HomeMy WebLinkAboutLA217897 - APPROVED - BETH HUBBARD Stamped CAD 06-29-23SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)COVER PAGE 06-28-2023 TISHANT HARSH PV-1.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 2 CIRCUITS OF 8 MODULES (16) ENPHASE IQ8PLUS-72-2-US (16) HYPERION HY-DH108P8 400B 290 VA MAX. CONT. POWER = 4.64 KWP 300 VA PEAK POWER = 4.8 KWP 6.4 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 30A BREAKER PV BACKFEED BREAKER 200A MCB WITH 200A BUSBAR WIND SPEED SNOW LOAD 50 LB/SQ.FT. TABLE OF CONTENT NO. TITLE SITE PLAN ARRAY LAYOUT STRUCTURAL ELECTRICAL LINE DIAGRAM ELECTRICAL CALCULATIONS LABELS DATASHEETS COVER PAGE PLOT PLAN ATTACHMENT PV-2.0 PV-3.0 PV-5.0 PV-6.0 PV-7.0 PV-8.0 PV - 1.0 PV - 8.0 PROJECT SITE SCALE: NTS SITE MAP PROJECT SITE SCALE: NTS VICINITY MAP PHOTOVOLTAIC SYSTEM REFERENCE CODES: APPLICABLE CODES: NEC 2020 2018 IBC 2018 IRC 2020 MINNESOTA STATE BUILDING CODE 2020 MINNESOTA RESIDENTIAL BUILDING CODE 2020 MINNESOTA STATE ENERGY CODE 2020 MINNESOTA FIRE CODE 2020 NATIONAL ELECTRICAL CODE 16458 EQUESTRIAN TRL LAKEVILLE, MN, 55044 BETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD 115 MPH Signed 6/29/2023 Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 09/13/2023jnuetzman EQUESTRIAN TRLDRIVEWAYENVOY W A Y JB(N) MAIN SOLAR UNFUSED AC DISCONNECT ROOF ARRAY (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (OUTSIDE) (N) SOLAR MODULES 3' SETBACK 18" SETBACK (N) ENPHASE IQ COMBINER PANEL (N) NEMA 3R RATED TRANSITION BOX N U CP M S P UA C P M (N)PRODUCTION METER SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)SITE PLAN 06-28-2023 TISHANT HARSH PV-2.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401PROJECT SITE SCALE: NTS SITE MAP SCALE: NTS SITE PLAN PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 2 CIRCUITS OF 8 MODULES (16) ENPHASE IQ8PLUS-72-2-US (16) HYPERION HY-DH108P8 400B 290 VA MAX. CONT. POWER = 4.64 KWP 300 VA PEAK POWER = 4.8 KWP 6.4 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 30A BREAKER PV BACKFEED BREAKER 200A MCB WITH 200A BUSBAR ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2" X 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY 1 33°121°16 NOTE : PROVIDING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA, WHEN THE ARRAYS TAKE LESS THAN 33% WE CAN JUSTIFY 18" SETBACKS FROM RIDGE ROOF COVERAGE AREA CALCULATION AREA OCCUPIED ON ROOF PERCENTAGE OF TOTAL ARRAY TOTAL AREA OF ARRAY TOTAL AREA OF ROOF 3132.21 SQ. FT 336.31 SQ. FT 10.74% Signed 6/29/2023 11'-2"34'-5"3'1'-6"ROOF N3' SETBACK 18" SETBACK SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)ARRAY LAYOUT 06-28-2023 TISHANT HARSH PV-3.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401- VENT, ATTIC FAN (ROOF OBSTRUCTION) - MOUNTS - COUPLING LEGEND - ROOF SETBACK 45'-7"6"SCALE: NTS SIDE ELEVATION SCALE: NTS ARRAY LAYOUT PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 2 CIRCUITS OF 8 MODULES (16) ENPHASE IQ8PLUS-72-2-US (16) HYPERION HY-DH108P8 400B 290 VA MAX. CONT. POWER = 4.64 KWP 300 VA PEAK POWER = 4.8 KWP 6.4 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 30A BREAKER PV BACKFEED BREAKER 200A MCB WITH 200A BUSBAR ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2" X 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY 1 33°121°16 Signed 6/29/2023 N EQUESTRIAN TRLDRIVEWAYENVOY W A Y JBU (N) MAIN SOLAR UNFUSED AC DISCONNECT ROOF ARRAY (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (OUTSIDE) (N) SOLAR MODULES 3' SETBACK 18" SETBACK (N) ENPHASE IQ COMBINER PANEL (N) NEMA 3R RATED TRANSITION BOX 120' - 1 0 "96'-3"1 2 1 ' - 6 "56'-7"48' - 8 "23'-7"48' - 8 "15'-1"15 ' - 6 "5'-9"5'-5"22'- 1 1 "10'-4"PROPERTY LINE CP MS P UA C PM (N)PRODUCTION METER SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)PLOT PLAN 06-28-2023 TISHANT HARSH PV-4.