Loading...
HomeMy WebLinkAboutLA211193 - 17277 Durham Dr - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022CAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" VINYL TRIM 5" VINYL TRIM5" VINYL TRIM3 1/2" VINYL TRIMREFSIDING LEGENDALAP SIDING "B"LAP SIDING "A"PRODUCTCBD5" TRIM - VINYL LINEALNOT USEDE6 1/2" VINYL BEAD BD1.0XSIENNA x423-GRB ROOF PLN:1-10-23-LLPC#1078: 2-8-23-LLx403 to x423: 3-1-23-LLPERMIT/CONSTRUCT:3-22-23-AF20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-7272CUST:SPEC HOMEX423-DA D.R. HORTON COMPANYTYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN5/4" x 3" - WOODGRAINOVER5/4" x 10" - WOODGRAINWOODGRAIN PANEL5/4" x 3" - WOODGRAIN5/4" x 10" - WOODGRAIN10" SQUARE COLUMN9 1/2"9 1/2"6x6 POSTBLOCKING2x4 TREATED1/2" OSB4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)4/4" x 2" - WOODGRAINCORNER TRIM(SIDES)4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)2"=1'-0"1/4"=1'-0"30°SIENNA X423 D FRONT63 SQ. FT. STONE (13.5%)64 SQ. FT. WINDOW (13.7%)XXXXXA1'-0"1xSTEEL PANEL OVERHEAD DOORADDRESS NUMBER5:12 PITCHA1'-0"10 7/16"4:12 PITCH4:12 PITCHFALSE CORNERRAIN DIVERTER5:12 PITCHFALSE CORNER FALSE CORNER 81281212'-0"4'-6"CC7'-8"4'-0"ROOF PLAN-5 FT GARAGE1/8"=1'-0"6' RIDGE VENT DD1'-0"1'-0"1'-0"1'-0"AA1'-0"1'-0" 1'-0"4:1216' RIDGE VENT5:125:121'-0"1'-0"AABB10' RIDGE VENT5:1214'-0"8:128:124:124'-10"DD1'-0"1'-0"4:124:12VENTROOF4'-0"A4:12 PITCHLEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"1/8"=1'-0"ELEV W/ ENLARGED GARAGEASPHALT SHINGLESFLASH OVER ALL EXT OPGS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R8061'-0"5:12 PITCH1'-0"A42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEA1246 3/4"5:12 PITCH42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE1241'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE7 7/16"1241241'-0"1258:12 PITCH7 7/16"1251251248:12 PITCH1'-8"4:12 PITCH1'-0"PERMIT/CONSTRUCT PLANS17277 DURHAM DRIVELOT 40 BLOCK 6 - BROOKSHIREConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/11/2023shutchins2020 MN BldgCode These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C3.0XSIENNA x423-GRB ROOF PLN:1-10-23-LLPC#1078: 2-8-23-LLx403 to x423: 3-1-23-LLPERMIT/CONSTRUCT:3-22-23-AF6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK, 3'-6" HIGH14"x8" CONC. FTG.POURED CONC. WALLFOUNDATION PLAN1/4"=1'-0"TREATED BOTTOM PLATE4" CURB, 1" LEDGE EA SIDE16x8 CONC FTGANCHORS AT 6'-0" O.C.2x4 STUDS AT 16" O.C.2x4 BRNG WALL ABOVE12'-0"8'-6"35'-0"40'-6" 14'-1 3/4" 40'-6" 16'-6"21'-0"14'-0"24'-0"UNEXCAVATED29'-0"2'-4 1/2"16'-3"16'-3" M.O.2'-0" 3'-5 1/2"3'-5 1/2"6'-1"4'-5"3'-8 3/4"2'-9"7'-9"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE7'-3"6'-7 1/4" 5'-6"30x30x12CONC. PAD FTG.24x24x8CONC. PAD FTG.9'-8"10'-6"4" 6"6"TREATED BOTTOM PLATE6" WIDE, 3'-6" HIGH CONC WALL16x8 CONC FTGANCHORS AT 6'-0" O.C.2x6 STUDS AT 16" O.C.2x6 BRNG WALL ABOVEUNEXCAVATEDCONC PAD FTG24x24x86" CURB, 2" INT. LEDGE,POURED CONC. WALL18"x8" CONC. FTG.10" THICK, 3'-6" HIGH2" GARAGE SLAB LEDGE6" CURB, 2" INT. LEDGE,POURED CONC. WALL18"x8" CONC. FTG.10" THICK, 3'-6" HIGH2" EXT. LEDGE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" INT. LEDGE,POURED CONC. WALL18"x8" CONC. FTG.10" THICK, 3'-6" HIGH2" GARAGE SLAB LEDGE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGHFILL16"x8" CONC. FTG.MIN. 3'-6" BELOW GRADEPOURED CONC. WALL6" THICK6'-0"6'-6"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE2'-4 1/2"CONC PAD FTG24x24x85'-0"5'-0"22'-0"2'-0"CONC PAD FTG24x24x84'-7 1/4"F.D.WATER MAINSEWERCLEANOUTRADONFOR KITCHEN ISLANDSLEEVE/CONDUITPOINT LOAD ABOVE36x36x12 CONC. PAD FTG5'-4"#5 BARS EACH WAY @ 12" O.C.3" FROM THE BOTTOM36x36x12 CONC. PAD FTG#5 BARS EACH WAY @ 12" O.C.3" FROM THE BOTTOMPERMIT/CONSTRUCT