Loading...
HomeMy WebLinkAboutLA212694-8309 183rd Street West - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND REFANOT USEDPRODUCTCBD5/4X6 CEMENT BD. TRIMREFMATERIAL LEGENDECEMENT BD. SIDINGPRODUCTGFHCEMENT BD. SHAKES5/4X8 CEMENT BD TRIMNOT USEDC.B. BOARD-N-BATTEN1X4 FREIZE BD1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-7272A D.R. HORTON COMPANY-N.T.S.-TYPICAL CORNER DETAILHARDBOARD TRIMHARD BOARD SIDINGHARD BOARD SIDING2-SIDED OUTSIDE CORNER2-3/4" .96"3-1/2"SHEATHINGHDBD TRIMLIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLEAT SHUTTERS ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM6" TRIM5" TRIMAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIMDRAWN: 4-6-2017-MGCUST:SPEC HOMEF422-A-4.0CLIFTONREVISED: 10-16-2017-KBXXXXXADDRESS NUMBER4:12 PITCH812FFSTEEL PANEL OVERHEAD DOORICE & WATERALUMINUM FLASHINGBEHIND STOOP8128128128:12 8:12 1xT.O. 2040 SH (FIXED / BLACKENED) R.O. 24"x48"12"x48" PANEL SHUTTERAMERICAN CLASSIC1'-0"1'-0" HEEL 6 1/4" 9'-0"1'-0"AAAABBBBCCCC4:128:126' RIDGE VENT 8:128:128:126' RIDGE VENT 52' RIDGE VENT 1'-0"1'-0"1'-0"1'-0" 1'-0" 1'-0" 1'-0"1'-0"1'-0"1'-4" 1'-4"3'-3"3'-3"1'-4"A1A1'A' ROOF PLAN1/8"=1'-0"FCD3 1/2" TRIM 5" TRIM3 1/2" TRIM5" TRIM330.75 SQ FT TOTAL FACING70 SQ FT STONE = 21.16%PC#1004: 6-3-2022-RKLEFT ELEVATION1/8"=1'-0"MAINTAIN 6" MIN SEPARATION WOOD to EARTHRIGHT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"812ASPHALT SHINGLESFLASH OVER ALL EXT OPGS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806F812MAINTAIN 6" MIN SEPARATION WOOD to EARTH42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE2x8:12 PITCHMAINTAIN 6" MIN SEPARATION WOOD to EARTHF8:12 PITCH8:12 PITCHF8'-0"8" REALWOOD COLUMN w/2x10 CAP & BASE1'-0" HEEL1'-0"1'-0"HEEL9'-1 1/8"1'-0"1'-0"1'-0"FFFPERMIT/CONSTRUCT PLANS8309 183RD STREET W.LOT 6 BLOCK 6 - PINNACLE RESERVE 4TH ADD.PERMIT/CONSTRUCT: 5-15-23-RKConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode05/31/2023dmathews 24" TOWEL BAR10" TREAD CUT 16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHDRAIN TILESLEEVES1766 FOUND. SQ. FT.6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)8" THICK POURED CONC. WALL16"x8" FTG.MIN. 3'-6" BELOW GRADEUNEXCAVATED16'-3" M.O.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.UP16RDRAIN TILESLEEVES16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHR/I 3/4BFUTURETPH FAMILY RM16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH948 SQ. FT.288 SQ. FT.62 SQ. FT.MECH.30"A/CUNFINISHED468 SQ. FT.BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMBRACING ATFULL/LOOKOUTFOUNDATIONBSMT ONLYNOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONS34x48 FBGLSHOWERSURROUNDNOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOM2-82-82-82-8BRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEMDROPPED BEAMDROPPED BEAM BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEM18" FLOOR TRUSSES18" FLOOR TRUSSES18" FLOOR TRUSSESLOCATIONVERIFY16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHSLEEVESSEWER & WATERSLEEVERADONVENT PIPEBRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEM(OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK POURED CONC. WALL16"x8" FTG.MIN. 3'-6" BELOW GRADEBASEMENT PLAN1/4"=1'-0"INSTALL PER MFRS SPECSINSTALL PER MFRS SPECSINSTALL PER MFRS SPECSNOTE:8'-4" HIGH POURED CONC. FOUNDATION WALL TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRSUMPFILL14"x8" CONC. FTG.POURED CONC. WALL8" THICKMIN. 