HomeMy WebLinkAboutLA208644 - 5844 Upper 179th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
1'-6"6:121'-6"1'-6"1'-6"6:129' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR9' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR9' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR6126121'-6"1'-6"6126126126:126:121'-6"1'-6"1'-6"6:126:126126126121'-6"1'-6"1'-6"6:1261261261261215NOTES:1.) ELEVATIONS ARE A ARTIST RENDERING ONLY, ACTUAL ELEVATION MAY VARY2.) ALL OVERHANGS SHALL BE 1'-6" TYPICAL UNLESS NOTED OTHERWISE3.) ALL RAKES SHALL BE 1'-6" TYPICAL UNLESS NOTED OTHERWISE4.) ALUMINUM FASCIA AND SOFFITS ON ALL SIDES5.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESSOTHERWISE NOTED09/10/22 -ORIGINALRESIDENCE FOR: Marty and Brittany Schommer
5844 Upper 179Th St W., Lakeville MN 55044
Lot 11, Block 3, Knob Hill of Lakeville Third Addition FRONT ELEVATION 1/4" = 1'-0"LEFT ELEVATION 1/8" = 1'-0"RIGHT ELEVATION 1/8" = 1'-0"REAR ELEVATION 1/8" = 1'-0"LOWER LEVEL1,308 SQ FTMAIN LEVEL1,508 SQ FTUPPER LEVEL(GAME ROOM) 864 SQ FTTOTAL 3,680 SQ FTGARAGE 864 SQ FTTOTAL4,544 SQ FT11/06/22 -REVISED11/08/22 -REVISED11/28/22 -REVISED04/24/23 -ICF NOTEConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode11/28/2022dmathews*Revised to ICF Foundation 4/25/23 dm
18" DIAMETER CONCRETE FROST FOOTINGS - 42" DEPTH6X6 POST ON12" CONC. ROUND COLUMNW/12"X24"X24" CONC. FTG.12'36'46'55'-10"7'-6"9'-814"9'2'2'9'2'-6"9'2'-6"8'20'-512"56'9'-2"
24'
6'-10"
24'
30'
48'
4'-814"9'-2"12'-214"27'-734"SUMP9 1/2 TJI
SPACING BY MFG6"3'
A AIN-FLOOR RADIANT HEATIN-FLOOR RADIANT HEAT24'-034"7'-914"7'-914"12'16'-234"16'2" RIDGID INSULATIONFOUNDATION WALL STEP8" STUD WALL ABOVE (FLUSHWITH 2" RIDGID INSULATION)2" RIDGID INSULATION2" RIDGID INSULATIONUNEXCAVATED3'-4" H X 8" W ICF POURED CONCRETE FROST WALLSILL SEALER1 TREATED PLATEON 16" X 8" CONCRETE FOOTINGSREBAR PER ENG. REQUIREMENTS3'-4" H X 8" W ICF POURED CONCRETE FROST WALLSILL SEALER1 TREATED PLATEON 16" X 8" CONCRETE FOOTINGSREBAR PER ENG. REQUIREMENTS3'-4" H X 8" W ICF POURED CONCRETE FROST WALLSILL SEALER1 TREATED PLATEON 16" X 8" CONCRETE FOOTINGSREBAR PER ENG. REQUIREMENTS612"
2'-134"9'-4"3-2X10 BEAM2'-334"2'-8"10'-2"9'-412"13'-534"3'13'-1014"42'-1134"21'-712"1'-4"3'-814"1'-4"FOUNDATION WALL STEPB B2-2X10 BEAMIN-FLOOR RADIANT HEATFLOOR DRAINFLOOR DRAIN16'39'-10"2'25RESIDENCE FOR: Marty and Brittany Schommer
5844 Upper 179Th St W., Lakeville MN 55044