PLANS17277 DURHAM DRIVELOT 40 BLOCK 6 - BROOKSHIREPLAN OPTIONSSLAB ON GRADE5FT GARAGE BUMPOUT40'-0"UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 14'-0"7'-0"10'-6"2w 3050 SH1'-6"3'-6"These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C4.0XSIENNA x423-GRB ROOF PLN:1-10-23-LLPC#1078: 2-8-23-LLx403 to x423: 3-1-23-LLPERMIT/CONSTRUCT:3-22-23-AFLIVINGROOMDININGHD-FLR786 SQ. FT.NOTES:-9'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 7'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR14'-0"x8'-0"CONC PATIOLFT-RGT DIRECTION2ND FLOOR PLAN1/4"=1'-0"NOTES:-8'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR1056 SQ. FT.LIVING AREA2x6 WALL2-6TOWEL BAR1ST FLOOR PLAN1/4"=1'-0"35'-0"11'-8"40'-6"29'-0"14'-7 1/2"7'-2"40'-6" 16'-6" 13'-1 3/4"3'-4 1/4"16x7 OVERHEAD DOOR21'-0"10'-6"10'-6"14'-0"11'-6"6'-0"3'-6"2x6 BRNG WALL20'-0"23'-0"2-8PED.PWDRHD-FLR7'-3 1/2"3'-6"3'-6"UP 16 R2W 3050 SH3050 SH6'-2"2'-3"12'-1" INSIDE FRAMING20 AMP.MICRO HOODCIRCUITRANGEREF.KITVENT HOODTO OUTSIDEAHUMETERRISERF.D.6'-1"6'-0" CABTS.3'-6" TOP6'-4" TOP 3'-3"3'-3"8'-4"2'-0"4'-3 1/2"3'-6"35'-0"13'-3"40'-6" 29'-0" 14'-7 1/2"7'-2"34'-0" 11'-4" 40'-6" 6'-6"5'-0" 7'-3 1/2"6'-2"3'-6"3'-6"W/ WOOD CAPHALF WALLDN 16 R34x60 FBGL SHWRTPH 9'-1"12'-8"60"BEDRM #1BEDRM #2BATH #2HD-FLR36"5-0 FBGLTUB/SHWR2'-10"TPHTOWEL BARLAU.HD-FLRDRYERWASHERW.S.2'-10"6'-0"11'-4"LOFTBEDRM #321'-0"W.I.C.CPT.BATH #1HD-FLRSTORAGE2'-6" 3'-10 3/8" 24'-0" 21'-0"TOWEL RING6'-4"2'-6"2'-8"6'-5"5'-0"8'-0"4'-6"2'-2"3'-10"2'-2"7'-0"7'-0"14'-0"35'-0"7'-1" 3'-7 3/4" 1'-10 1/2"3'-5"6'-1"4'-11 3/4" 5'-3"6'-1" 2x64'-6"2'-9 1/4"7'-1"10'-6"3'-6"10'-0"3'-10"MFD TRUSSES AT 24" O.C. MFD TRUSSES AT 24" O.C. 14" MFD FLOOR TRUSSESINSTALL PER MFRS SPECSWIPMECH5'-3 1/2"4'-5"RADONVENT PIPERADONVENT PIPE22x30ATTICACCESSSILLCOCKA/CVERSALAM BEAM2-42-42-82-82-42-43-0 DR2-42-42-42-42-42-82-65-02-62-64-02W 3050 SH3050 SH3050 SH 3040 SH3040 SH3040 SH6068 SGD1'-2"3'-10"SINKDW5'-10"2'-6"3'-8"8'-6"29'-0"TEMPTPH1'-2"CPT.CPT.CPT.CPT.CPT.HD-FLRHD-FLRFOYERHD-FLR6'-6"6'-1"3'-7 3/4" TEMP2x6 BRNG WALL16" WIDE DROPPED SOFFIT(SEE SECTION)DROPPED BEAM5'-4"8"6'-0"CONC STOOP36 SQ. FT.PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN3'-6"3'-6"8"6'-6"WINDOW & DOOR SCHEDULE - MAIN LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DR0.31FOYER0.2311DINING ROOM6068 SGD3050 SHKITCHEN10.3172 1/8" X 80"0.320.310.3136 1/4" X 60 1/4"WINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#2W 3050 SH1BEDROOM #10.310.3172 1/8" X 60 1/4"BEDROOM #30.310.3138 1/4" X 83 1/41POWDER3040 SH0.3136 1/4" X 48"0.312W 3050 SH1LIVING ROOM0.310.3172 1/8" X 60 1/4"1LOFT3040 SH0.3136 1/4" X 48"0.311LAUNDRY3040 SH0.3136 1/4" X 48"0.313050 SH1STAIRS0.3136 1/4" X 60 1/4"0.313050 SH1BEDROOM #20.3136 1/4" X 60 1/4"0.316'-6"1ON ALL WALLS & CEILINGGYP. BOARDNOTE: 16" MFD FLOOR TRUSSESINSTALL PER MFRS SPECSAT 24" O.C.MFD TRUSSES W/ WOOD CAP42" HIGH ANGLED WALLDRP BEAM2x6 WALL 35" HIGHCONCSEWERCLEANOUTNOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYSTRUCTURAL AND/OR SITE CONDITIONSPER PLUMBING, ELECTRICAL, MECHANICAL,NOTE:FRAMER TO ROCK , POLY & INSULATEMECH ROOM EXTERIOR WALLS PRIORTO MECH EQUIPMENT BEING INSTALLEDA/C UNITS MAYBE PLACED ONTHE SIDE OF HOMEIF SIDE YARDSETBACKS ALLOWSILLCOCKWHUP HIGHERVTANKLESS2X6CONC 4'-8"2W 3050 SH72 1/8" X 60 1/4"42" HIGHTEMP22'-0"2'-0"5'-0"MFD TRUSSES AT 24" O.C.22x30ATTICACCESS21'-0" CLEAR FRAMINGTOP OF BEAM FLUSH WITH TRUSSESGARAGESLOPE TO DOORS4" CONC FLOOR548 SQ. FT. (INSIDE)TYPICAL 2x6 GARAGE WALLSGIRDER TRUSSPOINT LOAD FROM ABOVE5'-4"40'-0"HD-FLRLFT-RGT DIRECTIONIRRIGATIONSYSTEMPERMIT/CONSTRUCT PLANS17277 DURHAM DRIVELOT 40 BLOCK 6 - BROOKSHIREPLAN OPTIONSLIVING ROOM HD-FLRIRRIGATION SYSTEM5FT GARAGE BUMPOUTPFHPFH(2)7-1/4Versa