3'-6" BELOW GRADEDRAIN TILECLIFTON F422-A-4.0PC#1026: 8-11-2022-LLPC#1052, 1063: 8-11-2022-LLPERMIT/CONSTRUCT: 5-15-23-RKWINDOW & DOOR SCHEDULE-WALKOUTCALL-OUTU-FACTORROUGH OPENING6068 SGD0.3172 1/8" X 80"LOCATIONSHGCFAMILY ROOM0.323050 SH0.3136 1/4" X 60 1/4"#11BEDROOM0.31FOUNDATION INSULATIONFRONT FOUNDATION WALL:-19 SQ FT/61.5 LIN FT= 0.31 RATIOR-10REAR FOUNDATION WALL:-24 SQ FT/48 LIN FT= 0.5 RATIOLEFT SIDE FOUND. WALL:-89 SQ FT/56 LIN FT= 1.58 RATIORIGHT SIDE FOUND. WALL:-82 SQ FT/42.5 LIN FT= 1.92 RATIO-FOUNDATION INSULATIONRATINGS ARE BASED ONLESS THAN 2.6 AIR CHANGESPER HOUR DURING THE AIRLEAKAGE TESTR-10R-15R-15REQUIREMENTSTREATED 2x10's 16" ON CENTER (1) 2x10 TREATED JOIST W/ (1) 2x10 CEDAR RIM5/4" CEDAR DECKING2x10 GALV.HANGERS1/2"=1'-0"DECK FRAMING DETAILS18'-4"9'-0" 9'-0"6x6 POST18" CONC.POST FTG.6x6 POST20" CONC.POST FTG.2x4 SWAY BRACING AS REQ'D2x10 GALV.HANGERSUSP LTS19-TZCONNECTORS ON2x12 BLOCKING ORUNDERSIDE OF 2X10 TREATED JOISTSTREATED 2x10's 16" ON CENTER2'-0" MAXEQUALEQUALEQUAL2'-0" MAXUSP LTS19-TZCONNECTORS ON2x12 BLOCKING ORUNDERSIDE OF 2X10 TREATED JOISTSUSP LTS19-TZ1/2"=1'-0"REAR DECK LEDGER SECTIONFLASHING ABOVEDOORTHRESHOLDAND BELOW TREATED2x8 LEDGERSTRTD 2x_ JOISTS16" O.C.(8) 10d COMMON NAILSTREATED 2x85/4" DECKINGRIM BOARD1-1/8" OSB16" FLOOR TRUSSES(4) PER DECK, RATED AT 750 # EACHSPACED EVENLY, MAX. 24" FROM END OF LEDGERLATERAL LOAD CONNECTION:USP LTS19-TZ w/ LBP12-TZ WASHERWALLSROCK RETURN 1/2"=1'-0"DECK LEDGER DETAIL3/4" SUBFLOOR6 1/4"VARIES2x_ PORCHLEDGER2x6 EXTERIOR WALL16"FLOORTRUSSES.2""MIN...3/4"1st FLOOR WALLSSUBFLOOR9'-1 1/8"BASEMENTWALLS 2" FROM TOPLAG SCREW TO BEMIN. 2" FROM EDGE16" O.C. UNDER 10'-0" SPAN12" O.C. OVER 10'-0" SPANSUBFLOOR TOTOP OF LEDGEROF LEDGER19.2" O.C.FLOOR TRUSSESBLOCKING, LAID FLATTRTD (2) 2X12(8) 16D NAILS ON INSIDEBLOCKING, LAID FLATTRTD (2) 2X12(8) 16D NAILS PER SIDE(8) 30D NAILS ON OUTSIDESCREWS (MIN. 4" LONG)1/2" DIAMETER LAGINSTALLED STAGGERED IN 2 ROWS1/2" DIA. LAG SCREWS TO BE21" O.C. UNDER 8'-0" SPANTOP/SILL PLATE W/ATTACH RIM BOARD TO8D NAILS @ 6" O.C.SUBFLOOR W/ATTACH RIM BOARD TO8D NAILS @ 6" O.C.TO TOP & BOTTOM OFATTACH 1-1/8" OSB RIM BDEACH FLOOR MEMBERW/ 8D NAILSOF DECK LEDGERUSP LTS19-TZ STRAPS TO BE ATTACHED TO DECK JOISTOR 2X12 BLOCKING AND ANCHORED INTO FLOOR TRUSS.(4) STRAPS PER DECK/PORCH, RATED AT 750# EACH,TO BE SPACED EVENLY. MAX 24" FROM END OF DECK LEDGERMINIMUM 3" PENETRATION THRU OSB RIM & FLOOR TRUSSANCHORS AT 6'-0" O.C.BLOCK AT MIDPOINT14x8 CONC FTG6" HALF-HIGH CURBTREATED BOTTOM PLATE2x6 STUDS AT 16" O.C.2x6 BRNG WALLCONC PAD FTG30x30x12CONC PAD FTG30x30x12SIMPSON DTT1Z ORSIMPSON DTT1Z ORSIMPSON DTT1Z ORAC HVWH F.D.6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGHBRACINGFOUND.SYSTEMBRACINGFOUND.SYSTEMWSERV3'-0"7'-0"9'-0"13'-4"56'-0"9'-0" 