Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA216231-APPROVED - Nathan Clausen Permit Pack
1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 COVER SHEET PV1 GENERAL NOTES CODE AND STANDARDS 1. ALL WORK SHALL COMPLY WITH 2023 NATIONAL ELECTRIC CODE (NEC), 2018 INTERNATIONAL BUILDING CODE (IBC), 2020 INTERNATIONAL RESIDENTIAL CODE (IRC), 2020 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES . 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. SITE NOTES / OSHA REGULATION 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. SOLAR CONTRACTOR 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION REQUIREMENTS. 3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM. 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, DC COMBINERS, DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER NEC 690.4(B). 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. EQUIPMENT LOCATIONS 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A) AND NEC TABLE 310.15(B). 3. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 4. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. AERIAL VIEW DESIGN CRITERIA WIND SPEED: 115 mph GROUND SNOW LOAD: 50 lb/ft² WIND EXPOSURE FACTOR: C SEISMIC DESIGN CATEGORY: B SITE SPECIFICATIONS CONSTRUCTION - V-B ZONING: RESIDENTIAL SHEET INDEX PV1 - COVER SHEET PV2 - SITE PLAN PV3 - ROOF PLAN PV4 - STRUCTURAL PV5 - ELECTRICAL 3-LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS PV7 - WARNING LABELS AND LOCATIONS PV8 - PLACARD (ALL OTHER SHEETS AS REQUIRED) SS - PRODUCT SPEC. SHEETS UTILITY COMPANY: Dakota Electric Association PERMIT ISSUER: City of Lakeville PROJECT INFORMATION: NUMBER OF STORIES: 2 CONDUIT RUN: Interior ECOBEE QTY: 1 LIGHT BULB QTY: 0 PV METER: Utility PV Meter Required ROOF TYPE (1) INFORMATION: ROOF TYPE: Comp Shingle FRAMING TYPE: Manufactured Truss SHEATHING TYPE: OSB ATTACHMENT: SFM Infinity Flashkit RACKING: Unirac SFM Infinity @ 24" OC Portrait / 48" OC Landscape NUMBER OF ATTACHMENTS: 82 ROOF TYPE (2) INFORMATION (IF APPLICABLE): *SEE PV4.2 SCOPE OF WORK INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SYSTEM TO BE INSTALLED INFORMATION: DC SYSTEM SIZE: 9.24 kW DC AC SYSTEM SIZE: 6.908 kW AC MODULE TYPE: (22) REC Solar REC420AA PURE-R INVERTER TYPE: Enphase IQ7X-96-2-US MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 DCAC DCAC DCAC DCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACM MSPDCACDCACDCAC PVACCB 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 SITE PLAN PV2 SCALE: 1/16" = 1'-0" M MSP AC CB LC SUB PV TS MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER BOX LOAD CENTER SUBPANEL PV METER TRANSFER SWITCH JUNCTION BOX LEGEND FIRE SETBACK TRENCHING PROPERTY LINE ESS HUB RPO SUNPOWER ESS SUNPOWER HUB+ REMOTE POWER OFF PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES: 22 MODULE MAKE AND MODEL: REC Solar REC420AA PURE-R MODULE WATTAGE: 420W DC INVERTER MAKE AND MODEL: Enphase IQ7X-96-2-US INVERTER TYPE: Microinverter (1 Inverter per PV Module) INVERTER CURRENT OUTPUT: 1.31A AC INVERTER NOMINAL VOLTAGE: 240V INVERTER WATTAGE: 314W AC FRONT OF HOME19151 HUXLEY AVE DC AC DC AC DC AC DCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACM MSPDCACDCACDCAC PVACCB 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ROOF PLAN PV3 SCALE: 1/8" = 1'-0" M MSP AC CB LC SUB PV TS MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER BOX LOAD CENTER SUBPANEL PV METER TRANSFER SWITCH JUNCTION BOX LEGEND FIRE SETBACK TRENCHING PROPERTY LINE ESS HUB RPO SUNPOWER ESS SUNPOWER HUB+ REMOTE POWER OFF PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES: 22 MODULE MAKE AND MODEL: REC Solar REC420AA PURE-R MODULE WATTAGE: 420W DC INVERTER MAKE AND MODEL: Enphase IQ7X-96-2-US INVERTER TYPE: Microinverter (1 Inverter per PV Module) INVERTER CURRENT OUTPUT: 1.31A AC INVERTER NOMINAL VOLTAGE: 240V INVERTER WATTAGE: 314W AC FRONT OF HOMEMP1 # OF MODULES: 3 AZIMUTH: 112 PITCH: 27 TSRF: 75% AREA: 241 ft.² MP3 # OF MODULES: 13 AZIMUTH: 112 PITCH: 27 TSRF: 86% AREA: 575 ft.² UNDERGROUND SERVICE LINE POINT OF INTERCONNECTION MP4 # OF MODULES: 3 AZIMUTH: 112 PITCH: 27 TSRF: 83% AREA: 180 ft.² 3' 1'-6"1'-6" 1'-6"3' 3' 3' 1'-6"1'-6" 3' 3' 1'-6" 1'-6" 3' MP2 # OF MODULES: 3 AZIMUTH: 202 PITCH: 40 TSRF: 88% AREA: 238 ft.