HomeMy WebLinkAboutLA215893 - 19655 Harbor Drive - Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"SMARTSIDE SHAKES TYP.6" SMARTSIDE FRIEZE BOARDTYP. @ FRONTSMARTSIDE LAP SIDING @ FRONT TYP.CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDE TRIM @ FRONTTYP.SEE COLUMN DETAILDETAIL SHEET A-501ADDRESS STONE4" SMARTSIDE TRIM @ WINDOWS & DOORSTYP. @ FRONT6" SMARTSIDE STORYBOARD8" 12"SMARTSIDE BOARD& BATTEN TYP.7" / 12"3' - 0"ARCHED TRIM ARCHED TRIM ARCHED TRIM GARAGE PLATE HEIGHT 10' - 9 3/8"7" / 12"32036 NVPWGR.O. 2' -0" x 3' -6"H.H. 9' -8 19/32"5' - 0"8" 12"3' - 6"24" RETURNS TYP.8" / 12"8" / 12"7" 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS @ SIDES & REAR8" 12"8" 12"7" / 12"24" RETURNS TYP.7" 12"8" / 12"8" / 12"8" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:37 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-201OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODEL1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SECTIONS - SCHEDULESA-504 DETAILS1/8" = 1'-0"A-2013LEFT ELEVATION1/8" = 1'-0"A-2014REAR ELEVATION1/8" = 1'-0"A-2015RIGHT ELEVATIONSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode08/01/2023dmathews
11' - 10"2' - 0"0' - 2"20' - 6"20' - 8"2' - 2 1/2"16' - 3" M.O.2' - 2 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB11' - 8"8' - 0"16' - 0"6' - 0"52' - 0"42' - 2"9' - 10"2' - 0"2' - 0"5' - 10"36' - 2"6' - 0"19' - 8"15' - 9 1/4"4' - 2 3/4"4' - 2 3/4"11' - 11 1/4"4' - 7"7' - 2"0' - 9 1/2"6' - 7"22' - 10 1/2"22' - 8"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATION30' - 0"22' - 0"52' - 0"3' - 9"6' - 1":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE9' - 10"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.18' - 0"42' - 0"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY, BOTH SIDES.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY60' - 0"LEAVE A 12" GAP IN THE FOOTING FOR PLUMBING22' - 4"41' - 2"18' - 10"EGRESS WELL8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.10' - 4"8' - 0"4' - 0"ANCHOR BOLTS ON EACH SIDEOF BEARING POINT TYPICAL14' - 0"4' - 0"10' - 0"15' - 0"17' - 0"13' - 10"60' - 0"0' - 4"48" x 48" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY1' - 9 1/4"28' - 2 3/4"1' - 4 1/2"M.O.3' - 3"13' - 4 1/2"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:39 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-401OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODEL1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UNEXCAVATEDFURNACESUMPW. H.F. D.BATHMECHANICAL/STORAGE11' - 10"2' - 0"0' - 2"20' - 6"20' - 8"42' - 2"9' - 10"2' - 2 1/2"16' - 3" M.O.2' - 2 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"2' - 0"2' - 0"5' - 10"36' - 2"6' - 0"12' - 2"4' - 0"4' - 0"16' - 0"UNEXCAVATED14' - 0"4' - 0"10' - 0"15' - 0"17' - 0"30' - 0"22' - 0"6' - 0"16' - 0"62/8 x 6/8R.O. 2' -10" x 6' -11"SET SILL 6" ABOVE TRT'D PLATE20' - 0"16' - 2"6' - 7"3' - 9"9' - 0"3' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.5' - 0"5' - 10"8' - 10"3-14" FLUSH LVL24" CANT. ABOVE0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE/ SHEATHING,NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLABBEDROOM #518' - 10 3/4"10' - 1 1/4"1' - 9"11' - 3"4' VANITY2x6SMOKEDET.CO DET.FAMILY ROOM6' - 8"4' - 2"KNEE WALL W/ PAINTED SPINDLESFLOOR GIRDER2-2x102-2x1022' - 8"11' - 8"8' - 0"19' - 8"52' - 0"52' - 0"ANCHOR BOLTS ON EACH SIDEOF BEARING POINT TYPICAL3-2x109' - 10"AIR EX.2-2x10 FLUSH22' - 4"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING42' - 0"18' - 0"60' - 0"64030 NVPWG TEMP.R.O. 4' -0" x 3' -0"H.H. 1' -11 1/4"48" F.G. SHWR42/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"CLOSET #5SMOKEDET.R & SH. @ 65"2' LINEN41' - 2"18' - 10"13' - 10"95036E NVG1R.O. 5' -0" x 3' -6"H.H. 6' -10"EGRESS WELL4' - 0"8' - 0"10' - 4"2-9 1/2" LSL12/4 x 6/8R.O. 2' -6" x 6' -11"BAR SINK2' - 0"LVTCARPETU.C. REF12" FLOATING SH.0' - 4"BAR60' - 0"1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:40 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-402OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODELFAN
42' - 0"10' - 0"42' - 0"18' - 0"36" REFKITCHENDINING ROOMGREAT ROOM8" BOX VAULTFOYERSINKDWPORCH6' - 0"36' - 0"6' - 0"2' - 0"2' - 0"124/0 x 6/8 FULL VIEWR.O. 4' -2" x 6' -11"11' - 6"7' - 4"20' - 6"20' - 8"2' - 3"16' - 0"2' - 3"2' - 4"16' - 0"2' - 4"1' - 0"9' - 6"1' - 0"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING 1/2" GYP. BD. ON GARAGE WALLSR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE1416' x 8' O.H. GARAGE DOORTYP.0' - 4 1/2"16" SH.113/0 x 6/8 W/ 12" D.S. SL'S4' - 0"8' - 0"2' - 0"14' - 0"5' - 9"5' - 9"3' - 7"4' - 3"52' - 0"52' - 0"6' - 0"16' - 0"17' - 0"15' - 0"10' - 0"22' - 0"3' VANITYBENCHGARAGE2' - 0"20' - 8"12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH. @ 65"4' - 0"4' - 6"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"KNEE WALL W/ PAINTED SPINDLESRECYCLE@ 6' -10" H.H.ABOVE LANDING16' - 0"20' - 0"2' - 7"3' - 5"DOUBLE FRAMEDWALL FORREF RECESS 39"x73"U.C. LIGHT9' - 0"8' - 0"7' - 6"7' - 6"2' - 3"7' - 9"13' - 6"5' - 3"3' - 3"12' - 0"4' - 0"4' - 0"16' - 0"5' - 0"6' - 8"7' - 8"5' - 0"5' - 10"0' - 10"30' - 4"6' - 9"5' - 0"3' - 6"6' - 9"GIRDER TRUSSGIRDER TRUSSFLOORGIRDERSEE COLUMN DETAILSHEET A-5012-2x10 CONT.2-2x103-14" LVL FLUSH2-11 7/8"LSL FLUSH2-11 7/8" LSL2-2x122-9 1/2" LSL DROPPED 2-7 1/4" LSL CONTINUOUS DROPPED2-2x10 W/2 TRIMMERS3-2x6STAGGEREDUPPERS7' - 10"2' - 7"3' - 5"END PANELOVEN /MICRO9' - 6"4' - 1 3/4"3' - 6"5' - 6"82/8 x 6/8 FULL VIEWR.O. 2' -9" x 6' -8 1/4"EQEQMECHANICALCHASE 2-2x102-2x12 CONT.2-2x10ATTICACCESSCS-WSP6' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP10' - 0" B.W.P.CS-WSP2' - 9" B.W.P.CS-WSP8' - 0" B.W.P.CS-WSP8' - 0" B.W.P.WALL ABOVE BEARING ONFLOOR TRUSSES3-2x62-2x102-2x102-9 1/2" LSL2' - 0"5x5 PSL2' - 10"3' - 8"2' - 6"36" GAS COOKTOP W/WOOD HOODABOVE12" SH.2-2x10 FLUSHCS-WSP3' - 3" B.W.P.30' - 0"22' - 0"FLOOR GIRDER10' - 0"CS-WSP12' - 6" B.W.P.R & SH. @ 65"12/4 x 6/8R.O. 2' -6" x 6' -11"U.C. LIGHTU.C. LIGHT72/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"20" FLOOR TRUSSESPER MFG. SPACING5' - 10"5' - 0"20" FLOOR TRUSSESPER MFG. SPACING13' - 0"16' - 2"4' - 6"20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHHUS484484050E NVG1R.O. 4' -0" x 5' -0"H.H. 6' -10"443650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"484050E NVG1R.O. 4' -0" x 5' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"126050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"74040 NVPWG TEMP.R.O. 4' -0" x 4' -0"H.H. 11' -11 1/8"PANTRY43650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"103/0 x 6/8 OPG.30" PANTRYMUD RM.12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH. @ 65"11' - 0"2' - 0"BUILT-INBUILT-INSET FIREPLACE 18" A.F.F.W/ MANTEL 2-14" LVL FLUSH2-14" LVL FLUSH 41' - 2"18' - 10"60' - 0"1' - 0"5' - 0"HHUS410TAPERED END CUT ALLOWED 2-2x10 W/2 TRIMMERS10' - 0" (BRACED WALL LINE SPACING)16' - 0" (BRACED WALL LINE SPACING)21' - 0" (BRACED WALL LINE SPACING)26' - 0" (BRACED WALL LINE SPACING)21' - 0" (BRACED WALL LINE SPACING)CS-WSP2' - 8" B.W.P.CS-PF1' - 6" B.W.P.CS-PF1' - 6" B.W.P.OFFICE1' - 2"5' - 0"CS-WSP2' - 8" B.W.P.1' - 9"4' - 0"PFH2' - 4"PFH2' - 3"PFH2' - 