Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA217147 - APPROVED - Jo Wanner Stamped CAD 07-21-23
SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-1.0 COVER PAGE HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 60A AC DISCONNECT WITH 50A FUSES LINE SIDE TAP 200A MCB WITH 200A BUSBAR WIND SPEED SNOW LOAD 110 MPH 50 LB/SQ.FT. TABLE OF CONTENT NO.TITLE SITE PLAN ARRAY LAYOUT STRUCTURAL ELECTRICAL LINE DIAGRAM ELECTRICAL CALCULATIONS LABELS DATASHEETS COVER PAGE PLOT PLAN ATTACHMENT PV - 2.0 PV - 3.0 PV - 4.0 PV - 5.0 PV - 6.0 PV - 7.0 PV - 1.0 PV - 8.0 PROJECT SITE SCALE: NTS SITE MAP PROJECT SITE SCALE: NTS VICINITY MAP PHOTOVOLTAIC SYSTEM 18998 IBARRA TRAIL LAKEVILLE MN 55044 JO WANNER/JIM E PERRY/ KELLEY C PERRY REFERENCE CODES: APPLICABLE CODES: NEC 2020 2018 IBC 2018 IRC 2020 MINNESOTA STATE BUILDING CODE 2020 MINNESOTA RESIDENTIAL BUILDING CODE 2020 MINNESOTA STATE ENERGY CODE 2020 MINNESOTA FIRE CODE 2020 NATIONAL ELECTRICAL CODE PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT 3 CIRCUITS OF 10 MODULES (15) HOYMILES HM-600NT (30) HYPERION HY-DH108P8 400B 590 VA MAX. CONT. POWER = 8.85 KWP 600 VA PEAK POWER = 9 KWP 12 KWP Signed 7/21/2023 JBPM AC (N) MAIN SOLAR FUSED AC DISCONNECT ROOF 1 ARRAY 1 (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (OUTSIDE) ROOF 2 ARRAY 2 (N) SOLAR MODULES 3' SETBACK 18" SETBACK (N) AC DISTRIBUTION PANEL U DP MSP DRIVEWAY 190TH ST WIBARRA TRAIL(N) NEMA 3R RATED TRANSITION BOX (N) PRODUCTION METER NO SOLAR MODULE SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-2.0 SITE PLAN HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401PROJECT SITE SCALE: NTS SITE MAP SCALE: NTS SITE PLAN PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 3 CIRCUITS OF 10 MODULES (15) HOYMILES HM-600NT (30) HYPERION HY-DH108P8 400B 590 VA MAX. CONT. POWER = 8.85 KWP 600 VA PEAK POWER = 9 KWP 12 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 60A AC DISCONNECT WITH 50A FUSES LINE SIDE TAP 200A MCB WITH 200A BUSBAR ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2"x 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY TOTAL 30 4 26 270°27°2 90°27°1 NOTE : PROVIDING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA, WHEN THE ARRAYS TAKE LESS THAN 33% WE CAN JUSTIFY 18" SETBACKS FROM RIDGE ROOF COVERAGE AREA CALCULATION AREA OCCUPIED ON ROOF PERCENTAGE OF TOTAL ARRAY TOTAL AREA OF ARRAY TOTAL AREA OF ROOF 2602.95 SQ. FT 630.58 SQ. FT 24.23% N Signed 7/21/2023 Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 08/25/2023dpfannenstein For each roof plane with a photo-voltaic array, two pathways not less than 36" wide shall be provided from the lowest roof edge to ridge on the same roof plane as the array,on an adjacent roof plane, or straddling the same and adjacent roof planes. Not fewer than one pathway shall be provided on the street or driveway side of the house. Not less than an 18" clear setback is required on both sides of a horizontal ridge. 1'-7"17'-2"2'3'-1" 45'-7" 2'-6"ROOF - 1 N13'-7"5'-8"1'-6"14'-4"15'-2"3' ROOF - 2 N18" SETBACK 3' SETBACK NO MODULE ROOF 1B ROOF 1A SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-3.0 ARRAY LAYOUT HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401- VENT, ATTIC FAN (ROOF OBSTRUCTION) - MOUNTS - COUPLING LEGEND - ROOF SETBACK 29'-1"6" SCALE: NTS SIDE ELEVATION SCALE: NTS ARRAY LAYOUT PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 3 CIRCUITS OF 10 MODULES (15) HOYMILES HM-600NT (30) HYPERION HY-DH108P8 400B 590 VA MAX. CONT. POWER = 8.85 KWP 600 VA PEAK POWER = 9 KWP 12 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 60A AC DISCONNECT WITH 50A FUSES LINE SIDE TAP 200A MCB WITH 200A BUSBAR ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2"x 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY TOTAL 30 4 26 270°27°2 90°27°1 Signed 7/21/2023 125'-2"111'-6"127'-1"111'-5"18'-10"43'-2"19'-11" 61'-3"JBPM AC (N) MAIN SOLAR FUSED