Loading...
HomeMy WebLinkAboutLA217624 - 17839 Hamburg Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND 200 AMP SERVICEGARAGE LEFTSLAB ON GRADECATEGORY ONESUMMERS CREEK VILLASLOT 13, BLOCK 7 2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDLAKEVILLE, 55044INVENTORY HOMESIDEWALKGARAGE SLABHOUSE SLABFLATWORK SQUARE FOOTAGE1,595 SF540 SFNOTED OTHERWISE ON PLANS.ALL HEADERS ARE (2) 2x10 TYPICAL UNLESSWITH DIMENSIONS TO BE VERIFED SHALLTRUSS DESIGN BY MFG. TRUSSES NOTEDHEADERS:TRUSSES:BE FIELD MEASURED BY TRUSS SUPPLIERHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"TOTAL1,689 SF-FIRST FLOORGARAGEFLOOR AREA1,689 SFFINISHED-567 SFUNFINISHED-2018 BUILDING CODE2020 ENERGY CODE185 SF - ELEV B - PORCH17839 HAMBURG AVENUE2ND. ADDITIONFRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETEFOUNDATION INSULATIONSLAB ON GRADEYOUNGFIELD SERIESELEVATION - BSIDEWALK 185 SFGarage6'-6"30"Bedroom #2(2) 36x60 MULLED6'-6"36"EntryA13'-0"3'-6"6'-1014"3'-0"2-2x106'-0"21'-714"(2) 2x10666'-0"66Porch2'-6"2'-0"13'-0"4'-0"8'-714"1x6 LP TRIM1x6 LP TRIM1'-2"1'-4"ALUMINUM SOFFITCEDARMILL TEXTURELP PANEL WITH3/8" BEAD VULKEM CAULKINGALL 4 SIDES& BACK OF COLUMN1x3 LP TRIM ON FRONT1x2 ON EACH SIDESCALE: 1/2" = 1'-0"COLUMN #12 - CONCRETE PORCH6" CONC. WALLCONCRETE PORCHT.O. CONC.T.O. FTG.T.O. WALLELEV. 102'-10"FIREPLACE FROM GREAT ROOMSCALE: 1/4" = 1'-0"GreatRoomCARPET9'-118"1'-2"1'-2"3'-6"SHEETROCKLINE OFLINE OFFIREPLACESHEETROCK4'-81 4"TILE1'-5"1'-7"6"1'-1"6"2"1'-11"LINE OFCOLUMN3'-21 4"10"10"7'-6"6'-778"6'-778"21'-512"7'-358"7'-212"6'-1138"GAS FIREPLACE1'-5"7'-6"NO HEARTHLINE OFSHEETROCKABOVE FIREPLACE1'-7" 1'-1" 1'-11"LINE OF COLUMNLINE OF MANTLE3'-6"03-14-22A-0COVER SHEETPORTLAND 3 BEDROOM SLAB ON GRADE GARAGE RIGHT LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode09/07/2023dmathews SCALE: 1/4" = 1'-0"A-11121'-6"81289'-11 8"T.O.. 6" WALLTOP OF PLATE5-1/2" TRIM AROUNDFRONT DOOR & WINDOWS6" FREIZE BOARDBOTH GARAGE PIERS12" RAKES @ FRONT ELEVATIONFASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWNON ATTACHED DETAILS.FOR BRACED WALL REQUIREMENTSUSE 1/2" OSB SHEATHING1'-6"HARDIE LAP21'-0"HARDIE ON ALL 4 SIDESELEV. 103'-6"ELEV. 112'-7-1/8"20'-0"8'-0"16'-0"FRONT ELEVATION - BTOP OF FOOTINGELEV. 100'-0"9'-10"SHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVES)3'-10"18" EYEBROW ROOFCONCRETE SLAB6:12HARDIE SHAKES3'-0"STONE93.20 SFFRONT26.97%%HARDIE LAP66.06 SF19.12%SHAKES186.20 SF53.91%345.46 SFSIDES & REAR ARE 100%HARDIE LAP - 7" EXPOSURE.TOTALMATERIALS18x30 FIXED 2" SILL STOCKADDRESSLAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC62767003-14-22ELEVATIONSPORTLAND A-1BSLAB ON GRADE 3 BEDROOM A-2RIGHT ELEVATION2SCALE: 1/8" = 1'-0"A-21REAR ELEVATIONSCALE: 1/8" = 1'-0"8121'-6"T.O. FTG.ELEV. 103'-6"T.O. 6" WALLEL. 100'-0"TOP OF PLATEELEV. 112'-7-1/8"HARDIE ON ALL 4 SIDES40'-0"9'-11 8"1'-6"9'-118"1'-6"9'-118"T.O. FTG.ELEV. 103'-6"T.O. 6" WALLEL. 100'-0"TOP OF PLATEELEV. 112'-7-1/8"1'-0"8:12HARDIE ON ALL 4 SIDES55'-0"SHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVES)8:129'-11 8"4'-0"1'-0"8:12SCALE: 1/8" = 1'-0"LEFT ELEVATION3A-2T.O. FTG.ELEV. 103'-6"T.O. 6" WALLEL. 100'-0"TOP OF PLATEELEV. 