Loading...
HomeMy WebLinkAboutLA210928-MattMoore_Plans_V1_03072023SS6406eadc8bc0e - APPROVEDCOVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEM18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USAREVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-0 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSYSTEM SUMMARY:ROOF TYPE: - COMP SHINGLENUMBER OF LAYERS: - 01ROOF FRAME: - 2"X4" TRUSSES @24" O.C.STORY: - TWO STORYSNOW LOAD : - 50 PSFWIND SPEED :- 109 MPHWIND EXPOSURE:- CEXPOSURE CATEGORY:- IICO-ORDINATES:- 44.684780, -93.235806DESIGN CRITERIA:2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0PV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 ELECTRICAL LINE DIAGRAMPV-5 PLACARDS & WARNING LABELSPV-6ADDITIONAL NOTESPV-7+EQUIPMENT SPEC SHEETSSHEET INDEX(N) 17 - HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES(N) 17 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS(N) JUNCTION BOX(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) AC DISCONNECT 60A FUSED,WITH 30A FUSES, 240 VAC(N) PRODUCTION METER(N) ENPHASE IQ COMBINER BOX 4GOVERNING CODES:PROJECT SITEARRAY LOCATIONGENERAL NOTES·ALL ELECTRICAL WORK SHALL BE PERFORMED BY A QUALIFIED LICENSEDELECTRICIAN AND/OR APPRENTICES WORKING UNDER THE DIRECTSUPERVISION OF THE LICENSED CONTRACTOR.·ALL WORK CARRIED OUT SHALL COMPLY WITH THE SPECIFICATIONS,APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS.·PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL NOTIFYTHE ENGINEER OF AN DISCREPANCIES NOTED AMONG SITE CONDITIONS,MANUFACTURER RECOMMENDATIONS, OR AUTHORITY HAVING JURISDICTION. IFTHE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESEDRAWINGS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF RECORD AWRITTEN "RFI"(REQUEST FOR INFORMATION) PROPOSING AN ALTERNATIVE ORSEEKING CLARIFICATION.·THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OFPLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THEPREMISES AT ALL TIMES.·UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHINGMATERIALS, EQUIPMENT, ACCESSORIES, AND LABOR NECESSARY TO COMPLETEALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.·ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCEWITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTORSHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS,ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLICAUTHORITY REGARDING THE PERFORMANCE OF WORK.·THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY STATED OTHERWISE.·CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA,ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BEAFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TOALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION.·FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FORALL ROOF WORK.·WHEN INSTALLING IN FIRE RATED AREAS, SEAL ALL PENETRATIONS WITH ULLISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALLKEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS.·CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. ALL DEBRIS ANDOTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN ALAWFUL MANNER.·THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS,CURBS, LANDSCAPING AND STRUCTURES NOT PART OF THE SCOPE OF WORKAS IDENTIFIED IN THESE PLANS.·THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FORTHE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION.·DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY AREEXPOSED TO LIGHT, CONTRACTOR SHALL DISABLE THE ARRAY DURINGINSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, ORCOVERING ARRAY WITH AN OPAQUE COVER ACCORDING TO MANUFACTURER'SINSTRUCTION.·CONSTRUCTION LOADING ON THE ROOF, SUCH AS MATERIAL STAGED ON THEROOF, SHALL BE LIMITED TO 20 PSF. CONCENTRATED LOADING SHALL BEAVOIDED TO PREVENT LOCALIZED DAMAGE TO THE ROOF.17 MODULES-ROOF MOUNTED - 6.80 kWDC, 4.93 kWAC2020 NATIONAL ELECTRICAL CODE2018 MINNESOTA STATE BUILDING CODE2020 MINNESOTA RESIDENTIAL CODE2020 MINNESOTA FUEL GAS CODE2020 MINNESOTA MECHANICAL CODE2020 MINNESOTA ENERGY CONSERVATION CODE2020 MINNESOTA FIRE CODEProfessional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538107-MAR-2023STRUCTURAL ONLY PVMMSPUM CB JBACD ~138.86'~56.88'~40.59'~1 3 7 . 