HomeMy WebLinkAboutLA214619 - 17170 Judicial Rd Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
PROJECT CONTACT LIST
RONGITSCH CONSTRUCTION INC.
CONTACT: MIKE RONGITSCH
ADDRESS: 10561 165TH ST. W. LAKEVILLE, MN 55044
EMAIL: MIKE@RONGITSCH.COM
PHONE: 612-581-3790
GENERAL CONTRACTOR
KAEDING ARCHITECTURE
CONTACT: JENNIFER KAEDING
ADDRESS: 235 WEST MAIN STREET, SUITE 201, WACONIA, MN 55387
EMAIL: JKAEDING@KAEDINGARCH.COM
PHONE: 952-451-9763
ARCHITECT
PROJECT
SITE
GENERAL NOTES
1. THESE DRAWINGS MAKE UP THE "ARCHITECTURAL SET" OF THE CONTRACT
DOCUMENTS. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING
ADDITIONAL DETAILS REQUIRED FOR CONSTRUCTION.
2. WARRANTIES SHALL BE IN ACCORDANCE WITH STATE MINIMUM STANDARDS.
REGISTERED BUILDER PROGRAMS AND/OR PRODUCT WARRANTIES TO BE
PROVIDED BY PRODUCT MANUFACTURERS. LIABILITY AND WORKER'S
COMPENSATION CERTIFICATE OF INSURANCE WILL BE REQUIRED FROM ALL
SUBCONTRACTORS.
3. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY AND
COORDINATE ALL CONDITIONS AND DIMENSIONS PRIOR TO WORK. GENERAL
CONTRACTOR TO CONTACT GOPHER ONE TO VERIFY LOCATIONS OF ALL
UNDERGROUND ELECTRICAL, UTILITIES, SEWER, CABLE, GAS, ETC. PRIOR TO
COMMENCING WORK. IMMEDIATELY REPORT AND/OR REVIEW ALL QUESTIONS,
DISCREPANCIES, AND CONDITIONS WITH THE OWNER/ARCHITECT PRIOR TO
PROCEEDING WITH WORK.
4. ALL CONSTRUCTION AND/OR MATERIALS AS INDICATED SHALL BE AT OR ABOVE
INDUSTRY STANDARDS FOR SIMILAR CUSTOM RESIDENTIAL CONSTRUCTION.
5. ALL CONSTRUCTION WORK SHALL CONFORM TO ALL APPLICABLE CODES.
6. ALL SURVEY DATA, SOIL DATA, MECHANICAL, ELECTRICAL, AND STRUCTURAL
ENGINEERING OF SYSTEMS, SIZES, AND LAYOUTS (INCLUDING TRUSS FRAMING
AND GIRDER DESIGN) SHALL BE BY THE RESPECTIVE SUBCONTRACTOR AND/OR
SUPPLIER OF THOSE SYSTEMS OR BY OTHER NECESSARY CONSULTANTS AND SHALL
BE COORDINATED BY THE GENERAL CONTRACTOR. INFORMATION SHOWN IN
REGARD TO THESE CONCERNS IS ONLY DIAGRAMMATIC AND IS INTENDED TO
PROVIDE AND INDICATION OF THE DESIGN INTENT ONLY. USE OF CONSULTANT
DATA BY KAEDING ARCHITECTURE DOES NOT INFER NOR ENDORSE THE
ACCURACY OF THE DATA. EACH CONSULTANT AND CONTRACTOR SHALL BE
RESPONSIBLE FOR CORRECTNESS AND ACCURACY OF DATA SUPPLIED BY THE
RESPECTIVE CONSULTANT AND/OR CONTRACTOR.
7. GENERAL CONTRACTOR SHALL COORDINATE AT THE BUILDING SITE PER THE
RECENT LEGAL SURVEY. GENERAL CONTRACTOR SHALL NOTIFY OWNER/
ARCHITECT/ ENGINEER OF ANY DISCOVERED DISCREPANCIES PRIOR TO ANY SITE
WORK. DESIGN OF TOPOGRAPHY SHOWN DEPICTS DESIGN INTENT ONLY. FINAL
GRADING AND SITE DRAINAGE IS THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR AND LANDSCAPER. G.C./LANDSCAPER TO COORDINATE GRADING
AND DRAINAGE WITH NEIGHBORING PROPERTIES, LEGAL SURVEY, AND
APPLICABLE CODES.
8. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR SHORING AND
BRACING AND FOR ALL TEMPORARY FACILITIES AND SERVICES, INCLUDING BUT
NOT LIMITED TO POWER, WATER, TELEPHONE, SANITATION FACILITIES, SITE SAFETY,
AND FIRE FIGHTING EQUIPMENT.
9. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED EROSION
CONTROL MEASURES AND ANY SPECIFIC ENVIRONMENTAL IMPACT ISSUES
ARISING FROM CONSTRUCTION ON THE SITE.
10. GENERAL CONTRACTOR SHALL MAINTAIN THE SITE IN FIRST-CLASS CONDITION
DURING PROJECT. ALL WASTE AND DEBRIS SHALL PROMPTLY BE REMOVED.
CONSIDERATION SHALL BE GIVEN TO MATERIAL STORAGE ON THE SITE AND ITS
IMPACT ON ADJOINING NEIGHBORS.
11. GENERAL CONTRACTOR SHALL PROVIDE FINAL CLEANING OF ALL INTERIOR AND
EXTERIOR SURFACES. ALL TRANSPARENT MATERIALS AND GLOSSY SURFACES ARE
TO BE LEFT IN A POLISHED CONDITION. REMOVE ALL LABELS THAT ARE NOT
INTENDED TO REMAIN AS PERMANENT INSTRUCTION INFORMATION.
12. GENERAL CONTRACTOR SHALL PROVIDE INSTRUCTIONS TO THE OWNER
PERTAINING TO OPERATION AND MAINTENANCE OF MECHANICAL AND
ELECTRICAL EQUIPMENT. AT COMPLETION OF CONSTRUCTION, COMPILE AND
FORWARD TO THE OWNER ALL MAINTENANCE AND OPERATIONS DATA AND
WARRANTIES IN THE FORM OF A WELL-ORGANIZED OWNER'S NOTEBOOK.
13. ROOF TRUSS SYSTEM DESIGN TO BE PROVIDED BY TRUSS SUPPLIER. TRUSS SUPPLIER
TO COORDINATE FINAL TRUSS SOLUTION WITH PROJECT STRUCTURAL ENGINEER.
TRUSS SUPPLIER TO COORDINATE TRUSS DESIGN WITH ENERGY HEEL
REQUIREMENTS.
14. ALL WINDOW DESIGNATIONS ARE FOR GENERIC. SUPPLIER TO SUBMIT WINDOW
SCHEDULE TO GENERAL CONTRACTOR AND OWNER FOR REVIEW AND APPROVAL
PRIOR TO PLACING WINDOW ORDER. GENERAL CONTRACTOR TO CONFIRM
TEMPERED GLASS LOCATIONS, EGRESS AND VENT WINDOW REQUIREMENTS, LITE
PATTERNS, WINDOW SIZES, WINDOW OPERATION, JAMB SIZES, EXTENSION JAMBS,
ETC. W/OWNER PRIOR TO WINDOW ORDER. WINDOWS ARE TO BE PREFINISHED
METAL CLAD WINDOWS WITH DOUBLE-PANE, "LOW-E" INSULATED GLASS AND
SIMULATED DIVIDED LITES WITH SPACER BARS (SEE EXTERIOR ELEVATIONS FOR
MUNTIN LOCATIONS). PREFINISHED COLOR AND HARDWARE FINISH AS SELECTED
BY OWNER. ALTERNATE MANUFACTURERS' WINDOWS SHALL BE SIMILAR IN SIZE
AND SPECIFICATION TO THOSE INDICATED ON THE PLAN. WINDOW
MANUFACTURER SHALL SUBMIT SHOP DRAWINGS OF WINDOWS AND DOORS FOR
REVIEW BY GENERAL CONTRACTOR AND OWNER PRIOR TO FABRICATION.
