Loading...
HomeMy WebLinkAboutLA215396 - 17716 Ellsworth Drive - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.SEE COLUMN DETAIL SHEET A-5017" / 12"GARAGE PLATE HEIGHT10' - 9 3/8"4" / 12"7" / 12"8" 12"8" 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:12:55 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-201OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAHSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONS/ ROOFA-401 FOUNDATION PLANA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SCHEDULES/ DETAILSA-502 DETAILSConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode07/11/2023dmathews 24" RETURNSTYPICAL7" 12"8" / 12"8" / 12"7" 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"8" 12"24" RETURNSTYPICAL7" 12"4" 12"8" / 12"STANDARD ENERGY HEELS @ 7:12W/ 8:12 FASCIA LINES TO MATCH18" OVERHANGS & 12" RAKES TYP.8 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"7" / 12"STANDARD ENERGY HEELS @ 4:12 W/7:12 & 8:12 FASCIA LINES TO MATCH8" / 12"8" / 12"4" / 12"8" / 12"8" / 12"2' - 6"1' - 6"7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:12:58 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-202OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/8" = 1'-0"A-2021LEFT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023RIGHT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit. 43' - 0"14' - 10"6' - 10"36' - 2"6' - 10"1' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE43' - 0"11' - 9"28' - 3"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.20' - 6"22' - 6"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"21' - 4"16' - 9 1/4"3' - 11 3/4"3' - 11 3/4"11' - 5 1/4"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING26' - 3 1/4"8' - 5 1/2"5' - 3 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"50' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"19' - 8"4' - 6"7' - 3"7' - 11"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.6' - 8 3/4"13' - 9 1/4"5' - 10 3/4"8' - 11 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY48" x 48" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:12:59 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-401OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. UNEXCAVATEDFURNACESUMPW. H.F. D.FAMILY ROOMBEDROOM #5BATH20' - 6"22' - 6"14' - 10"6' - 10"36' - 2"6' - 10"CO DET.18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING1' - 0"5' - 10"15' - 5"20' - 9"11' - 8"3' - 9"3' - 9"17' - 0"UNEXCAVATEDR & SH. @ 65"9' - 6"3' - 8"6' - 9"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING6' - 6 1/4"4' - 0 3/4"10' - 9"0' - 4"MECHANICALAIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"21' - 4"43' - 0"43' - 0"6' - 9"11' - 3"12' - 6"9' - 6"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"138040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"22/6 x 6/8R.O. 2' -8" x 6' -11"2-9 1/2" LSL2-9 1/2" LSL3-11 7/8" LSL W/3 TRIMMERSCS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.0' - 4"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES50' - 0"10' - 0"40' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.CLOSETSMOKEDET.