Lot 11, Block 3, Knob Hill of Lakeville Third AdditionFOUNDATION PLAN 1/4" = 1'-0"NOTES:1.) ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2X10 UNLESS OTHERWISE NOTED2.) STAIR TREAD CUT SHOWN AT 10 1/4" RUN AND 7 3/4 MAX RISE3.) ALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING UNLESS OTHERWISE NOTED4.) ALL INTERIOR DIMENSION ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED5.) ALL EXTERIOR WALLS ARE 2X6 STUDS UNLESS OTHERWISE NOTED (THERE IS ONE 8"WALL ON THE LOWER LEVEL)6.) GARAGE WALL 2X6 STUDS7.) TRUSS AND FLOOR JOIST MANUFACTURER TO VERIFY SIZE AND SPACING OF JOIST ANDTRUSSES8.) 4" RETURNS ON ALL DOORS UNLESS OTHERWISE NOTED9.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESSOTHERWISE NOTED10.) FOUNDATION WALLS WILL BE 8" ICF WALLS09/10/22 -ORIGINAL11/06/22 -REVISED11/08/22 -REVISED11/28/22 -REVISED04/24/23 -ICF NOTEUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
BWL-2 BWL-2
FL DRBEDROOM.11'-7" x 11'-11"MECH.ROOMSTOVETOP30"KITCHENSINK36"WALLOVEN30"PANTRYD/W24"24"30"3'-0"LIVING/DINING ROOM20'-5" x 13'-0"FRIDGE36"5'-214"TUB/SHOWERCL
FIRE PLACE24"LINEN
CABINET
CL2'-4"TUBLAUNDRYBEDROOM.11'-7" x 11'-11"2'-4"BEDROOM.11'-0" x 11'-10"46'56'TUBWHHVACIFHWSW2'-6"
2'-6"2'-6"2'-4"2'-4"2'-6"2'-6"2'-6"5'-0"5'-0"3'-0"2'-8"
3'-0"6'-0"5'-0"9' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR9' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR2-9 1/2 LVL BEAM2-9 1/2 LVL BEAM2-9 1/2 LVL BEAM1 STALL GARAGE11'-5" x 19-6"6"4'-912"4'-612"1'-3"1'-3"2'2'9'2'-6"9'2'-6"11'8'12'36'56'20'-314"2'-512"9'-3"5'3'-612"
24'24'
48'
9'9'7'30'6'-334"5'-612"8'-214"5'-212"DH 4'-0" X 5'-0"6'-3" X 3'-6"DH 3'-0" X 6'-0"DH 4'-0" X 6'-0"DH 3'-0" X 6'-0"2'-6"
3-2x10
2-2x102-2x102-2x102-2x102-2x102'-8"18" FLOOR TRUSSES
SPACED 19.2" O.C.
18" FLOOR TRUSSES
SPACED 19.2" O.C.18" FLOOR TRUSSESSPACED 19.2" O.C.3'-734"6'-012"3'-314"2'-114"3'-1"3'-9"3'-9"12'-414"5'-612"11'-512"5'-512"12'-734"2'-412"2'-412"12'-714"9'7'-6"2'-8"5"4'-834"4'-612"1'1'1'1'
6'-234"18" FLOOR TRUSSESSPACED 19.2" O.C.6'-412"
18" FLOOR TRUSSES
SPACED 19.2" O.C.
18" FLOOR TRUSSES
SPACED 19.2" O.C.
4'-212"12'-714"SL 5'-0" X 6'-0"8'-834"3'-712"3'-1112"7'-114"2X6 WETWALL STUDS 16" O.C.8'-5"6'-1012"2X6 BEARING WALLSTUD @ 16" O.C.2X6 BEARING WALLSTUD @ 16" O.C.2X4 STUD 1/2 WALL.3'-834"5'-534"2'-412"10'-234"3'-612"
3'-114"3'-3"3'-6"8'-012"2X6 STUD WALL 16" O.C.4'-6"
3'8'-10" 3-2X12 3-2X124'-6"4'-6"MIN. 15" FROM CL OF TOILETTO ANY OBSTRUCTION. 24"MIN. IN FRONT OF TOILETTUB/SHOWERMIN. 15" FROM CL OF TOILETTO ANY OBSTRUCTION. 24"MIN. IN FRONT OF TOILET3'-1034"W.I.CBATHROOMBATHROOMA A
B B
BWL-4 BWL-4
BWL-1 BWL-1
BWL-3 BWL-3BWL-ABWL-ABWL-BBWL-BBWL-CBWL-C4' W.S.P.24'16'16'12'6X6 TREATED POSTS WITH 18" DIAMETER FROST FOOTINGS8'8'2X8 STUDS @ 16" O.C.C.S-W.S.P.-P.F.C.S-W.S.P.-P.F.4' W.S.P.