112'-7-1/8"1'-0"8:12HARDIE ON ALL 4 SIDES59'-0"2'-0"8:122'-0"3'-0"8:12SCALE: 1/8" = 1'-0"ROOF PLAN4A-212 ROOF VENTS40'-0"55'-0"8:1259'-0"1'-6"8:128:12VAULT4:12VAULT4:121'-0"1'-6"8:128:12SHINGLES66 6 66:126:128:1266 66 PORTLAND03-14-22ELEVATIONSA-2B3 BEDROOM SLAB ON GRADE LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670ELEVATION - B T.O. 6" WALLT.O. FTG.EL. 100'-0"T.O. SLABUnexcavated4" CONC. SLABVARIEST.O. 6" WALLT.O. FTG.EL. 100'-0"T.O. FTG.T.O. 6" CURBT.O. FTG.T.O. 6" WALLT.O. 6" CURBT.O. 6" WALLT.O. FTG.EL. 100'-0"2" BRICK LEDGEELEV. 102'-10"1FOUNDATION PLAN - ELEV. BSCALE: 3/16" = 1'-0"A-3(2) 1-3/4"x11 7/8" LSL2'-412"16'-3" M.O.20'-0"59'-0" 27'-0" 6'-0" 55'-0"40'-0"6'-0"6'-0"21'-0"8"Unexcavated3-1/2" CONC. SLABT.O. 6" WALLT.O. FTG.EL. 100'-0"6"24" - #4 REBAR EMBEDDED3" INTO CONCRETE WALLEVERY 6'-0" O.C.2A-5WDBath11'-6"15'-112"20'-134"7'-638"4'-4"1'-9"19'-03 4"Laundry2A-33A-3WASTE CONDU I T TO CENTER I SL AND 8"8"2" BRICK LEDGET.O. 6" CURB2" BRICK LEDGET.O. 6" CURB1A-53A-5RADONPIPE10'-118"7'-3"MechRoomEL. 103'-6"EL. 100'-0"EL. 103'-6"EL. 100'-0"EL. 102'-10"EL. 103'-6"EL. 103'-6"EL. 103'-6"EL. 102'-10"EL. 103'-6"EL. 102'-10"EL. 103'-6"EL. 103'-6"2" BRICK LEDGEEL. 102'-10"EL. 102'-10"2" BRICK LEDGE3'-6"28"60x3428"Bath8"x16" CONCRETEFOOTINGS - TYPICAL5,000 LB. FOOTINGSTRENGTH MIX.8"x16" CONCRETEFOOTINGS - TYPICAL5,000 LB. FOOTINGSTRENGTH MIX.13'-0"T.O. 6" WALLT.O. FTG.EL. 100'-0"EL. 103'-6"Unexcavated3-1/2" CONC. SLAB6'-0" 2'-0" 61'-0" APPROX. LOCATIONOF ELEC PANELPROVIDE UFER GROUNDING ROD 4'-0" 6'-734" 7'-4" 13'-412"4'-734" 1'-41316"2'-6"2'-878"3'-1"1'-634"HOSEBIBHOSEBIBDW 10'-0"Unexcavated3-1/2" CONC. SLAB25'-9"T.O. WALLEL. 102'-10"2" BRICK LEDGEEL. 102'-10"14'-3"16" x 8" CONC. FTG'S5,000 LB. FOOTINGSTRENGTH MIXELEV. 100'-0"ELEV. 103'-6"TOP OF WALLTOP OF FTG.3'-6"2x6 TREATED BOTTOMPLATE OVER SILL SEALERBEFORE INSTALLING PLATE THEREMUST BE A LAYER OF MASTIC, SILL SEALER AND ANOTHER LAYERMASTIC. 6"2"3-1/2" CONCRETE SLAB 2x6 EXTERIOR WALLSR20 BATT INSULATION1/2" OSB SHEATHINGCONTINUOUS MASTIC24" -#4 REBAR - 3" EMBEDMENTINTO WALL @ 6-0" O.C.CONTINUOUS MASTIC6" POURED CONCRETE WALLSCALE: 3/4" = 1'-0"BUILDING SECTION @ HOUSEA-322" R-10 RIGIDFOAM INSULATION6 MIL POLY UNDER SLABEXTEND UP TO PLATE1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)ELEV. 100'-0"ELEV. 103'-6"TOP OF WALLTOP OF FTG.3'-6"2x4 TREATED BOTTOMPLATE OVER SILL SEALER8"4" CONCRETE SLAB 2x4 EXTERIOR WALLS1/2" OSB SHEATHINGSCALE: 3/4" = 1'-0"BUILDING SECTION @ GARAGEA-331/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)8" POURED CONCRETE WALL16" x 8" CONC. FTG'S5,000 LB. FOOTINGSTRENGTH MIX2" BRICK LEDGE2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDELEV. 103'-6"TOP OF WALL4" CONCRETE SLAB 2x6 WALL1/2" DRYWALLSCALE: 1/2" = 1'-0"PASSIVE RADON DETAILA-34CL10'-0" NTS10'-0" NTS3" PERFORATED PIPE6" CLEAR GRAVEL6"LAUNDRY WALL3" SOLID PIPETO ATMOSPHEREUFER GROUNDING RODONE GROUNDING ROD MUST BEPROVIDED. VERIFY SIDE OFGARAGE SIDE: PLACE ROD 4'-0"BACK FROM FRONT CORNER.HOUSE SIDE: PLACE ROD 6'-0"ELECTRICAL SERVICE.BACK FROM FRONT CORNER.UNLESS NOTED DIFFERENTPER BUYERS REQUESTPORTLAND03-14-22UPPER LEVEL PLANA-33 BEDROOM SLAB ON GRADE LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 2'-1"GreatRoomLVPGarage4" CONC. SLAB16'x8' O.H. DOOR(2) 11-7/8" LVL - CONT.SLOPE SLAB 2x6 STUD WALLS @ 16" O.C. W/ (R=21)FIBERGLASS BATT INSULATION 4 MILTYPICAL GARAGE WALL2x4 STUD WALLS @ 16" O.C. W/INSIDE AND 1/2" SHEATHING - EXT.POLY VAPOR BARRIER & 1/2" GYP. BD.1/2" SHEATHING - EXT.TYPICAL EXT. WALL2'-6"16'-0"59'-0"5/8" TYPE "X" GYP. BD. ON ALLWALLS ADJACENT TO HOUSE@ 24" O.C.PRE-ENGINEERED TRUSSESBOTTOM OF GARAGEDOOR SHOULD BESET 4" DOWN FROMTOP OF POURED WALLSTART SLAB AT TOPOF WALL AT BACK OFGARAGE27'-0"20'-6"17'-0" 35'-111 4"6'-6"30"Bedroom #2CARPET(2) 36x60 MULLED6'-6"36"EntryLVP7'-134"A6'-0" 11'-314"13'-0"CoveredPorchCONCRETEPrimaryBedroomCARPETWD4'-0"28"REF.GAS RANGE 2'-0"6'-0" 32'-0" ROD & SHELVES PrimaryW.I.C.CARPETLaundryVINYL24x42 S.H.KitchenLVP3'-6"B(2) 2x10A5'-312"4'-0"2-2X10 6'-1014"9'-0"BathVINYL26 SF (FLR)3'-0"7'-914" 19'-03 4"14'-11"36x60 (2) 2x102-2x1028"PantryLVP21'-512"2'-4"2'-434"32x604'-4"A3'-1"24x69ISLANDTOP SIZE 37x72OVERHANG 5'-1034"LINEN14'-534"30"18"Bedroom #3CARPET27'-0"(2)2x1032" MTL.DR. S.C.30"12'-1"2'-434" 12'-712"(3)30x72 MULLED40'-0"(2) 36x60 MULLEDA5'-812"12'-234"DiningLVP4' BI-FOLDROD & SHELVES4'-4"7'-712"7'-312"60x3428"11'-134"6'-734"7'-4"13'-412" ROD & SHELVES9'-434"5'-912"5'-334"6'-6"1'-614"4'-734"6'-0"19'-0"6'-10"4'-7"5'-534"4'-834"VAULT4:12VAULT4:12HATCHED AREASARE VAULTED27'-434"3'-1"6'-134"4'-4"2'-734" 8'-83 4"PrimaryBathVINYL37 SF (FLR)HallLVPMudRoomVINYL4'-0"2'-6"SOLID SOFFITAT PORCHROD & SHELVES9'-0"5'-0" BI-FOLD2'-6" 2'-114"8'-41 2" PANEL ACCESSATTIC22x30ATTIC STORAGE TRUSSESTEMP.2A-33A-31A-53A-555'-0"32"OUTLETSOFTENERMech. Room4" CONC. SLAB59 SFDRAINFLOORWATERHEATERFURN.(2) 2x10TRUSSES @ 24" O.C.PRE-ENGINEERED ROOF(2) 2x10FLATFRAMEOSB PLYWOODON CEILING OFMECH ROOM.4'-4"5'-0" BI-FOLD DWHOSEBIBHOSEBIBPORTAL FRAMEBALLOON FRAME THISWALL TO VAULT LINESOLIDWINDWASH 28"5'-934"6'-134"6'-0" x 8'-0" PATIO(2) 2x10SCDSSSSSSCDCD6'-0"6'-0" 6618'-0"1'-0"5'-0" 6'-0" 2'-0"2'-0"6 6PorchCONCRETE(2) 2X8 DROPPED(2) 2X8 DROPPED 36" VAN.60" VAN.2'-6"1'-0"1'-6"2'-0"21'-0"19'-0"SOLID SOFFITAT PORCHA-41FIRST FLOOR PLAN - ELEV. BSCALE: 1/4" = 1'-0"A-41634"FIB. BASE8'-0" C.T. WALLSFRAME WALL OUT25'-9"25'-9" x 10'-0"Screened Porch10'-0" (3) 7-1/4" LSL - CONT.SOLID SOFFIT5'-0"5'-0" (3) 7-1/4" LSL - CONT. 10'-0"GAS FIREPLACE7'-358"7'-212"6'-1138"2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"FINISHED ROOM SIZESMAIN BATH - VINYLGREAT ROOM - LVPKITCHEN/DINING/PANTRY-LVP42 SF295 SFMUD ROOM - VINYL44 SFPRIMARY BEDROOM - CARPET176 SF336 SFPRIMARY BATH - VINYL61 SFBEDROOM #2 - CARPET156 SFBEDROOM #3 - CARPET161 SFLAUNDRY - VINYL37 SFPRIMARY W.I.C. - CARPET61 SFENTRY/HALL/LINEN - LVP140 SFMECH. ROOM59 SFBE FIELD MEASURED BY TRUSS SUPPLIERTRUSS DESIGN BY MFG. TRUSSES NOTEDWITH DIMENSIONS TO BE VERIFED SHALLALL HEADERS ARE (2) 2x10 TYPICAL UNLESSNOTED OTHERWISE ON PLANS.HEADERS:TRUSSES:PORTLAND03-14-22FIRST FLOOR PLANA-B3 BEDROOM SLAB ON GRADE LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3.53.5PFHPFH3.3 SCALE: 1/4" = 1'-0"BUILDING SECTIONA-529'-11 8"ELEV. 100'-0"ELEV. 103'-6"TOP OF WALLTOP OF FTG.3'-6"TOP OF PLATE1/2" ANCHOR BOLTS @ 6'-0" O.C.PLATE(S) W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILL3-1/2" CONCRETE SLABELEV. 103'-6"T.O. 4" CURBELEV. 100'-0"T.O. FTG.ELEV. 112'-7-1/8"3'-6"OP OF PLATE812412GreatRoomPrimaryBedroomDiningV. 