65'-0"42'-6"22'-6"20'-4"13'-6" 17'-8"4'-5 1/2"1'-11"7'-4"17'-6 3/4" 3'-6"3'-2 1/2"3'-0"18'-2"16'-0"4'-10"14'-1 3/4" 4'-1" 2'-2" 5'-6"4'-8"25'-11"30'-1" 5'-0"4'-0" MAX.4'-0" MAX.4'-8"4'-8"65'-0"39'-0"13'-6"20'-10"2'-3 1/2"2'-3 1/2"16'-3"2'-8"6'-4" 6"8'-6"9'-4"9'-0"6 1/4"7 1/4"1 1/2"5'-5"4'-1"IS BEING FINISHEDWHEN ONLY THE REC RMADD 2--8 DOOR HEREAPPROVED HANGERS2x10 CEDARTREATED 2x10 JOISTSCEDAR DECKINGPOSTSPOST ANCHORAPPROVED GALV.BOTH ENDS2" GALVANIZED DRIP CAP(DO NOT FASTEN DECKING THROUGH FLASHING)5 1/2" FROM TOP OF SUBFLOORTO TOP OF JOISTSAT 16" O.C.5/4" x 6" 1/2"=1'-0"DECK DETAILS6x6 TREATEDRIM16"16" OR 18" DIAMETER5'-0" FROST PROTECTIONCONC. PIERCEDAR3'-0" MIN.ALUMINUMRAILING SYSTEM(3) 2X10 TRTDHEADER(2) 2x10 TREATED HDR W/ (1) 2x10 CEDAR RIMX2.02x6 WALKOUT WALL2x6 STUDS AT 16" O.C. 8" POURED CONC. WALLTREATED BOTTOM PLATE6" CURB, 2" LEDGE16x8 CONC. FTG.MIN. 3'-6" BELOW GRADE2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALLTREATED BOTTOM PLATE18x8 CONC. FTG.8" THICK, 4'-4" HIGH6-0 SGDENLARGEDCONC. PAD3050 SH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALLTREATED BOTTOM PLATE18x8 CONC. FTG.8" THICK, 4'-4" HIGH2-8 10'-0"8'-4"39'-0"18'-4"20'-8"7'-1"13'-7"20" CONC. PIER FTG6x6 TREATED POSTMIN. 3'-6" BELOW GRADE18" CONC. PIER FTG6x6 TREATED POSTMIN. 3'-6" BELOW GRADE9'-4"9'-0"(3) 2x10 FLUSH HDR - (2) TREATED AND (1) CEDARTREATED 2x10's 16" ON CENTER JOIST HANGERS BOTH ENDSFUTUREBEDRM12'-0"LOOKOUT WALL 12'-0" LOOKOUT WALL 2x6 WALKOUT WALL2x6 STUDS AT 16" O.C. 8" POURED CONC. WALLTREATED BOTTOM PLATE6" CURB, 2" LEDGE16x8 CONC. FTG.MIN. 3'-6" BELOW GRADEPERMIT/CONSTRUCT PLANS8309 183RD STREET W.LOT 6 BLOCK 6 - PINNACLE RESERVE 4TH ADD.PLAN OPTIONSWATER SOFTENERWALKOUT BASEMENTENLARGED REAR CONC. PATIO6" CURB, 2" LEDGEPOURED CONC. WALL48"x10" CONC. FTG.8" THICK, 8'-4" HIGHUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. WALL SECTION 2F1 RETAINING WALL TYPESTAIRWAY FOUNDATION WALL(3) #4 LONGITUDINAL BARSAT TOP OF FOOTING#4 HORIZ. BARS@ 24" O.C.8" MIN. C.I.P.CONCRETE WALLVERTICAL BAR OPTIONS:#5 BARS @ 24" O.C.OR #6 BARS @ 36" O.C.#4 BARS @ END &BEND OF HOOK5'-0" HOOK OPTIONS:#5 HOOKS @ 12" O.C. OR#6 HOOKS @ 18" O.C.TRANSVERSE BARS OPTIONS:#5 BARS @ 24" O.C. OR#6 BARS @ 36" O.C.10" THICK C.I.P.CONCRETE FOOTING1'-6"3'-6"2" TO VERTICAL BARS & HOOKS1'-6"4'-0"2" 3" 8'-4" MAX.SLAB-ON-GRADE12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 48" O.C. MAX. OR EQUIV.FRAME WALL ABOVESLAB-ON-GRADE &INSULATION BY OTHERS6" MIN. STEM WALL10BWPsAbove(2)7-1/4 Versa-Lam(3)14" Versa-Lam (2)7-1/4 Versa-Lam 1ST FLOOR PLAN1/4"=1'-0"1866 SQ. FT.NOTE:9'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 8'-0" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRFOYER2W 3050 SH16x7 OVERHEAD DOORON ALL WALLS & CEILINGGYP. BOARDNOTE: CARPET30 SQ. FT.8" WIDE DROPPED SOFFIT(SEE SECTION)DROPPED BEAMBEDRM #1CPT.LAUNDRYWD2x6 WALL22x30 ATTIC ACCESS INSIDE FRAMING W.I.C.CPT.GARAGESLOPE TO DOORS4" CONC FLOOR464 SQ. FT.TYPICAL 2x6 GARAGE WALLSCONC.BATH #1TPH INSIDE FRAMING BEDRM #2CPT.2-82-830"TPH 24" TOWEL BAR5-0 FBGL TUB/SHWRBATH #26-0 x 8-0 S.R.O.2-82-82-82-02-83050 SH3-0TRANSOM