4' W.S.P.
4' W.S.P.
4'-814"2'-334"
4' W.S.P.4' W.S.P.C.S-W.S.P.-P.F.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.2x8 JOISTS
16" O.C.9' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR2 STALL GARAGE22'-11" x 22'-11"DH 2'-6" X 4'-0"FLOOR DRAINFLOOR DRAIN3'3'
3'-9"
BUILT-IN
BOOK
SHELVES
BUILT-IN
BOOK
SHELVES 1'-6"MIN.3-2x103'-312"5'-214"40'16'SCREENED PATIO16' x 12'2'LOWER LEVEL, ENTRY WAY AND GARAGE 1/4" = 1'-0"8' CEILINGS LOWER LEVELNOTES:1.) ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2X10 UNLESS OTHERWISE NOTED2.) STAIR TREAD CUT SHOWN AT 10 1/4" RUN AND 7 3/4 MAX RISE3.) ALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING UNLESS OTHERWISE NOTED4.) ALL INTERIOR DIMENSION ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED5.) ALL EXTERIOR WALLS ARE 2X6 STUDS UNLESS OTHERWISE NOTED (THERE IS ONE 8"WALL ON THE LOWER LEVEL)6.) GARAGE WALL 2X6 STUDS7.) TRUSS AND FLOOR JOIST MANUFACTURER TO VERIFY SIZE AND SPACING OF JOIST ANDTRUSSES8.) 4" RETURNS ON ALL DOORS UNLESS OTHERWISE NOTED9.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESSOTHERWISE NOTED35RESIDENCE FOR: Marty and Brittany Schommer
5844 Upper 179Th St W., Lakeville MN 55044
Lot 11, Block 3, Knob Hill of Lakeville Third Addition 09/10/22 -ORIGINAL11/06/22 -REVISED11/08/22 -REVISED11/28/22 -REVISED04/24/23 -ICF NOTEFANFANSmokeCOSmokeCOSmokeSmokeSmokeTemper
BWL-BBWL-B4' W.S.P.GAME ROOM22'-11" x 34'-11"LIVING/DINING ROOMOFFICE/DEN11'-6" x 11'-0"2'-0"2'-0" FLOOR TO CEILINGCABINET WITH WATERSUPPLY IN WALLDRYERTUB
LAUNDRYCLSHOWER3'-6"X 8'-10"MASTER BEDROOM14'11" x 14'-3"FRIDGE30"36" BASE
SINK
36"18"KITCHEN46'56'48'
2'-6"
LINEN
CABINET 24"D/WPANTRY8'-10"
2'-4"
LINEN
CABINET
2'-4"72"2'-4"3'-6"18"24"36"12"3'3'-312"1'FIRE PLACECTR ON WALL
2'-4"2'-6"
2'-6"2'-8"6'-934"5'6'-512"11'-834"4'-814"9'30'7'9'8'-612"4'-614"3'-612"40'16'11'-514"
24'24'6"6'-6"9'-4"8'12'36'56'11'-6"11'-6"6'-6"6'-0" X 4'-0"6'-0" X 4'-0"6'-0" X 4'-0"10'-0" X 5'-0"(DH WITH 5'X5' PICTURE WINDOW IN CENTER)DH 2'-0" X 3'-0"4'-0" X 5'-0"4'-0" X 5'-0"2-2x102-2x102-2x102-2x102-2x102-2x10PD 6'-0" X 6'-8"2- 11 7/8 LVL2-2x102-2x10 19'-1"6'-314"1'-7"12'-512"33'-1034"6'-114"1'1'1'1'7'-6"2'-8"8'-10"3'3'-612"
14'-1134"6'-134"5'-034"5'-412"3'-1012"7'-812"6'-412"3'-412"4'-234"2'-1012"
6'-134"WOOD RAILING8'-1014"ϰϱΣ
4'-1114"7'-814"
2'-912"3'-712"4'-212"MIN. 15" FROM CL OF TOILETTO ANY OBSTRUCTION. 24"MIN. IN FRONT OF TOILETMIN. 15" FROM CL OF TOILETTO ANY OBSTRUCTION. 24"MIN. IN FRONT OF TOILETCL
6'-134"
9'-514"W.I.CMASTERBATH1/2 BATHROOF TRUSSES
SPACED 24" O.C.