LamSINGLE TRIMMERS(3) 24" Versa Lam(3)16" Versa Lam5-1/4" x 5-1/4" VERSA-LAM(2)7-1/4 Versa Lam(2)14" Versa Lam(2)7-1/4 Versa Lam(2)7-1/4 Versa Lam 1/4"=1'-0"ELECTRICAL PLAN2ND FLOORThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C5.0XELECTRICAL PLAN1/4"=1'-0"LIVINGROOMGARAGEPORCHSPRINKLERSYSTEMRECEPTACLELGFIWPSLLLLTSHCPBEDRM #3LCA/CAIREXCHGR BEDRM #1BATH #1MECHLSD/CMDSDLLAHUWHF.D.15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEGFILOW VOLTAGESYSTEM RECEPTACLEFUTURE WATERSOFT OUTLETCL6'-0"3'-10"3'-10"6'-0"SD/CMDWPSPRINKLERSYSTEMRECEPTACLEVENT HOOD TO OUTSIDEPWDRSGFIFANSLSSSDW DISP.SLLLLLLL6'-0"3'-3"3'-3"LLSS LLSSSCHIMESMART HOMERECEPTACLESLAU.FANGFI SS GFI GFISLS FANS W.I.C.LLS LLLSSS DROUGH-INBLANK PLATELSDSDSLS1ST FLOORSWPTO LIGHTFIXT ABOVESSSATTICACCESSSWITCH &LIGHT INATTICBATH#2S LBEDRM #2LOFTLLLLS IRRIGATIONSYSTEMSIENNA x423-GRB ROOF PLN:1-10-23-LLPC#1078: 2-8-23-LLx403 to x423: 3-1-23-LLPERMIT/CONSTRUCT:3-22-23-AFPERMIT/CONSTRUCT PLANS17277 DURHAM DRIVELOT 40 BLOCK 6 - BROOKSHIREPLAN OPTIONSLIVING ROOM HD-FLRIRRIGATION SYSTEM5FT GARAGE BUMPOUT These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C6.0XSIENNA x423-GRB ROOF PLN:1-10-23-LLPC#1078: 2-8-23-LLx403 to x423: 3-1-23-LLPERMIT/CONSTRUCT:3-22-23-AF1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL4" CONC. GAR. FLOOR5/8" GYP. BD.SECTION1/2"=1'-0"9'-1 1/8"VARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R C H U T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806TREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)TREATEDSILL PLATEW/ FOAM SILL SEALMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL(6" CURB, 2" INT. LEDGE)8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.FLOOR TRUSSES PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIAPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)GYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANTAPPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"CONNECTRED TO EACH SIDE OF10' SECTION OF PERFORATED PIPE1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALLR-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20RUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTUREVERTICAL REINFORCINGAS SOIL COND. REQUIRE(SEE HANSON ENGINEERING)"T" FITTING IN AGGREGATE1/2"=1'-0"GARAGE SLAB LEDGE DETAIL4" 8"1/4"=1'-0"CROSS SECTION D-DPWDR1/4"=1'-0"CROSS SECTION B-B3 1/2" CONC. FLOOR3/4" SUBFLOOR14" FLOOR TRUSSES1'-0"7 5/16"5123'-6"KITCHEN9'-1 1/8"GARAGE4" CONC. FLOOR17'-0"17'-0"1/4"=1'-0"CROSS SECTION A-AMFD TRUSS8'-1 1/8"34'-0"3/4" SUBFLOORBEDRM #33'-6"LAUNDRY18'-5"3 1/2" CONC. FLOOR3'-6"3/4" SUBFLOOR16" MFD FLOOR TRUSSESFOYERHAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATABEDRM #3LOFT5'-3"25'-7"1/4"=1'-0"CROSS SECTION D-D1/2"=1'-0"OVER UNCONDITIONED SPACEFLOOR DETAILLIVABLE SPACEGARAGER-30 BATT INSULATION3/4" SUBFLOOR6" ROUND DUCTWORKFLOOR TRUSSESR-8 INSULATION WRAP5/8" TYPE 'X' GYP. BD.16"SPRAY FOAM INSUL.AROUND DUCTWORKCLOSED CELL1" CLOSED CELLSPRAY FOAM512COVEREDCONC. STOOP12429'-0"BEDRM #2BATH #235'-0"9'-5"9'-1 1/8" 8'-1 1/8"20'-6"2X10 LANDINGGARAGE4'-11 3/4"4'-4 1/8"TALL WALL7'-3 1/2"6'-6 1/2"2X10 LANDING2X10 LANDING4'-4 1/8"4'-11 3/4"14" MFD FLOOR TRUSSESBEDRM #1LIVING RM7 3/16"HEEL1'-0"4126'-0"TYPICAL WALLWIP3/4" SUBFLOOR16" MFD FLOOR TRUSSES#39'-1 1/8"GARAGEBEDRM1/4"=1'-0"CROSS SECTION C2-C2OPT 5 FT BOLT-ONGARAGE4" CONC. FLOOR22'-0"4121'-0"7 3/16" 9'-1 1/8"1'-0"1'-0"7 5/16"5121'-0"7 5/16"5'-4"DROPPED BEAM16" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZE5'-4"1248 13/16"HEEL1'-8"8"5'-6"3PLY 16" LVL3PLY 18" LVL14" MFD FLOOR TRUSSES9'-1 1/8"HOUSE/GARAGE COMMON WALL HEIGHT 16" MFD FLOOR TRUSSES9'-1 1/8" GARAGE WALL HEIGHT 2" 9'-1 1/8"MID-CHORD BEARINGON THIS ENDPERMIT/CONSTRUCT