OVER PORCH2-82-82W 3050 SH2W 3050 SH6068 SGDCOVEREDCEDAR DECK1'-6"3'-6"9'-6 1/2"1'-8"3'-10" 5'-10"1'-2 1/4"2'-3 3/4"4'-8"4'-0"3'-2"SILLCOCK2x6 WALL2W 3050 SH 2-8W.I.C.CPT.8'-2"9'-8"2-8STEPSFAMILYROOMCPT.HD FLR.HD FLR.DININGROOMLAUNDRY ROOM CABINETS SHOWER 34x60 FBGLS 2X6 WALL FRAMEDHD FLR.HD FLR.HD FLR.HD FLR.HD FLR.HD FLR.HD FLR.WINDOW & DOOR SCHEDULE - MAIN LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DOOR0.31FOYER0.231RADONVENT PIPEBEDROOM #2136 1/4" X 60 1/4"38 1/4" X 95 1/4"3050 SH0.310.31FAMILY ROOM2W 3050 SH10.310.3172 1/8" X 60 1/4"DINING ROOM2W 3050 SH10.310.3172 1/8" X 60 1/4"BEDROOM #12W 3050 SH10.310.3172 1/8" X 60 1/4"MFD TRUSSES AT 24" O.C.MFD TRUSSES AT 24" O.C.4-0 BI-FOLD DROPPED BEAM ALUM RAILING8" REALWOOD COLUMNCLIFTON F422-A-4.0PC#1026: 8-11-2022-LLPC#1052, 1063: 8-11-2022-LLPERMIT/CONSTRUCT: 5-15-23-RKHD FLR.3'-0"3'-0"11'-11" 2020 FX2020 FX TRANSITION BREAKNOTE:85"(L) x 35" A.F.F.(H)165 SQ. FT.BEDROOM #122020FX24" X 24"0.310.322x6 WALL 22x30 ATTIC ACCESS 2-2x10 DRP BMBEDRM. #3CPT.2x6 WALL 2x6 WALL 0.3172 1/8" X 80"0.326068 SGDSTD DINING139"39"15"INSIDE FRAMING10" TREAD CUT DN16R5'-0" 8'-2"39'-0"65'-0" 56'-0"9'-0" 12'-2"6'-0"11'-4"26'-6" 65'-0"42'-6"22'-6"18'-4"20'-8"39'-0"13'-6"20'-10"4'-8"20'-4"2'-8"6'-4"13'-6" 9'-0"6'-9"6'-9"2'-4"2'-4"16'-7 1/2"5'-3 1/2"6'-3"17'-11"7'-0"13'-8"8'-2"6'-2"6'-10"6'-10"16'-8"9'-4"2'-8"5'-8"5'-8"10'-5"10'-5"4'-0"8'-0" 4'-11" 5'-0" 3'-2" 9'-10" 2'-5" 26'-6"1'-6"4'-10"3'-8 1/2"3'-10"10 1/2"1'-0 1/2"4'-2 3/4"8'-9 3/4"10'-10"5'-6"12"12"10'-0"3'-9 3/4"9'-4"5'-8 3/4"9'-8"COVERED2-8FLOOR DIRECTION FRONT-BACK FLOOR DIRECTION FRONT-BACK 3'-10"5'-0"(2) 2-02-62'-8"3'-8"2-82'-2"10'-9 3/4"2'-4"LINEN3'-6"X3.0SURFACEMOUNTED L.T.REF.SINK DW12" OVERHANG INSIDE FRAMING INSIDE FRAMINGOVENMICRO HOODCIRCUITKIT.HD FLR.COOKTOP7'-0" CABTS. 7'-3" TOP 4'-2"6'-9 1/2"9'-8 1/2"4'-4 1/2"3'-7" TOP14'-10"9'-6 3/4"VENT HOOD TO OUTSIDE GAS FPRO 42"x40 1/8"6'-4"PERMIT/CONSTRUCT PLANS8309 183RD STREET W.LOT 6 BLOCK 6 - PINNACLE RESERVE 4TH ADD.PLAN OPTIONSCORNER GAS FIREPLACESURFACE MOUNTED LAUNDRY TUBSIGNATURE KITCHEN W/GAS COOKTOPKITCHEN UNDER COUNTER LIGHTSLAUNDRY ROOM CABINETS(2)11-7/8 Versa-Lam(2)7-1/4 Versa-Lam (2)7-1/4 Versa-Lam (2)9-1/2 Versa-Lam8125555 3.58ConnectionsPFHPFH-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3.53.5 1ST FLOOR PLAN1/4"=1'-0"BEDRM #1LAUNDRYW.I.C.GARAGECOVEREDCONC.BATH #1BEDRM #2BATH #2 PORCHCOVEREDDECKW.I.C.FANLSDSSPRINKLERSYSTEMRECEPTACLEGFISSS WP SFANSDPHSD/CMDSSSGFIGFISSS WP SS S S SFANLDINING RMLLLTCHIME SLLSHCP S GFIS SMART HOMESYSTEM RECEPTACLELLLLLLLLLLCLIFTON F422-A-4.0PC#1026: 8-11-2022-LLPC#1052, 1063: 8-11-2022-LLPERMIT/CONSTRUCT: 5-15-23-RKCDROUGH-IN DATAW/ BLANK PLATEELECTRICAL PLAN1/4"=1'-0"UNFINISHED BASEMENTFUTURE BEDRMR/I 3/4BFUTUREFAMILY RMMECH.UNFINISHEDA/CWPS SDS RADONVENT PIPESEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLESUMPGFILOW VOLTAGESYSTEM RECEPTACLEGFI15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEACHVWHF.D.WSFUT WATER SOFTRECEPTACLE FORERVUNEXCAVATEDFILL LLLLFAMILYROOMSSS CEILING FANROUGH-INSSFOYERRADONVENT PIPEBEDRM. #3SD/CMDSDLLSSLSELECTRICAL