Loading...
HomeMy WebLinkAboutLA212011 - 5759 Upper 179th St W - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode05/09/2023dmathews UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. BWPsAbove7566PFHPFHHold-downHold-down62.53.752.752.252.75 -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.332.53Connections $4#%'&9#..2#0'.(#56'0$1661/2.#6'61,1+56$.1%-+0)Y  F0#+.5'8'4;1%%#06+.'8'4'&(.114,1+56$;5722.+'4(4#/'9#..$4#%'&9#..2#0'.$'.19$.1%-+0)$'69''0,1+565#5(1..195x(.#6Z612 $1661/14,1+56/#6'4+#.145#90$.1%-+0)x2.;911&5*''60#+.'&61ZžUY  F0#+.5612 $1661/x%+4%7.#4*1.'7261Œ/#;$'%76+061%'06'41(2.;911&0#+.(.1145*'#6*+0)61$.1%-+0)YF0#+.5"1%(#56'0$1661/ZY  F0#+.5'8'4;1%5'%6+105#6$4#%'&9#..2#0'.5#$18'%#06+.'8'4'&(.114(4#/+0) 4'('4612.#05(14#22.+%#$.'.1%#6+105 ‹&GUETKRVKQP&CVG4GXKUKQP#RTKN2TQLGEV0WODGT&CVG55JGGVUQH2TKPV0COG5KIPGF.KEGPUG0WODGTÄÄ&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC-G[.CPF*QOGU(KUJ2QKPV4F5'2TKQT.CMG/0%GFCT.CMG4QCF5WKVG5V.QWKU2CTM/06GNÄÄYYYJCPUQPITQWROPEQO2.#055*190.+)*6+0$#%-)4170&#4'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)4172ž5&'5+)0%12;4+)*6*#0510)4172..%6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'/#+09+0&(14%'4'5+56+0)5;56'/(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)4172ž5&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&#4&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;176411(64755'5$4#%'&9#..2#0'.(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. 5+/2510#(4#/+0)#0).''#%*'0&  ŒZ0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565$4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10 411(64755'5 (.114,1+565 (.11464755'5 &'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19 144'2.#%'Y#&'37#6'&'26*Z/'/$'4 Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; ':6'4+14$'#4+0)9#..4'24'5'065(+)74'4  +0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'&#61%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'&#55*190+06*'&'6#+.5*''65 /+0.'0)6* +0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19 /+0.'0)6* Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'55%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14&#0%'9+6*6*+5&1%7/'0656#0&#4&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952#0&%5Ä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ŒZ61'0#+.5%411(5*'#6*+0)5647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)#.10).'0)6*1(9#..5.#29#..6122.#6'5#/+0+/7/1(#0&(#56'061)'6*'49+6*  ŒZ+0.#2<10'#6%140'45#0&+06'45'%6+105.#22.#6'5#0&2418+&'  ŒZ(#%'0#+.5%100'%6+10501652'%+(+%#..;016'&#4'61$'+0#%%14&#0%'9+6*%1&'6#$.'4  6#..911&9#..(4#/+0)+561$'&'5+)0'&$;5722.+'4(14)4#8+6;#0&176Ä1(Ä2.#0'9+0&.1#&56*''064;214%*+5%105+&'4'&61$'#24+/#4+.;12'0010Ä'55'06+#.2146+101(6*'5647%674'#0&+5':%.7&'&(41/6*'18'4#../#+09+0&(14%'5;56'/1(6*'*1/'2418+&'%1&'4'37+4'&72.+(6%100'%6+105#6#..21565/#6'4+#.59#..567&5 ž14.'55 52(567&)4#&'14$'66'49#..567&5 18'4ž 52(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*7.6+/#6'':2$%1&'/+00'516#4'5+&'06+#.%1&'411(64755'5(#56'0'&612.#6'5Y  ŒZ61'0#+.5 5+/2510*%.+20#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+.$1661/2.#6'614+$$10$4#%'64755Y  F0#+.5'8'4;0#+.'#%*,1+56616122.#6'5Y  ŒZ0#+.5Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  ŒZ0#+.5'#%*0#+.'#%*64755616122.#6'5Y  ŒZ61'0#+.5411(64755(#56'0'&612.#6'5YŒZ61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+.4+/6122.#6'5YŒZ61'0#+.5"1%0#+.$1661/2.#6'61.#&&'464755Y  F0#+.5'8'4;0#+..#&&'464755616122.#6'5YŒZ0#+.5"1%+06'4+149#..2'42'0&+%7.#461(4#/+0)+06'4+149#..2#4#..'.Y(4#/+0)Z$.1%-+0)$'69''0411(64755'50#+.'&616122.#6'5Y  ŒZ0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y  ŒZ0#+.5'#%*0#+.'#%*,1+56616122.#6'Y  ŒZ0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  ŒZ0#+.5'#%*0#+.'#%*64755616122.