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"42/8 x 6/8R.O. 2' -10" x 6' -11"22/6 x 6/8R.O. 2' -8" x 6' -11"48" F.G. SHWRR & SH. @ 65"22/6 x 6/8R.O. 2' -8" x 6' -11"4' - 11"5' - 10"8' - 11"KNEE WALL W/14" SPINDLES20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"19' - 8"SET SILL 6" ABOVE TREATED PLATE 6' - 7"4' - 2"2' - 6"74030 NVPWG TEMP.R.O. 4' -0" x 3' -0"H.H. 11' -8"4' VANITY2-2x10 W/ 2 TRIMMERS 2-2x10 FLUSHFLOOR GIRDER 2x6.36' - 2" (BRACED WALL LINE SPACING)40' - 0" (BRACED WALL LINE SPACING)15.0' BRACED WALL REQ'D13'-6" OF WALL BRACING REQUIRED BRACE TO FOUNDATION OR UNTIL MINIMUM IS MET 13'-6" OF WALL BRACING REQUIRED BRACE TO FOUNDATION OR UNTIL MINIMUM IS MET 15.0' BRACED WALL REQ'D13.6' BRACED WALL REQ'D1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:13:00 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-402OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAHFAN 22' - 6"20' - 6"36' - 0"7' - 0"50' - 0"3/0 x 6/8 1/2VIEW W/ 12"D.S. SLSTEEL6KITCHENFOYEROFFICEGARAGEPORCH18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"6' - 10"SMOKEDET.2-11 7/8" LSL12" CANT. ABOVE4' - 5 1/2"8' - 4 1/2"6' - 6"SEE COLUMN DETAIL SHEET A-50118" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.3-2x10 W/2 TRIMMERS2-2x10TYP.0' - 4 1/2"20' - 6"2' - 0"2-2x1210' - 0"40' - 0"SNACK BAR19' - 4"4' - 0"1' - 4"CS-WSP4' - 0" B.W.P.CS-WSP8' - 0" B.W.P.CS-WSP8' - 0" B.W.P.SINK2-2x103-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x102-2x10CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP8' - 0" B.W.P.43' - 0"18' - 11 3/4"2' - 6"7' - 1 1/4"5' - 5"6' - 0"11' - 6"3' - 9"3' - 9"17' - 0"21' - 0"20' - 8"9" HEAT DUCT1' - 0"6' - 0"15' - 3"6' - 8 5/8"11' - 0 1/4"3' - 0 1/8"EQEQ63650 NVPWG/3620 NVFA TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"6653636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"ATTICACCESSCS-WSP8' - 0" B.W.P.PAINTED CABINETSFULL TILE BACKSPLASH1416' x 8' O.H. GARAGE DOOR8' x 8' O.H.GARAGEDOOR1243' - 0"CS-WSP4' - 0" B.W.P.GAS LINE FOR COOKTOP1' - 2"55" LINEAR ELEC. F.P.6' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MUD RM.FRAME BOTTOM OFWINDOW @ 44" A.F.F.3-2x6PFH1' - 9"PFH2' - 1"PFH2' - 1"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESDWSET FIREPLACE 12" A.F.F.W/ MANTEL AND TILESURROUND 4' - 11"5' - 10"0' - 10"7' - 9"12/4 x 6/8R.O. 2' -6" x 6' -11"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISER-38 MIN. INSULATIONIN FLOOR ABOVE12/4 x 6/8R.O. 2' -6" x 6' -11"84/0 x 6/8R.O. 4' -2" x 6' -11"R & SH.73/0 x 6/8 OPG.105/0 x 6/8 OPG.2' - 0"2' - 0"KNEE WALL W/14" SPINDLES@ 6'-10" H.HABOVE LANDING PED. SINKDINING ROOM1312" TRANSOM / 6/0 x 6/8 SLIDERR.O. 6' -0" x 7' -8"POWDER126050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.6' - 0"EQEQEQEQGREAT ROOM6' - 7"5' - 0"28' - 5"CO DET.16" SH.PANTRY6' - 0"4' - 2"3' - 9 1/4"3' - 0"3' - 2"36" REF2x652/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"5' - 8"15' - 0"12' - 2"7' - 2"OPTIONAL BENCH84050 NVPWG TEMP.R.O. 4' -0" x 5' -0"H.H. 12' -5 11/16"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"U.C.LIGHTS U.C. LIGHTS U.C.LIGHTS 36" GAS COOKTOP W/ WOOD HOOD U.C. LIGHTS 2-2x102-2x10OR FLOOR GIRDER 2-2x102-9 1/2" LSL FLOOR GIRDER 2-2x10 FLUSH2-2x10GIRDER TRUSS WALL ABOVE BEARING ON FLOOR TRUSSES 3-2x615' - 0"4-2x65x5 PSL10' - 0" (BRACED WALL LINE SPACING)40' - 0" (BRACED WALL LINE SPACING)39' - 0" (BRACED WALL LINE SPACING)50' - 0" (BRACED WALL LINE SPACING)20' - 6" (BRACED WALL LINE SPACING)18' - 6" (BRACED WALL LINE SPACING)12.7' BRACED WALL REQ'D13.5' BRACED WALL REQ'D13.5' BRACED WALL REQ'D10.2' BRACED WALL REQ'D10.2' BRACED WALL REQ'D13.5' BRACED WALL REQ'D12.7' BRACED WALL REQ'D10.2' BRACED WALL REQ'D7.9' BRACED WALL