Loading...
HomeMy WebLinkAboutLA212747-17731 Embers Ave - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND 4:126126:1212126661216' x 8' STEEL RAISED PANELGARAGE DOOR9' x 8' STEEL RAISED PANELGARAGE DOOR1'-6"ARCHITECTURAL SHINGLES1'-6"1'-6"1'-6"1'-6"1'-6"VINYL BOARDAND BATTENVINYL SIDING AND CORNERS4:1216PRELIM. - 04/12/23RESIDENCE FOR: MAGNIFY SPEC HOUSE 17731 EMBERS AVE LAKEVILLE MN 55044FRONT ELEVATION 1/4" = 1'-0"NOTES:1.) ELEVATIONS ARE A ARTIST RENDERING ONLY, ACTUAL ELEVATION MAY VARY2.) ALL OVERHANGS SHALL BE 1'-6" TYPICAL UNLESS NOTED OTHERWISE3.) ALL RAKES SHALL BE 1'-6" TYPICAL UNLESS NOTED OTHERWISE4.) ALUMINUM FASCIA AND SOFFITS ON ALL SIDES5.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESS OTHERWISE NOTED1ST FLOOR1150 SQ. FT.2ND FLOOR1273 SQ. FT.TOTAL2423 SQ. FT.BSM'T-UNFIN.1150 SQ. FT.GARAGE 751 SQ. FT.TOTAL4324 SQ. FT.REVISED - 05/31/23Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode06/01/2023dmathews 6:121246:121266121'-6"VINYL SIDING AND CORNERSARCHITECTURAL SHINGLES1'-6"1'-6"2'6:126:121266121'-6"1'-6"VINYL SIDING AND CORNERSARCHITECTURAL SHINGLES1'-6"DECK LEDGER6ARCHITECTURAL SHINGLES126:121'-6"1'-6"VINYL SIDING AND CORNERS1'-6"1'-6"6:126:126:126:126:124:126:122'26LEFT ELEVATION 1/8" = 1'-0"RIGHT ELEVATION 1/8" = 1'-0"REAR ELEVATION 1/8" = 1'-0"ROOF PLAN 1/8" = 1'-0" FL DR3'-1112"16'2'-6"41'-10"32'49'-10"45'-10"9'-2"3'-1014"18'-114"12'-814"3'-1014"15'-534"1'-10"2'-6"9'4' 21'-10"24'2'17'-10"49'-10"45'-10"10'-2"UNEXCAVATED8'-4" H X 8" W POURED CONCRETE FROST WALLSILL SEALER1 TREATED PLATEON 16" X 8" CONCRETE FOOTINGSREBAR PER ENG. REQUIREMENTS FUTUREBEDROOM39'-8"6'-7" VSL 6'-0"X 4'-0"3-2X10UNFINISHEDBASEMENT3-2X103'-4" H X 8" W POURED CONCRETE FROST WALLSILL SEALER1 TREATED PLATEON 16" X 8" CONCRETE FOOTINGSREBAR PER ENG. REQUIREMENTS8'-4" H X 8" W POURED CONCRETE FROST WALLSILL SEALER1 TREATED PLATEON 16" X 8" CONCRETE FOOTINGSREBAR PER ENG. REQUIREMENTS8'2'6'2'4'-1"UNEXCAVATEDVPD 6'-0"X 6'-8"SUMP3-2X12(FLUSH)2-2X1018" FLOOR TRUSSES SPACED 19.2" O.C. 18" FLOOR TRUSSES SPACED 19.2" O.C.2X6 BEARING WALL STUDS @ 16" O.C.- STACK STUDSSTORAGE2X6 BEARING WALL STUDS @ 16" O.C.18" FLOOR TRUSSES SPACED 19.2" O.C.2-2X10MECHANICALBATHWSWHFURNACE11'-614"6'-7"4' W.S.P.4' W.S.P.4' W.S.P.SMOKEFANSMOKE7'-534"3'-534"2'-6"2'-4"2'-6"2'-6"6'-0"5'-934"2'-5"1012"3'-612"12'-434"MIN. 15" FROM CL OF TOILET TOANY OBSTRUCTION. 24" MIN. INFRONT OF TOILETCL6'-3"4'STEP CONCRETE AS NEEDEDSTEP CONCRETE AS NEEDED2"8"-2' X 2' PAD FOOTING1'-4"1'-4" 1'-4"36BASEMENT PLAN 1/4" = 1'-0"8'-4" POURED FOUNDATIONNOTES:1.) ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2X10 UNLESS OTHERWISE NOTED2.) STAIR TREAD CUT SHOWN AT 10"- 7 3/4 MAX RISE3.) ALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF CONCRETE WALL UNLESS OTHERWISE NOTED4.) ALL INTERIOR DIMENSIONS ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED5.) GARAGE WALLS ARE 2X6 STUDS UNLESS OTHERWISE NOTED6.) TRUSS AND FLOOR JOIST MANUFACTURER TO VERIFY SIZE AND SPACING OF JOIST AND TRUSSES7.) 4" RETURNS ON ALL DOORS UNLESS OTHERWISE NOTED8.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESS OTHERWISE NOTEDUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 2'-4"18" FLOOR TRUSSES SPACED 19.2" O.C. 2'-6" 2'-0"3'-0"2'-0"2'-0"2'-6"DWKITCHEN4'2'-4"5'10'18'4'-1112"50'32'3'-1014"7'-812"3'-0"18" FLOOR TRUSSES SPACED 19.2" O.C.14'-214"9'-1014"10'6'-912"40'9'-2"50'36' 46' 22'24' 46'1'2'-1112"5'-012"2'3'-012"9'2'-6"2'-6"6'-414"16'15'-734" 3'-1014"12'-734"5'-212"16' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOORW.I.C.