ROOF TRUSSES
SPACED 24" O.C.
ROOF TRUSSESSPACED 24" O.C.ROOF TRUSSESSPACED 24" O.C.ROOF TRUSSESSPACED 24" O.C.A A
B B
BWL-4 BWL-4
BWL-1 BWL-1
BWL-2 BWL-2
BWL-3 BWL-3BWL-ABWL-ABWL-CBWL-C24'16'16'12'(3)2x8 FLUSH BEAMDECK16'-0" x 12'-0"TREATED 2X8 JOIST @ 16" O.C.6X6 TREATED POSTS WITH 18" DIAMETER FROST FOOTINGS8'8'(3)2x8 FLUSH BEAM16'-2x8 DECK LEDGER2'-334"4' W.S.P.4' W.S.P.4' W.S.P.
4' W.S.P.
4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.C.S-W.S.P.-P.F.3.5' W.S.P.4' W.S.P.3.5' W.S.P.4'-0" X 5'-0"CENTER WINDOWBETWEEN COLUMNS3.5' W.S.P. 10" OVERHANGPLUMBING FORFUTURE WET BAR2'-012" 2X2 STUD WALL 2 1/2" RETURNSRANGE3-2x10HEADER FLUSH3-2x10 BEAM2-2x10 BEAMMAIN LEVEL AND ABOVE GARAGE 1/4" = 1'-0"9' CEILINGS MAIN LEVEL- 9' CEILING ABOVE GARAGE45RESIDENCE FOR: Marty and Brittany Schommer
5844 Upper 179Th St W., Lakeville MN 55044
Lot 11, Block 3, Knob Hill of Lakeville Third AdditionNOTES:1.) ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2X10 UNLESS OTHERWISE NOTED2.) STAIR TREAD CUT SHOWN AT 10 1/4" RUN AND 7 3/4 MAX RISE3.) ALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING UNLESS OTHERWISE NOTED4.) ALL INTERIOR DIMENSION ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED5.) ALL EXTERIOR WALLS ARE 2X6 STUDS UNLESS OTHERWISE NOTED (THERE IS ONE 8"WALL ON THE LOWER LEVEL)6.) GARAGE WALL 2X6 STUDS7.) TRUSS AND FLOOR JOIST MANUFACTURER TO VERIFY SIZE AND SPACING OF JOIST ANDTRUSSES8.) 4" RETURNS ON ALL DOORS UNLESS OTHERWISE NOTED9.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESSOTHERWISE NOTED09/10/22 -ORIGINAL11/06/22 -REVISED11/08/22 -REVISED11/28/22 -REVISED04/24/23 -ICF NOTEGirderSmokeSmokeCOFANFANFAN
GARAGE FLOORELEVATION 942.551'-6"GRADE6"
3'-6"GAME ROOM8'-2"18" FLOOR TRUSSES SPACING BY MFG5/8" GYP. BOARD1'-6"R-50 INSULATIONENERGY HEELALUM. FASCIAALUM. VENTED SOFFITASPHALT SHINGLES15# FELT1/2" SHEATHINGROOF TRUSSES3/4" T&G SUBFLOOR9 1/2 TJI SPACING BY MFGLOWER LEVEL FLOORELEVATION 940.00TOP OF FOUNDATION 943.00GARAGEHVAC SOFFIT8'-71316" (6'-8" MIN)3-2x10 HEADER(FLUSH)612KITCHENBATHROOMLAUNDRY/PANTRY9'-1158"9'-118"