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401SCALE: 1"=10' PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 2 CIRCUITS OF 8 MODULES (16) ENPHASE IQ8PLUS-72-2-US (16) HYPERION HY-DH108P8 400B 290 VA MAX. CONT. POWER = 4.64 KWP 300 VA PEAK POWER = 4.8 KWP 6.4 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 30A BREAKER PV BACKFEED BREAKER 200A MCB WITH 200A BUSBAR ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2" X 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY 1 33°121°16 PLOT PLAN Signed 6/29/2023 28'-4" 7'-4"7'-4" 1/2" OSB WITH ASPHALT SHINGLES ROOF TRUSSES 2"X4" @ 24" O.C. ROOF ATTIC 7'-4" 33° 1'-6" SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)STRUCTURAL 06-28-2023 TISHANT HARSH PV-5.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401ROOFSCALE: NTS KEY PLAN PV MODULE FOOT SPACING IS 48" O.C. ACROSS PANEL WIDTH WITH 2 ROWS PER MODULE TYPICAL LAYOUT PROVIDES AN AVERAGE OF 1.6 FEET PER MODULE. MODULE WEIGHT DISTRIBUTED PER MOUNTING FOOT = 52.48 LBS./1.6 FEET = 32.8 LBS./MTG. FOOT. MODULE = 52.48 LBS. OVER 21.015 SQ.FT. = 2.497 LBS/SQ.FT. AREA = 67.79" x 44.64" NOMINAL (21.015 SQ.FT.) WEIGHT = 52.48 LBS. MOUNTING LOAD CALCULATION SMART SLIDE #12 WOOD SCREWS 2 PER MOUNTS MINIMUM OF 2" EMBEDMENT ROOF FRAMING ROOF DECKING SCALE: NTS ATTACHMENT DETAILS SCALE: NTS ATTIC DETAILS PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 2 CIRCUITS OF 8 MODULES (16) ENPHASE IQ8PLUS-72-2-US (16) HYPERION HY-DH108P8 400B 290 VA MAX. CONT. POWER = 4.64 KWP 300 VA PEAK POWER = 4.8 KWP 6.4 KWP ROOF SPECIFICATION ROOF TYPE ROOF CONDITION FRAMING SHEATHING 1/2" OSB COMPOSITE SHINGLE GOOD TRUSSES: 2" X 4" @ 24" O.C. ARRAY SPECIFICATION ROOF NO.TILT AZIMUTH QTY 1 33°121°16 RACKING SPECIFICATION MIN/MAX ROOF SLOPE MAX ANCHOR SPACING (35MM/40MM) MAX ANCHOR SPACING (32MM) MAX MODULE SIZE MODULE CANTILEVER 1/2:12 / 12:12 48" 67.79" X 44.64" X 1.18" MAXIMUM CANTILEVER IS 1/3 BRACKET SPACING WEIGHT (INCLUDING FRAME) MODEL FORMAT MODULE SPECIFICATION HY-DH108P8 400B 67.79" ~ 44.64" ~ 1.18" 52.48 LBS GENERAL NOTES 1.SOLAR PANELS SHALL NOT EXCEED ANY PART OF ROOF EDGE OR PEAK. Signed 6/29/2023 === NEMA3R RATED JUNCTION BOX: SHALL COMPLY W/ NEC 110.3 2P - 20A 2P - 20A ENVOY-IQ MONITOR === ENPHASE MICRO-INVERTER ENVOY BREAKER (N) 240V/80A PV ENPHASE PV LOAD CENTER, AC COMBINER WITH INTEGRATED MONITORING, NEMA 3R RATED MANUFACTURER INSTALLED 1 1 THE ENPHASE MICRO-INVERTERS HAVE INTEGRATED GROUND AND DOUBLE INSULATION, SO NO GEC OR EGC IS REQUIRED. THE DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENTS OF NEC 7 8 7 8 CIRCUIT 2 : 8 MODULES CIRCUIT 1 : 8 MODULES (N) AC DISCONNECT 240V/ NEMA 3R VISIBLE-LOCKABLE LABELED 30A (N) MAIN DISCONNECT UTILITY SERVICE 120/240V SINGLE PHASE L1 G N-G (E) LOADS OUTSIDE HOUSE INSIDE HOUSE PV BREAKER NEEDS TO BE INSTALLED AT FARTHEST FROM THE MCB (E) RATED MAIN SERVICE PANEL GROUNDING 200A 200A 30A PV PRODUCTION METER MBOTTOM TOP PV PRODUCTION METER MILBANK U4518-XL-W 200A,600V SINGLE PHASE FORM 2S THIS PRODUCTION METER SOCKET NEEDS TO BE INSTALLED WITHIN 10 FT OF UTILITY METER NAME : GREG MARTIN LICENSE NO:49518 SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)ELECTRICAL LINE DIAGRAM 06-28-2023 TISHANT HARSH PV-6.