#6'Y  ŒZ61'0#+.52418+&'411(64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YŒZ61'0#+.5"1%0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YŒZ61'0#+.5"1%0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YŒZ61'0#+.5"1%2NCP/KPPGUQVC%QPUVTWEVKQP2156Ä+056#..'&*1.&190126+105(4#/+0)&'6#+.722'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.; #%67#..#;176/#;$'/+4414'& 54'('4'0%'2.#02#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.; #%67#..#;176/#;$'/+4414'& 54'('4'0%'2.#0/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.; #%67#..#;176/#;$'/+4414'& 54'('4'0%'2.#05(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.70.'55016'&16*'49+5'%105647%62146#.(4#/'#55*190+05/+4414'& 5+/ žÄ(#56'06122.#6'61*'#&'4Y  4195F5+0-'40#+.5"1%  Z$'#4+0)567&   Z(7..*'+)*6-+0)567&#6'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0žÄ(41/%'06'41(*'#&'4*'+)*6#54'3ž& Z51.+&$.1%-+0)4'37+4'&#65*'#6*+0),1+06  Z$'#4+0)567&5/+0 8'4+(;Y5722.+'4 5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190 4'('4615(14#.6'40#6+8'126+10 (170&#6+109#..$'.19.'0)6*1(%106+07175*'#&'4  Œ#0%*14$1.65 /+0'/$'& YZZ2.#6'9#5*'450#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5 0#+.5*'#6*+0)#4170&2'4+/'6'4Y  4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1% 5+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55 (#56'0-+0)567&61*'#&'4Y  4195F5+0-'40#+.5"1%6;2žÄ%106+07175.5..8.*'#&'46157221468'46+%#..1#&5$;5722.+'4 /+09+&6* /+0&'26*4'3ž& 2418+&'Z+0(+..9#..#$18'*'#&'4#54'3ž&.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&#4&0#+.+0)2418+&'(#56'0+0)1(#$18'(4#/+0)#55*190(14$4#%'&9#..2#0'.55+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55  Z$'#4+0)567&   Z(7..*'+)*6-+0)567&5#6'0&1(*'#&'4%10%4'6'(170&#6+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*190YŒZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*14%105647%62146#.(4#/'#55*190+0501661':%''&žÄ0KEM*CPUQPžÄ"5+/$4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'& 9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 2418+&'612 $1661/1(9#..%100'%6+1055*190(14$4#%'&9#..2#0'.5#.10)+0&+%#6'&2146+101(9#.. Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 10'5+&'&10'5+&'& Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'&9#...+0'$4#%'& 9#...+0' $4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 H2H1C1C2B4B3B3B3B3B3B3B3B3B3B3B3B1B1B1B1B1B2V1V2V3V4V5V7V8P11P138-00-004-00-002-00-0032-00-0038-00-0014-06-00 9-06-00 10-00-0034-00-0034-00-00Customer: Key Land HomesJob Number: 323761-AHome Owner: 2671 A-SPECJob Name: RoofSite Address: 5759 UPPER 179TH STREET Sales Rep: John FrankCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Unassigned2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/10/2023Version: 8.5.3.233 F1F1F1F1F1F1F1F1A2A1A1A1A1A1A1A1N1N1N1N1N1N1N1N1N2O1O2O2O2O2O3O3O3O3O3V6V922-00-0024-00-0046-00-006-00-0032-00-008-00-0046-00-0030-06-0019-06-0050-00-0032-00-0018-00-0050-00-00Customer: Key Land HomesJob Number: 323761-AHome Owner: 2671 A-SPECJob Name: RoofSite Address: 5759 UPPER 179TH STREET Sales Rep: John FrankCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Unassigned2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/10/2023Version: 8.5.3.233 Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 TOTAL INPUT OF APPLIANCES1, THOUSANDS OF Btu/hr (kW) REQUIRED FREE AREA OF AIR-SUPPLY OPENING OR DUCT, SQUARE INCHES (sq mm) ACCEPTABLE APPROXIMATE ROUND DUCT EQUIVALENT DIAMETER2, INCH (mm) 25 (8)7 (4,500)3 (75) 50 (15)7 (4,500)3 (75) 75(23)11 (7,000)4 (100) 100 (30)14 (9,000)4 (100) 125 (37)18 (12,000)5 (125) 150 (45)22 (14,000)5 (125) 175 (53)25 (16,000)6 (150) 200 (60)29 (19,000)6 (150) 225 (68)32 (21,000)6 (150) 250 (75)36 (23,000)7 (175) 275 (83)40 (26,000)7 (175) 300 (90)43 (28,000)7 (175) 325 (98)47 (30,000)8 (200) 350 (105)50 (32,000)8 (200) 375 (113)54 (35,000)8 (200) 400 (120)58 (37,000)9 (225) 1. For total inputs falling between listed capacities, use next largest listed input. 