3"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"POWDER0' - 10"19' - 4"22' - 8"2 TRIMMERS 2' - 1"60' - 0"93/0 x 6/8R.O. 3' -2" x 6' -10 1/4"15' - 0"3' - 0"ROUGH-IN FOR FUTURE GARAGE HEATER U.C. REF36" GAS F.P.PFH2' - 4"2-11 7/8" LSL1416' x 8' O.H. GARAGE DOOR5x7 PSL4-2x6GIRDER TRUSS5x5 PSL 2 TRIMMERS 2-2x1042' - 0" (BRACED WALL LINE SPACING)18' - 0" (BRACED WALL LINE SPACING)18' - 10" (BRACED WALL LINE SPACING)41' - 2" (BRACED WALL LINE SPACING)16.0' REQUIRED 10.6'REQUIRED 7.9'REQUIRED 21.0' G.B.REQUIRED 9.0'REQUIRED 10.6'REQUIRED 21.0' G.B.REQUIRED 9.0'REQUIRED 16.0'REQUIRED 16.0'REQUIRED 15.6'REQUIRED 15.6'REQUIRED 15.6'REQUIRED CS-WSP2' - 9" B.W.P.CS-PF1' - 6" B.W.P.CS-WSP13' - 6" B.W.P.METHOD G.B.4' - 0" BOTH SIDES METHOD G.B.4' - 0" BOTH SIDES METHOD G.B.4' - 0" BOTH SIDES CS-WSP2' - 3" B.W.P.CS-WSP6' - 0" B.W.P.SHEATHING UNDER GYP. BD. FOR WALL BRACING REQUIREMENTS 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:42 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-403OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODELFANBWPsAboveVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.
BEDROOM #4BATHBEDROOM #3OWNER'S SUITE12" BOX VAULTHALLOWNER'S BATH7'-6" VANITYCLOSETR & SH. @ 65"BEDROOM #215' - 6"9' - 0"17' - 6"17' - 0"15' - 0"10' - 0"42' - 0" (BRACED WALL LINE SPACING)42' - 0" (BRACED WALL LINE SPACING)32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"42/6 x 6/8R.O. 2' -8" x 6' -11"2' LINEN3' VANITY3' VANITY42/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"LAUNDRYCLOSETCLOSET #1TILESHOWER42" WALL W/GLASS PANEL ABOVE7' - 9"7' - 9"4' - 6"4' - 6"8' - 9"8' - 9"20' - 0"20' - 0"CONTROLS5' - 6 1/8"7' - 0 7/8"4' - 5"7' - 6"7' - 6"40' - 0"6' - 0"11' - 0 1/4"28' - 11 3/4"16' - 0"4' - 0"4' - 0"16' - 0"5' - 0"5' - 0"1' - 8"30' - 4"10' - 8"5' - 2"1' - 6 1/4"4' - 0"4' - 1 3/4"6' - 1 3/4"10' - 4 1/4"9' - 7"5' - 6 3/4"1' - 2"8' - 6 1/2"3' - 7 3/4"8' - 1"5' - 5"13' - 7"2' - 6"3' - 8"3' - 0"3' - 2"5' - 5"2' - 8"12' - 0"7' - 10"2' - 4 1/4"6' - 0"9' - 1 3/4"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.ATTICACCESS2-2x102-9 1/2" LSLW/ 2 TRIMMERSKNEE WALL W/ PAINTED SPINDLESR & SH. @ 48"22/4 x 6/8 OPG.52/6 x 6/8 PKTR.O. 5' -2" x 6' -11"3' VANITY48" F.G. SHWR42/6 x 6/8R.O. 2' -8" x 6' -11"BATHTYP.2' - 0"2-2x102-2x102-2x102-2x1062/8 x 6/8R.O. 2' -10" x 6' -11"R & SH. @ 65"SMOKEDET.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.3-2x102' - 0"3' - 3"MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.6' - 0"40' - 0"46' - 0"46' - 0"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES105040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"138050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"54020 NVPWG TEMP.R.O. 4' -0" x 2' -0"H.H. 6' -10"138050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"22036 NVC1R.O. 2' -0" x 3' -6"H.H. 6' -10"116020 NVA3R.O. 6' -0" x 2' -0"H.H. 6' -10"52/6 x 6/8 PKTR.O. 5' -2" x 6' -11"42/6 x 6/8R.O. 2' -8" x 6' -11"2' - 4"2' - 2"2' - 7"2' - 0"6' - 0"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"2' - 11 1/2"CURBHEADDOUBLE FRAME PLUMBING WALLACCENT WALLCLOSET#212/4 x 6/8R.O. 2' -6" x 6' -11"2' LINEN12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"6' FREESTANDING TUB138050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"136/0 x 6/8R.O. 6' -2" x 6' -11"5' - 8"7' - 8"2' - 8"1'-6" LINEN2-2x103' - 3"4' - 1 3/4"41' - 0" (BRACED WALL LINE SPACING)41' - 0" (BRACED WALL LINE SPACING)CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.5' TUB/SHWRCORNER SEAT(2) SHAMPOO SHELVES 12/4 x 6/8R.O. 2' -6" x 6' -11"2' - 0"2' - 0"2x62x62x6R & SH. @ 