15. CABINET DRAWINGS SHOWN HERE ARE NOT CABINET SHOP DRAWINGS, BUT
DEPICT DESIGN INTENT ONLY. CABINET MANUFACTURER TO COORDINATE FINAL
CABINET DESIGN WITH OWNER PREFERENCES, AS-BUILT DIMENSIONS (WITH FIELD
CHANGES MADE DURING CONSTRUCTION), FINAL MILLWORK PROFILES, FINAL
COUNTERTOP THICKNESSES AND DESIGNS, AND FINAL APPLIANCE AND FIXTURE
SELECTIONS. CABINET MAKER TO VERIFY END PANEL DESIGNS AND CABINET
CLEARANCES WITH OWNER PRIOR TO CABINET FABRICATION. CABINET MAKER TO
MEET WITH OWNER TO DISCUSS AND VERIFY ALL DRAWER AND CABINET
DIVISIONS AND USES, INCLUDING PULL-OUT LOCATIONS, LAZY SUSAN LOCATIONS,
COST RAMIFICATIONS, HARDWARE TYPES AND QUALITY, AND ANY OTHER
SUGGESTIONS THE CABINET MAKER OR OWNER MAY HAVE FOR MAXIMIZING
CABINETRY EFFICIENCY AND EASE OF USE.
16. SUBCONTRACTORS TO REFER TO OWNER-APPROVED CABINET SHOP DRAWINGS
PRIOR TO ROUGH FRAMING FOR CABINETS/ BUILT-INS. REPORT ANY
DISCREPANCIES TO G.C./CABINET MAKER PRIOR TO PROCEEDING WITH WORK.
GENERAL NOTES (CONTINUED)
17. GENERAL CONTRACTOR TO COORDINATE OWNER'S REVIEW AND APPROVAL OF
SAMPLES OF ALL INTERIOR AND EXTERIOR FINISH MATERIALS, INCLUDING
PROFILES, SIZES, SPECIES, MORTAR AND GROUT COLORS, JOINT SIZES, FINISHES,
AND COLORS PRIOR TO ORDERING OF SAME. SAMPLES TO BE PROVIDED ON-SITE
WHEN OWNER DEEMS NECESSARY, AND IN SIZES LARGE ENOUGH TO SEE IN THE
FINAL SPACES (EX. 4'x4' WALL PAINT SAMPLES, AND STAINED AND FINISHED 3-
BOARD WOOD FLOOR SAMPLES). G.C. TO COORDINATE OWNER'S REVIEW AND
APPROVAL OF FULL-SIZE MOCK-UPS OF ALL INTERIOR AND EXTERIOR CASINGS,
TRIM, NEWELS, AND RAILINGS PRIOR TO CONTRACTOR ORDERING OF SAME (ON-
SITE WHEN OWNER DEEMS NECESSARY). OWNER TO REVIEW AND APPROVE FULL-
SIZE MOCK-UPS OF ALL STONE ON SITE, INCLUDING STONE SIZE & SPECIES,
MORTAR JOINT SIZE, MORTAR COLOR, STONE STACKING, CAP SPECIES, AND SIZE.
STONE SAMPLES TO BE DISPLAYED ALONGSIDE RELEVANT INTERIOR AND EXTERIOR
FINISH MATERIALS, AS REQUIRED FOR FINAL COLOR PALLET COORDINATION. G.C.
TO COORDINATE OWNER'S COUNTERTOP SELECTIONS, AND TO VERIFY THAT
NATURAL STONE SLABS THAT OWNER SELECTS ARE PROPERLY STORED AND USED IN
THE FINAL PROJECT.
18. DIMENSIONS LOCATING EXTERIOR WALLS ARE TO THE EXTERIOR FACE OF STUD
AND/OR FACE OF FOUNDATION WALLS, U.N.O. DIMENSIONS LOCATING INTERIOR
WALLS ARE TO CENTERLINE OF STUD, U.N.O. DIMENSIONS LOCATING DOORS AND
WINDOWS ARE TO CENTERLINE OF OPENING, U.N.O. SEE DIMENSION KEYS ON
ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
19. ALL EXTERIOR WALLS SHALL BE 2x6 AS PER BUILDING SECTIONS, U.N.O. ALL
BEARING WALLS, PLUMBING WALLS, AND WALLS WITH POCKET DOORS TO BE 2x6
CONSTRUCTION, U.N.O. ALL OTHER WALLS TO BE 2x4 OR 2x6 CONSTRUCTION TO
THICKNESSES SHOWN ON ARCHITECTURAL AND STRUCTURAL DRAWINGS, U.N.O.
HEADERS SHALL BE SIZED PER STRUCTURAL PLANS, OR COORDINATED WITH
STRUCTURAL ENGINEER. BLOCKING AS REQUIRED FOR CABINETS, BATH AND
KITCHEN HARDWARE AND ACCESSORIES, HANDRAILS, ETC. VERIFY WITH G.C.
PRIOR TO FRAMING.
20. PROVIDE ACOUSTIC INSULATION AND PARTITIONS PER ARCHITECTURAL
DRAWINGS. CONTRACTOR TO VERIFY ADDITIONAL ACOUSTIC INSULATION,
CEILING ACOUSTIC INSULATION, AND ACOUSTIC PARTITION LOCATIONS WITH
OWNER PRIOR TO VAPOR BARRIER & DRYWALL INSTALLATION. ACOUSTIC
CONSIDERATION TO BE GIVEN TO HVAC DUCT LAYOUTS AND PLUMBING
LOCATIONS, AND ACOUSTIC DAMPENING TO BE PROVIDED TO HVAC SYSTEM
AND PLUMBING WASTE STACKS (VERIFY CAST IRON LOCATIONS WITH OWNER) AS
REQUIRED TO MINIMIZE SOUND TRANSMISSION.
21. PLUMBING ROUGH-IN DIMENSIONS ARE PROVIDED FOR REFERENCE ONLY. ALL
PLUMBING DIMENSIONS ARE TO BE COORDINATED BY THE GENERAL
CONTRACTOR WITH SPECIFIC FIXTURE SELECTIONS AND FINAL CABINET DESIGN.
ALL FLOOR DRAINS CONNECTED TO SANITARY SEWER TO HAVE BACK-FLOW
PREVENTERS INSTALLED.
22. MECHANICAL EQUIPMENT & CONTROL LOCATIONS TO BE VERIFIED WITH OWNER
PRIOR TO INSTALLATION -SEE DRAWINGS FOR PROPOSED LOCATIONS. MAKEUP
AIR TO BE PROVIDED AS PER IBC. AND ANY OTHER APPLICABLE CODES. SUPPLY
AND RETURN REGISTER COVERS TO BE APPROVED BY OWNER - ASSUME FLUSH
WOOD VENTS TO MATCH WOOD FLOOR SPECIES & FINISH FOR BID. WHERE
AFFECTED BY MECHANICAL DUCTS AND EQUIPMENT, CEILING HEIGHTS AND
SOFFIT SIZES AND LOCATIONS TO BE APPROVED BY OWNER PRIOR TO
INSTALLATION OF HVAC DUCTS AND EQUIPMENT
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:53 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
TITLE SHEET, GENERAL
NOTES
A000
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\RevitKELLY RESIDENCE
NOT TO SCALEA000
1 LOCATION MAP
TRUE
N
04/06/23 PERMIT SET
A000
2 FRONT FACADE RENDERING
SHEET INDEX
ARCHITECTURAL
A000 TITLE SHEET, GENERAL NOTES
A100 SITE PLANS
A200 FOUNDATION PLAN
A201 MAIN LEVEL - FLOOR PLAN
A202 SECOND LEVEL - FLOOR PLAN
A203 ROOF PLAN
A300 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
4.6.23
Concept Approval
ONLYSubject to Field Inspection
Inspector Date
2020
MN Bldg
Code
06/23/2023dmathews
S
E
T
BACK1
0
'
-0"SET
BACK10'-0"SETBAC K30'-0"S E TB A C K75'-0 "1 7 '-0 "2"9"0"I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:53 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
SITE PLANS
A100
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit1" = 20'-0"A100
1 EXISTING SITE PLAN
1" = 20'-0"A100
2 PROPOSED SITE PLAN
04/06/23 PERMIT SET
4.6.23
16"W X 8" THICK
CONC AT INTERIOR
STRIP FOOTINGS
8" POURED CONCRETE
WALL W/ 20"W X 8" THICK
POURED CONCRETE
FOOTING. BASE OF
FOOTING SHALL EXTEND
MIN 42" BELOW GRADE
14'-0"19'-6"3'-4"42'-6"24'-2"22'-2"13'-10"2"9'-0"10'-1"20'-0"12'-6"15'-1"3'-4"BEARING WALL
BEARING WALL
BEARING WALL
BEARING WALL
BEARING WALL
BEARING WALL
BEARING WALL
NOTE:
VERIFY W/ STRUCTURAL ENGINEER FOR ALL FRAMING FOUNDATION, & HEADER
INFORMATION.
