Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA215303-Randall building permit packet
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND Customer Approval of Array and Equipment layout:All Equipment is Outside 1 AC Combiner Panel 2 Fused Utility AC Disconnect 3 Production Meter Date:4 AC Disconnect - Protective Device 5 Utility Bi-Meter - Main Service Entrance NTS Champion Solar 7010 US Hwy 61 Minnesota City, MN 55959 507-312-0190 Customer Information Robert Randall 5226 175th St W The array covers more than 33% of the roof space thus there is a 36" walkway and 36" clearance from the horizontal peak. No clearance issue, 24hr keyless/unescorted access to disconnects and meters. The production meter and AC Disconnect should be located together in a readily accessible, visible, lockable, location within 10' of the main service meter. The array occupies less than 33% of total roof space and allows for 18" from edges and horizontal peak of dwelling. The 33% rule does not apply do to this not being a dwelling Farmington, MN 55024 Application # 7945 Date 6/1/2023 Description: DSGN - 4004 - Site Map Page: 1 of 1 1,2,3,4,5 N House # 5226 =44ft from 175 St W House # 5226 = 10 ft from Elkwood Ave Main Service Enterance 36" 36" 150ft Property N to S 80ft PropertyE to W Champion Solar DSGN - 4006 - PHOTO SUBMISSION DCN No. DNC-A00 Print Date: 3/8/2023 NTS Date 6/6/2023 Description: Details of photo Page: 1 of 1 Champion Solar 7010 US Hwy 61 Minnesota City, MN 55959 507-312-0190 Customer Information Robert Randall 5226 175th St W Farmington, MN 55024 Application # U-BUILDER PROJECT REPORT APPLICATION VERSION: 6.0.5PROJECT VERSION: 0.0.31 PROJECT TITLE NXT UMOUNT PROJECT ID 2F664C88 LAST UPDATED May. 30, 2023 ORIGINALLY CREATED May. 30, 2023 NAME ADDRESS 5226 175th St W, Farmington, MN 55024, USA CITY, STATE Farmington, MN MODULE JA Solar JAM54S31 395/MR Designed by apelowski@wresolar.com NXT UMOUNT JA Solar 36 - JAM54S31 395/MR 14.22 KW NOTE: Installation of the project is intended to happen within the year of project designed in UBuilder. If it's past one year please rerun the design or contact Unirac Engineering Services. ENGINEERING REPORT * Distributed Dead Load 2.65 psf * Average Roof Point Dead Load 13.20 lbs Plan Review TOTAL NUMBER OF MODULES 36 TOTAL KW 14.22 KW TOTAL AREA ~757 ft Loads Used for Design BUILDING CODE ASCE 7-10 BASIC WIND SPEED 109.00 mph GROUND SNOW LOAD 60.00 psf L-FOOT DIRECTION For ground snow loads >= 40.00 psf install the l-foot in upslope direction. See the high- snow attachment document above. SEISMIC, S 0.047 ELEVATION 919.00 ft WIND EXPOSURE B TOPOGRAPHICAL FACTOR K 1.00 2 S ZT Inspection PRODUCT NXT UMOUNT MODULE MANUFACTURER JA Solar MODEL 36 - JAM54S31 395/MR MODULE WATTS 395 watts MODULE LENGTH 67.79" MODULE WIDTH 44.64" MODULE THICKNESS 1.18" MODULE WEIGHT 47.30 lbs EXPANSION JOINTS Every 40' RAILS DIRECTION EW BUILDING HEIGHT 15.00 ft SHORTEST BUILDING LENGTH 20.00 ft ROOF TYPE Shingle ROOF SUBSTRATE Plywood ATTACHMENT TYPE Flashloc Duo RAFTER SPACING 1.00" * TOTAL WEIGHT 2006.80 lbs ROW SPACING 0.50" COLUMN SPACING 0.50" MID CLAMP NXT UMOUNT COMBO CLAMP END CLAMP NXT UMOUNT COMBO CLAMP * Calculated based on suggested quantity given on part list. Roof Area 1: Array 1 Portrait Modules - Rails Running Across Slope NXT UMOUNT RAIL SPANS [IN] ZONE 1 ZONE 2 ZONE 3 DESIGN SPAN 22 22 22 Max Cantilever 7 7 7 Max Span 22 22 22 ZONES ZONE 1 ZONE 2 ZONE 3 NO OF RAILS 2 2 2 DESIGN PRESSURES [PSF] ZONE 1 ZONE 2 ZONE 3 Up -9.9 -12.2 -12.2 Down 25.2 25.2 25.2 Downslope 13.1 13.1 13.1 Lateral 0.2 0.2 0.2 POINT LOADS FOR DESIGN SPAN MAXIMUM POINT LOADS [LBS] ZONE 1 ZONE 2 ZONE 3 Up -51.3 -63.2 -63.2 Down 130.5 130.5 130.5 Downslope 67.8 67.8 67.8 Lateral 1.0 1.0 1.0 Tributary Area [ft ] 5.2 5.2 5.2 ROOF PITCH:30° POINT LOADS FOR