² 3' 1'-6" ATTACHMENT SPACING- SIDE VIEWDSCALE: 1/2" = 1'-0" B A LANDSCAPE PORTRAIT A B MODULE WIDTH MODULE WIDTH PV MODULE ROOF STRUCTURE 27° PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE PV MODULE UNIRAC SFM 2" MICRORAIL 16" MAX.48" MAX. 8" MAX.24" MAX. ATTACHMENT SPACING- FRONT VIEWCSCALE: 3/4" = 1'-0" UNIRAC SFM 8" ATTACHED SPLICE LANDSCAPE PORTRAIT BOTTOM STANDOFF DETAILBSCALE: 3" = 1'-0" MIDDLE/TOP STANDOFF DETAILASCALE: 3" = 1'-0" UNIRAC SFM INFINITY REC SOLAR REC420AA PURE-R PV MODULE UNIRAC SFM MICRORAIL/ SPLICE (E) ROOF SHEATHING FLASHING UNIRAC SFM SLIDER (1) 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE 212" MIN. EMBED. REC SOLAR REC420AA PURE-R PV MODULE (E) ROOF SHEATHING FLASHING UNIRAC SFM SLIDER AND TRIMRAIL ROOF ATTACHMENT (1) 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE 212" MIN. EMBED. UNIRAC SFM TRIMRAIL 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 STRUCTURAL PV4 STRUCTURAL INFORMATION: ROOF TYPE (1): ROOF TYPE: Comp Shingle SHEATHING TYPE: OSB FRAMING TYPE: Manufactured Truss FRAMING SIZE: 2x4 @ 24" OC CEILING JOIST SIZE: 2x4 @ 24" OC ATTACHMENT: SFM Infinity Flashkit RACKING: Unirac SFM Infinity @ 24" OC Portrait / 48" OC Landscape NUMBER OF ATTACHMENTS: 82 PV MODULE COUNT: 22 Modules TOTAL ARRAY AREA: 448.8 ft² (20.4ft²/panel) TOTAL ROOF AREA: 3031 ft² ARRAY/ROOF AREA: 14.8% ARRAY WEIGHT: 1,100 lbs (50 lbs/panel) DISTRIBUTED LOAD: 2.45 lbs/ft² POINT LOAD: 13.41 lbs/attachment STRUCTURAL NOTES: None *NOTE: LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY BASED ON FIELD CONDITIONS. MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER ENGINEER OF RECORD SPECIFICATIONS. -RACKING ATTACHMENTS TO BE STAGGERED UTILITY COMPANY: Dakota Electric Association PERMIT ISSUER: City of Lakeville ELECTRICAL NOTES:DESIGNER NOTES: LOAD SIDE BREAKER IN MSP. INTERIOR POI. (1) CIRCUIT OF 11 MODULES (1) CIRCUIT OF 11 MODULES JB-1L1 L2 EGC L1 L2 (N) 20A / 2P L1 L2 EGC 12 JB JB-1L1 L2 EGC L1 L2 (N) 20A / 2P L1 L2 EGC 12 EGC N G 15A / 2P ENVOY (22) REC Solar REC420AA PURE-R UL 1703 COMPLIANT (22) Enphase IQ7X-96-2-US 1 PHASE, UL 1741 COMPLIANT ENPHASE IQ COMBINER 4 X-IQ-AM1-240-4 (SOLAR LOAD ONLY) 3 JB-1 EZ SOLAR JUNCTION BOX 4"x4"x4" PVC JUNCTION BOX UTILITY PV PRODUCTION METER EGC L1 L2 N 15 PV AC DISCONNECT NON-FUSED LOCKABLE, VISIBLE OPEN 60A, 240V, 2-POLE L1 L2 N EGC 15 LINE LOAD 120/240 VAC 60HZ 1 PHASE TO UTILITY GRID L2 L1 N (E) 200A / 2P (N) 40A / 2P (E) LOADS (E) GROUNDING ELECTRODE(S) L2 L1 N EGC (E) 200A MAIN SERVICE PANEL (E) 200A / 2P MAIN BREAKER N G 15 *PV BREAKER TO BE LOCATED AT OPPOSITE END OF BUSSING FROM MAIN BREAKER INTERCONNECTION NOTES 705.12(B)(3) THE FOLLOWING METHOD(S) SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS: (2) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER-SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT EXCEED 12O PERCENT OF THE AMPACITY OF THE BUSBAR. IF REQUIRED, VERIFICATION WILL BE DONE TO ENSURE THE GROUNDING ELECTRODE SYSTEM IS CONGRUENT WITH CURRENT REQUIREMENTS. (NEC 250 PART III) IF NOT, A NEW GROUND ROD WILL BE INSTALLED. (N) 58" COPPER GROUND ROD, 8' LONG, MIN. 6' FROM (E) GROUNDING CONDUCTOR. GEC INSTALLED PER NEC 250.64: 6 OR 4 AWG SOLID COPPER GEC. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ELECTRICAL PV5 GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690.47] AND [NEC 250.50-60] SHALL BE PROVIDED. PER [NEC 690.47], THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64(C)]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF 4 AWG OR LARGER). 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM 8 AWG WHEN INSULATED, 6 AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH [NEC 250.134] OR [NEC 250.136(A)] REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS. 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR). 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES (NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH [NEC 110.2,110.3(A-B)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC-ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED. 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8] FOR MULTIPLE CONDUCTORS. 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8" ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE 310.15(B)(3)(A)],& [NEC 310.15(B)(3)(C)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY * USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE-2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING MEANS SHALL COMPLY WITH [NEC 690.13] AND [NEC 690.15]. 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH [NEC 230.6(4)] AND SECURED NO GREATER THAN 6' APART PER [NEC 330.30(B)]. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ELEC CALCS PV6 LABEL 1 FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [2017 NEC 690.13(B)] [2020 NEC 690.13(B)] LABEL 2 SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. [2017 NEC 690.54] [2020 NEC 690.54] LABEL 3 IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABEL ANYWHERE THAT IS POWERED BY BOTH THE UTILITY AND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANEL AND SUBPANELS. [2017 NEC 705.12(B)(3)] [2020 NEC 705.12(B)(3)] LABEL 4 APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER SOURCE. [2017 NEC 705.12(B)(2)(3)(b)] [2020 NEC 705.12(B)(3)(2)] LABEL 5 APPLY TO THE PV COMBINER BOX [2017 NEC 705.12(B)(2)(3)(c)] [2020 NEC 705.12(B)(3)(3)] LABEL 6 BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. [2017 NEC 690.56(C)(1)(a)] [2020 NEC 690.56(C)] LABEL 7 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [2017 NEC 690.56(C)(3)] [2020 NEC 690.56(C)(2)] LABEL 8 PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. [2017 NEC 705.10] [2020 NEC 705.10] LABEL 9 PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. [2017 NEC 705.10] [2020 NEC 705.10] LABEL 10 PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUTDOWN DISCONNECTING SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [2017 NEC 705.10 AND 690.56(C)(1)(a)] [2020 NEC 705.10 AND 690.56(C)] LABEL 11 PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT AC COMBINER PANEL. [2017 NEC 110.21(B)] [2020 NEC 110.21(B)] ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! PHOTOVOLTAIC SYSTEM AC DISCONNECT!! 240 VNOMINAL OPERATING AC VOLTAGE RATED AC OUTPUT CURRENT 28.82 A DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRICPV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAIN DISTRIBUTION UTILITY DISCONNECT(S) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY WITH A RAPID SHUTDOWN DISCONNECTING MEANS GROUPED AND LABELED WITHIN LINE OF SITE AND 10 FT OF THIS LOCATION WARNING! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED WARNING! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. SOLAR ARRAY RAPID SHUTDOWN DISCONNECT IS LOCATED OUTSIDE NEXT TO THE UTILITY METER. WARNING! PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS WARNING! 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 LABELS PV7 ADDITIONAL LABELS *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. UTILITY METER MAIN SERVICE PANEL 1 6 2 3 IF BREAKER IS USED4 8 10OR OR PLACARD SUBPANEL (IF INTERCONNECTION IS MADE HERE) 1 6 2 3 4 9 AC DISCONNECT 1 2 7 9 OR PLACARD PV COMBINER BOX 1 2 5 8 11 PV METER (IF APPLICABLE) LABELING NOTES 1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2) LABELING REQUIREMENTS BASED ON THE 2017 & 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535. 3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. 4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] STANDARD LABELS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nathan Clausen19151 Huxley AveLakeville Minnesota 55044AC SYSTEM SIZE: 6.908 kW ACDC SYSTEM SIZE: 9.24 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore August 3, 2023 785097 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 PLACARD PV8 DIRECTORY PLACARD NOTES [NEC 705.10] A PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. THE MARKING SHALL COMPLY WITH [110.21(B)]. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS Product Specifications αexperience performance 9 A module Current compatible with MLPE wp430 20.7 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT22.3%Efficiency rec Alpha Pure-R SERIES COMPACT PANEL Size Ref: PD-DS-AAPR Rev 3.1 03.23 STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Lead-Free GR GR GR GR GR 11±0.2[0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2[0.24±0.01] 1700 [67]1700 [67] Lorem ipsum 1730±2.5 [68.1±0.1] 880 [34.6]425 [16.7]1077±2.5 [42.4±0.1]22.5 [0.9] 594±3 [23.4±0.12] 1118±2.5 [44.0±0.1]17 [0.7]45 [1.8] 30 [1.2]REC Solar PTE. LTD.20 Tuas South Ave. 14Singapore 637312post@recgroup.comwww.recgroup.com Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. Available from: LOW LIGHT BEHAVIOUR Irradiance (W/m²)Rel. Efficiency (%)ELECTRICAL DATA Product Code*: RECxxxAA PURE-R Power Output - PMAX (Wp) 400 410 420 430 Watt Class Sorting - (W)0/+10 0/+10 0/+10 0/+10 Nominal Power Voltage - VMPP (V) 48.8 49.4 50.0 50.5 Nominal Power Current - IMPP (A) 8.20 8.30 8.40 8.52 Open Circuit Voltage - VOC (V) 58.9 59.2 59.4 59.7 Short Circuit Current - ISC (A) 8.80 8.84 8.88 8.91 Power Density (W/ft2)19.26 19.74 20.22 20.70 Panel Efficiency (%) 20.7 21.2 21.8 22.3 Power Output - PMAX (Wp)305 312 320 327 Nominal Power Voltage - VMPP (V) 46.0 46.6 47.1 47.6 Nominal Power Current - IMPP (A) 6.64 6.70 6.80 6.88 Open Circuit Voltage - VOC (V) 55.5 55.8 56.0 56.3 Short Circuit Current - ISC (A) 7.11 7.16 7.20 7.24 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. REC Alpha PURE-R Series Product SPECIFICATIONS CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-free acc. to RoHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 