REQ'D10.2' BRACED WALL REQ'DCS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.OVEN/MICRO1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:13:00 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-403OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAHBWPsAboveFANVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing. BEDROOM #4LAUNDRYBEDROOM #3HALLSMOKEDET.SMOKEDET.5' VANITYCLOSETSMOKEDET.GIRDER TRUSSCO DET.SMOKEDET.MFG. ROOF TRUSSESPER MFG. SPACINGATTICACCESS32/6 x 6/8 PKTR.O. 5' -2" x 6' -11"13' - 0"6' - 4"5' - 2"15' - 6"1' - 0"9' - 0"27' - 0"37' - 0"40' - 0"R & SH. @ 65"6' - 4"14' - 6"12' - 5"6' - 9"CLOSETBATH2x65' VANITY6' - 6"6' - 6"3' - 2"3' - 2"2' - 6"2' - 8"2-2x10 W/2 TRIMMERS2-2x102-2x10CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.40' - 0"9' - 2"2' - 2 1/4"7' - 0 3/4"6' - 2 1/4"3' - 8"7' - 8 3/4"3' - 8"3' - 11"5' - 5"13' - 6"11' - 6"3' - 8"3' - 8"6' - 0 1/4"2' - 0"3' - 3 1/2"9' - 10 1/4"2-9 1/2" LSL 2-2x10 W/2 TRIMMERS22020 NVFA2R.O. 4' -0" x 2' -0"H.H. 6' -10"105050E NVG1R.O. 5' -0" x 5' -0"H.H. 6' -10"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"SMOKEDET.3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE42/8 x 6/8R.O. 2' -10" x 6' -11"3-2x63-2x695/0 x 6/8R.O. 5' -2" x 6' -11"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHALF WALL W/ WOOD CAP 22/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"14' - 4"5' - 0"22/6 x 6/8R.O. 2' -8" x 6' -11"5' TUB/SHWR116020 NVFA3R.O. 6' -0" x 2' -0"H.H. 6' -10"16' - 3"20' - 9"4' - 0"2' - 6"11' - 1"84/0 x 6/8R.O. 4' -2" x 6' -11"R & SH. @ 65"12/4 x 6/8R.O. 2' -6" x 6' -11"LINEN22/6 x 6/8R.O. 2' -8" x 6' -11"22/6 x 6/8R.O. 2' -8" x 6' -11"4' - 11"5' - 10"29' - 3"17' - 0"3' - 9"3' - 9"12' - 6"3' - 8"22/6 x 6/8R.O. 2' -8" x 6' -11"R & SH. @ 65"BEDROOM #27' - 3"6' - 10 1/4"7' - 2"1' - 4"6' - 7 3/4"R & SH. @ 65"MFG. ROOF TRUSSESPER MFG. SPACING37' - 0"148050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"1' - 0"10' - 0"MFG. ROOF TRUSSESPER MFG. SPACING22/6 x 6/8R.O. 2' -8" x 6' -11"60" F.G. SHWRW/ TILE WALLS& BY-PASSDOOR33016 NVA1R.O. 3' -0" x 1' -6"H.H. 6' -10"17' - 2 1/4"9' - 9 3/4"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"OWNER'S SUITESINKWASHERDRYER2-2x102-2x1020' - 0" (BRACED WALL LINE SPACING)20' - 0" (BRACED WALL LINE SPACING)11' - 0" (BRACED WALL LINE SPACING)26' - 0" (BRACED WALL LINE SPACING)40' - 0" (BRACED WALL LINE SPACING)37' - 0" (BRACED WALL LINE SPACING)5.5' BRACED WALL REQ'D4.0' BRACED WALL REQ'D5.5' BRACED WALL REQ'D5.0' BRACED WALL REQ'D4.6' BRACED WALL REQ'D5.0' BRACED WALL REQ'D5.5' BRACED WALL REQ'D5.5' BRACED WALL REQ'D5.0' BRACED WALL REQ'D5.0' BRACED WALL REQ'DCS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:13:02 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-404OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/4" = 1'-0"A-4041UPPER FLOOR PLANTemper ifwithin 60"of tub floor.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FANFAN WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:13:03 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-501OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 1 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2020 NVFA2 4' - 0" 2' - 0" 6' - 10"3 VECTOR ENVISION SERIES 1 3016 NVA1 3' - 0" 1' - 6" 6' - 10"4 VECTOR ENVISION SERIES 2 3016 NVPWG 3' - 0" 1' - 6" 8' - 0"5 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 7' - 2"6 VECTOR ENVISION SERIES 