STRUCTURAL NOTES
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:54 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
FOUNDATION PLAN
A200
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit04/06/23 PERMIT SET
4.6.23
8'-0"Footing Must Be
Extended To Support
Column Load.
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
DWUP
P42
P4
124'-1"11"14'-0"22'-1"18'-11"20'-3 1/2"12'-8"14'-10 1/2"15'-3"12'-4 1/2"4'-4 1/2"14'-3"
2
A301
A3004
A300
3
A300
1
A300 2
OWNER
BEDROOM
BATH
WALK IN
CLOSET
LAUNDRY
BATH
ENTRY
DINING
KITCHEN
FAMILY
ROOM
GARAGE
FRONT
PORCH
CLO
LIN.306060603060304224242424242430423018OVER4032
OVER
4018
4032
OVER
4018
OVER
4032
OVER
4018
2'-4"46'-0"3'-4"19'-6"2'-3"2'-3"6'-4"6'-4"2'-0 1/2"15'-9"2'-6"2'-6"6'-0"5'-6"
2'-0 1/2"9'-0"9'-0"2'-0 1/2"10'-0"14'-0"21'-7"7'-10"3'-0"3'-0"6'-7"4'-0"7'-2"6'-10"6618
OVER 14801480 3018
OVER
3042
12'-0 1/4"2'-1 3/4"2'-2 1/4"3'-4 3/4"2'-2 3/4"2'-4 1/2"6'-10"4'-6 3/4"6'-4"2'-7 1/2"11'-4"4'-4 1/2"1'-0"
4'-0"4'-0"
3'-8 1/2"7"2'-8"2'-9"0"4'-5"3/03/02/82/62/82/8LVL HEADER
LVL HEADER
LVL HEADER30303030LVL HEADERLVL HEADERLVL HEADERLVL HEADERLVL HEADERSLVL HEADERLVL HEADERLVL HEADER
LVL HEADER
VAULTED
VAULTED
ROOF TRUSSES
ROOF TRUSSES
FLOOR TRUSSES
2/8
WATER
HEATER
3/0
5'-11 3/4"6'-0 1/2"4'-4"5'-7 1/2"
7'-1 1/2"7'-1 1/2"9'-9"9'-9"4'-0"10'-0"18' X 9'601860423/0
3618 3618 3618
9/0
10/0
FP
W/D BEAMBEARING WALLBEARING WALL4'-0"CLOSET
COLUMN
LVL HEADER
4'-2"
2'-1
0"
U/C
WINE
COOLER
REF
8'-11 1/2"3'-8 1/4"3'-0"2'-6 1/4"3/0NOTE:
VERIFY W/ STRUCTURAL ENGINEER FOR ALL FRAMING, FOUNDATION, & HEADER
INFORMATION.
SQUARE FOOTAGE
MAIN LEVEL = 1,490 SF
GARAGE = 483 SF
TOTAL = 3,141 SF
NOTE:
1. TYPICAL WINDOW HEAD HEIGHT
MAIN LEVEL: 7'-8"
MAIN LEVEL (WITH TRANSOM): 13'-8"
SECOND LEVEL: 7'-8"
2. WINDOW SIZES ARE FOR REFERENCE ONLY. CONTRACTOR TO ADJUST PER
SELECTED MANUFACTURER
3. ALL DOORS ARE TO BE 6'-8" HIGH, U.N.O.
SECOND LEVEL = 1,168 SF
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:54 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
MAIN LEVEL - FLOOR
PLAN
A201
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit1/4" = 1'-0"A201
1 FLOOR PLAN
04/06/23 PERMIT SET
4.6.23
BWPs
Above
Temper if
within 36"
of floor.
Temper
(2)11-1/4" LVL(2)2x12(2)11-1/4" LVL
(2)11-1/4" LVL(3)2x12(2)2x10PFH PFH
PFH
PFH
PFHPFH(2)9-1/2 LVL(2)11-7/8 LVL(2)9-1/2 LVL
DN
P42
P4
1
2
A301
1
A301
A3004
A300
3
A300
1
A300 2
BEDROOM
BEDROOM
CLOSET
BATH
LOFT /
OFFICE
OPEN TO
MAIN LEVEL
LIN.
VAULTED24'-1"42'-8"18'-9"2'-4 1/2"11'-5"4'-4 3/4"3'-4 1/2"3'-9 3/4"3'-9 3/4"8'-2 3/4"7'-6"17'-3"22'-1"14'-0"
11'-0 1/2"11'-0 1/2"18'-11"47'-10"6'-7"9'-7 1/2"12'-6 1/2"11'-11"3'-3 1/2"4'-1 1/2"10'-0 3/4"4'-4 1/4"
5'-6 3/4"16'-6 1/4"2/8CUSTOM2/8
2/8
ROOF TRUSSES ROOF TRUSSES306030606018OVER304830482/8
BEDROOM3060
3060FURNACE
9'-0"2'-11"3'-3 1/2"
CLOSET
13'-9"20'-0"
3060 3060LVL HEADERLVL HEADERLVL HEADERLVL HEADER
CLOSET
2/8
48302/8
NOTE:
VERIFY W/ STRUCTURAL ENGINEER FOR ALL FRAMING, FOUNDATION, & HEADER
INFORMATION.
SQUARE FOOTAGE
MAIN LEVEL = 1,490 SF
GARAGE = 483 SF
TOTAL = 3,141 SF
NOTE:
1. TYPICAL WINDOW HEAD HEIGHT
MAIN LEVEL: 7'-8"
MAIN LEVEL (WITH TRANSOM): 13'-8"
SECOND LEVEL: 7'-8"
2. WINDOW SIZES ARE FOR REFERENCE ONLY. CONTRACTOR TO ADJUST PER
SELECTED MANUFACTURER
3. ALL DOORS ARE TO BE 6'-8" HIGH, U.N.O.
SECOND LEVEL = 1,168 SF
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:54 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
SECOND LEVEL - FLOOR
PLAN
A202
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit1/4" = 1'-0"A202
1 SECOND FLOOR PLAN
04/06/23 PERMIT SET
4.6.23(2)2x10(3)2x12(3)2x12(3)2x68
-Min. 15" clearance to any
obstruction from center of
W.C., 24" in front(typ).
