Loading...
HomeMy WebLinkAboutLA210054 Revised Structural Page6-6-232Longer LVL Beam©DateRevisionLennar Corporation16305 36th Ave N. Suite 600Plymouth, MN 55446PLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DescriptionCOPYRIGHT HANSON GROUP, LLC 2020THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.FRAMING NOTES1.ALL HEADERS ARE TO BE MINIMUM (2) 2x10 LUMBER UNLESS NOTED OTHERWISE. (2) 2x10 MEMBERS SHOWNMAY BE SUBSTITUTED WITH (2) 1¾" x 7¼" LSL AS REQUIRED.2.ALL DIMENSION LUMBER HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE BEARING STUD AT EACH ENDAND TWO AT INTERMEDIATE SUPPORTS. ALL 2-PLY LSL/LVL AND GIRDER TRUSS BEAMS AND HEADERS ARE TOHAVE A MINIMUM OF TWO BEARING STUDS AT EACH END AND AT INTERMEDIATE SUPPORTS. 3-PLY LSL/LVLAND GIRDER TRUSS MEMBERS ARE TO HAVE A MINIMUM OF THREE BEARING STUDS AT EACH END AND ATINTERMEDIATE SUPPORTS. ADDITIONAL BEARING STUDS ARE NOT REQUIRED FOR LVL/LSL SUBSTITUTED FORSTANDARD SAWN LUMBER. ALL BEARING ABOVE IS UNLESS NOTED OTHERWISE ON PLANS. TRUSS SUPPLIERIS TO VERIFY GIRDER TRUSS BEARING LENGTH AND SUPPORT REQUIREMENTS. BEARING ENHANCERS AREBY THE SUPPLIER.3.ALL HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE FULL HEIGHT KING STUD AT EACH END.EXTERIOR OPENINGS GREATER THAN SIX FEET IN WIDTH ARE TO HAVE A MINIMUM OF TWO FULL HEIGHT KINGSTUDS AT EACH END, EXCEPT AT TALL WALLS AS NOTED. EXTERIOR OPENINGS GREATER THAN TEN FEET INWIDTH ARE TO HAVE A MINIMUM OF THREE FULL HEIGHT KING STUDS AT EACH END, EXCEPT AT TALL WALLSAS NOTED. FOR CONTINUOUS BEAM CONDITIONS, SPAN IN DETERMINING NUMBER OF KING STUDS IS THEFULL LENGTH OF THE HEADER.4.ALL CONNECTIONS ARE TO BE MADE WITH ADEQUATE SIMPSON, USP OR EQUAL JOIST HANGERS, CLIPS, POSTCAPS, AND POST BASES.5.CONNECT MULTIPLE MEMBER LSL/LVL'S TOGETHER IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS.6.VERIFY DROPPED VERSUS FLUSH BEAM CONDITIONS WITH HOUSE PLANS.7.ALL OTHER FASTENERS TO BE IN ACCORDANCE CODE TABLE R602.3(1).8.ALL STUD PLIES IN BUILT UP COLUMNS AND AT INTERMEDIATE STUD FRAMING TO BE FASTENED TOSHEATHING / GYP BOARD AS NOTED BELOW (12" O.C. MAX. AT EXTERIOR AND 16" O.C. MAX. AT INTERIOR).9.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.,WHICH MEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 (2x4 AT GARAGE) STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C ATPANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.10.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C. (24" O.C. AT NON-BEARING WALLS)B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C.MAX. OR TYPE S/W WALLBOARD SCREWS @ 16" O.C. (12" O.C. w/ 24" STUD SPACING) MAX. (58" MINIMUMSTUD PENETRATION)11.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS.12.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIPS OR EQUIVALENT AND (4) 0.131"Ø x3" TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.D.LATERAL BRACING OF TOP OF GABLE END WALLS IN ROOF SPACE IS TO BE PROVIDED BY TRUSSSUPPLIER.13.