(LVP)DININGROOMGREATROOMPANTRY1/2BATH(LVP)FOYER3 CAR GARAGEOFFICE/STUDYMUDROOM(LVP)9' x 8' STEEL RAISED PANELINSULATED OH GARAGE DOOR9'-514"3'-0"6'-414"5'-634"4'-412"5'-812"COVEREDPORCHVSL 6'-0"X 5'-0"VFIX 3'-0"X 4'-0"VPD 6'-0"X 6'-8" VSH 3'-0"X 3'-0"VSL 8'-0"X 5'-0"2-2X102-2X102-2X10 3'-814"2'-014"3-2X104'-5"2- 11 7/8 LVLFLOOR LINE ABOVE16' -DECK LEDGER3'-6"3'-6"3'-1012"ROOF TRUSSESSPACED 24" O.C.REF2X6 BEARING WALL STUDS @ 16" O.C.-STACK STUDS3-2X12(FLUSH)FLOOR LINE ABOVE2-2X122X6 BEARING WALLSTUDS @ 16" O.C.6'-234"18" FLOOR TRUSSES SPACED 19.2" O.C.1'10'1'6'3-2X122X6 STUD WALL 16" O.C.-STACK STUDS11'-814"6'-7"FAN4' W.S.P.4' W.S.P.10' CS-W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P. 14'-5" CP-W.S.P.3' CS-W.S.P4' CS-W.S.P.4' W.S.P.2' C.S.-P.F.2' -6" C.S.-P.F.2' -6" C.S.-P.F.SMOKECL MIN. 15" FROM CL OF TOILET TOANY OBSTRUCTION. 24" MIN. INFRONT OF TOILET1'-514"1' X 4' MECH. CHASE2'-7" 3'-0" BENCH2X4 STUD WALL2X4 STUD WALL2X4 STUD WALL2X4 STUD WALLFIRE PLACECTR ON WALL2'-734"2'-1012"1'-6"2-2X102-2X10 16"C.S.-P.F.2'-7"2'-7"TRANSOM3'-0"X 1'-6"TRANSOM3'-0"X 1'-6"5'5'-514"3' CS-W.S.P. 4' GB 46FIRST FLOOR 1/4" = 1'-0"9' CEILING @ FIRST FLOORNOTES:1.) ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2X10 UNLESS OTHERWISE NOTED2.) STAIR TREAD CUT SHOWN AT 10"- 7 3/4 MAX RISE3.) ALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING UNLESS OTHERWISE NOTED4.) ALL INTERIOR DIMENSION ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED5.) GARAGE WALLS ARE 2X6 STUDS UNLESS OTHERWISE NOTED6.) TRUSS AND FLOOR JOIST MANUFACTURER TO VERIFY SIZE AND SPACING OF JOIST AND TRUSSES7.) 4" RETURNS ON ALL DOORS UNLESS OTHERWISE NOTED8.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESS OTHERWISE NOTEDBWPsAboveBWPsAbove 6'-512"3'-412"2'-6"2'-6"2'-6"DRYER2'-6"2'-4"2'-6"5'-834"6'-0"6'-214"7'-914"12'-4"3'-914"12'-412" 15'-234"3'-214"21'-6"11'-914"50'15'-1034"6'-134"48'8'-112"10'6'-012"6'-214"2'-4"38'3'-914"5'-834"5'-414"6'-214"10'10'-434"6'-834"8'-534"21'-6" 3'-834" 48' 26'-6"10'BEDROOM 3(CARPET)MASTER BEDROOM(CARPET)BEDROOM 4(CARPET)W.I.C.(CARPET)BEDROOM 2 (CARPET)W.I.C(CARPET)W.I.C.(CARPET)LAUNDRY(VINYL)BATH5'-012"8'-4"11'-834"2'-6"3'-6" 8'-914"5'-5"VFIX 3'-0"X 4'-0"VSL 6'-0"X 4'-0" VSL 6'-0"X 4'-0"VSL 6'-0"X 4'-0"2-2X102-2X102-2X10 2-2X10WOOD RAILING2-2X104'-934"4'-5" VSL 6'-0"X 4'-0"ROOF TRUSSES SPACED 24" O.C. ROOF TRUSSES SPACED 24" O.C. ROOF TRUSSES SPACED 24" O.C.ROOF TRUSSESSPACED 24" O.C.40'2'-6"6'-012"2X6 WETWALL STUDS 16" O.C. VSH 3'-0"X 4'-0"3'-212"3'-614"2-2X10TUBLINEN2'-0"TUB/SHOW2'-4"11'-314"3'-8"6'-812"2'-4"2'-4"MIN. 15" FROM CL OF TOILET TOANY OBSTRUCTION. 24" MIN. INFRONT OF TOILET4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P. 4' W.S.P.4' W.S.P.3' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.4' W.S.P.FANFANSMOKESMOKESMOKESMOKESMOKE/COCLCLMIN. 15" FROM CL OF TOILET TOANY OBSTRUCTION. 24" MIN. INFRONT OF TOILET2'-4"FAN2'-6"18"X18" CORNER BENCHCOUNTERLINEN2'-0"SHOWER CONTROLSRAIN SHOWER HEADBUILT-IN SHELVESIN SHOWER2'-412"4'-934"MASTERBATH7'-612"4' W.S.P.4' W.S.P.56SECOND FLOOR 1/4" = 1'-0"NOTES:1.) ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2X10 UNLESS OTHERWISE NOTED2.) STAIR TREAD CUT SHOWN AT 10"- 7 3/4 MAX RISE3.) ALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING UNLESS OTHERWISE NOTED4.) ALL INTERIOR DIMENSION ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED5.) GARAGE WALLS ARE 2X6 STUDS UNLESS OTHERWISE NOTED6.) TRUSS AND FLOOR JOIST MANUFACTURER TO VERIFY SIZE AND SPACING OF JOIST AND TRUSSES7.) 