5 6 '~62.18'20'-8"66' - 2 "11'-2"26'- 9 " PVMMSPUM CBACD JBSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.NOTE:A.ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALLNOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’SUPPLY OR DEMAND PIPING.JUNCTION BOXJBMSPMAIN SERVICE PANELENPHASE IQ COMBINER 4CBCONDUITGATEPROPERTY LINEFENCELEGENDAC DISCONNECTACDUMUTILITY METERPRODUCTION METERPVMEXISTINGDRIVEWAYP R O P E R T Y L I N E PROPERTY LINEPRO P E R T Y L I N EPROPERTY LINEHIDEAWAY TRAILTWO- STORYHOUSENOTE:-3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF)Professional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538107-MAR-2023STRUCTURAL ONLY 4'-0"37'-9"11"4'-2 " 16'- 2 " 1'-8 " PVMMSPUM CB JBACD REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"174.0"41.1"PHOTOVOLTAIC MODULESHANWHA Q.CELLS Q.PEAK DUO BLKML-G10+ (400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 17 MODULESMODULE TYPE = HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10+ (400W)MODULE WEIGHT = 48.5 LBS / 22.0 KG.MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SFUNIT WEIGHT OF ARRAY = 2.30 PSFARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#117359.05701.1451.21ROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#130°207°2"x4"24" O.C.NOTE: ACTUAL ROOF CONDITIONS ANDTRUSSES (OR SEAM) LOCATIONS MAY VARY.INSTALL PER MANUFACTURER(S) INSTALLATIONGUIDELINES AND ENGINEERED SPANS FORATTACHMENTS.- TRUSSES· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL10NXT HORIZON RAIL 168" DARKSPLICE04NXT HORIZON RAIL SPLICEUNIVERSAL CLAMP46NXT HORIZON COMBO CLAMP -DARKRAIL CLAMP36STRONGHOLD RAIL CLAMP DRKACCESSORIES20NXT HORIZON RL & CLMP CAP KITATTACHMENT39UNIRAC FLASHLOC ATTACHMENTMLPE & GROUNDING23NXT HORIZON MLPE & LUG CLAMPINVERTER TYPE, DIMENSIONS & WEIGHTNUMBER OF INVERTER = 17 MICRO-INVERTERSINVERTER TYPE = ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERSINVERTER WEIGHT = 2.38 LBS / 1.08 KG.INVERTER DIMENSIONS (HXWXD) = 8.3" X 6.9" X 1.2"ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERSLOCATED UNDER EACH MODULEARRAY AREA & ROOF AREA CALC'SAREA OF NEW ARRAY(Sq. Ft.)AREA OF ROOF(PLANVIEW)(Sq. Ft.)TOTAL ROOF AREACOVERED BY ARRAY %359.052345.1615%15%ROOF AREA (ARRAY <33% OF ROOF AREA)HIDEAWAY TRAILFRONT YARDREAR YARDJUNCTION BOXJBMSPMAIN SERVICE PANELENPHASE IQ COMBINER 4CBCONDUITLEGENDAC DISCONNECTACDUMUTILITY METERPRODUCTION METERPVM- CHIMNEY- VENT, ATTIC FAN(ROOF OBSTRUCTION)NOTE:-3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF)18" FIRE PATHWAY18" FIRE PATHWAY36" F I R E P A T H W A Y 36" FIRE PATHWAYROOF #1TILT - 30° AZIMUTH - 207°(N) (39) UNIRAC FLASHLOCATTACHMENTS SPACED AT 48" O.C.Professional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538107-MAR-2023STRUCTURAL ONLYConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/31/2023dpfannensteinFor each roof plane with a photo-voltaic array, twopathways not less than 36" wide shall be provided fromthe lowest roof edge to ridge on the same roof plane asthe array,on an adjacent roof plane, or straddling thesame and adjacent roof planes. Not fewer than onepathway shall be provided on the street or drivewayside of the house.Not less than an 18" clear setbackis required on both sides of ahorizontal ridge. REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comATTACHMENTDETAILATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS2"X4" TRUSSES @24" O .CENLARGE VIEWPV MODULESCOMP SHINGLE ROOF2.5" MIN.EMBEDMENT5/16" x 4" STAINLESS STEEL LAG BOLTW/ SS EPDM BONDED WASHERNXT HORIZON COMBO CLAMPPV MODULES NXT HORIZON RAIL STRONGHOLD RAIL CLAMPFLASHLOC BASEROOF / DECK MEMBRANECOMP SHINGLE ROOF5/16"-18 x 2"SERRATED FLANGE HEX SCREW~4" HEIGHTADJUSTMENT1.26"~4"1.26"Professional EngineerI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that I ama duly Licensed Professional Engineer under the laws of thestate of Minnesota.Signature: Typed or Printed Name: Saddam AhmadDate: License Number: 5538107-MAR-2023STRUCTURAL ONLY REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comELECTRICAL LINEDIAGRAMCHANGE AS PER YOUR REQUIREMENTELECTRICAL