P42
P4
1
2
A301
1
A301
A3004
A300
3
A300
1
A300 2
8" / 12"
8" / 12"
8" / 12"8" / 12"8" / 12"8" / 12"3" / 12"10" / 12"10" / 12"
6" / 12"
4" / 12"
1'-4"1'-4"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"3" / 12"
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:54 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
ROOF PLAN
A203
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit1/4" = 1'-0"A203
2 ROOF PLAN
04/06/23 PERMIT SET
4.6.23
MAIN LEVEL
100'-0"
SECOND LEVEL
110'-6"
1
A301
T.O. FOOTING
96'-0"
T.O. ROOF
125'-8 1/4"
10"
12"
10"
12"
6"
12"
ASPHALT SHINGLE
SHAKE SIDING
SHAKE SIDING
VERTICAL BOARD AND
BATTEN SIDING
STONE
METAL ROOF
METAL ROOF
/ 990.1
/ 1000.6
1'-4"1'-4"
1'-4"
3"
12"
6"6"
MAIN LEVEL
100'-0"
SECOND LEVEL
110'-6"
2
A301
T.O. FOOTING
96'-0"
T.O. ROOF
125'-8 1/4"
8"
12"
6"
12"
ASPHALT SHINGLE
HORIZONTAL SIDING
STONE
/ 990.1
/ 1000.6
1'-4"
1'-0"
1'-4"
1'-0"
1'-0"
1'-0"
1'-0"
6"6"
MAIN LEVEL
100'-0"
SECOND LEVEL
110'-6"
1
A301
T.O. FOOTING
96'-0"
T.O. ROOF
125'-8 1/4"
T.O. BACK ROOF
124'-9 1/2"8"
12"
8"
12"
8"
12"
8"
12"10"
12"
ASPHALT SHINGLE
HORIZONTAL SIDING
STONE
SHAKE SIDING
/ 990.1
/ 1000.6
4"
12"
1'-4"
1'-0"1'-0"
1'-0"
1'-4"
1'-0"1'-0"
1'-0"
MAIN LEVEL
100'-0"
SECOND LEVEL
110'-6"
2
A301
T.O. FOOTING
96'-0"
T.O. ROOF
125'-8 1/4"
3"
12"
8"
12"
6"
12"
ASPHALT SHINGLE
HORIZONTAL SIDING
STONE
SHAKE SIDING
/ 990.1
/ 1000.6 1'-4"
1'-0"
T.O. FRONT ROOF
123'-3 3/4"
1'-4"
1'-0"
1'-0"
METAL ROOF
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:55 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
EXTERIOR ELEVATIONS
A300
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit1/8" = 1'-0"A300
1 WEST ELEVATION
1/8" = 1'-0"A300
2 NORTH ELEVATION
1/8" = 1'-0"A300
3 EAST ELEVATION
1/8" = 1'-0"A300
4 SOUTH ELEVATION 04/06/23 PERMIT SET
4.6.23
MAIN LEVEL
100'-0"
SECOND LEVEL
110'-6"
1
A301
T.O. FOOTING
96'-0"
T.O. ROOF
125'-8 1/4"8'-11 1/2"9'-0"8'-0 1/2"1'-4"
1'-0"
1'-0"1'-0"
1'-0"
1'-0"
MAIN LEVEL
100'-0"
SECOND LEVEL
110'-6"
2
A301
T.O. FOOTING
96'-0"
T.O. BACK ROOF
124'-9 1/2"8'-11 1/2"/ 990.1
/ 1000.6
1'-0"
1'-0"
1'-0"
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,
OR REPORT WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM A DULY
LICENSED ARCHITECT UNDER THE LAWS OF THE
STATE OF MINNESOTA.
JENNIFER KAEDING, AIA
51456
DATEREGISTRATION #
PROJECT:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT INFORMATION:
SHEET NAME:
SHEET NUMBER:
ISSUE RECORD:
235 W. MAIN STREET, SUITE 201
WACONIA, MN 55387
952.451.9763
N
4/6/2023 3:58:56 PMKELLYRESIDENCE
KSTREY
JKAEDING
04/06/23
BUILDING SECTIONS
A301
KELLY RESIDENCE
17170 JUDICIAL ROAD,
LAKEVILLE, MN 55044
N:\! Projects\Kelly Residence\Revit1/4" = 1'-0"A301
2 NORTH-SOUTH SECTION
1/4" = 1'-0"A301
1 EAST-WEST SECTION
04/06/23 PERMIT SET
4.6.23
4/26/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
WB-1---
4/26/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
WB-2---
·
·
·
·
·
4/26/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESTML TML TML
1/8" = 1'-0"04/26/2023
FR-02---
4/26/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESTML TML TML
1/8" = 1'-0"04/26/2023
FR-03---
4/26/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESTML TML TML
1/8" = 1'-0"04/26/2023
FR-03.1---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
WB-1---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
WB-2---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:FRAMING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
FR-1---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:FRAMING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
FR-2---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:FRAMING PLAN17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESAR MMM TML
1/8" = 1'-0"04/26/2023
FR-3---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESTML TML TML
1/8" = 1'-0"04/26/2023
FR-02---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESTML TML TML
1/8" = 1'-0"04/26/2023
FR-03---
5/22/2023
I hereby certify that this plan, specification or report
was prepared by me or under my direct supervision
and that I am a duly Licensed Professional Engineer
under the laws of the State of Minnesota.
Signed:___________________________________
Print Name:_______________________________
Date:____________License Number:___________54690
Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS05/09/2023REVISED WALL BRACINGAR------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC.
19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070
PH: 281.351.0048 FAX: 281.351.0148
SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE:
DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17170 JUDICIAL ROAD, LAKEVILLE, MN 55044RONGITSCH HOMESTML TML TML
1/8" = 1'-0"04/26/2023
FR-03.1---
Top Plate
Considerations
Top Plate
Compression values below by species (Fc perp):
-PSL Column thru top plate2500 psi
-SYP MSR 2400805 psi
-SPF Studs thru top plate725 psi -DFL (N)625 psi
-DFL (US)625 psi -SYP565 psi
-SPF425 psi
-Hem-Fir (US)405 psi
-Hem-Fir (N)370 psi
E
A1
PB
A
C3
C
B
C2(5)PB1(8)D(2)C1E1 (5)B12'2'2'2'1'11"4
2'2'2'2'2'2'2'2'<<------8/12 VAULT----->>
<<------8/12 VAULT----->>
<<------8/12 VAULT----->>
<<------8/12 VAULT
<<------8/12 VAULT (2) 11 7/8" FLUSH BEAM (supplied by ABC)ROOF PLAN NOTES:
1. TRUSS IDENTIFICATION LABEL LOCATED ONBOTTOM SIDE OF BOTTOM CHORD
2. ALL DIMENSIONS ARE IN FEET- INCHES-16THS
3. END OF TRUSS WITH "X" TICK MARK ON THE LAYOUTCORRESPONDS WITH LEFT END ON TRUSS DRAWING.
4. DO NOT MODIFY, CUT, OR REPAIR ANY PORTION OF THETRUSSES WITHOUT APPROVAL FROM ABC TRUSS. WARRANTYWILL BE VOIDED WITHOUT OFFICIAL DOCUMENTATION.
5. SEE INDIVIDUAL TRUSS CALC FOR MULTI-PLY GIRDERCONNECTION AND PERMANENT BRACING INFORMATION
6. SEE HANGER INSTALLATION GUIDE OR CATALOG FORMORE DETAIL ON HANGER ATTACHMENT.
7. TEMPORARY BRACING INFORMATION IS SHOWN ON THEBCSI-B1 SUMMARY SHEET LOCATED IN THE JOB PACKET.
8. THE INTENT OF THIS DOCUMENT IS TO SHOW TRUSSPLACEMENT ONLY. THE CONTRACTOR IS RESPONSIBLEFOR VERIFYING ALL DIMENSIONS AND WALL HEIGHTSWITH THE BLUEPRINT PRIOR TO SETTING THE TRUSSES.
9. BEARINGS DESIGNED FOR A FcPerp VALUE OF 425 FOR ALL BEARINGS.(UNLESS NOTED OTHERWISE BY A FcPerp ### NOTE)"TOP PLATE OF BEARING WALL DESIGN AND MATERIAL BY OTHERS."