112'-7-1/8"3-1/2" CONCRETE SLABR-49 ATTIC INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.SCALE: 1/4" = 1'-0"BUILDING SECTIONA-519'-11 8"ELEV. 100'-0"ELEV. 103'-6"TOP OF WALLTOP OF FTG.3'-6"TOP OF PLATE1/2" ANCHOR BOLTS @ 6'-0" O.C.PLATE(S) W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILL4" CONCRETE SLABELEV. 103'-6"T.O. 4" CURBBOTTOM OF GARAGEDOOR SHOULD BESET 4" DOWN FROMTOP OF POURED WALLGarageELEV. 100'-0"T.O. FTG.DIAG. WIND BRACINGAS REQUIRED3-1/2" CONCRETE SLABTOP OF PLATE812ELEV. 111'-7-1/8"ELEV. 112'-7-1/8"Bedroom #2EntryR-49 ATTIC INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.4" BRICK LEDGE COLUMNS AT GARAGE ONLY3'-6"16" x 8" CONC. FTG'S5,000 LB. FOOTINGSTRENGTH MIXELEV. 100'-0"ELEV. 103'-6"TOP OF WALLTOP OF FTG.3'-6"2x6 TREATED BOTTOMPLATE OVER SILL SEALERBEFORE INSTALLING PLATE THEREMUST BE A LAYER OF MASTIC, SILL SEALER AND ANOTHER LAYERMASTIC. 3-1/2" CONCRETE SLAB 2x6 EXTERIOR WALLSR20 BATT INSULATION1/2" OSB SHEATHINGCONTINUOUS MASTIC24" -#4 REBAR - 3" EMBEDMENTINTO WALL @ 6-0" O.C.CONTINUOUS MASTICSCALE: 3/4" = 1'-0"BUILDING SECTION @ HOUSEA-531/2" SHEATHING FOREXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISEMIN. 6" ENERGY HEALTOP OF PLATEELEV. 112'-7-1/8"9'-11 8"4 MIL. POLY V.B.5/8" GYP. BD. OVERINSULATIONR=49 F.G.1'-6"8"VENTSOFFIT8126"2"6" POURED CONCRETE WALL2" R-10 RIDGIDFOAM INSULATION6 MIL POLY UNDER SLABEXTEND UP TO PLATE1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)SHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVESPORTLAND03-14-22SECTIONS & DETAILSA-53 BEDROOM SLAB ON GRADE LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 COPYRIGHT HANSON GROUP, LLC 2021©DescriptionDateRevisionOctober 18, 2021Project Number:Date:1.538S11Sheets: of1Youngfield Homes, Inc.22260 Dodd BoulevardLakeville, MN 55044Single Family Residence17849 Graphite LaneLakeville, MN3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.Print Name:Signed: License Number:10-18-21Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.Garrett Brunell52600S1FRAMING DETAILGARAGE FRONT PORTAL FRAME2NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.INTERIOR BEARING WALLINTERIOR NON-BEARING WALLTHIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.BRACED WALL CONNECTION(ROOF TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLEXTERIOR BEARING WALLINDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ON EXTERIORFACE IN ACCORDANCE w/ NOTE 2. PROVIDE INCREASED FASTENINGREQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TO BECONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)(MIN. LENGTH)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUM SHEATHING BOTHFACES WITH EITHER FASTENER OPTION LISTED IN NOTE 3, SPACED AT 4"O.C. PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWNBELOW.MAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY1S1REFERENCE PLANBRACEDWALL LINEBRACED WALL LINEBRACEDWALL LINEBRACED WALL LINE BRACED WALL LINE BRACED WALL LINE CONSTRUCTGARAGE PORTALFRAME AS SHOWNIN 2/S1(4-FT)(4-FT)(3.3-FT)(3.5-FT)(3.5-FT)(4-FT)(4-FT)(4-FT)(4-FT) (4-FT)SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.5.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.6.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).7.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.8.COVERED ENTRY PORCH IS CONSIDERED BY THE HANSON GROUP TO BE A NON-ESSENTIAL, PRIMARILY OPENSTRUCTURE AND NOT PART OF THE MAIN WIND FORCE RESISTING SYSTEM. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)REPRESENTSFIGURER602.10.8.2(3)ROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIP2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPOST-INSTALLED HOLDOWN OPTIONS3S1FRAMING DETAIL16'-3"±9'-118" ±FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x4/2x6 BEARING STUD & (1) 2x4/2x6FULL HEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROM CENTEROF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x4/2x6 BEARING STUDS MIN.PROVIDE 2x4/2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 3/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELSCONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)2'-412"±2'-412"±SIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORCONCRETEFOUNDATIONBELOW(4-FT) (4-FT)(4-FT)(4-FT)(4-FT) Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. License Number:1-1-23 46665Date: SCOPE OF DRAWINGS: THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2023. 2023 FOUNDATION GUIDE: DRAWING INDEX: SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE S15 COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 150 3.001 January 1, 2023 S0 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS SCOPE, INDEX, & CERTIFICATION Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 DRAWING USE GUIDELINES AND LIMITATIONS THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. LIMITATIONS 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST OR STRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED. 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. COLD WEATHER GUIDELINES: 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. MATERIALS CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM EQUIVALENT REBAR TABLE FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 151 3.001 January 1, 2023 S1 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS DRAWING LIMITATIONS & MATERIALS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GENERAL NOTES 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT AND FROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2" OFCENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. 20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOIL PRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THE RESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGN FOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW AND CONSENT OF THE HANSON GROUP. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 152 3.001 January 1, 2023 S2 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS GENERAL NOTES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MINDETAIL B 3" MIN TYPCONCRETE STRIP FOOTING 11B DETAIL A 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLYELEVATION STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 153 3.001 January 1, 2023 S3 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEP FOOTING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com & T G Y U % Q