AC DISCONNECT ROOF 1 ARRAY 1 (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (OUTSIDE) ROOF 2 ARRAY 2 (N) SOLAR MODULES 3' SETBACK 18" SETBACK (N) AC DISTRIBUTION PANELUDP MSP DRIVEWAY 190TH ST WIBARRA TRAIL(N) PRODUCTION METER (N) NEMA 3R RATED TRANSITION BOX PROPERTY LINE NO SOLAR MODULE PM ACU DP MSP SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-4.0 PLOT PLAN HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 3 CIRCUITS OF 10 MODULES (15) HOYMILES HM-600NT (30) HYPERION HY-DH108P8 400B 590 VA MAX. CONT. POWER = 8.85 KWP 600 VA PEAK POWER = 9 KWP 12 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 60A AC DISCONNECT WITH 50A FUSES LINE SIDE TAP 200A MCB WITH 200A BUSBAR ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2"x 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY TOTAL 30 4 26 270°27°2 90°27°1 SCALE: 1"=16' PLOT PLAN N Signed 7/21/2023 ROOF 1A&2 ATTIC1'-2" 4'-11"6'-6"5'-9" 20'-7" 27° 1'-2" 4'-11"6'-6"5'-9" 20'- 7 " 27° 1/2" OSB WITH ASPHALT SHINGLES ROOF TRUSSES 1'-2" 5'-7"6'-9" ROOF 1B ATTIC 1/2" OSB WITH ASPHALT SHINGLES ROOF TRUSSES 15'-1" 27° SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-5.0 STRUCTURAL HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401ROOF SCALE: NTS KEY PLAN PV MODULE FOOT SPACING IS 48" O.C. ACROSS PANEL WIDTH WITH 2 ROWS PER MODULE TYPICAL LAYOUT PROVIDES AN AVERAGE OF 1.6 FEET PER MODULE. MODULE WEIGHT DISTRIBUTED PER MOUNTING FOOT = 52.48 LBS./1.6 FEET = 32.8 LBS./MTG. FOOT. MODULE = 52.48 LBS. OVER 21.015 SQ.FT. = 2.497 LBS/SQ.FT. AREA = 67.79" x 44.64" NOMINAL (21.015 SQ.FT.) WEIGHT = 52.48 LBS. MOUNTING LOAD CALCULATION SMART SLIDE #12 WOOD SCREWS 2 PER MOUNTS MINIMUM OF 2" EMBEDMENT ROOF FRAMING ROOF DECKING SCALE: NTS ATTACHMENT DETAILS SCALE: NTS ATTIC DETAILS PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 3 CIRCUITS OF 10 MODULES (15) HOYMILES HM-600NT (30) HYPERION HY-DH108P8 400B 590 VA MAX. CONT. POWER = 8.85 KWP 600 VA PEAK POWER = 9 KWP 12 KWP ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2"x 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY TOTAL 30 4 26 270°27°2 90°27°1 RACKING SPECIFICATION MIN/MAX ROOF SLOPE MAX ANCHOR SPACING (35MM/40MM) MAX ANCHOR SPACING (32MM) MAX MODULE SIZE MODULE CANTILEVER 1/2:12 / 12:12 48" 67.79" X 44.64" X 1.18" MAXIMUM CANTILEVER IS 1/3 BRACKET SPACING WEIGHT (INCLUDING FRAME) MODEL FORMAT MODULE SPECIFICATION HY-DH108P8 400B 67.79" ~ 44.64" ~ 1.18" 52.48 LBS GENERAL NOTES 1.SOLAR PANELS SHALL NOT EXCEED ANY PART OF ROOF EDGE OR PEAK. NO 1AROOF NO 2 ROOF NO 1B Signed 7/21/2023 (N) AC DISCONNECT FUSIBLE W/ FUSES, VISIBLE-LOCKABLE LABELED 240V/ NEMA 3R60A 50A PV PRODUCTION METER MBOTTOM TOP PV PRODUCTION METER MILBANK U4518-XL-W 200A,600V SINGLE PHASE FORM 2S (E) LOADS MAIN DISCONNECT UTILITY SERVICE 120/240V SINGLE PHASE GROUNDING L1 G N-G SPLICED INTO THE LINE SIDE OF (E) MAIN SERVICE PANEL OUTSIDE HOUSE INSIDE HOUSE (E) RATED MAIN SERVICE PANEL 200A 200A = NEMA3R RATED JUNCTION BOX: SHALL COMPLY W/ NEC 110.3 2P - 20A 2P - 20A 2P - 20A (N) AC DISTRIBUTION PANEL 1 1 1 2 = 2 == 2 == 9 10 9 10 9 10 CIRCUIT 3 : 10 MODULES CIRCUIT 2 : 10 MODULES CIRCUIT 1 : 10 MODULES NAME : GREG MARTIN LICENSE NO: 25250 SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-6.0 ELECTRICAL LINE DIAGRAM HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401SCALE: NTS ELECTRICAL LINE DIAGRAM PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 3 CIRCUITS OF 10 MODULES (15) HOYMILES HM-600NT (30) HYPERION HY-DH108P8 400B 590 VA MAX. CONT. POWER = 8.85 KWP 600 VA PEAK POWER = 9 KWP 12 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 60A AC DISCONNECT WITH 50A FUSES LINE SIDE TAP 200A MCB WITH 200A BUSBAR CONDUIT TAG QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE A -NA NA B #10AWG THWN-2 PVC, EMT OR FLEX IN ATTIC 1"(1)#6AWG THWN-2 GND C (3)THWN-2 PVC, EMT OR FLEX IN ATTIC 1"(1)#6AWG THWN-2 GND D (1)#6AWG BARE GROUND NA