PLANX4.0WPSKIT.LPHLLLDWSLUSBDISP.CSTECHTUBEPERMIT/CONSTRUCT PLANS8309 183RD STREET W.LOT 6 BLOCK 6 - PINNACLE RESERVE 4TH ADD.PLAN OPTIONSCORNER GAS FIREPLACESURFACE MOUNTED LAUNDRY TUBSIGNATURE KITCHEN W/GAS COOKTOPKITCHEN UNDER COUNTER LIGHTSLAUNDRY ROOM CABINETSPLAN OPTIONSWATER SOFTENERWALKOUT BASEMENTENLARGED REAR CONC. PATIOSVENT HOOD TO OUTSIDE 24" U.C.LIGHTS12" U.C.LIGHTS12" U.C.LIGHTSPEND.PEND.PEND.S 1/4"=1'-0"FAMILYROOMBEDRM #2COVEREDPATIOBEDRM #3CROSS SECTION B-B1/4"=1'-0"CROSS SECTION A-ABEDRMW.I.C.BATHGARAGE1/4"=1'-0"CROSS SECTION C-C812812FAMILYROOMKIT. BATHMFD TRUSSMFD TRUSSSLOPE TO DOORS4" CONC. FLOOR18" MFD FLOOR TRUSSES3/4" SUBFLOOR18" MFD FLOOR TRUSSES3/4" SUBFLOOR3-1/2" CONC. FLOOR18" MFD FLOOR TRUSSES3/4" SUBFLOORHAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATABATH 2CLIFTON F422-A-4.0PC#1026: 8-11-2022-LLPC#1052, 1063: 8-11-2022-LLPERMIT/CONSTRUCT: 5-15-23-RKCONC WALL8'-4" POUREDCONC WALL39'-0"1/4"=1'-0"CROSS SECTION C-CMIN HEADROOM 124CONC. STOOPDROPPED BEAMCONC. PORCHCOVERED1/4"=1'-0"CROSS SECTION A1-A154'-6"1'-0"42'-6"1'-0"21'-0"40'-6"1'-0"1'-0"1'-0"1'-0" 9'-8 3/4" 8'-2" 9'-8 3/4" 8'-2" 8"1'-0"1'-0"1'-0"1'-0"9'-1 1/8"9'-1 1/8" 9'-1 1/8" 10'-9 3/8" 9'-1 1/8" 9'-8 3/4" 8'-2" 6'-8"16'-8"1'-0"1'-0" 8"1'-0"8" 4 1/2"6'-4"6'-4"1'-0"X5.0PERMIT/CONSTRUCT PLANS8309 183RD STREET W.LOT 6 BLOCK 6 - PINNACLE RESERVE 4TH ADD. FOUNDATION DETAILAT FOOTING STEP LOCATIONS1S1DescriptionDateRevisionProject Number:Date:S11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20233.0011-1-232023 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2S1WALL SECTIONLOOKOUT WALL CONDITION3S1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4S1WALL SECTIONFULL HEIGHT WALL CONDITION5S1REBAR TABLE6S1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2023©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS: F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE: SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE 1,500 PSF MINIMUMGENERAL NOTES1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3. 112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOILPRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THERESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGNFOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW ANDCONSENT OF THE HANSON GROUP.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2023.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/S1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/S2FLOOR TO SILLCONNECTION SEE 1/S2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4 x 5'-0" HOOKS @ 24" O.C.EMBEDDED IN FOUNDATIONWALL & CAST INTO SLAB(MAY REDUCE 2'-0" LEG LENGTH& DRILL IN & EPOXY 8" MIN.INTO FOUNDATION WALL)3'-0"NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)2'-0"8'-0" OR LESS9'-0" MAX.10'-0" MAX.