Loading...
HomeMy WebLinkAboutLA215303-APPROVED - 20230712_Winona Renewable Energy_5226 175th ST W_SM_UBuilder Report_RevEngineering Alliance, Inc https://www.eng-alliance.com 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757 13-July-2023 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87101 Tel: 505 242 6411 Attn.: Kevin Phan, Re: Project ID & Title: 3225973F, 5226 175th ST W The following calculations are for the Structural Engineering Design of the Photovoltaic Panels located at 5226 175th St W, Farmington, MN 55024 Please feel free to call for any questions or clarifications. Prepared By: Engineering Alliance, Inc Sugar Land TX Professional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Saddam Ahmad Date: License Number: 5538113-JUL-2023 Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 07/14/2023dpfannenstein Please provide a City Approved Plan and Permit Card on site accessible for Inspectors until final inspection LEGEND: Base System Part AccessoryBILL OF MATERIALS PART NUMBER PART TYPE DESCRIPTION QUANTITY UNIT PRICE (USD) TOTAL LIST PRICE (USD) 315246M Rail SM LIGHT RAIL 246" MILL 16 51.61 825.76 303019M Splice BND SPLICE BAR PRO SERIES MILL 8 6.05 48.40 302045M Mid Clamp UNIVERSAL AF SERIES MID CLAMP MILL 64 2.84 181.76 302050M End Clamp UNIVERSAL AF SERIES END CLAMP MILL 16 3.27 52.32 003250W Decking Screws #12-14 X 2.50 SCREW HDW SS SD (6 per Flashloc DUO)912 0.70 638.40 004275M Comp Roof Attachment FLASHLOC DUO MILL 152 10.22 1553.44 008009P Grounding Lug ILSCO LAY IN LUG (GBL4DBT) 4 7.54 30.16 008114M Retaining Clip MLPE MOUNT ASSY 36 2.42 87.12 U-BUILDER PROJECT REPORT APPLICATION VERSION: 6.0.5PROJECT VERSION: 0.0.33 PROJECT TITLE 5226 175th ST W PROJECT ID 3225973F LAST UPDATED Jul. 12, 2023 ORIGINALLY CREATED Jul. 12, 2023 NAME Winona Renewable Energy ADDRESS 5226 175th St W CITY, STATE Farmington, MN MODULE JA Solar JAM54S31 395/MR Designed by chandramohan.g@nuevo-sol.com SOLARMOUNT-LT JA Solar 36 - JAM54S31 395/MR 14.22 KW NOTE: Installation of the project is intended to happen within the year of project designed in UBuilder. If it's past one year please rerun the design or contact Unirac Engineering Services. This design is to be evaluated to the product appropriate Unirac Code Compliant Installation Manual which references International Building Code 2009, 2012, 2015, 2018 and ASCE 7-05, ASCE 7-10, ASCE 7-16 and California Building Code 2010, 2016. The installation of products related to this design is subject to requirements in the above mentioned installation manual. BASE SYSTEM PRICE $3300.08 $0.232 PER WATT ACCESSORIES PRICE $117.28 $0.008 PER WATT TOTAL PRICE $3417.36 $0.240 PER WATT QTYDETAILED PARTS DESCRIPTION Rail 315246M SM LIGHT RAIL 246" MILL Structural aluminum extrusion containing slots that accept module and roof attachment hardware, electrical bonding accessories, and splice bars. 16 Splice 303019M BND SPLICE BAR PRO SERIES MILL Mill finished aluminum extrusion for joining adjacent lengths of rail to one another. Includes pre-assembled bolts. Uses 1/2" socket for 1-tool system install. 