NA (3) (6) #6AWG ENPHASE IQ CABLE MAXIMUM DISTANCE OF DTU FROM INVERTER SHOULD NOT EXCEED - 656FT NAME : GREG MARTIN LICENSE NO: 25250 SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-7.0 ELECTRICAL CALCULATION HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC 13.79 A 37.07 V 12.9 A 31.01 V HYPERION HY-DH108P8 400B TEMPERATURE DETAILS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%) -26° 32° CONDUCTOR AMPACITY BEFORE COMBINER PANEL: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC CIRCUIT CONDUCTOR SIZE TEMP. CORRECTION PER TABLE CIRCUIT CONDUCTOR AMPACITY NEC CODES 310.15(B)(2)(a) 310.15(B)(3)(a) 310.15(B)(16) - - 32° 0.96 6 0.8 10 AWG 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY 1.25 X MAX OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC 690.8(A&B) NEC TABLE 310.15(B)(2)(a) 310.15(B)(16) 310.15(B)(3)(a) 26.88A 15.38A CONDUCTOR AMPACITY AFTER COMBINER PANEL: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION CIRCUIT CONDUCTOR SIZE TEMP. CORRECTION PER TABLE CIRCUIT CONDUCTOR AMPACITY NEC CODES 310.15(B)(2)(a) 310.15(B)(3)(a) 310.15(B)(16) - - 65A 6 AWG 1 3 0.96 32° 1.25 X (TOTAL NUMBER OF INVERTERS X INVERTER MAX CONTINUOUS OUTPUT CURRENT) REQUIRED CIRCUIT CONDUCTOR AMPACITY DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC 690.8(A&B) NEC TABLE 310.15(B)(2)(a) 310.15(B)(16) 310.15(B)(3)(a) SELECTED OCPD NEC 240.6(A) 46.13A 62.4A 50A ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE INVERTER SPECIFICATIONS MANUFACTURER MODEL NO. MAX DC INPUT VOLTAGE MAX OUTPUT POWER PEAK OUTPUT POWER NOMINAL AC OUTPUT VOLTAGE NOMINAL AC OUTPUT CURRENT 600 VA 590 VA 60 V HM-600NT HOYMILES 2-IN-1 MICROINVERTER 240 V 2.46 A THIS SYSTEM IS EQUIPPED WITH RAPIDSHUTDOWN ROOFTOP INVERTERS WILLDE-ENERGISE AT SERVICE PANEL OUTAGE NOTICE SOLAR AC DISCONNECT LABELS AC COMBINER LABELS SERVICE PANEL LABEL TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN THIS IS MAIN 2 OF 2 WITH MAIN 1 OF 2 LOCATED INSIDE WARNING AC COMBINER AND DATA AQUISITION. DO NOT ADD LOADS. DO NOT TOUCH TERMINALS.LINE AND LOAD SIDE MAY BE ENERGIZEDIN OPEN POSITION. NOTICE NOTICE MAX CURRENT: 46.13A MAX FUSE: 50A AC VOLTAGE = 240V THIS IS MAIN 1 OF 2 WITH MAIN 2 OF 2 LOCATED ADJACENT THIS SERVICE IS ALSO SERVED BY A PV SYSTEM WITH RAPID SHUTDOWN. INVERTERS LOCATED ON ROOF AUTO DE-ENERGISE WHEN SOLAR SERVICE MAIN IS IN OPEN POSITION.THE DC CONDUCTORS OF THE PV SYSTEM ARE UNGROUNDED AND MAY BE ENEGIZED.IF BACKFEED BREAKER PRESENT DO NOT RELOCATE THIS OVERCURRENT DEVICE. DO NOT DISCONNECT UNDER LOAD DUAL POWER SOURCES. SECOND SOURCE IS PV SYSTEM !WARNING! DUAL POWER SUPPLY. SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM THIS SERVICE PANEL IS ENERGIZED FROM MORE THAN ONE SOURCE.ONLY AUTHORIZED PERSON WHO ARE FAMILIAR WITH THIS SYSTEM SHOULD ATTEMPT TO DO SERVICE WORK ON IT. !WARNING! !WARNING!WARNING CAUTION !WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD UTILITY AC DISCONNECT PV AC DISCONNECT NOTICE RAPID SHUTDOWN DISCONNECT SWITCH !WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ELECTRIC SHOCK HAZARD 2137 ROUTE 35 HOLMDEL, NJ 07733 TEL: (732) 979-2400 www.suntuity.com DUAL POWER SOURCE WARNING PHOTOVOLTAIC AC SOURCE CAUTION BI-DIRECTIONAL METER PHOTOVOLTAIC SYSTEM CONNECTED UTILITY METER LABELS CONDUIT LABEL DIRECTORY LABEL AS PER NEC 705.10NPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: MULTIPLE SOURCES OF POWER JBPM AC (N) MAIN SOLAR FUSED AC DISCONNECT (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (OUTSIDE) (N) SOLAR MODULES (N) AC DISTRIBUTION PANEL U DP MSP (N) PRODUCTION METER (N) NEMA 3R RATED TRANSITION BOX NAME : GREG MARTIN LICENSE NO: 25250 SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEJO WANNER/JIM E PERRY/KELLEY C PERRY18998 IBARRA TRAILLAKEVILLE MN 55044(Lat, Long: 44.674392, -93.247959)PV-8.0 LABELS HARSH JEEVAN 07-21-20232137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401 warranty for