HomeMy WebLinkAboutLA210237-APPROVED - TOMSHEA_Plans_V0_12222022SS63a52abddbb37COVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEM16163 LOGARTO LN, LAKEVILLE, MN 55044 USAREVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-0 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSYSTEM SUMMARY:ROOF TYPE: - COMP SHINGLENUMBER OF LAYERS: - 01ROOF FRAME: - 2"X6" RAFTERS @24" O.C.STORY: - TWO STORYSNOW LOAD : - 50 PSFWIND SPEED :- 115 MPHWIND EXPOSURE:- BEXPOSURE CATEGORY:- IICO-ORDINATES:- 44.715097, -93.260277DESIGN CRITERIA:2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0PV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 ELECTRICAL LINE DIAGRAMPV-5 PLACARDS & WARNING LABELSPV-6ADDITIONAL NOTESPV-7+EQUIPMENT SPEC SHEETSSHEET INDEX(N) 35 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES(N) 35 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS(N) JUNCTION BOX(E) 150A MAIN SERVICE PANEL WITH (E) 150A MAIN BREAKER(N) AC DISCONNECT 60A FUSED,WITH 60A FUSES, 240 VAC(N) PRODUCTION METER(N) ENPHASE IQ COMBINER BOX 4GOVERNING CODES:PROJECT SITEARRAY LOCATIONSGENERAL NOTES·ALL ELECTRICAL WORK SHALL BE PERFORMED BY A QUALIFIED LICENSEDELECTRICIAN AND/OR APPRENTICES WORKING UNDER THE DIRECTSUPERVISION OF THE LICENSED CONTRACTOR.·ALL WORK CARRIED OUT SHALL COMPLY WITH THE SPECIFICATIONS,APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS.·PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL NOTIFYTHE ENGINEER OF AN DISCREPANCIES NOTED AMONG SITE CONDITIONS,MANUFACTURER RECOMMENDATIONS, OR AUTHORITY HAVING JURISDICTION. IFTHE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESEDRAWINGS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF RECORD AWRITTEN "RFI"(REQUEST FOR INFORMATION) PROPOSING AN ALTERNATIVE ORSEEKING CLARIFICATION.·THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OFPLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THEPREMISES AT ALL TIMES.·UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHINGMATERIALS, EQUIPMENT, ACCESSORIES, AND LABOR NECESSARY TO COMPLETEALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.·ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCEWITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTORSHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS,ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLICAUTHORITY REGARDING THE PERFORMANCE OF WORK.·THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY STATED OTHERWISE.·CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA,ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BEAFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TOALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION.·FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FORALL ROOF WORK.·WHEN INSTALLING IN FIRE RATED AREAS, SEAL ALL PENETRATIONS WITH ULLISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALLKEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS.·CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. ALL DEBRIS ANDOTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN ALAWFUL MANNER.·THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS,CURBS, LANDSCAPING AND STRUCTURES NOT PART OF THE SCOPE OF WORKAS IDENTIFIED IN THESE PLANS.·THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FORTHE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION.·DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY AREEXPOSED TO LIGHT, CONTRACTOR SHALL DISABLE THE ARRAY DURINGINSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, ORCOVERING ARRAY WITH AN OPAQUE COVER ACCORDING TO MANUFACTURER'SINSTRUCTION.·CONSTRUCTION LOADING ON THE ROOF, SUCH AS MATERIAL STAGED ON THEROOF, SHALL BE LIMITED TO 20 PSF. CONCENTRATED LOADING SHALL BEAVOIDED TO PREVENT LOCALIZED DAMAGE TO THE ROOF.35 MODULES-ROOF MOUNTED - 14.00 kWDC, 10.15 kWAC2020 NATIONAL ELECTRICAL CODE (NEC)2020 MINNESOTA STATE BUILDING CODE (MSBS)2018 INTERNATIONAL EXISTING BUILDING CODES ANDAMENDMENTS2018 INTERNATIONAL RESIDENTIAL CODE (IRC)2018 INTERNATIONAL FUEL GAS CODE (IFGC)2018 INTERNATIONAL MECHANICAL CODE (IMC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)HASTINGS CITY CODEProfessional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538123-DEC-2022