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401SCALE: NTS ELECTRICAL LINE DIAGRAM PROPOSED SYSTEM SPECIFICATION SYSTEM SIZE DC SYSTEM SIZE AC SYSTEM SIZE AC MODULES USED INVERTER USED BRANCH CIRCUIT RACKING ECOFASTEN ROCKIT + SMART SLIDE 2 CIRCUITS OF 8 MODULES (16) ENPHASE IQ8PLUS-72-2-US (16) HYPERION HY-DH108P8 400B 290 VA MAX. CONT. POWER = 4.64 KWP 300 VA PEAK POWER = 4.8 KWP 6.4 KWP ELECTRICAL SPECIFICATION SERVICE PANEL INTERCONNECTION PV OCPD 30A BREAKER PV BACKFEED BREAKER 200A MCB WITH 200A BUSBAR CONDUIT TAG QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE A -NA NA B #10AWG THWN-2 PVC, EMT OR FLEX IN ATTIC 1"(1)#6AWG THWN-2 GND C (3)THWN-2 PVC, EMT OR FLEX IN ATTIC 1"(1)#6AWG THWN-2 GND D (1)#6AWG BARE GROUND NA NA (2) (4) #10AWG ENPHASE IQ CABLE NAME : GREG MARTIN LICENSE NO:49518 SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)ELECTRICAL CALCULATION 06-28-2023 TISHANT HARSH PV-7.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC 13.79 A 37.07 V 12.9 A 31.01 V HYPERION HY-DH108P8 400B TEMPERATURE DETAILS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%) -26° 32° MANUFACTURER MODEL NO. MAX DC INPUT VOLTAGE MAX CONTINUOUS OUTPUT POWER PEAK OUTPUT POWER NOMINAL AC OUTPUT VOLTAGE MAX CONTINUOUS OUTPUT CURRENT INVERTER SPECIFICATIONS 1.21 A 240 V ENPHASE IQ8PLUS-72-2-US 60 V 290 VA 300 VA CONDUCTOR AMPACITY BEFORE COMBINER PANEL: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC CIRCUIT CONDUCTOR SIZE TEMP. CORRECTION PER TABLE CIRCUIT CONDUCTOR AMPACITY NEC CODES 310.15(B)(2)(a) 310.15(B)(3)(a) 310.15(B)(16) - - 32° 0.96 4 0.8 10 AWG 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY 1.25 X MAX OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC 690.8(A&B) NEC TABLE 310.15(B)(2)(a) 310.15(B)(16) 310.15(B)(3)(a) 26.88A 12.1A CONDUCTOR AMPACITY AFTER COMBINER PANEL: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION CIRCUIT CONDUCTOR SIZE TEMP. CORRECTION PER TABLE CIRCUIT CONDUCTOR AMPACITY NEC CODES 310.15(B)(2)(a) 310.15(B)(3)(a) 310.15(B)(16) - - 35A 10 AWG 1 3 0.96 32° 1.25 X (TOTAL NUMBER OF INVERTERS X INVERTER MAX CONTINUOUS OUTPUT CURRENT) REQUIRED CIRCUIT CONDUCTOR AMPACITY DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC 690.8(A&B) NEC TABLE 310.15(B)(2)(a) 310.15(B)(16) 310.15(B)(3)(a) SELECTED OCPD NEC 240.6(A) 24.2A 33.6A 30A ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE THIS SYSTEM IS EQUIPPED WITH RAPIDSHUTDOWN ROOFTOP INVERTERS WILL DE-ENERGISE AT SERVICE PANEL OUTAGE NOTICE SOLAR AC DISCONNECT LABELS DUAL POWER SOURCE WARNING AC COMBINER LABELS SERVICE PANEL LABEL TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN PHOTOVOLTAIC AC SOURCE CAUTION THIS IS MAIN 2 OF 2 WITH MAIN 1 OF 2 LOCATED INSIDE WARNING AC COMBINER AND DATA AQUISITION. DO NOT ADD LOADS. DO NOT TOUCH TERMINALS.LINE AND LOAD SIDE MAY BE ENERGIZEDIN OPEN POSITION. NOTICE NOTICE THIS IS MAIN 1 OF 2 WITH MAIN 2 OF 2 LOCATED ADJACENT THIS SERVICE IS ALSO SERVED BY A PV SYSTEM WITH RAPID SHUTDOWN. INVERTERS LOCATED ON ROOF AUTO DE-ENERGISE WHEN SOLAR SERVICE MAIN IS IN OPEN POSITION.THE DC CONDUCTORS OF THE PV SYSTEM ARE UNGROUNDED AND MAY BE ENEGIZED.IF BACKFEED BREAKER PRESENT DO NOT RELOCATE THIS OVERCURRENT DEVICE. DO NOT DISCONNECT UNDER LOAD DUAL POWER SOURCES. SECOND SOURCE IS PV SYSTEM !WARNING! DUAL POWER SUPPLY. SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM THIS SERVICE PANEL IS ENERGIZED FROM MORE THAN ONE SOURCE.ONLY AUTHORIZED PERSON WHO ARE FAMILIAR WITH THIS SYSTEMSHOULD ATTEMPT TO DO SERVICE WORK ON IT. !WARNING! !WARNING!WARNING CAUTION !WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD UTILITY AC DISCONNECT PV AC DISCONNECT NOTICE RAPID SHUTDOWN DISCONNECT SWITCH !WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ELECTRIC SHOCK HAZARD BI-DIRECTIONAL METER 2137 ROUTE 35 HOLMDEL, NJ 07733 TEL: (732) 979-2400www.suntuity.com UTILITY METER LABELS CONDUIT LABELS DIRECTORY LABEL AS PER NEC 705.10 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAY WITH SAFETY DISCONNECTS AS SHOWN: CAUTION: MULTIPLE SOURCES OF POWER N U CP MS P UA C PM NAME : GREG MARTIN LICENSE NO:49518 SHEET NAME DATE DRAWNDESCRIPTIONREVISIONSSignature with Seal PROJECT NAME & ADDRESS DRAWN BY REVIEWED BY SHEET NO.REV BYREVDRW BYDATEBETHANY HUBBARD/GARY L HUBBARD JR/BETH HUBBARD16458 EQUESTRIAN TRLLAKEVILLE, MN, 55044(Lat, Long: 44.710899, -93.174054)LABELS 06-28-2023 TISHANT HARSH PV-8.02137 Route 35Holmdel, NJ 07733Tel:(732) 979-2400Fax: (732) 979 -2401(E)UTILITY METER (N)MAIN SOLAR UNFUSED AC DISCONNECT (N)ENPHASE IQ COMBINER PANEL (E)MAIN SERVICE PANEL (INSIDE) SOLAR MODULES (N)PRODUCTION METER warranty for materials and workmanship warranty for extra linear power output 12Years 30Years ©Copyright 2023 HYPERION HY-DH108P8B-US-V1.7 IEC61215 / IEC61730 / UL61730IEC61701 / IEC62716 / IEC60068 ISO9001 info@hyperion-usa.com American Hyperion Solar LLC. 2880 Zanker Road, Suite 203, San Jose, CA 95134 395-415W MADE IN THAILAND HY-DH108P8B 108 HALF-CELL BIFACIAL MODULE High Conversion Efficiency Module efficiency up to 21.3%through advanced cell technology and manufacturing process Excellent Weak Light Performance More power output in weak light condition such as cloudy days,morning and sunset Extended Mechanical Performance Module certified to withstand extreme wind (2400 Pa and snow loading (5400 Pa Pa Quality Guarantee High module quality ensureslong-term reliability 98% 97% 84.95% 80.2% +3.25% +5.75%+7.00% 1 5 10 15 302025 +4.50% Conventional Module Hyperion Performance +2.00% Warranty partner HY-DH108P8B-395/415 1086±2 (42.76±0.08)30±1(1.18±0.04)860±1 (33.86±0.04)1360±1 (53.54±0.04)1722±2 (67.80±0.08)1134±2 (44.65±0.08) 33 (1.30)30 (1.18)A B AA-A Frame Section B Installation Hole9 (0,35)14 (0.55) Unit: mm (inch) BLACK DH108P8B Solar Cell No. of Cells Dimensions Weight Junction Box Output Cables Connector Back Cover Operating Temperature Max. System Voltage Max. Fuse Rating Frontside Max. Loading Bifaciality Fire Resistance DC 1500V (IEC/UL) Backside Max. Loading -40°C ~ +85°C(-40°F ~ +185°F) 30A 5400Pa (112lb/ft²) 2400Pa (50lb/ft²) 70%±10% IEC Class A, UL Type 29 395 30.84 12.81 36.98 13.70 20.2% Front Cover ©Copyright 2023 HYPERION HY-DH108P8B-US-V1.7www.hyperion-solar.com 310.2 29.82 10.40 35.39 11.25 306.4 29.60 10.35 35.31 11.19 302.5 29.41 10.29 35.15 11.13 298.8 29.25 10.22 35.07 11.05 42 ± 2 °C -0.35%/°C -0.27%/°C 0.05%/°C 45 ± 2 °C 405 400 31.21 12.98 37.23 13.87 410 31.45 13.04 37.32 13.95 21.0% 31.01 12.90 37.07 13.79 20.7% 20.5% Current-Voltage & Power-Voltage Curve (410W) 0 ~ +5 2.0mm(0.079in.) semi-tempered AR glass Mechanical Parameters Engineering Drawing Mono PERC 182mm 108 (6 × 18) 1722 × 1134 × 30mm (67.80 × 44.65 × 1.18in.) 23.8kg (52.47lbs) IP68 rated (3 bypass diodes) 4mm² (IEC),12 AWG(UL)(-/+)1200mm (47.24in.) or customized QC4.10 or similar 2.0mm(0.079in.) semi-tempered glass Container 36 pcs/Pallet, 792 pcs/40’HC Operating Parameters Electrical Characteristics - STC Maximum Power at STC (Pmax/W) Power Tolerance (W) Optimum Operating Voltage (Vmp/V) Optimum Operating Current (Imp/A) Open Circuit Voltage (Voc/V) Short Circuit Current (Isc/A) Module