materials and workmanship warranty for extra linear power output 12Years 30Years ©Copyright 2023 HYPERION HY-DH108P8B-US-V1.7 IEC61215 / IEC61730 / UL61730IEC61701 / IEC62716 / IEC60068 ISO9001 info@hyperion-usa.com American Hyperion Solar LLC. 2880 Zanker Road, Suite 203, San Jose, CA 95134 395-415W MADE IN THAILAND HY-DH108P8B 108 HALF-CELL BIFACIAL MODULE High Conversion Efficiency Module efficiency up to 21.3%through advanced cell technology and manufacturing process Excellent Weak Light Performance More power output in weak light condition such as cloudy days,morning and sunset Extended Mechanical Performance Module certified to withstand extreme wind (2400 Pa and snow loading (5400 Pa Pa Quality Guarantee High module quality ensureslong-term reliability 98% 97% 84.95% 80.2% +3.25% +5.75%+7.00% 1 5 10 15 302025 +4.50% Conventional Module Hyperion Performance +2.00% Warranty partner HY-DH108P8B-395/415 1086±2 (42.76±0.08)30±1(1.18±0.04)860±1 (33.86±0.04)1360±1 (53.54±0.04)1722±2 (67.80±0.08)1134±2 (44.65±0.08) 33 (1.30)30 (1.18)A B AA-A Frame Section B Installation Hole9 (0,35)14 (0.55) Unit: mm (inch) BLACK DH108P8B Solar Cell No. of Cells Dimensions Weight Junction Box Output Cables Connector Back Cover Operating Temperature Max. System Voltage Max. Fuse Rating Frontside Max. Loading Bifaciality Fire Resistance DC 1500V (IEC/UL) Backside Max. Loading -40°C ~ +85°C(-40°F ~ +185°F) 30A 5400Pa (112lb/ft²) 2400Pa (50lb/ft²) 70%±10% IEC Class A, UL Type 29 395 30.84 12.81 36.98 13.70 20.2% Front Cover ©Copyright 2023 HYPERION HY-DH108P8B-US-V1.7www.hyperion-solar.com 310.2 29.82 10.40 35.39 11.25 306.4 29.60 10.35 35.31 11.19 302.5 29.41 10.29 35.15 11.13 298.8 29.25 10.22 35.07 11.05 42 ± 2 °C -0.35%/°C -0.27%/°C 0.05%/°C 45 ± 2 °C 405 400 31.21 12.98 37.23 13.87 410 31.45 13.04 37.32 13.95 21.0% 31.01 12.90 37.07 13.79 20.7% 20.5% Current-Voltage & Power-Voltage Curve (410W) 0 ~ +5 2.0mm(0.079in.) semi-tempered AR glass Mechanical Parameters Engineering Drawing Mono PERC 182mm 108 (6 × 18) 1722 × 1134 × 30mm (67.80 × 44.65 × 1.18in.) 23.8kg (52.47lbs) IP68 rated (3 bypass diodes) 4mm² (IEC),12 AWG(UL)(-/+)1200mm (47.24in.) or customized QC4.10 or similar 2.0mm(0.079in.) semi-tempered glass Container 36 pcs/Pallet, 792 pcs/40’HC Operating Parameters Electrical Characteristics - STC Maximum Power at STC (Pmax/W) Power Tolerance (W) Optimum Operating Voltage (Vmp/V) Optimum Operating Current (Imp/A) Open Circuit Voltage (Voc/V) Short Circuit Current (Isc/A) Module Efficiency Electrical Characteristics - NMOT Maximum Power at NMOT (Pmax/W) Optimum Operating Voltage (Vmp/V) Optimum Operating Current (Imp/A) Open Circuit Voltage (Voc/V) Short Circuit Current (Isc/A) Temperature Characteristics Nominal Module Operating Temperature Nominal Cell Operating Temperature Temperature Coefficient of Pmax Temperature Coefficient of Voc Temperature Coefficient of Isc Rearside Power Gain Maximum Power (Pmax/W) Irradiance 800 W/m², ambient temperature 20 °C, AM1.5, wind speed1m/s. Irradiance 1000 W/m², ambient temperature 25 °C, AM1.5. Rearside Power Gain (Reference to 415WFront) Optimum Operating Voltage (Vmp/V) Optimum Operating Current (Imp/A) Open Circuit Voltage (Voc/V) Short Circuit Current (Isc/A) Module Efficiency 5% 436 31.61 13.79 37.45 14.72 22.3% 15% 477 31.71 15.05 37.55 16.08 24.4% 25% 519 31.71 16.36 37.55 17.48 26.6% 415 31.61 13.13 37.45 14.02 21.3% 313.9 29.98 35.51 11.31 10.47 Open Energy For All Features Description Hoymiles 2-in-1 microinverter can connect up to 2 panels at once and maximize the PV production of your installation. With a maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and can meet the requirements of IEEE 1547, UL 1741 and CA Rule21. Microinverter Datasheet HM-600NT HM-700NT HM-800NT Region: North America V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown 05 04 External antenna for stronger communication with DTU High