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2023©DescriptionDateRevisionJanuary 1, 2023Project Number:Date:3.001S22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2346665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1S2BRICK LEDGE INFO5S2WALL SECTIONAT WINDOW WELL LOCATIONS6S2STOOP INFO7S2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2S2BLOCKING DETAILFLOOR JOIST CONDITION3S2BLOCKING DETAILFLOOR TRUSS CONDITION4S2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/S1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/S1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/S1 OR 3/S1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/S1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/S2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/S1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)FLOOR MEMBERSPACING16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/ASLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.* FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERNAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/S1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/S1LOOKOUTWALLSEE 3/S1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.BACKFILL HEIGHT (NOT TO EXCEED 10'-0")SEE 5/S1 FOR TYPICALFOUNDATION WALL &FOOTING CONSTRUCTIONMAINTAIN MIN. 6" WIDESTEMWALL WITHEXTERIOR LEDGEWOOD FLOORSYSTEM BY OTHERSBACKFILL BELOW EXTERIORSTOOP SLABS WITH COMPACTEDGRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM)FLASHING &WATERPROOFINGBY OTHERSSTOOP SLAB BY OTHERS* SEE 1/S2 FOR FLOORTO SILL CONNECTION112" CLEARBUILD UP w/ RIGIDINSULATION BELOW SLABTO MAINTAIN 10'-0" MAX.BACKFILL HEIGHT ASREQ'D OR PROVIDE SITESPECIFIC ENGINEERING(MAY SUBTRACT 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY & CLAY SOILS DUE TO GRANULAR FILL BELOW STOOP SLAB) * MODIFIED CLEAR HEIGHT* SEE REBAR TABLE 6/S1FOR VERTICAL REBAR* SEE 2/S2 FOR ANCHOR BOLTS* FOR REBAR TABLE 6/S1, FLOOR TO SILL CONNECTION TABLE 1/S2, AND ANCHOR BOLT TABLE 2/S2USE MODIFIED CLEAR HEIGHT OF 9'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 8'-6" ANDUSE MODIFIED CLEAR HEIGHT OF 10'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 9'-6"(MAY REDUCE BACKFILL HEIGHT BY 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY AND CLAY SOILS)8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 3 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 16' 0" 3B3 1 Beam by others 6' 0" 1B4 1 Beam by others 4' 0" 1Pt1 2 Post by others 10' 0" 1UNEXCAVATEDUNEXCAVATEDDECK FRAMINGBY OTHERSFLOOR TRUSSESBY OTHERSFLOOR TRUSSESBY OTHERSSTAIRWAYMAX CLEAR SPANPt1Pt1B1B1B3B4B29' 0" 39' 0" 20' 8"18' 4"20' 10" 4' 8" 13' 6"42' 6"22' 6"65' 0" 56' 0" 13' 6"9' 0" 13' 10"ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B2 1 Beam by others 4' 0" 1DECK FRAMINGBY OTHERSB1B239' 0" 20' 8"18' 4"9' 0" ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2DECK FRAMINGBY OTHERSB19' 0" 39' 0"20' 8"18' 4"Sheet: 4 of 4DWG: BasementFile: Clifton F402/F422By: Anthony EstevezDate: 6-23-17Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.1-25-19AE12-8-18AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.CLIFTON F422-A-GLD.R. HORTONBASEMENT HEADERSDESIGN = L/360FULL BASEMENT OPTIONLOOKOUT BEAMS/HDRSWALKOUT OPTIONFULL BASEMENT COPYRIGHT HANSON GROUP, LLC 2020©THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESMATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.DescriptionApril 