P E T G V G + P E 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 154 3.001 January 1, 2023 S4 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WALKOUT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 155 3.001 January 1, 2023 S5 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS LOOKOUT/KNEE WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com & T G Y U % Q P E T G V G + P E 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4 x 5'-0" HOOKS @ 24" O.C. EMBEDDED IN FOUNDATION WALL & CAST INTO SLAB (MAY REDUCE 2'-0" LEG LENGTH & DRILL IN & EPOXY 8" MIN. INTO FOUNDATION WALL) 3'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT)2'-0" COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 156 3.001 January 1, 2023 S6 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS UNBALANCED FOUNDATION DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING PER CODE OR BY BUILDING DESIGNER, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN BELOW 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE CLEAR HEIGHT OF 8'-0" OR LESS (2)#4xCONT. HORIZONTAL BARS CLEAR HEIGHT OF 8'-0" OR MORE (3)#4xCONT. HORIZONTAL BARS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) GENERAL STRIP FOOTING SIZE GUIDE SOIL ONE-STORY STRUCTURE TWO-STORY STRUCTURE 2000 PSF 16" WIDE x 8" THICK 20" WIDE x 8" THICK 1500 PSF 20" WIDE x 8" THICK 26" WIDE x 8" THICK THIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ON MAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHER CONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10", AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS, HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 157 3.001 January 1, 2023 S7 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BASEMENT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com & T G Y U % Q P E T G V G + P E 21$QZ 5JCMQRGG/0 GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)8'-0" OR LESS9'-0" MAX.10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 158 3.001 January 1, 2023 S8 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS VERTICAL REINFORCING TABLE Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112" CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 159 3.001 January 1, 2023 S9 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BRICK LEDGE DETAILS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com & T G Y U % Q P E T G V G + P E 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICK x 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS**** BACKFILL TYPECLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ** OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1510 3.001 January 1, 2023 S10 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS FLOOR BEARING CONNECTIONS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS* ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPE CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS** ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPECLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1511 3.001 January 1, 2023 S11 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS ANCHOR SPACING TABLES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com & T G Y U % Q