reliability: NEMA 6 (IP67) enclosure, 6000 V surge protection Model HM-600NT HM-700NT HM-800NT Input Data (DC) Commonly used module power (W)240 to 405+280 to 470+320 to 540+ Maximum input voltage (V)60 MPPT voltage range (V)16-60 Start-up voltage (V)22 Maximum input current (A)2 × 11.5 2 × 11.5 2 × 12.5 Maximum input short circuit current (A)2 × 15 Number of MPPTs 2 Number of inputs per MPPT 1 Output Data (AC) Peak output power (VA) 600 700 800 Maximum continuous output power (VA)590 696 766 Maximum continuous output current (A)2.46 2.84 2.90 3.35 3.19 3.68 Nominal output voltage/range (V)1 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)1 60/55-65 Power factor (adjustable)> 0.99 default 0.8 leading … 0.8 lagging Total harmonic distortion < 3% Maximum units per 10AWG branch2 9 8 8 7 7 6 Maximum units per 12AWG branch2 6 5 5 4 5 4 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C)-40 to +65 Dimensions (W × H × D mm)250 × 170 × 28 Weight (kg)2.6 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection – No fans Features Communication 2.4GHz Proprietary RF (Nordic) Type of isolation Galvanically Isolated HF Transformer Monitoring S-Miles Cloud3 Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac),CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems Technical Specifications © 2021 Hoymiles Power Electronics Inc. All rights reserved. *1 Nominal voltage/frequency range can vary depending on local requirements.*2 Refer to local requirements for exact number of microinverters per branch.*3 Hoymiles Monitoring System. Open Energy For All Features Description Hoymiles gateway DTU-Pro is a data transfer unit which collects information and data of PV microinverter using 2.4G wireless solution and sends them to S-Miles Cloud, Hoymiles monitoUing 6yVtem XVing diࢆeUent commXnication optionV such as Ethernet, Wi-Fi, GPRS or 4G. With DTU-Pro, users can easily read module-level data and alaUmV Ueali]e Uemote opeUation and maintenance oI P9 system at any time, from anywhere on S-Miles Cloud. Data Transfer Unit Datasheet DTU-Pro Region: Global V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Reliable and Flexible • Stable communication with HM, MI series of microinverter • More communication options with S-Miles Cloud, using Ethernet, Wi-Fi, GPRS or 4G • Support of RS485, Ethernet to communicate with peripherals Simple and Efficient O&M • Module-level monitoring and data storage • Local configuration with S-Miles Toolkit • Support remote O&M including remote upgrading, parameter setting Smart • Smart zero export control and power export limiting • PV generation and load consumption monitoring Model DTU-Pro (Wi-Fi Version)DTU-Pro (GPRS Version)DTU-Pro (4G Version) Communication to Microinverter Signal *+] PUopUietaUy 5) NoUdic Ma[imXm diVtance open Vpace200 m MonitoUing data limit IUom VolaU panelV 991 Communication to S-Miles Cloud Ethernet 5- MEpV Wireless2 Wi-Fi: 802.11b/g/n 2G: GSM/GPRS 4G: TDD-LTE, FDD-LTE 3G: SCDMA 2G: GSM/GPRS 6ample Uate Per 15 minutes Communication to Peripherals RS485 C2M EpV ModEXV5T8 Ethernet RJ45 × 1, Modbus-TCP '5M )oU $8N= onlyRJ45 × 1, DRM0/5/6/7/8 Interaction LED /E' ,ndicatoU ȁ 58N CloXd M, $/M APP S-Miles Toolkit Power Supply (Adapter) Type E[teUnal adapteU $dapteU inpXt YoltageIUeTXency 100 to 240 V AC / 50 or 60 Hz $dapteU oXtpXt YoltagecXUUent 5V/2A PoweU conVXmption Typ : Ma[ :Typ : Ma[ : Mechanical Data $mEient tempeUatXUe -20 to 55 'imenVionV : + ' mm withoXt antennaV :eight kg0.20 Installation method :all moXnting 'eVktop moXnting Environmental rating Indoor-IP20 Compliance CeUtiࢉcateV CE, FCC, IC, RCM, Anatel Microinverter Compatibility Microinverter model HM series, MI series Technical Specifications © 2021 Hoymiles Power Electronics Inc. All rights reserved. ThiV dependV on the inVtallation enYiUonment PleaVe UeIeU to XVeU manXal IoU moUe detailV*2 Extended antenna is recommended if the DTU is installed inside a metal box or under a metal/concrete roof. FRAME MLPE MOUNT SS 0.8 2.02 2.02 1) FRAME MLPE MOUNT ASSEMBLY 1 ITEM NO.DESCRIPTION 1 FRAME MLPE MOUNT ASSEMBLY PART NUMBER DESCRIPTION 4011012 FRAME MLPE MOUNT SS Material Stainless Steel Finish Mill REV.