18105 Gavel La
RECEIVED By Lucas Ritchie at 4:16 pm, May 25, 2023 CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: LA201963, 201964, 201965, 201966 Legal Description: Lot21-24BIock 2 Subdivision: GLACIER CREEK 3RD ADDITION Address: 18105 18109 1 811 3 18117 Gavel Lane We hereby certify that on _ 17th day of Mav 2023 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: //P to _ r Hawkinson Signature: Date: May 19, 2023 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 Encls. 1 11x17 g10 910 3 i7 0 L. fn / 910 3 / Lot 21&24 Lot area = 6216 SF House area = 2652 SF Porch area = 96 SF Deck area = 200 SF Sidewalk area = 92 SF Driveway area = 326 SF Total Impervious Area = 3366 SF Impervious Coverage = 54.2 % nc r I in Nntac _ I . ns a roc construction entrance 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1 0% 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required 7. Retaining walls are conditional; Wall installed if the grade exceeds Wall will not be installed if the grade is 3 1 or less. General Notes: 1. Grading plan by Pioneer Engineering last dated 12-03-2021 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4 No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. X A, 914 X 9 j33 x 91\9 g10 g10 9 9110 966 975 / -X 961 t Ott ‘AlYel°u -\\'tiy g X 0(\a 0t 910 of0.0°o e�i Per e0semO 912 7- / / g12.0 / 912.0®I 912\11_ Lot 22&23 Lot area = 4736 SF House area = 2662 SF Porch area = 94 SF Deck area = 200 SF Sidewalk area = 90 SF Driveway area = 326 SF Total Impervious Area = 3372 Impervious Coverage = 71.2% 912'2 X 9125 x • 0 ■ 000.00 000 00 ) PItNEERneenng, P.A, CIVn. ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS 9610X 969 g724 g1\1 X Denotes iron pipe Denotes service Denotes television box Denotes electric box Denotes telephone box Denotes existing elevation Denotes proposed elevation Denotes drainage flow direction D t ik eno Denot design esspe es proposed retaining wall ed and built by others. 3:1. REVISED X O\ 912 g66 6 g653X X9695 A tt 00Ot br 96g.3 x 10.0 \g656X x g69 6 \\ V"g6g,3 \\ 9656 X \ 955 aX g69 3 X House elevations (Proposed) / As -built Lowest Floor Elevation Top 0f Foundation Elev. Garage Slab Elev 5/17/23 : (971.2) / : (974.4) / 974.4 ® Door : (974.0) / 974.0 GRADING AS -BUILT We hereby certify to Brandt Anderson Homes Inc that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 04/15/22. Signed: BY: ressltirial Land Surveyor Minnesota License No. 42299 email-phawkinson@pioneereng.com eer Engineering, P A Lot 21, 22, 23, 24, Block 2, GLACIER CREEK 3RD ADDITION according to the recorded plat thereof 2422 Enterprise Dnve Ph. : (651) 681-1914 Dakota County, Minnesota Mendota Heights, MN 55120 Fax: (651) 681-9488 www.ploneerengcom Address: 18105 18109 18113 18117 Gavel Lane, Lakeville, Minnesota House Model: Trillium, Sable Elevation: N/A Buyer: Brandl Anderson Homes S g661 961x 0' 10' 20' 111 Scale: 1" 20' Benchmark: Top Nut Hydrant L21 B2 Elevation = 973.67 Revisions I 04-19-22 Stake house 2) 07-14-22 Re -stake house 3) 05-17-23 Grading As -built Certificate of Survey for: Brandl Anderson Homes Inc Project # .121205009 (Folder #:8625IDrawn by P.H $ © Pioneer Engineering 221 River Ridge Circle South, Suite 100 Burnsville, MN 55337 Phone- (952)898-0230