PLANS17277 DURHAM DRIVELOT 40 BLOCK 6 - BROOKSHIRE FOUNDATION DETAILAT FOOTING STEP LOCATIONS1S1DescriptionDateRevisionProject Number:Date:S11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20233.0011-1-232023 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2S1WALL SECTIONLOOKOUT WALL CONDITION3S1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4S1WALL SECTIONFULL HEIGHT WALL CONDITION5S1REBAR TABLE6S1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2023©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS: F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE: SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE 1,500 PSF MINIMUMGENERAL NOTES1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3. 112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOILPRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THERESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGNFOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW ANDCONSENT OF THE HANSON GROUP.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2023.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/S1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/S2FLOOR TO SILLCONNECTION SEE 1/S2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4 x 5'-0" HOOKS @ 24" O.C.EMBEDDED IN FOUNDATIONWALL & CAST INTO SLAB(MAY REDUCE 2'-0" LEG LENGTH& DRILL IN & EPOXY 8" MIN.INTO FOUNDATION WALL)3'-0"NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)2'-0"8'-0" OR LESS9'-0" MAX.10'-0" MAX.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2023©DescriptionDateRevisionJanuary 1, 2023Project Number:Date:3.001S22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2346665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1S2BRICK LEDGE INFO5S2WALL SECTIONAT WINDOW WELL LOCATIONS6S2STOOP INFO7S2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2S2BLOCKING DETAILFLOOR JOIST CONDITION3S2BLOCKING DETAILFLOOR TRUSS CONDITION4S2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/S1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/S1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/S1 OR 3/S1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/S1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/S2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/S1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)FLOOR MEMBERSPACING16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/ASLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.* FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERNAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/S1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/S1LOOKOUTWALLSEE 3/S1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.BACKFILL HEIGHT (NOT TO EXCEED 10'-0")SEE 5/S1 FOR TYPICALFOUNDATION WALL &FOOTING CONSTRUCTIONMAINTAIN MIN. 6" WIDESTEMWALL WITHEXTERIOR LEDGEWOOD FLOORSYSTEM BY OTHERSBACKFILL BELOW EXTERIORSTOOP SLABS WITH COMPACTEDGRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM)FLASHING &WATERPROOFINGBY OTHERSSTOOP SLAB BY OTHERS* SEE 1/S2 FOR FLOORTO SILL CONNECTION112" CLEARBUILD UP w/ RIGIDINSULATION BELOW SLABTO MAINTAIN 10'-0" MAX.BACKFILL HEIGHT ASREQ'D OR PROVIDE SITESPECIFIC ENGINEERING(MAY SUBTRACT 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY & CLAY SOILS DUE TO GRANULAR FILL BELOW STOOP SLAB) * MODIFIED CLEAR HEIGHT* SEE REBAR TABLE 6/S1FOR VERTICAL REBAR* SEE 2/S2 FOR ANCHOR BOLTS* FOR REBAR TABLE 6/S1, FLOOR TO SILL CONNECTION TABLE 1/S2, AND ANCHOR BOLT TABLE 2/S2USE MODIFIED CLEAR HEIGHT OF 9'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 8'-6" ANDUSE MODIFIED CLEAR HEIGHT OF 10'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 9'-6"(MAY REDUCE BACKFILL