- CS1 VERSION: v2.8REVISION DATE: 03/2/22 INSTALLATION GUIDEINSTALLATION GUIDE RATINGSPAGE 05 TORQUE SPECIFICATIONS *Class A System fire rating with Type 1 & 2 PV modules. Any module-to-roof gap is permitted, with no skirt required. UL 2703 MARKING EXAMPLE: System components should be periodically re-inspected for loose components, loose fasteners, and corrosion such that if found, the affected components are to be immediately replaced. RATINGS Fire Ratings*Class A System Fire Rating Max System Voltage 1500V Max Fuse Rating 40A Certification Conforms to UL STD 2703 Markings Product listing label is located on RockIt Mount Roof Pitch 2:12 - 12:12 UL 2703 Allowable Design Load Rating 30 psf downward, 30 psf upward and 20 psf lateral Max Module Size 24 sq. ft. Maximum Cantilever 1/3 of span Maximum Span 6 ft Landscape, 4 ft Portrait Multiple use Rated Components (Position Independent)RockIt Mount, RockIt Coupling & MLPE Module Mount Component Torque (in-lb)Notes Lag Screws N/A Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. Mount 200 Coupling 200 Steel Slide Screw N/A Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. MLPE Module Mount 144 Ground Lug N/A Refer to specific ground lug manufacturer’s installation manual RockIt Pedestal Screw 150 ROCKIT SYSTEM MFG ID CODE: SSS-QQ-YYYY Conforms to UL STD 2703 TM XXXXXXX VERSION: v2.8REVISION DATE: 03/2/22 INSTALLATION GUIDEINSTALLATION GUIDE GROUNDINGPAGE 20 THERMAL EXPANSION & BONDING • A thermal expansion gap is required per each continuous 40’ length of modules. • Omit a coupling and leave a 2” gap in the RockIt array skirt and also between the modules at that point. • Bonding across the thermal gap should be accomplished with an approved ground lug for each array and an equipment grounding conductor. BONDING PATH & ASSEMBLY • RockIt mount bonds N-S rows of modules. • RockIt coupling bonds E-W rows of modules. • RockIt array skirt is bonded to the array via the RockIt mount. • One approved ground lug is required per continuous PV array. BONDING AND GROUNDING Bond Path Grounding Lug Equipment GroundingConductor (EGC) RockIt Coupling RockIt Mount RockIt Array Skirt Bond Path Grounding Lug Equipment GroundingConductor (EGC) RockIt Coupling RockIt Mount RockIt Array Skirt VERSION: v2.8REVISION DATE: 03/2/22 INSTALLATION GUIDEINSTALLATION GUIDE GROUNDINGPAGE 21 NECESSARY COMPONENTS One of the following grounding lugs (or any UL 2703 Compliant ground Lug): • Burndy CL50-1TN Ground Lug (UL2703 - E3514343 / UL 467 - E9999) • ILSCO SGB-4 Ground Lug (UL2703 - E354420/ UL 467 - E34440) • ILSCO GBL-4DBT (UL2703 - E354420 / UL 467 - E34440) • ILSCO GBL-4DBTH (UL2703 - E354420 / UL 467 - E34440) • ILSCO GBL-4SS (UL2703 - E354420 / UL 467 - E34440) INSTALLATION • Insert the flange bolt into the module ground hole. Place Star Washer over bolt. Place ground lug over the bolt and Star Washer, and turn to desired orientation. • Install Flange Nut. • Tighten Flange Nut/Bolt. • Place wire in Ground Lug channel and tighten set screw to complete assembly. BONDING AND GROUNDING Above: Optional Location for grounding lug on last row upslope of array *Equipment grounding wire should be sized in accordance with the National Electrical Code, NFPA70 and a minimum of 1/4” clearance is required between bare copper wires and aluminum components. INTRODUCING ROCKIT SMART SLIDE! ROCKIT SMART SLIDE • Eliminates the need to pry up shingle courses and install a metal flashing • Multiple opportunities to find the rafter • Eliminates the need to drill pilot holes • No need for additional material when architectural shingles are not level • Longer 6.75” slide avoids overlaps in shingle courses • Integrated flashing utilizes UltraGrip Technology™ to create a watertight seal Introducing EcoFasten’s patent pending RockIt Smart Slide, our simple solution for quickly installing the popular RockIt rail-less racking system to composition shingle roofs. Features & Benefits Required Components: ECOFASTENSOLAR.COM Part Number:Description: 2011024 RI SMART SLIDE BLK 6.75” 2011025 RI SMART SCRW #12X3” W/BW ROCKIT SMART SLIDE 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 1-877-859-3947 _ INFO#ECOFASTENSOLAR.COM VERSION 1.2Integrated UltraGrip Technology™ Pre-installed sealing pads are compatible with all composition shingle roofs and can be installed in ambient temperatures as low as 5 degrees. The compression achieved when fastened to the roof creates a super strong watertight seal. In most cases, Smart Slide can be installed to the roof without the need for sealant. A layer of flexible foam provides cushioning, which allows the super- sticky waterproofing sealant to embed deep into the granules of the shingle as well as to flexibly conform over the steps found on architectural-style shingles. Testing & Documentation • UL441 Rain Report • TAS 100 (A)-95 Wind and Wind Driven Rain Resistance • Mechanical Load Test/Structural Capacity Certification • Florida Product Approval • RockIt Installation Manual • RockIt CutSheets A layer of flexible foam pushes the sealant deep into the shingle granules and around shingle steps RockIt Smart Slide can be installed on top of architectural shingles steps © 2018 Schneider ElectricAll Rights Reserved 3-3 schneider-electric.us Light Duty Safety Switches Class 3130 / Refer to Catalog 3100CT1602 Light Duty—Visible Blades 10 kA Short Circuit Current Rating L221N The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces, and garages. The light duty safety switch has visible blades and a ground lug as standard features. Table 3.1: Fusible System Amperes Fuse NEMAType 1 IndoorCat. No. Horsepower Ratings 120 Vac 240 Vac Std. Max.Std. Max. 1Ø 1Ø 1Ø 1Ø 2 Wire (1 Blades and Fuseholders, 1 Neutral)—120 Vac 30 Plug L111N — ——— 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac 30 Plug Cart L211N L221N 1/2 1/2 2 2 1-1/2 1-1/2 3 3 General Duty—Up To 100 kA Short Circuit Current Rating General duty safety switches are designed for residential and commercial applications where durability and economy are prime considerations. Typical loads are lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factory or field-installed neutral assembly or a field-installed service grounding kit, (see page 3-5) as applicable. General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1. 240 Volt—Single Throw Fusible Switches D223N Table 3.2: Fusible System Amperes Fuse NEMA Type 1 Indoor NEMAType 3R[1]Rainproof Class RFuse Kits[2] Horsepower Ratings Std. (Fast ActingOne-Time Fuses) Max. (DualElementTime-DelayFuses) Cat. No. Cat. No. Cat. No. 1Ø 3Ø 1Ø 3Ø 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac 30 Plug Use Light Duty Device for this Application (see above) — — — — 30 Cart. Use three-wire devices for thisapplication.— — — — 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum 30 Plug D211N D211NRB — 1-1/2 — 3 — 30 Cart.D221N D221NRB DRK30 1-1/2 3[3] 3 7-1/2 [3] 60 Cart.D222N D222NRB RFK03H 3 7-1/2[3]10 15[3] 100 Cart.D223N D223NRB RFK10 7-1/2 15[3]15 30[3] 200 Cart.D224N [4]D224NRB[4]HRK1020 15 25[3]—60[3] 400 Cart.D225N D225NR DRK40 — — — — 600 [5]Cart.D226N D226NR DRK600 — — — — 4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum 30 Cart.D321N D321NRB DRK30 1-1/2 3 3 7-1/ 2 60 Cart.D322N D322NRB RFK03H 3 7-1/2[6]10 15[6] 100 Cart.D323N D323NRB RFK10 7-1/2 15[6]15 30[6] 200 Cart.D324N[4]D324NRB[4]HRK1020 15 25[6]—60[6] 400 Cart.D325N D325NR DRK40 — 50 — 125 400 [7]Class T D325NT D325NTR — — 50 — — 600 [5]Cart.D326N D326NR DRK600 — 75 — 150 600 [7]Class T D326NT D326NTR — — 75 — — 800 [7]Class T T327N T327NR — — 100 — —3SAFETY