2. If flexible duct is used, increase the duct diameter by one inch. * *Flexible duct shall be stretched with minimal sags. TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING 400,000 Btu/hr BTU Amount for Non-direct vent appliances_____________________ 1 2 3 4 5 6 2 Conditioned space1 (in sq. ft.) Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130-65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113 1. Conditioned space includes the basement and conditioned crawl spaces. 2. If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation R403.5.2 R403.5.2 Total Ventilation rate. The mechanical ventilation system shall rovide sufficient outdoor air to equal the total ventilation rate average for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and square footage of conditioned space, including the basement and conditioned crawl spaces. For the purposes of Table R403.5.2 and Section R403.5.3, the following applies: a. Equation R403.5.2 Total ventilation rate: Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms +1)) b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventiation rate/2 Amount Total _________________________ Amount Continuous____________________ TABLE R403.5.2 NUMBER OF BEDROOMS VENTILATION REQUIREMENTS ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD 1. Use the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) b) conditioned floor area (sf) (including unfinished basements) Estimated House Infiltration (cfm): [1a x 1b] 2. Exhaust Capacity a) clothes dryer b) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) c) 80% of next largest exhaust rating (cfm):not applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm): [2a+2b+2c] 3. Makeup Air Requirement a) Total Exhaust Capacity (from above) b) Estimated House Infiltration (from above) Makeup Air Quality (cfm): [3a - 3b] (if value is negative, no makeup air is needed 4. For Makeup Air Opening Sizing, refer to Table 501.4.2. A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Table 501.4.1 Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units Choose Which Applies TYPE OF OPENING ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD PASSIVE MAKEUP AIR OPENING DUCT DIAMETERE,F,G OR SYSTEM (cfm)(cfm)(cfm)(cfm)(inches) Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 144-195 100-135 62-83 8 Passive opening with motorized damper 318-419 196-258 136-179 84-110 9 Passive opening with motorized damper 420-539 259-332 180-230 111-142 10 Passive opening with motorized damper 540-679 333-419 231-290 143-179 11 Powered makeup airH >679 >419 >290 >179 Not applicable A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (ther than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combution appliace information: Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: Btu/hr (Not fan Assisted) & Power Vent Water Heater: Draft Hood Fan Assisted Direct Vent Input: Btu/hr ( Not fan Assisted) & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 Step 3: Determine air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) RVFA: ft3 Total Btu/hr input of all non-fan-assisted appliances Input: Btu/hr Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) RVNFA: ft3 Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio RF = - = Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 / Btu/hr per in 2 = in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 x Minimum CAOA = in 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. CAOA = IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Known Air Infiltration Rate (KAIR) Method (ft3) Input Rating Standard Method Fan Assisted Non-Fan-Assisted (Btu/hr) (ft3) 19941 to Present