THREE LINE DIAGRAMSCALE: NTS1SYSTEM SIZE:- 17 x 400W = 6.80 kWDCSYSTEM SIZE:- 17 x 290W = 4.93 kWACSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #VMPIMPVOCISCTEMPERATURECOEFFICIENTOF VocHANWHA Q.CELLS Q.PEAK DUOBLK ML-G10+ (400W)37.1310.7745.3011.14-0.27%/°CMODULE DIMENSION74.0" L x 41.1" W x 1.26" DINVERTER SPECIFICATIONSMANUFACTURER / MODEL #QUANTITYNOMINAL OUTPUTVOLTAGENOMINAL OUTPUTCURRENTENPHASE ENERGYIQ8PLUS-72-2-US17240 VAC1.21AAMBIENT TEMPERTURE SPECIFICATIONSRECORDLOW TEMPAMBIENT TEMP(HIGH TEMP 2%)CONDUITHEIGHTCONDUCTORTEMPERATURERATEON/OFF ROOF-27°32°7/8"90° / 75°CONDUCTOR SCHEDULE AND CALCULATIONSTAGLOCATION DESCRIPTION# OF BRANCHCURRENT (A)#C. CARRYINGCONDUCTORWIRESIZEWIRETYPECOND.RATING (A)AMBIENTTEMPCOND. FILLFACTORDERATEDGROUNDSIZECONDUITTYPECONDUITSIZEWIRE RUNFROMBRANCHMAX. MOD. INBRANCH LENGTHINVERTER OUTPUTCURRENT690.8(A)(1)(A)ABRANCH TO J-BOX2091.2113.61212 AWGQ-CABLE300.961.028.806 AWGFREE AIRN/ABJ-BOX TO COMBINER BOX2091.2113.61410 AWGTHWN-2400.960.8030.7210 AWGEMT3/4"CCOMBINER BOX TO ACDISCONNECT1171.2125.71310 AWGTHWN350.941.032.9010 AWGEMT3/4"DAC DISCONNECT TOINTERCONNECTION1171.2125.7136 AWGTHWN650.941.061.108 AWGEMT3/4"(17) HANWHA Q.CELLSQ.PEAK DUO BLK ML-G10+ (400W) MODULES(17) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS(01) BRANCH OF 09 MODULES &(01) BRANCH OF 08 MODULES CONNECTED IN PARALLEL PER BRANCH(17) ENPHASE ENERGY IQ8PLUS-72-2-USMICROINVERTERS (240V)(LOCATED UNDER EACH PANEL)GNGM*IQ GATEWAYBRANCH TERMINATORE-TERM-10 (TYP.)L1L208 MICRO-INVERTERS IN BRANCH #2L1L220A(N) ENPHASE IQCOMBINER BOX 4(N) JUNCTION BOXABDDL1L2L1L220A15AL200AEXISTINGGROUNDINGSYSTEMLINE SIDE TAP(E) MAIN BREAKER200A/2P, 240V (E) MAINSERVICE PANEL,200A RATED,120/240VBI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60Hz09 MICRO-INVERTERS IN BRANCH #1MNL2L1GLINELOADNL2L1G(N) PRODUCTIONMETERCGNNL2L1L2L130A FUSES(N) AC DISCONNECT60A FUSED,WITH 30AFUSES 240 VACGROUNDING TO BEBONDED WITHNEUTRAL USINGGROUNDING SCREW REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comWARNING LABELS &PLACARD (E) 200A MAIN SERVICEPANELWITH (E) 200A MAINBREAKER(E) UTILITY METER(N) FUSED AC DISCONNECTPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC690.31(D)(2)PHOTOVOLTAIC POWER SOURCELABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.12(B)(3)(3) & NEC 690.59)NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.ELECTRICAL SHOCK HAZARDWARNINGTERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONLABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2020: NEC 706.15(C)(4) & NEC 690.13(B)MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 20.57 AMPS 240 VACLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2020: 690.54SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTINGMEANS TO WHICH THE PV SYSTEMS ARE CONNECTED.PER CODE(S): NEC 2020: IFC 690.56(C)!4"3"PHOTOVOLTAIC AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))THIS EQUIPMENT FED BYMULTIPLE SOURCES TOTALRATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNINGLABEL LOCATION: POINTS OF CONNECTION/BREAKERCODE: NEC 705.12(B)(3)(3)PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER, INVERTER/DCDISCONNECT IF REQUIRED BY LOCAL AHJ, OROTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2020: 690.56(C)(2)RAPID SHUTDOWN FORSOLAR PV SYSTEM!!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:INVERTERPER CODE: NEC 690.31(E)(N) PV MODULESCAUTION:MULTIPLE SOURCES OF POWER18222 HIDEAWAY TRAIL(N) PRODUCTION METER(N) IQ COMBINER BOX 4 REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEET REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-11 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-12 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-13 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-14 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-15 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-16 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR02-16-2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-17 PROJECT NAMEMATT MOORE 18222 HIDEAWAY TRAIL, LAKEVILLE, MN 55044 USA APN# 225721005060 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS