Plan. b) The proposed use is or will be compatible with future land uses of the area. Finding: The proposed commercial recreation use is compatible with surrounding industrial uses provided compliance with the stipulations of the conditional use permit. 2 c) The proposed use conforms with all performance standards contained in the Zoning Ordinance and the City Code. Finding: The proposed commercial recreation use conforms to the performance standards set forth in the Zoning Ordinance given compliance with the stipulations of the conditional use permit. d) The proposed use can be accommodated with existing public services and will not overburden the City’s service capacity. Finding: The proposed commercial recreation use will not overburden the City’s sanitary sewer and water systems and can be served with existing public services. e) Traffic generation by the proposed use is within capabilities of streets serving the property. Finding: Traffic generation by the commercial recreation use can be accommodated with the existing streets serving the property. 5. The planning report dated April 14, 2023 prepared by Associate Planner Frank Dempsey is incorporated herein. RECOMMENDATION The Planning Commission recommends the City Council approve the conditional use permit conditioned upon compliance with the planning report prepared by Associate Planner Frank Dempsey dated April 14, 2023. Dated: April 20, 2023 LAKEVILLE PLANNING COMMISSION BY: ________________________________ Jenna Majorowicz Chair