Measurements in inches [mm] GENERAL DATA Cell type:80 half-cut REC bifacial, heterojunction cells with lead-free, gapless technology Glass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:4-part, 4 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (12 AWG) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 67 + 67 in (1.7 + 1.7 m) in accordance with EN 50618 Dimensions:68.1 x 44.0 x 1.2 in (20.77 ft2) / 1730 x 1118 x 30 mm (1.93 m2) Weight:47.4 lbs (21.5 kg) Origin:Made in Singapore Specifications subject to change without notice.Typical low irradiance performance of module at STC: DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:858 (26 pallets) Panels per 53 ft truck:858 (26 pallets) WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply TEMPERATURE RATINGS* Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.24 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values MAXIMUM RATINGS Operational temperature:-40 ... +85°C System voltage:1000 V Test load (front): + 7000 Pa (146 lbs/ft2)* Test load (rear):- 4000 Pa (83.5 lbs/ft2)* Series fuse rating:25 A Reverse current:25 A * See installation manual for mounting instructions.Design load = Test load / 1.5 (safety factor) 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS The high-powered, smart grid-ready IQ7X Microinverter dramatically simplifies the installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase Energy System, the IQ7X Microinverter integrates with the IQ Gateway, IQ Battery, and the Enphase Installer App monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25-years. IQ7X Microinverter To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014, 2017 & 2020) Efficient and Reliable • Optimized for high powered 96-cell* modules • Highest CEC efficiency of 97.5% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid-Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) * The IQ7X is required to support 96-cell modules. IQ7X-DS-0099-EN-US-12-27-2022 1. Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ7, IQ7+, IQ Battery, Enphase Installer App, IQ Gateway, and other trademarks or service names are the trademarks of Enphase Energy, Inc. INPUT DATA (DC)IQ7X-96-2-US Commonly used module pairings¹320W - 460W Module compatibility 96-cell PV modules Maximum input DC voltage 79.5V Peak power tracking voltage 53V - 64V Operating range 25V - 79.5V Min/Max start voltage 33V/79.5V Max DC short circuit current (module Isc)10A Overvoltage class DC port II DC port backfeed current 0A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)@ 240VAC @ 208VAC Peak output power 320VA Maximum continuous output power 315VA Nominal (L-L) voltage/range²240V/211-264V 208V/183-229V Maximum continuous output current 1.31A (240VAC)1.51A (208VAC) Nominal frequency 60 Hz Extended frequency range 49 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20A (L-L) branch circuit³ 12 (240VAC)10 (208VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging EFFICIENCY @240VAC @208VAC CEC weighted efficiency 97.5 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7X-96-2-US)MC4 (or Amphenol H4 UTX with optional Q-DCC-5 adapter) Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enphase Installer App and monitoring optionsCompatible with IQ Gateway Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB, 3rd Ed.)HEI Rule 14H SRD 2.0UL 62109-1, FCC Part 15 Class B, ICES-0003 Class B,CAN/CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020, section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. IQ7X Microinverter IQ7X-DS-0099-EN-US-12-27-2022 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS 125 & 200 Amp 011 (closed)U204 (open)Single Meter Sockets Without Bypass Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Single Meter Sockets - Without Bypass Application • Single meter position • Receive ANSI C12.10 watthour meters • Surface or flush mount (see chart) Construction • Ring type • NEMA Type 3R • ANSI 61 gray painted finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - see chart • ANSI C12.7 • AW Hub 4 B-Line series meter mounting equipmentEaton Part/UPCNumber CatalogNumber AmpRating Jaws ServiceType Access Connections Overall Dimensions TopProvision KnockoutLayout 5th JawKitLineLoadNeutralHeightWidthDepth 78205142000 011 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11"81/4"35/8"AW Hub Fig.5 MSR5TK 78205142040 011 F 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12"8"45/8"2" max KO Fig. 1 50365 78205142045 011 MS73 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11"81/4"35/8"AW Hub Fig. 5 MSR5TK 78205142050 011 SF 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12"8"45/8"None