Loading...
HomeMy WebLinkAbout18116 Gavel LaRECEIVED By Hunter Dunne at 11:09 am, Jul 28, 2023 CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: ILA203252, LA203253, LA203254. LA203256 Legal Description: Lot17-2oBlock 2 Subdivision: GLACIER CREEK 3RD ADDITION Address: 1 81 04 18108 1 811 2 18116 Gavel Lane We hereby certify that on _ 14th day of July . 2023 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: /P to _ / Hawkinson Signature: Date: July 27, 2023 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 Encls. 1 0 N 4 h X goo ✓`n rn a a x 0 a Lot 17 and 20 Lot area = 6216 SF House area = 2652 SF Stoop area = 92 SF Sidewalk area =86 SF Driveway area = 364 SF 0 r_ N N N a, n • O, O, 4 a, CR X o+ GAVEL SANE " 141 o°°14O X r a, Lot 18 and 19 Lot area = 4736 SF House area = 2666 SF Stoop area = 92 SF Sidewalk area = 86 SF Driveway area = 364 SF en 0 WETLAND X N Deck area = 200 SF Deck area = 200 SF Total Impervious Area = 3394 SF Total Impervious Area = 3408 SF Impervious Coverage = 54.6% Impervious Coverage =72.0% nc nh in Nntac• I . ns a roc construction entrance 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1 0% 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. Wall will not be installed if the grade is 3 1 or less. General Notes: 1. Grading plan by Pioneer Enngineering last dated 12-03-2021 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4 No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. • 0 ■ 000.00 000 00 ) 3°0°, 40" W a, PItNEERneenng, P.A, CIVn. ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCnrftCTS X X rn x 0 Denotes iron pipe Denotes service Denotes television box Denotes electric box Denotes telephone box Denotes existing elevation Denotes proposed elevation Denotes drainage flow direction Denotes spike Denotes proposed retaining wall designed and built by others. TO X 0 X NO3 r x N rn TA X g6$ 9 CNw� I \ o x \ N \ X 0, X O, O \ X d-•— i X 0, ,D X a,0 en - x CD al X a, x m Xo, To OI X X a, 4 X •`n a' c1 X 0 - X 0' o+ x x 4 m °' 03 0 M o+ Lowest opening elevation per grading plan 971.0 Lowest floor elevation per grading plan : 971.2 House elevations (Proposed) / As —built Lowest Floor Elevation Top 0f Foundation Elev. Garage Slab Elev : (971.2) / 971.4 : (974.4) / 974.5 ® Door : (974.0) / 974.1 REVISED 7/14/23 GRADING AS —BUILT We hereby certify to Brandt Anderson Homes Inc that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 05/19/22. Signed: //Pioleer Engineering, P A BY: ressltirial Land Surveyor Minnesota License No. 42299 email—phawkinson@pioneereng.com Lot 17, 18, 19, 20, Block 2, GLACIER CREEK 3RD ADDITION according to the recorded plat thereof 2422 Enterprise Dnve Ph. : (651) 681-1914 Dakota County, Minnesota Mendota Heights, MN 55120 Fax: (651) 681-9488 www.ploneerengcom Address: 18104 18108 18112 18116 Gavel Lane, Lakeville, Minnesota House Model: Sable/Trillium Elevation: N/A Buyer: Brandl Anderson Homes S m f 4 CI, N 9 1 0` X 0 o+ 0' 10' 20' 111 Scale: 1" = 20' Benchmark: Top Nut Hydrant L20-21 B2 Elevation = 973.67 Revisions 1 ) 05-23-22 Stake house 2 ) 07-28-22 Restake house 3 ) 07-14-23 Grading As -bull) Certificate of Survey for: Brandl Anderson Homes Inc Project # .121205010 (Folder #:8625IDrawn by P.H $ © Pioneer Engineering 221 River Ridge Circle South, Suite 100 Burnsville, MN 55337 Phone- (952)898-0230