3 3650 NVPWG/3620 NVFA TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"7 VECTOR ENVISION SERIES 1 4030 NVPWG TEMP. 4' - 0" 3' - 0" 11' - 8"8 VECTOR ENVISION SERIES 1 4050 NVPWG TEMP. 4' - 0" 5' - 0" 12' - 5 11/16"9 VECTOR ENVISION SERIES 3 5040E NVG1 5' - 0" 4' - 0" 6' - 10"10 VECTOR ENVISION SERIES 1 5050E NVG1 5' - 0" 5' - 0" 6' - 10"11 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 6' - 10"12 VECTOR ENVISION SERIES 1 6050E NVG1 6' - 0" 5' - 0" 6' - 10"13 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"14 VECTOR ENVISION SERIES 1 8050E NVGE 8' - 0" 5' - 0" 6' - 10"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 449 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 155 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 43 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 70 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 223 SF 8' - 2" FINISH PER CODELOWER FLOOR BATH VINYL 47 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 119 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 77 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD RM. VINYL 53 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 29 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 175 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 145 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 245 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 145 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 30 SF 9' - 1 1/8"UPPER FLOOR BEDROOM #4 CARPET 159 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 155 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 176 SF 8' - 1 1/8"UPPER FLOOR HALL CARPET 119 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 66 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 37 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 134 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY VINYL 51 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE VINYL 92 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 54 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 42 2/6 x 6/8 2' - 8" 6' - 11" 93 2/6 x 6/8 PKT 5' - 2" 6' - 11" 14 2/8 x 6/8 2' - 10" 6' - 11" 25 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 16 3/0 x 6/8 1/2 VIEW W/ 12" D.S. SL STEEL 17 3/0 x 6/8 OPG. 18 4/0 x 6/8 4' - 2" 6' - 11" 29 5/0 x 6/8 5' - 2" 6' - 11" 110 5/0 x 6/8 OPG. 111 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 112 8' x 8' O.H. GARAGE DOOR 113 12" TRANSOM / 6/0 x 6/8 SLIDER 6' - 0" 7' - 8" 114 16' x 8' O.H. GARAGE DOOR 1 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/26/2023 11:13:04 AMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-502OTT3716.9.23 CB126211307776.13.23 CB6.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION1/2" = 1'-0"A-5027GARAGE CEILING MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.SEE COLUMN DETAIL SHEET A-5017" / 12"GARAGE PLATE HEIGHT10' - 9 3/8"4" / 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:24 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-201OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAHSHEET INDEXSHEET NAME SHEET NUMBERELEVATION A-201ELEVATIONS/ ROOF A-202FOUNDATION PLAN A-401LOWER FLOOR A-402MAIN FLOOR A-403UPPER FLOOR A-404SCHEDULES/ DETAILS A-501DETAILS A-502 24" RETURNSTYPICAL7" 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"24" RETURNSTYPICAL7" 12"4" 12"8" / 12"STANDARD ENERGY