None 50365 78205102315 011 SS 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12"8"45/8"None None 50365 79903882585 011 SS6 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12"8"45/8"None None 50365 79903882586 011 MS25A 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12"8"45/8"AW Hub Fig. 1 50365 79903856283 011 MS25 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12"8"45/8"AW Hub Fig. 1 50365 79903868944 011 MS-18 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11"81/4"35/8"AW Hub Fig.5 MSR5TK 79903878861 011 SRP 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11"81/4"35/8"AW Hub Fig.5 MSR5TK 79903878953 011 SRP MS18 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11"81/4"35/8"AW Hub Fig.5 MSR5TK 78205144030 927 100 7 3Ø/4W OH/UG #14 - 1/0 #14 - 2/0 #14 - 2/0 17"8"45/8"AW Hub Fig. 1 50365 78205156000 204 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"45/8"AW Hub Fig. 2 50365 78205156020 204 F 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"6"2" max KO Fig. 2 50365 78205108796 204 SS 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"6"None None 50365 79903882318 U204 PSE 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"None Fig. 7 50365 78205122640 U204 F SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"None None 50365 78205134301 U204 SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"None None 50365 78205153193 U204 MS73 SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"None None 50365 78205156080 U204 MS21 SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"None None 50365 78205156030 204 F MS73 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"6"2" max KO Fig. 2 50365 78205156040 204 MS68 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"45/8"AW / 2" Hub Fig. 2 50365 78205156035 204 MS68A 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"45/8"AW / 2" Hub Fig. 2 50365 78205108490 204 MS73 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"8"45/8"AW Hub Fig. 2 50365 78205156005 U204 200 4 1Ø/3W UG #6 - 350MCM #6 - 350MCM #6 - 350MCM 151/8"111/4"41/2"None Fig. 6 MSR5TK 78205156045 U204 F 200 4 1Ø/3W OH/UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"(2) 2" max KO Fig. 3 50365 78205156060 U204 MS21 200 4 1Ø/3W OH/UG #6 - 350MCM #6 - 350MCM #6 - 350MCM 151/8"111/4"41/2"AW / Cap Fig. 6 MSR5TK 78205156060 U204 F MS73 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15"12"6"None Fig. 3 50365 78205156070 U204 MS73 200 4 1Ø/3W OH/UG #6 - 350MCM #6 - 350MCM #6 - 350MCM 151/8"111/4"41/2"(2) 2" max KO Fig. 6 MSR5TK 78205156140 U207 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 18"12"5"AW Hub Fig. 4 50365 78205156170 U207 F 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 18"12"5"21/2" max KO Fig. 4 50365 78205156180 U207 MS73 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 18"12"5"AW Hub Fig. 4 50365 Knockouts - Conduit Sizes 1W = 1⁄4" 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4D = 11⁄4" - 1" - 3⁄4" - 1⁄2" 4E = 11⁄2" - 11⁄4" - 1" - 3⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1" 4G = 21⁄2" - 2" - 11⁄2" - 11⁄4" 4H - 3" - 21⁄2" - 2" - 11⁄2" 6G = 21⁄2" - 2" - 11⁄2" - 11⁄4" - 1" - 3⁄4" Top Provision = See Chart Knockout Layouts 125 & 200 Amp Single Meter Sockets Without Bypass Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Single Meter Sockets - Without Bypass Style #Suffixes 011 F - Flush Mount (U) 207 MS18 - Lexan Cover (U) 204 MS21 - Top Hub Provision (U) 207 MS25 - Solar Ready (U) 207 MS25A - MS25 + MS18 927 MS68 - 2" Conduit Hub MS68A - MS73 + MS68 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel 304 * SS6 - Stainless Steel 316 * 5B-Line series meter mounting equipment Eaton * Knockouts and top provisions are not available in Stainless Steel (SS) finish Fig. 1 Fig. 6 Top Provision Top Provision Fig. 2 Fig. 4 2A Top ProvisionTop Provision 1A 4F 4F 4Fbothsides 1A 6G 4G 4G 1W 4G 4G 4G4G 4G 6Gbothsides4Gbothsides 1A 4F 4F 4Fbothsides Fig. 3 Top Provision 1W 4F 4G 4G 4F 4Fbothsides Fig. 5 Top Provision 1A 4E 4F 4Ebothsides 4D4D Fig. 7 Top Provision 1A 4F 4H 4F 4G 4Fbothsides 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS WIRING DIAGRAMS ~7.25 .28 DIA NOT FUSIBLE ~ [7) (3 HOLES) r-=-o / l AH B }H ' :n ~ .,./ 1 '~:· b3 9.63 rl [24-5] TERMif'W.. LUGS * N.tPERES MAX. WIRE MIN. WIRE lYPE ........--f.--A,B,C #2AWG #10 AWG AL ::!)}: KNOCKOUTS 60 :.~: ~~:.... (~ #2AWG #14 AWG cu -·-......___A,B,c KNOCKOUTS KNOCKOUTS _4.5~,-L3.7~-SYMBOL A • c D [114] [95] CONDUIT SIZE .50 .75 1 1.25 17.75 NEMA TYPE 3R [197] J A.B.