Loading...
HomeMy WebLinkAboutLA217011 - APPROVED - Steve Fetzek Solar Drawings wStamp 08 17 2023 (1)COVER PAGECP 0.0PV SYSTEMAS INDICATEDScale:Project:Dakota ElectricEXISTINGINVISIMOUNTSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAMATTACHMENT LAYOUTSYSTEM LABELING DETAILINVERTER DATA SHEETSHEET INDEXPROPERTY PLANRSD DATA SHEETMODULE DATA SHEETATTACHMENT DATA SHEETPV 1.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:VICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record prior to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.200A200A SUNPOWER U-SERIES 400 WATT MODULES INTEGRATED IQ7HS MICROINVERTERSTHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2023 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESSURGE PROTECTIONPLACARDDC 14.800 KW STCAC 14.208 KW STC37PV 2.0PV 3.1PV 3.2PV 4.0PV 5.0D 6.0D 7.0D 8.0D 9.0D 10.0D 11.0D 12.0D 13.0COVER PAGECP 0.0COMP. SHINGLETRUSS: 2 X 4 @ 24" O.C.37INVERTER CERTIFICATIONPV INSPECTION CHECKLISTD 14.0UTILITYDrawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023MONITORING DATA SHEETRACKING DATA SHEETThese drawings are protected by copyright under US law. Any form ofreproduction is strictly prohibited without prior written approval from Engineerinc.Date Certified andExp. Date : 06/30/2024Signed: 08/17/2023Engineerinc.io,303 N Glenoaks BlvdBurbank, CA 91502 (747) 333-5991 ............................................................................MSP(E) Main Service PanelINDEXAC....................(N) 100A Utility AC(N) MicroinverterNOTE: Conduit in attic shallbe minimum 18 inches from roof sheatingPVS(N) 125A PV Sub Panel ........Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTNOTE: No clearance issueDistance between all equipments is maximum 10"(E) Main MeterMM.....................................SECONDARY INTERCONNECTION.............SOLAR MODULES___SUNPOWER 400 WattModel #SUNPOWER U-SERIESINVERTERINVERTER TYPE: Micro:___ Enphase IQ7HS MicroinvertersModel # IQ7HS-66M-US(240V)Dakota ElectricTOTAL ROOF AREA:2568TOTAL MODULE AREA:81431.69% OF COVERAGESITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:JB(N) Junction Box(N) Solar ModuleEMT Type ConduitFire Setback LineFMT type Conduit3737Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023EQUIPMENT ELEVATIONUtilityACDisconnectFrom roofMainServicePanelPVSNOTE: Keep 3ft clearance from gas meter and AC unit10">10'4'PVS6(N) PV Monitoring System.....200APVS6PM(N) Performance Meter...........PerformaneMeterMainMeterInsideOutside 18'' fire setback36'' fire setback18'' fire setback36'' fire setback36'' fire setback18'' fire setback18'' fire setback18'' fire setbackPMMMMSPACPVSPVS6aaaaaaaababbbbbbbabcccccccccdddddddddJBJBSolar PV Array 117 - SunPower 400W Modules17- Enphase IQ7HS MicroinvertersPitch: 27 DegOrientation: 176 DegSolar PV Array 220 - SunPower 400W Modules20- Enphase IQ7HS MicroinvertersPitch: 27 DegOrientation: 176 DegIcon TrailSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNEConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode08/23/2023dpfannensteinFor each roof plane with a photo-voltaic array, twopathways not less than 36" wide shall be provided fromthe lowest roof edge to ridge on the same roof plane asthe array,on an adjacent roof plane, or straddling thesame and adjacent roof planes. Not fewer than onepathway shall be provided on the street or drivewayside of the house.Not less than an 18" clear setbackis required on both