4" RETURNS ON ALL DOORS UNLESS OTHERWISE NOTED8.) ALL EXTERIOR SHTG. SHALL BE CONTINUOUS 7/16 STRUCTURAL WOOD SHTG. UNLESS OTHERWISE NOTEDGirderTemper if within 36"of landing floor.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). 3/4" T&G SUBFLOORRIM JOISTHORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X6 STUDS @ 16" O.C.R-21 INSULATION1/2" GYP. BOARD5/8" GYP. BOARD3/4" T&G SUBFLOORR-21 SPRAY FOAM5/8" GYP. BOARDRIM JOIST8'-4" X 8" POURED CONC. WALLW/ REBAR PER CODEGRADE16" X 8" CONC. FTGS2" RIDGID INSULWATER PROOFING3 1/2" CONC. SLAB OVER4" MIN. LAYER OF RIVER ROCKGRANULAR FILL4" DRAIN TILEW/SILT ROCK2 X 8 TREATED SILL PLATEALUM. FASCIAALUM. VENTED SOFFITASPHALT SHINGLES15# FELT1/2" SHEATHINGROOF TRUSSESR-50 INSULATIONENERGY HEEL612HORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X6 STUDS @ 16" O.C.R-21 INSULATION1/2" GYP. BOARD6"18" TRUSS SPACING BY MFG18" TRUSS SPACING BY MFG9'-118"8'-2"8'-118"R-21 SPRAY FOAM3 1/2" CONC. SLAB OVER4" MIN. LAYER OF RIVER ROCK2" RIDGID INSUL4" DRAIN TILEW/SILT ROCKHORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X8 STUDS @ 16" O.C.R-21 INSULATION6"GRADE3'-4" X 8" POURED CONC. WALLW/ REBAR PER CODE1- 2X8 TREATED SILL PLATE16" X 8" CONC. FTGSWATER PROOFINGGRANULAR FILL3'-6"1'-6"3/4" T&G SUBFLOOR5/8" GYP. BOARD9'-1 18"8'-1 18"GRADE6" 3'-6"BEDROOM 4BEDROOM 3GREAT ROOMOFFICE/STUDY8'-2"18" FLOOR TRUSSES SPACING BY MFG5/8" GYP. BOARD1'-6"R-50 INSULATIONENERGY HEEL6122'8 RISERS9 RISERS9 RISERSFUTURE REC ROOMSTORAGEALUM. FASCIAALUM. VENTED SOFFITASPHALT SHINGLES15# FELT1/2" SHEATHINGROOF TRUSSES3'6'18" FLOOR TRUSSES SPACING BY MFG3/4" T&G SUBFLOOR8 RISERS2X6 TREATED SILL PLATEFLUSH WITH CONCRETE WALL3'16X8 CONCRETE FOOTINGCONCRETE STOOP7/16 GREEN TREATED STRUCT.SHEATHING @ STOOP8'-012"2-2X10 HEADER2'18" TRUSS SPACING BY MFGHORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X6 STUDS @ 16" O.C.R-21 INSULATION1/2" GYP. BOARD3/4" T&G SUBFLOORHORIZ. LAP SIDINGWEATHER BARRIER7/16" STRUCT. SHEATHING2X6 STUDS @ 16" O.C.R-21 INSULATION1/2" GYP. BOARDR-38 FIBERGLASSINSULATION TIGHTTO SUBFLOOR18" RIM JOISTR-21 SPRAY FOAM INSULATIONWITH SOLID BLOCKING66TYP. WALL SECTION 1/2" = 1'-0"TYP. WALKOUT SECTION 1/2" = 1'-0"FULL SECTION 1/4" = 1'-0"TYPICAL CATILEVER DETAIL 1/2" = 1'-0"PASSIVE RADON SYSTEM3" MIN. ABS OR PVC GAS TIGHTPIPE FROM SUBSLAB TO MIN. 12"ABOVE ROOF. MUST BE RUN THRUCONDITIONED SPACEPIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE "T"FITTING(MIN. 10'-0" EACH WAY) INGRAVEL UNDER SLABEND OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE.END OF PIPE MUST ALSO BE MIN.10'-0" AWAY FROM ANY WINDOW OROTHER OPENING IN ADJOINING ORADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFTAROUND PIPE IN ATTIC SPACE TOADD FAN. SPACE MUST BE MIN.24" CENTERED ON AXIS OF PIPE W/MIN. 3'-0" VERTICAL SPACEA SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION THIS INCLUDESINTERIOR FOOTINGS AND OTHERBARRIERS IF AIRFLOW HAS BEENESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH "RADONREDUCTION SYSTEM" Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-10 X R-10 X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X Not applicable, all ducts located in conditioned space R8 X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60,000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's " round duct OR " metal duct X Not required per mech. code Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's 6 " round duct OR 5 " metal duct Output in Tons:2.550 