HEIGHT BY 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY AND CLAY SOILS)8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 (4-FT)(4-FT)BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINE(4.9-FT)COPYRIGHT HANSON GROUP, LLC 2022©MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTDescriptionDecember 9, 2022Project Number:Date:2.592S11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044X403/X423D-GR ModelMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Garrett Brunell12-9-2252600Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUTFOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUTFOUNDATIONSMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ONLY w/ OPTIONAL UPPER LEVEL)3S1REFERENCE PLANSCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THE STRUCTURE AND ISEXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS.CONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION5S1FRAMING DETAIL(4-FT)(4-FT)(4-FT)(4-FT)(4-FT) BRACED WALL LINE BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINE(4-FT)(3-FT)(4-FT)(4-FT)(4-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINECONSTRUCTPORTAL FRAMEAS SHOWN IN 4/S1WITH GARAGE SIDE 5FT BUMP-OUT OPTION(2.4-FT)THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATE w/(3) 16d NAILS EVERY 16"(OR AS SHOWN TOTHE RIGHT IF REQ'D)FASTEN PLATE w/ 14"CONCRETE SCREWS ORPOWDER ACTUATED 0.145"WASHERED PINS @ 16" O.C.w/ 1" EMBEDMENT INCONCRETEWITH 3RD STALL GARAGE OPTION(4.2-FT)(4-FT) BRACED WALL LINE(5-FT)(5-FT) (8-FT)BRACED WALL LINE BRACED WALL LINE (5-FT)(5-FT) BRACED WALL LINE(6-FT) (4-FT) BRACED WALL LINE (4-FT)(3-FT)(4-FT)BRACEDWALL LINE(5-FT)(4-FT)(5-FT)(6-FT)(4-FT)(4-FT)(4-FT)BRACED WALL LINE (4-FT) BRACED WALL LINES1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 5/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS2'-412"±2'-412"± 1 ST011 ST02KS01JS01CS01CS02CS03CS04CS05CS06CS03CS07CS02CS08JS02KS02ST03ST04H01 H02 ST0507-03-0818-05-002 Page 1 of 3 Wall Summary Information W01-Stairway BC CALC®Member Report Wall |07-03-08 |12 OCS November 30,2022 11:44:27 Build 8381 Job name:MN X403 File name:MN X403 -Tall wall Address:Description: City,State,Zip:Specifier:Plan Builder:D R Horton Designer:PG Code reports:ESR-1040 Company:Boise Cascade X423 SLAB Page 2 of 3 Wall Summary Information W01-Stairway BC CALC®Member Report Wall |07-03-08 |12 OCS November 30,2022 11:44:27 Build 8381 Job name:MN X403 File name:MN X403 -Tall wall Address:Description: City,State,Zip:Specifier:Plan Builder:D R Horton Designer:PG Code reports:ESR-1040 Company:Boise Cascade Load Summary Live Dead Snow Wind Roof Live Tributary Tag Description Load Type Ref.Start End 100%90%115%160%125% 1 Wind Unf.Area (lb/ft²)L 00-00-00 18-05-00 20 01-00-00 2 Roof Load Unf.Lin.(lb/ft)L 00-00-00 07-03-08 100 175 01-00-00 Bearing Supports Size Value %Allowable Duration Material Top Plate Double 2x 517 lbs 14.7%115%Spruce-Pine-Fir Bottom Plate 2x 517 lbs 14.7%115%Spruce-Pine-Fir OpeningsTagDescription Distance Ref.Elevation Ref.Height Width Justification 1 03-07-12 Left 08-09-10 Bottom 60"36"Bottom/Middle Critical Member SummaryTagProduct Plies Results Connection ST01 1-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 1 Passed 2-8d box toe-nails KS01 1-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 2 Passed 2-16d common toe-nails KS02 1-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 2 Passed 2-16d common toe-nails H01 3-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 1 Passed 2-8d box toe-nails H02 Plank 2 x 6 SPF #2 1 Passed 2-16d box end-nails Wall Framing Net Tag Qty Product Plies Length Connection ST01,ST02,S...,ST04,ST05 5 1-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 1 