~~ fOl KNOCKOUTS 16 ~ 6 ~:",8,C,D . INCHES DUAL DIMENSIONS. MILUMETERS KNOCKOUTS HORSEPOWER RATINGS CATALOC WIRING 240VAC NUMBER VOLTAGE RAllNGS , .... MAX. 10 JO DU222RB 24fNAC A 10 - NOTES: DU322RB 24fNAC • 10 15 FINISH -GRAY BAKED ENAMEL UL LISTED -FILE E-2B75 SUITABLE FOR USE AS SERVICE EQUIPMENT TOP OF NEMA TYPE 3R SWITCHES HA.VE PRO'Y1SIONS FOR MAXIMUM 2 1/2N BOLT-ON HUB. GENERAL DUTY SAFETY SWITCHES ~ a• IAFE D SHORT CIRCUIT CURRENT RATINGS: VlSIBLE BLADE TYPE Schneider Electric 10,000 AMPERES WHEN USED WITH OR PR01ECTED BY CLASS H OR K FUSES 60 AMPERE 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES. ENCLOSURE -NEMA TYPE JR RAINPROOF :j: LUGS SUITABLE FOR 60'C OR 75"C COPPER OR ALUUINU~ CONDUCTORS. :w.' 1861 DECEMBER 2004 REF DWG #1861 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SSPROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR.ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. Phone: 385-202-4150 www.ezsolarproducts.com ITEM No. 1 1 1 6 6 JB-1.2 Body POLYCARBONATE WITH UV INHIBITORS POLYCARBONATE WITH UV INHIBITORS #10 x 1-1/4” Phillips pan head screw #8 x 3/4” Phillips pan head screw JB-1.2 Lid2 3 4 PART NUMBER DESCRIPTION QTY Size SCALE: 1:2 WEIGHT: 1.45 LBS SHEET 1 of 3 DWG. NO.RevBJB-1.2 Torque Specification: certification: WEIGHT: 15-20 LBS 1.45 LBS UL Standard 1741, nema 3r JB-1.2Specification Sheet PV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: 80 Amps • Allowable Wire: 14 AWG – 6 AWG • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 – 12:12 • Max Side Wall Fitting Size: 1” • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741 - Approved wire connectors: must conform to UL1741 • System Marking: Interek Symbol and File #5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. A. System Specifications and Ratings Phone: 385-202-4150 | www.ezsolarproducts.com 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS www.carlon.com180 Rigid Nonmetallic Conduit – Junction Boxes Molded Nonmetallic Junction Boxes 6P Rated It’s another first from Carlon®- the first nonmetallic junction boxes UL Listed with a NEMA 6P rating per Section 314.29, Exception of the National Electrical Code. Manufactured from PVC or PPO thermoplastic molding compound and featuring foam-in-place gasketed lids attached with stainless steel screws, these rugged enclosures offer all the corrosion resistance and physical properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor use, primarily to provide a degree of protection against contact with enclosed equipment, falling dirt, hose- directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. • All Carlon Junction Boxes are UL Listed and maintain a minimum of a NEMA Type 4/4x Rating. • Parts numbers with an asterisk (*) are UL Listed and maintain a NEMA Type 6P Rating and Type 4/4X Rating. E42728Except where noted by † Size in Std.Material Std. Inches Ctn. Min Min. Min. Min. Ta Tc Thermo-Ctn. Part No.H x W x D Qty.AT AB B C PVC plastic Wt. (Lbs.) E989NNJ-CAR*4 x 4 x 2 5311/16 35/8 N/A 2 .160 .155 X3 E987N-CAR* 4 x 4 x 4 5 3 11/16 31/2 N/A 4 .160 .155 X 4 †E989NNR-CAR*4 x 4 x 6 4311/16 33/8 N/A 6 .160 .200 X 5 E989PPJ-CAR* 5 x 5 x 2 4 411/16 41/2 N/A 2 .110 .150 X 3 E987R-CAR*6 x 6 x 4 2 6 5 5/8 N/A 4 .190 .190 X 3 E989RRR-UPC* 6 x 6 x 6 8 5 5/8 53/8 N/A 6 .160 .150 X 14 E989N-CAR 8 x 8 x 4 1 8 8 N/A 4 .185 .190 X 2 E989SSX-UPC 8 x 8 x 7 2721/32 75/16 N/A 7 .160 .150 X 6 E989UUN 12 x 12 x 4 3 115/8 111/2 111/8 4 .160 .150 X 12 E989R-UPC 12 x 12 x 6 2 11 15/16 117/8 117/16 6 .265 .185 X 10 Typical Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com DRAWING NUMBER: SS BLUE RAVEN ]ILAR SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. SFM INFINITY 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre-assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. SYSTEM OVERVIEW BONDING AND ACCESSORIES 2MW 3MW PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules 2 3 4 5 6 1 1 4 3 5 6 7 SFM INFINITY 15 Attachments RAIL 20 Attachments 87%OF HOMEOWNERS PREFER MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. 7 2 PART NAME DESCRIPTION TRIMRAIL Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post-install array leveling. SPLICE Connects and supports modules. Provides east-west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. DRAWING NUMBER: SS BLUE RAVEN ]ILARSFMSUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 8FLASHKIT MOUNTING PILOT HOLES: Drill pilot holes for lag screws or structural screws (as necessary) at marked attachment points FLASHINGS: Place fl ashings INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • Insert fl ashings per manufacturer instructions NOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" • Attach sliders to rafters • Verify proper row to row spacing for module