HEELS @ 7:12W/ 8:12 FASCIA LINES TO MATCH18" OVERHANGS & 12" RAKES TYP.8 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"7" / 12"STANDARD ENERGY HEELS @ 4:12 W/7:12 & 8:12 FASCIA LINES TO MATCH8" / 12"8" / 12"4" / 12"8" / 12"8" / 12"2' - 6"1' - 6"7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:25 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-202OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/8" = 1'-0"A-2021LEFT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023RIGHT ELEVATION1/8" = 1'-0"A-2024ROOF PLAN 43' - 0"14' - 10"6' - 10"36' - 2"6' - 10"1' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE43' - 0"11' - 9"28' - 3"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.20' - 6"22' - 6"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"21' - 4"16' - 9 1/4"3' - 11 3/4"3' - 11 3/4"11' - 5 1/4"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING26' - 3 1/4"8' - 5 1/2"5' - 3 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"50' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.20' - 2"11' - 0"19' - 1"31' - 2"50' - 3"19' - 8"4' - 6"7' - 3"7' - 11"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:26 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-401OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/4" = 1'-0"A-4011FOUNDATION PLAN UNEXCAVATEDFURNACESUMPW. H.F. D.FAMILY ROOMBEDROOM #5BATH20' - 6"22' - 6"14' - 10"6' - 10"36' - 2"6' - 10"CO DET.18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING1' - 0"5' - 10"15' - 5"20' - 9"11' - 8"3' - 9"3' - 9"17' - 0"UNEXCAVATEDR & SH. @ 65"9' - 6"3' - 8"6' - 9"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING6' - 6 1/4"4' - 0 3/4"10' - 9"0' - 4"MECHANICALAIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"21' - 4"43' - 0"43' - 0"6' - 9"11' - 3"12' - 6"9' - 6"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"138040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"22/6 x 6/8R.O. 2' -8" x 6' -11"2-9 1/2" LSL2-9 1/2" LSL3-9 1/2" LVL W/3 TRIMMERSCS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.0' - 4"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES50' - 0"10' - 0"40' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.CLOSETSMOKEDET.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"42/8 x 6/8R.O. 2' -10" x 6' -11"22/6 x 6/8R.O. 2' -8" x 6' -11"48" F.G. SHWRR & SH. @ 65"22/6 x 6/8R.O. 2' -8" x 6' -11"4' - 11"5' - 10"8' - 11"KNEE WALL W/14" SPINDLES20' - 2"11' - 0"19' - 1"31' - 2"50' - 3"19' - 8"SET SILL 6" ABOVE TREATED PLATE 6' - 7"4' - 2"2' - 6"74030 NVPWG TEMP.R.O. 4' -0" x 3' -0"H.H. 11' -8"4' VANITY1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:27 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-402OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***||[]]][]][][||||[]][||[][][||][][]]][ = Loaded for Future Deck LoadOKOK2-2x103 - 11-7/8" LSL2-2x102 - Trimmers 22' - 6"20' - 6"36' - 0"7' - 0"50' - 0"3/0 x 6/8 1/2VIEW W/ 12"D.S. SLSTEEL6KITCHENFOYEROFFICE30" RANGEGARAGEPORCH18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL12" CANT. ABOVE4' - 5 1/2"8' - 4 1/2"6' - 6"SEE COLUMN DETAIL SHEET A-50118" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.3-2x10 W/2 TRIMMERS2-2x10TYP.0' - 4 1/2"20' - 6"2' - 0"2-2x1210' - 0"40' - 0"SNACK BAR19' - 4"4' - 0"1' - 4"CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.SINK2-2x102-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x102-2x10CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP5' - 0" B.W.P.43' - 0"18' - 11 3/4"2' - 6"7' - 1 1/4"5' - 5"6' - 0"11' - 6"3' - 9"3' - 9"17' - 0"21' - 0"20' - 8"9" HEAT DUCT1' - 0"6' - 0"15' - 3"6' - 8 5/8"11' - 0 1/4"3' - 0 1/8"EQEQ63650 NVPWG/3620 NVFA TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"6653636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"ATTICACCESSCS-WSP4' - 0" B.W.P.PAINTED CABINETSFULL TILE BACKSPLASH1416' x 8' O.H. GARAGE DOOR8' x 8' O.H.GARAGEDOOR1243' - 0"CS-WSP5' - 0" B.W.P.GAS LINE FOR RANGE1' - 2"55" LINEAR ELEC. F.P.6' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MUD RM.FRAME BOTTOM OFWINDOW @ 44" A.F.F.3-2x6PFH1' - 9"PFH2' - 1"PFH2' - 1"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESDWSET FIREPLACE 12" A.F.F.W/ MANTEL AND TILESURROUND 4' - 11"5' - 10"0' - 10"7' - 9"12/4 x 6/8R.O. 2' -6" x 6' -11"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISER-38 MIN. INSULATIONIN FLOOR ABOVE12/4 x 6/8R.O. 2' -6" x 6' -11"84/0 x 6/8R.O. 4' -2" x 6' -11"R & SH.73/0 x 6/8 OPG.105/0 x 6/8 OPG.2' - 0"2' - 0"KNEE WALL W/14" SPINDLES@ 6'-10" H.HABOVE LANDING PED. SINKDINING ROOM1312" TRANSOM / 6/0 x 6/8 SLIDERR.O. 6' -0" x 7' -8"POWDER126050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.6' - 0"EQEQEQEQGREAT ROOM6' - 7"5' - 0"CO DET.16" SH.PANTRY6' - 0"4' - 2"3' - 9 1/4"3' - 0"3' - 2"36" REF2x652/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"5' - 8"15' - 0"12' - 2"7' - 2"OPTIONAL BENCHBRACED WALL DESIGN WILL BE UPDATED WHEN PLAN IS FINISHED 84050 NVPWG TEMP.R.O. 4' -0" x 5' -0"H.H. 12' -5 11/16"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:28 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-403OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH[][][][]][][||||[]][OKOK2-2x103-2x10 Cont.OKOK2 - 9-1/2" LSL2-2x10OK2-2x10OKOKOK2-2x10OR Floor Girder2-2x10||[][][||][][]]][*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***4 - 2x65x5 PSL BEDROOM #4LAUNDRYBEDROOM #3HALLSMOKEDET.SMOKEDET.5' VANITYCLOSETSMOKEDET.GIRDER TRUSSCO DET.SMOKEDET.MFG. ROOF TRUSSESPER MFG. SPACINGATTICACCESS32/6 x 6/8 PKTR.O. 5' -2" x 6' -11"13' - 0"6' - 4"5' - 2"15' - 6"1' - 0"9' - 0"27' - 0"37' - 0"40' - 0"R & SH. @ 65"6' - 4"14' - 6"12' - 5"6' - 9"CLOSETBATH2x65' VANITY6' - 6"6' - 6"3' - 2"3' - 2"2' - 6"2' - 8"2-2x10 W/2 TRIMMERS2-2x102-2x10CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.40' - 0"9' - 2"2' - 2 1/4"7' - 0 3/4"6' - 2 1/4"3' - 8"7' - 8 3/4"3' - 8"3' - 11"5' - 5"13' - 6"11' - 6"3' - 8"3' - 8"6' - 0 1/4"2' - 0"3' - 3 1/2"9' - 10 1/4"2-2x102-2x10 W/2 TRIMMERS22020 NVFA2R.O. 4' -0" x 2' -0"H.H. 6' -10"105050E NVG1R.O. 5' -0" x 5' -0"H.H. 6' -10"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"SMOKEDET.3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE42/8 x 6/8R.O. 2' -10" x 6' -11"3-2x63-2x695/0 x 6/8R.O. 5' -2" x 6' -11"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHALF WALL W/ WOOD CAP 22/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"14' - 4"5' - 0"22/6 x 6/8R.O. 2' -8" x 6' -11"5' TUB/SHWR116020 NVFA3R.O. 6' -0" x 2' -0"H.H. 6' -10"16' - 3"20' - 9"4' - 0"2' - 6"11' - 1"84/0 x 6/8R.O. 4' -2" x 6' -11"R & SH. @ 65"12/4 x 6/8R.O. 2' -6" x 6' -11"LINEN22/6 x 6/8R.O. 2' -8" x 6' -11"22/6 x 6/8R.O. 2' -8" x 6' -11"4' - 11"5' - 10"29' - 3"17' - 0"3' - 9"3' - 9"12' - 6"3' - 8"22/6 x 6/8R.O. 2' -8" x 6' -11"R & SH. @ 65"BEDROOM #27' - 3"6' - 10 1/4"7' - 2"1' - 4"6' - 