10. SET ALL VALLEY TRUSSES AFTER MAIN ROOF HAS BEEN SHEATHED.ADJUSTMENT OF SPACING MAY BE REQUIRED.
MONO TRUSSES NOTCHED TO BEAR ON LEDGER(2) 9 1/2" FLUSH BEAM (supplied by ABC) BEARING WALLTOP PLATE FCPERP 625 FOR B & B1 TRUSSES(2) 11-7/8" FLUSH BEAM (supplied by ABC)
TOP OF PORCH BEAM UP 1-1-4 FROM TOP OF MAIN FLOOR PLATE HEIGHT
PAGE NO:
1 OF 1
JOB NO:
T232111 Name: Kelly CabinCustomer: Lampert Yards /Av Address: 17170 JUDICIAL RDSalesman: CMDesigner: Derek Widiker
F3
L1
K
H
L9
F
G
L6
L3
L
J2 J
L8
LA
G
L5
L2
K1
L7
F2
L4
2 PLY2 PLY2 PLY
2 PLY
(4)F1(6)J1
(2)F4(3)G11'11"42'2'2'2'2'2'1'11"12
2'0"42'2'1'9"2
2'2"142'2'1'1"152'2'2'2'ROOF PLAN NOTES:
1. TRUSS IDENTIFICATION LABEL LOCATED ONBOTTOM SIDE OF BOTTOM CHORD
2. ALL DIMENSIONS ARE IN FEET- INCHES-16THS
3. END OF TRUSS WITH "X" TICK MARK ON THE LAYOUTCORRESPONDS WITH LEFT END ON TRUSS DRAWING.
4. DO NOT MODIFY, CUT, OR REPAIR ANY PORTION OF THETRUSSES WITHOUT APPROVAL FROM ABC TRUSS. WARRANTYWILL BE VOIDED WITHOUT OFFICIAL DOCUMENTATION.
5. SEE INDIVIDUAL TRUSS CALC FOR MULTI-PLY GIRDERCONNECTION AND PERMANENT BRACING INFORMATION
6. SEE HANGER INSTALLATION GUIDE OR CATALOG FOR
MORE DETAIL ON HANGER ATTACHMENT.
7. TEMPORARY BRACING INFORMATION IS SHOWN ON THEBCSI-B1 SUMMARY SHEET LOCATED IN THE JOB PACKET.
8. THE INTENT OF THIS DOCUMENT IS TO SHOW TRUSSPLACEMENT ONLY. THE CONTRACTOR IS RESPONSIBLEFOR VERIFYING ALL DIMENSIONS AND WALL HEIGHTSWITH THE BLUEPRINT PRIOR TO SETTING THE TRUSSES.
9. BEARINGS DESIGNED FOR A FcPerp VALUE OF 425 FOR ALL BEARINGS.(UNLESS NOTED OTHERWISE BY A FcPerp ### NOTE)"TOP PLATE OF BEARING WALL DESIGN AND MATERIAL BY OTHERS."
10. SET ALL VALLEY TRUSSES AFTER MAIN ROOF HAS BEEN SHEATHED.ADJUSTMENT OF SPACING MAY BE REQUIRED.
6-5-3 PLATE HEIGHT
HANDFRAME AREA(design & material by others)(2) 9 1/2" FLSH BEAM (supplied by ABC) *** LIGHT BLUE WALLS ARE 3-6-0 ***KNEE WALL ON TOP OF FLOOR DECKING
(2) 9 1/2" DROPPED BEAM (supplied by ABC)
PAGE NO:
1 OF 1
JOB NO:
T232111 Name: Kelly CabinCustomer: Lampert Yards /Av Address: 17170 JUDICIAL RDSalesman: CMDesigner: Derek Widiker
F3
L1
K
H
L9
F
G
L6
L3
L
J2 J
L8
LA
G
L5
L2
K1
L7
F2
L4
2 PLY2 PLY2 PLY
2 PLY
(4)F1(6)J1
(2)F4(3)G11'11"42'2'2'2'2'2'1'11"12
2'0"42'2'1'9"2
2'2"142'2'1'1"152'2'2'2'ROOF PLAN NOTES:
1. TRUSS IDENTIFICATION LABEL LOCATED ONBOTTOM SIDE OF BOTTOM CHORD
2. ALL DIMENSIONS ARE IN FEET- INCHES-16THS
3. END OF TRUSS WITH "X" TICK MARK ON THE LAYOUTCORRESPONDS WITH LEFT END ON TRUSS DRAWING.
4. DO NOT MODIFY, CUT, OR REPAIR ANY PORTION OF THETRUSSES WITHOUT APPROVAL FROM ABC TRUSS. WARRANTYWILL BE VOIDED WITHOUT OFFICIAL DOCUMENTATION.
5. SEE INDIVIDUAL TRUSS CALC FOR MULTI-PLY GIRDERCONNECTION AND PERMANENT BRACING INFORMATION
6. SEE HANGER INSTALLATION GUIDE OR CATALOG FORMORE DETAIL ON HANGER ATTACHMENT.
7. TEMPORARY BRACING INFORMATION IS SHOWN ON THEBCSI-B1 SUMMARY SHEET LOCATED IN THE JOB PACKET.
8. THE INTENT OF THIS DOCUMENT IS TO SHOW TRUSSPLACEMENT ONLY. THE CONTRACTOR IS RESPONSIBLEFOR VERIFYING ALL DIMENSIONS AND WALL HEIGHTSWITH THE BLUEPRINT PRIOR TO SETTING THE TRUSSES.
9. BEARINGS DESIGNED FOR A FcPerp VALUE OF 425 FOR ALL BEARINGS.(UNLESS NOTED OTHERWISE BY A FcPerp ### NOTE)"TOP PLATE OF BEARING WALL DESIGN AND MATERIAL BY OTHERS."
10. SET ALL VALLEY TRUSSES AFTER MAIN ROOF HAS BEEN SHEATHED.ADJUSTMENT OF SPACING MAY BE REQUIRED.
6-5-3 PLATE HEIGHT
HANDFRAME AREA(design & material by others)(2) 9 1/2" FLSH BEAM (supplied by ABC) *** LIGHT BLUE WALLS ARE 3-6-0 ***KNEE WALL ON TOP OF FLOOR DECKING
(2) 9 1/2" DROPPED BEAM (supplied by ABC)
MM(4)M1
PAGE NO:
1 OF 1
JOB NO:
T232111 Name: Kelly CabinCustomer: Lampert Yards /Av Address: 17170 JUDICIAL RDSalesman: CMDesigner: Derek Widiker
2x6 Strongback bracing required every 10ft o.c.Strongbacks to be secured to vertical with (3) 16d nailsStrongback lumber should be as continuous as possible per BCSI-B7 and finaldecision on required length is per Building DesignerInstall strongbacks prior to sheathing; See job packet for additional details
2G
2C
2F
2L
2A
2O
2K
2H
2E
(12)2B(2)2M(4)2J(2)2D(10)2N1'5"7
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'6"11
1'7"11
1'7"3
1'7"3
1'7"3
1'7"3
1'7"9
1'6"13
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
FLUSH BEAM(supplied by others)BEARING WALLBEARING WALLBEARING WALLBEARING WALLBEARING WALL **CAUTION** APPROXIMATEPLUMBING LOCATIONS
MAIN FLOOR PLAN NOTES:
1. 18" 4X2 FLOOR TRUSSES
2. 1/2" SHEATHING DEDUCT
3. TRUSS IDENTIFICATION LABEL LOCATED ON ENDOF TRUSS.
4. LEFT END OF TRUSS IS PAINTED. THE (X) TICK MARK ONLAYOUT INDICATES LEFT END OF TRUSS AS SHOWN ONLEFT SIDE OF TRUSS DRAWING.
5. ALL DIMENSIONS ARE IN FEET - INCHES - 16THS
6. HOLD RIBBON FLUSH WITH TOP OF TRUSS. NOTCH ISMADE LARGER FOR VARYING LUMBER THICKNESS.
7. CHECK PLUMBING AND MECHANICAL LOCATIONS PRIORTO SHEATHING FLOOR TRUSSES. TOILET SYMBOL DOESNOT REPRESENT EXACT LOCATION.
8. DO NOT MODIFY, CUT, OR REPAIR ANY PORTION OF THE
TRUSSES WITHOUT WRITTEN APPROVAL FROM ABC TRUSS.WARRANTY WILL BE VOIDED WITHOUT OFFICIALDOCUMENTATION.
9. THE INTENT OF THIS DOCUMENT IS TO SHOW TRUSSPLACEMENT ONLY. THE CONTRACTOR WILL BERESPONSIBLE FOR VERIFING ALL DIMENSIONS AND WALLHEIGHTS WITH THE BLUEPRINT PRIOR TO SETTING TRUSSES.