Efficiency Electrical Characteristics - NMOT Maximum Power at NMOT (Pmax/W) Optimum Operating Voltage (Vmp/V) Optimum Operating Current (Imp/A) Open Circuit Voltage (Voc/V) Short Circuit Current (Isc/A) Temperature Characteristics Nominal Module Operating Temperature Nominal Cell Operating Temperature Temperature Coefficient of Pmax Temperature Coefficient of Voc Temperature Coefficient of Isc Rearside Power Gain Maximum Power (Pmax/W) Irradiance 800 W/m², ambient temperature 20 °C, AM1.5, wind speed1m/s. Irradiance 1000 W/m², ambient temperature 25 °C, AM1.5. Rearside Power Gain (Reference to 415WFront) Optimum Operating Voltage (Vmp/V) Optimum Operating Current (Imp/A) Open Circuit Voltage (Voc/V) Short Circuit Current (Isc/A) Module Efficiency 5% 436 31.61 13.79 37.45 14.72 22.3% 15% 477 31.71 15.05 37.55 16.08 24.4% 25% 519 31.71 16.36 37.55 17.48 26.6% 415 31.61 13.13 37.45 14.02 21.3% 313.9 29.98 35.51 11.31 10.47 IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s rst microgrid-forming, software- dened microinverters with split-phase power conversion capability to convert DC power to AC power eciently. The brain of the semiconductor-based microinverter is our proprietary application-specic integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or o-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redene reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PVRapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Congurable to support a wide range of grid proles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SP-DS-0002-01-EN-US-2021-10-19 DATASHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/ module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current2 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.5 97.6 CEC weighted efficiency %97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-DS-0002-01-EN-US-2021-10-19 X-IQ-AM1-240-4 The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 4/4C X-IQ-AM1-240-4 X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com Data SheetEnphase Networking Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed X-IQ-AM1-240-4CX-IQ-AM1-240-4C X-IQ-AM1-240-4 X-IQ-AM1-240-4CX-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 10-21-2021 MODEL NUMBER IQ Combiner 4 (X-IQ-AM1-240-4)IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C)IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for Ensemble sites- 4G based LTE-M1 cellular modem with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 65 A Max. continuous current rating (input from PV/storage)64 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT)A pair of 200 A split core current transformers MECHANICAL DATA Dimensions (WxHxD)37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductorsAlways follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 4/4C © 2018 Schneider ElectricAll Rights Reserved 3-3 schneider-electric.us Light Duty Safety Switches Class 3130 / Refer to Catalog 3100CT1602 Light Duty—Visible Blades 10 kA Short Circuit Current Rating L221N The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces, and garages. The light duty safety switch has visible blades and a ground lug as standard features. Table 3.1: Fusible System Amperes Fuse NEMAType 1 IndoorCat. No. Horsepower Ratings 120 Vac 240 Vac Std. Max.Std. Max. 1Ø 1Ø 1Ø 1Ø 2 Wire (1 Blades and Fuseholders, 1 Neutral)—120 Vac 30 Plug L111N — ——— 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac 30 Plug Cart L211N L221N 1/2 1/2 2 2 1-1/2 1-1/2 3 3 General Duty—Up To 100 kA Short Circuit Current Rating General duty safety switches are designed for residential and commercial applications where durability and economy are prime considerations. Typical loads are lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factory or field-installed neutral assembly or a field-installed service grounding kit, (see page 3-5) as applicable. General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1. 