7 3/4"R & SH. @ 65"MFG. ROOF TRUSSESPER MFG. SPACING37' - 0"148050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"1' - 0"10' - 0"MFG. ROOF TRUSSESPER MFG. SPACING22/6 x 6/8R.O. 2' -8" x 6' -11"60" F.G. SHWRW/ BY-PASSDOOR33016 NVA1R.O. 3' -0" x 1' -6"H.H. 6' -10"17' - 2 1/4"9' - 9 3/4"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"OWNER'S SUITESINKWASHERDRYERTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:30 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-404OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/4" = 1'-0"A-4041UPPER FLOOR PLAN2 - 9-1/2" LSLOKOK2-2x102-2x10OKOKOKOK2-2x10||[][][][]][][||||[]][*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise *** WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:31 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-501OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 1 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2020 NVFA2 4' - 0" 2' - 0" 6' - 10"3 VECTOR ENVISION SERIES 1 3016 NVA1 3' - 0" 1' - 6" 6' - 10"4 VECTOR ENVISION SERIES 2 3016 NVPWG 3' - 0" 1' - 6" 8' - 0"5 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 7' - 2"6 VECTOR ENVISION SERIES 3 3650 NVPWG/3620 NVFA TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"7 VECTOR ENVISION SERIES 1 4030 NVPWG TEMP. 4' - 0" 3' - 0" 11' - 8"8 VECTOR ENVISION SERIES 1 4050 NVPWG TEMP. 4' - 0" 5' - 0" 12' - 5 11/16"9 VECTOR ENVISION SERIES 3 5040E NVG1 5' - 0" 4' - 0" 6' - 10"10 VECTOR ENVISION SERIES 1 5050E NVG1 5' - 0" 5' - 0" 6' - 10"11 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 6' - 10"12 VECTOR ENVISION SERIES 1 6050E NVG1 6' - 0" 5' - 0" 6' - 10"13 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"14 VECTOR ENVISION SERIES 1 8050E NVGE 8' - 0" 5' - 0" 6' - 10"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 449 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 155 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 43 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 70 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 223 SF 8' - 2" FINISH PER CODELOWER FLOOR BATH VINYL 47 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 119 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 77 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD RM. VINYL 53 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 29 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 175 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 145 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 245 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 145 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 30 SF 9' - 1 1/8"UPPER FLOOR BEDROOM #4 CARPET 159 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 155 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 176 SF 8' - 1 1/8"UPPER FLOOR HALL CARPET 119 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 66 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 37 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 134 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY VINYL 51 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE VINYL 92 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 54 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 42 2/6 x 6/8 2' - 8" 6' - 11" 93 2/6 x 6/8 PKT 5' - 2" 6' - 11" 14 2/8 x 6/8 2' - 10" 6' - 11" 25 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 16 3/0 x 6/8 1/2 VIEW W/ 12" D.S. SL STEEL 17 3/0 x 6/8 OPG. 18 4/0 x 6/8 4' - 2" 6' - 11" 29 5/0 x 6/8 5' - 2" 6' - 11" 110 5/0 x 6/8 OPG. 111 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 112 8' x 8' O.H. GARAGE DOOR 113 12" TRANSOM / 6/0 x 6/8 SLIDER 6' - 0" 7' - 8" 114 16' x 8' O.H. GARAGE DOOR 1 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:6/6/2023 3:35:32 PMSARAH MODELL36, B1- PHEASANT RUN 7TH ADD'N17716 ELLSWORTH DRIVELAKEVILLE, MN 55044A-502OTT371126211307776.6.