10. STRONGBACK BRACING IS REQUIRED 10FT O.C. PER BCSI/B7.5FT O.C. IS RECOMMENDED FOR HIGHER PERFORMING SYSTEM.
(2) 9 1/2" FLUSH BEAM (supplied by ABC)HGUS48(2) 111-7/8" FLUSH BEAM (supplied by ABC)
PAGE NO:
1 OF 1
JOB NO:
T232111F Name: Kelly CabinCustomer: Lampert Yards /Av Address: 17170 JUDICIAL RDSalesman: CMDesigner: Derek Widiker
2x6 Strongback bracing required every 10ft o.c.Strongbacks to be secured to vertical with (3) 16d nailsStrongback lumber should be as continuous as possible per BCSI-B7 and finaldecision on required length is per Building DesignerInstall strongbacks prior to sheathing; See job packet for additional details
2G
2C
2F
2L
2A
2O
2K
2H
2E
(12)2B(2)2M(4)2J(2)2D(10)2N1'5"7
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'6"11
1'7"11
1'7"3
1'7"3
1'7"3
1'7"3
1'7"9
1'6"13
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
1'7"3
FLUSH BEAM(supplied by others)BEARING WALLBEARING WALLBEARING WALLBEARING WALLBEARING WALL **CAUTION** APPROXIMATEPLUMBING LOCATIONS
MAIN FLOOR PLAN NOTES:
1. 18" 4X2 FLOOR TRUSSES
2. 1/2" SHEATHING DEDUCT
3. TRUSS IDENTIFICATION LABEL LOCATED ON ENDOF TRUSS.
4. LEFT END OF TRUSS IS PAINTED. THE (X) TICK MARK ONLAYOUT INDICATES LEFT END OF TRUSS AS SHOWN ONLEFT SIDE OF TRUSS DRAWING.
5. ALL DIMENSIONS ARE IN FEET - INCHES - 16THS
6. HOLD RIBBON FLUSH WITH TOP OF TRUSS. NOTCH ISMADE LARGER FOR VARYING LUMBER THICKNESS.
7. CHECK PLUMBING AND MECHANICAL LOCATIONS PRIORTO SHEATHING FLOOR TRUSSES. TOILET SYMBOL DOESNOT REPRESENT EXACT LOCATION.
8. DO NOT MODIFY, CUT, OR REPAIR ANY PORTION OF THE
TRUSSES WITHOUT WRITTEN APPROVAL FROM ABC TRUSS.WARRANTY WILL BE VOIDED WITHOUT OFFICIALDOCUMENTATION.
9. THE INTENT OF THIS DOCUMENT IS TO SHOW TRUSSPLACEMENT ONLY. THE CONTRACTOR WILL BERESPONSIBLE FOR VERIFING ALL DIMENSIONS AND WALLHEIGHTS WITH THE BLUEPRINT PRIOR TO SETTING TRUSSES.
10. STRONGBACK BRACING IS REQUIRED 10FT O.C. PER BCSI/B7.5FT O.C. IS RECOMMENDED FOR HIGHER PERFORMING SYSTEM.
(2) 9 1/2" FLUSH BEAM (supplied by ABC)HGUS48(2) 111-7/8" FLUSH BEAM (supplied by ABC)
PAGE NO:
1 OF 1
JOB NO:
T232111F Name: Kelly CabinCustomer: Lampert Yards /Av Address: 17170 JUDICIAL RDSalesman: CMDesigner: Derek Widiker
Site address
Contractor
1
Total/
continuous
60/40
70/40
80/40
90/45
100/50
110/55
120/60
130/65
140/70
150/75
Equation 11-1
Directions - Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1.
The table and equation are below
Total required ventilation
Continuous ventilation
Section A
Total ventilation – The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate
average, for each one‐hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy
recovery ventilators (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of
exhaust or out outdoor air intake, or both, for defrost or other equipment cycling.
Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided,
on a continuous rate average for each one‐hour period. The portion of the mechanical ventilation system intended to be
continuous may have automatic cycling controls providing the average flow rate for each hour is met.
(0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm)
Date
Completed
By
Ventilation Quantity
(Determine quantity by using Table R403.5.2 or Equation 11‐1)
Square feet (Conditioned area including
Basement – finished or unfinished)
Number of bedrooms
Table R403.5.2
Total and Continuous Ventilation Rates (in cfm)
Number of Bedrooms
2 3 4 5 6
Total/
continuous
1000‐1500 75/40 90/45 105/53 120/60 135/68
Conditioned space (in
sq. ft.)
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
145/73
2001‐2500 95/48 110/55 125/63 140/70 155/78
1501‐2000 85/43 100/50 115/58 130/65
165/83
3001‐3500 115/58 130/65 145/73 160/80 175/88
2501‐3000 105/53 120/60 135/68 150/75
185/93
4001‐4500 135/68 150/75 165/83 180/90 195/98
3501‐4000 125/63 140/70 155/78 170/85
205/103
5001‐5500 155/78 170/85 185/93 200/100 215/108
4501‐5000 145/73 160/80 175/88 190/95
225/1135501‐6000 165/83 180/90 195/98 210/105
Continuous
Ventilation Method
(Choose either balanced or exhaust only)
Low cfm:High cfm:Continuous fan rating in cfm (capacity must not exceed
continuous ventilation rating by more than 100%)
Ventilation Fan Schedule
Description Location Intermittent
Section C
Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous
or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating
and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not
exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour.
Section D
Directions - Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and inspectors to verify design and
installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans
are used for building ventilation, describe the operation and location of any controls, indicators and legends. If an ERV or HRV is to be installed, describe how
it will be installed. If it will be connected and interfaced with the air handling equipment, please describe such connections as detailed in the manufactures’
installation instructions. If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper
operation, such interconnection shall be made and described.
Section B
Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery
Ventilator) – cfm of unit in low must not exceed continuous
ventilation rating by more than 100%.
Exhaust only
Continuous fan rating in cfm
Directions - Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV’s.
Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous ventilation rate and
less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.)
Automatic controls may allow the use of a larger fan that is operated a percentage of each hour.
Ventilation Controls
(Describe operation and control of the continuous and intermittent ventilation)
One or multiple power
vent or direct vent ap‐ pliances
or no combus‐ tion appliances
Column A
One or multiple fan‐
assisted appliances and power
vent or direct vent appliances
Column B
One atmospherically vent
gas or oil appliance or one solid
fuel appliance
Column C
Multiple atmospherical‐
ly vented gas or oil appliances
or solid fuel appliances
Column D
1.
a) pressure factor
(cfm/sf)
0.15 0.09 0.06 0.03
b) conditioned floor area (sf) (including
unfinished basements)
Estimated House Infiltration (cfm): [1a
x 1b]
2. Exhaust Capacity
a) continuous exhaust‐only ventilation system
(cfm); (not applicable to ba‐ lanced ventilation
systems such as HRV)
b) clothes dryer (cfm)135 135 135 135
c) 80% of largest exhaust rating (cfm);
Kitchen hood typically
(not applicable if recirculating system or if
powered makeup air is electrically interlocked
and match to exhaust)d) 80% of next largest exhaust rating
(cfm); bath fan typically
(not applicable if recirculating system or if
powered makeup air is electrically interlocked
and matched to exhaust)
Not
Applicable
Total Exhaust Capacity (cfm);
[2a + 2b +2c + 2d]
3. Makeup Air Quantity (cfm)
a) total exhaust capacity (from above)
b) estimated house infiltration (from
above)
Makeup Air Quantity (cfm);
[3a – 3b]
(if value is negative, no makeup air is needed)
4. For makeup Air Opening Sizing, refer
to Table 501.4.2
C. Use this column if there is one atmospherically vented (other than fan‐assisted) gas or oil appliance per venting system or one solid fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid
fule appliances.
Table 501.4.1
PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS
(Additional combustion air will be required for combustion appliances, see KAIR method for calculations)
Directions ‐ In order to determine the makeup air, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if
atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air
will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to
the last line of section D.