20-00-00 2-8d box toe-nails KS01,KS02 4 1-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 2 20-00-00 2-16d common toe-nails JS01,JS02 2 2 x 6 SPF #2 1 14-00-00 CS01,CS04,...,CS07,CS08 5 2 x 6 SPF #2 1 04-00-00 CS02,CS03,CS05 5 2 x 6 SPF #2 1 10-00-00 2-8d box toe-nails,* H01 1 3-1/2"x 5-1/2"VERSA-LAM®LVL 1.8E 2650 SP 1 04-00-00 2-8d box toe-nails H02 1 2 x 6 SPF #2 1 04-00-00 2-16d box end-nails BP01 1 1-1/2"x 5-1/2"Spruce-Pine-Fir 1 08-00-00 TP01 2 1-1/2"x 5-1/2"Spruce-Pine-Fir 2 08-00-00 Fire blocking is not included.Estimated quantity:15'fire blocking. *Another connection exists,please review the individual member's report. Notes BC CALC®considers gravity and out-of-plane lateral loading only.Wall bracing (braced wall panels)to resist in-plane lateral loading (parallel to wall)is the responsibility of the building designer. Lateral Deflection:User specified (L/180)Total load lateral deflection criteria Vertical Deflection:User specified (L/240)Total load deflection criteria Vertical Deflection:User specified (L/360)Live load deflection criteria Vertical Deflection:Arbitrary (1")Total load deflection criteria BC CALC®analysis is based on IBC 2018. Page 3 of 3 Wall Summary Information W01-Stairway BC CALC®Member Report Wall |07-03-08 |12 OCS November 30,2022 11:44:27 Build 8381 Job name:MN X403 File name:MN X403 -Tall wall Address:Description: City,State,Zip:Specifier:Plan Builder:D R Horton Designer:PG Code reports:ESR-1040 Company:Boise Cascade DisclosureUseoftheBoise Cascade Software is subject to the terms of the End User License Agreement (EULA).Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods.Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJS™,ALLJOIST®,BC RIM BOARD™,BCI®,BOISE GLULAM™,BC FloorValue®,VERSA-LAM®,VERSA-RIM PLUS®, VERSA-RIM®,VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-10 X R-10 X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X Not applicable, all ducts located in conditioned space R8 Not required per mech. code X Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60,000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's 6 " round duct OR 5 " metal duct X Not required per mech. code Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct THERMAL ENVELOPE Foam Open Cell Wall Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.31 Appliances Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM R10 ExteriorNon or Not Applicable Cooling System Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor Silver Tree Plumbing and Heating MN License Number 17277 Durham Drive MB005441 City Mailing Address of the Dwelling or Dwelling Unit Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 41,552 Heating Gain Cooling Load 48 97 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation Heating Loss Combustion Air Select a Type Location of duct or system: 18,564Total R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.30 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) Sensei160 BA13NA024 Model Heating System Nat Gas Bryant Interior Interior Mech Room 6" Flex Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type Rinnai Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13SEER /EER 912SD Manufacturer Bryant Nat Gas Output in Tons:2Tankless Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM 288 48 Capacity continuous ventilation rate in cfms: powder, main, master Builders Associaton of Minnesota version 101014 3 4 X 15 =601842 1842 X 0.02 =36.84 Continuous Ventilation Requirement = Enter # of Bedrooms Ventilation 96.84 48.42 Sq Ft of Home (including unfinished basements etc) Total Ventilation Requirement = Step 1: Draft Hood Fan Assisted 60000 Direct Vent Input:60000 Btu/hr & Power vent Draft Hood Fan Assisted 160,000 Direct Vent Input:160000 Btu/hr & Power vent Step 2: 418 ft^3 Step 3: Step 4:4a. Input:0 Btu/hr TRV:0 ft^3 4b. Input:0 Btu/hr RVFA:0 ft^3 Input:0 Btu/hr RVNFA:ft^3 TRV =0 +0 =0 ft^3 Ratio =418 /0 =#DIV/0! RF=1 -#DIV/0!