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM 585 85 Capacity continuous ventilation rate in cfms: powder, main, master PROG50 BA13NA024 Model Heating System Nat Gas Bryant Interior Interior Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type RHEEM Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13SEER /EER 912SD060 Manufacturer Bryant Nat GasTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.32 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 51,675 Heating Gain Cooling Load 85 170 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation Heating Loss Combustion Air Select a Type Location of duct or system: 24,167 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor Silver Tree Plumbing and Heating MN License Number MB005441 City Mailing Address of the Dwelling or Dwelling Unit THERMAL ENVELOPE Foam Open Cell Wall Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.32 Appliances Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM R10 ExteriorNon or Not Applicable Cooling System Builders Associaton of Minnesota version 101014 TOTAL INPUT OF APPLIANCES1, THOUSANDS OF Btu/hr (kW) REQUIRED FREE AREA OF AIR-SUPPLY OPENING OR DUCT, SQUARE INCHES (sq mm) ACCEPTABLE APPROXIMATE ROUND DUCT EQUIVALENT DIAMETER2, INCH (mm) 25 (8)7 (4,500)3 (75) 50 (15)7 (4,500)3 (75) 75(23)11 (7,000)4 (100) 100 (30)14 (9,000)4 (100) 125 (37)18 (12,000)5 (125) 150 (45)22 (14,000)5 (125) 175 (53)25 (16,000)6 (150) 200 (60)29 (19,000)6 (150) 225 (68)32 (21,000)6 (150) 250 (75)36 (23,000)7 (175) 275 (83)40 (26,000)7 (175) 300 (90)43 (28,000)7 (175) 325 (98)47 (30,000)8 (200) 350 (105)50 (32,000)8 (200) 375 (113)54 (35,000)8 (200) 400 (120)58 (37,000)9 (225) 1. For total inputs falling between listed capacities, use next largest listed input. 2. If flexible duct is used, increase the duct diameter by one inch. * *Flexible duct shall be stretched with minimal sags. TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING 400,000 Btu/hr BTU Amount for Non-direct vent appliances_____________________ 1 2 3 4 5 6 2 Conditioned space1 (in sq. ft.) Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130-65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113 1. Conditioned space includes the basement and conditioned crawl spaces. 2. If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation R403.5.2 R403.5.2 Total Ventilation rate. The mechanical ventilation system shall rovide sufficient outdoor air to equal the total ventilation rate average for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and square footage of conditioned space, including the basement and conditioned crawl spaces. For the purposes of Table R403.5.2 and Section R403.5.3, the following applies: a. Equation R403.5.2 Total ventilation rate: Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms +1)) b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventiation rate/2 Amount Total _________________________ Amount Continuous____________________ TABLE R403.5.2 NUMBER OF BEDROOMS VENTILATION REQUIREMENTS ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD 1. Use the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) b) conditioned floor area (sf) (including unfinished basements) Estimated House Infiltration (cfm): [1a x 1b] 2. Exhaust Capacity a) clothes dryer b) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) c) 80% of next largest exhaust rating (cfm):not applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm): [2a+2b+2c] 3. Makeup Air Requirement a) Total Exhaust Capacity (from