P E T G V G + P E 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1512 3.001 January 1, 2023 S12 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON BEARING JOIST BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1513 3.001 January 1, 2023 S13 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON-BEARING TRUSS BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 2 1 $ Q Z 5 J C M Q R G G / 0 10'-0" MAX3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1514 3.001 January 1, 2023 S14 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WINDOW WELL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRAD E L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1515 3.001 January 1, 2023 S15 Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEPPING DOWN WALL WITH GRADE &TGYU%QPETGVG+PE 2 1 $ Q Z 5 J C M Q R G G / 0 Electric Water heater 17839 Hamburg Avenue, Lakeville HVAC Load Calculations for Country Joe Homes 22260 Dodd Blvd Lakeville, MN 5504 Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-319-4200 Wednesday, August 16, 2023 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17839 Hamburg Avenue, Lakeville Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:17839 Hamburg Avenue, Lakeville Designed By:Jake Ryan Project Date:8/16/2023 Project Comment:Portland - SOG Client Name:Country Joe Homes Client Address:22260 Dodd Blvd Client City:Lakeville, MN 5504 Client Phone:(952) 469-4066 Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-319-4200 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Southwest Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:862 CFM Per Square ft.:0.510 Square ft. of Room Area:1,689 Square ft. Per Ton:742 Volume (ft³):15,197 Building Loads Total Heating Required Including Ventilation Air:43,724 Btuh 43.724 MBH Total Sensible Gain:21,673 Btuh 79 % Total Latent Gain:5,636 Btuh 21 % Total Cooling Required Including Ventilation Air:27,308 Btuh 2.28 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17839 Hamburg Ave, Lakeville - Heat Calc.rh9 Wednesday, August 16, 2023, 11:51 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17839 Hamburg Avenue, Lakeville Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.28 742 1,689 21,673 5,636 27,308 43,724 488 862 488 862 862 System 1 Main Floor Yes 2.28 742 1,689 21,673 5,636 27,308 43,724 488 862 488 862 862 11x15 Ventilation 530 2,583 3,113 3,229 94 94 94 Supply Duct Latent 158 158 Return Duct 2,750 563 3,314 4,005 Humidification 3,574 Zone 1 1,689 18,392 2,331 20,723 32,916 488 862 488 862 862 11x15 1-Main Floor 1,689 18,392 2,331 20,723 32,916 488 862 488 862 862 7--7 F:\ ...\17839 Hamburg Ave, Lakeville - Heat Calc.rh9 Wednesday, August 16, 2023, 11:51 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17839 Hamburg Avenue, Lakeville Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size Reg Size System 1 Supply Runouts Zone 1 1-Main Floor Built-In 450 750 0.01 0.1 460.6 488 862 862 7--7 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 752 488 862 862 11x15 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:488 Cooling Flow:862 F:\ ...