17, 2020Project Number:Date:0.146S11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044F402/F422/3402A-GL ModelMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Ryan Mack6-16-2246673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUT FOUNDATIONSMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ONLY w/ OPTIONAL UPPER LEVEL)3S1REFERENCE PLANCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION5S1FRAMING DETAILS1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 5/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS2'-312"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)2'-312"±WITH 3RD STALL GARAGE OPTIONCONSTRUCTPORTAL FRAMEAS SHOWN IN 4/S1(4-FT)(4-FT) (4-FT) ONE-SIDED (4-FT) ONE-SIDED (4-FT) ONE-SIDED (3.5-FT)(3.5-FT)BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINE(5-FT)(5-FT)(5-FT)(5-FT)(5-FT)(5-FT)(5-FT) (4-FT)(4-FT)(4-FT)(3.5-FT)(8-FT)(12-FT)ONE-SIDEDBRACED WALL LINE BRACED WALL LINE BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINEPROVIDE TOP OF WALLCONNECTIONS SHOWNFOR BRACED WALLPANELS ALONG INDICATEDPORTION OF WALL(8-FT)BRACEDWALL LINE(3.5-FT)(10-FT)(4-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINE(10-FT)(4-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINE(4-FT)PROVIDE TOP & BOTTOMOF WALL CONNECTIONSSHOWN FOR BRACED WALLPANELS ALONG INDICATEDPORTION OF WALLSCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY AND DECK ARE CONSIDERED TO BE PRIMARILY OPEN, NON-ESSENTIAL PORTIONS OF THE STRUCTURE ANDARE EXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS AND TENSION CONNECTIONS AT LEDGERS.(3.5-FT)(3.5-FT)Plan Changes6-16-221 Project Number:Date:1Sheets: ofI hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota.Print Name:Signed: License Number:Date:F1Ryan Mack466733407 Kilmer Lane NorthSuite 4Plymouth, MN, 55441Tel 612-708-3572www.hansongroupmn.comCOPYRIGHT HANSON GROUP LLC 2021©Project:Client:RevDescriptionDateJuly 21, 20210.1461PLANS SHOWN LIGHT INBACKGROUND ARE FORLOCATION REFERENCEONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHTMAY NOT NECESSARILYSUPPORT THE HANSONGROUP'S DESIGN.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044F422 ModelsAll ElevationsMN ConstructionPARTIAL FOUNDATION PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1F1REFERENCE PLANSCOPEDESIGN AND DETAILING OF A RETAINING WALL TYPE STAIRWAYFOUNDATION WALL FOR A SINGLE FAMILY RESIDENCE.CONSTRUCTION IS TO BE DONE IN ACCORDANCE WITH THESEDRAWINGS AND STANDARD INDUSTRY PRACTICE.GENERAL NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TOHOUSE PLANS FOR MORE INFORMATION.2.THE HANSON GROUP'S ENGINEERING IS LIMITED TO THEITEMS LISTED IN THE PROJECT SCOPE ABOVE. THE DESIGNOF THE REMAINING HOME IS BY OTHERS.3.