= Input:0 Btu/hr CAOA=0 /3000 Btu/hr per in2 =0 in2 0 x #DIV/0!=#DIV/0!in2 CAOD =1.13 x #DIV/0!=#DIV/0!inCAOD = 1.13 multiplied by the square root of Minimum CAOA 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = Step 9: Calculate Combustion Air Opening Diameter (CAOD) #DIV/0! Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Total Btu/hr divided by 3000 Btu/hr per in^2 Use Non-Fan-Assisted Appliances column in Table E-1 to find Combustion Air Opening Area (CAOA): Step 5: Calculate the ratio of available interior volume to the total required volume. Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Total Required Volume (TRV) = RVFA + RVNFA Required Volume Non-Fan-Assisted (RVNFA) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Determine air Changes per Hour (ACH)1Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. Determine Required Volume for Combustion Air.Standard Method Use Fan-Assisted Appliances column in Table E-1 to find Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) The CAS includes all spaces connected to one another by code compliant openings.CAS Volume: Furnace/Boiler: Water Heater:(Not fan assisted) (Not fan Assisted) Required Volume Fan Assisted (RVFA) Complete vented combustion appliance information: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) 1346.6012 IFGC APPENDIX E, WORKSHEET E-1. Total Btu/hr input of all non-fan-assisted appliances If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Known Air Infiltration Rate (KAIR) MethodTotal Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) 1994(1) to Present Pre 1994(2)1994(1) to Present Pre 1994(2) 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,05025,000 1,250 1,875 938 2,625 1,31330,000 1,500 2,250 1,125 3,150 1,57535,000 1,750 2,625 1,313 3,675 1,83840,000 2,000 3,000 1,500 4,200 2,10045,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,15065,000 3,250 4,875 2,438 6,825 3,41370,000 3,500 5,250 2,625 7,350 3,67575,000 3,750 5,625 2,813 7,875 3,93880,000 4,000 6,000 3,000 8,400 4,20085,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250105,000 5,250 7,875 3,938 11,025 5,513110,000 5,500 8,250 4,125 11,550 5,775115,000 5,750 8,625 4,313 12,075 6,038120,000 6,000 9,000 4,500 12,600 6,300125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613150,000 7,500 11,250 5,625 15,750 7,875155,000 7,750 11,625 5,813 16,275 8,138160,000 8,000 12,000 6,000 16,800 8,400165,000 8,250 12,375 6,188 17,325 8,663170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713190,000 9,500 14,250 7,125 19,950 9,975195,000 9,750 14,625 7,313 20,475 10,238200,000 10,000 15,000 7,500 21,000 10,500205,000 10,250 15,375 7,688 21,525 10,763210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813230,000 11,500 17,250 8,625 24,150 12,075(1)The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH.(2)This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. 1346.6014 IFGC APPENDIX E, TABLE E-1. Known Air Infiltration Rate (KAIR) Method (ft3) Fan Assisted Non-Fan-Assisted IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Standard Method (ft3) Input Rating (Btu/hr) One or multiple power vent or direct vent appliances or no combustion appliancesA One or multiple fan-assisted appliances and power vent or direct vent appliancesB One atmospherically vented gas or oil appliance or one solid fuel applianceC Multiple atmospherically vented gas or oil appliances or solid fuel appliancesD 1a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 