A. Use this column if there are other than fan‐assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent
appliances may be used.)
B. Use this column if there is one fan‐assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.)
One or multiple power
vent, direct vent ap‐
pliances, or no combus‐
tion appliances
Column A
Multiple atmospherically
vented gas or oil ap‐
pliances or solid fuel
appliances
Column D
Duct di‐
ameter
1 – 36 1 – 9 3
37 – 66 10 – 17 4
67 – 109 18 – 28 5
110 ‐ 163 29 – 42 6
164 – 232 43 – 61 7
233 – 317 62 – 83 8
318 – 419 84 – 110 9
420 – 539 111 – 142 10
540 – 679 143 – 179 11
>679 >179 NA
Notes:
A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90‐ degree elbow to
determine the remaining length of straight duct allowable.
B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted.
C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
D. Powered makeup air shall be electrically interlocked with the largest exhaust system.
Explanation ‐ If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented
or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E‐1 (see below). Please enter size and type. Combustion
air vent supplies must communicate with the appliance or appliances that require the combustion air.
Section F calculations follow on the next 2 pages.
One or multiple fan‐
assisted appliances and
power vent or direct vent
appliances Column B
One atmospherically vented
gas or oil ap‐
pliance or one solid fuel
appliance
Column CPassive opening 1 – 22 1 – 15
Passive opening 23 – 41 16 – 28
Passive opening 42 – 66 29 – 46
Passive opening 67 – 100 47 – 69
Passive opening 101 – 143 70 – 99
231 – 290
Passive opening 144 – 195 100 – 135
Passive opening
w/motorized damper
196 – 258 136 – 179
Passive (see IFGC Appendix E, Worksheet E‐1)Size and type
Other, describe:
Table 501.4.2
Makeup Air Opening Sizing Table for New and Existing Dwelling Units
Powered makeup air >419 >290
Combustion air
Not required per mechanical code (No atmospheric or power vented appliances)
Passive opening
w/motorized damper
259 – 332 180 – 230
Passive opening
w/motorized damper
333 – 419
IFGC Appendix E, Worksheet E‐1
Residential Combustion Air Calculation Method
(for Furnace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combustion appliance information.
Furnace/Boiler:
Draft Hood Fan Assisted Direct Vent Input: Btu/hr or Power Vent
Water Heater:
Draft Hood Fan Assisted Direct Vent Input: Btu/hr or Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3
L x W x H L W H
Step 3: Determine Air Changes per Hour (ACH)1
Default ACH values have been incorporated into Table E‐1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use
method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air. (DO NOT COUNT DIRECT VENT APPLIANCES)
4a. Standard Method
Total Btu/hr input of all combustion appliances Input: Btu/hr
Use Standard Method column in Table E‐1 to find Total Required TRV: ft3
Volume (TRV)
If CAS Volume (from Step 2) i s gr ea t er th an TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) i s less than TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES)
Total Btu/hr input of all fan-assisted and power vent appliances Input: Btu/hr
Use Fan‐Assisted Appliances column in Table E‐1 to find RVFA: ft3
Required Volume Fan Assisted (RVFA)
Total Btu/hr input of all Natural draft appliances Input: Btu/hr
Use Natural draft Appliances column in Table E‐1 to find RVNFA: ft3
Required Volume Natural draft appliances (RVNDA)
Total Required Volume (TRV) = RVFA + RVNDA TRV = + = TRV ft3
Step 5: Calculate the ratio of available interior volume to the total required volume.
Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b)
Ratio = / =
Step 6: Calculate Reduction Factor (RF).
RF = 1 mi nus Ratio RF = 1 ‐ =
Step 7: Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr
(EXCEPT DIRECT VENT)
Combustion Air Opening Area (CAOA):
Total Btu/hr d i vid ed by 3000 Btu/hr per in2 CAOA = / 3000 Btu/hr per in2 = in2
Step 8: Calculate Minimum CAOA.
Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2
Step 9: Calculate Combustion Air Opening Diameter (CAOD)
CAOD = 1.13 m ultiplied by the sq uare root of Minimum CAOA CAOD = 1.13 √ Minimum CAOA = in. diameter go up one inch in size
if using flex duct
1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section
G304.
Directions ‐ The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air
Infiltration Rate Method. For new construction, 4b of step 4 is required to be filled out.