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONSAND CONDITIONS BEFORE PROCEEDING WITH WORK. NOTIFYTHE HANSON GROUP IF DISCREPANCIES ARISE.4.DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, &INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE INACCORDANCE WITH THE CODE.5.INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILLPLATE AS WELL AS AN ANCHOR WITHIN 12" OF EACH END ASAPPLICABLE.6.BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BARDIAMETERS. PROVIDE 48" MATCHING HOOK BARS FOR ALLHORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.7.CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN APLUMB WALL ALIGNMENT. RETAINING WALL FOUNDATIONSRELY ON SLAB-ON GRADE FOR LATERAL RESISTANCE.ADEQUATE TEMPORARY BRACING IS BY OTHERS UNTIL SLABIS IN PLACE AND FULLY CURED. WALL SECTION 2F1 RETAINING WALL TYPESTAIRWAY FOUNDATION WALL(3) #4 LONGITUDINAL BARSAT TOP OF FOOTING#4 HORIZ. BARS@ 24" O.C.8" MIN. C.I.P.CONCRETE WALLVERTICAL BAR OPTIONS:#5 BARS @ 24" O.C.OR #6 BARS @ 36" O.C.#4 BARS @ END &BEND OF HOOK5'-0" HOOK OPTIONS:#5 HOOKS @ 12" O.C. OR#6 HOOKS @ 18" O.C.TRANSVERSE BARS OPTIONS:#5 BARS @ 24" O.C. OR#6 BARS @ 36" O.C.10" THICK C.I.P.CONCRETE FOOTING1'-6"3'-6"2" TO VERTICAL BARS & HOOKS1'-6"4'-0"2" 3" 8'-4" MAX.SLAB-ON-GRADE12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 48" O.C. MAX. OR EQUIV.FRAME WALL ABOVESLAB-ON-GRADE &INSULATION BY OTHERS6" MIN. STEM WALL1Foundation Change7-15-22MATERIALSCONCRETE FOOTINGS: F'c = 5,000 PSI @ 28 DAYS (OR 3,000 PSI WITHAN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST EQUIVALENT TO 5,000 PSI CONCRETE)CONCRETE WALLS: F'c = 3,500 PSI @ 28 DAYSREINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60AGGREGATE: FOOTINGS - 112" MAX WALLS/SLABS- 34" MAXON-SITE SOIL:ANY OF THE FOLLOWINGSAND (TYPE I) geq = 30 PSF/FT (ACTIVE)SANDY CLAY (TYPE II) geq = 45 PSF/FT (ACTIVE)CLAY (GROUP III) geq = 60 PSF/FT (ACTIVE)ALLOWABLE SOILBEARING PRESSURE: 2,000 PSF (ASSUMED)LOADSROOF LIVE LOAD: 35-42 PSF (SNOW)ROOF DEAD LOAD:15 PSFFLOOR LIVE LOAD:40 PSFFLOOR DEAD LOAD:15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODES2020 MINNESOTA RESIDENTIAL CODE2ALONGSTAIRWAYF1 7-15-22 Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 F422A - Clifton - Walkout HVAC Load Calculations for D.R. Horton 20860 Kenbridge Ct. #100 Lakeville, MN 55044 Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-319-4200 Monday, March 23, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating F422A - Clifton - Walkout Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:F422A - Clifton - Walkout Designed By:Jake Ryan Project Date:3/23/2020 Project Comment: Client Name:D.R. Horton Client Address:20860 Kenbridge Ct. #100 Client City:Lakeville, MN 55044 Client Phone:952.985.7272 Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-319-4200 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Southeast Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:942 CFM Per Square ft.:0.252 Square ft. of Room Area:3,731 Square ft. Per Ton:1,732 Volume (ft³):31,714 Building Loads Total Heating Required Including Ventilation Air:44,103 Btuh 44.103 MBH Total Sensible Gain:20,720 Btuh 80 % Total Latent Gain:5,129 Btuh 20 % Total Cooling Required Including Ventilation Air:25,849 Btuh 2.15 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. D:\F422 - Clifton - Walkout - Heat calc\F422 Walkout Heat Calc.rh9 Monday, March 23, 2020, 4:54 PM NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Ryan Klika 5/17/23 X PM