\17839 Hamburg Ave, Lakeville - Heat Calc.rh9 Wednesday, August 16, 2023, 11:51 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17839 Hamburg Avenue, Lakeville Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain LOWEE BUILDER GRADE: Glazing-LOWEE BUILDER GRADE, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.32, SHGC 0.32 175 4,875 0 4,477 4,477 11G: Door-Wood - Panel, U-value 0.54 20 940 0 292 292 11J: Door-Metal - Fiberglass Core, U-value 0.6 17.8 928 0 288 288 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 1497.2 8,466 0 1,587 1,587 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R49 Attic, U-value 0.02 1688.5 2,938 0 2,398 2,398 22B-10ph: Floor-Slab on grade, Vertical board insulation covers slab edge and extends straight down to 3' below grade, any floor cover, R-10 insulation, passive, heavy moist soil, U-value 0.481 190 7,951 0 0 0 Subtotals for structure:26,098 0 9,042 9,042 People:6 1,200 1,380 2,580 Equipment:1,131 4,262 5,393 Lighting:200 682 682 Ductwork:10,822 722 5,777 6,498 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 94, Summer CFM: 94 3,229 2,583 530 3,113 Humidification (Winter) 9.75 gal/day :3,574 0 0 0 Total Building Load Totals:43,724 5,636 21,673 27,308 Check Figures Total Building Supply CFM:862 CFM Per Square ft.:0.510 Square ft. of Room Area:1,689 Square ft. Per Ton:742 Volume (ft³):15,197 Building Loads Total Heating Required Including Ventilation Air:43,724 Btuh 43.724 MBH Total Sensible Gain:21,673 Btuh 79 % Total Latent Gain:5,636 Btuh 21 % Total Cooling Required Including Ventilation Air:27,308 Btuh 2.28 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17839 Hamburg Ave, Lakeville - Heat Calc.rh9 Wednesday, August 16, 2023, 11:51 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17839 Hamburg Avenue, Lakeville Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces Southwest Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Main Floor 862 909 888 827 933 *964 876 772 8--7 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°Southwest 862 21,673 5,636 2.28 45°West 909 22,686 5,634 2.36 90°Northwest 888 22,223 5,635 2.32 135°North 827 20,931 5,636 2.21 180°Northeast 933 23,194 5,633 2.40 225°East *964 *23,846 5,631 *2.46 270°Southeast 876 21,960 5,631 2.30 315°South 772 19,754 *5,637 2.12 * Indicates highest value of all rotations. 2.1 2.2 2.3 2.4 Southwest West Northwest North Northeast East Southeast SouthCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\17839 Hamburg Ave, Lakeville - Heat Calc.rh9 Wednesday, August 16, 2023, 11:52 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17839 Hamburg Avenue, Lakeville Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 24,000 25,000 26,000 27,000 28,000 29,000 30,000 31,000 32,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces Southwest Front door faces West Front door faces Northwest Front door faces North Front door faces Northeast Front door faces East Front door faces Southeast Front door faces South F:\ ...\17839 Hamburg Ave, Lakeville - Heat Calc.rh9 Wednesday, August 16, 2023, 11:52 AM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 952-215-6391 rjarvi@countryjoehomes.com Rob Jarvi Youngfield Homes Rob Jarvi Youngfield Homes 952-215-6391 rjarvi@countryjoehomes.com University of Minnesota 05/31/24 Steve Sauber 17839 Hamburg Avenue 08/16/23