240 Volt—Single Throw Fusible Switches D223N Table 3.2: Fusible System Amperes Fuse NEMA Type 1 Indoor NEMAType 3R[1]Rainproof Class RFuse Kits[2] Horsepower Ratings Std. (Fast ActingOne-Time Fuses) Max. (DualElementTime-DelayFuses) Cat. No. Cat. No. Cat. No. 1Ø 3Ø 1Ø 3Ø 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac  30 Plug Use Light Duty Device for this Application (see above) — — — —  30 Cart. Use three-wire devices for thisapplication.— — — — 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum  30 Plug D211N D211NRB —  1-1/2 —  3 —  30 Cart.D221N D221NRB DRK30  1-1/2 3[3] 3  7-1/2 [3]  60 Cart.D222N D222NRB RFK03H  3 7-1/2[3]10 15[3] 100 Cart.D223N D223NRB RFK10  7-1/2 15[3]15 30[3] 200 Cart.D224N [4]D224NRB[4]HRK1020 15 25[3]—60[3] 400 Cart.D225N D225NR DRK40 — — — — 600 [5]Cart.D226N D226NR DRK600 — — — — 4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum  30 Cart.D321N D321NRB DRK30  1-1/2   3  3   7-1/ 2  60 Cart.D322N D322NRB RFK03H  3 7-1/2[6]10 15[6] 100 Cart.D323N D323NRB RFK10  7-1/2 15[6]15 30[6] 200 Cart.D324N[4]D324NRB[4]HRK1020 15 25[6]—60[6] 400 Cart.D325N D325NR DRK40 —  50 — 125 400 [7]Class T D325NT D325NTR — —  50 — — 600 [5]Cart.D326N D326NR DRK600 —  75 — 150 600 [7]Class T D326NT D326NTR — —  75 — — 800 [7]Class T T327N T327NR — — 100 — —3SAFETY SWITCHES [1]Bolt-on hubs —Refer to Rainproof Bolt-On Hubs,Table 1.27, page 3-14. [2]When properly installed, the Class R Fuse Kit rejects all but Class R fuses. [3]For corner grounded delta systems only. Use switching poles for ungrounded conductors. See data bulletin 2700DB0202 for additional information. [4]For 200% neutral, order (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI. [5]Order Class J Fuse Kit GDJK600 if using Class J fuses. [6]If corner grounded delta, use outer switching poles for ungrounded conductors. [7]D325NT, D325NTR, D326NT, D326NTR, T327N and T327NR accept only 300Vac Class T fuses. 08/06/2018 3-4 © 2018 Schneider ElectricAll Rights Reserved General Duty Safety Switches General Duty—Up to 100 kA Short Circuit Current Rating schneider-electric.usClass3130/ Refer to Catalog 3100CT1602 240 Volt—Single Throw Non-Fusible Switches Table 3.3: Non-Fusible System Amperes NEMAType 1 Indoor NEMAType 3RRainproof[8]Horsepower Ratings(Max.) Cat. No.Cat. No.1Ø 3Ø 2 Wire (2 Blades)—240 Vac Maximum  30 —DU221RB  3 —  60 —DU222RB 10 —  60 QO260NATS [9] [10]QO200TR [9] [10] [11]10 — 100 QO2000NS [9] [10]QO2000NRB [9] [11]20 — 200 Use 3P Switch Use 3P Switch —— 400 Use 3P Switch Use 3P Switch —— 600 Use 3P Switch Use 3P Switch —— 3 Wire (3 Blades)—240 Vac Maximum  30 DU321 DU321RB  3   7-1/2  60 DU322 DU322RB 10  15 100 DU323 [12]DU323RB [12]15  40 200 DU324 [13]DU324RB [13]15  60 400 DU325 —— 125 600 DU326 [14]—— 150 UL Listed Maximum Short Circuit Current Ratings — AC Only Table 3.4: Fusible Safety Switch Short Circuit Current Rating Fuse Class UL Listed Short Circuit Rating Plug 10 kA H, K 10 kA J [15], R 100 kA T [16]100 kA Non-Fusible Safety Switches Systems equal or less than 10 kAIR SCCR —Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with a non-fusible safety