1842 0 0 0Estimated House Infiltration (cfm): [1a x 1b] 276.3 0 0 0 2.a) Exhaust Capacity continuous exhaust-only ventilation systems (cfm): (not applicable to balanced ventilation systems such as HRV) 0 0 0 0 b) clothes dryer 135 135 135 135 c) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 240 0 240 240 d) 80% of next largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 0 0 0 Total Exhaust Capacity (cfm): [2a+2b+2c+2d] 375 135 375 375 3.a) Makeup Air Requirement Total Exhaust Capacity (from above) 375 135 375 375 b) Estimated House Infiltration (from above) 276.3 0 0 0 Makeup Air Quantity (cfm): [3a – 3b] (if value is negative, no makeup air is needed) 98.7 135 375 375 4. For Makeup Air Opening Sizing, refer to Table 501.3.2 One or multiple power vent or direct vent appliances or no combustion appliancesA One or multiple fan-assisted appliances and power vent or direct vent appliancesB One atmospherically vented gas or oil appliance or one solid fuel applianceC Multiple atmospherically vented gas or oil appliances or solid fuel appliancesD Passive makeup air opening duct diameterE,F,G Type of opening or system (cfm) (cfm) (cfm) (cfm) (inches) Passive Opening 1-36 1-22 1-15 1-9 3Passive Opening 37-66 23-41 16-28 10-17 4 Passive Opening 67-109 42-66 29-46 18-28 5Passive Opening 110-163 67-100 47-69 29-42 6Passive Opening 164-232 101-143 70-99 43-61 7Passive Opening 233-317 144-195 100-135 62-83 8Passive Opening with Motorized Damper 318-419 196-258 136-179 84-110 9Passive Opening with Motorized Damper 420-539 259-332 180-230 111-142 10Passive Opening with Motorized Damper 540-679 333-419 231-290 143-179 11Powered Makeup AirH >679 >419 >290 >179 not applicable G Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.H Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.3.2 Makeup Air Opening Sizing Table for New and Existing Dwellings C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmosphericallyvented gas or oil appliances and solid fuel appliance(s). E An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustionappliances. B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. Table 501.3.1 Procedure to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings Use the Appropriate Column to Estimate House Infiltration A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-24 14:35:31Right-Suite® Universal 2022 22.0.01 RSU64702 Page 1 ...\Documents\Wrightsoft HVAC\DRH- X423- Siena.rup Calc = MJ8 Front Door faces: E Job:Load Short Form 1/10/23Date:Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silvertreepandh.com Web: www.silvertreepandh.com Project Information DRH- X423- SienaFor: Design Information InfiltrationClgHtg SimplifiedMethod88-15Outside db (°F)Semi-tightConstruction quality7270Inside db (°F) 1 (Semi-tight)Fireplaces1685Design TD (°F) M-Daily range 5030Inside humidity (%)5030Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Generic Make Generic Trade TradeModelAFUE 92 Cond SEER 13.0 AHRI ref Coil AHRI refEfficiency92 AFUE Efficiency 11.6 EER, 13 SEER Heating input Btuh45166 Sensible cooling Btuh15833 Heating output Btuh41552 Latent cooling Btuh6786 Temperature rise °F52 Total cooling Btuh22619 Actual air flow cfm754 Actual air flow cfm754 Air flow factor cfm/Btuh0.019 Air flow factor cfm/Btuh0.044 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.86 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room2 756 19537 9906 372 438 Room4 756 11856 4633 226 205 Room5 330 8167 2522 156 111 Entire House 1842 39561 17062 754 754 Other equip loads 1992 0 Equip. @ 0.93 RSM 15833Latent cooling 2731 TOTALS 1842 41552 18564 754 754 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Alexis Flores 3/23/23 X PM