HomeMy WebLinkAbout18040 Hinckley Avenue - Survey45.00
57.007.00
12.5013.00
HIN
CK
L
EY
AV
ENU
E
2Drainage and Utility EasementWETWETBuildin
g
S
e
t
b
a
c
k
18040 Hinckley Ave
IIIIIII>>>>>>>>>>>>>>>>>>>>>>>>>IIIIIIIIIPROPOSED
WALKOUT
PROPOSED
GARAGE
PROPOSED
DRIVEWAY
6-7% SLOPE TO
PLANNED CURB
1028.
3
3
1028.
0
5
10
2
8
.
9
0
1028.
4
6
1028.1
5
1028.
9
1
1028.
2
1
1027.
8
0
EX CB
RIM=1028.80
EX SAN MH
RIM=1028.28
1028.
5
4
1028.17U
N:178459.82
E:520082.74
L=61.71
R=530.00
Δ=6°40'16"
N6
0
°
1
6
'
1
0
"
W
10.
3
8 S29°43'50"W 129.25N23°03'34"E 134.38S5
6
°
2
2
'
3
7
"
E
5
9
.
0
7
S67
°
0
0
'
3
9
"
E
28.
8
2
11.1
0
21.4
6
14.5
0 44.0017.3
3
44.0
0
6.00
13.8
7
6.00
20.4623.548.006.0
4
4.0012.5
0
10.0
0
4.0010.0
10.
04.02.029
20 25.829.4Planned
Sidewalk
Edge of
Pavement
Edge of
Gravel 48.47 30257 105
1051023.401023.401021.86
1028.991031.601031.60
1031.60
1031.60
1031.281031.011030.961029.2210
3
0
.
3
0
H.
P
.
1030.47
H.P.
10
2
9
.
0
3
1031.29
1024
.90
1025.
0
0
102
2
1024
1026
1028
1030
1030
1030
102
8
10
2
6
1
0
2
4
En
d
o
f
C
u
r
b
Pla
n
n
e
d
Cu
r
b
N:178467.19
E:520096.58 1021.501021.501021.50
POR
C
H
6.025303 L2 B3
DATE
REVISION SCHEDULE
DESCRIPTION BY
PROJECT NO.
CAD FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
REVIEWED BY
PROJECT
SHEET
TITLE
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,FILE LOCATION: S:\PROJECTS\25000 PROJ\25300-25399\25303 STREEFLAND PROPERTY - LENNAR - LAKEVILLE MN\25303 CIVIL-SURVEY\SURVEY PRODUCTION DRAWINGS\LOT CERTS\BLOCK 3\LOT 2\25303 L2 B3.DWG 1OF
CERTIFICATE
OF SURVEY
1
21-25303
6/28/23
LAKEVILLE MINNESOTA
JW
MAS
LENNAR
CORPORATION
CASLANO
LOT 2, BLOCK 3
I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A
DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF
MINNESOTA.
DATE LIC. NO.6/28/23 45817
MARK A. SCHWANZ
CONSTRUCTION NOTES:
1.Install rock construction entrance.
2.Install silt fence as needed for erosion.
3.Sidewalks shall drain away from house a minimum of
1%.
4.Contractor must verify driveway design.
5.Contractor must verify service elevation prior to
construction.
6.Add or remove foundation ledge as required.
GENERAL NOTES:
1.Grading plan by ISG last dated May 9, 2022 was used
to determine proposed elevations shown hereon.
2.This survey does not purport to show improvements or
encroachments, except as shown, as surveyed by ISG
or under my direct supervision.
3.Proposed building dimensions shown are for horizontal
location of structures on the lot only. Contact builder
prior to construction for approved construction plans.
4.No specific soil investigation has been performed on
this lot by the surveyor. The suitability of soils to
support the specific house proposed is not the
responsibility of the surveyor.
5.If building footprint exceeds the building pad, additional
earthwork and testing will be required to meet the
requirements as outlined within the geotechnical report.
6.This certificate does not purport to show easements
other than those shown on the recorded plat.
7.Bearings shown are based on the Final Plat.
8.Site address is 18040 Hinckley Avenue, Lakeville, MN
55044
9.House/Basement type: Washburn EH05 A3 - Left -
Walkout
10.Building dimensions shown are based on First Floor
Plan.
11.Proposed Contours are shown hereon.
12.Topographic survey was completed on June 22, 2023.
13.Driveway slope to existing bit pavement is over 10%.
Driveway slope to planned curb should be between
6-7%.
BENCHMARK:
Top nut fire hydrant located in the NE quadrant of Hideaway
Trail and Highview Avenue.
Elevation = 1038.03 feet
AREA TABLE:
House/Garage Area = 1,875 sq. ft.
Porch Area = 51 sq. ft.
Driveway/Walk Area = 794 sq. ft.
Total Impervious Area = 2,720 sq. ft.
Lot Area = 9,365 sq.ft.
Impervious Coverage = 29.0%
HOUSE ELEVATIONS:Proposed/As-Built
Garage Floor = 1031.6
Top of Foundation = 1031.9
Lowest Floor = 1023.9
Lowest Opening = 1023.9
LEGEND
Proposed Building
Sanitary Line
Water Line
Storm Line
Water's Edge (ponding)
Curb Stop
Fire Hydrant
Water Valve
Manhole/Catch Basin
Cleanout
Set Lath at Property Corner
Offset Iron
Existing Contour
Proposed Contour
Proposed Elevation
Proposed Spot Elevation
Existing Spot Elevation
Surface Drainage Direction
>
>>
I
982.2
982
982.
5
985.0
5
0
SCALE IN FEET
10 20
W
Note: Cut and fill quantities include building
excavation, driveway, and lot grading.
GRADING QUANTITIES (CY)
Calc Common Cut -10
Calc Common Fill 33
Driveway*-21
Basement Slab -37
Contracted Amount -71
Additional Amount -0
Sand -7
Swell 20%7
Total Cut -146
Total Fill 40
Total (±)-106
Zoning = RS-4
FY - 20' House, 25' Garage
SY - 7' Interior, 20' Corner
RY - 30'
SY Buffer - 30'
RY Buffer - 50'
EROSION CONTROL
MUST BE INSTALLEDBEFORE EXCAVATION
The curb box, drain tile cleanout, and catch
basin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.
*Maintain 6" between bottom of siding and sod.*No structures in easements.
*Draintile connection required.
ENGINEERING REVIEWED
Date:__________________07/26/2023 hdunne