switch. Systems above 10 kAIR SCCR—The UL Listed short circuit current rating for Square D non-fusible switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.5: Non-Fusible Safety Switch Short Circuit Current Rating Fuse Class or Circuit Breaker Type[17]UL Listed Short Circuit Rating Any Brand Circuit Breaker 10 kA H or J PowerPact Circuit Breaker Up to 65 kA [18] H, K 10 kA J, R 100 kA [19] T 100 kA [20]3SAFETY SWITCHES [8]Bolt-on hubs—Refer toHubs, page 3-14. [9]Enclosed molded case switch—Refer to Section 1. [10]Includes factory-installed grounding kit. [11]Not service entrance rated—Refer to Table 3.34 for more information. [12]If a neutral assembly is required, order and field install SN0610. [13]If a neutral assembly is required, order and field install a SN20A Neutral Assembly Kit. For a 200% neutral application, order and field install (2) SN20A Neutral Assembly Kits and (1) SN20NI Neutral Jumper Kit. [14]If a neutral assembly is required, order and field install D600SN. [15]Only applicable to 200 A - 600 A except D325NT, D325NTR, D326NTand D326NTR. [16]Only applicable to D325NT, D325NTR, D326NT, D326NTR, T327N and T327NR. [17]Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. [18]Only applicable to DU324 and DU324RB. HD, JD = 25 kA maximum. [19]SCCR = 50 kA, applicable to DU222RB, DU322 and DU322RB. [20]Only applicable to DU323, DU323RB, DU325 and DU326. 08/06/2018 VERSION: v2.8REVISION DATE: 03/2/22 INSTALLATION GUIDEINSTALLATION GUIDE RATINGSPAGE 05 TORQUE SPECIFICATIONS Class A System fire rating with Type 1  P9 modules. Any module-to-roof gap is permitted, with no skirt required. UL 2703 MARKING EXAMPLE: System components should be periodically re-inspected for loose components, loose fasteners, and corrosion such that if found, the a΍ected components are to be immediately replaced. RATINGS Fire Ratings*Class A System Fire Rating Max System Voltage 1500V Max Fuse Rating 40A Certification Conforms to UL STD 2703 Markings Product listing label is located on RockIt Mount Roof Pitch 2:12 - 12:12 UL 2703 Allowable Design Load Rating 30 psf downward, 30 psf upward and 20 psf lateral Max Module Size 24 sq. ft. Maximum Cantilever 1/3 of span Maximum Span 6 ft Landscape, 4 ft Portrait Multiple use Rated Components (Position Independent)RockIt Mount, RockIt Coupling & MLPE Module Mount Component Torque (in-lb)Notes Lag Screws N/A Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. Mount 200 Coupling 200 Steel Slide Screw N/A Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. MLPE Module Mount 144 Ground Lug N/A Refer to specific ground lug manufacturerȇs installation manual RockIt Pedestal Screw 150 ROCKIT SYSTEM MFG ID CODE: SSS-QQ-YYYY Conforms to UL STD 2703 TM XXXXXXX VERSION: v2.8REVISION DATE: 03/2/22 INSTALLATION GUIDEINSTALLATION GUIDE GROUNDINGPAGE 20 THERMAL EXPANSION & BONDING • A thermal expansion gap is required per each continuous 40’ length of modules. • Omit a coupling and leave a 2” gap in the RockIt array skirt and also between the modules at that point. • Bonding across the thermal gap should be accomplished with an approved ground lug for each array and an equipment grounding conductor. BONDING PATH & ASSEMBLY • RockIt mount bonds N-S rows of modules. • RockIt coupling bonds E-W rows of modules. • RockIt array skirt is bonded to the array via the RockIt mount. • One approved ground lug is required per continuous PV array. BONDING AND GROUNDING Bond Path Grounding Lug Equipment GroundingConductor (EGC) RockIt Coupling RockIt Mount RockIt Array Skirt Bond Path