1994 to present Pre‐1994 1994 to present Pre‐1994
5,000 250 375 188 525 263
10,000 500 750 375 1,050 525
15,000 750 1,125 563 1,575 788
20,000 1,000 1,500 750 2,100 1,050
25,000 1,250 1,875 938 2,625 1,313
30,000 1,500 2,250 1,125 3,150 1,575
35,000 1,750 2,625 1,313 3,675 1,838
40,000 2,000 3,000 1,500 4,200 2,100
45,000 2,250 3,375 1,688 4,725 2,363
50,000 2,500 3,750 1,675 5,250 2,625
55,000 2,750 4,125 2,063 5,775 2,888
60,000 3,000 4,500 2,250 6,300 3,150
65,000 3,250 4,875 2,438 6,825 3,413
70,000 3,500 5,250 2,625 7,350 3,675
75,000 3,750 5,625 2,813 7,875 3,938
80,000 4,000 6,000 3,000 8,400 4,200
85,000 4,250 6,375 3,188 8,925 4,463
90,000 4,500 6,750 3,375 9,450 4,725
95,000 4,750 7,125 3,563 9,975 4,988
100,000 5,000 7,500 3,750 10,500 5,250
105,000 5,250 7,875 3,938 11,025 5,513
110,000 5,500 8,250 4,125 11,550 5,775
115,000 5,750 8.625 4,313 12,075 6,038
120,000 6,000 9,000 4,500 12,600 6,300
125,000 6,250 9,375 4,688 13,125 6,563
130,000 6,500 9,750 4,875 13,650 6,825
135,000 6,750 10,125 5,063 14,175 7,088
140,000 7,000 10,500 5,250 14,700 7,350
145,000 7,250 10,875 5,438 15,225 7,613
150,000 7,500 11,250 5,625 15,750 7,875
155,000 7,750 11,625 5,813 16,275 8,138
160,000 8,000 12,000 6,000 16,800 8,400
165,000 8,250 12,375 6,188 17,325 8,663
170,000 8,500 12,750 6,375 17,850 8,925
175,000 8,750 13,125 6,563 18,375 9,188
180,000 9,000 13,500 6,750 18,900 9,450
185,000 9,250 13,875 6,938 19,425 9,713
190,000 9,500 14,250 7,125 19,950 9,975
195,000 9,750 14,625 7,313 20,475 10,238
200,000 10,000 15,000 7,500 21,000 10,500
205,000 10,250 15,375 7,688 21,525 10,783
210,000 10,500 15,750 7,875 22,050 11,025
215,000 10,750 16,125 8,063 22,575 11,288
220,000 11,000 16,500 8,250 23,100 11,550
225,000 11,250 16,875 8,438 23,625 11,813
230,000 11,500 17,250 8,625 24,150 12,075
1. The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is
0.20 ACH.
2. This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH.
IFGC Appendix E, Table E‐1
Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance)
Input Rating
(Btu/hr)
Standard Method Known Air Infiltration Rate (KAIR) Method (cu ft)
Fan Assisted or Power Vent Natural Draft
17170 Judicial Road Lakeville
HVAC Load Calculations
for
Rongitsch Constructions
Prepared By:
Lucas Breitbach
Air Mechanical
16411 Aberdeen St Ne
Ham Lake, MN 55304
763-634-8030
Tuesday, June 20, 2023
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air Mechanical Inc.17170 Judicial Road Lakeville
Ham Lake, MN 55304 Page 2
Project Report
General Project Information
Project Title:17170 Judicial Road Lakeville
Designed By:Lucas Breitbach
Project Date:Tuesday, June 13, 2023
Client Name:Rongitsch Constructions
Company Name:Air Mechanical
Company Representative:Lucas Breitbach
Company Address:16411 Aberdeen St Ne
Company City:Ham Lake, MN 55304
Company Phone:763-634-8030
Design Data
Reference City:Minneapolis/St. Paul AP, Minnesota
Building Orientation:Front door faces North
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-15 -11.42 n/a 30%72 27.91
Summer:88 71 44%50%75 24
Check Figures
Total Building Supply CFM:1,267 CFM Per Square ft.:0.477
Square ft. of Room Area:2,658 Square ft. Per Ton:1,012
Volume (ft³):22,754
Building Loads
Total Heating Required Including Ventilation Air:67,139 Btuh 67.139 MBH
Total Sensible Gain:27,868 Btuh 88 %
Total Latent Gain:3,656 Btuh 12 %
Total Cooling Required Including Ventilation Air:31,524 Btuh 2.63 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
\\ami-fp\users$ ...\17170 Judicial Road Lakeville.r10 Tuesday, June 20, 2023, 10:13 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air Mechanical Inc.17170 Judicial Road Lakeville
Ham Lake, MN 55304 Page 3
Load Preview Report
Scope
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 2.63 1,012 2,658 27,868 3,656 31,524 67,139 826 1,267 1,267
System 1 2.63 1,012 2,658 27,868 3,656 31,524 67,139 826 1,267 1,267 12x18
Ventilation 749 2,094 2,843 5,014 135 135 135
Supply Duct Latent 245 245
Return Duct 65 40 104 433
Humidification 4,679
Zone 1 2,658 27,054 1,278 28,332 57,013 826 1,267 1,267 12x18
1-Main Level 1,490 18,224 1,278 19,502 35,077 508 854 854 8--7
2-Upper Level 1,168 8,830 0 8,830 21,936 318 414 414 4--7
\\ami-fp\users$ ...\17170 Judicial Road Lakeville.r10 Tuesday, June 20, 2023, 10:13 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air Mechanical Inc.17170 Judicial Road Lakeville
Ham Lake, MN 55304 Page 4
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
LOW EE: Glazing-Standard Double Pain Window, U-
value 0.3, SHGC 0.35
405 10,570 0 11,580 11,580
11K: Door-Metal - Fiberglass Core With Storm, U-value
0.36
36 1,127 0 311 311
12B-0sw: Wall-Frame, R-11 insulation in 2 x 4 stud
cavity, no board insulation, siding finish, wood studs,
U-value 0.097
2651 22,372 0 5,682 5,682
16BR-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Unvented Attic with Radiant Barrier, Any
Roofing Material, Any Roof Color, R-50 insulation, U-
value 0.02
1490 2,592 0 1,430 1,430
22C-5pl-t: Floor-Slab on grade, Horizontal board
insulation extends 4' under slab, tile covering, R-5
insulation, passive, light dry soil, U-value 0.98
164 13,983 0 0 0
20P-19-c: Floor-Over open crawl space or garage,
Passive, R-19 blanket insulation, carpet covering, U-
value 0.05
528 2,297 0 211 211
Subtotals for structure:52,941 0 19,214 19,214
People:5 1,000 1,150 2,150
Equipment:278 4,116 4,394
Lighting:500 1,705 1,705
Ductwork:4,505 284 933 1,218
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM: 135, Summer CFM: 135 5,014 2,094 749 2,843
Humidification (Winter) 12.76 gal/day :4,679 0 0 0
Total Building Load Totals:67,139 3,656 27,868 31,524
Check Figures
Total Building Supply CFM:1,267 CFM Per Square ft.:0.477
Square ft. of Room Area:2,658 Square ft. Per Ton:1,012
Volume (ft³):22,754
Building Loads
Total Heating Required Including Ventilation Air:67,139 Btuh 67.139 MBH
Total Sensible Gain:27,868 Btuh 88 %
Total Latent Gain:3,656 Btuh 12 %
Total Cooling Required Including Ventilation Air:31,524 Btuh 2.63 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
\\ami-fp\users$ ...\17170 Judicial Road Lakeville.r10 Tuesday, June 20, 2023, 10:13 AM
Builders Association of Minnesota version 101014
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. -COPY OF THIS DOCCUMENT WILL BE POSTED ON THE PLENTUM OF FURNACE
Date Certificate Posted
6/13/2023
Mailing Address of the Dwelling or Dwelling Unit:City:
17170 Judical Road Lakeville
Name of Residential Contractor: MN License Number
THERMAL ENVELOPE RADON CONTROL SYSTEM
Insulation Location
Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
IF fan is required; Attic
Other Please Describe Here
Below Entire Slab X
Foundation Wall X
Perimeter of Slab on Grade R-15 X
Rim Joist (1st Floor)X
Rim Joist (2nd Floor+)X
Wall R-21 X
Ceiling, flat X
Ceiling, vaulted R-49 X
Bay Windows or cantilevered areas X
Floors over unconditioned area X
Describe other insulated areas
Building envelope air tightness:Duct system air tightness:
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.32 X Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):0.34 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water
Heater Cooling System X Not required per mech. code
Fuel Type Natural Gas NA R-410 Passive
Manufacturer Bryant NA Bryant Powered
Model 986TA42080V17 NA BA13NA036 Interlocked with exhaust device.
Describe:
Rating or Size Input in
BTUS:80000 Capacity in
Gallons:
Output
in Tons:3 Other, describe:
Efficiency AFUE or
HSPF%96%SEER
/EER 13 Location of duct or system:
Residential Load
Calculation
Heating Loss Heating Gain Cooling Load ERV/HRV in Mechanical Room
67139 27868 31524 Cfm's
" round duct OR MECHANICAL VENTILATION SYSTEM " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace): Combustion Air Select a Type
Not required per mech. code
Select Type X Passive
X Heat Recover Ventilator (HRV) Capacity in cfms:Low: 68 High:135 Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfms:Low: High: Location of duct or system:
Balanced Ventilation capacity in cfms:Mechanical Room
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfms:68 5" " round duct OR
Total ventilation (intermittent + continuous) rate in cfms:135 " metal duct
NEW RESIDENTIAL CON STRUCT ION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications .
A National Pollutant Discharge Elimination System (NPDES) Cons truction Stormwater Permit is
required for "Construction activity that results in land disturbance of equal to or greater than one (1)
acre or if a project is part of a common plan of development that will ultimately disturb greater than
one (1) acre," (NPDES Permit, Section 1.2 ).
Project Site Address: / 1 { 7 0 :S vd 1
1 C ,· a. ( 'f2 o e,..cJ,
Company Name: /2_ OtA~ir s C "-(!. OV". 9 f rv C 1-( o h / h <. ,
·Primary Company Contact: _N'.__~_+_~_&.1._""-::...._---1.:Tl:::o:::.._:""':..J1.J.l•.J.:t~s~c.=-'----------------
shou1d • site be deemed noncompllant, this individual will be notified
Phone#: 0 /Z -(,,(8 -8 ( 8 { Email: h()..-1-e @ V"O i r Sc'"'. Ca"""'-
If you are not covered under a NPDES Construction Stormwater Permit administered by the
Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be
approved as part of the residential building permit application.
"Permittees must ensure a trained person will inspect the entire construction site at least once every
seven (7) days during active construction and within 24 hours after a rainfall event greater than ½
inch in 24 hours," (NPDES Permit, Section 11.2).
The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may
issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to
bring the site into compliance with the NPDES Construction Stormwater Permit (_MN R 100001) or
erosion and sediment control plan.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name: /0 a.-t"'·-lt \I\ fZo(/\ / + ,c fr._
Phone# (24 hr Contact): 6/Z 6/B 8(~ 1
Company: f2-oll\1 f +~h Gbi-t5W<1c. tt°"'
Email: ha.. +-e co} V-00:J {+-SC i... · C tJ v-"
Entity that Provided Training: _________ _ Certification Expiration Date: ___ _
NO!E: .Prior to ,any land-disturbing activity, all erosion and sediment controls must be installed
I understand the above in ation to be accurate and I have read , understood, and accepted all terms and
conditions of the NPDE mit (MN R 100001 ).
Signature: ---t-;.}!E/_:-_::-~_:-~_:-~_ -_ -_ -_ -_-:__ _____ Date: /3 0 / Z?
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
Version: 10/30/2019