9'-118"ENERGY HEELALUM. FASCIAALUM. VENTED SOFFIT612SCREENED PORCHR-21 INSULATION AND VAPOR BARRIER612ENTRYWAY13'-1112"6'-8"(MIN)9 1/2 TJI SPACING BY MFG9'-118"GRADE4'-1038"(2) 2X10 BEAM(2) 2X10 BEAM(3) 2X10 BEAM(3) 2X10HEADER(3) 2X12 BEAM2X8 JOISTTRUSS BEARING6:126:126:126:126:126:126:123 1/2" CONC. SLAB OVERPEX IN FLOOR HEAT2" -25 PSI RIDGID FOAM4" MIN. LAYER OF RIVER ROCK2" RIDGID INSUL4" DRAIN TILEW/SILT ROCKHORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X6 STUDS @ 16" O.C.R-21 INSULATION6"GRADE3'-4" X 8" ICF POURED CONC. WALLW/ REBAR PER CODE1- 2X8 TREATED SILL PLAT16" X 8" CONC. FTGSWATER PROOFINGGRANULAR FILL3'-6"3/4" T&G SUBFLOOR5/8" GYP. BOARDRIM JOISTR-21 SPRAY FOAM3'-4" X 8" ICF POURED CONC. WALLW/ REBAR PER CODEGRADE16" X 8" CONC. FTGS2" RIDGID INSULWATER PROOFINGGRANULAR FILL4" DRAIN TILEW/SILT ROCK2 X 8 TREATED SILL PLATALUM. FASCIAALUM. VENTED SOFFITASPHALT SHINGLES15# FELT1/2" SHEATHINGROOF TRUSSES1'-6"R-50 INSULATIONENERGY HEEL612HORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X6 STUDS @ 16" O.C.R-21 INSULATION1/2" GYP. BOARD6"18" TRUSS SPACING BY MFG9'-118"8'-2"2x4 WALL W. 1/2 GYP. BOARD3/4" WOOD CAPHORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X8 STUDS @ 16" O.C.R-21 INSULATION1/2" GYP. BOARD3'-6"3 1/2" CONC. SLAB OVERPEX IN FLOOR HEAT2" -25 PSI RIDGID FOAM4" MIN. LAYER OF RIVER ROCK55RESIDENCE FOR: Marty and Brittany Schommer
5844 Upper 179Th St W., Lakeville MN 55044
Lot 11, Block 3, Knob Hill of Lakeville Third Addition PASSIVE RADON SYSTEM3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLABTO MIN. 12" ABOVE ROOF.MUST BE RUN THRUCONDITIONED SPACEPIPE CAN BE CONNECTEDTO SUMP SYSTEM ORHAVE "T" FITTING(MIN.10'-0" EACH WAY) INGRAVEL UNDER SLABEND OF PIPE MUST BEMIN. 10'-0" AWAY FROMANY WINDOW OR OTHEROPENING THAT IS LESSTHAN 2'-0" BELOW END OFPIPE. END OF PIPE MUSTALSO BE MIN. 10'-0" AWAYFROM ANY WINDOW OROTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUSTBE LEFT AROUND PIPE INATTIC SPACE TO ADD FAN.SPACE MUST BE MIN. 24"CENTERED ON AXIS OF PIPEW/ MIN. 3'-0" VERTICALSPACEA SINGLE PIPE CAN BEUSED IF ALL SOIL GASES INDWELLING CAN FLOWFREELY BETWEEN ALLLEVELS OF FOUNDATIONTHIS INCLUDES INTERIORFOOTINGS AND OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE ATLEAST ONCE PER FLOORAND IN ACCESSIBLE ATTICSWITH "RADON REDUCTIONSYSTEM""A"-FULL SECTION 1/4" = 1'-0""B"-ENTRYWAY SECTIONS 1/4" = 1'-0"TYP. WALL SECTION 1/2" = 1'-0"TYP. WALKOUT SECTION 1/2" = 1'-0"ROOF PLANS 1/8" = 1'-0"09/10/22 -ORIGINAL11/06/22 -REVISED11/08/22 -REVISED11/28/22 -REVISED04/24/23 -ICF NOTE