~133.03'~77.08'~131.10'~76.14'10'-5"32'-7"42'-2"8'-6"ACDMSPUMCBPVMJBACDMSPUMCBPVMJBSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.NOTE:A.ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALLNOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’SUPPLY OR DEMAND PIPING.(N) 3/4" OR GREATEREMT CONDUIT RUN(7/8" ABOVE ROOF)ROOF ACCESS POINTJUNCTION BOXJBMSPMAIN SERVICE PANELENPHASE IQ COMBINER 4CBCONDUITGATEPROPERTY LINEFENCETREELEGENDAC DISCONNECTACDUMUTILITY METERLOGARTO LNEXISTINGDRIVEWAYTWO- STORYHOUSEPRODUCTION METERPVM(E) STRUCTURE(TYP.)Professional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538123-DEC-2022
2'-5"10'-5"1'-2"3'-9"21'-0"1'-6"1'-9"18'-8"1'-6"1'-5"37'-5"4'-3"ACDMSPUMCBPVMJBREVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"174.0"41.1"PHOTOVOLTAIC MODULESHANWHA Q CELLS Q.PEAK DUO BLKML-G10+ (400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 35 MODULESMODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULESMODULE WEIGHT = 48.5 LBS / 22.0 KG.MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SFUNIT WEIGHT OF ARRAY = 2.30 PSFARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#118380.18622.0661.12#217359.05552.4365.00ROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHRAFTERSSIZERAFTERSSPACING#130°164°2"x6"24" O.C.#230°254°2"x6"24" O.C.NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS&TRUSSES (OR SEAM) LOCATIONS MAY VARY.INSTALL PER MANUFACTURER(S) INSTALLATIONGUIDELINES AND ENGINEERED SPANS FORATTACHMENTS.LEGENDMSP- MAIN SERVICE PANEL- JUNCTION BOXJBCB- COMBINER BOX 4- VENT, ATTIC FAN(ROOF OBSTRUCTION)- RAFTERS- CONDUIT- CHIMNEY· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL26NXT HORIZON RAIL 168" DARKSPLICE18NXT HORIZON RAIL SPLICEUNIVERSAL CLAMP82NXT HORIZON COMBO CLAMP -DARKACCESSORIES24NXT HORIZON RL & CLMP CAP KITATTACHMENT97UNIRAC FLASHLOC ATTACHMENTMLPE & GROUNDING41NXT HORIZON MLPE & LUG CLAMP(N) (97) UNIRAC FLASHLOCATTACHMENTS SPACED AT 48" O.C.R324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:3015.30 sqftAREA OF ARRAYS:74.0"X 41.1" ( PANEL DIMENSIONS)74.0"X 41.1" = 21.12 sqft (PER PANEL)21.12 sqftpanel X 35 panels = 739.23 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(739.23 sqft / 3015.30 sqft)(100)= 24.52%∴THE PANELS USE 24.52% OFTHE TOTAL ROOF AREAPVM- PRODUCTION METERUM- UTILITY METERINVERTER TYPE, DIMENSIONS & WEIGHTNUMBER OF INVERTER = 35 MICRO-INVERTERSINVERTER TYPE = ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERSINVERTER WEIGHT = 2.38 LBS / 1.08 KG.INVERTER DIMENSIONS (HXWXD) = 8.3" X 6.9" X 1.2"ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERSLOCATED UNDER EACH MODULEACD- AC DISCONNECTLOGARTO LNFRONT YARDREAR YARD36" FIRE PATHWAY18" FIRE
PATHWAY18" FIRE
PATHWAY36" FIRE PATHWAY36" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY36" FIREPATHWAYROOF #1ROOF #2(N) 3/4" OR GREATEREMT CONDUIT RUN(7/8" ABOVE ROOF)Professional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538123-DEC-2022Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/06/2023dpfannensteinFor each roof plane with a photo-voltaic array, twopathways not less than 36" wide shall be provided fromthe lowest roof edge to ridge on the same roof plane asthe array,on an adjacent roof plane, or straddling thesame and adjacent roof planes. Not fewer than onepathway shall be provided on the street or drivewayside of the house.Not less than an 18" clear setbackis required on both sides of ahorizontal ridge.