sides of ahorizontal ridge. ELECTRICAL 1-LINEDIAGRAMPV 2.0PV SYSTEMAS INDICATEDScale:Project:Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDesign meet National Electric Code(NEC codes)SUNPOWER U-SERIES 400 WATT MODULES37INTEGRATED ENPHASE IQ7HS MICROINVERTERSSYSTEM RATING AND DER POWER OUTPUTINVERTER:ENPHASE IQ7HSINVERTER MAXIMUM CONTINUOUS OUTPUT:384VASYSTEM POWER OUTPUT:ENPHASE MICROINVERTERS1 PHASE 384VAMAXIMUM OUTPUT CURRENT 1.6AAC PORT BACKFEED CURRENT 0ADC SHORT CIRCUIT CURRENT 15ADC 14.800 KW STCAC 14.208 KW STCDC 14.800 KW STCAC 14.208 KW STCDakota Electricx 384 =14208SECONDARY INTERCONNECTIONREFERENCE POINT OF APPLICABILITY15AEXISTING______ MAINSERVICEPANEL120/240V,1P, 3WGEC(E) GROUNDINGELECTRODE SYSTEM200A125A PV SUB PANEL120/240V, NEMA 3RINSTALL (4)20APV 2-POLE C/B100A FUSED UTILITY ACDISCONNECT,WITH 80A FUSES,VISIBLE-OPEN LOCKABLE,READILY ACCESSIBLE,NEMA3R, 120 / 240V(NEW)GECAdd 2nd Ground rod andtie it to the existing ground rod.Line Side TapEXISTINGNON CENTER _____MAIN C/B59.2 A59.2 ANOTE: Keep 3ft clearance from gas meter and AC unit3737200AWire Size90C wirerating12 AWGTHWN-2, THHNXHHW-2, USE-210 AWGTHWN-2, THHNXHHW-2, USE-38 AWGTHWN-2, THHNXHHW-2, USE-4304055Temperature rating ofConductors-Ambient Temp.(114-122F) NEC 310.15(B)(2)(a)Number of Current carrying Conductors NEC 310.15(B)(16)4-67-910-2020A Branch Circuit Rating30A Branch Circuit Rating30 x 0.82=24.640 x 0.82=32.855 x 0.82=45.124.6x0.80= 19.6832.8x0.80= 26.2445.1x0.80= 36.0824.6x0.70= 17.2232.8x0.70= 22.9645.1x0.70= 31.5724.6x0.50= 12.332.8x0.50= 16.445.1x0.50= 22.55YES- 6 or less current carryingconductors in the same conduitYES- 9 or less current carryingconductors in the same conduitYES- 20 or less current carryingconductors in the same conduitYES- 9 or less current carryingconductors in the same conduitYES- 3 or less current carryingconductors in the same conduitNOSurge ProtectionMNSPD-300-ACDrawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023AtticWall(8) #12 AWG THWN/THWN-2(1)#12 AWG GND3/4" EMT, 2 FEET(3) #2 AL AWG THWN/THWN-2(1) #6 AWG GND1 1/4" SCH 80 PVC, 2 FEET(3) #2 AL AWG THWN/THWN-21 1/4" SCH 80 PVC, 2 FEETMAIN METER120/240V,1P, 3WPVS6MONITORING SYSTEM1BRANCHCIRCUIT-A (2) J BOXNEMA3R16A1-PHASE MICRO-INVERTER UL1741210114.4A29BRANCHCIRCUIT-B (8) #12 AWG THWN/THWN-2(1)#12 AWG GND3/4" FMT, 2 FEETProduction CTsUTILITY PV METER PRODUCTIONMETER SOCKET LABELED INACCORDANCE WITH NEC ANDAHJ REQUIRMENTS LOCATEDWITHIN 5' OF MAIN. INVERTEROUTPUT WIRED TO LOAD SIDETERMINAL OF METER 1 PHASE3-WIRE 120/240VLINELOAD59.2 ASUNPOWER TRUNK CABLE(2) #12 AWG PV WIRE(1) #10 INTEGRATED GROUNDINGFREE IN THE AIR(1) #6 AWG GND129BRANCHCIRCUIT-C129BRANCHCIRCUIT-D 14.4A14.4AConsumption CTs SYSTEMLABELING DETAILPV 3.1PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023PV ARRAYJ BOXPV SUB-PANELACDISCONNECTMAIN SERVICEPANELMETER233321716218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTRATED MAX POWER-FONT CURRENTRATED MAX POWER-FONT VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTMAX RATED OUTPUT CURRENT OFTHE CHARGE CONTROLLER IF INSTALLEDLABEL 21***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECT21SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELS59.2 AProduction MeterLABEL 1PerformanceMeter31 PLACARDPV 3.2PV SYSTEMAS INDICATEDScale:Project:CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 1 OF 2CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 2 OF 2NWESNWES17704 