Grounding Lug Equipment GroundingConductor (EGC) RockIt Coupling RockIt Mount RockIt Array Skirt VERSION: v2.8REVISION DATE: 03/2/22 INSTALLATION GUIDEINSTALLATION GUIDE GROUNDINGPAGE 21 NECESSARY COMPONENTS One of the following grounding lugs (or any UL 2703 Compliant ground Lug): • Burndy CL50-1TN Ground Lug (UL2703 - E3514343 / UL 467 - E9999) • ILSCO SGB-4 Ground Lug (UL2703 - E354420/ UL 467 - E34440) • ILSCO GBL-4DBT (UL2703 - E354420 / UL 467 - E34440) • ILSCO GBL-4DBTH (UL2703 - E354420 / UL 467 - E34440) • ILSCO GBL-4SS (UL2703 - E354420 / UL 467 - E34440) INSTALLATION • Insert the flange bolt into the module ground hole. Place Star Washer over bolt. Place ground lug over the bolt and Star Washer, and turn to desired orientation. • Install Flange Nut. • Tighten Flange Nut/Bolt. • Place wire in Ground Lug channel and tighten set screw to complete assembly. BONDING AND GROUNDING Above: Optional Location for grounding lug on last row upslope of array *Equipment grounding wire should be sized in accordance with the National Electrical Code, NFPA70 and a minimum of 1/4” clearance is required between bare copper wires and aluminum components. INTRODUCING ROCKIT SMART SLIDE! ROCKIT SMART SLIDE • Eliminates the need to pry up shingle courses and install a metal flashing • Multiple opportunities to find the rafter • Eliminates the need to drill pilot holes • No need for additional material when architectural shingles are not level • Longer 6.75” slide avoids overlaps in shingle courses • Integrated flashing utilizes UltraGrip Technology™ to create a watertight seal Introducing EcoFasten’s patent pending RockIt Smart Slide, our simple solution for quickly installing the popular RockIt rail-less racking system to composition shingle roofs. Features & Benefits Required Components: ECOFASTENSOLAR.COM Part Number:Description: 2011024 RI SMART SLIDE BLK 6.75” 2011025 RI SMART SCRW #12X3” W/BW ROCKIT SMART SLIDE 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 1-877-859-3947 | INFO@ECOFASTENSOLAR.COM VERSION 1.2Integrated UltraGrip Technology™ Pre-installed sealing pads are compatible with all composition shingle roofs and can be installed in ambient temperatures as low as 5 degrees. The compression achieved when fastened to the roof creates a super strong watertight seal. In most cases, Smart Slide can be installed to the roof without the need for sealant. A layer of flexible foam provides cushioning, which allows the super- sticky waterproofing sealant to embed deep into the granules of the shingle as well as to flexibly conform over the steps found on architectural-style shingles. Testing & Documentation • UL441 Rain Report • TAS 100 (A)-95 Wind and Wind Driven Rain Resistance • Mechanical Load Test/Structural Capacity Certification • Florida Product Approval • RockIt Installation Manual • RockIt CutSheets A layer of flexible foam pushes the sealant deep into the shingle granules and around shingle steps RockIt Smart Slide can be installed on top of architectural shingles steps JB-1.XLSpecification SheetPV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: 120 Amps • Allowable Wire: 14 AWG – 6 AWG • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 – 12:12 • Max Side Wall Fitting Size: 1” • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.XL: UL1741 - Approved wire connectors: must conform to UL1741 • System Marking: Interek Symbol and File #5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. A. System Specifications and Ratings Phone: 385-202-4150 | www.ezsolarproducts.com