SWITCHES [1]Bolt-on hubs —Refer to Rainproof Bolt-On Hubs,Table 1.27, page 3-14. [2]When properly installed, the Class R Fuse Kit rejects all but Class R fuses. [3]For corner grounded delta systems only. Use switching poles for ungrounded conductors. See data bulletin 2700DB0202 for additional information. [4]For 200% neutral, order (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI. [5]Order Class J Fuse Kit GDJK600 if using Class J fuses. [6]If corner grounded delta, use outer switching poles for ungrounded conductors. [7]D325NT, D325NTR, D326NT, D326NTR, T327N and T327NR accept only 300Vac Class T fuses. 08/06/2018 3-4 © 2018 Schneider ElectricAll Rights Reserved General Duty Safety Switches General Duty—Up to 100 kA Short Circuit Current Rating schneider-electric.usClass3130/ Refer to Catalog 3100CT1602 240 Volt—Single Throw Non-Fusible Switches Table 3.3: Non-Fusible System Amperes NEMAType 1 Indoor NEMAType 3RRainproof[8]Horsepower Ratings(Max.) Cat. No.Cat. No.1Ø 3Ø 2 Wire (2 Blades)—240 Vac Maximum 30 —DU221RB 3 — 60 —DU222RB 10 — 60 QO260NATS [9] [10]QO200TR [9] [10] [11]10 — 100 QO2000NS [9] [10]QO2000NRB [9] [11]20 — 200 Use 3P Switch Use 3P Switch —— 400 Use 3P Switch Use 3P Switch —— 600 Use 3P Switch Use 3P Switch —— 3 Wire (3 Blades)—240 Vac Maximum 30 DU321 DU321RB 3 7-1/2 60 DU322 DU322RB 10 15 100 DU323 [12]DU323RB [12]15 40 200 DU324 [13]DU324RB [13]15 60 400 DU325 —— 125 600 DU326 [14]—— 150 UL Listed Maximum Short Circuit Current Ratings — AC Only Table 3.4: Fusible Safety Switch Short Circuit Current Rating Fuse Class UL Listed Short Circuit Rating Plug 10 kA H, K 10 kA J [15], R 100 kA T [16]100 kA Non-Fusible Safety Switches Systems equal or less than 10 kAIR SCCR —Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with a non-fusible safety switch. Systems above 10 kAIR SCCR—The UL Listed short circuit current rating for Square D non-fusible switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.5: Non-Fusible Safety Switch Short Circuit Current Rating Fuse Class or Circuit Breaker Type[17]UL Listed Short Circuit Rating Any Brand Circuit Breaker 10 kA H or J PowerPact Circuit Breaker Up to 65 kA [18] H, K 10 kA J, R 100 kA [19] T 100 kA [20]3SAFETY SWITCHES [8]Bolt-on hubs—Refer toHubs, page 3-14. [9]Enclosed molded case switch—Refer to Section 1. [10]Includes factory-installed grounding kit. [11]Not service entrance rated—Refer to Table 3.34 for more information. [12]If a neutral assembly is required, order and field install SN0610. [13]If a neutral assembly is required, order and field install a SN20A Neutral Assembly Kit. For a 200% neutral application, order and field install (2) SN20A Neutral Assembly Kits and (1) SN20NI Neutral Jumper Kit. [14]If a neutral assembly is required, order and field install D600SN. [15]Only applicable to 200 A - 600 A except D325NT, D325NTR, D326NTand D326NTR. [16]Only applicable to D325NT, D325NTR, D326NT, D326NTR, T327N and T327NR. [17]Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. [18]Only applicable to DU324 and DU324RB. HD, JD = 25 kA maximum. [19]SCCR = 50 kA, applicable to DU222RB, DU322 and DU322RB. [20]Only applicable to DU323, DU323RB, DU325 and DU326. 08/06/2018 ezsolarproducts.com | info@ezsolarproducts.com | 385.202.4150 MORE SPACE FAST INSTALLCOST EFFECTIVE 5019942 XL JB-1.XL THE ULTIMATE ROOFTOP JUNCTION BOX JUST GOT BIGGER... AND BETTER!INTRODUCING JB-1.XL JB-1.XLSpecification SheetPV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: 120 Amps • Allowable Wire: 14 AWG – 6 AWG • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 – 12:12 • Max Side Wall Fitting Size: 1” • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.XL: UL1741 - Approved wire connectors: must conform to UL1741 • System Marking: Interek Symbol and File #5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. A. System Specifications and Ratings Phone: 385-202-4150 | www.ezsolarproducts.com