above) b) Estimated House Infiltration (from above) Makeup Air Quality (cfm): [3a - 3b] (if value is negative, no makeup air is needed 4. For Makeup Air Opening Sizing, refer to Table 501.4.2. A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Table 501.4.1 Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units Choose Which Applies TYPE OF OPENING ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD PASSIVE MAKEUP AIR OPENING DUCT DIAMETERE,F,G OR SYSTEM (cfm)(cfm)(cfm)(cfm)(inches) Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 144-195 100-135 62-83 8 Passive opening with motorized damper 318-419 196-258 136-179 84-110 9 Passive opening with motorized damper 420-539 259-332 180-230 111-142 10 Passive opening with motorized damper 540-679 333-419 231-290 143-179 11 Powered makeup airH >679 >419 >290 >179 Not applicable A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (ther than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combution appliace information: Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: Btu/hr (Not fan Assisted) & Power Vent Water Heater: Draft Hood Fan Assisted Direct Vent Input: Btu/hr ( Not fan Assisted) & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 Step 3: Determine air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) RVFA: ft3 Total Btu/hr input of all non-fan-assisted appliances Input: Btu/hr Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) RVNFA: ft3 Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio RF = - = Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 / Btu/hr per in 2 = in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 x Minimum CAOA = in 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. CAOA = IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Known Air Infiltration Rate (KAIR) Method (ft3) Input Rating Standard Method Fan Assisted Non-Fan-Assisted (Btu/hr) (ft3) 19941 to Present Pre 19942 19941 to Present Pre 19942 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8,625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,763 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-May-22 11:36:10Right-Suite® Universal 2022 22.0.01 RSU64702 Page 1 ...\Wrightsoft HVAC\KJ Walk- Lakeville 2 story.rup Calc = MJ8 Front Door faces: E Job:Load Short Form 5/22/23Date:Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silvertreepandh.com Web: www.silvertreepandh.com Project Information KJ Walk- Lakeville 2 StoryFor: Design Information InfiltrationClgHtg SimplifiedMethod88-15Outside db (°F)Semi-tightConstruction quality7270Inside db (°F) 1 (Semi-tight)Fireplaces1685Design TD (°F) M-Daily range 5030Inside humidity (%)5030Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade Bryant Legacy Line 92 Gas Furn...Trade 14 SEER ACModel912SD42060E17CondBA14NA03000L0A0 AHRI ref 0 Coil CNPVT3617ALA+912SD42060E17 AHRI ref 0Efficiency92.1 AFUE Efficiency 12.5 EER, 15 SEER Heating input Btuh60000 Sensible cooling Btuh22240 Heating output Btuh56000 Latent cooling Btuh5560 Temperature rise °F57 Total cooling Btuh27800 Actual air flow cfm927 Actual air flow cfm927 Air flow factor cfm/Btuh0.020 Air flow factor cfm/Btuh0.043 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.85 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 1051 13286 4075 261 174 Room2 1051 16788 11116 330 474 Room4 1051 14762 6124 290 261 Room5 54 2295 414 45 18 Entire House 3206 47131 21729 927 927 Other equip loads 4545 285Equip. @ 0.93 RSM 20429 Latent cooling 3738 TOTALS 3206 51675 24167 927 927