size (Mod NS + 1") • Ensure that Trimrail™roof attachments in each row have suffi cient engagement with slider dovetails for proper attachment. INSTALL SLIDERS AND ROOF ATTACHMENTS: Follow manufacturer instructions for fl ashing installation procedures NOTE: If N-S module edge is within 1” of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required. UP-SLOPE DOWN-SLOPE Mod NS + 1" Mod NS + 1" N/S MODULE EDGE Rotate Slider Cut Shingles as Required Less Than 1" DRAWING NUMBER: SS BLUE RAVEN ]ILARSFMSUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 11TRIMRAIL & MICRORAIL INSTALLATION ATTACH TRIMRAIL TO ROOF ATTACHMENT: Attach rail using 3/8" hex bolt & Tri-drive or serrated fl ange nuts. Make sure TrimrailTM is level across all TrimrailTM roof attachments. After rail is level, tighten channel clamp bolts to secure TrimrailTM roof attachments to channels. POSITION MODULE CLIPS ACCORDING TO MODULE THICKNESS: Align notch in module clip with trimrail rib according to module thickness (identifi ed in mm on faces of module clips). Rotate clip to position at required location. INSTALL MODULE CLIPS ON TRIMRAIL: Attach module clips to Trimrail using 3/8" T-bolts and Tri-drive or serrated fl ange nuts. A minimum of two clips are required per module. Refer to SFM D&E guide and U-builder for required position and quantity of module clips. INSTALL MICRORAILS: Install MicrorailTM at marked attachment points. Click MicrorailTM into sliders and push MicrorailTM to top of slider. Ensure that cap remains in upper most (40mm) position. NOTE: module clips may be pre-installed on trimrail prior to attaching trimrail to roof attachments NOTE: Bonding pin on Microrails should be positioned downslope.BONDING PIN DRAWING NUMBER: SS BLUE RAVEN ]ILARSFMSUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 19SYSTEM BONDING & GROUNDING E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. TRIMRAIL BONDING PATH: Trimrail to module bonding is accomplished with bonding clamp with integral bonding pin and bonding T-bolt. (refer also to alternate method) N-S BONDING PATH: N-S module to module bonding is accomplished with bonding clamp with 2 integral bonding pins. (refer also to alternate method) System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module at a location on the module specifi ed by the module manufacturer. LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) • 10-32 mounting hardware • Torque = 5 ft-lb • AWG 4-14 - Solid or Stranded LUG DETAIL & TORQUE INFO Ilsco Flange Lug (SGB-4) • 1/4” mounting hardware • Torque = 75 in-lb • AWG 4-14 - Solid or Stranded LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • 1/4” mounting hardware • Torque = 10 ft-lb • AWG 6-14 - Solid or Stranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs WEEBLUG Single Use Only Star Washer is Single Use Only Alternate method Alternate method DRAWING NUMBER: SS BLUE RAVEN ]ILARSFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 20UL CODE COMPLIANCE NOTES SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to the system level fire portion of UL 1703. This UL 1703 classification has been incorporated into the UL 2703 product certification. SFM has achieved Class A, B & C system level performance for low slope & steep sloped roofs when used in conjunction with type 1 and type 2 modules. Class A, B & C system level fire UL2703 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure – 113 PSF / 5400 Pa b) Upward Pressure – 50 PSF / 2400 Pa c) Down-Slope Load – 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure – 170 PSF / 8000 Pa b) Upward Pressure – 75 PSF / 3500 Pa c) Down-Slope Load – 32.4 PSF / 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required performance is inherent in the SFM design, and no additional mitigation measures are required. The fire classification rating is valid for any roof pitch. There is no required minimum or maximum height limitation above the roof deck to maintain the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTM components shall be mounted over a fire resistant roof covering rated for the application. DRAWING NUMBER: SS BLUE RAVEN ]ILARSFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 21UL CODE COMPLIANCE NOTES LABEL MARKINGS • System fire class rating: See installation instructions for installation requirements to achieve a specified system fire class rating with Unirac. • Unirac SUNFRAME MICRORAILTM is listed to UL 2703. • All splices within a system are shipped with marking indicating date and location of manufacture. DRAWING NUMBER: SS BLUE RAVEN ]ILARSFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 22TESTED / CERTIFIED MODULE LIST Aleo