65"WASHERDRYERSINKTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:44 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-404OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODEL1/4" = 1'-0"A-4041UPPER FLOOR PLANTemperFANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATIONALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS1' - 6"2x4 TYP.2x4 @ TOPSOFFITFRONTSIDETOP VIEWSMOOTHSMARTSIDETYPICAL4x4 POSTFRAMING1' - 6"1' - 6"1' - 6"1' - 3"1' - 3"1' - 8"1' - 8"18" OVERHANGS & 12" RAKES TYP.STANDARD ENERGY HEELS @ 8:128 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 4 ROOF VENTSREQUIRED@ GARAGE 8" / 12"8" / 12"8" / 12"8" / 12"STANDARD ENERGY HEELS @ 7:12W/ 8:12 FASCIA LINES TO MATCH7" / 12"7" / 12"8" / 12"8" / 12"7" / 12"7" / 12"6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:46 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-501OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODELWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 3 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2036 NVC1 2' - 0" 3' - 6" 6' - 10"3 VECTOR ENVISION SERIES 1 2036 NVPWG 2' - 0" 3' - 6" 9' - 8 19/32"4 VECTOR ENVISION SERIES 6 3650 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"5 VECTOR ENVISION SERIES 1 4020 NVPWG TEMP. 4' - 0" 2' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 4030 NVPWG TEMP. 4' - 0" 3' - 0" 1' - 11 1/4"7 VECTOR ENVISION SERIES 1 4040 NVPWG TEMP. 4' - 0" 4' - 0" 11' - 11 1/8"8 VECTOR ENVISION SERIES 2 4050E NVG1 4' - 0" 5' - 0" 6' - 10"9 VECTOR ENVISION SERIES 1 5036E NVG1 5' - 0" 3' - 6" 6' - 10"10 VECTOR ENVISION SERIES 1 5040E NVG1 5' - 0" 4' - 0" 6' - 10"11 VECTOR ENVISION SERIES 1 6020 NVA3 6' - 0" 2' - 0" 6' - 10"12 VECTOR ENVISION SERIES 1 6050E NVG1 6' - 0" 5' - 0" 6' - 10"13 VECTOR ENVISION SERIES 3 8050E NVGE 8' - 0" 5' - 0" 6' - 10"3/8" = 1'-0"A-5012TYP. POURED WALL SECTION1/2" = 1'-0"A-5013GARAGE CEILINGROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR MECHANICAL /STORAGE . 218 SF 8' - 2" MECHANICALS MY VARYLOWER FLOOR BEDROOM #5 CARPET 170 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 479 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 76 SF 8' - 2"LOWER FLOOR CLOSET #5 CARPET 57 SF 8' - 2"LOWER FLOOR BAR LVT 36 SF 8' - 2"LOWER FLOOR BATH VINYL 50 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 114 SF 9' - 1 1/8"MAIN FLOOR STAIRS CARPET 83 SF 9' - 1 1/8"MAIN FLOOR PORCH CONCRETE 128 SF 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 991 SF 10' - 9 3/8" FINISH PER CODEMAIN FLOOR MUD RM. VINYL 76 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 24 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 267 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 183 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 239 SF 9' - 1 1/8" 8" BOX VAULTMAIN FLOOR FOYER WOOD 131 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 30 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 196 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 212 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 242 SF 8' - 1 1/8" 12" BOX VAULTUPPER FLOOR HALL CARPET 141 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 157 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 27 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 21 SF 8' - 1 1/8" .UPPER FLOOR CLOSET #1 CARPET 67 SF 8' - 1 1/8" .UPPER FLOOR CLOSET#2 CARPET 37 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY LVT 59 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S BATH TILE 165 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 110 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 