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12)0.131"Ø x 3" NAILS IN LAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3"FACE NAILS.14.ALL BEARING POINT OR POST LOADS ARE TO BE BLOCKED SOLID TO THE FOUNDATION.15.STEEL BEAMS ARE TO HAVE SOLID 2 x MINIMUM TOP PLATE FASTENED WITH ½" DIAMETER BOLTS STAGGEREDEACH SIDE OF WEB AT 48" ON CENTER MAX. WIDTH TO MATCH BEAM. INCREASE PLATE THICKNESS ASREQUIRED FOR TOP FLANGE HANGERS. BEAM TOP FLANGE / PLATE TO BE BRACED LATERALLY BY FLOORSYSTEM AT 48" O.C. MAX AND AT ENDS TYP. FOR FLUSH FLOOR FRAMING CONNECTIONS, BLOCK WEB SPACESOLID w/ LUMBER TIGHT BETWEEN FLANGES AND BOLT THROUGH WEB w/ 12"Ø BOLTS AT 24" O.C. STAGGERED.16.CUT PSL POSTS TO FIT. DO NOT BLOCK WITH WOOD PLATE MATERIAL OR CRUSHING MAY OCCUR. FASTENSTEEL BEAMS TO PSL POSTS w/ (4) 516" x 6" STRUCTURAL WOOD SCREWS. AT BOTTOM, PSL TO BEARDIRECTLY ON CONCRETE. IF UNTREATED, WRAP BOTTOM w/ MEMBRANE.17.TALL WOOD WALL FRAMING IS DESIGNED TO AN H/180 DEFLECTION CRITERIA AT A MINIMUM.18.COVERED ENTRY PORCH IS CONSIDERED BY THE HANSON GROUP TO BE A NON-ESSENTIAL PRIMARILY OPENSTRUCTURE NOT PART OF THE MAIN WIND FORCE RESISTING SYSTEM. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS.HARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTMATERIALSCONCRETE FOOTINGS: F'c = 5,000 PSI @ 28 DAYS(OR 3,500 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATERAND VAPOR RESISTANCE AT LEASTEQUIVALENT TO 5,000 PSI CONCRETE)AGGREGATE: FOOTINGS - 112" MAX.REINFORCING STEEL: ASTM A615 GRADE 60ALLOWABLE SOILBEARING PRESSURE: 2,000 PSF (ASSUMED)WALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL STUDS:112" WIDTH - 1.3E OR BETTERLSL BEAMS:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERPSL:1.8E OR BETTERGLULAM:SYP 26F4V OR BETTERSTRUCTURAL STEEL:CHANNELS/MISC - ASTM A36 (Fy = 36KSI)TUBES - ASTM A500 Gr. B (Fy = 46 KSI)W SECTIONS - ASTM A992 (Fy = 50 KSI)ABBREVIATIONSTYP.=TYPICALSIM.=SIMILARU.N.O.= UNLESS NOTED OTHERWISEO.C.= ON CENTER= CONTINUOUS OVERLOADSROOF LIVE LOAD: 35 PSF (SNOW)ROOF DEAD LOAD:15 PSFFLOOR LIVE LOAD:40 PSFFLOOR DEAD LOAD:15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODES2020 MINNESOTA RESIDENTIAL CODEPROJECT SCOPEDESIGN OF CONCRETE PAD AND STRIP FOOTINGS, BEAM AND HEADER FRAMING, AND THE MAIN WINDFORCE RESISTING SYSTEM FOR ASINGLE FAMILY RESIDENCE. CONSTRUCTION IS TO BE DONE IN ACCORDANCE WITH THESE DRAWINGS, STANDARD INDUSTRY PRACTICE,AND THE REQUIREMENTS OF THE CODE.GENERAL NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS FOR MORE INFORMATION.2.THE HANSON GROUP'S SCOPE IS LIMITED TO THE DESIGN OF THE ITEMS LISTED IN THE PROJECT SCOPE ABOVE. DESIGN OF THEREMAINING HOME, INCLUDING ALL MANUFACTURER ENGINEERED PRODUCTS AND FOUNDATION WALLS, IS BY OTHERS.3.IT IS THE RESPONSIBILITY OF THE BUILDER TO PROVIDE ALL FUTURE PLAN OR FIELD CHANGES TO THE HANSON GROUP FOR REVIEW.IF FINAL TRUSS LAYOUTS VARY FROM THOSE SHOWN ON HOUSE PLANS, NOTIFY ENGINEER PRIOR TO CONSTRUCTION.4.ADEQUATE SHORING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR.5.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH WORK. NOTIFY THEHANSON GROUP IF DISCREPANCIES ARISE.6.MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR.FOUNDATION NOTES1.ALL FOUNDATION WALLS ARE TO BE STANDARD CONCRETE PER CODE, UNLESS NOTED OTHERWISE IN THESE DRAWINGS.2.DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCEWITH THE CODE.3.INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHOR WITHIN 12" OF EACH END AS APPLICABLE.4.CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT.INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN FRAMING NOTE 10, SPACED AT 4" O.C. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ FRAMING NOTE 9. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(3-FT)(3-FT)(2.5-FT)(2.5-FT)(4-FT)(4-FT)(4-FT) (4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(5-FT)(5-FT)(5-FT)(6-FT)(5-FT) (4-FT)(4-FT)(4-FT)(3.5-FT)(7.5-FT)(5-FT)(12-FT)INDICATES SPANDIRECTION OFTRUSSES BYSUPPLIER TYP.(2) 2x106x6 POST w/ STANDARDPOST BASE & CAP TYP.(3) 2x10(2) 2x10(2) 2x10 (2) 2x12(2) 2x4BEARINGSTUDSINDICATES SPANDIRECTION OFTRUSSES BYSUPPLIER TYP.PROVIDE TOP & BOTTOM OFWALL CONNECTIONS SHOWN FORBRACED WALL PANELS ALONGINDICATED PORTION OF WALLINDICATES CONTINUOUSHEADER OVER MIN. (3) 2x6BEARING STUDS TYP. U.N.O.INDICATES CONTINUOUSHEADER OVER MIN. (3) 2x6BEARING STUDS TYP. U.N.O.STAIR EXTERIOR 18'-7"± TALL WOOD WALLTO TO BE CONSTRUCTED AS FOLLOWS:·2x6 LSL @ 16" O.C. TYPICAL FULL HEIGHTWALL FRAMING (BALLOON FRAMED)·PROVIDE 2x6 BLOCKING BETWEENSTUDS AT INTERVALS NOT TO EXCEED10-FT ALONG HEIGHT OF WALL·WALL TOP & BOTTOM PLATES MAY BESPF/SYP MATERIALPROVIDE MIN. 16" x 8"CONCRETE STRIPFOOTINGS UNDER ALLFOUNDATION WALLS &INTERIOR BEARING WALLS(2) 16" LVL OR (3) 14" LVL OR W10x19(2) 14" LSLEXTENDED HEADER(2) 1178" LSLEXTENDED HEADERUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)3S3REFERENCE PLANPLAN NOTES:·ALL REMAINING BEAMS AND HEADERS NOT SPECIFIED ARE TO BE MIN.(2) 2x10 OR AN ALLOWABLE SUBSTITUTE LISTED IN THE FRAMING NOTES.·PROVIDE (2) 2x6 BEARING STUDS AT ENDS OF ALL GIRDER TRUSSES U.N.O.·SEE FRAMING NOTES FOR BEAM AND HEADER SUPPORT REQUIREMENTS.CONCRETE PAD FOOTING SCHEDULEMARKFOOTING SIZEREINFORCEMENT EACH WAYF1NOT USEDNOT USEDF2-OPTION 12'-6" x 2'-6" x 12"NONEF2-OPTION 22'-6" x 2'-6" x 8"#5 BARS @ 12" O.C.LOCATE REINFORCEMENT 3" FROM THE BOTTOM OF FOOTING(4) 2x6BEARINGSTUDSF2MAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)2S3REFERENCE PLANPLAN NOTES:·ALL REMAINING BEAMS AND HEADERS NOT SPECIFIED ARE TO BE MIN.(2) 2x10 OR AN ALLOWABLE SUBSTITUTE LISTED IN THE FRAMING NOTES.·PROVIDE (2) 2x6 BEARING STUDS AT ENDS OF ALL GIRDER TRUSSES U.N.O.·SEE FRAMING NOTES FOR BEAM AND HEADER SUPPORT REQUIREMENTS.HOUSE FOUNDATION PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1S3REFERENCE PLANWITH 3RD STALL GARAGE OPTIONWITH 3RD STALL GARAGE OPTIONWITH 2' GARAGE EXTENSIONWITH 2' GARAGE EXTENSIONSEE 2/S3 FORTALL WALLFRAMING(2) 2x10 (3) 2x4BEARINGSTUDS(3) 2x4BEARINGSTUDS(2) 2x106x6 POST w/ STANDARDPOST BASE & CAP TYP.(3) 2x10CONSTRUCTPORTAL FRAME ASSHOWN IN 1/S4Project Number:Date:S31Sheets: of2Print Name:Signed: License Number:Ryan Mack46673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.Sequoia/EO90 Model"E" ElevationMinnesota ConstructionOctober 12, 20200.585(6-FT)DASHED-DOT LINEINDICATES PRIMARYGIRDER TRUSS TYP.CONSTRUCTPORTAL FRAME ASSHOWN IN 1/S4(5-FT)DASHED-DOT LINEINDICATES PRIMARYGIRDER TRUSS TYP.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.com6-6-23(2) 2x10 (2) 2x10 5-10-231Framing Changes(3) 18" LVL F2(4) 2x6BEARINGSTUDS4'-0" ACTUALDIMENSION4'-0" ACTUALDIMENSIONRevised LVL beamdue to wing wall onlybeing 4' out and not 5'as per original plan.