P-Series Aptos DNA-120-(BF/MF)26 DNA-144-(BF/MF)26 Astronergy CHSM6612P, CHSM6612P/HV, CHSM6612M, CHSM6612M/HV, CHSM6610M (BL)(BF)/(HF), CHSM72M-HC Auxin AXN6M610T, AXN6P610T, AXN6M612T & AXN6P612T Axitec AXIblackpremium 60 (35mm), AXIpower 60 (35mm), AXIpower 72 (40mm), AXIpremium 60 (35mm), AXIpremium 72 (40mm). Boviet BVM6610, BVM6612 BYD P6K & MHK-36 Series Canadian Solar CS1(H/K/U/Y)-MS CS3(K/L/U), CS3K-MB-AG, CS3K-(MS/P) CS3N-MS, CS3U-MB-AG, CS3U-(MS/P), CS3W CS5A-M, CS6(K/U), CS6K-(M/P), CS6K-MS CS6P-(M/P), CS6U-(M/P), CS6V-M, CS6X-P Centrosolar America C-Series & E-Series CertainTeed CT2xxMxx-01, CT2xxPxx-01, CTxxxMxx-02, CTxxxM-03, CTxxxMxx-04, CTxxxHC11-04 Dehui DH-60M Manufacture Module Model / Series Eco Solargy Orion 1000 & Apollo 1000 ET Solar ET-M672BHxxxTW Freedom Forever FF-MP-BBB-370 FreeVolt Mono PERC GCL GCL-P6 & GCL-M6 Series Hansol TD-AN3, TD-AN4, UB-AN1, UD-AN1 Heliene 36M, 60M, 60P, 72M & 72P Series, 144HC M6 Monofacial/ Bifacial Series, 144HC M10 SL Bifacial HT Solar HT60-156(M) (NDV) (-F), HT 72-156(M/P) Hyundai KG, MG, TG, RI, RG, TI, MI, HI & KI Series HiA-SxxxHG ITEK iT, iT-HE & iT-SE Series Japan Solar JPS-60 & JPS-72 Series JA Solar JAP6 60-xxx, JAM6-60-xxx/SI, JAM6(K)-60/ xxx, JAP6(k)-72-xxx/4BB, JAP72SYY-xxx/ZZ, JAP6(k)-60-xxx/4BB, JAP60SYY-xxx/ZZ, JAM6(k)-72-xxx/ZZ, JAM72SYY-xxx/ZZ, JAM6(k)-60-xxx/ZZ, JAM60SYY-xxx/ZZ. i. YY: 01, 02, 03, 09, 10 ii. ZZ: SC, PR, BP, HiT, IB, MW, MR Jinko JKM & JKMS Series Eagle JKMxxxM JKMxxxM-72HL-V Kyocera KU Series Manufacture Module Model / Series Manufacture Module Model / Series • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information LG Electronics LGxxxN2T-A4 LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ Q1C/Q1K/S1C/S2W)-A5 LGxxxN2T-B5 LGxxxN1K-B6 LGxxx(A1C/M1C/M1K/N1C/N1K/Q1C/Q1K/ QAC/QAK)-A6 LGxxx(N1C/N1K/N2T/N2W)-E6 LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 LGxxxN2T-J5 LGxxx(N1K/N1W/N2T/N2W)-L5 LGxxx(N1C/Q1C/Q1K)-N5 LGxxx (N1C/N1K/N2W/Q1C/Q1K)-V5 LONGi LR4-60(HIB/HIH/HPB/HPH)-xxxM LR4-72(HIH/HPH)-xxxM LR6-60(BP/HBD/HIBD)-xxxM (30mm) LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM (35mm) LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) Mission Solar Energy MSE Series Mitsubishi MJE & MLE Series Neo Solar Power Co.D6M & D6P Series DRAWING NUMBER: SS BLUE RAVEN ]ILARSFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE 23TESTED / CERTIFIED MODULE LIST REC Solar (cont.) TwinPeak Series TwinPeak 2 Series TwinPeak 2 BLK2 Series TwinPeak 2S(M)72(XV) TwinPeak 3 Series (38mm) TP4 (Black) Renesola Vitrus2 Series & 156 Series Risen RSM72-6 (MDG) (M), RSM60-6 SEG Solar SEG-xxx-BMD-HV SEG-xxx-BMD-TB S-Energy SN72 & SN60 Series (40mm) Seraphim SEG-6 & SRP-6 Series Sharp NU-SA & NU-SC Series Silfab SLA, SLG, BC Series & SILxxx(BL/NL/NT/HL/ ML/BK/NX/NU/HC) Solarever USA SE-166*83-xxxM-120N Solaria PowerXT-xxxR-(AC/PD/BD) PowerXT-xxxC-PD PowerXT-xxxR-PM (AC) SolarWorld Sunmodule Protect, Sunmodule Plus Sonali SS-M-360 to 390 Series, SS-M-390 to 400 Series, SS-M-440 to 460 Series, SS-M-430 to 460 BiFacial Series, SS 230 - 265 SunEdison F-Series, R-Series & FLEX FXS Series Manufacture Module Model / Series Suniva MV Series & Optimus Series SunPower A-Series A400-BLK , SPR-MAX3-XXX-R, X-Series, E-Series & P-Series Suntech STP, STPXXXS - B60/Wnhb Talesun TP572, TP596, TP654, TP660, TP672, Hipor M, Smart Tesla SC, SC B, SC B1, SC B2 TxxxH, TxxxS Trina PA05, PD05, DD05, DE06, DD06, PE06, PD14, PE14, DD14, DE09.05, DE14, DE15, PE15H Upsolar UP-MxxxP(-B), UP-MxxxM(-B) United Renewable Energy (URE) D7MxxxH7A, D7(M/K)xxxH8A FAKxxx(C8G/E8G), FAMxxxE7G-BB FAMxxxE8G(-BB) FBMxxxMFG-BB Vikram Eldora, Solivo, Somera Waaree AC & Adiya Series Winaico WST & WSP Series Yingli YGE & YLM Series ZN Shine ZXM6-72, ZXM6-NH144-166_2094 Manufacture Module Model / Series Manufacture Module Model / Series • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information Panasonic EVPVxxx (H/K/PK), VBHNxxxSA15 & SA16, VBHNxxxSA17 & SA18, VBHNxxxSA17(E/G) & SA18E, VBHNxxxKA01 & KA03 & KA04, VBHNxxxZA01, VBHNxxxZA02, VBHNxxxZA03, VBHNxxxZA04 Peimar SGxxxM (FB/BF) Phono Solar PS-60, PS-72 Prism Solar P72 Series Q.Cells Plus, Pro, Peak, G3, G4, G5, G6(+), G7, G8(+) Pro, Peak L-G2, L-G4, L-G5, L-G6, L-G7 Q.PEAK DUO BLK-G6+ Q.PEAK DUO BLK-G6+/TS Q.PEAK DUO (BLK)-G8(+) Q.PEAK DUO L-G8.3/BFF Q.PEAK DUO (BLK) ML-G9(+) Q.PEAK DUO XL-G9/G9.2/G9.3 Q.PEAK DUO (BLK) ML-G10(+) Q.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Q.PEAK DUO BLK ML-G10+ / t REC Solar Alpha (72) (Black) (Pure) RECxxxAA PURE-R RECxxxNP3 Black N-Peak (Black) N-Peak 2 (Black) PEAK Energy Series PEAK Energy BLK2 Series PEAK Energy 72 Series