Icon TrailLakeville, MN 5504417704 Icon TrailLakeville, MN 55044Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023SERVICE POINT &UTILITY METERINGPV SYSTEM DISCONNECTFOR UTILITY OPERATIONPV SUB PANELPV MONITORING SYSTEMPERFORMANCE METERSOLAR PV ARRAYSERVICE POINT &UTILITY METERINGPV SYSTEM DISCONNECTFOR UTILITY OPERATIONPV SUB PANELPV MONITORING SYSTEMPERFORMANCE METERSOLAR PV ARRAY PROPERTY PLANPV 4.0PV SYSTEMAS INDICATEDScale:Project:.....................MSPMain Service PanelINDEXAC..................................Utility ACPVSPV Sub Panel ......................Main MeterMM..............................Solar Module.................Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDakota ElectricDrawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023PVS6PV Monitoring System............PM.................Performance MeterPROPERTY LINEPMMMMSPACPVSPVS6181'-10"73'-5"135'-1"73'29'-1"12'-11"40'-3"10'-8"73'-4"DrivewayIcon TrailSCALE:1/16" = 1'-0" 180° 90° 270°0°SWNEDate Certified andExp. Date : 06/30/2024Signed: 08/17/2023Engineerinc.io,303 N Glenoaks BlvdBurbank, CA 91502 (747) 333-5991 ATTACHMENTLAYOUTPV 5.0PV SYSTEMAS INDICATEDScale:Project:DESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules48.5Total Module Weight (lbs)Rack Weight (lbs)MicroInverters Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)1794358.988.062240.96904824.898142.75RAIL ATTACHMENTTRUSS: 2 X 4 @ 24" O.C.37371 Layer of .Plywood & Building FeltSolar Module6"AttachmentROOF SECTION DETAILTRUSS: 2 X 4 @ 24" O.C.COMP. SHINGLEPrior to the commencement of work, thecontractor shall verify the existing roof andframing conditions. Notify New@engineerinc.ioof any Discrepancies prior to startingconstruction. Prior to the commencement ofwork, the contractor shall inspect framing forany damage such as water damage, crackedframing, etc. and These Plans are stamped forstructural code compliance of the roof framingsupporting the proposed PV installationreference only. These plans are not stampedfor water leakage. PV modules, racking, andattachment components must followmanufacturer guidelines and requirements.Attachments to be installed in a staggeredorientation to properly distribute loads.Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023LightSpeed FlashingSupport BlockEPDM WASHERROOF ASSEMBLYPEGASUS COMP SHINGLE DETAILS27'-10"24'-5"Date Certified andExp. Date : 06/30/2024Signed: 08/17/2023Engineerinc.io,303 N Glenoaks BlvdBurbank, CA 91502 (747) 333-5991 PV 6.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023MONITORINGDATA SHEET INVERTERDATA SHEETD 7.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023 RSDDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023 MODULEDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023 RACKINGDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023 ATTACHMENTDATA SHEETD 11.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023 D 12.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023SURGEPROTECTION D 13.0PV SYSTEMAS INDICATEDScale:Project:INVERTERCERTIFICATIONDrawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023 D 14.0PV SYSTEMAS INDICATEDScale:Project:PV INSPECTIONCHECKLISTDrawn by: New@engineerinc.ioProject Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comREVISION DATE: 08/17/202317704 Icon TrailLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE: Steve Fetzek08/16/2023Wolf RIver ElectricLakeville, MN 5504417704 Icon Trail