MAX SPAN MAXIMUM POINT LOADS [LBS] ZONE 1 ZONE 2 ZONE 3 Up -53.4 -65.8 -65.8 Down 136.0 136.0 136.0 Downslope 70.7 70.7 70.7 Lateral 1.1 1.1 1.1 Tributary Area [ft ] 5.4 5.4 5.4 ROOF PITCH:30° 2 2 Clamp Checks ZONES ZONE 1 ZONE 2 ZONE 3 CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A 208 208 N/A 256 256 N/A 256 N/A Check OK OK OK OK OK OK OK OK OK Side Load N/A 208 208 N/A 256 256 N/A 256 N/A Check OK OK OK OK OK OK OK OK OK Lateral Load N/A 208 208 N/A 256 256 N/A 256 N/A Check OK OK OK OK OK OK OK OK OK N/A stands for not applicable NXT UMOUNT U-BUILDER PRODUCT ASSUMPTIONS Limitations of Responsibility: It is the user’s responsibility to ensure that inputs are correct for your specific project. Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or building design for this project. Building Assumptions 1. Building Risk Category II. 2. Mean Roof Height = 0 – 60 ft unless otherwise specified. 3. Roof Pitch: 5° - 45° for ASCE 7-10 and 9° - 45° for ASCE 7-16 Wind Design Assumptions 1. Exposure Category B, C, or D 2. Basic Wind Speed 95 – 190 mph for ASCE 7-10, and 85-190 mph for ASCE 7-16. 3. Wind speeds are LRFD values 4.γE = 1.0 for ‘Interior’ spans, γE = 1.5 for ‘Exposed’ spans (ASCE 7-16 Sec. 29.4.3, Fig. 29.4-7) Snow and Seismic Design Assumptions 1. Ground Snow Load = 0-100 psf 2. Thermal Factor = 1.0 3. Results based on uniform snow load 4. 0.2-s Spectral Response Acceleration, SS ≤ 3 Array Assumptions 1. Dead Load≤ 5 psf (including PV Modules and Racking) 2. Module orientation and Rail direction per user selection 3. Module height above roof surface 5” to 10” depending on attachment type 4. Gaps between module rows and columns is 0.25”-1.0” 5. Modules are parallel to the roof surface and within 10 in. of it. 6. ‘Exposed’ spans shall be used when any part of an exposed module or panel as is attributed to that span. 7. The most restrictive of all roof zone spans shall be used when any part of the module is attributed to that span. Intermediary Span Distances: Roof attachment point loads be reduced linearly if the installed distance between the attachments is less than the selected span. For example, if the spacing is half the amount shown in the results, then the point loads may also be reduced by half. Spans greater than 72 in.: While our products are valid for greater spans in many instances, we do not recommend this mounting configuration. Typical residential roofs are not designed for the larger point loads that might result from such excessive spans and we recommend final design by a licensed professional engineer of responsible charge. DATA SHEET IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8M and IQ8A support split-phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. IQ8MA-12A-DS-0069-03-EN-US-2022-12-27 (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters INPUT DATA (DC)IQ8M-72-2-US IQ8A-72-2-US Commonly used module pairings1 W 260 – 460 295 – 500 Module compatibility 54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half-cell and 72-cell / 144 half-cell MPPT voltage range V 30 – 45 32 – 45 Operating range V 16 – 58 Min. / Max. start voltage V 22 / 58 Max. input DC voltage V 60 Max. continuous input DC current A 12 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8M-72-2-US IQ8A-72-2-US Peak output power VA 330 366 Max. continuous output power VA 325 349 Nominal (L-L) voltage / range2 V 240 / 211 – 264 Max. continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 47 – 68 AC short circuit fault current over 3 cycles Arms 2 Max. units per 20 A (L-L) branch circuit3 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.8 97.7 CEC weighted efficiency %97.5 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (H x W x D)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MA-12A-DS-0069-03-EN-US-2022-12-27