Pre 19942 19941 to Present Pre 19942 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8,625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,763 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. West Metro Mechanical HVAC Load Calculations for 5759 Upper 179th Street Lakeville, MN Prepared By: Tuesday, April 11, 2023 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 2 Project Report General Project Information Project Title:West Metro Mechanical Project Date:Tuesday, April 11, 2023 Client Address:5759 Upper 179th Street Client City:Lakeville, MN Client Comment:Lot 15, Block 2 - Knob Hill of Lakeviille Third Addition Design Data Reference City:Minneapolis/St. Paul AP, Minnesota Building Orientation:Front door faces South Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15 n/a n/a 72 n/a Summer:88 71 44%50%75 24 Check Figures Total Building Supply CFM:869 CFM Per Square ft.:0.220 Square ft. of Room Area:3,944 Square ft. Per Ton:1,878 Volume (ft³):27,600 Building Loads Total Heating Required Including Ventilation Air:64,810 Btuh 64.810 MBH Total Sensible Gain:19,581 Btuh 78 % Total Latent Gain:5,626 Btuh 22 % Total Cooling Required Including Ventilation Air:25,206 Btuh 2.10 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 3 Miscellaneous Report System 1 House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15 100%n/a 72 n/a Summer:88 71 44%50%75 23.51 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:Yes Yes Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:0 ft./min 0 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:0 in.0 in. Maximum Height:0 in.0 in. Outside Air Data Winter Summer Infiltration Specified:0.370 AC/hr 0.190 AC/hr 170 CFM 87 CFM Infiltration Actual:0.370 AC/hr 0.190 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 27,600 X 27,600 10,212 Cu.ft./hr 5,244 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:170 CFM 87 CFM Total Building Ventilation:185 CFM 185 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.370 AC/hr (170 CFM), Construction: Average Summer Infiltration Specified:0.190 AC/hr (87 CFM), Construction: Average C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 4 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.10 1,878 3,944 19,581 5,626 25,206 64,810 776 869 869 System 1 2.10 1,878 3,944 19,581 5,626 25,206 64,810 776 869 869 10x16 Ventilation 1,027 2,870 3,896 6,871 Zone 1 3,944 18,554 2,756 21,310 57,939 776 869 869 10x16 1-Basement 1,376 2,918 427 3,345 15,819 212 137 137 2--6 2-First Floor 1,376 7,650 827 8,477 22,883 306 358 358 4--6 3-Second Floor 1,192 7,986 1,502 9,488 19,237 257 374 374 4--6 C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 5 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Basement Built-In 0 750 0.01 0.1 348.1 212 137 137 2--6 2-First Floor Built-In 0 750 0.01 0.1 456.3 306 358 358 4--6 3-Second Floor Built-In 0 750 0.01 0.1 476.4 257 374 374 4--6 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 782.3 776 869 869 10x16 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:776 Cooling Flow:869 C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 6 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Marvin: Glazing-Custom Window, U-value 0.3, SHGC 0.34 110 2,871 0 1,543 1,543 Marvin: Glazing-Custom Window, U-value 0.28, SHGC 0.34 138 3,361 0 1,391 1,391 Marvin: Glazing-Custom Window, U-value 0.3, SHGC 0.33 96 2,507 0 1,976 1,976 Marvin: Glazing-Custom Window, U-value 0.38, SHGC 0.37 24 793 0 287 287 Marvin: Glazing-Custom Window, U-value 0.28, SHGC 0.37 56.2 1,368 0 1,720 1,720 Marvin: Glazing-Custom Window, U-value 0.3, SHGC 0.3 30 783 0 527 527 Marvin: Glazing-Custom Window, U-value 0.37, SHGC 0.28 6 193 0 61 61 11P: Door-Metal - Polyurethane Core, U-value 0.29 45 1,136 0 313 313 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 846 3,948 0 73 73 15B0-10sf-4: Wall-Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 280 1,316 0 0 0 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2904.8 16,427 0 2,512 2,512 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 1704 2,965 0 1,636 1,636 21B-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.019 1376 2,275 0 0 0 22D-10pm: Floor-Slab on grade, Vertical board insulation covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 40 1,194 0 0 0 20P-30: Floor-Over open crawl space or garage, Passive, R-30 blanket insulation, any cover, U-value 0.035 328 999 0 92 92 Subtotals for structure:42,136 0 12,131 12,131 People:7 1,400 1,610 3,010 Equipment:0 3,600 3,600 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 170, Summer CFM: 87 15,803 1,356 1,213 2,569 Ventilation: Winter CFM: 185, Summer CFM: 185 6,871 2,870 1,027 3,896 Exhaust: Winter CFM: 185, Summer CFM: 185 Total Building Load Totals:64,810 5,626 19,581 25,206 Check Figures Total Building Supply CFM:869 CFM Per Square ft.:0.220 Square ft. of Room Area:3,944 Square ft. Per Ton:1,878 Volume (ft³):27,600 Building Loads Total Heating Required Including Ventilation Air:64,810 Btuh 64.810 MBH Total Sensible Gain:19,581 Btuh 78 % Total Latent Gain:5,626 Btuh 22 % Total Cooling Required Including Ventilation Air:25,206 Btuh 2.10 Tons (Based On Sensible + Latent) Notes C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 7 Total Building Summary Loads (cont'd) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 8 Building Pie Chart Building Loss 64,810 Btuh Floor 7% Roof 5% Wall 33% Glass 18% Door 2% Infiltration 24% Ventilation 11% Building Gain 25,206 Btuh Floor 0%Roof 6% Wall 10% Glass 30% Door 1%People 12% Equipment 14% Infiltration 10% Ventilation 15% C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 9 Detailed Room Loads - Room 1 - Basement (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:34.4 ft.System Number:1 Room Width:40.0 ft.Zone Number:1 Area:1,376.0 sq.ft.Supply Air:137 CFM Ceiling Height:9.0 ft.Supply Air Changes:0.7 AC/hr Volume:12,384 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:2 Actual Winter Vent.:51 CFM Runout Air:68 CFM Percent of Supply.:37 % Runout Duct Size:6 in.Actual Summer Vent.:29 CFM Runout Air Velocity:348 ft./min.Percent of Supply:21 % Runout Air Velocity:348 ft./min.Actual Winter Infil.:29 CFM Actual Loss:0.076 in.wg./100 ft.Actual Summer Infil.:15 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-15B0-10sf-8 50 X 9 450 0.050 4.7 2,100 0.1 0 39 W -Wall-15B0-10sf-8 28 X 9 252 0.050 4.7 1,176 0.1 0 22 W -Wall-15B0-10sf-4 12 X 4 48 0.054 4.7 226 0.0 0 0 W -Wall-12F-0sw 12 X 5 60 0.065 5.7 339 0.9 0 52 N -Wall-15B0-10sf-4 34 X 4 136 0.054 4.7 639 0.0 0 0 N -Wall-12F-0sw 34 X 5 128 0.065 5.7 724 0.9 0 111 N -Wall-12F-0sw 16 X 9 102 0.065 5.7 577 0.9 0 88 E -Wall-15B0-10sf-4 24 X 4 96 0.054 4.7 451 0.0 0 0 E -Wall-12F-0sw 24 X 5 120 0.065 5.7 679 0.9 0 104 E -Wall-15B0-10sf-8 16 X 9 144 0.050 4.7 672 0.1 0 12 N -Gls-Marvin shgc-0.34 100%S (2)42 0.300 26.1 1,096 10.3 0 434 N -Gls-Marvin shgc-0.34 100%S 42 0.280 24.4 1,023 10.1 0 423 Floor-21B-20 40 X 34.4 1376 0.019 1.7 2,275 0.0 0 0 Floor-22D-10pm 40 ft..Per. 40 0.343 29.8 1,194 0.0 0 0 Subtotals for Structure:13,171 0 1,285 Infil.: Win.: 28.5, Sum.: 14.6 587 4.511 2,648 0.346 227 203 People: 200 lat/per, 230 sen/per:1 200 230 Equipment:0 1,200 Room Totals:15,819 427 2,918 C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 10 Detailed Room Loads - Room 2 - First Floor (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:34.4 ft.System Number:1 Room Width:40.0 ft.Zone Number:1 Area:1,376.0 sq.ft.Supply Air:358 CFM Ceiling Height:9.0 ft.Supply Air Changes:1.7 AC/hr Volume:12,384 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:4 Actual Winter Vent.:73 CFM Runout Air:90 CFM Percent of Supply.:20 % Runout Duct Size:6 in.Actual Summer Vent.:76 CFM Runout Air Velocity:456 ft./min.Percent of Supply:21 % Runout Air Velocity:456 ft./min.Actual Winter Infil.:79 CFM Actual Loss:0.130 in.wg./100 ft.Actual Summer Infil.:40 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0sw 50 X 9 375 0.065 5.7 2,121 0.9 0 324 W -Wall-12F-0sw 40 X 9 348 0.065 5.7 1,968 0.9 0 301 N -Wall-12F-0sw 50 X 9 294 0.065 5.7 1,663 0.9 0 254 E -Wall-12F-0sw 40 X 9 330 0.065 5.7 1,866 0.9 0 285 S -Door-11P 3 X 8 24 0.290 25.2 606 7.0 0 167 S -Door-11P 3 X 7 21 0.290 25.2 530 7.0 0 146 S -Gls-Marvin shgc-0.33 0%S (2)30 0.300 26.1 784 18.9 0 568 W -Gls-Marvin shgc-0.33 0%S 12 0.300 26.1 313 34.8 0 417 N -Gls-Marvin shgc-0.34 100%S (2)96 0.280 24.4 2,338 10.1 0 968 N -Gls-Marvin shgc-0.33 100%S (2)36 0.300 26.1 940 10.2 0 366 N -Gls-Marvin shgc-0.37 100%S 24 0.380 33.1 793 12.0 0 287 E -Gls-Marvin shgc-0.33 0%S 18 0.300 26.1 470 34.7 0 625 E -Gls-Marvin shgc-0.37 0%S 12 0.280 24.4 292 38.3 0 459 UP-Ceil-16B-50 25.6 X 20 512 0.020 1.7 891 1.0 0 492 Subtotals for Structure:15,575 0 5,659 Infil.: Win.: 78.7, Sum.: 40.4 1,620 4.511 7,308 0.346 627 561 People: 200 lat/per, 230 sen/per:1 200 230 Equipment:0 1,200 Room Totals:22,883 827 7,650 C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 11 Detailed Room Loads - Room 3 - Second Floor (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:37.3 ft.System Number:1 Room Width:32.0 ft.Zone Number:1 Area:1,192.0 sq.ft.Supply Air:374 CFM Ceiling Height:9.0 ft.Supply Air Changes:2.1 AC/hr Volume:10,728 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:4 Actual Winter Vent.:61 CFM Runout Air:94 CFM Percent of Supply.:16 % Runout Duct Size:6 in.Actual Summer Vent.:80 CFM Runout Air Velocity:476 ft./min.Percent of Supply:21 % Runout Air Velocity:476 ft./min.Actual Winter Infil.:63 CFM Actual Loss:0.142 in.wg./100 ft.Actual Summer Infil.:32 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0sw 34 X 9 251.8 0.065 5.7 1,424 0.9 0 218 W -Wall-12F-0sw 38 X 9 342 0.065 5.7 1,934 0.9 0 296 N -Wall-12F-0sw 34 X 9 248 0.065 5.7 1,402 0.9 0 214 E -Wall-12F-0sw 38 X 9 306 0.065 5.7 1,730 0.9 0 265 S -Gls-Marvin shgc-0.37 0%S (3)12 0.280 24.4 291 20.5 0 246 S -Gls-Marvin shgc-0.37 0%S 12.2 0.280 24.4 298 20.5 0 251 S -Gls-Marvin shgc-0.3 0%S 30 0.300 26.1 783 17.6 0 527 N -Gls-Marvin shgc-0.34 100%S 20 0.300 26.1 522 10.4 0 207 N -Gls-Marvin shgc-0.28 100%S 6 0.370 32.2 193 10.2 0 61 N -Gls-Marvin shgc-0.34 100%S 32 0.300 26.1 835 10.3 0 331 E -Gls-Marvin shgc-0.37 0%S 20 0.280 24.4 487 38.2 0 764 E -Gls-Marvin shgc-0.34 0%S 16 0.300 26.1 418 35.7 0 571 UP-Ceil-16B-50 37.2 X 32 1192 0.020 1.7 2,074 1.0 0 1,144 Floor-20P-30 20 X 16.4 328 0.035 3.0 999 0.3 0 92 Subtotals for Structure:13,390 0 5,187 Infil.: Win.: 63.0, Sum.: 32.3 1,296 4.512 5,847 0.346 502 449 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:0 1,200 Room Totals:19,237 1,502 7,986 C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)West Metro Mechanical Plymouth, MN 55441 Page 12 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Basement 1,376 15,819 212 2-6 348 2,918 427 137 137 2 First Floor 1,376 22,883 306 4-6 456 7,650 827 358 358 3 Second Floor 1,192 19,237 257 4-6 476 7,986 1,502 374 374 Ventilation 6,871 1,027 2,870 System 1 total 3,944 64,810 776 19,581 5,626 869 869 System 1 Main Trunk Size:10x16 in. Velocity:782 ft./min Loss per 100 ft.:0.102 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.10 78% / 22%19,581 5,626 25,206 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency:0 AFUE 0 SEER Sound:0 0 Capacity:0 Btuh 0 Btuh Sensible Capacity:n/a 0 Btuh Latent Capacity:n/a 0 Btuh C:\ ...\West Metro M ... h Street.rh9 Tuesday, April 11, 2023, 9:30 AM