50 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 92 2/4 x 6/8 OPG. 13 2/4 x 6/8 PKT 4' - 10" 6' - 11" 44 2/6 x 6/8 2' - 8" 6' - 11" 55 2/6 x 6/8 PKT 5' - 2" 6' - 11" 26 2/8 x 6/8 2' - 10" 6' - 11" 37 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 18 2/8 x 6/8 FULL VIEW 2' - 9" 6' - 8 1/4" 19 3/0 x 6/8 3' - 2" 6' - 10 1/4" 110 3/0 x 6/8 OPG. 111 3/0 x 6/8 W/ 12" D.S. SL'S 112 4/0 x 6/8 FULL VIEW 4' - 2" 6' - 11" 113 6/0 x 6/8 6' - 2" 6' - 11" 114 16' x 8' O.H. GARAGE DOOR 21/2" = 1'-0"A-5011TYP. COLUMN1/8" = 1'-0"A-5014ROOF PLAN3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:1/2" = 1'-0"A-5015TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5016TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5017TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5018TYP. HOUSE/GARAGE WALL
FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP. FASTENKING STUD TO HEADERW/ 6-16d SINKERS.MIN. 7/16" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).FRONT ELEVATIONMIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 7/16" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INFRAMING (STUDS AND SILLS) AS SHOWN TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALEXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOODSTRUCTURAL PANELS.OVERLAP0' - 9 1/4" MIN.WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTNAIL SOLE PLATE TO JOISTPER TABLE R602.3(1)WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOISTATTACH SHEATHING TOBAND OR RIM JOIST WITH8d COMMON NAILS @3" O.C. TOP @ BOTTOMFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/19/2023 10:24:47 AMTHE AUGUSTIN RESIDENCEL12, B1 -BERRES RIDGE 8TH ADDITION19655 HARBOR DRIVELAKEVILLE, MN 55044A-504OTT3657.12.23 CB175212779207.19.23 CB5.10.23 CB8'- 1 /18"9'- 1 /18"8'-4" POUR3949MAVERICK MODEL3/8" = 1'-0"A-5041METHOD CS-PF3/8" = 1'-0"A-5042METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS
Date Certificate Posted
X Passive (No Fan)
Active (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
Other Please Describe Here
R-15 X
R-20 X
R-20 X
R-20 X
R-49 X
R-49 X
R-30 X
R-30 X
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
90,000 Capacity
in Gallons:
Other, describe:
AFUE or
HSPF%
93
Cfm's
" round duct OR
" metal duct
Not required per mech. code
X Passive
Low: Other, describe:
X Low:
Location of fan(s), describe: Cfm's
X " round duct OR 6" flex
" metal duct
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
3.5
Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.7/19/2023
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
One Ten Ten Homes, LLC
MN License Number
Lakeville19655 Harbor Drive
BC730925
Mechanical room
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
70813
Heating Gain Cooling Load
90
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
0.28
Appliances
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply
Mineral Fiberboard Insulation Location
Foam, Closed Cell0.21
Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness: Building envelope air tightness:
Rim Joist (1st Floor)
GPVL5000L 13ACX042 Model
Heating System
Natural Gas
Lennox
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
AO Smith
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency
13
180
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
42545Residential Load Calculation
SEER
/EER
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
ML19309016C
Heating Loss
Manufacturer Lennox
Natural Gas
Output
in Tons:
3.550
Builders Associaton of Minnesota version 101014
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
7/21/23 X
PM