8 Mid Clamp 302045M UNIVERSAL AF SERIES MID CLAMP MILL Universal Aesthetic Fastener (Mid), Universal for modules between 30-46mm and features twist and lock installation, 1 tool install, UL2703 integrated bonding, and low profile hardware and 1/2' module gap for optimal aesthetics. Made from Aluminum and Stainless Steel hardware. 64 End Clamp 302050M UNIVERSAL AF SERIES END CLAMP MILL Universal Aesthetic Fastener (End), Universal for modules between 30-46mm without the use of spacers or extra parts, Features twist and lock installation, 1 tool install, UL2703 integrated bonding, and low profile hardware for optimal aesthetics. Clamps can be placed anywhere on the rail and rail can be cut flush with the clamp for optimal aesthetics. Made from Aluminum and Stainless Steel hardware, Caps are PC/ASA. 16 Decking Screws 003250W #12-14 X 2.50 SCREW HDW SS SD (4 per Flashloc DUO) Number 12-14 X 2.50 screws for Direct-to-Deck attachment. One pack comes with 60 screws. 912 Comp Roof Attachment 004275M FLASHLOC DUO MILL Direct-to-deck and rafter attachment for composition shingle and rolled comp roofs featuring FlashLoc technology. Mill finish. 152 Grounding Lug 008009P ILSCO LAY IN LUG (GBL4DBT) For electrical bonding of PV modules and rails. Accepts 4-14 AWG copper wires. Tin plated copper body, 1/4" stainless steel fasteners. 4 Retaining Clip 008114M MLPE MOUNT ASSY MLPE MOUNT ASSY 36 ENGINEERING REPORT * Distributed Dead Load 2.68 psf * Average Roof Point Dead Load 13.34 lbs Plan Review TOTAL NUMBER OF MODULES 36 TOTAL KW 14.22 KW TOTAL MODULE AREA ~757 ft Loads Used for Design BUILDING CODE ASCE 7-16 BASIC WIND SPEED 109.00 mph GROUND SNOW LOAD 50.00 psf L-FOOT DIRECTION For ground snow loads >= 40.00 psf install the l-foot in upslope direction. See the high- snow attachment document above. SEISMIC, S 0.048 ELEVATION 921.00 ft RISK CATEGORY II WIND EXPOSURE C TOPOGRAPHICAL FACTOR, K 1.00 VELOCITY PRESSURE, Q 21.23 psf RISK CATEGORY II 2 S ZT Z Inspection PRODUCT SOLARMOUNT-LT MODULE MANUFACTURER JA Solar MODEL 36 - JAM54S31 395/MR MODULE WATTS 395 watts MODULE LENGTH 67.79" MODULE WIDTH 44.64" MODULE THICKNESS 1.18" MODULE WEIGHT 47.39 lbs EXPANSION JOINTS Every 40' RAILS DIRECTION CROSS-SLOPE BUILDING HEIGHT 15.00 ft SHORTEST BUILDING LENGTH 20.00 ft ROOF TYPE Shingle ROOF SUBSTRATE Plywood ATTACHMENT TYPE Flashloc Duo * TOTAL WEIGHT 2027.96 lbs MID CLAMP Universal AF Clamp END CLAMP Universal AF Clamp * Calculated based on suggested quantity given on part list. Roof Area 1: Array 1 Portrait Modules - Rails Running Across Slope (for rails with attachments > 3) SOLARMOUNT LIGHT RAIL SPANS [IN] 1, 2E, 2R 2N, 3R 3E DESIGN SPAN (NON- EXPOSED) 22 22 22 DESIGN SPAN (EXPOSED) 22 22 17 Max Cantilever (Non- Exposed) 7 7 7 Max Cantilever (Exposed) 7 7 5 Max Span (Non- Exposed) 22 22 22 Max Span (Exposed) 22 22 17 ZONES 1, 2E, 2R 2N, 3R 3E NO OF RAILS(EXPOSED) 2 2 2 NO OF RAILS(NON- EXPOSED) 2 2 2 DESIGN PRESSURES [PSF] 1, 2E, 2R 2N, 3R 3E Up (Non-Exposed) -13.6 -15.3 -21.9 Up (Exposed) -21.2 -23.7 -34.9 Down (Non-Exposed) 27.5 27.5 27.5 Down (Exposed) 27.5 27.5 27.5 Downslope 15.1 15.1 15.1 Lateral 0.1 0.1 0.1 POINT LOADS FOR DESIGN SPAN MAXIMUM POINT LOADS [LBS] 1, 2E, 2R 2N, 3R 3E Up (Non-Exposed) -70.6 -79.3 -113.2 Up (Exposed) -109.7 -122.7 -139.8 Down (Non-Exposed) 142.3 142.3 142.3 Down (Exposed) 142.3 142.3 109.9 Downslope (Non-Exposed) 78.4 78.4 78.4 Downslope (Exposed) 78.4 78.4 60.6 Lateral (Non-Exposed) 0.4 0.4 0.4 Lateral (Exposed) 0.4 0.4 0.3 Tributary Area (Non-Exposed) [ft ] 5.2 5.2 5.2 Tributary Area (Exposed) [ft ] 5.2 5.2 4.0 ROOF PITCH:30° POINT LOADS FOR MAX SPAN MAXIMUM POINT LOADS [LBS] 1, 2E, 2R 2N, 3R 3E Up (Non-Exposed) -73.8 -82.9 -118.4 Up (Exposed) -114.6 -128.2 -145.2 Down (Non-Exposed) 148.7 148.7 148.7 Down (Exposed) 148.7 148.7 114.2 Downslope (Non-Exposed) 82.0 82.0 82.0 Downslope (Exposed) 82.0 82.0 62.9 Lateral (Non-Exposed) 0.4 0.4 0.4 Lateral (Exposed) 0.4 0.4 0.3 Tributary Area (Non-Exposed) [ft ] 5.4 5.4 5.4 Tributary Area (Exposed) [ft ] 5.4 5.4 4.2 ROOF PITCH:30° 2 2 2 2 Portrait Modules - Rails Running Across Slope (for rails with attachments <= 3) SOLARMOUNT LIGHT RAIL SPANS [IN] 1, 2E, 2R 2N, 3R 3E DESIGN SPAN (NON- EXPOSED) 21 21 21 DESIGN SPAN (EXPOSED) 21 21 15 Max Cantilever (Non- Exposed) 7 7 7 Max Cantilever (Exposed) 7 7 5 Max Span (Non- Exposed) 21 21 21 Max Span (Exposed) 21 21 15 ZONES 1, 2E, 2R 2N, 3R 3E NO OF RAILS(EXPOSED) 2 2 2 NO OF RAILS(NON- EXPOSED) 2 2 2 DESIGN PRESSURES [PSF] 1, 2E, 2R 2N, 3R 3E Up (Non-Exposed) -13.6 -15.3 -22.0 Up (Exposed) -21.2 -23.7 -35.6 Down (Non-Exposed) 27.5 27.5 27.5 Down (Exposed) 27.5 27.5 27.5 Downslope 15.1 15.1 15.1 Lateral 0.1 0.1 0.1 POINT LOADS FOR DESIGN SPAN MAXIMUM POINT LOADS [LBS] 1, 2E, 2R 2N, 3R 3E Up (Non-Exposed) -67.4 -75.7 -108.9 Up (Exposed) -104.7 -117.1 -125.8 Down (Non-Exposed) 135.8 135.8 135.8 Down (Exposed) 135.8 135.8 97.0 Downslope (Non-Exposed) 74.8 74.8 74.8 Downslope (Exposed) 74.8 74.8 53.5 Lateral (Non-Exposed) 0.4 0.4 0.4 Lateral (Exposed) 0.4 0.4 0.3 Tributary Area (Non-Exposed) [ft ] 4.9 4.9 4.9 Tributary Area (Exposed) [ft ] 4.9 4.9 3.5 ROOF PITCH:30° POINT LOADS FOR MAX SPAN MAXIMUM POINT LOADS [LBS] 1, 2E, 2R 2N, 3R 3E Up (Non-Exposed) -67.5 -75.8 -109.1 Up (Exposed) -104.8 -117.3 -132.8 Down (Non-Exposed) 136.0 136.0 136.0 Down (Exposed) 136.0 136.0 102.4 Downslope (Non-Exposed) 75.0 75.0 75.0 Downslope (Exposed) 75.0 75.0 56.4 Lateral (Non-Exposed) 0.4 0.4 0.4 Lateral (Exposed) 0.4 0.4 0.3 Tributary Area (Non-Exposed) [ft ] 4.9 4.9 4.9 Tributary Area (Exposed) [ft ] 4.9 4.9 3.7 ROOF PITCH:30° 2 2 2 2 Clamp Checks - Exposed zones ZONES 1, 2E, 2R 2N, 3R 3E CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A 435 435 N/A 489 N/A N/A N/A N/A Check OK OK OK OK OK OK OK OK OK Side Load N/A 318 318 N/A 318 N/A N/A N/A N/A Check OK OK OK OK OK OK OK OK OK Lateral Load N/A 2 2 N/A 2 N/A N/A N/A N/A Check OK OK OK OK OK OK OK OK OK Clamp Checks - Non-Exposed zones ZONES 1, 2E, 2R 2N, 3R 3E CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A 280 280 N/A 316 N/A N/A N/A N/A Check OK OK OK OK OK OK OK OK OK Side Load N/A 318 318 N/A 318 N/A N/A N/A N/A Check OK OK OK OK OK OK OK OK OK Lateral Load N/A 2 2 N/A 2 N/A N/A N/A N/A Check OK OK OK OK OK OK OK OK OK N/A stands for not applicable SOLARMOUNT Flush Product Assumptions Limitations of Responsibility: It is the user’s responsibility to ensure that inputs are correct for your specific project. Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or building design for this project. Allowable spans and resulting point loads are subject to the following conditions: 1. Building Height ≤ 60.00 ft unless otherwise specified. 2. Roof Slope ≥ 1.2° 3. Maximum rail cantilever ≤ 1/3 of selected span. 4. Occupancy/Risk Category I to IV. 5. Basic Wind Speed: 85.00 mph - 190.00 mph (IBC 2018/ASCE 7-16). Wind Exposure: B, C or D. 6. Ground Snow Load: 0.00 psf - 100.00 psf. (Reduction can be input if this is acceptable with your local building authority). Results are based on uniform snow loading and do not consider unbalanced, drifting, and sliding conditions. 7. Dead Load ≤ 5.00 psf (includes PV Modules and Racking). 8. Maximum PV Module Length: 120.00". 9. Seismic: Installations must be in seismic site class A, B, C, or D as defined in IBC 2006/ASCE 7-05. 10. Intermediary Span Distances: Roof attachment point loads be reduced linearly if the installed distance between the attachments is less than the selected span. For example, if the spacing is half the amount shown in the results, then the point loads may also be reduced by half. 11. Spans greater than 96.00".: While our products are valid for greater spans in many instances, we do not recommend this mounting configuration. Typical residential roofs are not designed for the larger point loads that might result from such excessive spans and we recommend final design by a licensed professional engineer of responsible charge. Pitched Roof Solutions (Flush Mounted Solutions): Modules are parallel to the roof surface and within 10.00". of it. Allowable roof pitch: 1.2°-45°. (SM is not fire tested for sloped of < 2:12, please check with your AHJ if this is acceptable.) Building has a monoslope roof with a slope ≤ 3°, a gable roof ≤ 45°, or a hip roof ≤ 27°. INSTALLATION AND DESIGN PLAN Roof Area 1 Rail type is shown along with quantity, including fractional lengths of each. For example, SM RAIL 168" MILL 2x(1/2) refers to using 2 rail segments that are 1/2 the length of the 168" rail(2x84" segments) ROW - SECTION NO MODULES RAIL TYPE, LENGTH, QTY SPLICES ROOF ATTACHMENTS 1-1 9 • SM LIGHT RAIL 246" MILL 2 + 2x(3/4) 2 40 2-1 9 • SM LIGHT RAIL 246" MILL 2 + 2x(3/4) 2 40 3-1 9 • SM LIGHT RAIL 246" MILL 2 + 2x(3/4) 2 40 4-1 9 • SM LIGHT RAIL 246" MILL 2 + 2x(3/4) 2 40 Field adjustments must be made in compliance with guidelines found in the Solarmount Installation Guide. Minimum of 2 attachments per rail segment; maximum cantilever length must be maintained on row ends adjacent to splices per module zone. ROOF AREA 1 / ROOF AREA 1 - ARRAY 1 LEGEND Module (Roof Zones) Exposed / / / / Non-Exposed 1, 2e, 2r 2n, 3r 3e