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3169SARAH1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION 18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLANDY @ 651-688-3613OREMAIL: AHOERNEMANN@VILLAUME.COMF1F12F2F3F3F4F4F6F7F7F7F8F8F8F9F9F9F10F10F10F10F11F13F13F13F13F13F15F5F14F14F14F1417-00-003-09-003-09-0011-06-0040-00-0036-00-0019-04-0020-08-0021-00-0015-00-008-00-008-00-008-00-008-00-008-00-00Customer: Lyman Lumber - ChanhassenJob Number: 324413-AHome Owner: TOPAZ / SARAH MODELJob Name: RoofSite Address: 17716 ELLSWORTH DRIVE Sales Rep: Tony StimmlerCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/14/2023Version: 8.5.3.233 HANGER18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.EXTRA TRUSSES ADDED FOR PLUMBING.SHIFT TRUSSES TO AVOID PLUMBING.DO NOT OVER SPACE TRUSSES.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLANDY @ 651-688-3613OREMAIL: AHOERNEMANN@VILLAUME.COMLOFF1FF2FF2FF2FF3FF3FF5FF5FF5FF5FF6FF6FF6FF6FF6FF6FF6FF6FF6FF6FF7FF8FF9FF9FF9FF9FF9FF10FF12FF12FF12FF4FF2FF15FF15FF15FF15FF15FF15FF15FF14FF14FF14FF11FF13FF15E2E1E1E1E1E1E1EEEHGH7H6H5H4H3H2H1K1KKKV5BV6BV7B11-06-00 3-09-00 3-09-00 17-00-0036-00-001-00-008-00-008-00-008-00-008-00-008-00-0040-00-0010-00-004-02-001-10-0020-06-0020-06-002-00-0011-00-0020-02-00 5-10-00 13-00-00Customer: Lyman Lumber - ChanhassenJob Number: 324413-AHome Owner: TOPAZ / SARAH MODELJob Name: RoofSite Address: 17716 ELLSWORTH DRIVE Sales Rep: Tony StimmlerCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/14/2023Version: 8.5.3.233 HANGERLOE2E1E1E1E1E1E1EEEHGH7H6H5H4H3H2H1K1KKKV5BV6BV7B36-00-001-00-0040-00-0010-00-004-02-001-10-0020-06-0020-06-002-00-0011-00-0020-02-00 5-10-00 13-00-00A4A3A5A5A5A3A3A3A2A2A2AAAAAAAAAA1C1DC2CCCCV1V2V3V4Customer: Lyman Lumber - ChanhassenJob Number: 324413-AHome Owner: TOPAZ / SARAH MODELJob Name: RoofSite Address: 17716 ELLSWORTH DRIVE Sales Rep: Tony StimmlerCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/14/2023Version: 8.5.3.233 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93 Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's X " round duct OR 6" flex " metal duct ML19307016C Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 2.550 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 162 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 27266Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACX030 Model Heating System Natural Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.21 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.28 Appliances Mechanical room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 63152 Heating Gain Cooling Load 81 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.6/22/2023 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville 17716 Ellsworth Drive BC730925 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 2.5 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) 7/6/23 X PM