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comATTACHMENTDETAILATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS &TRUSSES(OR SEAM) LOCATIONS MAY VARY. INSTALL PERMANUFACTURER(S) INSTALLATION GUIDELINES ANDENGINEERED SPANS FOR ATTACHMENTS2"X6" RAFTERS @24" O
.CENLARGE VIEWPV MODULESCOMP SHINGLE ROOF2.5" MIN.EMBEDMENT5/16" x 4" STAINLESS STEEL LAG BOLTW/ SS EPDM BONDED WASHERNXT HORIZON COMBO CLAMPPV MODULES NXT HORIZON RAIL STRONGHOLD RAIL CLAMPFLASHLOC BASEROOF / DECK MEMBRANECOMP SHINGLE ROOF5/16"-18 x 2"SERRATED FLANGE HEX SCREW~6" HEIGHTADJUSTMENT1.26"~6"1.26"Professional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538123-DEC-2022
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comELECTRICAL LINEDIAGRAMCHANGE AS PER YOUR REQUIREMENTELECTRICAL THREE LINE DIAGRAMSCALE: NTS1SYSTEM SIZE:- 35 x 400W = 14.00 kWDCSYSTEM SIZE:- 35 x 290W = 10.15 kWACSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #VMPIMPVOCISCTEMPERATURECOEFFICIENTOF VocHANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ (400W)37.1310.7745.3011.14-0.27%/°CMODULE DIMENSION74.0" L x 41.1" W x 1.26" DINVERTER SPECIFICATIONSMANUFACTURER / MODEL #QUANTITYNOMINAL OUTPUTVOLTAGENOMINAL OUTPUTCURRENTENPHASE ENERGYIQ8PLUS-72-2-US35240 VAC1.21AAMBIENT TEMPERTURE SPECIFICATIONSRECORDLOW TEMPAMBIENT TEMP(HIGH TEMP 2%)CONDUITHEIGHTCONDUCTORTEMPERATURERATEON/OFF ROOF-28°31°7/8"90° / 75°CONDUCTOR SCHEDULE AND CALCULATIONSTAGLOCATION DESCRIPTION# OF BRANCHCURRENT (A)#C. CARRYINGCONDUCTORWIRESIZEWIRETYPECOND.RATING (A)AMBIENTTEMPCOND. FILLFACTORDERATEDGROUNDSIZECONDUITTYPECONDUITSIZEWIRE RUNFROMBRANCHMAX. MOD. INBRANCH LENGTHINVERTER OUTPUTCURRENT690.8(A)(1)(A)ABRANCH TO J-BOX3121.2118.15212 AWGQ-CABLE300.961.028.806 AWGFREE AIRN/ABJ-BOX TO COMBINER BOX3121.2118.15610 AWGTHWN-2400.960.8030.7210 AWGEMT3/4"CCOMBINER BOX TOINTERCONNECTION1351.2152.9436 AWGTHWN650.941.061.108 AWGEMT3/4"(35) HANWHA Q CELLSQ.PEAK DUO BLK ML-G10+ (400W) MODULES(35) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS(02) BRANCHES OF 12 MODULES &(01) BRANCH OF 11 MODULES CONNECTED IN PARALLEL PER BRANCH(35) ENPHASE ENERGY IQ8PLUS-72-2-USMICROINVERTERS (240V)(LOCATED UNDER EACH PANEL)GNGM*IQ GATEWAYBRANCH TERMINATORE-TERM-10 (TYP.)L1L211 MICRO-INVERTERS IN BRANCH #3L1L220A(N) ENPHASE IQCOMBINER BOX 4(N) JUNCTION BOXABCCL1L2L1L220A15A20AL150AEXISTING GROUNDINGSYSTEMLINE SIDE TAP(E) MAIN BREAKER150A/2P, 240V (E) MAINSERVICE PANEL,150A RATED,120/240VBI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60Hz12 MICRO-INVERTERS IN BRANCH #1L1L2L1L212 MICRO-INVERTERS IN BRANCH #2GNNL2L1L2L160A FUSESMNL2L1GLINELOADNL2L1G(N) PRODUCTIONMETERC(N) AC DISCONNECT60A FUSED,WITH 60AFUSES 240 VACGROUNDING TOBE BONDED WITHNEUTRAL USINGGROUNDINGSCREW
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comWARNING LABELS &PLACARD (E) 150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER (INSIDE)(E) UTILITY METER(N) FUSED AC DISCONNECTPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWNWARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC690.31(D)(2)PHOTOVOLTAIC POWER SOURCELABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.12(B)(3)(3) & NEC 690.59)NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.ELECTRICAL SHOCK HAZARDWARNINGTERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONLABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2020: NEC 706.15(C)(4) & NEC 690.13(B)MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 42.35 AMPS 240 VACLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2020: 690.54SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTINGMEANS TO WHICH THE PV SYSTEMS ARE CONNECTED.PER CODE(S): NEC 2020: IFC 690.56(C)!4"3"PHOTOVOLTAIC AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))THIS EQUIPMENT FED BYMULTIPLE SOURCES TOTALRATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNINGLABEL LOCATION: POINTS OF CONNECTION/BREAKERCODE: NEC 705.12(B)(3)(3)PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)LABEL LOCATION:SERVICE PANEL IF SUM OFBREAKERS EXCEEDS PANEL RATINGNEC 705.12 (B)(3)(2)LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER, INVERTER/DCDISCONNECT IF REQUIRED BY LOCAL AHJ, OROTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2020: 690.56(C)(2)RAPID SHUTDOWN FORSOLAR PV SYSTEM!!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:INVERTERPER CODE: NEC 690.31(E)(N) PV MODULES(N) IQ COMBINER BOX 4CAUTION:MULTIPLE SOURCES OF POWER16163 LOGARTO LN
(N) PRODUCTION METER
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEET
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-10 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-11 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-12 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-13 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-14 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-15 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-16 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS
REVDATEDESCRIPTIONVERSIONUR12-22-2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-17 PROJECT NAMETOM SHEA
16163 LOGARTO LN,
LAKEVILLE, MN 55044 USA
APN# 221450004080
UTILITY: DAKOTA ELECTRIC
ASSOCIATION
AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS