Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
survey sign
MEDICAL OFFICE BUILDING (2-STORY) ±44,000 SF FFE: 1024.0' LOT 1 ±4.47 AC.NO PARKINGNO PARKING T NO PARKING NO PARKINGNO PARKINGNO PARKING9.0' TYP. 26.0'9.0'TYP.18.0' 6.0'18.0'15.0'18.0'9 . 0 ' TYP . EXISTING STORMWATER MANAGEMENT 9.0'9.0'18.0'24.0'18.0'TYP.18.0'26.0'20.0'20.0'24.0'18.0'18.0'24.0'20.0'20.0'26.0'9.0' 9.0' 9.0' 9.0' 9.0' TYP. TYP. TYP. TYP. TYP. 5.4' 26.0'18.0' 7.0'18.0'24.0'18.0' 5.3'9.0'9.0'TYP.TYP.R3 . 0 ' R 2 6 . 1 'R2 0 . 0 'R4.0 '9.0'TYP.18.0'25.6' R4.0'R26.0'R3.0 'R2 6 . 0 ' R15.0'R4.0 'R1 2 . 0 'R6.5'R6.5'R4 . 0 ' R3.0' R1 0 . 0 'R11.0'R12.0'R5.7'R5.0 ' R20.0' R 1 5 . 0 ' R 5 . 0 '5.3'24.0'7.0'18.0'7.0'PROPOSED DRAINAGE AND UTILITY EASEMENT EXISTING DRAINAGE & UTILITY EASEMENT EXISTING DRAINAGE & UTILITY EASEMENT EXISTING DRAINAGE & UTILITY EASEMENT EXISTING ACCESS EASEMENT A N A A A A A A R N N M J G J M M J N N N N N N N N A A U H E H F H O Q PROPOSED DRAINAGE & UTILITY EASEMENT16.0'15.1'87.3'80.2'14.9'B B B B B B B B B V 24.0'24.0' R45.0' TRANSMISSION EASEMENT M M 10.0' 9.0'9.0'B G G G C J J D D F H I E E E E E E E E E P V S 10.0' R98.3'3.6'16.5 'PREPARED FORSITE PLANC400LAKEVILLEMEDICAL OFFICEKAMI INC.LAKEVILLEMNDATE:I HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION OR REPORT WAS PREPARED BYME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED PROFESSIONALENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.MNLIC. NO.MICHAEL C. BRANDT, PE04/21/202242661DATECHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT16083900504/21/2022AS SHOWNCJJCJJMCBBUILDING DATA SUMMARY AREAS PROPOSED PROPERTY 4.46 AC BUILDING AREA 44,000 SF (22.6% OF TOTAL PROPERTY AREA) PARKING REQUIRED PARKING 198 SPACES @ 1/200 SF PROPOSED PARKING 263 SPACES @ 5.98 RATIO ADA STALLS REQ'D / PROVIDED 7 STALLS / 11 STALLS PROPERTY SUMMARY LAKEVILLE MEDICAL OFFICE TOTAL PROPERTY AREA 4.46 AC PROPOSED IMPERVIOUS AREA WITHIN PROPERTY AREA 2.80 AC PROPOSED PERVIOUS AREA WITHIN PROPERTY AREA 1.66 AC TOTAL DISTURBED AREA 4.10 AC ZONING SUMMARY EXISTING ZONING C-3 (GENERAL COMMERCIAL) PROPOSED ZONING C-3 (GENERAL COMMERCIAL) PARKING SETBACKS SIDE INTERIOR = 15' REAR = 10' FRONT/PUBLIC ROW = 15' BUILDING SETBACKS SIDE INTERIOR = 10' REAR = 10' FRONT/PUBLIC ROW = 30' PROPOSED CURB AND GUTTER PROPERTY LINE PROPOSED FENCE SETBACK LINE RETAINING WALL PROPOSED STANDARD DUTY ASPHALT PROPOSED HEAVY DUTY CONCRETE PAVEMENT PROPOSED CONCRETE SIDEWALK LEGEND PROPOSED HEAVY DUTY ASPHALT This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.SHEET NUMBER 2022 KIMLEY-HORN AND ASSOCIATES, INC.767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114PHONE: 651-645-4197WWW.KIMLEY-HORN.COMK:\TWC_LDEV\Kami\Lakeville Medical Office\3 Design\CAD\PlanSheets\C4-SITE PLAN.dwg May 05, 2023 - 11:52am©BYREVISIONSNo.DATE1CITY COMMENTS03/01/2022CJJISSUED FOR PERMIT - NOT FOR CONSTRUCTION2ISSUED FOR PERMIT04/21/2022JFJ3RFI #1506/30/2022ZTR4MONUMENT SIGN 05/05/2023ZTRSITE PLAN NOTES 1.ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY REGULATIONS AND CODES AND O.S.H.A. STANDARDS. 2.CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 3.ALL INNER CURBED RADII ARE TO BE 3' AND OUTER CURBED RADII ARE TO BE 10' UNLESS OTHERWISE NOTED. STRIPED RADII ARE TO BE 5'. 4.ALL DIMENSIONS AND RADII ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 5.EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED, REMOVED OR RELOCATED AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, (UNLESS OTHERWISE NOTED ON PLANS) INCLUDING BUT NOT LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID. 7.SITE BOUNDARY, TOPOGRAPHY, UTILITY AND ROAD INFORMATION TAKEN FROM A SURVEY BY <SURVEYOR>, DATED XX/XX/XXXX. KIMLEY-HORN ASSUMES NO LIABILITY FOR ANY ERRORS, INACCURACIES, OR OMISSIONS CONTAINED THEREIN. 8.TOTAL LAND AREA IS 4.47 ACRES. 9.PYLON / MONUMENT SIGNS SHALL BE CONSTRUCTED BY OTHERS. SIGNS ARE SHOWN FOR GRAPHICAL & INFORMATIONAL PURPOSES ONLY. CONTRACTOR TO VERIFY SIZE, LOCATION AND ANY REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE PYLON / MONUMENT SIGN. 10.CONTRACTOR SHALL REFERENCE ARCH / MEP PLANS FOR SITE LIGHTING AND ELECTRICAL PLAN. 11.NO PROPOSED LANDSCAPING SUCH AS TREES OR SHRUBS, ABOVE AND UNDERGROUND STRUCTURES, OR OTHER OBSTRUCTIONS SHALL BE LOCATED WITHIN EXISTING OR PROPOSED UTILITY EASEMENTS AND RIGHTS OF WAY UNLESS SPECIFICALLY NOTED ON PLANS OTHERWISE. 12.REFERENCE ARCHITECTURAL PLANS FOR DUMPSTER ENCLOSURE DETAILS. 13.REFER TO FINAL PLAT OR ALTA SURVEY FOR EXACT LOT AND PROPERTY BOUNDARY DIMENSIONS. 14.ALL AREAS ARE ROUNDED TO THE NEAREST SQUARE FOOT. 15.ALL DIMENSIONS ARE ROUNDED TO THE NEAREST TENTH FOOT. 16.ALL PARKING STALLS TO BE 9' IN WIDTH AND 20' IN LENGTH UNLESS OTHERWISE INDICATED.NORTHKEYNOTE LEGEND PROPOSED B612 CURB AND GUTTER CROSSWALK STRIPING PER STRIPING NOTES ADA STALL/STRIPING NOT USED TRASH ENCLOSURE - REFER TO ARCH AT-GRADE LOADING DOCK - REFER TO ARCH PAD-MOUNTED TRANSFORMER SCREEN WALL - REFER TO ARCH A B C D E F G H M N O Q R P PEDESTRIAN CURB RAMP STOP SIGN PAVEMENT FLUSH WITH SIDEWALK L I J K OUTFALL CURB 4" WHITE SOLID LINE 6" BOLLARD, SEE DETAIL SHEET. MONUMENT SIGNS T U DRIVEWAY APRON PER CITY OF LAKEVILLE STANDARD PLATE LV-ST-4 V ADA ACCESSIBLE SIGN AND POST, SEE DETAILS. W X CONCRETE SIDEWALK MEET & MATCH EXISTING CURB 5-FT CURB TRANSITION FROM 6" TO 0" LIGHT POLE BASE - REFER TO ELECTRICAL PROPOSED BIG BLOCK RETAINING WALL WITH FENCE (DESIGN BY OTHERS). SEE DETAILS. NOT USED NOT USED 4 D/F Monument Sign Scale: 1/2’’ = 1’-0’’1 A B D C F TENANT TENANT TENANT TENANT TENANT 4” 148” 48” 92” 16” 24”96” 198” 2’’ 2’’ 2’’ 2’’ 2’’ 2’’ 2’’ PROFILE 13” 18” 30” 30” 18” 18” 18” 18” 1.1 DF Monument Sign STEEL STRUCTURE MOUNTED TO EXISTING MASONRY BASE - EMBEDDED 3/4’’ X 25’’ THREADED ROD ANCHORS AND HARDWARE (20’’ EMBEDMENT) MECHANICALLY MOUNT CABINET OVER 2- 4’’ SQ. STEEL TUBES (3/8’’ WALL) - WELDED TO 16’’ X 12’’ X 3/4’’ STEEL MOUNTING PLATE - 1 1/4’’ X 1 1/4’’ X 1/2’’ STEEL GUSSETS Description Install Mount Illumination DF Cabinets Cornice Reveals Flashing Tenant Panels Base 2’’ X 2’’ X 3/16’’ WALL ALUMINUM ANGLE FRAME WELDED CONSTRUCTION - .080 ALUMINUM RETURNS - 2’’ ALUMINUM ANGLE RETAINERS 1 1/2’’ ALUMINUM DIVIDER BARS - PAINTED TO MATCH ALLINA GRAY: MP74935 (PMS 428C) 2’’ X 4’’ ALUMINUM CHANNEL - WELDED CONSTRUCTION - .080 ALUMINUM TOP - PAINTED TO MATCH ALLINA GRAY: MP74935 (PMS 428C) 1’’ X 2’’ ALUMINUM CHANNEL REVEAL - TO MATCH ALLINA GRAY: MP74935 (PMS 428C) .063 ALUMINUM FLASHING - PAINTED TO MATCH ALLINA GRAY: MP74935 (PMS 428C) 1 1/2’’ X 1 1/2’’ X 1/8’’ ALUMINUM ANGLE FRAME RETAINER - 1/8’’ ALUMINUM PANELS (CNC) - PAINTED TO ALLINA GRAY: MP74935 (PMS 428C) 1/2’’ CLEAR ACRYLIC PUSH-THRU GRAPHICS - 1/4’’ PROJECTION (GRAPHICS/COLORS TBD BY TENANT) MASONRY BASE (BY OTHERS) A B D E E C F PHOTOCELL CONTROLLER SLOAN DS SIGNBOX 3 6500K WHITE LED MODULES 88 L.E.D. MODULES - 88 LINEAL FEET TOTAL (5) - 60C2-60W (701507-60C2) 100-277 VAC 60 Hz 0.80 A - 60 W @ 12 VDC8 Tenant 1 | Allina Health Criteria .063 ALUMINUM FLASHING LAKEVILLE SIGN CRITERIA: 20' HIGH MAX, 15' SETBACK, AND 100 SQ,FT MAX 8 3/4” 5 7/8” 1/2’’ CLEAR ACRYLIC PUSH-THRU GRAPHICS - 1/4’’ PROJECTION (CNC) FIRST SURFACE ALLINA CUSTOM TRANSLUCENT VINYL - SECOND SURFACE TRANSLUCENT WHITE VINYL DIFFUSER (230-20) 9611 James Ave S. Minneapolis, Minnesota 55431 952 641 9600 archetypesign.com This print is meant as a representation of a sign show vin consideration of being manufactured by Archetype. Materials may influence final result. Samples available upon request. Graphic Design time is included in the total purchase price. Designs contained herein are not meant to be exhibited to others outside of included parties and employees. Designs received from Archetype may not be manufactured by others without reimbursement for time spent in the creation of these designs or any resemblance. Drawings may contain elements considered artistic intellectual property of Steve Carpenter, owner. ©Archetype Page: Type: Approved: Contact: Description: Project: Job Number: Date: Rev. 1: Rev. 2: Rev. 3: Rev. 4: Rev. 5: Designer: Steve Hirtz 952 641 9629 steveh@archetypesign.com Lakeville Medical Office Building Q-102512 10.12.22 10.17.22 10.18.22 01.12.23 01.17.23 01.20.23 DG LA212345 1.2 D/F Monument Sign Detail Footing Detail (By Others) 3/4’’ Base Plate Detail Scale: 1/2’’ = 1’-0’’ Scale: NTS Scale: 1 1/2’’ = 1’-0’’ 2 4 3 DF Monument Sign Details 4” 142” 48” 92” 16” 24”96” 198” 2’’ 2’’ PROFILE 11”11”8" 20" GRADE 11” 8” 16” 12” 7/8” 4’’ SQ. STEEL TUBE STEEL GUSSET 1/2” 1 1/4” 2’’ X 4’’ ALUM. CHANNEL 2’’ ALUM. ANGLE FRAME LED MODULE 4’’ SQ. STEEL TUBE (143’’ LENGTH) MOUNTING ANGLE & HARDWARE STEEL MOUNTING PLATE THREADED ANCHORS/ HARDWARE (LEVELING NUTS) INCOMING ELECTRICAL CENTER OF BASE MASONRY BASE (BY OTHERS) 1’’ X 2’’ ALUM. CHANNEL 1’’ X 2’’ ALUM. CHANNEL 1/8” ALUM. FACE 1/2” ACRYLIC PUSH-THRU 48" Scale: 1 1/2’’ = 1’-0’’ 2’’ ALUM. ANGLE FRAME ATTACHMENT SCREW 1 1/2’’ ALUM. ANGLE ADHESIVE 1/8” ALUM. FACE 1/2’’ ACRYLIC PUSH-THRU 18” 13” c.c. c.c.c.c.c.c. c.c. c.c. 88 1/2"16 1/2" .063 ALUMINUM FLASHING 9611 James Ave S. Minneapolis, Minnesota 55431 952 641 9600 archetypesign.com This print is meant as a representation of a sign show vin consideration of being manufactured by Archetype. Materials may influence final result. Samples available upon request. Graphic Design time is included in the total purchase price. Designs contained herein are not meant to be exhibited to others outside of included parties and employees. Designs received from Archetype may not be manufactured by others without reimbursement for time spent in the creation of these designs or any resemblance. Drawings may contain elements considered artistic intellectual property of Steve Carpenter, owner. ©Archetype Page: Type: Approved: Contact: Description: Project: Job Number: Date: Rev. 1: Rev. 2: Rev. 3: Rev. 4: Rev. 5: Designer: Steve Hirtz 952 641 9629 steveh@archetypesign.com Lakeville Medical Office Building Q-102512 10.12.22 10.17.22 10.18.22 01.12.23 01.17.23 01.20.23 DG